RS232 - TCP / IP Converter

Similar documents
Universal Weather Display Software UWDS11

Manual. GSM900 Module. for. Reinhardt Weather Stations. REINHARDT System- und Messelectronic GmbH

TigerStop Ethernet-to-Serial Converter Installation & User s Guide v4.2

8 TS4-DDH T i g e r S t o p M a n u a l D a t a D o w n l o a d i n g. May 2006 Version 3.5 ~ 4.72 Hardware

KNX/EIB Push button sensor 3 Plus F Safety instructions. 2 Device components. 3 Function

Quick Installation Guide

Users Manual STP-103II. Thermal Printer Rev

GSM-X. Communication module. Quick installation guide. Full manual is available on Firmware version 1.02 gsm-x_sii_en 08/18

FREQUENCY DRIVES ADJUSTABLE SERIES 9000 AF DRIVES. SVLoad Application. Loading Application and Option Software. Instruction Sheet

VISY-X. Technical Documentation. MOXA Ethernet Converter Installation and configuration. Edition: Version: 1 Article No.

3 Input Multiplexer Operation Manual

installation manual SALES AND ADMINISTRATION (toll free)

User Manual Revision English

MOXA VPort 2110/2140/2141 Video Server Quick Installation Guide

SerialSwitch Network. Installation Guide

XPort Development Kit Quick Start Guide. XPort Quick Start Guide

ProjectorNetTM Adapter Quick Start Guide

Connecting a CNC to a PC wireless over WiFi

NetCom Plus 811 POE. Contact Online. More Pictures. Click on the thumbnails for the large picture. Overview

2001 by NEC America. All Rights Reserved. Printed in U.S.A.

Aarlogic TER-GX910. Product description. Rev.9 17/03/2013

Bus coupler 3 Bus coupler 3 external sensor Order No

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

USER MANUAL GIOVE AC5

NetCom Plus 211. Contact Online. More Pictures. Click on the thumbnails for the large picture. Overview

SFU Connection Cables

Advanced Graphical Interface, AGI 100

Manual. Sensors. with Datalogger. REINHARDT System- und Messelectronic GmbH. Bergstr. 33 D Dießen-Obermühlhausen

15P0102Q2 SINUS PENTA KEYPAD CONNECTED TO NETWORK RS485 USERS MANUAL

User Manual EzLogger WiFi Ver 02

SeriBox. antrax Datentechnik GmbH

Select a Data Communication Interface

BNI IOL Z026 BNI IOL-302-S01-Z026 User s Guide

BNI IOL Z013 BNI IOL-302-S01-Z013. User s Guide

BNI IOL Z026 BNI IOL-302-S01-Z026. User s Guide

I/O SIGNAL CONDITIONER

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

GT- IRDM-9603 Product description Rev. 2 17/06/2014

Installation and Operating manual. W e b M a s t e r

Quick Installation Guide

QUADIMODO. Quad-Band IP68 GSM MODEM. Quad Band for Worldwide Use. IP68 Enclosure Submersible. Voice / Fax / SMS and Data. GPRS Class B Class 10:

BNI IOL K023 BNI IOL K023. User s Guide

NetCom Plus 113. Contact Online. More Pictures. Click on the thumbnails for the large picture. Overview

Classic Kiosk. User Guide. Before operating the unit, please read this manual thoroughly, and retain it for future reference

Series STA DIGITAL TORQUE TOOL TESTERS. User s Guide

ICM-25 INPUT CONTROL MODULE, 25 INPUTS RS-232(SERIAL) OUTPUT

4x4 HDMI2.0 Matrix Support YUV4:4:4, 18Gbps, HDR. Operating Instruction

USER MANUAL FOR FIOA-0402-U-16

IPCB42501 / IPCB42551

ENGINEERING G. M. B. H. ENGINEERING MAKES THE DIFFERENCE

Introducing QuickSyn Interface Accessories

SCHMIDT Sensor interface PROFIBUS Instructions for use

Docking station Order no Operation and installation instructions. 1 Safety instructions. 2 Structure of the device.

