SIMOCODE 3UF Motor Management and Control Devices

Similar documents
SIRIUS Motor Management and Control Devices

Contact protection relay

Siemens AG SIMOCODE 3UF Motor Management and

Siemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY

Electronic timer CT-AHD.22

Electronic timer CT-ERD.12

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

MINI MCR-SL-UI-REL(-SP)

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

Siemens AG RA6 Fuseless Compact Starters. Catalog News LV 1 N April 2008 SIRIUS.

Thermistor motor protection relay CM-MSS.21

TM3AI4 module TM3-4 analog inputs

TM3TI4 module TM3-4 inputs temperature

Electronic timer CT-ERS.21

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

TM3TI4 module TM3-4 inputs temperature

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

TM3TI8T module TM3-8 inputs temperature

Thermistor motor protection relays CM-MSS.32 and CM-MSS.33

Monitoring Relays. 3UG Monitoring Relays for Electrical and Additional Measurements. Line monitoring 7/61. Overview

Thermistor motor protection relay CM-MSS.41

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

TM3TM3 module TM3-2 temperature inputs and 1 analog output

PHOENIX CONTACT Features

Load Feeders and Motor Starters for Use in the Control Cabinet

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

em4 Accessories Digital expansions

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

Electronic timer CT-ARS.11

JUMO Quantum PID100/PID200/PID300

IEC Power Control Overload Relays

IEC Power Control Overload Relays

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Bulletin 817 Thermistor Protection Relay

Controls Solid-State Switching Devices

Thermistor motor protection relay CM-MSS.41

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

AI531 Analog Input Module

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

General information. Display. Supply voltage

Solid-State Contactors

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

Thermistor motor protection relay CM-MSS.11

Industrial Controls Product Catalog 2017

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

MINI MCR-SL-PT100-UI(-SP)(-NC)

Thermistor motor protection relays CM-MSS.32 and CM-MSS.33

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

Messaging module CP-C MM

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact

Datasheet - SRB 402EM-24V

General information. Display. Supply voltage

Thermistor motor protection relay CM-MSS.31

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

DC562, digital input/output module,

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

AX522 Analog Input/Output Module

Electronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet

DC561, digital input/output module,

MINI MCR-SL-UI-2I(-SP)(-NC)

ABL1REM24025 regulated SMPS - single phase V input - 24 V output - 60 W

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

02/11/2015

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

General information. Display. Supply voltage. Input current. Encoder supply. Output current

ATS01N206RT soft starter for asynchronous motor - ATS01-6 A V

TU531, TU532 Terminal Unit

MINI-PS AC/10-15DC/8

General information. Display. Supply voltage. Input current. Encoder supply. Output current

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

General information. Display. Supply voltage. Input current

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

Datasheet - SRB 301LC/B-24V

Overvoltage Protection Devices

General information. Display. Supply voltage. Input current

AI561 Analog Input Module

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

Industrial Controls Product Catalog RA64 / 3RA65 up to 32 A for mounting rail, surface,

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W

DI572 Digital Input Module

Transcription:

Technical specifications General data applicable to the basic units, current measuring modules, current/voltage measuring modules, expansion modules, decoupling module and operator panel Permissible ambient temperature During operation C -25... +60 1) Storage and transport C -40... +80 2) Installation height above sea level m 2000 Permissible ambient temperature max. +50 C m 3000 (no protective separation) Permissible ambient temperature max. +40 C m 4000 (no protective separation) Degree of protection (acc. to IEC 60529) All components, IP20 (except for current measuring modules or current/voltage measuring modules for busbar connection, operator panel and door adapter) Current measuring modules or current/voltage measuring module with busbar connection IP00 Operator panel (front) and door adapter (front) with cover IP54 Shock resistance (sine pulse) g/ms 15/11 position Any Frequency Hz 50/60 ±5 % Immunity to electromagnetic interferences (acc. to IEC 60947-1) Corresponds to degree of severity 3 Line-induced interference, burst acc. to IEC 61000-4-4 2 (power ports) 1 (signal ports) Line-induced interference, high frequency acc. to IEC 61000-4-6 V 10 Line-induced interference, surge acc. to IEC 61000-4-5 2 (line to earth) 1 (line to line) Electrostatic discharge, ESD acc. to IEC 61000-4-2 8 (air discharge) 6 3) (contact discharge) Field-related interference acc. to IEC 61000-4-3 V/ m 10 Immunity to electromagnetic interference (acc. to IEC 60947-1) Line-conducted and radiated interference emission EN 55011/EN 55022 (CISPR 11/CISPR 22) (corresponds to degree of severity A) Protective separation acc. to IEC 60947-1, Annex N All circuits in SIMOCODE pro are safely separated from each other acc. to IEC 60947-1, they are designed with doubled creepage paths and clearances In this context, compliance with the instructions in the test report "Protective separation" No. 2668 is required. Basic units Snap-on mounting onto TH 35 standard mounting rail or Red/green/yellow LED "DEVICE" Green "BUS" LED Red "GEN. FAULT" LED Test/Reset buttons System interface Front Bottom PROFIBUS DP interface 1) For 3UF7 21: 0... +60 C. 2) For 3UF7 21: -20... +70 C. 3) For 3UF7 21: 4. Green: "Ready" Red: "Function test not OK; device is disabled" Yellow:"Memory module or addressing plug detected" Off: "No control supply voltage" Continuous light: "Communication with PLC/PCS" Flashing: "Baud rate recognized/communicating with PC or programming device" Continuous light/flashing: "Feeder fault", e. g. overload trip Resets the device after tripping Function test Operation of a memory module or addressing plug Connection of an operator panel or expansion modules; the memory module, addressing plug or a PC cable can also be connected to the system interface for parameterizing Connection of a current measuring module or current/voltage measuring module Connection of the PROFIBUS DP cable through terminal connection or through a 9-pin sub D socket 3/65

