EntraGuard Titanium Telephone Entry Controller Installation Guide. 1.0 Drawings

Similar documents
Basic ASSA Aperio Configuration Application Note

1.0 Wiring and Layout Diagrams

1.0 PXL-500 Family Controllers

DoorsNXT Remote Port Change Reference Document. 1.0 DoorsNXT Server and Client On The Same PC

The following are basic setup instructions for the LAN-520 AESP. Some settings may not apply to every application.

1.0 Detaching an SQL Database

1. Open the License Manager either via the Start Menu or from C:\Keri\DoorsNET directory.

1.3 Operating Conditions -40 F to 150 F (-40 C to 65 C) 0% to 90% Relative Humidity, non-condensing

1.0 Installation Guide

TB21. NO - Relay. Relay. Common - Relay. NC - Relay. Input J23. Ground TB22 TB23. NO - Relay Common - Relay NC - Relay Input Ground.

Doors.NET License Manager and Gateway Configuration Application Note

Doors.NET TM Software v Release Notes. 1.0 Doors.NET TM Software Release

Doors.NET TM Software v Release Notes. 1.0 Doors.NET TM Software Release

The first step is to ensure the Time and Attendance Interface is enabled in the license

Basic Mercury Powered NXT Controller Configuration

Recommended Peripherals List PXL / Entraguard Product Families

Doors.NET Database Detach and Attach

NXT Controller Manual IP Assignment in WAN Environments Application Note

This document describes the standard software installation process for Doors.NET software.

Allegion AD-300 Installation Application Note. 1.0 Hardware Requirements. 2.0 Software/Licensing Requirements

NXT-1R/-3R/-5R Exit Reader Installation Drawing 4-Conductor - OR - CAT-5 Cabling. IO-Plus (Green) Ground (Black) +12 VDC (Red) Shield (Silver)

Intelligent Security & Fire Ltd

USB Enrollment Reader

Troubleshooting and Diagnostics

Troubleshooting and Diagnostics

A summary of the setup process is listed below with details for each step following.

PXL-250 Tiger Controller

Doors v4.11 contains four fixes. For details, see Features and Improvements on page 2.

1.0 Doors Due to the quick release of Doors v4.54 following Doors v4.53, information for both releases is included here.

For proper operation of Doors software, all controllers on the access control network must meet the following requirements.

3. A system backup utility has been added to the Doors software package. This utility (identified

PXL-500/PXL-510: Firmware v8.4.30

BioPointe Reader Installation Guide

EntraGuard Bronze. Quick Start Guide. Telephone Entry. 1.0 Specifications. 2.0 Unit Installation

The Future of Proximity Access Control

Owner s Manual. 1833, 1834, 1835, 1837 PC Programmable Telephone Entry and Access Control Systems

LC SERIES OPERATING INSTRUCTIONS MODELS LCLX, LCMX, TLCL, TLCM

LAN-505 Ethernet Communication

MS-4000: ShootingStar Reader

IntelliPr ox 2000 KEYLESS ENTRY SYSTEM TO MANAGE ACCESS TO A SINGLE DOOR FOR UP TO 500 USERS NOW WITH D-LITE SOFTWARE

DO NOT LOSE THIS SHEET - YOUR FACTORY MASTER CODE IS UNIQUE TO YOUR KEYPAD

Recommended Peripherals List

MS-3000 MicroStar Reader

BioPointe Finger/Card Presentation

PROGRAMMING AND USE INSTRUCTIONS FOR THE OVATION SYSTEM

MS-7000: SuperStar Reader

MS-5000 MiniStar Reader. Quick Start Guide MS The MS-5000 MiniStar Reader. 1.0 Specifications

LiteKeeper 4. Stand Alone Lighting Control Panel Technical Specifications PART 1. GENERAL 1.01 INTRODUCTION 1.02 DESCRIPTION OF WORK

AT89C5131 Starter Kit... Software User Guide

DESIGN GUIDE FOR INFINITY SYSTEMS

Quick Start Installation Guide

GETTING STARTED. Installing the System 2000 Hardware. Configuring Your System 2000 Hardware. Troubleshooting. Configuring Your System 2000 Network

AF Upgrade Instructions

AeGIS 8000 Series. Management Software

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO D ISSUED NOVEMBER 2002 VERSION 2.