Serial/Ethernet Converter

62532 (EN649) Ethernet Adapter

UniMod Ethernet. LAN-Modem. Bär Industrie-Elektronik GmbH Siemensstr. 3 D Fürth Germany

USBoard. Operating Manual. Version November USBoard-OperatingManual Neobotix GmbH all rights reserved 1 of 25

Chameleon Stand-alone

Installation manual plugs and connectors with screw connection (16/32 A)

WiFi to RS-422/485 adapter user manual

Printer Interface (6370) Setup. Replaces discontinued Printer Interface (4370)

INSTRUCTION MANUAL. EP1000A E-Port. Ethernet Interface Port for Micro-DCI DataLink and Modbus. PN26010, Rev.1

Hardware Manual RM CANview

RTU560 Remote Terminal Unit Connections and Settings

NetCom Plus 413 POE. Contact Online. More Pictures. Click on the thumbnails for the large picture. Overview

Bluetooth RS-232 Dongle. User s Manual BTS-100

User Manual Revision English

Series ST. User s Guide DIGITAL TORQUE TOOL TESTERS. .com. Series ST Torque Tool Testers. User s Guide

Operating Instructions

Manual DTM Digital Pressure Transmitter

(see also technical drawings) Width with inlay

Quick Installation Guide

User Manual Revision English

USB/RS232 TO cctalk COMMUNICATION BOARD Technical Information

IntesisBox Modbus Server Panasonic

8 Button IP Controller Installation and Operation Manual AV-IP-C8-WH

Expert Power Control NET 4x DIN

BNI USB A501. User s Guide

USER MANUAL FOR GS100/GS1003G

Installation and User Guide

C9900-P208 and C9900-P209

CPCI-ASIO4 CAN - RS-232, RS-422, RS-485

Channel Switch CS. General Operating, Maintenance and Installation Manual

8x8 HDMI2.0 Matrix Support YUV4:4:4, 18Gbps, HDR. Operating Instruction

Flux Capacitor Serial-to-IR Converter Just Add Power HD over IP Page1. IR Dongle. a.k.a. FLUX CAPACITOR. Revised

How to configure RS232 for SMP players

DuoFern Multiple Wall Controller

BNI IOL-104-S01-Z012-C02

INSTRUCTION MANUAL V1. 2x A

CMU 100 RS485 to Ethernet Converter User Manual CMU 100 / CMU 100 / 1.M.9 CMU 100 / 1.L.9 CMU 100 / CMU 100 / 7.M.9 CMU 100 / 7.L.

DWL-1750 TM. This product can be set up using any current web browser, i.e., Internet Explorer or Netscape Navigator. Wireless Bridge / Router

ESPSX3 Ethernet Serial Port Server X 3 Users Guide

MAGUIRE G2-ES Configuration Instructions for Ethernet to Serial Converter Model: Moxa NPort 5110 Serial Device Server

MC-12 Software Installation Instructions

Upgrading Firmware for the CETAC ASXPRESS PLUS Rapid Sample Introduction System

XPress DR+W Quick Start Guide

TORRIX RS485. Technical Documentation. with MODBUS Protocol. Edition: Version: 2 Art. no.:

Applikationen & Tools. Safe switching of IO-Link motor starter combination 3RA27 with safety relay 3SK1. IO-Link. FAQ November 2012

User s Manual BTS1009C. Bluetooth to Serial Adapter. SUNIX Co., Ltd.

