Single Channel RS-232/530/422/485/20mA Current Loop Interface

Similar documents
USB Director/USB RS-232 Hub

USB TO RS-232 OR RS-422/485 ISOLATED CONVERTER

USER MANUAL ME890A-R2 CATX DB9 LINE DRIVER 24/7 TECHNICAL SUPPORT AT OR VISIT BLACKBOX.COM RJ45 RJ45 5 VDC DB9-RS232

Copyright Black Box Corporation. All rights reserved.

Relay Output Card PCI 32 Outputs 32 Outputs/Kit

4K 2-PORT KVM SWITCH, USB C, DISPLAYPORT

ServSwitch DT DVI Pro

Model AC2000A DVI, Audio, RS-232 Extender with EDID Management

Copyright Black Box Corporation. All rights reserved.

Express Ethernet Switches

4-Port RS-232 PCI Serial Adapter 4-Port RS-232 HS PCI Serial Adapter

MicroNTU G.703 X.21 SEPTEMBER 1997 MT241A. MicroNTU G.703-X.21 CUSTOMER SUPPORT INFORMATION

Relay/Digital I/O Card-16

Connect up to four DB9 serial devices to a USB port.

Autosensing ISDN Matrix Switch

Connect one or two DB9 serial devices to a USB port.

HDMI 2.0 SPLITTER 1X4

Remote Port USB 2.0 -CAT5

Network Video Codec. Network VideoCodec CAMERA FEBRUARY 2001 AC700A CUSTOMER SUPPORT INFORMATION

DISPLAYPORT KVM DESKTOP SWITCHES

Copyright Black Box Corporation. All rights reserved.

Remote Port Wireless USB 2.0 User Guide

Extend DVI-D video and stereo audio up to 1.5 kilometers over a strand of single-mode fiber or distribute DVI-D and stereo audio to 32 displays.

Transmit USB 2.0 device signals up to 328 feet (100 m) over CAT5 cable, and power the extender locally or remotely.

PCI Plus Adapter RS-232 HS Serial PCI

DISPLAYPORT KVM DESKTOP SWITCHES

Line Share 120B FEBRUARY 1997 FX121A. Phone Line Manager 120B CUSTOMER SUPPORT INFORMATION

Copyright Black Box Corporation. All rights reserved.

RS-232/422/485 Single-Port PCI Card, Opto-Isolated

Linc Up Plus NT Linc Up Plus ATT Linc Up Plus RLM

4-Port Multimode Fiber Optic USB 2.0 Extender

Easily extend SuperSpeed USB 3.0 signals up to 330 feet (100 meters) over fiber.

Extend video and USB up to 328 feet (100 m) over CAT5e or better cable.

User Manual. Industrial Ethernet Extender for Extreme Temperatures - 10/100, 1-Port LB323A. Customer Support Information

4-Port Single-Mode Fiber Optic USB 2.0 Extender

Send up to four bidirectional data streams simultaneously over a single pair

Pure Home Networking Boxes

Extend Ethernet with full-duplex transmission up to 10.8 Mbps over two pairs of copper.

MARCH 2011 LB400A-R2 High Speed Ethernet Extender

ServSwitch DT Series USB/DVI/Audio KVM Switches

Provides one channel for Ethernet over existing voice-grade twisted-pair copper

4-PORT USB 2.0 FIBER EXTENDER

BLACK BOX. Easily extend both HDMI video and USB 2.0. up to 330 feet (100 m). ServSwitch KVM Extender, HDMI and USB 2.0 over CATx ACU2500A

Featuring enhanced biometric security with twofactor authentication, providing the perfect blend of security and simplicity.

Dual Port RS-232/422/485 Serial Interface

Break the 16-foot (5-m) USB distance barrier. This. up to 328 feet (100 meters) from a computer over CAT5 cabling.

