Actuators AMV 655, 658 and 659 can be controlled by electronic controllers with 3-point output.

Similar documents
Actuators for three point control AMV 655 without safety function AMV 658 SU, AMV 658 SD with safety function (spring up/down)

Actuators AME 655, 658 and 659 can be controlled by electronic controllers with modulating or 3-point control output.

Actuators for modulating & 3-point control

AME 658 SU/ SD with safety function Motorized actuators for AB-QM valves

Actuators for modulating control AME 55, AME 56

Electrical actuator AME 855

Actuators for modulating control AME 13SU, AME 23SU - safety function (spring up)

Modulating controlled actuators AME 10, AME 20, AME 30 AME 13, AME 23, AME 33 - with DIN EN certified safety function (spring down)

Modulating controlled actuator AME 11

24V, Motorized Actuators

Electrical Actuators

Products no longer available

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

Electrical Actuators

Electrical Actuators

Products no longer available

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

Electromotoric actuators

Electromotive actuators for combi valves

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

ML7421A,B Electric Linear Valve Actuators

Non-communicating room controllers

Overview of types. Technical data

ASI Systems ML5720A Series

Technical data sheet. Technical data

Technical data sheets

ASI Systems ML5740A Series

NovoCon S Digital/Hybrid - High Accuracy Actuator

Electromotoric actuator

B. AVM321S/AVM322S: 1000N Actuator with analog SUT positioner

Electric Actuators Type 5824 (without fail-safe action) Type 5825 (with fail-safe action)

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electromotoric actuators

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

SAX.. ACVATIX Electromotive actuators for valves. with a 20 mm stroke

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Non-communicating room controllers

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

Room Temperature Controller

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manuelle Auslösung der Adaption durch Drücken der Taste «Adaption» oder mit dem PC-Tool

AVM 321, 322: Valve actuator

Room controller STRA-17

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency. Draft

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

Immersion Temperature Sensors

Electromotoric actuators

9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)

Power consumption In operation At rest For wire sizing

Electrical actuators

Actuator ABNM A5 LOG/LIN for AB-QM, 0-10 V Proportional

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

Room Temperature Controllers

VA-7700 Series. Electric Valve Actuators. Product Bulletin

2-PORT SEAT VALVES PN16 WITH FLANGED CONNECTIONS STAZ-16, STBZ-16, STCZ-52 DATASHEET

Room Temperature Controller with 7-Day Time Switch, LCD and opt. Remote Temperature Sensor

s Spring return C / max C

M-Bus Central Unit. Use

Motorised actuator 0-10V EAC

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Data Sheet A200 Series Electric Actuators

Room Temperature Controller

TAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta

Electromotoric actuators

Functional data Factory settings Variable Setting Torque Inhibiting torque

Manual Control Unit GFC 16

MVE5xxR. Globe Valves Actuators with Emergency Fail Safe Function DESCRIPTION POWER SUPPLY [N] APPLICATION AND USE OPERATION

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

Operating instructions. Switching amplifier DN0210 DN / / 2015

Rotary actuators for ball valves

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview

Temperature controller Ducted systems

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

Manual Control Unit GFC 32

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

3-PORT SEAT VALVES PN16 WITH EXTERNALLY THREADED CONNECTIONS STAZ-16, STBZ-16, STCZ-53 DATASHEET

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical data. Safety notes. Product features

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Output signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power supply DC V, ±10%, 0.3 W

Status display unit with P-bus connection

Electric Actuators with Process Controllers

ECL Comfort V a.c. and 24 V a.c.

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

TA-MC Actuators. Actuators High performance proportional actuators

Output Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W

Use. Functions. OpenAir TM. Linear version, modulating, AC 24 V

Electromotoric actuators for stroke valves

Manual Simatek Control Unit GFC 32

Universal Controller

Power supply module, bus connection module

Temperature Controller

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Heating Circuit Controller

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

OP10. Pre-programmed, configurable controller for simple applications

Transcription:

