Basic Drive Programming PowerFlex 755 Basic Start Up

Similar documents
L18 - PowerFlex Drives Configuration & Programming. For Classroom Use Only!

L09 - Drive Configuration & Programming Lab. For Classroom Use Only!

For Classroom Use Only! Flying Start PowerFlex 755 AC Drives

Bus Regulation. PowerFlex 755 AC Drives. For Classroom Use Only!

1336-Series Drives to PowerFlex 750-Series Drives

FlexPak 3000 Drive Operator Interface Module (OIM) User s Guide

1336 PLUS II Quick Start Guide

Using the 20-HIM-A6 HIM with the LiquiFlo 2.0 AC Drive 20-HIM-A6 Firmware Revision Number or Later

GV3000/SE AC Drive Quick Reference Version 6.06

GV3000/SE 230 VAC 1-20 HP General Purpose (Volts/Hertz) and Vector Duty Drive Software Start-Up and Reference Manual Version 6.04

Quick Start. PowerFlex 750-Series AC Drives

GV3000/SE Operator Interface Module (OIM) User Guide Version 2.0 M/N 2RK3000

Firmware Manual - EC Series Drives

Drive Application Software Application Set

Adjustable Frequency AC Drive

Bosch Rexroth EFC3610 Frequency Inverter. Easy Start Guide L1 L2 L3 (+) B U V W

Quick Start Guide For GVX9000 AF Drives

QUICK REFERENCE GUIDE

Optidrive VTC Modbus RTU Register Map

Unidrive M200, M201 (Frame 1 to 4) Quick Start Guide

PowerFlex 700H Adjustable Frequency AC Drive. Programming Manual V1.xxx 5.002

Power Connections: Basic Wiring:

E2 Modbus RTU Register Map

Optidrive Applications Support Library

SJ300 Closed loop vector control (Velocity)

E2 Modbus RTU Register Map Revision History Version Comments Author Date 1.02 Previous version PAE 11/06/ Revised to new format PAE 09/03/09

LS M100 Frequency Inverter Easy Start Guide

Quick Start Guide Cutler-Hammer SVX9000 Drives from Eaton Corporation CONTENT STEP 1 Keypad Operation Overview STEP 2 Standard Wiring Diagrams and

PowerFlex 755 Drives (revision 4.002)

Orientation F7 Drive Software Technical Manual

PowerFlex 70 Adjustable Frequency AC Drives

PowerFlex 700H Drive Firmware (Revision )

LiquiFlo AC General Purpose (Volts/Hertz) and Vector Duty Drive Software Start-Up and Reference Manual Version 6.4

GV3000/SE General Purpose (Volts/Hertz) and Vector Duty AC Drive, HP, 230V AC

DRIVE STARTUP MANUAL Magnetek HPV900-S2 Drive

PowerFlex 753 Drives (revision 8.002)

Unidrive M400 (Frame 1 to 4) Quick Start Guide

Optidrive Applications Support Library

EQ5 SERIES Quick Start Guide for Constant Torque Applications

Variable Frequency Drive Design Guidelines

Mitsubishi D700-SC Frequency Inverter. Easy Start Guide. The Mitsubishi D700-SC Frequency Inverter range is available to order from inverterdrive.

TECO L510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

LiquiFlo 1.5 AC General Purpose (Volts/Hertz) and Vector Duty Drive Software Start-Up and Reference Manual Version 1.2

PowerFlex 700H Sample Specification

890 Quickstart Manual

Distributed Power System SA3100 Drive Configuration and Programming

SJ300 Closed loop vector control (Electronic Gearing)

PowerFlex 753 Drives (revision )

PowerFlex 700 Drive w/vector Control Option (Revision 9.001)

Flexible, simple, economical, robust.