Basic units Control circuit Rated control supply voltage U s (acc. to EN 61131-2) 110... 240 V AC/DC; 50/60 Hz 24 V DC Operating range 0.85... 1.1 x U s 0.80... 1.2 U s Power consumption Basic unit 1 (3UF7 000) 7VA/5 W 5W Basic unit 2 (3UF7 010) incl. two expansion modules connected to basic unit 2 10 VA/7 W 7W Rated insulation voltage U i V 300 (at degree of pollution 3) Rated impulse withstand voltage U imp 4 Relay outputs Number 3 monostable relay outputs Auxiliary contacts of the 3 relay outputs Floating NO contacts (NC contact response can be parameterized with internal signal conditioning), 2 relay outputs are jointly and 1 relay output is separately connected to a common potential; they can be freely assigned to the control functions (e. g. for line, star and delta contactors and for signaling the operating state) Specified short-circuit protection for auxiliary contacts (relay outputs) Fuse links, gl/ga operational class 6 A, quick-acting 10 A (IEC 60947-5-1) Miniature circuit breaker 1.6 A, C characteristic (IEC 60947-5-1) Miniature circuit breaker 6 A, C characteristic (I k <500A) Rated uninterrupted current A 6 Rated switching capacity AC-15 6A/24V AC 6A/120V AC 3A/230V AC DC-13 2 A/24 V DC 0.55 A/60 V DC 0.25 A/125 V DC Inputs (binary) 4 inputs supplied internally by the device electronics (24 V DC) and connected to a common potential for acquiring process signals (e. g. local control station, key-operated switch, limit switch,...), freely assignable to the control functions Thermistor motor protection (binary PTC) Summation cold resistance kω 1.5 Response value kω 3.4... 3.8 Return value kω 1.5... 1.65 mm2 1 (0.5... 4.0); 2 (0.5... 2.5) mm2 1 (0.5... 2.5); 2 (0.5... 1.5) AWG cable (finely stranded) AWG 1xAWG20to14/2xAWG20to16 Current measuring modules or current/voltage measuring modules Current setting I e = 0.3... 3 A; 2.4... 25 A; 10... 100 A (3UF7 1.0, 3UF7 1.1, 3UF7 1.2) Current setting I e = 20... 200 A (3UF7 103, 3UF7 113) Snap-on mounting onto 35 mm standard mounting rail, screw fixing on mounting plate or direct fixing on contactor Current setting I e = 63... 630 A (3UF7 104, 3UF7 114) Screw fixing on mounting plate or direct fixing on contactor System interface For connection to a basic unit or decoupling module Main circuit 3UF7 1.0 3UF7 1.1 3UF7 1.2 3UF7 1.3 3UF7 1.4 Current setting I e A 0.3... 3 2.4... 25 10... 100 20... 200 63... 630 Rated insulation voltage U i V 690 1) (degree of pollution 3) Rated operational voltage U e V 690 Rated impulse withstand voltage U imp 6 2) Rated frequency Hz 50/60 Type of current Short-circuit Accuracy of current measurement (in the range 1 x minimum current setting I u to 8 x max. current setting I o ) % ±3 Three-phase current Additional short-circuit protection is required in main circuit Typical voltage measuring ranges Phase-to-phase voltage/line-to-line voltage (e. g. U L1 L2 ) V 110... 690 (only the phase voltages are available in SIMOCODE pro as measured values) Phase voltage (e. g. U L1 ) V 65... 400 Accuracy Of voltage measurement (phase voltage U L in the range 230... 400 V) % ±3 (typical) Of power factor measurement (in the rated load range power factor = % ±5 (typical) 0.4... 0.8) Of apparent power measurement (in the rated load range) % ±5 (typical) Notes on voltage measurement In non-grounded networks or in networks with integrated insulation measurement or monitoring Feeder lines for voltage measurement In these networks the current/voltage measuring module can be used only with an upstream decoupling module on the system interface. In the feeder lines from the main circuit for voltage measurement of SIMOCODE pro it may be necessary to provide additional line protection! 1) For 3UF7 103 or 3UF7 104 up to 1000 V. 2) For 3UF7 103 or 3UF7 104 up to 8. 3/66

