MCIS DNC Cell/Plant SINUMERIK. Motion Control Information System MCIS DNC Cell/Plant. Introduction 1. Prerequisite. Installation 3.

Similar documents
Readme SiVArc V14 SP1 Update 6

Team engineering via Inter Project. Engineering. TIA Portal. Team engineering via Inter Project Engineering. Basics of "Inter Project Engineering"

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library 1. Deleting program block Main [OB1]

MCIS DNC IFC SINUMERIK. Motion Control Information System MCIS DNC IFC. Introduction 1. Requirements. Installation 3. User administration 4

SIMATIC. Process Control System PCS 7 VT Readme V8.2 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

party software COMOS Platform Third-party software Trademarks 1 Requirements for the system environment Third-party software releases Operating Manual

Class documentation. COMOSKDictionary COMOS. Platform Class documentation COMOSKDictionary. Trademarks. General. KDictionary. Programming Manual

PD PA AP How To Configure Maxum II TimeServer Access

B.Data V6.0 Installation SIMATIC. B.Data V6.0 Installation. Introduction. Installing B.Data. Setting up B.Data Web 3

SIMATIC. Process Control System PCS 7 PCS 7 system documentation - Readme V8.0 SP2 (Update 1) Options for Accessing Documentation 1

Quick Start powermanager SENTRON. Software Quick Start powermanager. Introduction. Installation. Starting the project 3

MindSphere. Visual Explorer. Introduction. User roles for "Visual Explorer" Connecting "Visual Explorer" to MindSphere data. Creating Visualizations

Software Kit. Automatic Door Controls. SIDOOR Software Kit. Introduction 1. General safety instructions. Installation. Uninstalling the software 4

General Information 1. Connection 2. User Interface 3 ATC5300. Menus 4. Automatic Transfer Controller. Remote Control Software Manual A5E

COMOS. Platform Class documentation RevisionMaster_dll. Class: RevisionInfo 1. Class: RevisionMaster 2. Programming Manual

SIMATIC. S7/HMI SIMATIC Automation Tool V3.1 SP1 product information. SIMATIC Automation Tool features 1. Known problems. Product Information

SIMATIC. Industrial PC Microsoft Windows 7 (USB stick) Safety instructions 1. Initial startup: Commissioning the operating system

SIMATIC. Process Control System PCS 7 Trend Micro OfficeScan (V8.0; V8.0 SP1) Configuration. Using virus scanners 1.

SINEMA Remote Connect - Client SIMATIC NET. Industrial Remote Communication SINEMA Remote Connect - Client. Preface. Requirements for operation

Key Panels Library SIMATIC HMI. Key Panels Library. Preface 1. Installation of Key Panels Library. Working with the Key Panels Library

SIMATIC. Process Control System PCS 7 Symantec Endpoint Protection 11.0 Configuration. Using virus scanners 1. Configuration 2. Commissioning Manual

SIMATIC NET. Industrial Remote Communication - Remote Networks SINEMA Remote Connect - Client. Preface. Requirements for operation 1

B.Data V6.0 SP1 Installation SIMATIC. B.Data V6.0 SP1 Installation. Introduction 1. Installing B.Data. Setting up B.Data Web

Performance data abgn SCALANCE W770/W730 SIMATIC NET. Industrial Wireless LAN Performance data abgn SCALANCE W770/W730.

Class: DocumentManager 1 COMOS. Platform Class documentation DocumentManager_dll. Programming Manual 03/2017 V10.2.

Performance data abgn PCIe Minicard MPCIE-R1-ABGN-U3 SIMATIC NET

SIMOTION. Motion Control Task Trace. Preface 1. Overview 2. Configuring 3. Working with the SIMOTION Task Profiler 4.

Primary Setup Tool (PST) SIMATIC NET. Industrial Ethernet / PROFINET Primary Setup Tool (PST) Preface. Description. Software installation 2

SIMATIC. Industrial PC Microsoft Windows 7. Safety instructions 1. Initial startup: Commissioning the operating. system

S7-300 Getting Started - Commissioning a CPU 31xC: Closed-loop control

Optional package printer driver V1.4

Siemens Spares. Setting up security in STEP 7. Professional SIMATIC NET. Industrial Ethernet Security Setting up security in STEP 7 Professional

SIMATIC. Process Control System PCS 7 CFC Readme V9.0 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

