Ethernet Media. Introduction Quick Selection Ethernet Media. Systems. PannelConnect Connection. Connection. Safety.

Similar documents
10 million cycles at 20 x diameter (TPE cable)

Ethernet Media. Introduction Quick Selection Ethernet Media. Systems. PannelConnect Connection. Connection. Safety.

Contents 9-1. Network Media

10 million cycles at 20 x diameter (TPE cable)

Ethernet Media. Technical Data. Bulletin Numbers 1585, 1585A, 1585BP, 1585BT, 1585BX, 1585BZ, 1585D, 1585J

Ethernet Media. Technical Data. Cable Spools 2. Cordsets & Patchcords 5. Patchcords & Field Attachables 12

Ethernet Media. Technical Data. Cable Spools 2. Cordsets & Patchcords 5. Patchcords & Field Attachables 10

10 million cycles at 20 x diameter (TPE cable)

Industrial Ethernet Media

AC Micro Style Cordsets and Receptacles

BUS UNITRONIC BUS DeviceNet Gray

Complete the Installation SKINTOP MS-SC. Color Code: Approvals: Nominal Outer Diameter

Complete the Installation SKINTOP MS-SC. Approvals: Approx. SKINTOP Part

DeviceNet Media System

PRODUCT INFORMATION. ETHERLINE Cat.5e FLEX. Info Industrial Ethernet cable Cat.5e Only for patch cable applications (max. 60 m)

M12 connector D-coding M12 connector X-coding RJ45 IP20 connector PushPull RJ45 IP65 / IP67 connector

Never Beaten by Seasons

9/27/04 cci Cablecom Inc. 1

Better all-round. DataVoice Circular connectors STX M12x1 IP67 Connector series for industrial applications. PoE+ 10 GBE. coded.

07. har-link Interface Connectors

CONEC Industrial Ethernet Circular Sealed RJ45 Connector System consists of a RJ45 Plug Kit, a Receptacle Kit and a Protective Cover Assembly.

EtherNet Physical Media Connectivity

Standard Buccaneer - Ethernet

Detailed Specifications & Technical Data

PRODUCT INFORMATION. ETHERLINE Cat.5e. Info Industrial Ethernet cable Cat.5e

New Product Bulletin. Lumberg Automation EtherNet/IP Modules for Industrial Automation Applications

µcom-10gb + MAIN FEATURES FEATURES AND BENEFITS MARKETS & APPLICATIONS Harsh Environment 10Gb Ethernet Micro Connectors Amphenol Socapex

Marker Tags. End anchor J Screw Type

Data sheet C6 A modul 90 jack

The Field Guide for Industrial Ethernet FIELD GUIDE

Data sheet C6 A modul 1 port 180 M AP pure white

Sensor Connectivity Introduction Global Plus Connector Cables Multi-Connector Blocks. Product Selection Guide...

µcom-10gb + Amphenol MAIN FEATURES FEATURES AND BENEFITS MARKETS & APPLICATIONS Harsh Environment 10Gb Ethernet Micro Connectors

We offer a complete portfolio of industrial-grade Ethernet physical media specifically designed for use in harsh environments. DC Micro Patchcord

AMP NETCONNECT EtherSeal System Bringing Ethernet and Structured Cabling to Non-Office Environments.

Detailed Specifications & Technical Data

6000 Series Buccaneer

DeviceNet Physical Media

CC-Link. Simple communication programming - configuration software available but not required

ArmorConnect Power and Control Media

Quick Selection Guide... page 11-2 Products

Ethernet Series. Etherplug Etherlink V Etherlink V Specifications Ethernet Series

Contents RFID. 57RF Handheld Interfaces and Spacers... page RF Cables... page 11--7

April 2017 Rev 1

BCC Part Number Matrix Breakdown Balluff cables, cordsets & connectors for industial automation equipment

Innovative system solutions flexible connection technology

Industrial Ethernet Panel-Mount Adaptors for PROFINET or EtherNet/IP Applications

Cat.8 Shielded Field Termination Plug Description

M12x1 Circular Connectors

Type Qty. Order No. IE-PI-HYB-10P

Bulletin 280/281 ArmorStart Distributed Motor Controller. DeviceNet Media

Standard Buccaneer - Ethernet

Inductive Proximity Sensors

ArmorStart Distributed Motor Controllers

TIA-1005-A M.I.C.E Rated Product Selection Guide

Standard Analog Video Cable 75 Ohm Miniature Coax

Data sheet. Connection line M12 8-pole X-coded 2.0 m. Illustrations P/N 142M2X11020 EAN Product specification. Page 1/

