Operating instructions Optical distance sensor. OID20x / / 2014

Similar documents
Operating instructions Optical distance sensor. OID20x / / 2015

Operating instructions Optical distance sensor. OID25x / / 2014

Operating instructions Optical distance sensor. OID25x / / 2015

Operating instructions Optical distance sensor. O5D15x / / 2014

Operating instructions Optical distance sensor O1D / / 2012

Operating instructions Optical distance sensor O1D / / 2008

Operating instructions Photoelectric distance sensor OGD592 OGD593

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions IO-Link INLINE DISPLAY 1.44" E30430

Operating instructions. Speed monitor D / / 2014

Operating instructions. Standstill monitor A / / 2011

Operating instructions Diagnostic electronics for vibration sensors VSE002 / VXE002 / VXE003 VYE001 / VYE002 / VYE003 / VYE /01 05/2015

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions IO-Link master CabinetLine AL19xx

Operating instructions Evaluation system for flow sensors VS / / 2013

Operating instructions ClassicLine module AC5203 / AC5205 AC5208 / AC5211 AC5213 / AC5214 AC5215 / AC5233 AC /00 02/2015

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007

Operating instructions. Monitor FD / / 2013

Original operating instructions Photoelectric safety sensors (safety light grid) with active / passive system OY90xS

Installation instructions Inclination sensor EC2019 EC / / 2013

Operating instructions Mechatronic flow sensor SBY2xx SBG2xx SBN2xx SB0524

Operating instructions Control monitor for temperature sensors TR7439

Operating instructions Binary level sensor LMC / / 2014

Operating instructions Electronic temperature sensor TN7511

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Operating instructions Vortex flow meter. SVxxx / / 2015

Operating instructions Electronic pressure sensor PN7xxx

Original operating instructions. Fail-safe SmartPLC with Profinet slave interface AC402S /00 06/2016

Original operating instructions Fail-safe inductive sensor GI712S

Original operating instructions Fail-safe inductive sensor GG711S

Operating instructions. Monitor FS-2 / FS-2N / / 2013

Operating instructions Control monitor for temperature sensors TR /00 04/2011

Operating instructions RFID evaluation unit DTE / / 2016

Operating instructions Electronic pressure sensor. PN72xx PN73xx PN76xx / / 2016

Installation instructions Ethernet switch EC / / 2011

Operating instructions. Monitor FR-1 / FR-1N / / 2013

Operating instructions Electronic temperature sensor TN /00 04/2011

Installation instructions RF-identification system with integrated AS-i slave DTSLF / / 2010

Operating instructions. Monitor FS-1 / FS-1N / / 2013

Brief instructions Illumination unit O3M /00 09/2014

Optical distance sensors. Dimensioned drawing

Operating instructions Pressure sensor. PN70xx / / 2012

Operating instructions Flow sensors SAxx04 SAxx14

Brief instructions Illumination unit O3M950 O3M /00 03/2016

Operating instructions Electronic pressure sensor. PN2xxx / / 2015

Operating instructions Electronic pressure sensor. PN22xx PN26xx / / 2015

Content. Sontheim Industrie Elektronik GmbH Page 2 of 15 07/2016 Installation instructions Version 1.2

Operating instructions Electronic pressure sensor. PM205x /01 09/2011

System manual AS-i safety monitor AC041S /00 05/2013

Technical Data. Dimensions

Operating instructions Encoder PerformanceLine. RxP5xx /00 04/2018

D11 Expert Series 5V dc Models

Operating instructions Pressure sensor. PN50xx / / 2010

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Operating instructions. ProcessLine analogue module AC / / 2012

Optical laser distance sensors. Dimensioned drawing

Technical Data. General specifications. Output type Rated operating distance s n 8 mm

Operating instructions Monitor FD-2 DR2005 DR / / 2007

Quick reference guide 3D sensor O3D3xx

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 5 mm

Instruction manual. Electronic pressure gauge (EPG) IM-TE91K033-EN5. Original manual

