FieldServer X-25 Start-Up Guide

Similar documents
FieldServer X-20 Start-Up Guide

FieldServer EZ Gateway Modbus to BACnet Start-up Guide FS-EZX-MOD-BAC

Hubbell Building Automation #LXBASM. ProtoNode LER Startup Guide

BACnet Router Start-up Guide

BACnet Router Start-up Guide

Doc October ProtoNode Reference Manual

FieldServer BACnet Router Wi-Fi FS-ROUTER-BACW Start-up Guide BAS Router (BACnet Multi-Network Router)

FieldServer BACnet Router Wi-Fi FS-ROUTER-BACW Start-up Guide BAS Router (BACnet Multi-Network Router)

FieldServer BACnet Router FS-ROUTER-BACX Start-up Guide BAS Router (BACnet Multi-Network Router)

FieldServer EZ Gateway M-Bus to Modbus & BACnet Start-up Guide FS-EZX-MBUS-MOD-BAC

62532 (EN649) Ethernet Adapter

62533 Ethernet Adapter

CTI 3570A SERIES INDUSTRIAL ETHERNET SWITCH INSTALLATION AND OPERATION GUIDE Version 1.2

ilink Installation & User Manual Internet Downloadable MP3 Music & Message Series

ProtoAir FPA-W34 Start-up Guide For Interfacing the Siemens MAG6000 To Building Automation Systems: BACnet/IP, Modbus TCP/IP and EtherNet/IP

EMC-1 TM. Ethernet Meterbus Converter. DIMENSIONS [inches (millimeters)] Installation and Operation Manual

USB Server User Manual

EZ Bridge B 100mW Product Guide

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

Installation Guide 24-port 10/100 Fast Ethernet Switch with 1 Fiber Connection Model Name: KS-324F

factory field upgrade

Plus-X 600. Installation and Operation Manual

Click! 301. Serial to Ethernet Converter

Plus-X 300. Installation and Operation Manual

XC300 VDSL Network Extender Owners Manual

MESR Port Industrial Modbus Gateway. Specifications Power. MESR424_r000_2913ds

VIP-480AL IP One-Way Horn

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

User Manual A08. User Manual

DGH A3000 Configuration Guide For use with DGH Modules

Industrial Ethernet Ethernet to Serial Gateways Ethernet to Serial Converters for Modbus, Red lion and other protocols

EIDX_M Series INSTALLATION GUIDE INTRODUCTION. A Line of Managed Ethernet Switching Hubs

Messager USB w/ Night Answer

Sonorous v2.0. Installation & User Manual

ELETICS Quickstart Installation Manual

Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual

ADAM Fiber Optic to RS-232/422/485 Converter

EDG Port Industrial 10/100 Mbps Ethernet Switch. User Manual

Sauter Systems

Bluetooth to Serial Converter TOP FRONT. Click 421

VIP-812A DUAL NETWORKED STATION PORT

USB Ranger Fiber Optic USB 2.0 Extender. User Guide

VP Process Inc. Model: VP-EC-RDU Modbus RTU LCD Display

USB Ranger 110/410 User Guide

1. Introduction... 1 Features... 1 Package Contents... 1 System Requirements... 1 LED Status... 2

General Operating, Maintenance and Installation Manual

Product names mentioned in this manual may be trademarks or registered trademarks of those products.

SECURE/NONSECURE LED SIGN USER MANUAL

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Online Connection Kit. Installation Manual

Guide Specification for 3G Wireless Battery Monitoring System

USB Ranger 422 User Guide

EZ Bridge G Product Guide

VE8014A/VE8014AR QUAD NETWORKED STATION PORT

MEC-LAN-M002. User s Manual

General Notice Introduction Functional Description Product Troubleshooting Driver Setup...

10/100Base-TX Industrial Ethernet Extender

Kramer Electronics, Ltd. USER MANUAL. Model: FC-1ETHN. Ethernet Controller

Plus-X RP-8 Adapter. Installation and Operation Manual

MCN Monitoring and Control Network Comparator Display System. Host Computer Interface Module HIB Hardware Reference Manual

ilink LCD/iLink LCD Wireless Installation & User Manual

Managed 100 Mbps Ethernet Switches TOP FRONT. Click 340/341/342

Woolich Racing. USB ECU Interface User Guide

305FX-N. Phone: Fax: Web:

Megabit Modem MM300S INSTALLATION GUIDE

Crestron CEN-SW-POE-5 5-Port Power over Ethernet Switch Installation Guide

Installation and Operation Manual. Ethernet Interface for SIMREX Radio Modems. SIMREX P/N: MAN.UBRIDGE Rev. B APRIL 2005

VIP-148AL IP Talkback Horn

CM17215HR 100Mb/s Fiber CM17212HR 10/100Mb/s UTP PC/104-Plus Dual Ethernet utilitymodule. User s Manual

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

5 Port Industrial Ethernet Switch. IES5100 Instruction Manual

Serial/Ethernet Converter

VIP-804 QUAD ENHANCED NETWORK AUDIO PORT

CM17320HR User's Manual Octal RS-232/422/485 PC/104-Plus Module

Model 282 Total Interface Isolation Module Reference Manual Rev. A Print Table of Contents 1.0 General Description 2.

-C5RS-LC RS232 EXTENDER

IntesisBox Modbus Server - Honeywell XLS 80

Messager USB by Nel-Tech Labs, Inc. Installation & User Manual

SERIES 4600 Ethernet Visual-Pager Display INSTALLATION and SPECIFICATION GUIDE. Manual No. D Revision Date: 08/2016 Control: 1.

TC1880 Series. 4/5/6/8 Channel RS-232 FIBER OPTIC MICRO MUX User's Manual

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

User Manual EKI-6528TI/ 6528TPI. EN port M12 Unmanaged/ PoE Switch with Wide Temperature

304TX-N. Phone: Fax: Web:

USB Ranger User Guide. Cat 5 USB 2.0 Extender with Remote Power. Powered by

LBC-PSW52. Link Bridge TM Presentation Scaling Switch with 5 Inputs and Two Mirrored Outputs

OL-KT. Online Connection Kit Installation Manual

CiM-25. Quick Start Guide. IP-Enabled M&C Part Number CD/CIM25QSG.IOM Rev. 0

Piccola Smart Box Member of Modul MAS family

Installation and User Guide

Plus-X Dual IP-8 Adapter. Installation and Operation Manual

CM17215HR 100Mb/s Fiber CM17212HR 10/100Mb/s UTP PC/104-Plus Dual Ethernet utilitymodule. User s Manual. BDM Rev. C

Introduction... 3 Gigabit Ethernet Technology... 4 Switching Technology... 4 Features Package Contents... 6

5/8-Port Industrial Fast Ethernet Switch ISW-500/ISW-800. User's Manual

InterChangeVS 1000 Series VS1000 and VS1100 Hardware

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

modunet292: novanet-ethernet interface

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

TRENDnet User s Guide. Cover Page

MEC-COM-M114. User s Manual

Transcription:

Sierra Monitor Company FieldServer X-25 Start-Up Guide APPLICABILITY & EFFECTIVITY Effective for all systems manufactured after April 2013 Kernel Version: 6.10 Document Revision: 0

FieldServer FS-X25 Start-Up Guide Table of Contents TABLE OF CONTENTS 1 Equipment Set-Up... 3 1.1 Supplied equipment... 3 1.2 Mounting... 3 1.3 Wiring... 3 1.3.1 Compliance with UL Regulations... 3 1.4 Specifications... 4 2 Product Description... 5 2.1 Features... 5 2.2 LED Indicators... 5 3 Connection to the Device... 6 3.1 Serial Connection... 6 3.1.1 DB-9 Pinouts for RS-232 Connection... 6 3.1.2 DB-9 Pinouts for RS-485 Connection... 7 3.2 Ethernet Connection... 7 4 Operation... 8 4.1 Record Identification Data... 8 4.2 Power up the device... 8 4.3 Install and Run the Utility Software... 8 4.4 Connect the PC to the FieldServer over the Ethernet port.... 8 4.5 Identification of the FieldServer on the Network... 8 4.6 Connection to the FieldServer Using RUI (Ruinet)... 9 4.7 Upload the Default Configuration... 9 4.8 Change the Configuration File to Meet the Application... 9 4.9 Download the updated Configuration file... 9 4.10 Test and Commission the FieldServer... 10 Appendix A. Troubleshooting Tips... 11 Appendix A.1. Connection to the FieldServer... 11 Appendix A.2. Technical support... 11 Appendix A.3. Material Service Orders (MSO) Procedure... 11 Appendix B. Limited Warranty... 12