IP68 Sealed - Mini USB Buccaneer

LP-4CEUSXX Cat 5e Unshielded U/UTP Patch Cords

6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding

RJF RB Ethernet connection system for harsh environment Industrial Ethernet

Ethernet cabling. B Ethernet cabling. Ethernet cabling overview B 2. Cabling 4-poles IP 20 B.1 8 IP 65 / IP 67 B Cables B Tools B.

M12 Field Wireable Connectors. M12 CAT.6A Field Wireable Connectors. M12 Field Wireable Connectors for PROFINET

HELUKABEL YOUR ONE-STOP SOLUTION PROVIDER! Data, Network & Bus Technology. Industrial Ethernet Cables Connectors Tools Pre-assembled Parts

121700A Paired - Category 5e DataTuff Twisted Pair Cable

Product information Patch Cord Cat. 6A, S/FTP, 4P, LSFRZH, gray, RJ45/s- RJ45/s, 1.0 m

Communication Wiring Color Codes

Compact Module. Category 6 UTP Cabling System

ATM SERIES ATM Series

Screened highly flexible data transmission cable with PUR outer sheath and twisted pairs - UL/CSA-listed

Modular plugs, accessories and tooling

Brad Nano-Change M8 Sensor/Actuator Connectivity

Industrial Ethernet Cordsets including PROFINET

AUTOMOTIVE AUTOMATION & ELECTRICAL SOLUTIONS

Data sheet. 25Gmodul. Illustrations P/N 130B11-25-E EAN Product specification. Page 1/ Dimensional drawing

SAC-5P-MS/ 1,0-920/FS SCO

Amphenol LTW Innovation in Waterproof Solution

Screened highly flexible data transmission cable with PUR outer sheath and twisted pairs - UL/CSA-listed

Connectivity Solutions Contents

EPIC Circular Connectors CIRCON M23 Series

Field-terminated RJ45 connector with housing. Color housing: gray (RAL 7042). Color termination block: red.

Application Note AN114

Telephony Multi-Taps. 9000T-TP Series

BVS UR E Ordering code: BVS001H

PATCH CABLE 132 WIR SORGEN FÜR VERBINDUNG

Data sheet C6 A modul 2 port 180 M UP pure white

Rugged USB Solutions USB3.0

Connecting cables, Ethernet Technical data

07. har-link Interface Connectors

Detailed Specifications & Technical Data

Product Information. ECN 1023 EQN 1035 Rotary Encoders with EnDat 2.2 for Safety-Related Applications

CENTERLINE 2100 Motor Control Center with IntelliCENTER Technology Using an EtherNet/IP Network

07. har-link INTERFACE CONNECTORS

Amphenol Overmolded Ethernet and USB solutions

Cat.6/5e UTP Patch Panels with 45 Jack

PROFINET Cabling and Interconnection Technology

PROFINET Cabling and Interconnection Technology

1/2 microfast Connectivity

Modular plugs, accessories and tooling

BULLETIN. Surveillance System Camera Technology

Transcription:

Table of Contents Guide...7-2...7-3 Unshielded Twisted Pair...7-5 Shielded Twisted Pair...7-6 600V Ethernet Cable...7-7 Cordsets & Patchcords RJ45...7-9 M12 Flex-Rated...7-10 M12 Receptacle Flex-Rated...7-12 Patchcords & Field Attachables Die-Cast Zinc RJ45 Connector, Variant 1...7-14 Thermoplastic RJ45 Connector, Variant 1...7-16 M12 Insulation Displacement Connectors...7-20 M12 to RJ45 Bulkhead Connector...7-22 Cat. No. Index...12-1 PannelConnect 7-1