WiFi to RS-232 adapter user manual

Transcription:

Manual RS232 - TCP / IP Converter for Reinhardt Weather Stations REINHARDT System- und Messelectronic GmbH Bergstr. 33 D-869 Dießen-Obermühlhausen Tel. 0896/93400 Fax 0896/7005 u. 44 E-Mail: wetter@reinhardt-testsystem.de WEB: http://www.reinhardt-testsystem.de

Table of contents Manual RS232 - TCP/IP Converter for Weather Stations Table of contents For compliance...4. Usage...4.2 Safety instructions...4.3 Mounting...4 2 Commissioning...5 2. Hardware Installation...5 2.2 Software Installation...5 2.3 Configuration of RS232 - TCP/IP Converter...6 2.3 Configuration of the RS232 - TCP/IP converter via the serial port (RS-232)...7 2.32 Configuration of the RS232 - TCP/IP converter via the internal serial port (RS-232)... 8 2.33 Connection of an external RS232-422 converter...8 2.4 Tunnelling with RS232 - TCP/IP Converter...9 2.5 Changing the baud rate...0 3 Connecting the RS232 - TCP/IP Converter to an existing cable... 4 Connection schematics... 4. Standard connection... 4.2 Afterwards connection to an existing weather station...2 4.3 Connection with RS-422 port...3 RS232-TCPIP_e.p65 Page 2 Bergstr. 33 869 Diessen-Obermühlhausen Postfach 2 4 D-86908 Diessen Tel. 0896/93400

RS232 - TCP/IP Converter indoor for Reinhardt weather stations Power / Data Network TCP/IP RS232-TCPIP_e.p65 Page 3 Fax: 0896/7005 E - Mail: wetter@reinhardt-testsystem.de Web: http://www.reinhardt-wetterstationen.de

For compliance. Usage The RS232 - TCP/IP-Converter for all Reinhardt Weather Stations and Sensors (MWS 9-5, MWS 5MV, MWS6 and Sensors with datalogger) consist of a XPORT-module, switcheing power supply for best efficiency and level converters for the RS232 serial port. The RS232 - TCP/IP-Converter is built for connecting any Reinhardt weather station and converting it's serial protocol into a network protocol (TCP/IP) to integrate it into a network with an exclusive IP-address. This address is established by the integrated XPORT module as well as a selectable port (000 by default). To change the IP-adrress you easy can do this opening the module's Web-interface. With this IP-address the weather station can be operated in the whole network or the internet. Caution! Only one client can have access to the weather station over the IP-address, never more at the same time. Maximum supply voltage is 24 VDC!.2 Safety instructions The instruments are manufactured in accordance with modern technical standards and can be operated without danger when used as directed. Damage caused by non-observance of this operating manual can lead to forfeiture of warranty. is not liable for subsequent damage. is not liable for damage of items or persons caused by improper handling or non-observance of the safety instructions! In such cases any guarantee claims shall become null and void. Dear customer, the following safety and hazard notices not only protect your health, but also the appliance. Please read the following points carefully. Do not leave the packaging material lying around. These parts are dangerous toys in the hands of children..3 Mounting Mounting of the RS232 - TCP/IP-Converter outdoor is performed by clamping it onto a " pipe. The indoor converter is placed near a router or a switch. RS232-TCPIP_e.p65 Page 4 Bergstr. 33 869 Diessen-Obermühlhausen Postfach 2 4 D-86908 Diessen Tel. 0896/93400

2 Commissioning 2. Hardware Installation The RS232 - TCP/IP-Converter is connected to the standard cable of you weather station or sensor (7-pole connector and additional power supply unit) and supplied by it. The weather station is also connected directly to the RS232 - TCP/IP-Converter (second 7-pole connector) by a patch cable (pins,3,4, and 5 are connected through). Both 7-pole connectors are identical and can be mixed up without damaging the module. The network cable (patch cable) connecting a router or switch is plugged into the third connector. Please do not use any tools to fasten the connectors in order to avoid the connectors working themselves loose due to too big force when fastening the connectors!! 2.2 Software Installation For operating the weather station a comfortable software which allows storing data via COM-port or via the RS232 - TCP/IP-Converter is included. Using the RS232 - TCP/IP-Converter enables the software to store data via a network or the internet. For using internet connection you use a provider like DYNDNS. After creating an account on the provider's siteyou can establish a connection between your DYNDNS-client and the weather station via your router nad get the data of your weather station worldwide. PLEASE NOTE THAT ONLY ONE CLIENT CAN GET ACCESS TO THE WEATHER STATION, NOT MORE AT THE SAME TIME. Installation of the weather software is described in the respective manuals. RS232-TCPIP_e.p65 Page 5 Fax: 0896/7005 E - Mail: wetter@reinhardt-testsystem.de Web: http://www.reinhardt-wetterstationen.de