FieldServer FS-X25 Start-Up Guide Page 3 of 12 1 EQUIPMENT SET-UP 1.1 Supplied equipment FS-X25 Series FieldServer. loaded with Modbus RTU driver, SMT Ethernet driver and any other drivers ordered. A default configuration file has already been loaded onto the FieldServer. Check the Driver Manual and the FieldServer Configuration Manual for further information on this file. USB Flash Drive loaded with: Accessories: FS-X25 Series Start-up Guide FieldServer Configuration Manual FieldServer Utilities Manual All FieldServer Driver Manuals Support Utilities Any additional folders related to special files configured for a specific FieldServer Additional components as required - See Driver Manual Supplement for details 7-ft Cat5 cable with RJ45 connectors at both ends (Part # FS-8915-10) Power Supply (Part # 69196) Power Cord (Part # 53029) DB9F/RJ45 Connection Adapter. (Part # FS-8917-02) Self-Adhesive feet (Part # 69178) 1.2 Mounting The FS-X25 Series FieldServer is supplied with an accessory bag which allows selection of adhesive feet (for standing on a shelf) or mounting plates for wall or panel mount. A DIN Rail Mounting Kit (P/N FS-8915-28) may be ordered separately. Din Rail Clip 2 required. 1.3 Wiring 5-30VDC must be connected to the terminal block 1.3.1 Compliance with UL Regulations For UL compliance, the following instructions must be met when operating the FieldServer. The units shall be powered by listed LPS or Class 2 power supply suited to the expected operating temperature range. The interconnecting power connector and power cable shall: Comply with local electrical code. Be suited to the expected operating temperature range. Meet the current and voltage rating for the FieldServer/Net Furthermore, the interconnecting power cable shall: Be of length not exceeding 3.05m (118.3 ) Be constructed of materials rated VW-1 or FT-1 or better.

FieldServer FS-X25 Start-Up Guide Page 4 of 12 If the unit is to be installed in an operating environment with a temperature above 65 C, it should be installed in a Restricted Access Area requiring a key or a special tool to gain access This device must not be connected to a LAN segment with outdoor wiring. 1.4 Specifications Power requirements Multi-mode power adapter: 5V-30VDC, 2.5W, 120VAC to 9VDC power supply is provided Physical Dimensions (LxWxD): Weight: Field Connections 4.55 x 4.50 x 1.35 in. (11.56 x 11.68 x 3.43 cm) 0.4 lb (0.18 Kg) Ethernet Port 10BaseT, 100BaseTX RJ45 (auto-sensing) Serial Port RS-232/RS-422/RS-485 switchable Up to 115K baud DB9 connector Drivers Drivers available for a wide range of Ethernet and serial protocols check driver information sheet Environment: Operating Temperature: Humidity: Approvals: -40-85 C (-40 185 F) 10-95% RH (non-condensing) UL FCC Class A, Part 15 CE EN55022, EN 55024 (Specifications subject to change without notice)

FieldServer FS-X25 Start-Up Guide Page 5 of 12 2 PRODUCT DESCRIPTION 2.1 Features Two DB-9 serial ports (defaulted to RS-485 unless specified differently at the time of purchase). Data communications speeds of 300 to 115200 baud supported. 10/100BaseT Ethernet LAN interface (auto-sensing) Easy configuration via text editor or spreadsheet and the available utilities. OPC server available Configuration utility Diagnostic utility System integration services available 2.2 LED Indicators Ethernet connection Tx/Rx communication activity Green LED 10/100 indicator LED on: 100 megabit connection LED off: 10 megabit connection Orange LED Link activity indicator LED on: Link active LED off: Link inactive Serial connection CPU communication activity Serial 1, Serial 2 CPU communication activity Flashes to indicate communication activity on the associated serial port Flashes once a second to indicate normal operation.

FieldServer FS-X25 Start-Up Guide Page 6 of 12 3 CONNECTION TO THE DEVICE 3.1 Serial Connection A DB-9 cable should be connected between the Serial port on the FS-X25 and the serial port of the target serial device. The Serial 1 port can be configured as either P1 (for RS-232 connection) or R1 (for RS-485 connection). Likewise the Serial 2 port can be configured as P2 or R2. Note that if a P1 and a R1 connection is declared, the one declared second will cause a configuration error on the error screen. 1 5 6 9 Figure 1: Serial Connection Ports 3.1.1 DB-9 Pinouts for RS-232 Connection Used to connect to DTE type devices. Typical null modem connection. (Used when Hardware RTS CTS flow control is required). 3 wire null modem connection (Used when Hardware RTS CTS flow control is not required). The cable used (serial cross-over cable) is available at any electronics retailer/distributor.