Guide Ethernet General PannelConnect s Available Models 1585 Ethernet Cable Spools 2 and 4 pair, shielded and unshielded cable Unshielded - PVC riser, high-flex TPE, plenum PVC Shielded - PVC riser, high-flex, and halogenfree PUR, PVC 600V Field attachable RJ45, M12, Variant 1 connectors Cable spools for customized 1585J In-Cabinet RJ45 cordsets, patchcords, and field attachable connectors Available in 2 and 4 pair Shielded and unshielded cable types Rugged strain relief for secure connection RJ45 Pre-assembled patchcords IDC field attachable connectors for custom 1585D On-Machine 1585B On-Machine Variant 1 IP67 M12 D Code IP67 Variant 1 connectivity cordsets, patchcords, and - RJ45 connection with field attachable connectors protective housing Available in 2 pair High-flex cable Male/female, straight/right angle receptacle M12 D Code M12 D Code to RJ45 M12 D Code receptacle to RJ45 Pre-assembled patchcords IDC field attachable connectors for custom Available in diecast zinc and thermoplastic Overmolded patchcords Male and female Male plug Female outlet Female RJ45 to RJ45 coupler Variant 1 - RJ45 with housing for IP67 Pre-assembled patchcords IDC field attachable connectors for custom 1585 Ethernet Bulkhead Connector Sealed media based on 4- pin D-coded micro (M12) connections 4-pin D-coded M12 Threaded connection IP67 rating Rugged durable construction M12 RJ45 to D-coded micro IDC field attachable connectors M12 to RJ45 bulkhead pass-thru Additional Info See page 7-5 See page 7-9 See page 7-10 See page 7-14 See page 7-22 7-2

PannelConnect As ethernet becomes increasingly utilized in industrial control, survival of physical media in rugged or harsh environments is becoming a necessity. The high speed of network protocol allows it to be used in where other networks fall short. EtherNet/IP uses both standard ethernet and TCP/IP technologies and an open application layer protocol called the Control and Information Protocol (CIP). This is the same application layer used in and ControlNet networks. Rockwell Automation Cat5e ethernet cables are designed to supply a reliable network connection in harsh surroundings. By optimizing the balance of twisted pair conductors inside a robust Thermoplastic Elastomer (TPE) jacket, data is protected from noise, chemicals, and mechanical issues to M 3 I 3 C 3 E 3 environmental protection levels. The cable is available in RJ45 patchcords for IP20 or in four-pin D-coded M12 patchcords for IP67 where high vibration, fluids, and other contaminants can threaten the reliability of a network. M12 D-code field attachable insulation displacement connectors (IDCs) are available in both shielded and unshielded housings with male or female connectors. Male eight-pin RJ45 connectors are available in both a crimp termination and a toolless IDCs for custom cabling. Rockwell Automation M12 to RJ45 bulkhead connectors provide an elegant transition for network architecture from an IP20 setting to an IP67 environment. The adaptor can be used to connect remote junction boxes or implement an On- Machine solution with Armor I/O products. The Rockwell Automation ethernet media portfolio provides reliable connectivity to maintain network integrity and prevent costly downtime from troubleshooting. M12 patchcords can be used with the following sensing products: 48MS MultiSight vision sensors 54RF, 55RF, and 56RF RFID ethernet control interfaces 7-3

Ethernet Architecture Layout PannelConnect 1. RJ45 to RJ45 Patchcord...7-17 2. M12 to RJ45 Bulkhead Connector...7-22 3. M12 to M12 Patchcord...7-9 4. Stratix Ethernet Switch...9-1 5. ArmorBlock...10-1 6. ArmorPOINT Ethernet Module...10-13 7. Auxiliary Power Mini Receptacle...6-60 8. Auxiliary Power Mini Patchcord...6-55 9. Auxiliary Power Mini T-Port...6-61 10. DC Micro Patchcord...3-44 11. M23 Pigtail...3-132 12. DC Micro Distribution Box...4-14 13. PowerFlex Drive Switch with QD...See Drives catalog 14. MultiSight...See Sensors catalog 7-4

