Input/Output Module (IOM) Series Controllers Catalog Page Code No. LIT Issued December 2017

Similar documents
Input/Output Module (IOM) Series Controllers Catalog Page Code No. LIT Issued June 2018

Input/Output Module (IOM) Series Catalog Page

FX-PCX Expansion Input/Output Modules Catalog Page Code No. LIT Issued April 17, 2015

Field Equipment Controller (FEC) Series Catalog Page Code No. LIT Issued June 2018

Advanced Application Field Equipment Controller (FAC) Catalog Page

FX-PCA Advanced Application Programmable Controller Catalog Page

FEC - FAC. Metasys controllers. Complex BAS Programmable controllers. Catalog Page. Field Equipment Controllers

PEAK TM. PEAK TM controllers. Mid-Market BAS Smart equipment controllers. HVAC/R controllers

VMA Programmable VAV Box Controllers Catalog Page Code No. LIT Issued February 2018

VMA Programmable VAV Box Controllers Catalog Page

FX-PC Series Programmable Controllers and Related Products Product Bulletin

PEAK TM. SMART Equipment Controllers. Product bulletin

Network Control Engine Catalog Page

FX Input/Output (I/O) Modules XM07 and XM14

Smart Equipment Controls (SEC)

Metasys System Field Equipment Controllers and Related Products Product Bulletin

FX-PC Series Programmable Controllers and Related Products Product Bulletin

Metasys System Field Equipment Controllers and Related Products Product Bulletin

FEC26 Field Equipment Controller

Features Communication Using Commonly Accepted IT Standards, Including Web Services, at the Automation and Enterprise Level Web-Based User Interface

FX-DIS1710 Local Controller Display Installation Instructions Part No , Rev. B Issued April 2016

Application and Data Server (ADS) Lite-A System Catalog Page

Network Integration Engine (NIEx9) for Third-Party Integrations Catalog Page

IOM47 Input/Output Module Installation Instructions Part No , Rev. K Issued April 2016

FXVMA Variable Air Volume (VAV) Box Controller

FEC26 Extended Temperature Field Equipment Controller

FEC25 Field Equipment Controller Installation Instructions Part No , Rev. A Issued April 2016

IOM47 Input/Output Module Installation Instructions Part No , Rev. L Issued November 2017

FAC Advanced Application Field Equipment Controller Installation Instructions

FX-BTCVT Bluetooth Commissioning Converter Installation Instructions

Network Control Engine

LN Series Remote Input/Output (I/O) Modules

Verasys System Product Bulletin

FEC26 Field Equipment Controllers Installation Instructions MS-FEC2611-x, MS-FEC2621-x, MS-FEC2611-xET

FEC1611 and FEC1621 Field Equipment Controller Installation Instructions

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

Onboard Inputs and Outputs. Remote User Interface. Integral LCD User Interface

NCE25 Installation Instructions MS-NCE25xx-x

LX Series Remote Input/Output (I/O) Controller

Network Automation Engine Catalog Page MS-NAE35xx-x, MS-NAE45xx-x, MS-NAE55xx-x, NAE Software Release 8.1 Issued February 2017

TC-9102 Terminal Controller

VMA1610 and VMA1620 Variable Air Volume Controllers Installation Instructions

NIEx9. Metasys. BAS network automation Supervisory controllers. Network Integration Engine

Medium User Interface (MUI) Version 3

FX-PCX17 and FX-PCX27 Expansion Input/Output Module Installation Instructions

NIE59 Network Integration Engine Figure 1: NIE59 Network Integration Engine

FX06 Field Controller

Network Automation Engine Catalog Page MS-NAE35xx-x, MS-NAE45xx-x, MS-NAE55xx-x, MS-NAE551S-2, NAE Software Release 9.0 Issued August 2017

FX-PCG26 General Purpose Programmable Controller Installation Instructions

FX-PCA Advanced Application Programmable Controller Installation Instructions

FX-PCA3611 Advanced Application Programmable Controller Installation Instructions

IOM2721 Input/Output Module Installation Instructions MS-IOM2721

Modular Room Control (MRC) Series Expansion Board

NAE. Metasys. BAS network automation Supervisory controllers. Network Automation Engine

LX Series Free Programmable LX-PRG6x0-11 Controllers and LX Series Input/Output (I/O) Extension Modules