DVBus , and Multiplexer and demultiplexer assemblies for video channels USER MANUAL

Operating manual. Series 450. Compact thermometer. BA01235O/09/en/

Installation Guide. O2Ixxx / / 2015

Operating instructions Memory plug E /02 11/2011

XUK8TAKSMM12 photo-electric sensor - XUK - diffuse - Sn 5m 1Q auto PNP/NPN

Dimensions. Model Number. Electrical connection emitter. Features. Electrical connection receiver. Product information. Pinout OBE12M-R100-S2EP-IO-V31

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

QS30 Series. Diffuse-Mode Laser Sensors. QS30 Laser Models. Supply Voltage. 2 m (6.5') 5-wire Cable. Integral 5-pin Euro-style QD.

Q5X Laser Triangulation Sensor with Background Suppression

PHOTOSWITCH Distance Measurement Sensor

Basic Series 18 mm Diameter Cylindrical Sensors

Line Laser Module LLM01. User Manual. JENOPTIK Group.

Operating manual. GTL - Configuration tool. Please keep the manual for future use.

Operating instructions Electronic digital pressure sensor EPS25-XXXX-1001

Q08 Series Opposed-Mode Sensors

ivu TG Gen2 Image Sensor with Integrated Display

BX80 series High resolution cubic housing area sensor

Installation Guide. O2Vxxx / / 2015

Brief instructions Starter set BasicController BasicRelay BasicDisplay EC / / 2011

Operating instructions Pressure sensor. PN70xx / / 2010

Device manual Diagnostic electronics with PROFINET-IO interface for vibration sensors VSE150

LZR - U920/-U921. LASER MEASUREMENT DEVICE with bidirectional bus communication. User s Guide for product version 0500 and more

SF10 SF10. Features: The SF10 laser altimeter is ideal for automated landings and precision hovering.

Brief instructions Mobile 3D sensor O3M150 O3M151 O3M160 O3M /00 03/2016

Operating instructions Binary level sensor LMTx0x LMTx1x LMTx2x

Operating Manual FPGA-based High-Speed Micro-PLC

F3ET Lightcurtain in robust aluminium housing

WORLD BEAM QS18LLP Series

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

KEZ-c2TR28V12XIR HD-TVI 1080p Varifocal IP66 Super Beam IR True WDR Turret Cameras with OSD, CVBS Output and UTC Control

Assembly and Operating Instructions. M2 module for BDC-i440 control units

Operating instructions Pressure sensor. PE30xx / / 2010

Operating instructions RFID read/write head with IO-Link DTIxxx

T4HD: Installation Supplement R8.1.13

KEZ-c1TR28V12XIR HD-TVI 720p Low Light Varifocal IP66 EXIR Turret Cameras with OSD, CVBS Test Output and UTC Control

MANUAL VAA-2E2A-G12-SAJ/EA2L Original Instructions Version 1.0

Transcription:

Operating instructions Optical distance sensor OID0x 800005 / 00 08 / 01

Contents 1 Preliminary note... 1.1 Symbols used... 1. Warning signs used... Safety instructions... Functions and features...5.1 Applications...5 Installation...5.1 Installation conditions...5 5 Electrical connection...5 6 Setting / Operation...6 7 IO-Link...7 7.1 General information...7 7. Device-specific information...7 7. Parameter setting tools...7 8 Maintenance, repair and disposal...7

1 Preliminary note 1.1 Symbols used Instruction > Reaction, result [ ] Designation of pushbuttons, buttons or indications Cross-reference Important note Non-compliance can result in malfunctions or interference. Information Supplementary note. 1. Warning signs used WARNING Warning of serious personal injury. Death or serious irreversible injuries may result. Safety instructions Please read this document prior to set-up of the unit. Ensure that the product is suitable for your application without any restrictions. Improper or non-intended use may lead to malfunctions of the unit or to unwanted effects in your application. That is why installation, electrical connection, set-up, operation and maintenance of the unit must only be carried out by qualified personnel authorised by the machine operator. In case of malfunction of the unit please contact the manufacturer. If the unit is tampered with and/or modified, any liability and warranty is excluded. The unit conforms to the standard EN 61000-6-. The unit may cause radio interference in domestic areas. If interference occurs, the user must take appropriate remedial actions.