MindSphere. MindConnect IoT Extension Getting Started. Introduction to MindSphere. Prerequisites 2. Preparations 3. MindConnect IoT Extension

SITOP UPS1600 under STEP 7 V13. SITOP UPS1600 under STEP 7 V13. Introduction. Safety notes. Description. Assigning the IP address

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

SIMATIC. STEP 7 PLUS TIA Portal Teamcenter Gateway. Introduction to TIA Portal Teamcenter Gateway 1. System requirements 2

Getting Started - Startdrive. Startdrive SINAMICS. Introduction 1. Connecting the drive unit to the PC. Creating a project 3

SIMATIC NET. Industrial Ethernet / PROFINET Primary Setup Tool (PST) Preface. Functions 1. Software installation 2. Operation. Configuration Manual

SIMATIC. SIMATIC Logon V User management and electronic signatures 1. Hardware and Software Requirements 2. Scope of delivery 3.

SIMATIC. Process Control System PCS 7 Configuration McAfee Endpoint Security Security information 1. Preface 2.

Setting up securityglobal FW Rulesets SIMATIC NET. Industrial Ethernet Security Setting up security. Preface. Firewall in standard mode

SIMATIC. Industrial PC Microsoft Windows Embedded Standard 7. Safety instructions 1. Initial startup: Commissioning the operating.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

SINETPLAN Siemens Network Planner

SIMATIC IPC Wizard for. Widescreen devices with multitouch SIMATIC. Industrial PC SIMATIC IPC Wizard for. Preface.

Portable & Direct COMOS. Operations Portable & Direct. Trademarks 1. Introduction. Portable 3. "Direct" plugin 4. User interface reference

SIMATIC HMI. Software RemoteOperate V2. Preface. Overview 1. Range of functions of the RemoteOperate software. Hardware and software requirements

SIMATIC. Process Control System PCS 7 Configuration Symantec Endpoint Protection V14. Security information 1. Preface 2.

SIMATIC. Process Control System PCS 7 SIMATIC Management Console (V9.0) Security information 1. Preface 2. Basics 3

SIMATIC. PCS 7 Process Control System SIMATIC Logon Readme V1.6 (Online) Security information 1. Overview 2. Notes on installation 3.

Settings. Prior information notice 1. Introduction to "Settings" 2. User rights in "Settings" 3. Settings interface 4.

Class: POptions 1 COMOS. Platform Class documentation POptions_dll. Programming Manual 04/2014 A5E AA

SIMATIC. SIMATIC Energy Manager V1.0 App for ios and Android. Preface. SIMATIC Energy Manager app. Establish connection to SIMATIC Energy Manager PRO

First Steps in Commissioning CPU. 31xC: Positioning with digital output SIMATIC

Operator Station (V8.0) SIMATIC. Process Control System PCS 7 Operator Station (V8.0) Preface 1. The PCS 7 Operator Station

Block Library Motor Starter SIRIUS for SIMATIC PCS 7

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

SITOP UPS1600 under STEP 7 V5. SITOP UPS1600 under STEP 7 V5. Introduction. Safety notes. Description 3. Assigning the IP address

SIMATIC. Process Control System PCS 7 SIMATIC Management Console (V9.0 Update 1) Security information 1. Preface 2. Basics 3

RF-MANAGER simulator SIMATIC. RFID-Systems RF-MANAGER simulator. Simulating projects. Compact Operating Instructions 06/2010 A5E

SIMOTION. SIMOTION SCOUT Task Trace. Preface 1. Overview 2. Configuring 3. Working with the SIMOTION Task Profiler. Function Manual 05/2009

SIMATIC. Process Control System PCS 7 Advanced Process Functions Operator Manual. Preface. Security information 1. Overview 2. Material management 3

SENTRON powermanager. Low-Voltage Power Distribution and Electrical Installation Technology Software SENTRON powermanager.

