Transponder-coded. with guard locking

Similar documents
Versatile and safe. Transponder-coded safety systems CES

INDUSTRY. Ongoing dialog. Communication at Industry 4.0 level

Product Overview Safety Engineering electronic

More than safety. Product Overview. Safety Engineering

Safety light grids and light curtains LCA

Presentation. EUCHNER Multifunctional Gate Box MGB

Product Overview Safety Engineering electro-mechanical

Online data sheet. i110-e0453 i110 Lock SAFETY LOCKING DEVICES

Online data sheet. i10-e0454 Lock i10 Lock SAFETY LOCKING DEVICES

Connection of serial wired CTP-L1..-AR to Safety Relay ESM-BA..1

Online data sheet. i15-mm0123 Lock i15 Lock SAFETY LOCKING DEVICES

Non-Contact Safety System CES-AZ

Connection of serial wired MGB-L1..-AR to Safety Relay MSR127TP

Online data sheet. i10-m0233 Lock i10 Lock SAFETY LOCKING DEVICES

Connection of serial wired CES-AR to safety relay ESM-BA..1 Content

Safety System CES-FD. Non-contact safety system CES-FD- Direct connection to decentralized peripheral systems (e.g. ET200pro) PLC

System family AR. Transponder-coded safety switch CET.-AR- With guard locking

Online data sheet. i200-m0413 Lock i200 Lock SAFETY LOCKING DEVICES

Safety Switches with AS-Interface

Transponder-coded safety switches Interlocking devices and guard locking devices

Connection of CET3-AR to safety relay PNOZ X3.10P

Online data sheet. i200-m0323 Lock i200 Lock SAFETY LOCKING DEVICES

Connection of serial wired CTP-L1..-AR to Siemens ET 200S

Safety Switches CES-AR/CET-AR

Connection of MGB-L2..-AR to safety relay PNOZ s5

Connection of MGB-L2..-AR to safety relay PNOZ X3.10P

Connection of CES-AR to safety relay ESM-BA..1 Content

Connection of MGB-L1..-AR to Safety Relay ESM-BA..1

More than safety. Product Overview. ManMachine

Magnetically Coded Safety Switches CMS

The safe choice Selection of operation mode with EKS up to PL e

System family AP. Safety switch CET.-AP- With guard locking

Connection of CET3-AR to Pilz PDP67

Safety Switches CES-AR/CET-AR

SAFETY LOCKING DEVICES

Datasheet - AZM300Z-ST-1P2P-A

More than safety. System Manual Safety System MGB-AR in combination with a locking module MGB-L1-AR-.../MGB-L2-AR-...

Connection of CET3-AR to Pilz PDP67

MGB-L1B-EI on Allen Bradley ControlLogix with Gateway in Network

Product Overview ManMachine

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Compact Coded Magnetic Safety Interlock Switch and Control Units

Ordering details. Approval. Classification. Global Properties :27:33h. Solenoid interlock / AZM 161I / AZM 161I B6R

The Electronic-Key-System EKS

Online data sheet RE13-SAC RE1 NON-CONTACT SAFETY SWITCHES

Connection of CET4-AR to Siemens ET 200S

Non-Contact Safety System CES-AZ

The SMART Non-contact Safety Sensor SRF With an innovative diagnostic system

Connecting MGB-L1B-PN to Siemens S7 315F (TIA Portal V13)

Multifunctional Gate Box MGB

Available coding options

SMARTSCAN INFORMATION T4 SERIES LIGHT CURTAINS HANDBOOK

Interlock Switches. Selection Guide. HS7A-DMC Magnetic Safety Switches

Datasheet - MZM 100 B ST-1P2PW2REM-A

Product Overview Automation

Online data sheet. T40-E0101K T4000 Direct NON-CONTACT SAFETY SWITCHES

Transponder-coded safety systems with external evaluation

Connection of MGB-L1..-AR to Siemens ET 200S

Datasheet - MZM 100 B ST2-1P2PW2RE-A

EKS PROFINET Selection of Operating Mode with Pushbuttons

More than safety. Operating Instructions Non-Contact Safety Switch CES-AP-CR2-AH (Unicode) CES-AP-CL2-AH (Unicode)

Datasheet AZM 161 Z ST1 AS RA

SAFETY SWITCHES. Phone: Fax: Web: S20 Safety Switch

More than safety. Operating instructions Non-contact safety system CES-A-ABA-01/CES-A-ABA-01B (Unicode)

Versatile Safety Interlock Switch with Guard Door Locking

MGB. Multifunctional Gate Box MGB. How to find your

Safety. Detection. Control. MAGNUS RFID ENG - REV

Position detection with system The new compact position switches PS116

SAFETY COMMAND DEVICES

Safety Products Introduction LS-Titan Safety Interlock Switches. Technical Reference... 2