FieldServer FS-X25 Start-Up Guide Page 7 of 12 3.1.2 DB-9 Pinouts for RS-485 Connection Four Wire (full duplex multidrop) Two Wire (1/2 duplex) Note: The flow signals, RTS and CTS, should be connected as per diagram when unused to prevent loss of performance on the FieldServer. For users who do not wish to construct their own connector, we recommend using a DB-9 to screw block connector which can be purchased from L-Com, Inc. Item #: DGB9FT Ph: 1-800-341-5266 http://www.l-com.com/item.aspx?id=8141 3.2 Ethernet Connection The FS-X25 Ethernet port automatically senses an uplink connection, and may therefore be connected to a PC or a hub/switch using either a crossover cable (not supplied) or a direct Ethernet cable (supplied). Figure 2: Ethernet Connection port

FieldServer FS-X25 Start-Up Guide Page 8 of 12 4 OPERATION 4.1 Record Identification Data Each FS-x25 has a unique serial number and MAC address located on the underside of the unit. These numbers should be recorded as they may be required for technical support. Serial Number: MAC Address: 4.2 Power up the device Apply power to the device. Ensure that the power supply used complies with the specifications provided in Section 1.3 4.3 Install and Run the Utility Software Plug the supplied USB flash drive into the USB port on a PC/laptop. Open Index.html to get the menu of options, run the Install option and follow the installation instructions. Once installed, the FieldServer Utilities can be located in the Windows Start menu and as a desktop icon. 4.4 Connect the PC to the FieldServer over the Ethernet port. Use the supplied Cat5 UTP Ethernet cable to connect between the N1 port of the FieldServer and the hub. Refer to Section 3.2 for more information. Disable any wireless Ethernet adapters on the PC/Laptop, It is important that the PC/Laptop is on the same subnet as the FieldServer. The FS-x25 does not have a default IP address, but it will be 192.168.2.xxx. Refer to the FieldServer Utilities Manual for information on how to change the FieldServer s IP address. 4.5 Identification of the FieldServer on the Network Select Start Programs FieldServer Utilities; double click on the Ruiping Utility. The display should show FieldServer Name IP Number (192.168.2.X) FieldServerVersion If necessary, refer to Appendix A for troubleshooting tips.

FieldServer FS-X25 Start-Up Guide Page 9 of 12 4.6 Connection to the FieldServer Using RUI (Ruinet) Select Start Programs FieldServer Utilities, double click on the Remote User Interface icon or double click on the Remote User Interface Icon on the desktop. If Ruinet does not automatically bring you to the main menu, select the FieldServer by typing the 2-digit number to the left of the title name. If necessary, refer to Appendix A for troubleshooting tips. 4.7 Upload the Default Configuration The configuration of the FieldServer is provided to the FieldServer s operating system via a comma-delimited file called CONFIG.CSV. If ordered with the FieldServer, the custom configuration is installed; (Reference documentation FS-8790-XX). If a custom configuration is not purchased, a template config.csv is shipped on the FieldServer. Refer to the Configuration Manual and the Driver Manual(s) provided with the FieldServer for further information on configuration files. In the main menu of the Remote User Interface screen, type U to upload the configuration. Then type U again. The Remote User Interface Utility will fetch the default configuration and put it into the Configuration File folder (Start Programs FieldServerUtilities Configuration File folder). 4.8 Change the Configuration File to Meet the Application Refer to the Configuration Manual in conjunction with the Driver supplements for information on configuring the FieldServer. FieldServer Technologies offers training on this topic as well as a configuration service to complete this portion of the work. See www.fieldserver.com for specific details. 4.9 Download the updated Configuration file Before attempting to send files to the FieldServer, ensure that the files are in the configuration file folder. Refer to the FieldServer Utilities manual for further information. From the main menu, type "D" to access the download menu,