SIMATIC Ident RFID systems MDS D423 Compact Operating Instructions

DI 8x24VDC ST digital input module SIMATIC. ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Preface. Documentation guide

Siemens Drives & PLCs

Maintenance COMOS. Platform Maintenance. Trademarks 1. Information on version change. Switching the licensing technique

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Readme

SIMATIC NET. Industrial Ethernet Security SCALANCE S615 Getting Started. Preface. Connecting SCALANCE S615 to the WAN 1

Configuration limits for products of the SIMATIC NET PC Software V8.1 SIMATIC NET

COMOS. Operations Shutdown. Introduction 1. Milestones 2. "Shutdown management" plugin 3. "Quick edit" plugin 4. User interface reference 5

SIMATIC. SIMATIC Logon V1.6. Security information 1. Conditions for secure operation of SIMATIC Logon 2. User management and electronic signatures 3

Siemens Spares COMOS. Operations Inspection. Introduction 1. Working with the "Inspection" plugin 2. Working with the "Inspection diagram" plugin 3

Continuous Function Chart Getting. Started SIMATIC. Process Control System PCS 7 Continuous Function Chart Getting Started.

SIMATIC. Process control system PCS 7 Operator Station (V9.0 SP1) Security information 1. Preface 2

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

CP 1623 SIMATIC NET. PG/PC - Industrial Ethernet CP Preface. Description of the device. Software installation. Hardware installation

Siemens Industrial SIMATIC. Process Control System PCS 7 Configuration Trend Micro OfficeScan Server XG. Security information 1.

SIMATIC. Process Historian 2014 SP2 SIMATIC Process Historian. Process Historian - Installation Notes 1. Process Historian - Release Notes

Process Historian Administration SIMATIC. Process Historian V8.0 Update 1 Process Historian Administration. Basics 1. Hardware configuration 2

SIMATIC. Process Control System PCS 7 OS Process Control (V8.1) Preface 1. Additional documentation 2. Functions of the PCS 7 OS in process mode 3

SIMATIC. Industrial software WinAC RTX F Introduction 1. Selecting suitable hardware 2. Installing/removing the WinAC RTX F 2009 software

SIMOCODE pro. Read me SIMOCODE ES. Introduction 1. Installation notes 2. Installation/License key/ Uninstallation 3.

Siemens Automation Products

COMOS. Operations Inspection. Introduction 1. Working with the "Inspection" plugin 2. Working with the "Inspection diagram" plugin 3

COMOS. Lifecycle Material Management. General information 1. Introduction 2. Definitions 3. Creating material in COMOS 4

First Steps with S7-PDIAG and ProAgent

SIMATIC. PCS 7 process control system OpenPCS 7. Preface 1. Basics 2. Installation and licensing 3. PCS 7 Engineering 4. System configurations 5

COMOS. Automation COMOS Automation Interfaces SPI 1. Generic Excel import 2. Process visualization via OPC client 3.

SIMATIC. WinCC Readme Runtime Professional. Validity 1. Improvements in Update 2 2. Improvements in Update 1 3

SIMATIC Automation License Manager Manual 02/2008 A5E

Web Option for OS (V8.0) SIMATIC. Process Control System PCS 7 Web Option for OS (V8.0) Preface 1. Additional documentation

SIMATIC. ET 200SP Open Controller Product information on CPU 1515SP PC. Preface. Product Information. Technical update. Technical specifications 3

COMOS Material Management. Operation COMOS. Process COMOS Material Management Operation. Trademarks 1. Introduction. Definitions 3

SIMATIC. Communications processor CP First Steps in Commissioning. Getting Started 09/2008 A5E

SIMATIC. WinCC Readme Runtime Professional. Validity 1. Improvements in Update 7 2. Improvements in Update 6 3. Improvements in Update 5 4

SIMATIC. Process Control System PCS 7 Licenses and quantity structures (V8.0) Preface 1. Selecting the correct license keys 2

SIMATIC NET. S TeleControl MSC300_Library program block library. Block library for TCSB (V3) WDC_S7_300_... (FB92) 2 UDT_WDC_PARAM (UDT91) 3

COMOS. Automation Automation interfaces. Note on file-based data exchange 1 SPI 2. Generic Excel import 3. Process visualization via OPC client 4

Transcription:

Introduction 1 Prerequisite 2 SINUMERIK Motion Control Information System Installation Manual Installation 3 Update of DNC 4 Uninstalling DNC 5 Configuring Windows XP with Service Pack 2 6 Code conversion table 7 Automatic import of NC programs 8 Installation of the eight-port card in a PC 9 NC data comparison and parameterization of FTP for 10 SINUMERIK Problem solutions, tips and tricks 11 Valid for SINUMERIK 840D sl / 840DE sl Software version 2.4.1 as of SINUMERIK Operate for PCU as of SINUMERIK Operate for NCU 2.6 SP1 HF5 2.6 SP1 HF6 09/2011