Data sheet Actuators for three point control without safety function SU, SD with safety function (spring up/down) SD with EN certified safety function (spring down) Description Actuators can be used in combination with: - Valve types VFM, VFS (DN 65-00), VFG(S), VFU, VF (DN 00-50) and VL (DN 00). - Self-acting flow controller AHQM (DN 25-50), AFQM 6 and AFQM PN 25. Features: Manual operation either mechanical and/or electrical Position indication LED signalling Inverse function Selectable speed Pulse output signal (4, 5) Thermical and overload protection Precise regulation and fast response on -point signal (0,04s) Actuators are primarily designed to regulate valve in the respond to the demand of a controller in District Heating/cooling, Heating, Ventilating and Air conditioning systems. Actuators, 658 and 659 can be controlled by electronic controllers with -point output. Main data: Nominal voltage (AC or DC): - 24 V, 50 Hz/60 Hz - 20 V; 50 Hz/60 Hz Control input signal: point signal Force: 2000 N Stroke: 50 mm Speed (selectable): (4) or 6 s/mm Max. medium temperature: 200 C Please check power supply and power consumption prior connection! Ordering Actuator Picture Type SU SD SD * Not available yet Power supply (V) Code No. 24 082G440 20 082G44 24 082G446* 20 082G447* 24 082G444 20 082G445 24 082G452* 20 082G45* Accessories - Stem heater Type DN Code No. Stem heater for VFM valves Accessories - Adapter Type Adapter VFG(S), VFU Adapter 2 VFG(S), VFU Adapter VFG(S), AFQM 6, AFQM PN 25 65-25 065Z7020 50-250 065Z7022 Code No. 065B525 065B526 065B527 DEN-SMT/SI VD.LE.S.02 Danfoss 0/20

Data sheet Actuators for three point control /658/659 Technical data Actuator type SD SU SD Power supply V 24 or 20 ; +0 5 % ; AC or DC Power consumption VA 4,4 (24 V) 6, (20 V) 9,2 (24 V) 5,7 (20 V) Frequency Hz 50/60 Control input -point 9,2 (24 V) 5,7 (20 V) 9,2 (24 V) 5,7 (20 V) Closing force N 2000 2000 2000 *N/A Max. stroke mm 50 Speed (selectable) s/mm or 6 4 or 6 4 or 6 *N/A Max. medium temperature 200 (50 with extension piece for VFGS) Ambient temperature C 0 + 55 Storage and transport temperature 40 +70 (storing for days) Humidity 5-95% Protection class Grade of enclosure IP 54 Weight kg 5, 8,6 8,6 8,6 Safety function - Yes Yes Yes (EN) Spring return runtime s - 20 20 20 Manual operation Power failure response marking in accordance with the standards * Data not available yet Mechanical Stem remains in last position Electrical and mechanical Safety return function extracts Low Voltage Directive 2006/95/EEC EMC Directive 2004/08/EEC II Electrical and mechanical Safety return function retracts Electrical Safety return function extracts Low Voltage Directive 2006/95/EEC EMC Directive 2004/08/EEC Safety function according to EN 4597 Disposal The actuator must be dismantled and the elements sorted into various material groups before disposal. Before disassembly please contact Danfoss support for disassembly instructions. Commissioning Complete the mechanical and electrical installation (see instructions) and perform the necessary checks and tests: - Turn on the power - Set the appropriate control signal and check that the valve stem direction is correct for the application. The unit is now fully commissioned. 2 VD.LE.S.02 Danfoss 0/20 DEN-SMT/SI

Data sheet Actuators for three point control /658/659 Design. Manual operation knob 2. Function buttons. Service cover 4. Removable gland support 5. Position indication ring 6. Stem connector 7. Valve connector Installation Mechanical Please check what are allowed installation positions for the valve in combination. The actuator can be installed in all positions. Use M8/SW key (not supplied) to fit the actuator to the valve body. Allow for necessary clearance for maintenance purposes. To link valve and actuator stems use a 4mm Allen key (not supplied). The actuator has position indication rings which should be pushed together before el. connection; after self-stroking they indicate end positions of the stroke. Electrical Electrical connections can be accessed by removing the service cover. Four cable entries on removable gland support are provided for M 6,5 or M 20,5 cable glands. Note that in order to maintain the enclosure IP rating, appropriate cable glands must be used. DEN-SMT/SI VD.LE.S.02 Danfoss 0/20

Data sheet Actuators for three point control /658/659 Wiring Do not touch anything on the PCB! Do not remove the service cover before the power supply is fully switched off. Max. allowed current output on terminals 4 and 5 is 4 A. SN 0 V Neutral 24, 20 V AC/DC Power supply 4, 5 (AC) 4 5 2 2 output Input /659 SN 0 V Neutral, 24, 20 V AC/DC Power supply 4, 5 4 5 output 2 2 Input Recommended cross-sectional area of the wiring is.5 mm 2. 4 VD.LE.S.02 Danfoss 0/20 DEN-SMT/SI