Wireless Metasys System

FX14 Field Controller

WNC1800/ZFR182x Pro Series Wireless Field Bus System

ZFR1800 Series Wireless Field Bus System

Network Automation Engine

NAE55/NIE55 Installation Instructions MS-NAE55xx-3, MS-NIE55xx-3, MS-NAE5510-2U

Network Integration Engine (NIEx9) for Third-Party Integrations Product Bulletin

Buy American Facility Explorer Products Facility Explorer Product Management Authorized Building Controls Specialists (ABCS)

XT-9100 Technical Bulletin

Lab and Central Plant Controller

FX-DIS Local Controller Display Technical Bulletin

Specification Sheet For electronically commutated motors

LN Series Free Programmable LN-PRG6x0-12 Controllers and LN Series Input/Output (I/O) Extension Modules

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

Metasys N1 Network Integration

Datasheet. ECB-PTU Series. 1/14. BACnet B-ASC Powered Terminal Unit Programmable Controllers. Overview

Andover ContinuumTM. b3850 Series Terminal Controllers

BACnet. b3867 Terminal Controllers

Extended Digital Controller

Variable Air Volume Modular Assembly (VMA) 1400 Series

FX40 Supervisory Controller

Andover ContinuumTM b3865/866 VAV Controllers with Built-in Actuator

DX-9100 Digital Controller, Version 2

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator

TX-I/O Product Range. Description. Technical Specification Sheet Document No February 20, 2018

Field selectable application type and room module series, via dip-switches on controller

TX-I/O Product Range. Description. Technical Specification Sheet Document No July 18, 2013

WNC1800/ZFR182x Pro Series Wireless Field Bus System Quick Reference Guide

Andover ContinuumTM Infinet II

BACnet B-ASC Powered Terminal Unit Programmable Controllers. Overview

MS/TP Communications Bus Technical Bulletin Code No. LIT Software Release 9.0 Issued December 2017

VMA1615/1626/1628/1630 VAV Controllers Installation Instructions

BACnet. b3810 Series Local Controllers

ZFR1800 Series Wireless Field Bus System

N2 Dialer Module. Features and Benefits

8 channel universal input and 4 channel Form C digital output

Network Integration Engine

Commercial Comfort System (CCS)

FP-PS-4. Features. Installation

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

NIE39/NIE49 Installation Instructions MS-NIE39xx-2, MS-NIE49xx-2

Network Integration Engine Product Bulletin

LCS85 Turnkey User's Guide Part No , Rev. F Software Release 6.1 Issued June 17, 2013 Supersedes January 30, 2011

TX-I/O Product Range. Features. Description. Technical Specification Sheet Document No January 24, 2007

NS Series Network Sensors

Transcription:

Input/Output Module () Series Controllers Catalog Page Code No. LIT-190039 Issued December 017 Refer to the QuickLIT website for the most up-to-date version of this document. The Input/Output Module () Series expansion I/O modules have integral RS-5 MS/TP communications and integrate into the web-based Metasys system. s can serve in one of two capacities, depending on where they are installed in the Metasys system. When installed on the Sensor/Actuator (SA) Bus of an Advanced Application Field Equipment Controller (FAC), Field Equipment Controller (FEC), or VAV Modular Assembly (VMA) controller, the expands the point count of these controllers. When installed on the Field Controller (FC) Bus, s can be used as I/O point multiplexors to support monitoring and control from an Network Automation Engine (NAE) or Network Control Engine (NCE). The point multiplexor can also be useful for sharing points between other field controllers on the FC Bus using peer-to-peer connectivity. Note: At CCT Release 10.1 and later, FACs, FECs, and VMAs can communicate by using either the BACnet or the N field bus networking protocol. The operation of the Input/Output Module is not affected by the selection of the BACnet or the N protocol in the host controller. All expansion modules are BACnet Testing Laboratory (BTL) listed. Refer to the Series Technical Specifications Table for details. Important: Important: You cannot purchase a similar third-party device and install it in a UL/ULC Listed smoke control system. Doing so voids the UL/ULC Smoke Control Listing. Third-party devices must be provided and labeled by the factory as described in the UL/ULC Smoke Control Listing. Only those Johnson Controls products identified for use in smoke control applications have been tested and listed by UL for use in a Metasys System UL 6 9th Edition UUKL/ORD-C100-13 UUKLC Smoke Control System. Installation of a product that is not UL/ULC Listed and labeled for this application prevents the entire system from being UL/ULC Listed for smoke control. Refer to the Metasys System Field Equipment Controllers and Related Products Product Bulletin (LIT-10110) for product application details. If the product fails to operate within its specifications, replace the product. For a replacement product, contact the nearest Johnson Controls representative. Input/Output Modules () Features Ability to Reside on the Field Controller (FC) Bus or Sensor/Actuator (SA) Bus Provides application flexibility. Standard BACnet Protocol Provides interoperability with other Building Automation System (BAS) products that use the widely accepted BACnet standard. BACnet Testing Laboratories (BTL) Listed Ensures interoperability with other BTL-listed devices. BTL is a third-party agency, which validates that BAS vendor products meet the BACnet industry-standard protocol. Standard Hardware and Software Platform Uses a common hardware design throughout the family line to support standardized wiring practices and installation workflows. Also uses a common software design to support use of a single tool for control applications, commissioning, and troubleshooting to minimize technical training. Universal Inputs, Configurable Outputs, and Point Expansion Modules Allows multiple signal options to provide input/output flexibility. Optional Local User Interface Display Allows convenient monitoring and adjusting capabilities at the local device. 3-bit Microprocessor Ensures optimum performance and meets industry specifications. BACnet Automatic Discovery Supports easy controller integration into a Metasys BAS. Pluggable Communications Bus and Supply Power Terminal Blocks Expedites installation and troubleshooting. Wireless Connectivity through the ZFR100 Series or the WNC100/ZFR1x Pro Series Wireless Field Bus Systems in MS/TP Controllers Enables wireless mesh connectivity to supervisory controllers, facilitating easy initial location and relocation. Bluetooth Wireless Commissioning Provides an easy-to-use connection to the configuration and commissioning tool. End-of-Line (EOL) Switch in MS/TP Field Controllers Enables field controllers to be terminating devices on the communications bus. Input/Output Module () Series Controllers Catalog Page 1

Table 1: Series Model Information (Including Point Type Counts) Communication Protocol Engines Modular Jacks Point Types Universal Input (UI) Signals Accepted Analog Input, Voltage Mode, Analog Input, Current Mode, 0 ma Analog Input, Resistive Mode, 0 kohm, RTD (1k NI [Johnson Controls], 1k PT, A99B SI), NTC (10k Type L,.5k Type ) Binary Input, Dry Contact Maintained Mode 1711 711 BACnet MS/TP 71 3711 371 3731 711 73 1 373 1 3733 1 All Model types. Some NIE models support MS/TP and N devices. Refer to the Network Engines Product Bulletin (LIT-10113) for details. 6-pin SA Bus Modular Port supports one communicating sensor. Or you can wire up to four communicating sensors to the SA Bus Terminal Block. They cannot be used at the same time. 6-pin FC Bus for tool support 6 Binary Input (BI) Dry Contact Maintained Mode 16 16 Pulse Counter/Accumulator Mode (High Speed), 100 Hz Analog Output (AO) Analog Output, Voltage Mode, Analog Output, Current Mode, 0 ma Binary Output (BO) VAC Triac 3 Universal Output (UO) Analog Output, Voltage Mode, Binary Output Mode, VAC/DC Field-Effect Transistor (FET) Analog Output, Current Mode, 0 ma Configurable Output (CO) Analog Output, Voltage Mode, Binary Output Mode, VAC Triac Relay Output (RO) 10/0 VAC (-0 models only) Relay Output (RO) 0 VAC (- models only) 1 This model is currently only available in Asia. Contact your local Johnson Controls representative for more information. The BOs on the 3731-0A and MS-3733-0 models require an external low-voltage power source. Table : Series Ordering Information Product Code Number MS-1711-0 MS-711-0 MS-711- MS-71-0 MS-73-0 1 -Point with BI, FC Bus and SA Bus Support 6-Point with UI, UO, BO, FC Bus, and SA Bus Support. Relays are rated for 10/0 VAC. 6-Point with UI, UO, BO, FC Bus, and SA Bus Support. Relays are rated for 0 VAC. 10-Point with UI, AO, FC Bus, and SA Bus Support 10-Point with UI, AO, FC Bus, and SA Bus Support UL and cul (Canada) CE Marked Input/Output Module () Series Controllers Catalog Page