INSTALLATION AND OPERATION MANUAL KBDF SERIES

USER GUIDE. Tolomatic Motion Interface (TMI) Actuator Control Solutions for: ACS Stepper Drive/Controller Tolomatic Electric Linear Actuators

GPD515/G5 Software Option (VSG114701) Part Number: CIMR-G5MXXXXXF-017 (1) (1) ZZZZ refers to the base Model Number

Vacon HVAC100 Commissioning Guide

PowerFlex 700 Sample Specification Vector Control (Series B)

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Advanced User Guide Revision 2.00

PowerFlex 700 Sample Specification Vector Control (Series B)

G7/H7 Applications Workbook

3GV M Modbus RTU Register Map

CS3000 MMI SW-Version 6.1 Control and Configuration Software for FlexPak3000 V , GV3000 V and Liqui-Flo. Instruction Manual

ETM MD100 Drive System 1/2HP (370W) User Manual. Table of Contents. Drive Features

Status line The top line of the LCD display shows the basic status information of the drive.

CX-1200 STARTUP GUIDE

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

Section 16. Drives AF-650GP General Purpose Drive. Standard Specifications. Environmental Conditions. Logic Controller (LC) Sequencer

ELECTRICAL & COMPUTER ENGINEERING TECHNOLOGY. The Compact Logix PLC will be utilized to control the operation of the PowerFlex-40 VFD.

PowerFlex 4-Class of AC Drives

ControlMaster. Crane Inverter Control Systems. Innovation... Performance... Reliability.

Position Control via HMI Connected Components Building Block. Quick Start

PowerFlex 755 Drives (revision )

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

Reliance GV3000 Drive Registers

M4000 SERIES DIGITAL 3PHASE DC Drives HP

SV9000 AF DRIVES SVReady User Manual. Pump and Fan Control Application

P9 ASD Simple Start Guide

Technical Instructions Document No February 25, Modbus RTU Interface Module for SED2. Description. Product Part Number

Quick Start Guide RSi S Series VFD. Using the 7-segment (4 digit LED) Keypad/Display

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Advanced User Guide Issue 06

PowerFlex 753 Drives (revision 9.002)

Parameter Reference Guide. KBG2 Series. RFC-A Mode

SED2 Variable Frequency Drives

USER GUIDE. Tolomatic Motion Interface (TMI) Actuator Control Solutions for: ACS Stepper Drive/Controller Tolomatic Electric Linear Actuators

Optidrive Plus 3 GV. Advanced User Guide. Vertical Market Solution : Industrial Washing Machines. Revision 1.00

Powered to Perform. Everyday Reliability. Exceptional Value. Expertise and Support

890 Quickstart Manual 890CS/CD (Common Bus) Drives Frames B, C & D

AF-60 LP TM Micro Drive. Programming Guide

Safety Instructions 1-1 Avoid unintended Start General Description 2-2

PRODUCT PROFILE. PowerFlex 700 AC Drive. Powerful Performance. Flexible Control. Excellent Performance

Metasys N2 Instruction Manual VLT Adjustable Frequency Drive. 12/ Revision B

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

1. PRODUCT OVERVIEW GENERAL INFORMATION STANDARDS & EMC ELECTRICAL RATINGS MECHANICAL INSTALLATION...

PowerFlex 20-HIM-A6 and 20-HIM-C6S HIM Firmware Revision 1.006

PowerFlexDC & 20-COMM-P Adapter with Siemens S7-315DP PLC

Basic control panel. Features. Control panels 75

DV-300 DC DRIVE. DV-300 DC Drive

GPD 506/P5 Apogee - FLN Technical Manual

AC Tech. Variable Speed AC Motor Drives. SCN Series Installation and Operation Manual

160 SSC Variable Speed Drive to PowerFlex 4/4M/40 Drives. Conversion Guide

E510. Compact Drive IP 20/ NEMA HP (230V) 1-75 HP (460V)

890 Quickstart Manual

Transcription:

Basic Drive Programming PowerFlex 755 Basic Start Up

PowerFlex 755 Basic Start Up for Speed Controlled Applications Contents Before you begin... 4 Tools... 4 About this lab... 4 About the Demo... 4 Lab Setup... 5 Lab Objective... 9 Using the Human Interface Module (H.I.M)... 10 Assisted Startup using the Human Interface Module (H.I.M)... 11 Resetting factory defaults... 12 Setting the Motor Control Mode... 15 Entering Motor Nameplate Data... 16 Setting the Speed Feedback Device... 20 Setting the Speed Limits... 22 Direction Auto Tune and Inertia Tests... 23 Configuring the Speed Reference and Ramp rates... 28 Configuring the Inputs and Outputs... 29 3 of 31

Before you begin Tools Windows XP PC with DriveExplorer or Drive Executive PowerFlex 755 Training Demo About this lab This session provides you with an opportunity to explore the PowerFlex 755 AC drive. In this session you will learn to: Use the Assisted Startup for simple Speed Controlled Applications Control the Drive and spin a Motor This lab takes approximately 50 minutes to complete. About the Demo The image below labels the switches, push buttons and the potentiometer required in this lab session. DRIVE POWER IN 0 IN 1 IN 2 0-10 VDC IN 0 24 VDC CONTROL POWER 4 of 31

Lab Setup 1. Verify that the selector switches labeled Drive Power and 24VDC Control Power is in the ON position. 2. Make sure all the Selector switches (IN 2, IN 3, IN 4, and IN 5) are in the left (OFF) position. 3. You may need to consult an instructor for help, to complete this step. If the Safe Speed Monitoring module is installed and enabled in the PowerFlex 755 demo (typically slot 4), the safety mode needs to be disabled prior to conducting the lab. If the safety mode has not been disabled, the drive will not operate according to the lab procedure. To do this complete the following steps: a. Use Drive Explorer or Drive Executive to connect to the drive. b. Navigate to the Safe Speed Monitoring module parameters via the Drive Explorer, or Drive Executive. (Drive Executive shown) 5 of 31

c. Set parameter #6 - Operating Mode to Program. (Drive Executive shown) d. Next, set parameter #21 Safety Mode to Disabled. (Drive Executive shown) 6 of 31

e. Finally, set parameter #6 Operating Mode to Run. (Drive Executive shown) 4. You may need to consult an instructor for help, to complete this step.if a DeviceLogix Program is loaded and running in the PowerFlex 755 demo, the DeviceLogix logic needs to be disabled and the drive reset prior to conducting the lab. If the DeviceLogix program has not been properly disabled, the drive will not operate according to the lab procedure. a. Use Drive Executive or DriveExplorer to connect to the drive. These steps can also be completed using the HIM. b. Navigate to the DeviceLogix >>> Status & Control parameters using Drive Executive. (Drive Executive shown) 7 of 31

c. Set parameter #53 DLX Operation to DisableLogic. (Drive Executive shown) d. Next, highlight 0 PowerFlex 755, right-click and select Reset Drive (Drive Executive shown) (For the HIM select Port 0, select DIAGNOSTIC folder >>> Reset Device) 8 of 31

e. Finally, click OK to reset the drive. Communications will be lost at this time. (Drive Executive shown) (For the HIM when prompted to confirm reset device, click ENTER.) Lab Objective At the end of this lab, you should have successfully completed the Assisted Startup routine of the PF 755 drive and 1. Programmed the Drive to start the drive/motor using the green pushbutton labeled IN 1. 2. Programmed the Drive to stop the drive/motor using the red pushbutton labeled IN 0. 3. Programmed the Drive to forward or reverse the drive/motor using the selector switch labeled IN 2. 4. Programmed the Drive to get Speed Reference from an Analog Source, the potentiometer labeled 0-10 VDC IN 0. 9 of 31

Using the Human Interface Module (H.I.M) The image below shows some of the essential keys which you will be using in this session. Please familiarize yourself with these keys (buttons) Soft Keys Navigation Keys Enter Key Stop Key Start Key Folders Key 10 of 31