Portable USB Modem Quick Start Guide

2-Port CAT5 USB 2.0 Extender with Local Power

Expand existing, leased line, polled networks without adding computer ports or communications links. Four- and eight-port models available.

USB Director/4-Port Hub

BLACK BOX. G.703 NTU w/10baset MARCH 2006 MT330A NETWORK SERVICES

User Manual. Industrial Ethernet Extender, 10/100, 1-Port LB320A. Customer Support Information

Express Ethernet Switch

Control your 4-post rack- or cabinet-mounted USB or PS/2 server with the compact, ServTray.

Four Port RS-232 Serial Interface

Extend HDMI signals over CATx cable.

USB Directors RS-232

Copyright Black Box Corporation. All rights reserved.

Copyright Black Box Corporation. All rights reserved.

JUNE 2000 SW613A SW613A-K

Easily extend USB 2.0 signals over an IP network or directly over a CATx link.

DSLAM Chassis and Software

Pwr. Pwr. Pwr. 4/16 Pwr 2. Rem.F. Rem.F. Rem.F. Token Tx. Link. Link. Link. Rx Al. Rx Al. Link. RX Al RemF. Link. Link. Rx Al. Rx Al.

Featuring enhanced biometric security with two-factor authentication, providing the perfect blend of security and simplicity.

RS-232 HS4 JANUARY 1997 IC131C CUSTOMER SUPPORT INFORMATION

User Manual. Chapter VS-2000-DEC. H.264 Decoder. Contact Information

Dual Port RS-232 Serial Interface

ServSwitch Universal Extender

twister 10MBPS MEDIA CONVERTERS

Clever Code-Operated Switch

Set up and manage a large, multichannel digital signage network that spans many locations.

PCMCIA Serial I/O Adapter

SCSI Fiber Optic Extenders

HDMI Audio Extractor with EDID Mgmt

PCMCIA Serial I/O Adapter

Store, transport, charge, and sync ipads.

Cable Inspector Cable Tester User Manual CICT. Customer Support Information

User s Manual. Gigabit Media Converter. Link 10/100/1000BASE-T to 100-/1000-Mbps SFP fiber connections. LGC220AE. Customer Support Information

2.4 GHz Wireless Remote Unit with Hookswitch

ServSwitch Wizard USB Extender

Manage and control up to 16 DVI and USB servers from your desktop.

2-Wire Short-Range DSL Line Driver (HDSL with 10BASE-T)

Compact Codirectional G.703 Converters

Chapter. HD View. AC3000A-R2 AC3016A-R2 Series

Voice Conferencing System

4- and 8-Line Caller ID

User Manual. Industrial Isolated Converter

User Manual v icompel Deployment Manager (IDM) v Customer Support Information

External ADSL USB Modem Users Manual

THE SERVSWITCH FAMILY

User Manual. Industrial Isolated Converter

Code Operated Switch II 4-Port Expansion Board

NOVEMBER 2000 SW625A-R2 SW626A-R2. Doc. No Rev. B

Copyright Black Box Corporation. All rights reserved.

2-Wire Short-Range DSL Line Driver (HDSL with V.35) (HDSL with X.21)

Copyright Black Box Corporation. All rights reserved.

Display standard single- or dual-link DVI input across four output monitors.

DKM TC KM SWITCH W/ HID PORTS

Black Box Tech Support: FREE! Live. 24/7. Great tech support is just 60 seconds away at or blackbox.com.