Legal information Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken. CAUTION without a safety alert symbol, indicates that property damage can result if proper precautions are not taken. NOTICE indicates that an unintended result or situation can occur if the relevant information is not taken into account. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. Trademarks All names identified by are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Industry Sector Postfach 48 48 90026 NÜRNBERG GERMANY P 10/2011 Copyright Siemens AG 2011. Technical data subject to change

Table of contents 1 Introduction... 5 2 Prerequisite... 7 2.1 Licensing...8 3 Installation... 9 3.1 Installing DNC...9 3.2 Installing PC as MCIS server...12 3.3 Installing PC as operator control and data acquisition computer...18 4 Update of DNC... 23 5 Uninstalling DNC... 29 6 Configuring Windows XP with Service Pack 2... 33 7 Code conversion table... 35 8 Automatic import of NC programs... 37 9 Installation of the eight-port card in a PC... 39 10 NC data comparison and parameterization of FTP for SINUMERIK... 41 11 Problem solutions, tips and tricks... 43 11.1 Documentation on the CD-ROM...43 11.2 DNC Cell/Plant with MCIS DNC IFC...43 11.3 Changing the background colors for DNCAdmin...44 11.4 "Machine comparison" function for SINUMERIK with PCU/MMC103...44 11.5 Passwords and user logins...44 Installation Manual, 09/2011 3

Table of contents 4 Installation Manual, 09/2011

Introduction 1 DNC Cell/Plant The DNC host computer system is used to connect networked and serial machines. A PC can be connected to DNC Cell. The management functions can only be operated from this PC. Several CNC machines can be connected to DNC Plant. The CNC data is managed on a central server. Installation Manual, 09/2011 5

Introduction 6 Installation Manual, 09/2011

Prerequisite 2 Installing You need administrator rights to perform the installation. You will also need knowledge for the installation of software under Windows and operation of the operating system. PC operating system The following operating systems are required for the PC: Windows XP Professional SP3 Windows 2003 Server Note Error message under Windows XP Professional SP2 If installed under Windows XP Professional SP2, you receive the error message: "MCIS DNC cannot be installed on this operating system." Hardware Up-to-date information about main memory, processor, disk space can be found in the following documentation: "FB_DNC_V24.PDF" in the "Doc\English" directory on the CD-ROM Installation Manual, 09/2011 7

Prerequisite 2.1 Licensing 2.1 Licensing MCIS DNC licensing The General License Conditions of Siemens AG automation engineering can be found on the CD-ROM in the appropriate national language under <CD-ROM>:\License_xy-XY.txt (xy represents the language code, e.g. en = English). Licensing DNC Plant The supplied CD-ROM contains, in addition to the DNC Plant software, including documentation, also the software of the SQL Express 2005 database. The supplied license certificate is proof that the DNC Plant and SQL Express software have been purchased correctly. The Microsoft SQL Express database used in DNC Plant is subject to the license conditions of Microsoft Corporation. The key required for the installation is printed on the license certificate. Licensing DNC Cell The supplied CD-ROM contains the DNC Cell software, including documentation, and authorizes the connection of one CNC controller. The supplied license certificate is proof that the software has been purchased correctly. Additional licenses are required when more than one controller needs to be connected. A maximum of 16 serial SINUMERIK, and also 16 SINUMERIK over the network, are possible. The used Microsoft SQL Express database is subject to the license conditions of Microsoft Corporation. The key required for the installation is printed on the license certificate. 8 Installation Manual, 09/2011

Installation 3 3.1 Installing DNC Procedure 1. Start "SetupDNC.exe" from the installation directory of the CD-ROM. The "Choose Setup Language" window opens. 2. Select a setup language. This language is binding only for the installation. The following languages are listed: English German 3. Click "OK" to confirm the selection. Installation Manual, 09/2011 9

Installation 3.1 Installing DNC 4. You will receive a welcome dialog. Click "Next >" to confirm the dialog. The installation will be prepared. 5. Click the "I would like to read the information" button to display the product information in the "Readme.rtf". After you have read the information, click the "Next >" button. 10 Installation Manual, 09/2011

Installation 3.1 Installing DNC 6. The "License Agreement" window opens. Agree to the license agreement and click the "Next >" button. 7. In the next window start with the following installation: MCIS - Server Cell (single user installation), see Installing PC as MCIS server (Page 12) Operator PC, see Installing PC as operator control and data acquisition computer (Page 18) Installation Manual, 09/2011 11

