DSC PowerSeries Neo Integration

Similar documents
DSC POWERSERIES NEO INTEGRATION. This application note will explain how to setup the DSC PowerSeries NEO integration on a KT-400 or a KT-1-M

DSC MAXSYS INTEGRATION THROUGH A KT-400 CONTROLLER

Release Notes. DN / Version 4.03

exacqvision DSC PowerSeries Neo integration

Connect Alarm app App operation quick guide

Exacq Mobile. User Manual 9.2. (Updated March 9, 2018)

Developer s Guide. PC54O1 Serial Interface Module Version 1.0

Exacq Mobile. User Manual. September 2018 Version 9.6

Pro-Watch 3.8 Eco System Galaxy Dimension Integration Guide

exacqvision Kantech - Client Integration Guide

Telephone and Reporting Setup in ElkRP

New Product Announcement

High Security and Access System EVO48 V2.1 EVO192 V2.1

Honeywell Total Connect enables notifications and control via the Web, , or Phone from a Remote Location

MG/SP Series (V4.9/V5.1) What s New

M2M Services. M2M Smartphone Application Overview v.2.0

Configuring Door and Device Templates

Understanding Door Configuration

Avantis AXI WEB SERVER MODULE USER MANUAL

TCS Access Control System Cheat Sheet

INT-TSI Brief User Manual

2015/09/24. M-Touch

FSK TX CELLULAR PLUS. Installation and Programming Guide. Tel:

SOFTWARE VERSION 3.20

Digiplex EVO High Security and Access System What s New EVO192 V2.7

Release Notes Access Control and Security Management Software

5.5 AS Layout. GeoVision Technical Handbook 77

Keypad LCD (software version 3.10) CA-10 plus

NOTE: This integration applies only to the Bentel Access Control Panel/Keypad equipment with firmware version 3.50 or later.

SOFTWARE VERSION 3.10

Total Connect 2.0 Online Help

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO D ISSUED NOVEMBER 2002 VERSION 2.

NetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup

pro ACTpro IOM INPUT/OUTPUT MODULE Installation and Configuration Instructions for the ACTpro IOM Input/Output Module ACT Product Code: ACTPRO IOM

Important Notice. Customer Information. 2 WisDom User Manual

XR500/XR100 Command Processor Review. a) Zone expanders c) Output expanders b) All of these d) Single point detectors

CONCEPT 3000/Access 4000 User Manual UK Supplement

User Guide. Connect2Go User Guide rev1.0 PO Box 3382 Station Main, Meaford Ontario N4L 1A5 T: (+1)

PROGRAMMING HELP GUIDE

NetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup

INT-RS module - short technical description

2 IDS LCD Keypad User Manual C Issued March 2009

Total Connect User Guide K /09 Rev. C

ACCESS CONTROL QUICK INSTALL GUIDE. tel: +44 (0) fax: +44 (0) web:

USER MANUAL. Disclaimer

M1 APPLICATION NOTE. Access Control Interface to Ness IP Access Control Systems (i.e. Edge, V2000 and V1000 Controllers)

PROGRAMMING AND INSTALLATION MANUAL

EVOHD. Programming Guide. Version

TouchOne Mini User s Guide

Keypad LCD-L (software version 3.10) CA-10 plus

Synergis Master Controller 2.2 Integration Guide for Axis Interface Modules

New Product Announcement

IDS X-Series User Manual E Issued June 2013

WebStation User Manual

Bosch Intrusion Panel Integration Guide

Stay connected to your home or business. Connect remotely from anywhere in the world.

S P E C I A L E D I T I O N E N T R A P A S S TM

Wireless Alarm System User Guide

EntraPass WebStation. User Manual DN

User manual. Misterhouse

Envisalink4/Honeywell Vista Installation and Programming Guide

Modules Programming Guide

Contents. 4. Disarming the Control Panel How to Disarm with a User Code How to Disarm using a Key-Switch or Remote...

Access Easy Controller 2.1 APC-AEC21-UPS1. Software Manual

New Product Announcement EntraPass v7.10 Software

Technical documentation

Access Control and Security Management Software Release Notes

Installer Notes 4110DL/XM, Vista 10, Vista-20, Via-30PSE

Update: Protection One OnLine Access now also offers the ability to make changes or additions to contacts on your account.

Integration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. Model Number(s): MAXSYS Series

Bosch solution 6000 cheat sheets

TM50 Touch Intuitive Touchscreen

PROGRAMMING. Alarm Control Panel. SATEL sp. z o.o. ul. Budowlanych Gdańsk POLAND tel Firmware Version 1.

Installation Guide. ZKAccess CLASSIC 3.5. www. zkaccess.com

Lab 5: Access Control Training Station

Applicable to the EURO 46, 76, 162 and 280 control panels, software V9 or above.