Assisted Startup using the Human Interface Module (H.I.M) One of the ways to perform an Assisted Startup on the PowerFlex 755 is using the Startup routine in the H.I.M. The following steps will lead you through that: 1. Access the Status screen which is displayed on HIM PowerUp. PowerFlex 755 240V 4.2A 20G... B4P2 2. Press the Folders button on the HIM keypad. The button is located on the bottom row of the HIM Keypad (shown circled in the left image below).pressing the Folders button changes the HIM screen display to the Folders screen ( see right image below) 11 of 31

Resetting factory defaults 3. Use the left or right arrow keys to scroll through the different folders, to locate the folder called MEMORY. 4. Use the down arrow key to highlight Set Defaults if necessary and press the Enter key located in the center of the HIM keypad to make this your selection. 5. The screen which follows after completion of the previous step is shown. Use the down arrow key to highlight This Port only. Press the Enter key keypad to make this your selection. located in the center of the HIM 12 of 31

6. Use the soft key labeled ALL to reset default all parameter settings in the Drive. 7. Use the CLR soft key to acknowledge and clear the Module Defaulted fault. 8. Press the Folders button on the HIM keypad again to access the Folders Menu. 9. Now use the left or right arrow keys to scroll through the different folders, to locate the folder called START UP. 10. The first item listed in the START UP folder is Begin Start Up and this is highlighted by default. Press the Enter key located in the center of the HIM keypad to make this your selection. 13 of 31

11. The startup routine starts with an Introduction screen. Press the ENTER soft key to continue. The ENTER soft key is located on the top row of the HIM keypad. Note: You can always use the ESC soft key to return to a previous step. 12. Pressing the ENTER soft key in the previous step has led you to a new screen, which allows you to select the type of startup you wish to perform. For this lab session, we will choose General Startup. This is highlighted by default. Press the ENTER soft key located on the top row of the HIM keypad to make this your selection. 14 of 31

Setting the Motor Control Mode 13. Pressing the ENTER soft key in the previous step has led you to the General Startup Main Menu. You will go through steps listed in this menu to configure your drive. Press ENTER soft key to enter the first section Motor Control. 14. The introduction screen provides information about the Motor Control section. Press the ENTER soft key to continue. 15 of 31

15. Pressing the ENTER soft key in the previous step leads you to a screen which lists the available motor control modes in the PowerFlex 755. For this lab session, we will choose the Flux Vector mode. Use the scroll down or scroll up arrow soft keys to select Flux Vector. Press the ENTER soft key to make this your selection. Startup Motor Control Please Select: Sensorless Vect V/Hz Flux Vector ABORT ENTER 16. Pressing the ENTER soft key in the previous step leads you to a screen which lists the available Motor Types in the PowerFlex 755. For this lab session, we will choose the default selection of Induction. Press the ENTER soft key to make this your selection. 17. Pressing the ENTER soft key in the previous step leads you to a screen which lists the available Motor Control Modes in the PowerFlex 755. For this lab session, we will choose the default selection of Speed. Press the ENTER soft key to make this your selection Entering Motor Nameplate Data 18. After selecting the motor control mode in the previous step, you are directed back to the General Startup Main Menu. Motor Data should be highlighted now. Press the ENTER soft key to make this your selection. The next few steps will require you to input the nameplate information of the motor you are doing a Startup on. 16 of 31

19. Pressing the ENTER soft key in the previous step has led you to the Startup Motor Data Entry screen. The first information you will provide is the Motor Nameplate (NP) Volts. The Motor in the demo is rated for 230 V. This should be the default value for this parameter. Press the ENTER soft key to confirm your input and move to the next screen. 20. The next information you need to provide is the Power Units. By default the value of the parameter should be set to HP. Press the ENTER soft key to confirm your selection and move to the next screen. 17 of 31