Installation 3.2 Installing PC as MCIS server 3.2 Installing PC as MCIS server Procedure 1. The "Select Product Type" window opens. Select the "MCIS server" installation type. Place a check mark for "Cell (single user installation)" If a controller is connected with SINUMERIK Operate, select the "Solution line support act." option. Note It is not possible to activate "Solution line support act." after the installation. If you still want to set the option, you must first uninstall DNC Cell. See Uninstalling DNC (Page 29) To select the option, before installation on the PC, you must have previously installed a "Microsoft Internet Information Service (IIS)". If "IIS" is not installed, you will receive a message that you must acknowledge with "OK". 12 Installation Manual, 09/2011

Installation 3.2 Installing PC as MCIS server Click "Next >" to continue. 2. The target folder in which "MCIS DNC" will be installed is displayed in the next window. 3. If you want to change the storage location, click the "Change... " button. Note You can change the target folder only if no MCIS application has been installed. Installation Manual, 09/2011 13

Installation 3.2 Installing PC as MCIS server The "Change Current Target Folder" window opens. Select a new target folder and click "OK". 4. The "Target Folder for MCIS" window reopens and the new storage path displayed. Click "Next >" to continue installing the software. Database server All MCIS products share a common database. Some tables of this database, for example the user administration and plant hierarchy tables, are used by all products. The SQL database is available as a free version on the CD-ROM and, depending on the selection, automatically installed and configured by the setup. In principle, a distinction is made between a new installation or selection of an already installed database server. At the beginning of the installation, a check is made as to whether a database server has already been installed. If a database server has still not been installed on the target system, then setup installs the "SQL 2005 Express SP2" version. Note If SQL Express is already present on the system, setup will bypass this installation. If an older version of a database is already installed, you will receive an appropriate error message. 14 Installation Manual, 09/2011

Installation 3.2 Installing PC as MCIS server 5. The "Database Server" window opens. Accept the default settings in the "Database server on which you install" selection box. Select "Windows authentication of the current user". 6. Click "Next >" to start the installation of the database server and the configuration of the table. Installation Manual, 09/2011 15

Installation 3.2 Installing PC as MCIS server Starting the installation 7. After successfully establishing a connection, start with the installation. Click the "Install" button. 8. The installation is started and the procedure is displayed on a progress bar. 16 Installation Manual, 09/2011

Installation 3.2 Installing PC as MCIS server 9. Click "Finish" to complete the installation. 10. A restart is required after the installation of DNC. Click "Yes" to reboot the PC. Installation Manual, 09/2011 17

Installation 3.3 Installing PC as operator control and data acquisition computer 3.3 Installing PC as operator control and data acquisition computer Procedure 1. The "Select Product Type" window opens. Select "Operator PC" as installation type and click "Next >". 2. The next window shows the target folder in which the DNC data will be installed. If you want to change the storage location, click the "Change... " button. Note You can change the target folder only if no MCIS application has been installed. 18 Installation Manual, 09/2011

Installation 3.3 Installing PC as operator control and data acquisition computer The "Change Current Target Folder" window opens. Select the new target folder for the data and click "OK". 3. The "Target Folder for MCIS" window reopens and the new storage paths displayed. Click "Next >" to continue installing the software. Installation Manual, 09/2011 19

Installation 3.3 Installing PC as operator control and data acquisition computer Database server All MCIS products share a common database. Some tables of this database, for example the user administration and plant hierarchy tables, are used by all products. The SQL database is available as a free version on the CD-ROM and, depending on the selection, automatically installed and configured by the setup. In principle, a distinction is made between a new installation or selection of an already installed database server. At the beginning of the installation, a check is made as to whether a database server has already been installed. If a database server has still not been installed on the target system, then setup installs the "SQL 2005 Express SP2" version. Note If SQL Express is already present on the system, setup will bypass this installation. If an older version of a database is already installed, you will receive an appropriate error message. 4. The "Database Server" window opens. Accept the default settings in the "Database server on which you install" selection box. Select "Windows authentication of the current user". 20 Installation Manual, 09/2011

Installation 3.3 Installing PC as operator control and data acquisition computer 5. Click "Next >" to start the installation of the database server and the configuration of the table. Starting the installation 6. After successfully establishing a connection, you can start with the installation. Click the "Install" button. Installation Manual, 09/2011 21