Voice Pro JANUARY 2001 FX700A FX701A FX702A CUSTOMER SUPPORT INFORMATION

Transcription:

Single Channel RS-232/530/422/485/20mA Current Loop Interface MARCH 2000 IC601C IC172C CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 Mail order: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com E-mail: info@blackbox.com

SINGLE CHANNEL RS-232/530/422/485/20MA C. L. INTERFACE TRADEMARKS USED IN THIS MANUAL All applied-for and registered trademarks are the propery of their respective owners. 2

FEDERAL COMMUNICATIONS COMMISSION AND CANADIAN DEPARTMENT OF COMMUNICATIONS RADIO FREQUENCY INTERFERENCE STATEMENTS FCC STATEMENT This equipment generates, uses, and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer s instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference. Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment. This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of the Canadian Department of Communications. Le présent appareil numérique n émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de classe A prescrites dans le Règlement sur le brouillage radioélectrique publié par le ministère des Communications du Canada. 3

SINGLE CHANNEL RS-232/530/422/485/20MA C. L. INTERFACE NORMAS OFICIALES MEXICANAS (NOM) ELECTRICAL SAFETY STATEMENT INSTRUCCIONES DE SEGURIDAD 1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado. 2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura. 3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser respetadas. 4. Todas las instrucciones de operación y uso deben ser seguidas. 5. El aparato eléctrico no deberá ser usado cerca del agua por ejemplo, cerca de la tina de baño, lavabo, sótano mojado o cerca de una alberca, etc.. 6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales que sean recomendados por el fabricante. 7. El aparato eléctrico debe ser montado a la pared o al techo sólo como sea recomendado por el fabricante. 8. Servicio El usuario no debe intentar dar servicio al equipo eléctrico más allá a lo descrito en las instrucciones de operación. Todo otro servicio deberá ser referido a personal de servicio calificado. 9. El aparato eléctrico debe ser situado de tal manera que su posición no interfiera su uso. La colocación del aparato eléctrico sobre una cama, sofá, alfombra o superficie similar puede bloquea la ventilación, no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orificios de ventilación. 10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores, registros de calor, estufas u otros aparatos (incluyendo amplificadores) que producen calor. 4

NOM STATEMENT 11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación, o como se indique en el aparato. 12. Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea eliminada. 13. Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos, poniendo particular atención a los contactos y receptáculos donde salen del aparato. 14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las recomendaciones del fabricante. 15. En caso de existir, una antena externa deberá ser localizada lejos de las lineas de energia. 16. El cable de corriente deberá ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo. 17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilación. 18. Servicio por personal calificado deberá ser provisto cuando: A: El cable de poder o el contacto ha sido dañado; u B: Objectos han caído o líquido ha sido derramado dentro del aparato; o C: El aparato ha sido expuesto a la lluvia; o D: El aparato parece no operar normalmente o muestra un cambio en su desempeño; o E: El aparato ha sido tirado o su cubierta ha sido dañada. 5

SINGLE CHANNEL RS-232/530/422/485/20MA C. L. INTERFACE Table of Contents Chapter Page 1. Specifications...7 2. Introduction...9 2.1 Features...9 2.2 Asynchronous Communications...10 2.3 RS-232...11 2.4 RS-422...11 2.5 RS-485...12 2.6 RS-530 and RS-449...12 2.7 RS-530/422/485 Line Termination...13 2.8 Current Loop...14 3. Address Selection...16 4. Interface Selection...18 5. Installation...24 Appendix. Block Diagram...26 6

1. Specifications CHAPTER 1: Specifications Number of Ports Maximum Data Distance Speed Protocol Connectors RS-485 Operation Communications Chip System Requirements Operating Temperature Storage Temperature Relative Humidity MTBF MTTR Single port Up to 50 feet (15.2 m) on RS-232; Up to 4000 feet (1219 m) on RS-530/422/485; Up to 10,000 feet (3048 m) on 20mA 19.2 Kbps (RS-232), IC601C: 115.2 kbps (RS-422/485), IC172C: 460.8 kbps and above (RS-422/485); Maximum data rate is dependent on software, CPU, and cable length Asynchronous only (1) DB25 male Two- or four-wire IC601C: 16550 UART; IC172C: 16950 UART ISA Bus 32 to 122 F (0 to 50 C) -4 to 158 F (-20 to 70 C) 90%, noncondensing > 150,000 hours < 0.25 hour 7