Data sheet Actuators for three point control /658/659 LED signalling / actuator operating modes LED operating mode indicator The three-colour (green/yellow/red) LED function indicators are located on the actuator cover. They indicate different operating modes. RESET button (versions /659) Actuators /659 have external RESET button which is located on top cover of the actuator next to LED indicators. With this button you can enter or exit Stand-By mode (press once) See next paragraph for mode details. Operating modes Stand-By mode (versions /659) Press the RESET button to enter Stand-By mode. The actuator stops in current position and stops responding to any control signal. Red light is constantly lit. You can manually operate the actuator with mechanical handle (version /658) or control buttons (versions /659). This mode can be very useful during the commissioning of other equipment, or for service purposes. To exit Stand-By mode press the RESET button again. Positioning mode The actuator is operating automatically. The stem is extracting or retracting according to the control signal. When positioning is finished the actuator goes to Stationary mode. Stationary mode The actuator is operating without errors. Error mode Working temperature is too high - check the ambient temperature. Stroke is too short - check the connection with valve and valve operation or check if valve is blocked. LED indication for /658/659 LED Indication type Operating mode Actuator type Green Positioning mode - Actuator is retracting Yellow Positioning mode - Actuator is extracting Stationary mode - Actuator has reached upper end position (retracted stem) Stationary mode - Actuator has reached bottom end position (extracted stem) Flashing Stationary mode Red Stand - By mode Dark No indication Flashing Error Mode No power supply No control signal NOTE! LED signalling is a direct indicator of the signal from controller therefore lengths of LED indication can vary and sometimes even look like a short flash if the controlling signal is present for a very short period. Actuator type doesn t have constant power supply and operates only when the controller provides a signal. Therefore limited LED indication possibilities are available. DEN-SMT/SI VD.LE.S.02 Danfoss 0/20 5

Data sheet Actuators for three point control /658/659 DIP switch setting The actuator has a selection DIP switches (Fig. ) under the service cover. DIP: FAST/SLOW Speed selection - FAST position; (4) s/mm (see Tech. data) - SLOW position; 6 s/mm DIP2: / Direct or inverse acting selector (Fig. 2): - position; the actuator is direct acting to input signal. - position; the actuator is inverse acting to input signal. Fig. Fig. 2 Manual operation Mechanical and electrical operation are not allowed to be used at the same time! Actuator can be manually positioned and remains in selected position until it receives signal from the controller. Actuators can be manually positioned when in Stand-By mode or when there is no power supply (mechanically). Actuators can be manually positioned only in Stand-By mode. Actuator type Mechanical operation Electrical operation B A A B Mechanical manual operation Actuators /658 have a manual operation knob on the top of the housing which enables hand positioning of the actuator. Mechanical manual operation shall be only used when no power supply. Electrical manual operation Actuators /659 have two buttons on the top of the housing that are used for electrical manual positioning (up or down) if the actuator is in Stand-By mode. First press the RESET button until the actuator goes to Stand-By mode (red LED is lit). By pressing the upper button the stem will be extracted and by pressing the lower button will be retracted. 6 VD.LE.S.02 Danfoss 0/20 DEN-SMT/SI

Data sheet Actuators for three point control /658/659 Actuator valves combinations VFM 2 VF 2 (DN 00-50) VL 2 (DN 00) VFS 2 (DN 65-00) VF (DN 00-50) VL (DN 00) VFG(S) 2 + adapter: 065B525 (DN 5-65) 065B526 (DN 80-25) 065B527 (DN 50-250) VFU + adapter: 065B525 (DN 5-65) 065B526 (DN 80-25) VFG + adapter: 065B525 (DN 25-50) 065B526 (DN 65-25) AHQM (DN 25, 50) AFQM 6 + adapter 065B527 AFQM PN 6 (DN 65-25) AFQM PN 25 + adapter 065B527 DEN-SMT/SI VD.LE.S.02 Danfoss 0/20 7

Data sheet Actuators for three point control /658/659 Dimensions 9 69 5 Min. 450 86 8 VD.LE.S.02 Produced by Danfoss A/S 07/202