INT-GSM. GPRS communication module. Firmware version 1.00 int-gsm_en 07/18

SK-NET. Version 2. Installation and Operating Manual

PR402 v1.0 SINGLE DOOR ACCESS CONTROLLER

SILENCING AN ALARM. When the alarm bell or siren is sounding, enter your user code or present your keyfob to your keypad.

ACCO SOFT. Configuration program for ACCO NET access control system. User Manual

to that area and whether or not the Cardax FT GBUS URI (Standard or person holds these competencies. Wiegand variant)

Series. NX-8-EUR Control Panel. Installation manual

Safecom Solution-16 Quick Reference Guide ISSUE 1.10

Antipassback, Parking and Access Areas. Technical Support Engineering Rosslare Security NA For more information please see

XT30/XT50 OVERVIEW. Slide 1. Slide 2. Slide 3. Objectives. XT30/XT50 Basic Training System Overview. XT30/XT50 Description

G L O B A L E D I T I O N E N T R A P A S S TM

C O R P O R A T E E D I T I O N E N T R A P A S S TM

C24 Installation and Activation

EC-11 Ethernet Converter

Colour Graphic Terminal User Manual. Rev 3.1

VISTA-20SEa. 3-Partition Security System. Programming Form. V20SEaPRV1 9/98

New Product Announcement EntraPass v7.10/7.11 Software

ACTsmart2 Product Range Operating and Installation Instructions

Modules Programming Guide. paradox.com

LCD User Station User Manual

USER GUIDE. for ios Version 1. alula.net ALULA 1

4.2. LockView N. Instruction Man

Wednesday, October 07, WebBrix. Admin Guide

LIFT CONTROL WITH FLOOR BUTTON FEEDBACK (V3 OR LATER)

Transcription:

DN2120-1015 DSC PowerSeries Neo Integration The purpose of this application note is to explain how to setup the DSC PowerSeries Neo integration with a KT-400 or a KT-1-M (or PCB) using an RS-232 or IP connection. Minimum Requirements: EntraPass Special, Corporate, or Global Edition 6.04 or higher. Kantech Controller: o KT-400 Firmware 1.17 or higher o KT-400 rev1 Firmware 1.23 or higher o KT-1-M or PCB Firmware 1.03 or higher DSC: o Neo alarm Panel Firmware 1.10 Verify Firmware at menu [900]-[000] o TL280R or TL2803GR(E) or 3G2080R(E) Firmware 5.00 Verify Firmware at menu [900]-[460] o Neo HS2LCD Keypad Firmware 1.10 Verify Firmware at menu [900]-[001] Connection 1

Neo Configuration: Using the DSC PowerSeries Neo Keypad: 1. Enable the TL280R, TL2803GR(E), 3G2080R(E) settings: a. [*8]-[installer code]-[382], Communicator Option 3, set option {5} ON 2. Enable SMS unicode a. Section [851][301] Option 5 SMS Unicode needs to be ON. 3. Enable communication: a. RS-232: [*8]-[installer code]-[851]-[425] > Ensure only bits 1 and 5 are ON b. IP: [*8]-[installer code]-[851]-[425] > bit 3 and 5 [*8]-[installer code]-[851]-[428] > define the panel IP address UDP: [*8]-[installer code]-[851]-[426] > bit 1, 3, 4 TCP: [*8]-[installer code]-[851]-[426] > bit 3 4. Enter Integration Identification Number in EntraPass a. [*8]-[installer code]-[851]-[422] Capture all 12 hex values and enter in EntraPass (only the first 6 digits will be visible, use the arrow keys to see the remaining digits) 5. Enter Integration Access Code in EntraPass a. [*8]-[installer code]-[851]-[423] Capture all 8 hex values and enter in EntraPass (only the first 4 digits will be visible, use the arrow keys to see the remaining digits) EntraPass Setup: If virtual zone is to be used, please program virtual zone. Address 560, please refer to PowerSeries Neo programming manual. Go to the Devices tab and select the Integrated Panel button a. Click the New button and name the device accordingly b. In the Connection Type drop down list, select DSC PowerSeries Neo connected to controller (Serial or IP) or DSC PowerSeries Neo connected 2

to gateway (Serial or IP) c. In the Panel model drop down list, select the Panel model d. Click the Configuration button and enter the master code in the Master code textbox Note: This code will be used for receiving the programming and updating the alarm panel with the new user codes. The default Master code in a DSC intrusion panel is 1234. e. In the Controller selection for pass-through select the controller is connected to DSC PowerSeries Neo panel 1. Enter the Integration Identification Number and Integration Access Code gathered in the Neo Configuration section 3