21. You will now be required to input the Motor Nameplate (NP) Power. The motor internal to the demo is rated 25 Watts (0.025 kw) or 0.033 HP. Notice that there are no designated buttons on the HIM keypad for entering a decimal point. The PowerFlex 755 HIM keypad uses a soft key to provide a decimal point button. This decimal point soft key is activated when the first digit in the numeric value is entered. In this case, start by entering 0. Notice how one of the soft keys (top row of the HIM keypad) is now a decimal point button. Use the decimal point soft key button and the appropriate number keys to input a value of 0.033. Press the ENTER soft key to confirm your input and move to the next screen. 22. You will now be required to input the Motor Nameplate (NP) Amperes. The Motor in the demo is rated for 0.22 amps. Use the decimal point soft key button and the appropriate number keys to input a value of 0.22. Press the ENTER soft key to confirm your input and move to the next screen. Startup Motor Data Entry Edit Motor NP Amps Def 2.90 0. 22 Amps EXP Min Max 0.00 42.00 23. You should be in the Edit Motor NP Hertz screen. The Motor in the demo is rated for 60 Hz. The Default value should be 60 Hz. Press the ENTER soft key to confirm your input and move to the next screen. 24. You will now be required to input the Motor Nameplate (NP) RPM. The Motor in the demo is rated for 1600 RPM. Use the appropriate number keys to input a value of 1600.Press the ENTER soft key to confirm your input and move to the next screen. 18 of 31

25. You should now be in the Edit Mtr OL Factor screen. This screen allows you to enter the Motor Overload factor. By default this parameter value is set to a value of 1.00. We will use this as our selection for this lab session. Press the ENTER soft key to confirm this and move to the next screen. 26. You should be in the Edit Motor Poles screen. The Motor in the demo is a 4 Pole motor. By default, this parameter value is set to a value of 4. Press the ENTER soft key to confirm this as your selection and move to the next screen. 27. You will now be required to input the Speed Units. For this lab we will use RPM for our Speed Units. Use the scroll down or scroll up arrow soft keys to select RPM. After this setting has been selected, press the ENTER soft key to confirm this and move to the next screen. 19 of 31

Setting the Speed Feedback Device 28. With the completion of the previous step, you have finished inputting the Motor Nameplate data and other information required in the Motor Data section. Pressing the ENTER soft key in the previous step has directed you to the Main Menu and the item Feedback should be highlighted. Press the ENTER soft key to make this your selection. 29. You should now be in the Speed Feedback Select screen. You will use the down arrow key to highlight Feedback. Once the list item Feedback is highlighted, Press the ENTER soft key to make this your selection and move to the next screen. 20 of 31

30. Pressing the ENTER soft key in the previous step has led you to the Speed Feedback Device Selection screen. You will be indicating your primary Speed (Velocity) feedback device in this step. For this lab session we will use the Dual encoder in port 6.Use the down arrow key to navigate and highlight Port 6 Dual Encoder. Press the Enter key key or the Enter soft key to make this your selection. 31. Pressing the ENTER soft key in the previous step has led you to the Select Param to Use screen. For this lab session we will select Encoder 0 Fdbk. Encoder 0 Fdbk should be highlighted by default. Press the Enter key to make this your selection. 32. The next screen allows you to configure the PPR on the Encoder you selected. The dual encoder you selected in a previous step is rated 3000 PPR. Use the appropriate number keys on the HIM keypad to input the numeric value 3000. Press the ENTER soft key to confirm this selection. 33. The Encoder Interface screen allows you to configure the chosen Encoder. Select the default highlighted option of Quadrature using the ENTER soft key. 34. Select Differential using the ENTER soft key to continue configuring the Encoder interface. 21 of 31

35. Select No using the ENTER soft key when asked the question Monitor marker pulse to detect loss of signal? Setting the Speed Limits 36. The previous step was the last step in configuring your feedback device. You should now have been directed back to the General Startup Main Menu. Configuring the limits is the next step in the Startup routine. Press the ENTER soft key to access Limits section. 37. For this lab session, we will be making the following changes in the Limits section. Use the number keys to input the values listed for each item and press the ENTER soft key to move forward to the next screen. After the four values have been entered, you will be exited out of this section. Max Fwd Speed = 1600 RPM Max Rev Speed = -1600.00 RPM (you can directly enter a value of 1600 ; the negative sign is defaulted) Min Fwd Speed = 0.00 RPM Min Rev Speed = 0.00 RPM 22 of 31