Table : Series Ordering Information Product Code Number MS-3711-0 MS-3711- MS-371-0 MS-373-0 1 MS-3731-0 MS-3731-0A 1 MS-3733-0 1 MS-711-0 1-Point with UI, UO, BO, FC Bus, and SA Bus Support. Relays are rated for 10/0 VAC. 1-Point with UI, UO, BO, FC Bus, and SA Bus Support. Relays are rated for 0 VAC. 16-Point with 16 BI, FC Bus, and SA Bus Support 16-Point with 16 BI, FC Bus, and SA Bus Support 16-Point with BI, BO, FC Bus, and SA Bus Support 16-Point with BI, BO, FC Bus, and SA Bus Support Binary Outputs (BOs) on MS-3733 controllers do not supply power for the outputs; the BOs require external low-voltage (<30 VAC) power sources. 16-Point with BI, BO, FC Bus, and SA Bus Support Binary Outputs (BOs) on MS-3731-0A controllers do not supply power for the outputs; the BOs require external low-voltage (<30 VAC) power sources. 17-Point with 6 UI, BI, 3 BO, AO, CO, FC and SA Bus Support UL and cul (Canada) CE Marked 1 This model is currently only available in Asia. Contact your local Johnson Controls representative for more information. Table 3: Series for Smoke Control Ordering Information Product Code Number 1, MS-1710-0U MS-1711-0U MS-710-0U MS-711-0U MS-3710-0U MS-3711-0U MS-IOU710-0U MS-711-0U -Point with BI; VAC; FC Bus and SA Bus Support -Point with BI; VAC; FC Bus and SA Bus Support 6-Point with UI, UO, BO; VAC; FC Bus and SA Bus Support 6-Point with UI, UO, BO; VAC; FC Bus and SA Bus Support 1-Point with UI, UO, BO; VAC; FC Bus and SA Bus Support 1-Point with UI, UO, BO; VAC; FC Bus and SA Bus Support 17-Point with 6 UI, BI, 3 BO, AO, CO; VAC; FC Bus and SA Bus Support with Mounting Base 17-Point with 6 UI, BI, 3 BO, AO, CO; VAC; FC Bus and SA Bus Support with Mounting Base 1 These devices are UL/ULC 6 Listed, File S977, 9th Edition UUKL/ORD-C100-13 UUKLC Smoke Control System. These devices must be ordered in a Smoke Control UUKL listing. All field controllers in a smoke control system must be mounted in Johnson Controls custom or standard UL 6 panels or in panels that are ordered from Johnson Controls. If these field controllers are used with panels that are not supplied by Johnson Controls, they are not compliant with the UL 6 9th Edition UUKL/ORD-C100-13 UUKLC Smoke Control System listing. Input/Output Module () Series Controllers Catalog Page 3

