PAN11-1B Smart energy plug in switch

Similar documents
PAN11. Smart energy plug in switch

PAN03 ; PAN10 Switch Module with meter

PAD02. Z-Wave Smart Dimmer Socket. Adding to Z- Wave TM Network

PAN04 In Wall Dual relay(1 way) switch module. Adding to Z-Wave TM Network

TWO SPDT Switch module with meter

Adding to Z-Wave TM Network

Adding to Z-Wave TM Network 1

Adding to Z-Wave TM Network

SA-102. Smart In Wall Dual Switch. User Manual

Adding to Z-Wave TM Network

DCH-122 PIR Motion Sensor

PACKAGE CONTENTS SPECIFICATIONS

SI-103. Flood Sensor. User Manual

PRODUCT DIAGRAM PACKAGE CONTENTS

SI-102. PIR Motion Sensor. User Manual

SI in 1 Multi-sensor. User Manual

PACKAGE CONTENTS SPECIFICATIONS PRODUCT DIAGRAM

HomePro ZDP100. Radio Frequency Controlled, 300W, 120 VAC, Plug-In Lamp Module, Release 2.0 ZDP100 PLUG-IN LAMP MODULE INSTALLATION

POP_ Z-Wave Schuko Plug-in Switch plus Power Meter Firmware Version : 1.1

PRODUCT DIAGRAM PACKAGE CONTENTS

TZ75 Roller shutter controller

Instruction Manual Power plug Model number: STW-W3350WU

Quick start Energy Switch EU

BTK-A21 Bluetooth Headset User Manual

OPERATING MANUAL. NanoMote Quad ZWA003-A/C

Micro Dimmer MH-P220. *Note: For non-resistive load, a derating output is highly suggested.

Aeon Labs Nano Switch

5/8 Port Gigabit Ethernet Switch

HomePro ZRW113. Radio Frequency Controlled, 120 VAC, Isolated Contact Wall Mounted 3-Way Switch ZRW113 WALL MOUNTED SWITCH INSTALLATION

Chicony Standard Bluetooth Keyboard Users Manual. Model No.: KT-1063

ZigBee TM - Measurement and Switch Socket. User Manual. Measurement and Switch Socket Model: Z809A. Firmware: V3.5 Hardware: V1.2

IAD18000/18001 Hardware User Manual

Aeon Labs Dual Nano Switch

TV WIRELESS HEADPHONES

Bluetooth Mini Keyboard. User s Manual. Version /05 ID NO: PAKL-231B

AXIS T8341 PIR Motion Sensor. User Manual

Wireless Lighting Control ZRM-M80 Z-Wave Smart Plug (with switch and energy meter) USER MANUAL

Wireless Lighting Control. On/Off/Dim. Lamp Module. Z-Wave Certified Wireless Lighting Control

ÿ ÿ HA09 - HANDY REMOTE CONTROLLER INSTRUCTIONS

IRONKEY H80 USER GUIDE

Wireless Lighting Control. On/Off. Outdoor Module.

BiPAC 2073 R2. BiPAC 2074 R2

USER GUIDE. Element Wireless Smart Plug Model: E1C-NB6

Aeon Labs Nano Dimmer

Wall Controller WALLC

REMOTE CONTROL USER MANUAL QUICK CONNECT MINI-SPLIT

Bluetooth Hands-Free Speaker Phone Custom Accessories 23685

Alcatel - Lucent 8115 Audioffice

SafeNet Reader CT1100. For Windows 7, 8.1 and 10 User Guide

Touch Panel Dimmer MH-P511. Introduction

8 Port Gigabit Ethernet Switch User Manual (P/N: 41NE-G3800UD0-A00)

Supertooth One Users manual

BBW200 SmartClim Bluetooth Smart Temperature and Humidity Sensor User Manual

Chant. Portable Bluetooth Audio System

utv 2 description The Unitron utv 2 connects your A2DP Headset wirelessly to your TV or other audio devices. utv 2 (f) (g)

EXO-110 Bluetooth Headband

F O R E S T S H U T T L E S / L Z - W

User Manual. Daffodil. 2.4GHz Wireless Mouse Souris Sans Fil 2.4GHz 2.4GHz Wireless Maus Mouse senza fili da 2.4 GHz Ratón Inalámbrica 2.