Installation 3.3 Installing PC as operator control and data acquisition computer 7. The installation is started and the procedure is displayed on a progress bar. 8. Click "Finish" to complete the installation. 9. A restart is required after the installation of DNC. Click "Yes" to reboot the PC. 22 Installation Manual, 09/2011

Update of DNC 4 Update to DNC Cell/Plant V2.4.1 The procedure is the same as for a new installation. The update will remove any existing versions of DNC. The DNC data, however, is retained. Note Perform a backup before an update. Procedure 1. Start "SetupDNC.exe" from the installation directory of the CD-ROM. The "Choose Setup Language" window opens. 2. Select a setup language. This language is binding only for the installation. The following languages are listed: English German Installation Manual, 09/2011 23

Update of DNC 3. Click "OK" to confirm the selection. 4. You will receive a welcome dialog. Click "Next >" to confirm the dialog. The installation will be prepared. 24 Installation Manual, 09/2011

Update of DNC 5. Click the "I would like to read the information" button to display the product information in the "Readme.rtf". After you have read the information, click the "Next >" button. 6. The "License Agreement" window opens. Agree to the license agreement and click the "Next >" button. Installation Manual, 09/2011 25

Update of DNC 7. The "Remove Program" window opens. Click "Remove" to uninstall the data for the previous DNC version. 8. The procedure is displayed in a progress bar. 26 Installation Manual, 09/2011

Update of DNC 9. The "InstallShield Wizard Completed" window is displayed. Now click "Finish" to close the installation. Installation Manual, 09/2011 27

Update of DNC 28 Installation Manual, 09/2011

Uninstalling DNC 5 Introduction You have the following two options to uninstall DNC Cell/Plant on the PC: Using DNC Uninstall From the Windows control panel DNC Uninstall 1. Select Start Programs MCIS DNC Uninstall. 2. You then receive a confirmation prompt. Click "Delete data" to uninstall the program. Installation Manual, 09/2011 29

Uninstalling DNC Windows control panel 1. From Start Settings Control Panel Software, select the "MCIS DNC" program. The "Add or Remove Programs" window opens. Click the "Remove" button. 2. The installation wizard is invoked. Click "Next >". 30 Installation Manual, 09/2011

Uninstalling DNC 3. The "Program Management" window opens. Select the "Remove program" option and click "Next >". 4. The "Remove Program" window is displayed. Use the "Delete DNC data" checkbox to define whether the data should be retained or deleted. Click the "Remove" button to uninstall the software. Installation Manual, 09/2011 31

Uninstalling DNC 5. Now click "Finish" to complete the uninstallation. 32 Installation Manual, 09/2011

Configuring Windows XP with Service Pack 2 6 Customizing the firewall As of Windows XP Service Pack 2, greater emphasis is placed on increased security. For this reason, after the installation of DNC, changes must be made to the operating system in order to enable communication with other computers. If machines are connected via a network, changes must be made in the integrated Windows XP firewall so that they can be accessed. Procedure Open the Control Panel (Start Settings) and double-click the "Windows Firewall" entry. If the firewall is "Active", the "Do not allow exceptions" checkbox should not be activated as this blocks the data traffic. Changes for DNC must be in the "Exceptions" tab for the network access to function. In order to grant access to the file system, place the check mark for "File and Printer Release". If the server is accessed from a PC with DNC, the network port of the database must be opened there (Microsoft SQL 2005 Express port: 1433). With Microsoft SQL 2005 Express, access must then be activated via network protocols ( "C:\Programs\Microsoft SQL Server\80\Tools\Bin\SVRNETCN.exe", set TCP/IP to "enable"). Installation Manual, 09/2011 33

Configuring Windows XP with Service Pack 2 34 Installation Manual, 09/2011

Code conversion table 7 Changes in the code conversion table If changes have been made in the code conversion table, they will only take effect after a restart of the code conversion server or DNC Cell/Plant. Installation Manual, 09/2011 35