Accessories Table : Accessories Product Code Number TL-MAP110-0P TL-MAP110-0S TL-MAP110-0PE TL-MAP110-0PA MS-BTCVT-1 MS-BTCVTCBL-700 ZFR100 Series Wireless Field Bus System ZFR-USBHA-0 Y6T15-0 Y65A13-0 Y65T-0 Y65T31-0 AP-TBKSA-0 AP-TBKFC-0 AP-TBK3PW-0 TL-BRTRP-0 Portable MAP Gateway for US/Canada - includes MAP Gateway, RJ-1 cable, bumper guard, and lanyard Stationary MAP Gateway for US/Canada - includes MAP Gateway, field bus adapter, mounting bracket, and AC power supply. (Adapters for the power supply may vary by country.) Portable MAP Gateway - for Europe (All EU Countries); Middle East (UAE and Qatar) Portable MAP Gateway - for Asia (China, Japan, Australia, New Zealand, India, Hong Kong, Singapore, Thailand) Wireless Commissioning Converter with Bluetooth Technology Cable Replacement Set for the MS-BTCVT-1 or the NS-ATV7003-0; Includes One 5 ft (1.5 m) Retractable Cable This system is used for installations that only support BACnet MS/TP. Refer to the WNC100/ZFR1x Pro Series Wireless Field Bus System Product Bulletin (LIT-10130) for a list of available products. ZFR USB Dongle provides a wireless connection through CCT to allow wireless commissioning of the wirelessly enabled FEC, Advanced Application Field Equipment Controller (FAC),, and VMA16 controllers. Also allows use of the ZFR Checkout Tool (ZCT) in CCT. Transformer, 10/0/0 VAC Primary to VAC Secondary, 9 VA, Foot Mount, 30 in. Primary Leads and 30 in. Secondary Leads, Class Transformer, 10 VAC Primary to VAC Secondary, 0 VA, Foot Mount (Y65AS), in. Primary Leads and 30 in. Secondary Leads, Class Transformer, 10/0/0 VAC Primary to VAC Secondary, 0 VA, Hub Mount (Y65SP+), in. Primary Leads and Secondary Screw Terminals, Class Transformer, 10/0/0 VAC Primary to VAC Secondary, 0 VA, Foot Mount (Y65AR+), in. Primary Leads and Secondary Screw Terminals, Class Replacement MS/TP SA Bus Terminal, -Position Connector, Brown (Bulk Pack of 10) Replacement MS/TP FC Bus Terminal, -Position Connector (Bulk Pack of 10) Replacement Power Terminal, 3-Position Connector, Gray (Bulk Pack of 10) Portable BACnet/IP to MS/TP Router Input/Output Module () Series Controllers Catalog Page

Series Technical Specifications Table 5: Series Product Code Numbers MS-1711-0: -Point with BI, FC Bus and SA Bus Support MS-711-0: 6-Point with UI, UO, BO, FC Bus, and SA Bus Support. Relays are rated for 10/0 VAC MS-711-: 6-Point with UI, UO, BO, FC Bus, and SA Bus Support. Relays are rated for 0 VAC. MS-71-0: 10-Point with UI, AO, FC Bus, and SA Bus Support MS-73-0 1 : 10-Point with UI, AO, FC Bus, and SA Bus Support MS-3711-0: 1-Point with UI, UO, BO, FC Bus, and SA Bus Support. Relays are rated for 10/0 VAC MS-3711-: 1-Point with UI, UO, BO, FC Bus, and SA Bus Support. Relays are rated for 0 VAC MS-371-0: 16-Point with 16 BI, FC Bus, and SA Bus Support MS-373-0 1 : 16-Point with 16 BI, FC Bus, and SA Bus Support MS-3731-0: 16-Point with BI, BO, FC Bus, and SA Bus Support MS-3731-0A 1 : 16-Point with BI, BO, FC Bus, and SA Bus Support MS-3733-0 1 : 16-Point with BI, BO, FC Bus, and SA Bus Support MS-711-0: 17-Point with 6 UI, BI, 3 BO, AO, CO, FC and SA Bus Support Smoke Control Models: MS-1710-0U: -Point with BI, FC Bus and SA Bus Support MS-1711-0U: -Point with BI, FC Bus and SA Bus Support MS-710-0U: 6-Point with UI, UO, BO, FC Bus, and SA Bus Support MS-711-0U: 6-Point with UI, UO, BO, FC Bus, and SA Bus Support MS-3710-0U: 1-Point with UI, UO, BO, FC Bus, and SA Bus Support MS-3711-0U: 1-Point with UI, UO, BO, FC Bus, and SA Bus Support MS-IOU710-0U: 17-Point with 6 UI, BI, 3 BO, AO, CO, FC Bus and SA Bus Support with Mounting MS-711-0U: 17-Point with 6 UI, BI, 3 BO, AO, CO, FC Bus and SA Bus Support with Mounting Supply Voltage Power Consumption VAC (nominal, 0 VAC minimum/30 VAC maximum), 50/60 Hz, Power Supply Class (North America), Safety Extra-Low Voltage (SELV) Europe 1 VA maximum Note: VA ratings do not include any power supplied to the peripheral devices connected to Binary Outputs (BOs) or Configurable Outputs (COs), which can consume up to 1 VA for each BO or CO, for a possible total consumption of an additional VA (maximum), depending on the model. Ambient Conditions Operating: 0 to 50 C (3 to 1 F); 10 to 90% RH noncondensing Storage: -0 to 0 C (-0 to 176 F); 5 to 95% RH noncondensing Addressing DIP switch set; valid field controller device addresses 17 (Device addresses 0 3 and 1 55 are reserved and not valid addresses). Communications Bus BACnet MS/TP, RS-5 3-wire FC Bus between the supervisory controller and field devices -wire SA Bus between field controller, network sensors, and other sensor/actuator devices. Includes a lead source 15 VDC supply power (from field controller) to bus devices. Processor MS-1711-0, MS-711-0, MS-711-, MS-71-0, MS-3711-0, MS-3711-, MS-3731-0, MS-3731-0A 1, and MS-711-0: HS/166xR Renesas 3-bit microcontroller MS-73-0 1, MS-373-0 1, MS-3733-0 1 : R631 3-bit Renesas microcontroller Memory MS-1711-0, MS-711-0, MS-711-, MS-71-0, MS-3711-0, MS-3711-, MS-3731-0, MS-3731-0A 1, and MS-711-0: 51 KB Flash Memory and 1 KB RAM MS-73-0 1, MS-373-0 1, and MS-3733-0 1 : MB External Serial Flash Memory Input/Output Module () Series Controllers Catalog Page 5