Unshielded Twisted Pair Unshielded Ethernet Cable Spool Rockwell Automation s Cat5e shielded and unshielded cable is designed to supply a reliable network connection in harsh surroundings. The high speed data rate allows more data to be transferred within a shorter period of time. By optimizing balance of twisted pair conductors inside a robust thermoplastic elastomer (TPE) jacket, data is protected from noise, chemicals, and mechanical issues to M 3 I 3 C 3 E 3 environmental protection levels. Two and four pair TPE robotic flex cable is available for flex reaching 10 million cycles, as well as a riser PVC cable for standard and a plenum PVC cable for air duct. All ethernet media components are designed to perform above TIA 568-B.2 and ODVA ethernet standards. Rockwell Automation's Bulletin 1585 ethernet cables are optimized UTP and STP cables in many. Specifications Certifications Conductor Material Bend Radius Data Rate Voltage Four- and eight-conductor styles Twisted pair unshielded cable types, Cat 5e Twisted pairs maintain signal balance through cable to provide high noise immunity and return loss Designed to ODVA EtherNet/IP specifications and ISO IEC 24702 Suitable for high noise environments M 3 I 3 C 3 E 3 Cable and Color Code Two-Pair UL Listed and CEC Tinned copper stranded 10 million cycles at 20 x diameter (TPE cable) Up to 1 Gb/s, Cat 5e 300V Riser PVC cables used for general purpose environments TPE robotic cable used for flex, transmission-tested to 10 million cycles Plenum PVC cable used for air duct TPE cable meets channel transmission performance to 10 million flexes Four-Pair Product Selection Jacket Material Robotic TPE Robotic TPE Plenum Cable Type Unshielded No. of Conductors Jacket Color Wire Size, AWG White/Orange White/Green Orange Green Nominal Outer Diameter White/Orange Orange White/Green Blue White/Blue Green White/Brown Brown Operating Temperature [C (F)] Cable Rating Cat. No. Weld splatter, 1585-C4TB-S100 4 (two pair) 5.6 mm (0.22 in.) -40 +75 Teal 24 8 (four pair) 5.84 mm (0.23 in.) ( 40 +167) sunlight, and oil 1585-C8TB-S100 resistant; UL CM, CMX; cul CM; Standard TIA 568-1585-C8VB-S100 B, high flex rated Unshielded 8 (four pair) Red 24 5.84 mm (0.23 in.) Riser PVC Unshielded 8 (four pair) Teal 24 5.84 mm (0.23 in.) -40 +75 (-40 +167) -40 +75 (-40 +167) UL CMP; cul CMP; Standard TIA 568-B UL CMR; cul CMG; Standard TIA 568-B Replace 100 (100 m) with 300 (300 m) or 600 (600 m) for additional standard cable lengths (example 1585-C4TB-S100 becomes 1585-C4TB-S600). 1585-C8MB-S100 1585-C8PB-S100 PannelConnect 7-5

Shielded Twisted Pair (Foil & Braided Shield) Shielded Ethernet Cable Spool Rockwell Automation s Cat5e shielded and unshielded cable is designed to supply a reliable network connection in harsh surroundings. The high speed data rate allows more data to be transferred within a shorter period of time. By optimizing balance of twisted pair conductors inside a robust thermoplastic elastomer (TPE) jacket, data is protected from noise, chemicals, and mechanical issues to M 3 I 3 C 3 E 3 environmental protection levels. Two and four pair polyurethane (PUR) robotic flex cable and enclosures are available for flex. High voltage, 600V Ethernet cable is available for use in cable tray with high voltage power cables. All ethernet media components are designed to perform above TIA 568-B.2 and ODVA ethernet standards. Rockwell Automation's Bulletin 1585 ethernet cables are optimized UTP and STP cables in many. Specifications Certifications Conductor Material Bend Radius Data Rate Voltage Four- and eight-conductor styles Twisted pair shielded cable types, Cat 5e Twisted pairs maintain signal balance through cable to provide high noise immunity and return loss Designed to ODVA EtherNet/IP specifications and ISO IEC 24702 Suitable for high noise environments M 3 I 3 C 3 E 3 Cable and Color Code Two-Pair White/Orange White/Green Orange Green UL Listed and CEC Tinned copper stranded 10 million cycles at 20 x diameter (TPE cable) Up to 1 Gb/s, Cat 5e 300V Riser PVC cables used for general purpose environments PUR robotic cable used for flex, also Halogen-free 600V PVC cable designed to support high voltage 600V On-Machine rated cable for use in a cable tray shared with high voltage power cables Four-Pair White/Orange Orange White/Green Blue White/Blue Green White/Brown Brown PannelConnect Product Selection Jacket Material Riser PVC Robotic PUR 600V PVC Cable Type Foil and braided shield No. of Conductors 8 (four pair) Jacket Color Wire Size, AWG Nominal Outer Diameter 5.84 mm (0.23 in.) 4 (two pair) Teal 26 8 (four pair) 8 (four pair) Teal Red 22 6.2 ± 12 mm (0.244 in.) 8.13 ± 0.38 mm (0.32 in.) 8.13 ± 0.38 mm (0.32 in.) Operating Temperature [C (F)] Cable Rating Cat. No. -40 +75 (-40 +167) -40 +75 (-40 +167) -40 +75 (-40 +167 ) -20 +80 (-4 +176 ) -20 +80 (-4 +176 ) UL CMR; cul CMG; TIA-568-B C(ETL)US TYPE CMX; TIA 568-B, Flex rated, Halogen-Free C(ETL)US TYPE CMX; TIA 568-B, Flex rated, Halogen-Free (UL) CMX, CMR; c(ul) CMG; (UL) PLTC or AWM 2570 80 C 600V; TIA-568-B (UL) CMX, CMR; c(ul) CMG; (UL) PLTC or AWM 2570 80 C 600V; TIA-568-B Replace 100 (100 m) with 300 (300 m) or 600 (600 m) for additional standard cable lengths (example 1585-C4TB-S100 becomes 1585-C4TB-S600). 1585-C8CB-S100 1585-C4UB-S100 1585-C8UB-S100 1585-C8HB-S100 1585-C8EB-S100 7-6