Z-WavePlus Siren Installation Instructions

To force your device to restart, press and hold the power button until your device vibrates.

Network Camera. Quick Guide DC-B1203X. Powered by

2. Press Fn switch 3 times in a row again to exclude the device from Z-Wave network.

Hardware Installation 1. Install two AA batteries in the mouse. Pairing Process in Vista and Windows XP SP2

Prime bolt User Manual

Operation Manual for Cloud 3700F Version 0

Wireless Bluetooth Music Receiver

N331 Wireless Mini Optical Mouse User s Guide

USER GUIDE. Smart Wi-Fi LED Bulb (2700K and 5000K) Model: W11-N11

Deluxe In/Out Remote Thermometer with Trend Chart

HONGKONG UCLOUDLINK NETWORK TECHNOLOGY LIMITED. 4G Free Roaming Hotspot

PTT-100-VZ Wireless Speaker Microphone

WALL MOUNTED SWITCH MANUAL

User Guide for Yeelight Bedside Lamp

Charging Pad / Charging Stand

ADVANCED REMOTE CONTROL

Wireless Outlet User Manual

1. Product Description. 2. Product Overview

IEEE g Wireless PC Card. User s Guide

Z-Wave 4-in-1 Multi Sensor HZS-300E/HZS-300A

Digital Photo Album Operation Manual

INSTRUCTIONS. A0325 ARIA Audio Streaming Source Receiver with built-in Bluetooth 4.2 Module MADE IN THE USA 2017 CHANNEL VISION TECHNOLOGY

XT-SW21-4K18G. Introduction. User Manual. Key Features XT-SW21-4K18G USER MANUAL

Battery Powered Motorized Window Shadings. Remote Control. Guide

Bi Directional Wireless IR Repeater System User Guide

Wireless Optical Mouse Instruction Manual

Contents Attentions... 2 Preparation... 4 Technical Specification... 7

Z-Wave Plus Smart Switch Dual Rocker. Installation Guide Ecolink Intelligent Technology Inc. PN DDLS2-ZWAVE5. A Universal Electronics Company

ATP1000 Touchpad/Display Installation Instructions

Wireless Palm Style Keyboard with Touchpad PKA-1720A. User s Manual. Version /08 ID NO:

INSTALLATION INSTRUCTIONS

SafeNet Reader K1100. For Windows 7, 8.1 and 10 User Guide

WIRELESS THIN-PROFILE KEYBOARD AND MOUSE USER S MANUAL.

NA502S Multiple RF Home Gateway

WavePRO Wireless Programmable T2500 Thermostat & R2500 Receiver OPERATING MANUAL. Model K

Aeon Labs Dual Nano Switch

Blackwire C610 Blackwire C620

Z-Wave Ceiling-mount Smoke Detector HZS-200E/HZS-200A

REMOTE CONTROL INSTALLATION & OPERATING INSTRUCTIONS

BLUETOOTH RECEIVER (RX) FOR IPOD DOCKING SPEAKER

SleepMinder TM Non Contact Sleep Monitoring

Transcription:

PAN11-1B Smart energy plug in switch The function of auto inclusion will be executed as long as the switch does not have Node ID and just plug the switch into a wall outlet. Note: Auto inclusion timeout is 2 minute during which the node information of explorer frame will be emitted once several seconds. Unlike inclusion function as shown in the table below, the execution of auto inclusion is free from pressing the On/Off button on the Switch. The table below lists an operation summary of basic Z-Wave functions. Please refer to the instructions for your Z-Wave TM Certificated Primary Controller to access the Setup function, and to include/exclude/associate devices P This plug-in ON/OFF switch PAN11 is a security enabled wireless switch, based on Z-Wave Plus technology. Z-Wave Plus TM enabled devices displaying the Z-Wave Plus TM logo can also be used with it regardless of the manufacturer, and can also be used in other manufacturer s Z-Wave TM enabled networks. Remote On/Off control of the connected load is possible with other manufacturer s wireless Controller. Each switch is designed to act as a repeater. Repeaters will re-transmit the RF signal to ensure that the signal is received by its intended destination by routing the signal around obstacles and radio dead spots. Because PAN11 supports Security Command Class, it can learn with Secured controller. Its functionality and supported command classes is identical when included as a secure and non-secure device. This plug-in ON/OFF switch is able to detect instance wattage (3000W/CE/CN, 1500W/UL/TW/JP) and overload current (14.5A) of connected lights or appliances. When detecting overload state, the Switch will be disabled and its On/Off button will be lockout of which LED will flash quickly. However, unplug and re-connect the switch will reset its overload condition to normal status. Adding to Z-Wave TM Network In the front casing, there is an On/Off button with LED indicator which is used to toggle switch on and off or carry out inclusion, exclusion, reset or association. When first power is applied, its LED flashes on and off alternately and repeatedly at 0.5 second intervals. It implies that it has not been assigned a node ID and start auto inclusion. Function Description Annotation No node ID The Z-Wave Controller does not allocate a node ID to the Switch. LED 2-second on, 2-second off Inclusion 1. Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer. 2. Pressing On/Off button three times within 2 seconds will enter inclusion mode. Exclusion 1. Put your Z-Wave controller into exclusion mode by following the instructions provided by the controller manufacturer. 2. Pressing On/Off button three times within 2 seconds will enter exclusion mode. Node ID has been excluded. Reset 1. Pressing On/Off button three times within 2 seconds will enter inclusion mode. 2. Within 1 second, press On/Off button again for 5 seconds. LED 0.5s On, 0.5s Off (Enter auto inclusion) Use this procedure only in the event that the primary controller is lost or otherwise inoperable. 3. IDs are excluded. LED 0.5s On, 0.5s Off (Enter auto inclusion) Auto Inclusion 1

Association 1. The PAN11 is an always listening Z-Wave device, so associations may be added or removed by a controller at any time. Or If your controller requires to have the PAN11 send a 'node information frame' or NIF for associations, then pressing the On/Off button three times within 2 seconds will cause the PAN11 to send its NIF. 2. There are only one group for the switch Including a node ID allocated by Z-Wave Controller means inclusion. Excluding a node ID allocated by Z-Wave Controller means exclusion. Failed or success in including/excluding the node ID can be viewed from the Z-Wave Controller. 4. After putting it into use, the body of Switch will become a little bit hot of which phenomenon is normal. Installation 1. Plug this On/Off Switch into a wall outlet near the load to be controlled. 2. Plug the load into the Switch. Make sure the load to be controlled cannot exceed 13A. 3. Press the button or switch on the load to the ON position. 4. To manually turn ON the Switch, press and release the On/Off button. The LED will turn ON, and the load plugged into the Switch will also turn ON. 5. To manually turn OFF the Switch, simply press and release the On/Off button. The LED will turn OFF and the load plugged into the Switch will also turn OFF. LED Indication To distinguish what mode the switch is in, view from the LED for identification. State Type Normal No node ID Learning Overload LED Indication Under normal operation, toggle On/Off button between On and Off. When pressing On, LED lights up, whereas Off, LED is off. Under normal operation, when the Switch has not been allocated a node ID, the LED flashes on and off alternately at 2-second intervals. By pressing On/Off button, it will stop flashing temporarily. When PAN11 is in learning mode, LED flashes on and off alternately and repeatedly at 0.5 second intervals. When overload state occurs, the Switch is disabled of which LED flashes on and off alternately at 0.2 second intervals. Overload state can be cleared by unplugging and reconnecting the Switch to the wall outlet. Choosing a Suitable Location 1. Do not locate the Switch facing direct sunlight, humid or dusty place. 2. The suitable ambient temperature for the Switch is 0 C~40 C. 3. Do not locate the Switch where exists combustible substances or any source of heat, e.g. fires, radiators, boiler etc. 2 Programming 1. Basic Command Class / Binary Switch Command Class The Switch will respond to BASIC and BINARY commands that are part of the Z-Wave system. 1-1 BASIC_GET / BINARY_SWITCH_GET Upon receipt of the following commands from a Z-Wave Controller, the Switch will report its On/Off state to the node asked. Basic Get Command: [Command Class Basic, Basic Get] Basic Report Command: Report OFF: [Command Class Basic, Basic Report, Value = 0(0x00)] Report ON:[Command Class Basic, Basic Report, Value = 255(0xFF)] Binary Switch Get Command:[Command Class Switch Binary, Switch Binary Get] Binary Switch Report Command: Report OFF:[Command Class Switch Binary, Switch Binary Report, Value =0(0x00)] Report ON:[Command Class Switch Binary, Switch Binary Report, Value = 255(0xFF)]