Table 5: Series Input and Output Capabilities MS-1711-0: - Binary Inputs: Defined as Dry Contact Maintained or Pulse Counter/ Accumulator Mode MS-711-x: - Universal Inputs: Defined as, 0 ma, 0 600k ohm, or Binary Dry Contact - Universal Outputs: Analog Output: Voltage Mode, 0-10 VDC; Binary Output Mode: VAC/DC FET; Analog Output: Current Mode, -0 ma - Relay Outputs: (Single-Pole, Double-Throw) UL 916 (-0 model only): 1/ hp 10 VAC, 1/ hp 0 VAC; 360 VA Pilot Duty at 10/0 VAC (B300); 3 A Non-inductive -0 VAC EN 60730 (- model only): 6 () A N.O. or N.C. only, 0 VAC MS-71-0 and MS-73-0 1 : - Universal Inputs: Defined as, 0 ma, 0 600k ohm, or Binary Dry Contact - Analog Outputs: Defined as or 0 ma MS-3711-x: - Universal Inputs: Defined as, 0 ma, 0 600k ohm, or Binary Dry Contact - Universal Outputs: Analog Output: Voltage Mode, 0-10 VDC; Binary Output Mode: VAC/DC FET; Analog Output: Current Mode, -0 ma - Relay Outputs: (Single-Pole, Double-Throw) UL 916 (-0 model only): 1/ hp 10 VAC, 1/ hp 0 VAC; 360 VA Pilot Duty at 10/0 VAC (B300); 3 A Non-inductive -0 VAC EN 60730 (- model only): 6 () A N.O. or N.C. only, 0 VAC MS-371-0 and MS-373-0 1 : 16 - Binary Inputs: Defined as Dry Contact Maintained or Pulse Counter/Accumulator Mode MS-3731-0, MS-3731-0A 1, and MS-3733-0 1 : - Binary Inputs: Defined as Dry Contact Maintained or Pulse Counter/Accumulator Mode - Binary Outputs: Defined as VAC Triac (Require external low-voltage power source) Note: Binary Outputs (BOs) on MS-3731-0A and MS-3733-0 models do not supply power for the outputs; the BOs require external low-voltage (< 30 VAC) power sources. MS-711-0: 6 - Universal Inputs: Defined as, 0 ma, 0 600k ohm, or Binary Dry Contact - Binary Inputs: Defined as Dry Contact Maintained or Pulse/Counter Accumulator Mode 3 - Binary Outputs: Defined as VAC Triac (selectable internal or external source power) - Configurable Outputs: Defined as or VAC Triac BO - Analog Outputs: Defined as or 0 ma Analog Input/Analog Output Resolution and Accuracy MS-1711-0, MS-711-0, MS-711-, MS-71-0, MS-3711-0, MS-3711-, MS-3731-0, MS-3731-0A 1, and MS-711-0: Analog Input: 16-bit resolution Analog Output: 16-bit resolution and ±00 mv in applications MS-73-0 1, MS-373-0 1, and MS-3733-0 1 : Analog Input: 15-bit resolution Analog Output: ±00 mv in applications Input/Output Module () Series Controllers Catalog Page 6