600V Ethernet Cable RJ45 Cordset 600V Rockwell Automation s Cat5e shielded and unshielded cable is designed to supply a reliable network connection in harsh surroundings. The high speed data rate allows more data to be transferred within a shorter period of time. By optimizing balance of twisted pair conductors inside a robust TPE jacket, data is protected from noise, chemicals, and mechanical issues to M 3 I 3 C 3 E 3 environmental protection levels. Two and four pair PUR robotic flex cable is available for flex, reaching 10 million cycles, as well as a riser PVC cable for standard. High voltage, 600V ethernet cable is available for use in a cable tray with high voltage power cables. All ethernet media components are designed to perform above TIA 568-B.2 and ODVA ethernet standards. Rockwell Automation's Bulletin 1585 ethernet cables are optimized UTP and STP cables in many. Foil and braided shield, PVC, eight conductor (four pair) 600V PVC cable designed to support high voltage On-Machine rated cable for use in a cable tray shared with high voltage power cables RJ45 insulation displacement connector available for field terminations Specifications Certifications Outside Diameter Operating Temperature Cable Rating Approximate Dimensions RJ45 IDC Connector View Shown with Cap 6.6 (0.26) 13.9 (0.55) View Shown without Cap 11.68 (0.46) RJ45 Cordset & Patchcord UL and cul Listed 0.32 ± 0.015 in. (8.13 ± 0.38 mm) -20 +80 C (-4 +176 F) UL, cul TYPE CMG; UL PLTC or UL AWM 2570 80C 600V, TIA 568B 53.1 (2.09) 51.2 (2.02) 12 87 29.3 (1.15) PannelConnect B PC 12 87 13.8 (0.054) 14.2 (0.56) 7-7

600V Ethernet Cable PannelConnect Pinout Color Code A Product Selection Jacket Material 600V PVC RJ45 Cordset Cable Type Foil and braided shield No. of Conductors 8 (four pair) Jacket Color Teal Red Wire Size, AWG 22 Nominal Outer Diameter 8.13 ± 0.38 mm (0.32 in.) Operating Temperature [C (F)] Cable Rating Cat. No. -20 +80 (-4 +176 ) (UL) CMX, CMR; c(ul) CMG; (UL) PLTC or AWM 2570 80 C 600V; TIA-568- B Replace 100 (100 m) with 300 (300 m) or 600 (600 m) for additional standard cable lengths (example 1585-C4TB-S100 becomes 1585-C4TB-S600). Shielding Cable Type Cat. No. Foil and braided shield 8 conductor, teal 600V PVC 1585J-M8HB-2 1585J-M8EB-2 RJ45 Patchcords 1585-C8HB-S100 1585-C8EB-S100 No. of Conductors Jacket Material Cable Type Cable Rating Cat. No. Teal 600V PVC (UL) CMX, CMR; c(ul) CMG; (UL) PLTC or 1585J-M8HBJM-2 8 Foil and braided shield Red 600V PVC AWM 2570 80 C 600V; TIA-568-B 1585J-M8EBJM-2 Replace -2 (2 m) with 5 (5 m) or 10 (10 m) for additional standard cable lengths. RJ45 IDC Connector 1 White/Orange 2 Orange 3 White/Green 4 Blue 5 White/Blue 6 Green 7 White/Brown 8 Brown Face View RJ45 Pinout 8-Pin 8 7 6 5 4 3 2 1 8-Pin TxData + TxData - Recv Data + Recv Data - Insulation Diameter [mm (in.)] Cable Diameter [mm (in.)] Cat. No. 0.85 1.6 (0.033 0.063) 5 9 (0.197 0.354) 1585J-M8CC-SH 7-8