KEYPAD ONLY SETUP INSTRUCTIONS

MS-5000: MiniStar Reader

ENGLISH ATRIUM. Quickstart Web Guide v4.20. The Installer s Choice cdvigroup.com

Catalyst. Your all-in-one data logging and remote monitoring solution

1:5 Combo msata HDD Duplicator (MSHDUS5HS)

X1/X2 TDL Gateway Software Release Notes

CM-500 SK 500 USER CODES KEYPAD

USERS MANUAL.

Operating Manual QUESTOR

Oldham OLCT 200 Revision 1

Troubleshooting & Repair

CT9000 Standalone FingerPrint Time Attendance System. User Manual

LiteKeeper 8. Stand Alone Lighting Control Panel Technical Specifications PART 1. GENERAL 1.01 INTRODUCTION 1.02 DESCRIPTION OF WORK

The Pyramid Series features five readers, each with its own unique characteristics, to meet virtually any requirements an end-user may have.

EcoEntry. RFID Proximity Access Control System. User Guide. Revision 2

Door Access System. User Manual

Andover ContinuumTM Infinet II

UC-2000 Installation Manual Unicorn Computers Technology Limited

AUDITGARD. LGA Electronic Combination Locks. manager instructions PROGRAMMABLE LOCK FEATURES STANDARD LOCK FEATURES

CM500 High Speed Cable Modem User Manual

Maximizing revenue with in-service testing centralized testing/monitoring systems. Application note

DOORKING SYSTEMS. PROGRAMMING OVERVIEW Programming from System Keypad Programming through Software Communication from PC to Controller

Introduction. Tech Note 941 Resetting a Non-Responsive Intermec CK61 Device. At times your Intermec CK61 handheld computer can become non-responsive.

Installing the DX LCD Display

IP Controller INSTRUCTIONS

Size of Mounting Plate /2 inches High x 7 inches Wide x 3 1/16 inches Deep (includes circuit boards)

Data Highway allows you to communicate with a variety of devices, including: programmable controllers computers RS-232-C/ RS-422 devices Fisher

High Speed Cable Modem

(Cat. No SR) Product Data

T E C H N O L O G I E S. User Guide. 1:1 HDD Duplicator PRO (HDUSI325)

Knowledge Base Article. Integrating ISONAS Access Control System with TagMaster LR-series RFID Readers

SCD Live SPEED TECH A/S

BACnet. b3810 Series Local Controllers

Polycom Communicator Software Version 2.1 for PVX 17 September 2007

T E C H N O L O G I E S. User Guide. 1:9 HS HDD Duplicator Pro (HD9SITDRHS)

T E C H N O L O G I E S. User Guide. 1:5 HDD/SSD Duplicator Deluxe C (HD5SNDXHS, HDUS5SNDX)

Allen-Bradley Real Time Clock Module (Cat. No DC)

Digiplex IV Matrix Switching System

Card Nest Universal 12 position card nest for all K-AB cards above and all other K-AB cards.

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA UM Channel Monitor.

RFID PRODUCT AND SYSTEM

What's New In Doors.NET Version 4.0.3

FlashMaxII Operation Guide

Setup Instructions. LA GARD ComboGard Pro 39E Electronic Lock

2 IDS LCD Keypad User Manual C Issued March 2009

Transcription:

This installation guide provides basic installation information, drawings, and controller setup instructions to use when installing the EntraGuard Titanium Telephone Entry controller. The EntraGuard Titanium controller may be used alone or may be connected to an access control network using PXL-500 or PXL-250 family controllers. For instructions on how to install a postal lock, see the EntraGuard Titanium Postal Lock Installation Application Note (P/N 01964-001). NOTE: It is the responsibility of the installation organization to have only technically qualified personnel performing the installation. Section 1 - Drawings Section 2 - RS-232 Serial Port Section 3 - Setup Controller Section 4 - Contact Keri Systems 1.0 Drawings Figure 1: The EntraGuard Titanium Telephone Entry Enclosure Page 1 of 6

Figure 2: The Titanium Telephone Entry Controller NOTE: You must power down the unit before attempting to make or remove any connections. Failure to do so will damage the controller. NOTE: You must set Jumper 11 if you intend to use the Titanium controller s internal modem. Page 2 of 6

2.0 RS-232 Serial Port An RS-232 serial connection between the EntraGuard unit and the host computer can be done one of two ways: by a direct serial connection (50 feet maximum) through an external modem 2.1 Direct Serial Connection The Keri Systems part number for this cable is KDP-552. Figure 3: PC/DB-9F to Telephone Entry/TB-12 RS-232 Direct Serial Connections 2.2 Modem Connection The Keri Systems part number for this cable is KDP-929M. Figure 4: Modem/DB-9M to Telephone Entry/TB-12 Serial Port Connection Page 3 of 6