FieldServer FS-X25 Start-Up Guide Page 10 of 12 Type "L" (for local filename) to specify the name and extension of the file to be sent to the FieldServer. Hit <Enter> when done. The Remote User Interface Utility will automatically select config.csv for download of csv files. On rare occasions where other files need to be downloaded to the FieldServer type O for other files, then type R to specify the remote filename needed on the FieldServer. When satisfied that the correct file names are specified, Type "D" to download the file to the FieldServer. The Remote User Interface Utility will display a menu showing download progress. Note: the Remote User Interface Utility will indicate when download is complete. FieldServer before this message displays, as this could corrupt the FieldServer. DO NOT reset the Once download is complete, hit <Esc> to get back to the main menu and use the "!" option (or simply cycle power to the FieldServer) to put the new file into operation. Note that it is possible to do multiple downloads to the FieldServer before resetting it. Firmware created by FieldServer Technologies can be downloaded from the configuration file by simply typing F from the download menu. Note that FieldServer usually supplies firmware upgrades as an install.zip, for which a separate procedure is used, (See ENote 037 on the USB flash drive in a folder called Library). 4.10 Test and Commission the FieldServer Connect the FieldServer to the third party device(s), and test the application. From the main menu of Ruinet, type O to see the number of messages on each protocol. In case of problems, refer to Appendix A or the Troubleshooting Guide which can be found in the FieldServer Utilities directory under Documentation

FieldServer FS-X25 Start-Up Guide Page 11 of 12 Appendix A. Troubleshooting Tips Appendix A.1. Connection to the FieldServer Confirm that the network cabling is correct. Confirm that the computer network card is operational and correctly configured. Confirm that there is an Ethernet adapter installed in the PC s Device Manager List,, and that it is configured to run the TCP/IP protocol. Check the Ethernet OK LED Check the Activity LED on the Ethernet connection - this should flash at least once every 2 seconds if RUI is still running. Check that the netmask is correct. Go to Start Run Type in ipconfig The account settings should be displayed. Ensure that the IP address is 192.168.2.xxx and the netmask 255.255.255.0 Ensure that the PC and FieldServer are on the same IP Network, or assign a Static IP Address to the PC on the 192.168.2.0 network using the Remote User Interface Utility. Refer to the FieldServer Utilities manual for information. If using Windows XP or later, ensure that the firewall is disabled. Ensure that all other Ethernet cards active on the PC, especially wireless adapters are disabled. Refer to the FieldServer Troubleshooting Guide which can be found in the FieldServer Utilities directory under Documentation Appendix A.2. Technical support Before contacting Technical support to report an issue, go to Start Programs FieldServer utilities Tools and run the FST_Diag program. Take a log (See ENote0058 in the folder called Library on the USB Flash Drive). Send this log together with the configuration file to support@fieldserver.com for evaluation. Note that while all necessary documentation is shipped with the FieldServer on the USB flash drive, these documents are constantly being updated. Newer versions may be available on the web at www.fieldserver.com Appendix A.3. Material Service Orders (MSO) Procedure A FieldServer Sales Customer Representative can be contacted at 408-262-2299 x104 if a manufacturing defect is suspected. The serial number and reason for return of the product will be requested, and a MSO number will be supplied should the circumstances warrant a return. Note: 1. Please pack the item for repair securely and ship it prepaid and insured. FieldServer Technologies is not responsible for any damages caused to the product due to shipping. Note 2. FieldServer Technologies will not accept items for repair without an MSO number.

FieldServer FS-X25 Start-Up Guide Page 12 of 12 Appendix B. Limited Warranty FieldServer Technologies warrants its products to be free from defects in workmanship or material under normal use and service for two years after date of shipment. FieldServer Technologies will repair or replace without charge any equipment found to be defective during the warranty period. Final determination of the nature and responsibility for defective or damaged equipment will be made by FieldServer Technologies personnel. All warranties hereunder are contingent upon proper use in the application for which the product was intended and do not cover products which have been modified or repaired without FieldServer Technologies approval or which have been subjected to accident, improper maintenance, installation or application, or on which original identification marks have been removed or altered. This Limited Warranty also will not apply to interconnecting cables or wires, consumables or to any damage resulting from battery leakage. In all cases FieldServer Technology s responsibility and liability under this warranty shall be limited to the cost of the equipment. The purchaser must obtain shipping instructions for the prepaid return of any item under this warranty provision and compliance with such instruction shall be a condition of this warranty. Except for the express warranty stated above, FieldServer Technologies disclaims all warranties with regard to the products sold hereunder including all implied warranties of merchantability and fitness and the express warranties stated herein are in lieu of all obligations or liabilities on the part of FieldServer Technologies for damages including, but not limited to, consequential damages arising out of/or in connection with the use or performance of the product.