WARNING Visible laser light; laser protection class. Use of controls or adjustments other than those specified herein may result in hazardous radiation exposure. Damage to the retina is possible. Do not stare into the laser beam! Apply the enclosed labels (laser warning) in the immediate vicinity of the unit. Adhere to the caution and warning notes on the product label. Use the enclosed label for the power supply cable. Label for supply cable D-518 Essen Product label AVOID EXPOSURE LASER RADIATION EMITTED FROM THIS APERTURE CAUTION LASER RADIATION CLASS LASER PRODUCT 1 CFR PART 100, IEC 6085-1:007 DO NOT STARE INTO BEAM max. POWER.0mW PULSE 1.ns, λ = 650nm POWER OIDxx CLASS LASER PRODUCT www.ifm.com TS AA 101 OUT

Functions and features The unit is used as an optical distance sensor..1 Applications The optical distance sensor measures distances between 0.0 and m. It has a background suppression of up to 0 m. The switching outputs are complimentary. The distance between the sensor and the background must be limited to max. 0 m by the customer. Otherwise the measured value may be ambiguous..1 Installation conditions Installation.1 Installation conditions Install the unit so that the object to be detected is within a measuring range of 0.0... m. Any object between the set switch point and a distance of 0 m from the sensor is suppressed. Reflecting objects in the direct beam path of the sensor - also in the range > 0 m are to be avoided by the customer. Otherwise the measured values may be ambiguous. 5 Electrical connection The unit must be connected by a qualified electrician. The national and international regulations for the installation of electrical equipment must be adhered to. Ensure voltage supply according to EN 50178, SELV, PELV. Disconnect power. Connect the unit as follows: DC PNP 1 : OUT : OUT1 1 BN WH BK BU L+ L : OUT1 = normally open / IO-Link : OUT = normally closed 5

DC NPN 1 : OUT : OUT1 1 WH Core colours of ifm sockets: 1 = BN (brown), = WH (white), = BU (blue), = BK (black) 6 Setting / Operation BN BK BU L+ L : OUT1 = normally open / IO-Link : OUT = normally closed 1 OUT 100 ma 10...0 V DC PNP PNP 100 ma OUT1 5 1: Setting marks : Yellow LED: Set1 value reached, output = ON : Locking ring : Setting ring (manually adjustable after unlocking) 5: Green LED: supply voltage O.K. To obtain the setting accuracy: Set the ring to the maximum value, then set the requested value. After mounting, wiring and programming check whether the unit operates correctly. Lifetime of a laser diode: 50,000 hours 6

7 IO-Link 7.1 General information This unit has an IO-Link communication interface which requires an IO-Linkcapable module (IO-Link master) for operation. The IO-Link interface enables direct access to the sensor values and parameters and provides the possibility to set the parameters of the unit during operation. In addition communication is possible via a point-to-point connection with a USB adapter cable. You will find more detailed information about IO-Link at www.ifm.com/uk/io-link. 7. Device-specific information You will find the IODDs necessary for the configuration of the IO-Link unit and detailed information about sensor values, diagnostic information and parameters in the overview table at www.ifm.com/uk/io-link. 7. Parameter setting tools You will find all necessary information about the required IO-Link hardware and software (e.g. ifm LINERECORDER SENSOR ZGS10) at www.ifm.com/uk/io-link. 8 Maintenance, repair and disposal Faulty sensors must only be repaired by the manufacturer. Keep the front lens of the sensor free from soiling. After use dispose of the unit in an environmentally friendly way in accordance with the applicable national regulations. Do not try to open the module enclosure. There are no user-serviceable components inside. Technical data and further information at www.ifm.com 7