1-2 BASIC_SET / SWITCH_BINARY_SET Upon receipt of the following commands from a Z-Wave Controller, the load attached to the Switch will turn on or off. [Command Class Basic, Basic Set, Value = 1~99,255(0xFF)]: the load attached to the Switch turns on. [Command Class Basic, Basic Set, Value = 0(0x00)]: the load attached to the Switch turns off. [Command Class Switch Binary, Switch Binary Set, Value = 1~99, (255)0xFF]: the load attached to the Switch turns on. [Command Class Switch Binary, Switch Binary Set, Value = 0(0x00)]: the load attached to the Switch turns off. 2. Z-Wave s Groups (Association Command Class Version 2) The Switch can be set to send reports to associated Z-Wave devices. It supports one association group with one node support for Grouping 1. For group 1, the Switch will report its latest status to Z-Wave Controller. Grouping 1 includes, SWITCH_BINARY_REPORT, METER_REPORT, ALARM_REPORT. 2-1 Auto report to Grouping 1 (Maximum Node 1) 2-1-1 On/Off Event Report When on or off state has been changed, it will send Binary Switch Report to the node of Grouping 1. Binary Switch Report ON:[Command Class Switch Binary, Switch Binary Report, Value =255(0xFF)] OFF:[Command Class Switch Binary, Switch Binary Report, Value =0(0x00)] 2-1-2 Instant Power Consumption vary over 5% report When the power consumption of load vary over 5%, it will send Meter report to the nodes of Grouping 1. 0x01,Precision = 1,Scale = 0x02,Size = 4,Meter Value(W) ] 2-1-3 Overload alarm report When PAN11 detects the current is more than 14.5A, it will send Alarm Report to Group 1 The content of Alarm Report Alarm report command: [Command_Class_Alarm, Alarm_Report, Alarm Type = 0x08, Alarm Level = 0xFF] 2-2 Response to Meter Get Command The Switch will report its (1) instant Power Consumption (Watt) or (2) accumulated power consumption(kwh) or (3) AC load Voltage (V) or (4) AC load current ( I ) (5) load power factor (PF) to Z-Wave Controller after receive the Meter Get Command from Z-Wave Controller. 2-2-1 Instant Power Consumption (Watt) of Switch Meter Get Command: [Command Class Meter, Meter Get, Scale =0x02(W)] 0x01,Precision = 1,Scale = 0x02,Size = 4,Meter Value(W) ] Meter Value 1 = 0x00 (W) Meter Value 2 = 0x00 (W) Meter Value 3 = 0x03 (W) Meter Value 4 = 0xEA (W) Meter(W) = Meter Value 3 *256 + Meter Value 4 = 100.2W 3