SINGLE CHANNEL RS-232/530/422/485/20MA C. L. INTERFACE Manufacturing Board Size Shipping Weight IPC 610-A CLASS-III standards adhered to with a 0.1 visual A.Q.L. and 100% Functional Testing; Boards are built to UL 94V0 rating and are 100% electrically tested. Boards are solder mask over bare copper or solder mask over tin nickel. Half card 2 lb. (0.9 kg) Power Supply Line +12 VDC -12 VDC +5 VDC Rating (ma) 50 50 270 8

CHAPTER 2: Introduction 2. Introduction The Single Channel RS-232/530/422/485/20mA Current Loop Interface provides one async serial port that can interface to RS-232, RS-530, RS-422, RS-485, and 20 ma Current Loop. The Current Loop Interface is designed for asynchronous-only operation: It implements only those signals associated with async operation. The DTE mode for RS-530 is assumed. The Current Loop Interface board (part number IC601C) uses the 16550 UART chip. This chip features programmable baud rate, data format, and interrupt control, and has a 16-byte transmit and receive FIFO. Part number IC172C uses the 16950 UART chip, which features a 128-byte FIFO. The Current Loop Interface can be addressed as COM1:, COM2:, or any other I/O address up to 3FF Hex, providing total compatibility with most communications software and languages. Drivers and receivers for RS-232, RS- 530/422/485, and 20mA Current Loop are provided on the serial port. 2.1 Features DB25 male connector mounted on board bracket. Port can be addressed as COM1:, COM2:, COM3: (3E8 Hex), COM4: (2E8 Hex) or any other I/O address up to 3FF Hex. Interrupt Request (IRQ) lines are jumper selected for IRQ 9/2, 3, 4, 5, and 7 Interrupt can be shared with other sharable interrupts. RS-232C Interface with all standard PC signals (TD, RD, RTS, CTS, DSR, DCD, DTR, RI) or RS-530/422 interface. Serial-port interface (RS-232, RS-530/422/485, 20mA Current Loop) is determined by jumper selection. Utility software is included for diagnostics. No additional line driver or converter is needed. 9

SINGLE CHANNEL RS-232/530/422/485/20MA C. L. INTERFACE 2.2 Asynchronous Communications Asynchronous communications is the standard means of serial data communication for IBM compatible PCs. Serial data communications implies that individual bits of a character are transmitted consecutively to a receiver that assembles the bits back into a character (see Figure 2-1). Data rate, error checking, handshaking, and character framing (start and stop bits) are pre-defined and must correspond at both the transmitting and receiving ends. Serial asynchronous communications is typically implemented with a Recommended Standard (RS). The standard usually defines signal levels, maximum bandwidth, connector pinout, supported handshaking signals, drive capabilities, and electrical characteristics of the serial lines. The following sections briefly describe some of the more common communication standards. Voltage levels that are stated are typical and may vary with line characteristics. All interfaces accept a range of acceptable electrical and physical parameters and may even operate in excess to the specified standard under certain line characteristics. The full specification for each standard is available from almost any dealer of engineering documents. For a more detailed explanation of asynchronous serial communications, refer to the book Technical Aspects of Data Communications by John E. McNamara, published by Digital Press (DEC) 1982. 1 0 Idle state of line 5 to 8 Data Bits Odd, Even or Unused P BIT STOP 1 1.5 2 Remain Idle or next start bit Figure 2-1. Asynchronous Timing Diagram. 10