Current measuring modules or current/voltage measuring modules Connection for main circuit Feed-through opening (diameter) Current setting I e = 0.3... 3 A; 2.4... 25 A mm 7.5 Current setting I e = 10... 100 A mm 14.0 Current setting I e = 20... 200 A mm 25.0 Busbar connections 1) 3UF7 100, 3UF7 101, 3UF7 102 3UF7 103, 3UF7 104 Current setting I e A 20... 200 63... 630 M8 x 25 Terminal screw M10 x 30 10... 14 Nm 14... 24 with cable lug 2 mm 2 Stranded with cable lug mm 16... 95 2) 25... 120 2) 50... 240 3) 70... 240 3) 6...3/0kcmil AWG cable AWG 1/0... 500 kcmil for voltage measurement mm2 1 x (0.5... 4.0); 2 x (0.5... 2.5) mm2 1 x (0.5... 2.5); 2 x (0.5... 1.5) AWG cable (finely stranded) AWG 1xAWG20to14/2xAWG20to16 Decoupling modules Green "READY" LED System interfaces Continuous light: "Ready" mm2 1 x (0.5... 4.0); 2 x (0.5... 2.5) mm2 1 x (0.5... 2.5); 2 x (0.5... 1.5) AWG cable (finely stranded) AWG 1xAWG20to14/2xAWG20to16 Digital modules Green "READY" LED Left interface for connecting to a basic unit or to an expansion module, right interface only for connecting to a current/voltage measuring module. Continuous light: "Ready" Flashing: "No connection to the basic unit" System interfaces For connecting to a basic unit, another expansion module, a current measuring module or current/voltage measuring module or to the operator panel Control circuit Rated insulation voltage U i V 300 (at degree of pollution 3) Rated impulse withstand voltage U imp 4 Relay outputs Number Auxiliary contacts of the 2 relay outputs Specified short-circuit protection for auxiliary contacts (relay outputs) Rated uninterrupted current A 6 Rated switching capacity 2 monostable or bistable relay outputs (depending on the version) Floating NO contacts (NC contact response can be parameterized with internal signal conditioning), all relay outputs are jointly connected to a common potential, they can be freely assigned to the control functions (e. g. for line, wye and delta contactors and for signaling the operating state) Fuse links, gl/gg operational class 6 A, quick-acting 10 A (IEC 60947-5-1) Miniature circuit breaker 1.6 A, C characteristic (IEC 60947-5-1) Miniature circuit breaker 6 A, C characteristic (I k <500 A) AC-15 6 A/24 V AC 6 A/120 V AC 3 A/230 V AC DC-13 2 A/24 V DC 0.55 A/60 V DC 0.25 A/125 V DC Inputs (binary) 4 externally supplied floating inputs, 24 V DC or 110... 240 V AC/DC depending on the version; inputs jointly connected to common potential for sensing process signals (e. g.: local control station, key-operated switch, limit switch...), freely assignable to the control functions mm2 1 (0.5... 4.0); 2 (0.5... 2.5) 2 mm 1 (0.5... 2.5); 2 (0.5... 1.5) AWG cable (finely stranded) AWG 1xAWG20to14/2xAWG20to16 1) Screw terminal is possible using a suitable 3RT19... box terminal. 2) When connecting cable lugs according to DIN 46235, use the 3RT19 56-4EA1 terminal cover for conductor cross-sections from 95 mm 2 to ensure phase spacing. 3) When connecting cable lugs according to DIN 46234 for conductor crosssections from 240 mm 2 - as well as DIN 46235 for conductor cross-sections from 185 mm 2, use the 3RT19 66-4EA1 terminal cover to ensure phase spacing. 3/67