Code conversion table 36 Installation Manual, 09/2011

Automatic import of NC programs 8 Starting DNC_Import.exe The "DNC_IMPORT.exe" program is located in the program directory of DNC Cell/Plant. "DNC_IMPORT.exe" can be started as follows: Either by the autostart mechanism (after the login) of Windows 2000/XP. - OR - With the Windows Task Scheduler under Windows 2000/XP or via the "AT" task scheduler routine. Method of operation of the program for automatic import The program checks cyclically whether files with a certain extension are present in a specific folder. The program tries to import these files. The parameters for the program are in the registry: Parameters ImportPath ImportExt SuccessExt ErrorExt DeleteImported DelayTime TraceLevel TraceFilesize Language Description The import directory that contains the file to be imported. The extension of the files to be imported. If DeleteImported=0 is set, this extension must be defined. The file will be assigned this extension after the import. This extension will be set for a faulty import file. Specifies whether the imported files will be renamed or deleted in the import directory: 0 = rename 1 = delete The time in minutes before a new search for import files is made (permitted range 1..1440 minutes). This is used for testing and troubleshooting. Values from 0 to 4 are permitted. This defines the size of the log file in KB. All the actions are logged in a log file maintained in the import directory. Language code EN = English Installation Manual, 09/2011 37

Automatic import of NC programs [HKEY_LOCAL_MACHINE\SOFTWARE\Siemens\MCIS\DNC\ImportSettings] "ImportPath"="C:\\Siemens\\MCIS\\Data\\DNC\\Import" "ImportExt"="IMP" "SuccessExt"="IOK" "ErrorExt"="IER" "DeleteImported"=dword:00000000 "DelayTime"=dword:0000003c "TraceLevel"=dword:00000001 "TraceFilesize"=dword:0000000a "Language"="EN" Call DNC_Import.exe The "DNC_Import.exe" can also be invoked with the "/NOLOOP" start parameter. In this case, the program terminates itself after performing an import run. This parameter should be used when the import is started from the Windows XP/2003 Task Scheduler. Example: With the following calls, an import would be performed four times a day even if nobody is logged in. at 08:00 /every:mo,tu,we,th,fr,sa D:\Programs\Siemens\DNC\DNC_Import.EXE /NOLOOP at 12:00 /every:mo,tu,we,th,fr,sa D:\Programs\Siemens\DNC\DNC_Import.EXE /NOLOOP at 16:00 /every:mo,tu,we,th,fr,sa D:\Programs\Siemens\DNC\DNC_Import.EXE /NOLOOP at 20:00 /every:mo,tu,we,th,fr,sa D:\Programs\Siemens\DNC\DNC_Import.EXE /NOLOOP 38 Installation Manual, 09/2011

Installation of the eight-port card in a PC 9 Installation of the eight-port card in a PC The following settings have been tested and are recommended: I/O port SW1 1-OFF, 2-ON, 3-OFF,4-ON ( 280H... 2B8H ) IRQ port SW2 1-OFF, 2-ON, 3- OFF, 4-OFF, 5-ON, 6-ON, 7-ON, 8-OFF ( 2C0H) IRQ SW3 6-ON ( IRQ=11 ) Under Windows 2000, Windows XP or Windows 2003 The "PC COM PCI BUS 4 Port Serial Adapter" card has been tested for installation under Windows XP and Windows 2000. The driver software is available at the following address: http://www.pccompci.com/driver/8p232.html The driver for Windows 2000 also works for Windows XP. Under Windows XP, all the Com ports are automatically detected and installed successively. The registry entry for "Permit Share" must be set, see Windows NT installation. Installation Manual, 09/2011 39

Installation of the eight-port card in a PC 40 Installation Manual, 09/2011

NC data comparison and parameterization of FTP for 10 SINUMERIK Data transfer Sample file If you install the "DNC Compare" option on the host computer and the DNC IFC software component on a SINUMERIK controller, you will also be able to transfer data from the DNC Cell/Plant to the controller. This option also makes it possible to compare NC data on the DNC system directly with that on the controller (also in the NCK). As standard, this is performed with the help of Microsoft Networking and released network drives. An auto-archive function is integrated in DNC Cell/Plant as standard. This permits the automatic backup of NC data from SINUMERIK controllers to the DNC system. It is also possible to transfer the data via FTP protocol if there is an FTP server in the network or directly on the DNC Cell/Plant computer and secure transmission paths are of prime importance. Parameters Explanation DHPath The path for the MMC/PCU data management from the perspective of the controller (very important!) must be entered. UseFTP Whether or not FTP should be used; values: 1/0 Mode Always set FTP mode to 2 HostIpAddress IP address of the FTP server or its DNS name User FTP user Password Password of the FTP user DHPath=f:\dh ; You can use FTP for file transfer if you have an FTP server ; available in your subnet. UseFTP 0=NO, 1=YES ; Note: You must set the right FTP path in your FTP settings to ; put the files in the DNC Cell/Plant directory UseFTP = 1 [FTP] ; HostIpAddress= (or DNC Cell/Plant computer name) HostIpAddress=daisy2000 User=yourUser Password=yourPassword ; Mode (1=ASCII/2=binary) Mode=2 Installation Manual, 09/2011 41