CHAPTER 2: Introduction 2.3 RS-232 Probably the most widely used communication standard is RS-232. This implementation has been defined and revised several times and is often referred to as RS-232C or EIA-232. RS-232 most commonly uses either a DB25 or a DB9 connector. It is capable of operating at data rates up to 20 Kbps for a distance of up to 50 feet (15.2 m). The absolute maximum data rate may vary due to line conditions and cable lengths. RS-232 often operates at 38.4 Kbps at very short distances. The voltage levels defined by RS-232 range from -12 to +12 volts. RS-232 is a single-ended interface. This means that a single electrical signal is compared to a common signal (ground) to determine binary logic states. A voltage of +12 volts (usually +8 to +10 volts) represents a binary 0, and -12 volts (-8 to 10 volts) denotes a binary 1. Table 2-1. RS-232 Connector Pinouts Signal Name Pin # Mode GND Ground 7 RD Receive Data 3 Input RS-232 CTS Clear To Send 5 Input RS-232 DSR Data Set Ready 6 Input RS-232 DCD Data Carrier Detect 8 Input RS-232 RI Ring Indicator 22 Input RS-232 DTR Data Terminal Ready 20 Output RS-232 TD Transmit Data 2 Output RS-232 RTS Request To Send 4 Output RS-232 11

SINGLE CHANNEL RS-232/530/422/485/20MA C. L. INTERFACE 2.4 RS-422 RS-422, unlike RS-232, is a differential interface that defines voltage levels and driver/receiver electrical specifications. On a differential interface, logic levels are defined by the difference in voltage between a pair of outputs or inputs. In contrast, a single-ended interface, for example RS-232, defines the logic levels as the difference in voltage between a single signal and a common ground connection. Differential interfaces are typically more immune to noise or voltage spikes that may occur on the communication lines. Differential interfaces also have greater drive capabilities that allow for longer cable lengths. RS-422 is rated up to 10 Mbps and can have cabling 4000 feet long. RS-422 also defines driver and receiver electrical characteristics that will allow one driver and up to 32 receivers on the line at once. RS-422 signal levels range from 0 to +5 volts. RS-422 does not define a physical connector. 2.5 RS-485 This interface is very similar to RS-422 is several ways. RS-485 is a differential interface that allows cable lengths up to 4000 feet and data rates up to 10 Mbps. The signal levels for RS-485 are the same as those defined by RS-422. RS-485 has electrical characteristics that allow for 32 drivers and 32 receivers to be connected to one line. This interface is ideal for multi-drop or network environments. RS-485 s tri-state driver (not dual-state) will allow the electrical presence of the driver to be removed from the line. The driver is in a tri-state or high impedance condition when this occurs. Only one driver may be active at a time and the other driver(s) must be tri-stated. The output modem-control signal Request to Send (RTS) controls the state of the driver. Some communication software packages refer to RS-485 as RTS enable or RTS block-mode transfer. RS-485 can be cabled in two ways: two-wire and four-wire mode. Two-wire mode does not allow for full-duplex communication. Two-wire mode requires that data be transferred in only one direction at a time and the two transmit pins should be connected to the two receive pins (Tx+ to Rx+ and Tx- to Rx-). Four-wire mode will allow full-duplex data transfers. RS-485 does not define a physical connector, a connector pinout, or a set of modem control signals. 12

CHAPTER 2: Introduction 2.6 RS-530 and RS-449 RS-530 and RS-449 (a.k.a. EIA-530 and EIA-449) are similar to RS-422 and RS- 485 in the fact that they are differential interfaces, but these two standards provide a specified pinout that defines a full set of modem-control signals that can be used for regulating flow control and line status. RS-449 is defined on a standard DB37 connector; RS-530 is backward-compatible and is replacing RS- 449. RS-530 is defined on a DB25 connector. These two interfaces do not define an electrical specification, but they do provide a means of selecting a standard cabling interface. Table 2-2. RS-530/422/485 Connector Pinouts Signal Name Pin # Mode GND Ground 7 RDB RX+ Receive Positive 16 Input RS-422 RDA RX- Receive Negative 3 Input RS-422 CTSB CTS+ Clear To Send Positive 13 Input RS-422 CTSA CTS- Clear To Send Negative 5 Input RS-422 DSRB DSR+ Data Set Ready Positive 22 Input RS-422 DSRA DSR- Data Set Ready Negative 6 Input RS-422 DCDB DCD+ Data Carrier Detect Positive 10 Input RS-422 DCDA DCD- Data Carrier Detect Negative 8 Input RS-422 TDB TX+ Transmit Positive 14 Output RS-422 TDA TX- Transmit Negative 2 Output RS-422 RTSB RTS+ Request To Send Positive 19 Output RS-422 RTSA RTS- Request To Send Negative 4 Output RS-422 DTRB DTR+ Data Terminal Ready Positive 23 Output RS-422 DTRA DTR- Data Terminal Ready Negative 20 Output RS-422 2.7 RS-530/422/485 Line Termination Typically, each end of the RS-530/422/485 bus must have line-terminating resistors. A 100-ohm resistor is across each RS-530/422/485 input in addition to a 1-Kohm pull-up/pull-down combination that biases the receiver inputs. 13