2.3 Configuration of RS232 - TCP/IP Converter To change the settings of your RS232 - TCP/IP-Converter on the supplied CD you'll find the DeviceInstaller from Lantronix, the documentation of the XPORT-05 module, which is built in the RS232 - TCP/IP-Converter and also a link to Lantronix, where you can find the latest documentation and firmware for your XPORT-05 module. https://www.lantronix.com/products/xport/#docs-downloads To perform this you connect your RS232 - TCP/IP-Converter to any router or switch in your network (with a patch cable) and let the Device Installer search for components in your network. When finished the search please select the XPORT-05 module. In the next window only accept, no password is needed. Now you should see the Web-Interface of your RS232 - TCP/IP-Converterand you can perform your desired settings. For details please read the respective manuals of LANTRONIX also stored on the CD. RS232-TCPIP_e.p65 Page 6 Bergstr. 33 869 Diessen-Obermühlhausen Postfach 2 4 D-86908 Diessen Tel. 0896/93400

2.3 Configuration of the RS232 - TCP/IP converter via the serial port (RS-232) If the RS232 - TCP/IP-Converter is not yet set on your desired IP-address and you cannot get access to the Web-Interface, you may perform the settings via the COM-port. To perform this please connect the RS232 - TCP/IP-Converter with the ready made cable to a COM-port of your computer with a null modem adaptor. With RS-422 you invert the 4 data cables of the RS232_RS422_converter to realize the null modem function instead the use of a null modem adaptor. Then start a terminal software, i.e. hypertrm with 9600baud, no parity, 8 bits, no handshake. Then insert the PSU to the mains and press 3 times a lower case x within the next 5 seconds. The following screen will appear: After this please press the ENTER key within the next 3 seconds. The menu shown below will appear and you can perform the desired settings. RS232-TCPIP_e.p65 Page 7 Fax: 0896/7005 E - Mail: wetter@reinhardt-testsystem.de Web: http://www.reinhardt-wetterstationen.de

2.32 Configuration of the RS232 - TCP/IP converter via the internal serial port (RS-232) If your TCP/IP converter is eqipped with a RS-422 port you may perform the settings via the serial port RS-232 also with the internal serial port. To perform please remove the top cover and connect a serial : cable with 2 female 9-pole connectors to the right internal serial port. The other connector you plug into the serial poer of a computer. CAUTION: Only the : cable is allowed to be connected to the serial port. The powering cable or the cable to the weather station must not be connected to a serial port when configuring the unit! Then you perform as described under 2.3 Bestückungsseite 9 8 7 6 5 4 3 2 + + + + K Bestückungsseite Interne serielle Schnittstelle zur Konfiguration 9 8 7 6 5 4 3 2 K K K K + + + + 4 5 6 7 nc 2 3 4 5 6 7 nc 2 3 2 2.33 Connection of an external RS232-422 converter Data mode (normal mode) Nullmodem mode (for settings via CLI) RS232-TCPIP_e.p65 Page 8 Bergstr. 33 869 Diessen-Obermühlhausen Postfach 2 4 D-86908 Diessen Tel. 0896/93400

2.4 Tunnelling with RS232 - TCP/IP Converter You can use two RS232 - TCP/IP-Converters as a cable replacement tunneling weather data through a network. This means that you connect the first RS232 - TCP/IP-Converter to the COM-port of your weather station and to a router / switch of your network. A second RS232 - TCP/IP-Converter is connected to a router / switch at another place in your network a converts the data back to a RS232 string to connect a weather display with serial port for example. To perform this you need to configure your RS232 - TCP/IP-Converters for tunnel operation. Below you can see an example for the respective settings in the Web-Interface: Further information you'll find in the documentation of the XPort. RS232-TCPIP_e.p65 Page 9 Fax: 0896/7005 E - Mail: wetter@reinhardt-testsystem.de Web: http://www.reinhardt-wetterstationen.de