Table 5: Series Terminations MS-1711-0, MS-711-0, MS-711-, MS-71-0, MS-3711-0, MS-3711-, MS-3731-0, MS-3731-0A 1, and MS-711-0: Input/Output: Fixed Screw Terminal Blocks SA/FC Bus and Supply Power: -wire and 3-wire Pluggable Screw Terminal Blocks SA/FC Bus Port: RJ-1 6-Pin Modular Jacks MS-73-0 1, MS-373-0 1, and MS-3733-0 1 : Input/Output: Fixed Screw Terminal Blocks Note: There are no labels on I/O terminal blocks. The labels are above/below the terminal blocks on the packaging. SA/FC Bus and Supply Power: -wire and 3-wire Pluggable Screw Terminal Blocks Mounting Housing Dimensions (Height x Width x Depth) Horizontal on single 35 mm DIN rail mount (preferred), or screw mount on flat surface with three integral mounting clips on controller Enclosure material: ABS and polycarbonate UL9 5VB; self-extinguishing, Plenum-rated protection class: IP0 (IEC59) MS-1711 and MS-711 Models: 150 x 10 x 53 mm (5-7/ x -3/ x -1/ in.) including terminals and mounting clips MS-71-0, MS-73-0 1, MS-371-0, MS-373-0 1, MS-3731-0, and MS-3733-0 1 models: 150 x 16 x 53 mm (5-7/ x 6-7/16 x -1/ in.) including terminals and mounting clips MS-3711-0 and MS-711-0 Models: 150 x 190 x 53 mm (5-7/ x 7-1/ x -1/ in.) including terminals and mounting clips Note: Mounting space for all field controllers requires an additional 50 mm ( in.) space on top, bottom, and front face of controller for easy cover removal, ventilation, and wire terminations. Weight Compliance 0.5 kg (1.1 lb) maximum United States: UL Listed, File E10701, CCN PAZ, UL 916, Energy Management Equipment; UL/ULC 6 Listed, File S977, 9th Edition UUKL/ORD-C100-13 UUKLC Smoke Control System (models with U product code suffix only); FCC Compliant to CFR7, Part 15, Subpart B, Class A Note: Except MS-711- and MS-3711- Canada: UL Listed, File E10701, CCN PAZ7, CAN/CSA C. No. 05, Signal Equipment; UL/ULC 6 Listed, File S977, 9th Edition UUKL/ORD-C100-13 UUKLC Smoke Control System (models with U product code suffix only); UL/ULC 6 Listed, File S977, 9th Edition UUKL/ORD-C100-13 UUKLC Smoke Control System (models with U product code suffix only); Industry Canada Compliant, ICES-003 Note: Except MS-711- and MS-3711- Europe: CE Mark Johnson Controls declares that this product is in compliance with the essential requirements and other relevant provisions of the EMC Directive. Declared as Independently Mounted, Intended for Panel Mounting, Operating Control Type 1.B, kv rated impulse voltage, 100.7 C ball pressure test. Note: Except MS-711-0 and MS-3711-0 Australia and New Zealand: RCM Mark, Australia/NZ Emissions Compliant Note: Except MS-711-0 and MS-3711-0 BACnet International: MS-1711-0, MS-711-0, MS-711-, MS-71-0, MS-3711-0, MS-3711-, MS-3731-0, MS-3731-0A 1, and MS-711-0: BACnet Testing Laboratories (BTL) Protocol Revision Listed BACnet Application Specific Controller (B-ASC) MS-73-0 1, MS-373-0 1, and MS-3733-0 1 : BACnet Testing Laboratories (BTL) Protocol Revision 1 Listed BACnet Smart Actuator (B-SA) 1 This model is currently only available in Asia. Contact your local Johnson Controls representative for more information. For more information, refer to the MS/TP Communications Bus Technical Bulletin (LIT-101103). The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls shall not be liable for damages resulting from misapplication or misuse of its products. Building Technologies & Solutions 507 E. Michigan Street, Milwaukee, WI 530 Metasys and Johnson Controls are registered trademarks of Johnson Controls. All other marks herein are the marks of their respective owners. 017 Johnson Controls Published in U.S.A. Input/Output Module () Series Controllers Catalog Page www.johnsoncontrols.com 7