SINGLE CHANNEL RS-232/530/422/485/20MA C. L. INTERFACE The RS-530 specification calls for a 100-ohm 1/2-watt resistor between the signal ground and the chassis ground. On the IBM PC, these two grounds are already connected together, so this resistor is omitted. 2.8 Current Loop This communication specification is based on the absence or presence of current, not voltage levels, over the communication lines. The logic of a Current-Loop communications circuit is determined by the polarity of the current path (typically + or - 20mA). When referring to the specification, the current value is usually stated (for example, 20mA Current Loop). Current Loop is used for point-to-point communication and there are typically two current sources, one for transmit and one for receive. These two current sources may be located at either end of the communication line. To ensure a proper current path to ground, or loop, the cabling of two current loop communication ports will depend on the location of the current sources. Current Loop is normally good for data rates up to 19.2 Kbps. This limitation is due to the fact that the drivers and receivers are usually optically isolated circuits that are inherently slower than non-isolated equivalent circuits. Table 2-2. 20mA Current Loop Pinouts Signal Name Pin # Current Source #1 21 TD+ Transmit Data Positive 25 RD+ Receive Data Positive 12 Current Source #2 9 TD- Transmit Data Negative 24 RD- Receive Data Negative 11 Ground 7 To perform a loopback test in Current Loop, connect pins 21 to 25, 24 to 12, and 11 to 7. 14

CHAPTER 2: Introduction CURRENT-LOOP CONNECTIONS Passive Connection Loop Input: 12 RD+ Customer Current Source 11 RD- Customer TD+ output Loop Output: 25 TD+ Customer Current Source 24 TD- Customer RD+ Input Active Connection 12v 21 Loop Input (Receive Loop) Rx+ Tx- Rx- 12 11 Tx+ GND 7 9 Loop Output Tx+ 25 Tx- 24 Rx+ GND 7 (Transmit Loop) Rx- 15

SINGLE CHANNEL RS-232/530/422/485/20MA C. L. INTERFACE 3. Address Selection The Single Channel RS-232/530/422/485/20mA Current Loop Interface occupies 8 consecutive I/O locations. DIP-switch SW1 sets the base address for the Current Loop Interface. Be careful when selecting the base address, since some selections conflict with existing PC ports. The following table shows several examples that usually do not cause a conflict. Table 3-1. Address Selection Address Binary Switch Setting Hex A9 A0 1 2 3 4 5 6 7 280-287 1010000XXX OFF ON OFF ON ON ON ON 2A0-2A7 1010100XXX OFF ON OFF ON OFF ON ON 2E8-2EF 1011101XXX OFF ON OFF OFF OFF ON OFF 2F8-2FF 1011111XXX OFF ON OFF OFF OFF OFF OFF 3E8-3EF 1111101XXX OFF OFF OFF OFF OFF ON OFF 300-307 1100000XXX OFF OFF ON ON ON ON ON 328-32F 1100101XXX OFF OFF ON ON OFF ON OFF 3F8-3FF 1111111XXX OFF OFF OFF OFF OFF OFF OFF Typically COM1: = 3F8h; COM2: = 2F8h; COM3: = 3E8h; COM4: = 2E8h. The following illustration shows the correlation between the DIP-switch setting and the address bits used to determine the base address. A9 A3 EN ON 1 2 3 4 5 6 7 8 16