Direction Auto Tune and Inertia Tests 38. You should now have been directed back to the General Startup Main Menu. The Tests section is next and should be highlighted by default at this stage. Press the ENTER soft key to access Tests section. 39. There are two tests which are part of the Startup Routine. You will perform these tests in the next few steps. You will run the Direction test first. The Direction Test list item should be highlighted by default. Press the ENTER soft key to make this your selection. Press the Start key start the motor. to 40. The next screen asks the question Is the direction of rotation forward? To demonstrate the ability of the PowerFlex 755 to electronically swap motor leads to change motor direction, let us choose No as the answer to this question. Use the highlight No and press the Press the ENTER soft key. down arrow key to select and Startup Direction Test Is the direction of rotation forward? Yes No 23 of 31

41. The next screen asks the question How would you like to fix motor polarity?. Select the default highlighted option Automatic change by using the ENTER soft key. Startup Direction Test How would you like to fix the motor polarity? Automatic Change Change fbk wires 42. The screen that follows asks you to stop the drive so this change in direction, initiated in the previous step, can take place. Press the STOP key to stop the drive. 43. Follow the direction on the next screen which asks you to START the drive. You can start the drive and by using the START key. 44. The next screen asks the question Is the direction of rotation forward? and requires confirmation that the changes to direction are acceptable. Select Yes by pressing the ENTER soft key. 24 of 31

45. Since you made a change to the motor direction, the polarity of the feedback (encoder) has to be changed too. This screen will inform you about that. Press soft key ENTER to continue. 46. This screen asks the question How would you like to fix the feedback polarity? Select the default highlighted option Automatic change by using the ENTER soft key. Startup Direction Test How would you like to fix the feedback polarity? Automatic Change Change fbk wires 47. As required by the following screen, press the STOP key to stop the drive. 25 of 31

48. Press the START button to begin the test and review changed motor direction. 49. Select Yes as your answer when asked the question again Is the direction of rotation forward? Startup Direction Test Is the direction of rotation forward? Yes No 50. Press the Stop key.this should successfully complete the Direction test. 51. You should now be back in the Motor Test Menu screen. Now use the ENTER soft key to select the Auto tune Test. Read the important information on the screen and press the ENTER soft key. 52. Pressing the ENTER soft key in the previous step has directed you to the Select the tuning mode screen. For this lab session, we will perform a rotate tune on the demo motor. Select the default highlighted option Rotate Tune by pressing the ENTER soft key. 53. As directed by the HIM screen information, press the START key to start the Auto tune Test. Notice the changing information on the HIM (as the different parts of the Auto tune tests are completed).wait till the test is completed. 26 of 31

54. The completion of the test is indicated by the Test Completed Successfully screen. Press the ENTER soft key. 55. Select the Inertia Test using the ENTER soft key and use the ENTER soft key again to confirm that the load is connected to the motor. 56. As directed by the HIM screen information, press the START key to start the Inertia Test. 57. The completion of the test is indicated by the Test Completed Successfully screen. Press the ENTER soft key. This will bring up the Edit Speed Reg BW entry screen. Select the ENTER soft key to accept the default value of 10.00 R/S. 58. Pressing the ENTER key in the previous step has directed you back to the Motor Test Menu. Use the ENTER soft key to select Done in the Motor Test Menu screen. 27 of 31