AOI for MGB-L1B-EI on Allen Bradley ControlLogix

Operating Instructions

Operating Instructions

Tongue Switches Trojan 5 & 6

Active face 57,5. Series Comment Version Order no. / item. Installation material 8-groove Bosch Installation material for CES-A-BSP

SERIES AZ15/16. Tamper-Resistant Movable Machine Guard Safety Interlock Switch. Features & Benefits. Description. Operation. Typical Applications

Datasheet - RSS 36-D-R-ST

Operating Instructions

Balluff smart safety BE ON THE SAFE SIDE. SAFETY OVER IO-LINK

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Operating Instructions

Non-contact Machine Safeguarding with RFID Technology. LED offers diagnostics for switch status, margin alignment, and fault finding

Safety switches for hinged doors

Non-Contact Safety System CMS. Magnetic Coding. More than safety.

Operating Instructions

Online data sheet STR1-SASM03P5 STR1 NON-CONTACT SAFETY SWITCHES

Online data sheet. IN30-E0407K IN3000 Direct NON-CONTACT SAFETY SWITCHES

24 VDC or 24 VAC/DC or 110 VAC or 220 VAC NOTE: 220 VAC not available for S2 and S3 configurations. EN1088, EN , EN292, EN

SERIES AZ15/16. Tamper-Resistant Movable Machine Guard Safety Interlock Switch. Features & Benefits. Description. Operation. Typical Applications

BERNSTEIN Contactless safety technology

AS-i Safety Relay Output Module with Diagnostic Slave

Safety Switches with AS-Interface

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

Safety switches with separate actuator

More than safety. Operating instructions Non-contact safety system CES-A-AEA-02B/CES-A-AEA-04B (Unicode)

Safety Systems Safety Integrated

Technical Data. General specifications. Rated operating distance s n 3 mm

PSR UC/ESAM4/3X1/1X2/B

Safety switches with manual mechanical delay and separate actuator

Online data sheet STR1-SAFM03P5 STR1 NON-CONTACT SAFETY SWITCHES

Transcription:

Transponder-coded safety switch CTP with guard locking

The safety switch CTP The new safety switch CTP combines the proven principle of operation of electromechanical safety switches with guard locking with modern transponder coded safety engineering. Thanks to the transponder technology, even a single CTP achieves category 4 / PL e according to EN ISO 3849- without additional fault exclusion and meets all the requirements of EN ISO 49. It is ideally suited to applications in which a high Performance Level and a locking force of up to 2500 N are required. Versatile in use The CTP reliably protects safety doors and fl aps on machines and mechanical equipment. Thanks to the integrated guard locking and guard lock monitoring it can be used for the protection of both processes and persons. The very compact design permits space-saving mounting on the safety guard. With a locking force of 2500 N the CTP eff ectively prevents the opening of safeguards. The very robust plastic housing with metal head as well as the high degree of protection IP 69K make the CTP the all-rounder for almost every industrial usage. The CTP is suitable even for harsh, dirty environments. Mounting and principle of operation The CTP comprises two components, a safety switch and an actuator. During mounting the safety switch is attached to the fi xed part of the safety guard, the actuator to the moving part. The CTP can be approached from four directions. For the better insertion of the actuator the head is equipped with an integrated funnel. This feature is particularly advantageous on unstable door structures as well as the door is misaligned. On closing the safety guard the actuator enters the head on the safety switch. When the transponder chip integrated into the actuator is detected and the guard locking activated, the safety outputs are switched on. Thanks to the integrated failsafe locking mechanism unintentional activation of the safety outputs is prevented if the actuator is not completely inserted in the head.

CTP in detail Robust metal head locking force 2500 N Dirt resistance Degree of protection IP 69K can be used universally in industrial sectors Integrated funnel for easy insertion of the actuator in the safety switch 4 approach directions Auxiliary release for unlocking the guard locking with the aid of a tool Immediate diagnostic functions permit quick determination of the device status using LEDs Robust fiber glass reinforced plastic housing for usage under hardest conditions Different plug connectors (M2, M23) reduce the wiring work Compatible mounting with existing safety switches easy to change to CTP without mechanical construction Escape release (optional) unlocking of the guard locking without tools to leave the danger area Actuator made of stainless steel with integrated transponder for unambiguous detection Compact design for space-saving mounting on the safety guard Can be connected in series with up to 20 CTP or other EUCHNER devices in the system family AR M23 or M2