CHAPTER 3: Address Selection In this example, the address 300 hex through 307 hex is selected. 300 hex equals 11 0000 0XXX in binary representation. NOTE Setting the switch On or Closed corresponds to a 0 in the address, while leaving it Off or Open corresponds to a 1. Port Enable/Disable Each port on the Current Loop Interface can be enabled or disabled with switch position 8 on the DIP switch. The port is enabled with the switch On or Closed and disabled when Off or Open. If any port is disabled, be sure to also disable the interrupt request for that port by removing the IRQ jumper (see Figure 4-6). 17

SINGLE CHANNEL RS-232/530/422/485/20MA C. L. INTERFACE 4. Interface Selection The board contains several jumper straps for each port which must be set for proper operation. E2 connects the DB25 connector (P1) to either RS-232 interface drivers and receivers, or RS-422/485 interface drivers and receivers, or the Current Loop receiver interface. Figure 4-1 shows the two settings for each port. IMPORTANT! On E2 you must move all eight push-on jumpers. This is required to completely isolate RS-232 signals from RS-422/485 and vice-versa. On E1, however, there are several jumper options. RS-422/485/530 18 Figure 4-1. Header E2 options.

CHAPTER 4: Interface Selection E1 jumper setting for RS-232 interface option: GND EN CL RI DCD DSR CTS RD B A Figure 4-2. Header E1 (RS-232 Interface Option). GND Ground A selects normal ground for RS-232. EN Enable A (not applicable to RS-232). CL Current Loop A selects RS-232 Receive Data. RI Ring Indicator A enables RI, B sets it true. DCD Data Carrier Detect A selects RS-232. DSR Data Set Ready A selects RS-232. CTS Clear To Send A selects RS-232. RD Receive Data A selects RS-232. 19

SINGLE CHANNEL RS-232/530/422/485/20MA C. L. INTERFACE E1 Jumper setting for RS-530 and RS-422: GND EN CL RI DCD DSR CTS RD B A Figure 4-3. Header E1 (RS-530/422 Interface Option). GND Ground B selects 100-ohm ground for RS-530/422. EN Enable A position for RS-530. CL Current Loop A selects RS-530 Receive Data. RI Ring Indicator (not used on RS-530) B sets it true. DCD Data Carrier Detect B selects RS-530. DSR Data Set Ready B selects RS-530. CTS Clear To Send B selects RS-530. RD Receive Data B selects RS-530. 20

CHAPTER 4: Interface Selection E1 Jumper setting for RS-485: RS-485 GND EN CL RI DCD DSR CTS RD B A Figure 4-4. Header E1 (RS-485 Interface Option). GND Ground B selects 100-ohm ground for RS-485. EN Enable driver with RTS B A is always enabled. CL Current Loop A selects RS-485 Receive Data. RI Ring Indicator (not used on RS-485) B sets it true. DCD Data Carrier Detect B selects RS-485. DSR Data Set Ready B selects RS-485. CTS Clear To Send B selects RS-485. RD Receive Data B selects RS-485. E1 position EN is used to enable the driver with RTS. To permanently enable the driver (normal RS-422 point-to-point mode), remove jumper EN at E1. Failure to correctly set this jumper can cause transmitter contention problems, preventing operation by any nodes on the network. 21