f. Under the communication tab, Select if the integration to the communicator will be done via RS-232 / IP-TCP or IP-UDP. For IP, enter the information obtained by the NEO configuration. 1. Using TCP, the IP address of the controller is automatically entered. Within the NEO configuration, will need to enter this IP address. g. Click Ok h. In the Panel Component tab, select the number of zones, partitions and users to be included i. Click Save j. The Configuration Form will reappear. Select the Default Code and click OK. Note: The uploading of the intrusion panel may take 2-3 minutes depending on the programming. During this time, the intrusion panel will be in programming mode. Once the 4

intrusion panel uploading is complete, an event called Panel components upload completed will occur in the message list. Programming user codes: To program new user codes or to modify existing ones, go to the Devices tab and select Integrated Component a. Within the Integrated component tab, make sure the View component hierarchy button is pressed b. To better manage the components, click the All Components button and select Users c. Select the Corporate gateway that the intrusion panel is connected to under the Gateway drop down list d. From the Panel drop down list, select the previously created intrusion panel e. From the Component drop down list, select a user, and name the user accordingly f. Click on Configuration g. Enter the user access code that will be used h. Save the configuration Note: there is an icon in the Component type list box. This icon represents the status of the component. 5

Note: The EntraPass system can only download information from the intrusion panel while it is disarmed. If the intrusion panel is armed, EntraPass will buffer the modification until the intrusion panel disarms. Arming and disarming via manual operations: To request an arming or disarming of partitions, go to the Operation tab and select Integrated panel a. If shown, on the left pane select the proper intrusion panel b. In the right pane, select the partition you wish to arm or disarm c. Right click on the partition and select a task 6

Intrusion on Graphics: To view a virtual keypad or intrusion components from a graphic, go to the Definition tab and select the Graphic button a. Create a new graphic or choose the appropriate graphic from the Graphic drop down list b. Click the Click here to create, edit or modify a graphic button c. Drag and drop the Panel component icon on the graphic screen d. Select the Keypad from the list box Note: You may also add zones and partitions on the graphic. You may arm and disarm partitions by setting default double click functions. e. Close the window by clicking on the at the top f. Save the graphic g. You may view a graphic from the graphic desktop Viewing events and reports: 1. To view intrusion events, go to the Desktop tab and select Desktop 1 Button. a. From the Message list, you can view all the access and intrusion events. b. To view only access or intrusion events, click on the All Events button and select DSC intrusion events 7

2. You may generate reports, video trigger, real time email notifications and alarm acknowledgments based on intrusion events. You can better search for events by sorting by access control events or intrusion events in the above mentioned windows. Single Partition Management (by partition) via a Reader: To arm a single partition via a reader, go to the Devices tab and click the Door button a. Make the appropriate Gateway, Site and Controller selections, and select the door used for arming/disarming the partition b. Go to the Options and alarm system tab and click the External alarm system options button c. In the Alarm system options window: i. For arming: 1) If you are arming via card and pushing button, choose the appropriate input in the Arming request Input 2) If you are arming via card and keypad button, choose the appropriate button to be used as an arming request in the keypad button drop down list ii. iii. Choose when cardholders will be able to arm the intrusion system by choosing a schedule in the Enable Arming Request schedule textbox Choose which card holder will be able to arm the intrusion system by choosing a single access level, or group of access levels, in the Arming access level textbox iv. Go to the Disarming request tab and choose which card holder will be able to disarm the intrusion system, by choosing a single access level or group of access levels in Postpone or disarm access level textbox 8

v. Go to the Partitions tab and under the Partition to arm textbox select the partition associated to this door. vi. Check the Authorize disarming during exit delay if you want to be able to disarm during an exit delay vii. Press Ok and save the door. Note: The default user code programmed earlier in step 2.f is used as the user code for arming and disarming of the partitions. PLEASE NOTE: THERE IS NO VIRTUAL KEYPAD WITH THE NEO INTEGRATION. 9

Virtual Zones Programming (Single Panel): DSC PowerSeries Neo allows the assignment of up to 32 of its total zones as virtual zones. A DSC PowerSeries Neo zone can be triggered in Alarm, Trouble, Tamper by Kantech inputs, doors or controller events using Virtual zones. The benefit is that a Kantech Controller Door can cause an event on a DSC PowerSeries Neo zone without any wiring, and transmit the event to the monitoring central station if needed. Note - the following Firmware is required: o KT-400 Firmware 1.17 or higher o KT-400 rev1 Firmware 1.23 or higher o KT-1-M or PCB Firmware 1.03 or higher Note: HS2016 can only have 16 virtual zones The following steps describe the method to program a single panel as a virtual zone: 1. DSC Virtual zones need to be assigned to a DSC physical zone using the DSC keypad using option a. On the keypad: [*8]-[installer Code],[560] b. Scroll the Virtual Zone desired and press * c. Choose the physical zone to be linked: ex: 009 d. Press # when done 2. Go to the Devices tab and select the Integrated Panel button a. Select the previously created DSC PowerSeries Neo panel b. Click the Panel Component tab c. Under Virtual zone select the number of virtual zones you have d. Save the integration module 3. Go to the Devices tab and select the Integrated Component button. a. Select the appropriate Virtual Zone in the Component dropdown list b. Click on Configuration c. Choose the Kantech component type to link in the Component type dropdown list d. Choose the Kantech component in the Component source 10