NC data comparison and parameterization of FTP for SINUMERIK Procedure 1. Create for DNCAdmin a machine of the "840D" type. 2. From the machine properties, open with "Edit" the machine configuration file. 3. Enter the specific parameters for the FTP server and the client for the data transmission. See sample file above. 4. Enter the FTP path name in the Windows registry: Open with administrator rights the Windows registry under "HKLM\Software\Siemens\MCIS\DNC\Settings" You find the "FtpTempPath" and "FtpDataPath" parameters here. You require the "FtpTempPath" parameter to transfer data to the DNC computer in order to perform the program comparison. You require the "FtpDataPath" parameter in order to transfer NC programs from the DNC system to the controller. Enter syntactically correct values in these two parameters in order to access the drives entered here with the help of the FTP user specified in the *.MCF file. Access rights The FTP user must have the following rights: Read and write authorization to the "FtpTempPath" path. Read rights suffice to the "FtpDataPath" path. Example The FTP user name is DNC The FTP password is secret Now enter this user with password in the machine configuration file (*.MCF file) as described above. Use a Windows 2000 FTP server with the "DNC" virtual hard drive. This points to the "c:\siemens\mcis\data\dnc\data" path. You have also created another "DNCTMP virtual drive" that points to the "c:\dnc\tmp" path. Your "DNC" user has read and write rights to both paths. Enter the following values: FtpTempPath = "/DNCTMP" (without "") FtpDataPath = "/DNC" (without "") 42 Installation Manual, 09/2011

Problem solutions, tips and tricks 11 11.1 Documentation on the CD-ROM Information in PDF format If you have any further questions with regard to the functionality of DNC Cell/Plant, we expressly refer to the supplied software documentation in PDF format on the CD-ROM. This requires "Adobe Acrobat Reader" as of V4.0. 11.2 DNC Cell/Plant with MCIS DNC IFC DBServerTask.exe The communication of DNC Cell/Plant with DNC IFC to a controller with PCU is performed with the "DBServerTask.exe" service application. This service application is not started by default under Windows 2000/ XP and is set to "Manual". If necessary, that is, always when DNC IFC is used for communication, change the setting to "Automatic" in the services. Only then is communication from DNC IFC to the DNC Cell/Plant database possible. General conditions with Windows XP SP2 Several general conditions must be observed under Windows XP SP2. A separate document is provided on this CD-ROM for this purpose: <CD-ROM>:Docu\English\IBS_Docu\MCIS-SW-DCOM-plus-Firewall-for-WinXPSP2- ENG.pdf Please note points 1 (general) and 2 (DNC configuration) here. This document is also available for Siemens employees on the Intranet at http://support.automation.siemens.com. Search for it specifically, e.g. for "MCIS" and "FIREWALL". The document is being continually updated, e.g. if new security settings must be observed in the supported Windows systems. Installation Manual, 09/2011 43

Problem solutions, tips and tricks 11.3 Changing the background colors for DNCAdmin 11.3 Changing the background colors for DNCAdmin Changing background colors The background colors can be changed individually. The usual mixture of colors for red, yellow and blue are entered in the following key: [HKEY_LOCAL_MACHINE\SOFTWARE\Siemens\MCIS\DNC\AdminSettings] RGBNormal RGBConfig The values are separated by a comma, e.g. "235, 255, 255" or "135, 125, 140" (violet) 11.4 "Machine comparison" function for SINUMERIK with PCU/MMC103 "DNC Compare" option If the "DNC Compare" option has been purchased together with MCIS DNC IFC, a correct comparison of data on the controller is possible only with the following setting. Set the "DriveInternPath" parameter in the "DNC_IFC.ini" file to the value "0". This ensures that no header information is transferred to the NC data. 11.5 Passwords and user logins Default settings After the installation of DNC Cell/Plant, the following users will have been configured: Name Password Rights DNC DNC Administration programmer programmer Extended user rights worker worker Basic user rights helper helper Limited user rights 44 Installation Manual, 09/2011