SINGLE CHANNEL RS-232/530/422/485/20MA C. L. INTERFACE E1 position GND determines whether the board provides a direct ground connection (as in RS-232 and most RS-422), or a 100-ohm high-impedance ground. The 100-ohm high-impedance ground is normally used in RS-485 (and some RS-422) to avoid ground-loop currents with long cables. E1 Jumper setting for 20 ma Current Loop: GND EN CL RI DCD DSR CTS RD B Figure 4-5. Header E1 (20 ma Current Loop Interface Option). A GND Ground A selects normal ground for Current Loop. EN N/A CL Current Loop B selects Current Loop receive data. RI Ring Indicator (not used), B sets it true. DCD DSR CTS N/A N/A N/A RD Receive Data. Remove or Float on one pin for Current Loop. 22

CHAPTER 4: Interface Selection E3 selects the interrupt request for the serial port. If COM1: is selected, this jumper must be on the IRQ4 setting. If COM2: is selected, this jumper must be on IRQ3. Consult your particular software for IRQ selection. If no interrupt is desired, remove the jumper. M N 7 5 4 3 2 Figure 4-6. Header E3 IRQ Selection. E3 Positions M and N allow the user to select a single interrupt per port mode or a shared interrupt mode. The N selects the single-interrupt-per port mode, which is the typical DOS, OS/2, and Windows 3.1 mode of operation. The M selects the shared interrupt mode, which allows more than one port to access a single IRQ, and indicates the inclusion of a 1K ohm pull-down resistor required on one port when sharing interrupts. This mode is used by software that requires COM3: and COM4: to share interrupts with COM1: and COM2: or in an OEM configuration to support a specific software application. NOTE IRQ2 on AT class machines is not available. IRQ9 is substituted in place of IRQ2. To select IRQ9, place the jumper on the IRQ2 position. 23

SINGLE CHANNEL RS-232/530/422/485/20MA C. L. INTERFACE IMPORTANT You MUST set up the operating system BEFORE you physically install the Card. 5.1 Software Installation 5. Installation If you are installing an ISA adapter in DOS, OS/2, or QNX, please refer to the appropriate directory on one of the Serial Utilities Disks for instructions. 5.1.1 WINDOWS 3.1X Please refer to the /WINDOWS sub-directory on the Serial Utilities Diskette for help files and current information on the installation of the Card in this operating environment. 5.1.2 WINDOWS 95/98 USERS For the ISA card, run setup on disk two of the Serial Utilities Diskettes before installing the card. Make note of the resources that Windows assigns the adapter, and set the adapter to match those resources. Power down the computer and install the adapter as described in Section 5.2. If you wish to change any resources assigned to the adapter, refer to the help file installed in the Black Box folder in the Start, Programs menu. 5.1.3 WINDOWS NT For the ISA card, run setup on disk two of the Serial Utilities Diskettes before installing the card. After installing the software, refer to the help file that automatically comes up for installation instructions. 24

CHAPTER 5: Installation 5.2 Hardware Installation To install the card: Remove the PC case. Remove the screw holding the blank metal slot cover. Remove the blank metal slot cover. Gently insert the board. Replace the blank metal slot cover. Replace the screw. Replace the PC case. If you wish to change any resources assigned to the adapter, refer to the help file installed in the Black Box folder in the Start, Programs menu. 25

SINGLE CHANNEL RS-232/530/422/485/20MA C. L. INTERFACE Appendix. Block Diagram R2 R4 R5 C2 Y1 C1 U3 74LS04 U1 R1 C3 R3 U4 75174 U2 D1 R6 13 25 C4 R7 SW1 ON=0 C8 A9 16650 U6 74LS244 C5 C6 A3 U10 74LS682 A31 E1 GND U7 EN CL 1489 RI DSR CTS U8 RD B A 74LS125 D2 R8 E3 M N 7 5 4 3 2 IRQ P2 DCD C7 C9 1 1 1 U5 145406 RP1 RP3 75173 U9 U11 74LS245 E2 RP2 RS-422 C10 C11 RS-232 A1 C12 1 14 P1 For in-depth schematic detail, call for technical support. 26

Copyright 2000. Black Box Corporation. All rights reserved. 1000 Park Drive Lawrence, PA 15055-1018 724-746-5500 Fax 724-746-0746