Cordsets & Patchcords RJ45 Specifications Certifications UL Listed Connectors RJ45 Male to RJ45 Male, Cat 6 Cable Type Unshielded 4- and 8-conductor, 24 AWG, Industrial Cat5e Shielded 8-conductor 26 AWG Industrial Cat5e Enclosure Type Rating IP20 Nominal Outer Diameter 5.84 mm (0.23 in.) Operating Temperature [C (F)] -20 +60 (-4 +140 ) Voltage 300V Flex rated TPE, PVC, and Plenum cables for various Teal or red cable jacket Rugged strain relief and latch mechanism to maintain network integrity Suitable environments M 1 I 1 C 2 E 2 Product Selection Cordset Patchcords Shielding Cable Type Cat. No. Unshielded twisted pair Foil and braided shield Approximate Dimensions Dimensions are in millimeters (inches). Illustrations are not drawn to scale. Example of Cordset Pinout Example of Patchcord No. of Conductors Jacket Material Cable Type Cable Rating Cat. No. 4 Teal high-flex TPE 1585J-M4TBJM-2 Teal high-flex TPE Weld splatter, sun light and oil resistant; UL CMG, CMX; cul CMG; Standard TIA 568-B, flex rated 1585J-M8TBJM-2 8 Red high-flex TPE Unshielded twisted pair 1585J-M8VBJM-2 Teal Riser PVC UL CMR; cul CMG; Standard TIA 568-B 1585J-M8PBJM-2 Red Plenum UL CMP; cul CMP; Standard TIA 568 B 1585J-M8MBJM-2 4 Teal high-flex PUR 8 RJ45 Cordset 4 conductor, teal high-flex TPE 1585J-M4TB-2 8 conductor, teal high-flex TPE 1585J-M8TB-2 8 conductor, red high-flex TPE 1585J-M8VB-2 8 conductor, teal riser PVC 1585J-M8PB-2 8 conductor, red plenum PVC 1585J-M8MB-2 8 conductor, teal riser PVC 1585J-M8CB-2 4 conductor, teal high-flex PUR 1585J-M4UB-2 8 conductor, teal high-flex PUR 1585J-M8UB-2 8 conductor, teal 600V PVC 1585J-M8HB-2 8 conductor, red 600V PVC 1585J-M8EB-2 Foil and braided shield C(ETL)US TYPE CMX; TIA 568-B, flex-rated, halogen-free 1585J-M4UBJM-2 Teal Riser, PVC UL CMR; CUR CMG, TIA B 1585J-M8CBJM-2 Teal high-flex PUR Teal 600V PVC Red 600V PVC Replace -2 (2 m) with 5 (5 m) or 10 (10 m) for additional standard cable lengths. Color Code A 8-Pin 1 White/Orange 2 Orange 3 White/Green 4 Blue 5 White/Blue 6 Green 7 White/Brown 8 Brown Face View RJ45 Pinout 8-Pin 8 7 6 5 4 3 2 1 TxData + TxData - Recv Data + Recv Data - C(ETL)US TYPE CMX; TIA 568-B, flex-rated, halogen-free (UL) CMX, CMR; c(ul) CMG; (UL) PLTC or AWM 2570 80 C 600V; TIA-568-B Accessories RJ45 insulation displacement connector (IDC) RJ45 crimp connector with boot 4-Pin 1 White/Orange 2 Orange 3 White/Green 4 NA 5 NA 6 Green 7 NA 8 NA One item includes a quantity of 50. TxData + TxData - Recv Data + Recv Data - 1585J-M8UBJM-2 1585J-M8HBJM-2 1585J-M8EBJM-2 Cat. No. 1585J-M8CC-H 1585J-M8CC-C PannelConnect 7-9