Comprehensive, detailed diagnostics For detailed diagnostics the CTP is equipped with 3 LEDs on the front. These are clearly visible over a wide angle and provide all the important information on the status of the safety switch at a glance. It is also possible to connect monitoring outputs and a diagnostics output to a control system. Different guard locking types Two diff erent types of guard lockings are available on the CTP: Mechanical guard locking Guard locking by spring force. Release by applying voltage to the guard locking solenoid (closed-circuit current principle). For applications in which the protection of persons is required. Electrical guard locking Guard locking by solenoid force. Activation of the guard locking by applying voltage to the guard locking solenoid (open-circuit current principle). Particularly suitable for applications in which only process protection is required. Comprehensive accessories Whether diff erent mechanical releases, pre-assembled cables or diff erent bolt systems, actuators or mounting plates: the comprehensive range of accessories off ers maximum fl exibility during integration and mounting. Bolt systems Mechanical key release Emergency unlocking Lockout bar (for up to 3 locks) Wire front release

System family AP In the version AP the CTP is suitable for usage as a single device for connection to all common safety evaluation units and safety control systems....4...4 Safe PLC Safety relay...4...4 System family AR PLC seguro Relé de seguridad In the version AR up to 20 safety switches CTP or other EUCHNER products that belong to the AR system family can be connected in series. Two diff erent wiring concepts are available:. Series connection in the control cabinet CES-AR Wiring takes place in the control cabinet. All information about the status of individual CTPs can be forwarded directly to the control system. 2. Series connection in the fi eld For fi eld wiring EUCHNER off ers the option of using M2 plugs and Y-pieces to connect together several CTPs. Instead of the Y-plug connectors it is also possible to use a passive distribution module. On this device all safety and status signals are collected together in the fi eld and forwarded to the control system using one cable....4 Sicherheits- Relais...4...4...4 Safe PLC Safe PLC Safety relay Safety relay CES-AR PLC seguro CES-AR Relé de seguridad Sicherheits- Relais

Technical data CTP Parameter Value Unit Housing material Degree of protection acc. to EN IEC 60529 Installation position Mechanical life Reinforced thermoplastic IP 69K Any x 0 6 operating cycles Ambient temperature -20 +55 C Approach speed, max. 20 m/min Locking force, max. 2500 N Locking force F Zh according to EN ISO 49 2000 N Weight Approx. 0.5 kg Solenoid operating voltage +0 % depending on type (type designation) - 5 % AC/DC 24 V Duty cycle 00 % Power consumption 8 W Connection Utilization category 2 x plug connectors M2 (8-pin, 5-pin) / M23 (9-pin) AC-5 4A 50 V DC-3 4A 24 V Switching current, max., at 24 V 50 ma Insolation class according to EN IEC 6558 I I I 33 34 44 90 4,5 0 4 37,5 M2x 30 Ø5,3 (4x) M5x35 ISO 207 / ISO 4762

Compatible with existing safety switches The CTP is based on the compact housing of the familiar electromechanical safety switches. Thanks to the compatible fi xing dimensions the conversion to CTP can be undertaken quickly if necessary. Straightforward compliance with the standards The transponder coding ensures the highest safety. With only one CTP the requirements in all relevant standards can be met. Independent of whether category 4 / PL e according to EN ISO 3849- needs to be achieved or the requirements of EN ISO 49 must be met with the CTP you are always on the safe side. Different coding levels Unicode coding Each CTP actuator has a unique code and signifi cantly surpasses the requirement in EN ISO 49 for a type 4 switch with high coding level. The uniquely coded actuator is specifi cally assigned to the safety switch via a teach-in operation. As such bypassing the safety guard using another actuator of the same type is eff ectively prevented. In this way the requirement in the standard for eff ective protection against tampering is met. If a fault occurs, a new actuator can be taught-in at any time. On teaching-in the new actuator the previous actuator automatically ceases to be valid. Multicode coding For applications in which an actuator with a high coding level is not necessary, it is of course possible to use a multicode safety switch. The actuator is not specifi cally assigned to the safety switch here. It is only checked whether or not the actuator is a valid actuator. Locking force 25000 N Secure against defeating EN ISO 3849 Cat. 4 / PL e Degree of protection IP 69K Compact design n EN ISO 49

www.euchner.com The advantages of the CTP at a glance Category 4 / PL e according to EN ISO 3849- Degree of protection IP 69K Compact design Compatible mounting with existing safety switches High locking force of 2500 N Comprehensive accessories Secure against defeating Less wiring work Up to 20 CTP can be connected in series Fault exclusion not necessary Comprehensive and detailed diagnostics CTP with bolt and mechanical key release CTP with wire front release 23244-0-/4 Subject to technical modifi cations; no responsibility is accepted for the accuracy of this information. EUCHNER GmbH + Co. KG TA CTP with emergency unlocking CTP with hinged actuator Available from spring 205 EUCHNER GmbH + Co. KG Kohlhammerstraße 6 7077 Leinfelden-Echterdingen Germany Tel. +49 7 7597-0 Fax +49 7 75336 info@euchner.de www.euchner.com