2.5 Changing the baud rate The TCP/IP-Converter is set to 9600 baud by default. Also the connected weather station is set to 9600 baud. You can change the baud rate by sending the command!bx to the weather station, where x is the code for the baud rate (5=9600Baud, 6=9200, 7=38400, 8=57600 und 9=5200). Please refer to the respective weather station's manual to check which baud rates are supported by your weather station. After changing the baud rate of the weather station you need to change the TCP/IP-converter's baud rate too. To perform please access the converter's WEB interface by inserting the converter's IP address in a browser or using the Lantronix Device Installer (on the weather CD). The baud rate can be changed under "Serial Settings" and "Baud Rate". After changing the baud rate choose "OK" and then "Apply Settings". The TCP/IP-converter now restarts and saves the new baud rate. RS232-TCPIP_e.p65 Page 0 Bergstr. 33 869 Diessen-Obermühlhausen Postfach 2 4 D-86908 Diessen Tel. 0896/93400

3 Connecting the RS232 - TCP/IP Converter to an existing cable If you already have got a REINHARDT weather station connected to the serial port of a PC, you may extend your installation with the RS232 - TCP/IP converter without the need to install new cables. To perform this you only need a REINHARDT standard power cable with wall adaptor 8VDC and RS232 connector for powering the RS232 - TCP/IP converter and an adaptor (2 x male 9-pole D-SUB connectors) to couple the serial plug of the existing cable and the power cable of the RS232 - TCP/IP converter. When installed the RS232 - TCP/IP converter the weather station now has got an IP-address for accessing via a network. 4 Connection schematics 4. Standard connection Below you see the standard connection of the TCP/IP converter indoor. Both the weather station and the TCP/IP converter are powered by the same PSU unit. Weather Station TCP/IP-Converter Indoor Router / Switch 9-pol. SUBD female (not used for normal operation) PSU 2m ready made cable with 7-pole Binder plug and PSU Patch-Cable 0m - 00m ready made : cable with 2 x 7-pole Binder plug RS232-TCPIP_e.p65 Page Fax: 0896/7005 E - Mail: wetter@reinhardt-testsystem.de Web: http://www.reinhardt-wetterstationen.de

4.2 Afterwards connection to an existing weather station Below you see the recommended connection of the TCP/IP converter indoor to an existing weather station without the need to install a new cable to the weather station. The weather station and the TCP/IP converter are powered with their own PSU unit. The existing cable remains and the new cable (2m ready made cable) is used to power the TCP/ IP converter indoor. (left receptacle) The serial line of the weather station is connected to the serial input of the TCP/IP converter indoor via an additional adaptor (9-pole D-SUB male to 7-pole Binder) (right receptacle) The upper picture is obsolete, below the current connection schematic. RS232-TCPIP_e.p65 Page 2 Fax: 0896/7005 E - Mail: wetter@reinhardt-testsystem.de Web: http://www.reinhardt-wetterstationen.de

4.3 Connection with RS-422 port When your TCP/IP converter is eqipped with RS-422 port the connection is performed as shown below: Weather station TCP/IP-Converter Indoor with RS-422 Router / Switch RS-422- converter 2m cable with open Ends for connecting to a RS-422 converter with mains adaptor mains adaptor Patch-cable up to 000m RS-422 : cable with two 7-pole Binder connectors (Caution: with cables longer than 00m the supply voltage maybe needs to be increased to compensate the power loss on the cable! The internal jumpers have to be placed on the left side for RS232 and on the right side for RS422. RS232-TCPIP_e.p65 Page 3 Bergstr. 33 869 Diessen-Obermühlhausen Postfach 2 4 D-86908 Diessen Tel. 0896/93400

I&OE / Specifications subject to change without prior notice! 09/7 RS232-TCPIP_e.p65 Page 4 Fax: 0896/7005 E - Mail: wetter@reinhardt-testsystem.de Web: http://www.reinhardt-wetterstationen.de