Configuring the Speed Reference and Ramp rates 59. At this time you should be in the General Startup Main Menu. The next item on the Startup menu list Ref Ramp Stop should be highlighted by default. Press the ENTER soft key to make this your selection. 60. The Edit Direction Mode box should be on the screen now. We will use the default parameter value of Unipolar for this lab session. Press the ENTER soft key to confirm and save your selection. 61. You should be on the speed reference source selection screen. Use the down arrow or up arrow keys to highlight Analog Input as your Speed Reference source. Use the ENTER soft key to make this your selection. 62. In the window Select Port to Use that appears following the previous step, use the down arrow or up arrow keys to highlight Port 07 I/O module 24V. Use the Enter key to make this your selection. 63. Use the down arrow and up arrow keys, if necessary, to highlight Par 0050 Anlg In0 Value. Use the Enter key key to make this your selection. Press the ENTER soft key to confirm and save your selection. 64. The next few steps will configure the Analog Input you chose as Speed Reference. For this lab session we will use the 0-10V potentiometer (labeled 0-10VDC IN 0) on the demo as our Analog Input speed reference. Pressing the ENTER soft key in the previous step has led you to the first item required to configure the Analog Input. You should be in Edit Anlg In0 Hi screen. Press the ENTER soft key to accept the default value of 10.000 Volt. 65. In the Edit Anlg In0 Lo screen that follows, press the ENTER soft key to accept the default value of 0.000 Volt. 66. In the next few screens input these values Speed Ref A Anlg Hi = 1600 RPM and Speed Ref A Anlg Lo = 0 RPM. Press the ENTER soft key. 67. You should be in the Startup / Stop Config screen now, press the ENTER soft key to accept the default selection of Ramp to be used as Stop Stop Mode A. 68. Pressing the ENTER key in the previous step has directed you to the screen to configure the Bus Reg Mode A. Select the default of Adjust Freq using the ENTER soft key 69. Following the step to set bus regulation you will now set Ramp (Accel and Decel) times. In the Edit Accel Time 1 screen, use the appropriate number key to enter a value of 3 seconds. Press the ENTER soft key. 28 of 31

70. Similarly enter a value of 3 seconds for the deceleration time in the Edit Decel Time 1 screen. Press the ENTER soft key. 71. The next screen continues the ramp speed configuration and asks the question Do you want to perform S-curve for Accel/Decel?. We will select No as the answer for this lab session. You can select No by highlighting it using the down and up arrow keys and then using the ENTER soft key to confirm and save your selection. Configuring the Inputs and Outputs 72. Completing the previous step successfully has led you to the General Startup Main Menu with the item I/O highlighted. Press the ENTER soft key to enter the I/O section. 73. You should be in the Start Stop I/O screen now. The first item to configure on this list is Start Stop & Dir. Press the ENTER soft key to enter this section. Read the Introductory screen to this section and press the ENTER soft key to continue. 74. The next screen requires you to answer the question Will a Digital Input be used as a START Source? Select Yes using the down and up arrow keys and then using ENTER soft key to confirm and save your selection. We will use the green push button labeled IN 1 in the demo as our Start Source in a later step. 75. The next screen will ask the question Is Reverse required from a digital input?? Select Yes using the down and up arrow keys and then using ENTER soft key to confirm and save your selection. We will use the switch labeled IN 2 in the demo as forward/reverse in a later step. 76. Select 3 wire as your choice for the question Enter Choice for the control method. 77. In the Select Port To Use window use the up and down arrow keys to highlight Port 07 I/O Module 24V Press the ENTER soft key to make this your selection. 78. In the Param to Use window Press the Enter soft key to select 79. First, you will select the bit/digital Input you want to use as your START. We are going to use the green push button labeled IN 1 as our start input. To do this scroll to Bit 01 Input 1 and press the Enter soft key. 80. Follow procedures similar to the previous steps to select the red push button labeled IN 0 as your stop switch and the selector switch labeled IN 2 as your Forward/Reverse switch in that order. 29 of 31

81. You should now be back in the Start Stop I/O menu screen. This is all we will configure in this section so use the down arrow keys to scroll down to the last item on the list Done. After Done is highlighted, use the ENTER soft key to make this your selection. 82. You should now be back in the General Startup Main Menu screen.you have finished with the Startup routine steps required for this lab session. Select Done using the ENTER soft key to exit out this screen. 83. Select Exit Startup using the ENTER soft key to exit out of the Startup routine. 84. You can now test your drive to perform the functions you configured during the startup routine namely, Start using the green push button IN 1, Stop using the red push button IN 0, change direction using IN 2 and provide speed reference using the 0-10VDC IN 0 pot. 30 of 31

Notes 31 of 31