e. Check the proper DSC Component action the Virtual zone will cause on the DSC PowerSeries Neo f. Press Ok g. Save the virtual zone Virtual Zones Programming (Multiple Panels): The following describes the method to program a multiple panels as virtual zones using the virtual zone mapping window: In order to link components from multiple controllers, the gateway will manage or supervise the events of all controllers, other than the one where the Neo panel is used. The virtual zone mapping window will now be populated with all appropriate devices. When opening the mapping of components to a virtual zone, the list of components is based on the devices of the same gateway and same account where the Neo panel is used. For example, doors: the doors will be listed where Neo is connected, along with and doors of all the other controllers using the same gateway. 11

The Gateway will monitor the events from the other controllers and send commands to the KT s DLL to update the virtual zone, accordingly. Communication With NEO Panel RS-232 IP / 485 KT-1 KT-1 / KT-400 Neo passthrough IP / 485 Update KT DLL Command to Neo Panel IP State of components are reported to the gateway based on the normal process. Integration DLL at the gateway level process link between EntraPass Controller- Door-Input and, if required, send command to the KT/NEO interface to change the steate of the virtual input on the NEO panel. IP / 485 Slave Controller Gateway IP / 485 KT-300 slave controller IP Server Using this connectivity, where the gateway is sending commands to Neo (through a KT-1 or KT-400), it is possible to interact with all types of controllers on that gateway (KT-100, KT- 200, KT-300), even if connected through RS-485 bus. 12

Input Door Events EntraPass Events to DSC Virtual Zones status: Input in Alarm EntraPass EntraPass Events Input in Trouble (only Double EOL) Input tamper in alarm (only Double EOL) Open/Close (Door contact status) Door forced open Door alarm on relock Door pre-alarm open too long DSC PowerSeries Neo REPORT ALARM REPORT TROUBLE Door open too long Door lock device failure Duress Duress Feature (Timed Reset) Controllers Controller AC power failed / Controller AC power restored REPORT TAMPER Controllers Tamper switch in alarm / Tamper switch restored Controller Auxiliary power failure / Controller Auxiliary Controllers power restored Controllers Controller reader power failure / Controller reader power restored Controllers Controller battery power failure / Controller battery power restored Controllers Controller module communication failure /Controller module communication restore Controllers Controller DC power failed / Controller DC power restored Controller lock power failed / Controller lock power Controllers restored Controllers Controller power trouble (KT-1) Door Door forced open / Door forced open Restored Door Door open too long / Door open too long restore Door Door lock device failure / door lock device failure restored Access Denied Access Denied Bad Card Status (Timed Reset) 13

The PowerSeries Neo/Kantech integration provides users with the following abilities: Receiving programming of the intrusion system: the partition and zone names can be uploaded to the EntraPass software from the intrusion panel. The partitions and zones can be used for various actions, such as operator operations. Additionally, the user codes can be uploaded from the intrusion panel and stored in the EntraPass software. The EntraPass operator can program and download new user codes to the intrusion panel or modify existing ones. Receiving events from the intrusion panel: the intrusion panel events can be viewed on the message list, and be used for reporting in conjunction with the standard access events. Furthermore, these intrusion events can be used to trigger video recordings, pop-up alarms, email notifications and other actions. Manual operations from EntraPass: the operator can perform manual operations on partitions from the EntraPass software, operations such as: Partition arm away, partition arm stay, partition arm no entry delay, partition arm with code, and disarm partition with code. Using intrusion components on graphics: the uploaded zones and partitions can be used in graphic floor plans to visualize where each zone, partitions and traditional access control components, are located on the floor plan. The operator can view the status of each of the components and perform operations on partitions. Arm and disarm partitions: the intrusion panel partition can be linked to a reader or readers to request an arming and disarming of the partition via a card. When a card holder presents a card and pushes the appropriate button on the reader, the KT- 400/KT-1 will send an arming request to the intrusion panel. When a card holder presents a card and opens the doors, the KT controller will send a disarming request to the intrusion panel. The EntraPass software supports single partition management per reader or multiple partition management per reader. There is no support for Virtual Keypad at this point with this integration. 14