2-2-2 Accumulated Power Consumption (KW/h) When receiving Meter Get Command, it will report Meter Report Command to the Meter Get Command: [Command Class Meter, Meter Get, Scale = 0x00 KW/h)] [Command Class Meter,Meter Report,Rate Type = 0x01, Meter Type = 0x01, Precision = 2,Scale = 0x00,Size = 4,Meter Value (KWh)] Scale = 0x00 (KWh) Precision = 2 Size = 4 Bytes (KW/h) Meter Value 1 = 0x00(KWh) Meter Value 2 = 0x01(KWh) Meter Value 3 = 0x38(KWh) Meter Value 4 = 0xA3(KWh) Accumulated power consumption (KW/h) = (Meter Value 2*65536) + (Meter Value 3*256) + (Meter Value 4) = 800.35 (KW/h) 2-2-3 Clearing accumulated power consumption Whenever re-start counting the accumulated power consumption is needed, you can use Meter Reset Command to clear it. Meter Reset Command: [Command Class Meter, Meter Reset] 2-2-4 AC load Voltage (V) Meter Get Command: [Command Class Meter, Meter Get, Scale =0x04(V)] 0x01,Precision = 1,Scale = 0x04,Size = 2, Meter Value(V)] Scale = 0x04 (V) Precision = 1 Size = 2 (2 Bytes of V) Meter Value 1 = 0x09(V) Meter Value 2 = 0x01(V) AC load Voltage = (Meter Value 1*256) +(Meter Value 2)= 230.5 (V) 2-2-5 AC load current ( I ) Meter Get Command: [Command Class Meter, Meter Get, Scale =0x05(I)] 0x01, Precision = 2,Scale = 0x05,Size = 2,Meter Value(I)] Scale = 0x05 (I) Precision = 2 Size = 2 (2 Bytes of I) Meter Value 1 = 0x01(I) Meter Value 2 = 0x21(I) AC load current = (Meter Value 1*256) +(Meter Value 2)= 2.89 (A) 2-2-6 load power factor (PF) Meter Get Command: [Command Class Meter, Meter Get, Scale =0x06(PF)] 4

0x01, Precision = 2,Scale = 0x06,Size = 1 Bytes,Meter Value(PF)] Scale = 0x06 (PF) Precision = 2 Size = 1 (1 Byte of PF) Meter Value 1 = 0x63(PF) (It means that the load power factor is 0.99) 3-1 Watt Meter Report Period: If the setting is configured for 1hour (set value =720), the PAN11 will report its instant power consumption every 1 hour to Group1 The maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr). 3-2 KWH Meter Report Period: If the setting is configured for 1hour (set value =6), the PAN11 will report its Accumulated Power Consumption (KW/h) every 1 hour to Group1 The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55 days). 3. Z-Wave s Configuration Configuration Parameter Function 1 Watt Meter Report Period 2 KWH Meter 3 4 5 6 7 8 9 Report Period Threshold of current for Load caution Threshold of KWh for Load caution Restore switch state mode Mode of Switch Off function LED indication mode Auto off timer RF off command mode Size (Byte) Value Unit Default Description 2 0x01-5s 720 720*5s=3600s=1 hour 0x7FFF 2 0x01-10min 6 6*10min=1 hour 0x7FFF 2 10-1300 0.01A 1300 1300*0.01A = 13A 2 1-10000 1KWh 10000 1 0-2 1 0 : Switch off 1 : Last switch state 2 : Switch on 1 0-1 1 0 : Disable 1 : Enable 1 1-3 1 1 : Show switch state 2 : Show night mode 3 : One flash mode 2 0-0x7FFF 1s 0 0 : Disable auto off function 1-0x7FFF : 1s ~ 32767s 1 0-3 0 0 : Switch off 1 : Ignore 2 : Switch toggle 3 : Switch on 5 3-3 Threshold of current for Load Caution This is a warning when the current of load over the preset threshold value, if the setting value is 1300, when the load current of Relay1 over this value, PAN11 will send current meter report to warn the Group1 node, the Range of the setting value is from 10 to 1300,and the default value is 1300. 3-4 Threshold of KWh for Load Caution This is a warning when the KWh of load over the preset threshold value, If the setting value is 10000, when the Accumulated Power Consumption of Relay1 over this value, PAN11 will send KWH meter report to warn the Group1 node, minimum value is 1KWh and default value is 10000 kwh. 3-5 Restore switch state mode : Whenever the AC power return from lost, PAN11 will restore the switch state which could be SWITCH OFF LAST SWITCH STATE SWITCH ON. The default setting is LAST SWITCH STATE. 3-6 Mode of switch off function : When the mode of switch On/Off is set to 0, any command of switch off will be disabled and the On/Off function of include button will be disabled. The default setting is enable mode. 3-7 LED indication mode : 3-7-1 Show Switch State:When switch is on, LED is on. When switch is off, LED is off. The default setting is Show Switch State. 3-7-2 Show Night mode:when switch is on, LED is off. When switch is off, LED is on. 3-7-3 One Flash mode:when the state of switch changes, LED will be on only one second, then LED keeps off. 3-8 Auto off timer: Whenever PAN11 switches to on, the auto off timer begin to count down. After the timer decrease to zero, it will switch to off automatically. However if Auto off timer