3.0 Setup Controller If you're turning system power on for the first time, certain tasks must be performed prior to entering access control information from Doors. On the EntraGuard Titanium main board (see Figure 2 on page 2), hold the Reset Button (SW1) down and turn the controller s power on. After the controller beeps once, indicating the controller s firmware is ready for programming, release the SW1 button. The LCD on the front panel will display the Reset Menu (see Figure 5). From this menu you may perform these tasks: set the controller s address, clear the controller s memory, set the microphone volume, and check diagnostics. Figure 5: Reset Menu NOTE: If no keys have been selected within 60 seconds, the unit will time out and go directly to the default message. In order to reach the Reset Menu, the unit must be powered up again. 3.1 Set Unit Address The controller s address may only be set through the Reset Menu. Once you have performed the necessary steps to reach the Reset Menu as described above. To set the desired operating address for the controller, press 1 on the keypad. The Set Panel Address screen appears on the LCD (see Figure 6). Figure 6: Set Unit Address The address range is from 1 to 128. The Master Controller must be set to address 1. Other slave EntraGuard/PXL controllers may be assigned any number from 2 to 128. If the network is made up of PXL-250s, the EntraGuard Titanium must be set as the Master. If the address shown as Current is correct, you may either enter the same address and press *, or just press * to return to the reset menu. If you do not enter a new address, or enter the same address that is already assigned to this unit, you will need to clear the memory separately (see Clear the Controller s RAM on page 5). NOTE: Changing the address of an EntraGuard Titanium controller completely erases all information within the controller. It is vitally important that you collect all event data from the controller before changing the address. Once the address is changed (and the RAM is automatically cleared) the event information in the controller is lost and cannot be recovered. Page 4 of 6

If the address shown as Current needs to be changed, enter the new address by pressing the numbers on the keypad. The number selected will show in the New line. If you enter the wrong number, simply press CLEAR to erase what has been entered. When you are satisfied with the address entered, press *. If you have changed the number from what is shown as Current, the controller will automatically clear the memory as it changes the address (see Figure 7). Figure 7: Clearing Memory Once the memory has been cleared, the unit is ready to be configured. The LCD will display a warning that the unit has not been initialized. This display will rotate with the EntraGuard Default display until a Total Update from Doors has been performed on the unit. Once an update has been performed, only the default will be displayed. 3.2 Clear the Controller s RAM When turning system power on for the first time, the controller s memory needs to be cleared of any spurious information that may be in the RAM. If you changed the controller address, the memory is automatically cleared. However, if you did not change the address, you will need to clear the controller s RAM separately. From the Reset Menu (see Figure 5 on page 4), press 2 to Clear Memory. The Clear Memory screen will appear on the LCD (see Figure 8). Figure 8: Clear Memory From the Clear Memory Screen you may either: 1. Press 1 to clear the controller s RAM. The LCD will change to show the memory is being cleared (see Figure 7). Once the controller s RAM has been cleared, the unit is ready for use. The LCD will rotate between the Initialization Warning and EntraGuard Default screens until a Total Update from Doors has been performed on the unit. or 2. Press 2 to return to the Reset Menu without clearing the controller s RAM. NOTE: Clearing the system RAM completely erases all information within the EntraGuard Titanium controller, except for the controller address. If there is any information in system RAM from an access control installation and the system RAM is cleared, the information in the controller is lost and cannot be recovered, and a Total Update must be performed. Page 5 of 6

3.3 Diagnostics and Troubleshooting For information regarding the diagnostics screens and troubleshooting the EntraGuard Titanium Controller, see the EntraGuard Troubleshooting and Diagnostics Guide (P/N 01912-001). 4.0 Contact Keri Systems Keri USA 2305 Bering Drive San Jose, CA 95131 Keri UK, Ireland, Europe Unit 17 Park Farm Industrial Estate Ermine Street Buntingford Herts SG9 9AZ UK Telephone: (800) 260-5265 Telephone: + 44 (0) 1763 273 243 (408) 435-8400 Fax: (408) 577-1792 Fax:+ 44 (0) 1763 274 106 Web: www.kerisys.com Web:www.kerisystems.co.uk E-mail: sales@kerisys.com techsupport@kerisys.com E-mail:sales@kerisystems.co.uk tech-support@kerisystems.co.uk - end of document - Page 6 of 6