is set as 0, the auto off function will be disabled. The default setting is 0. 3-9 RF off command mode Whenever a switch off command, BASIC_SET BINARY_SWITCH_SET SWITCH_ALL_OFF, is received, it could be interpreted as 4 variety of commands. 3-9-1 Switch Off:It switches to OFF state. The default setting is Switch Off. 3-9-2 Ignore:The switch off command will be ignored. 3-9-3 Switch Toggle:It switches to the inverse of current state. 3-9-4 Switch On:It switches to ON state. 4. Protection Command Classes PAN11 supports Protection Command Class version 2, it can protect the switch against unintentionally control by e.g. a child. And it can also protect the switch from being turned off by setting it in No RF Control state. After being set to Protection by sequence state, any intentional pressing of On/Off button should be hold longer than 1 second, or the switch state will not change. However, the operation of learn function does not change, because learning will not be protected. 5. Firmware update over the air (OTA) PAN11 is based on 500 series SoC and supports Firmware Update Command Class, it can receives the updated firmware image sent by controller via the Z-wave RF media. It is a helpful and convenient way to improve some function if needed. 6. Command Classes The Switch supports Command Classes including * COMMAND_CLASS_ZWAVEPLUS_INFO * COMMAND_CLASS_VERSION * COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 * COMMAND_CLASS_SECURITY * COMMAND_CLASS_DEVICE_RESET_LOCALLY * COMMAND_CLASS_ASSOCIATION_V2 * COMMAND_CLASS_ASSOCIATION_GRP_INFO * COMMAND_CLASS_POWERLEVEL * COMMAND_CLASS_SWITCH_BINARY * COMMAND_CLASS_BASIC * COMMAND_CLASS_SWITCH_ALL * COMMAND_CLASS_METER_V3 * COMMAND_CLASS_CONFIGURATION * COMMAND_CLASS_ALARM * COMMAND_CLASS_PROTECTION * COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 Note: Please make sure that the intensity of the plug of the electrical device must be 16A and have same head as the enclosed plug before inserting to the socket. Troubleshooting Symptom Cause of Failure Recommendation The Switch not working and LED off The Switch LED illuminating, but cannot control the ON/OFF Switch of the load attached The Switch LED illuminating, but the Detector cannot control the Switch LED keep flashing, but cannot control Specification 1. The Switch is not plugged into the electrical outlet properly 2. The Switch break down 1.Check if the load plugged into the Switch has its own ON/OFF switch 2. The switch is protected 1. Not carry out association 2. Same frequency interference Overload occurs 1. Check power connections 2. Don t open up the Switch and send it for repair. 1. Set the ON/OFF switch of the load attached to ON 2. Unprotected the switch or follow the instruction of protection. 1. Carry out association 2. Wait for a while to re-try Remove the load attached or check max. load cannot exceed 13.0A Operating Voltage 230V/50Hz Maximum Load 13A Range Minimum 30 m in door 70m outdoor line of sight Operating Temperature 0 C ~ 40 C Frequency Range 868.40MHz & 869.85MHz/EU/CN(PAN11-1B/-2B/-3B/-8B), 908.40MHz & 916.00MHz/UL(PAN11-4B), 922~927MHz/TW/JP(PAN11-5B) ** Specifications are subject to change and improvement without notice. 6

FCC ID : RHHPAN11 used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct Warning: 1.Plug out to disconnect from power supply; Do not plug in line. 2. Do not exceed the max rating the interference by one of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is Disposal This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling. connected. Consult the dealer or an experienced radio/tv technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause Company of License Holder:Philio Technology Corporation Address of License Holder:8F.,No.653-2,Zhongzheng Rd., Xinzhuang Dist., New Taipei City 24257,Taiwan(R.O.C) undesired operation. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. FCC Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and 7