Ground-fault modules Green "READY" LED Continuous light: "Ready" Flashing: "No connection to the basic unit" System interfaces For connecting to a basic unit, another expansion module, a current measuring module or current/voltage measuring module or to the operator panel Control circuit Connectable 3UL22 summation current transformer with rated fault currents I N A 0.3/0.5/1 I Ground fault 50 % I N No tripping I Ground fault 100 % I N Tripping Response delay (conversion time) ms 300... 500, additionally delayable 2 1 (0.5... 4.0); 2 (0.5... 2.5) mm2 1 (0.5... 2.5); 2 (0.5... 1.5) AWG cable (finely stranded) AWG 1xAWG20to14/2xAWG20to16 Temperature modules Green "READY" LED Continuous light: "Ready" Flashing: "No connection to the basic unit" System interfaces For connecting to a basic unit, another expansion module, a current measuring module or current/voltage measuring module or to the operator panel Sensor circuit Typical sensor circuits PT100 ma 1 (typical) PT1000/KTY83/KTY84/NTC ma 0.2 (typical) Open-circuit/short-circuit detection For sensor type PT100/PT1000 KTY83-110 KTY84 NTC Open circuit -- Short-circuit Measuring range C -50... +500-50... +175-40... +300 +80... +160 Measuring accuracy at 20 C ambient temperature (T20) K < ±2 Deviation due to ambient temperature (in % of measuring range) % 0.05 per K deviation from T20 Conversion time ms 500 Connection type Two- or three-wire connection 2 1 (0.5... 4.0); 2 (0.5... 2.5) mm2 1 (0.5... 2.5); 2 (0.5... 1.5) AWG cable (finely stranded) AWG 1xAWG20to14/2xAWG20to16 Detection possible -- Detection not possible 3/68

Analog modules Green "READY" LED Continuous light: "Ready" Flashing: "No connection to the basic unit" System interfaces For connecting to a basic unit, another expansion module, a current measuring module or current/voltage measuring module or to the operator panel Control circuit Inputs Channels 2 (passive) Parameterizable measuring ranges ma 0/4...20 Shielding Up to 30 m shield recommended, from 30 m shield required Max. input current (destruction limit) ma 40 Accuracy % ±1 Input resistance Ω 50 Conversion time ms 150 Resolution bit 12 Open-circuit detection With measuring range 4... 20 ma Output Channels 1 Parameterizable output range ma 0/4...20 Shielding Up to 30 m shield recommended, from 30 m shield required Max. voltage at output 30 V DC Accuracy % ±1 Max. output load Ω 500 Conversion time ms 25 Resolution bit 12 Short-circuit resistant Yes Connection type Two-wire connection Electrical separation of inputs/output to the device electronics No Nm 0.8...1.2 2 mm 1 x (0.5...4.0); 2 x (0.5...2.5) 2 mm 1 x (0.5...2.5); 2 x (0.5...1.5) AWG cable (finely stranded) AWG 1xAWG20to14/2xAWG20to16 Operator panels Red/green/yellow LED "DEVICE" Green "BUS" LED Red "GEN. FAULT" LED Green or yellow LEDs Keys Test/Reset Control keys System interface Front Rear Mounted in a control cabinet door or in a front panel, IP54 with system interface cover Green: "Ready" Green flashing: "No connection to the basic unit" Red: "Function test not OK; device is disabled" Yellow: "Memory module or addressing plug detected" Off: "No control supply voltage" Continuous light: "Communication with PLC/PCS" Flashing: "Baud rate recognized/communicating with PC or programming device" Continuous light/flashing: "Feeder fault", e. g. overload trip For assigning to any status signals, as required Resets the device after tripping Function test Operation of a memory module or addressing plug For controlling the motor feeder, user-assignable For plugging in a memory module, an addressing plug or a PC cable for parameterization Connection to the basic unit or to an expansion module 3/69

Operator panels with display Red/green/yellow LED "DEVICE" Green "BUS" LED Red "GEN. FAULT" LED 4 green LEDs s Keys Control keys Arrow keys Softkeys System interface Front Rear Mounted in a control cabinet door or in a front panel, IP54 with system interface cover Green: "Ready" Green flashing: "No connection to the basic unit" Red: "Function test not OK; device is disabled" Yellow: "Memory module or addressing plug detected" Off: "No control supply voltage" Continuous light: "Communication with PLC/PCS" Flashing: "Baud rate recognized/communicating with PC or programming device" Continuous light/flashing: "Feeder fault", e. g. overload trip For assigning to any status signals as required (preferably for the feedback of switching states, e. g. On, Off, Left, Right, etc.) Graphic display for indicating current measured values, operational and diagnostics data or status information For controlling the motor feeder, user-assignable Navigation in the display menu Various menu-dependent functions, e. g. test, reset, operation of a memory module or addressing plug For plugging in a memory module, an addressing plug or a PC cable for parameterization Connection to the basic unit or to an expansion module 3/70

Dimensional drawings Basic unit 1, SIMOCODE pro C, 3UF7 000 Basic unit 2, SIMOCODE pro V, 3UF7 010 3UF7 100, 3UF7 101 current measuring module (straight-through transformer) 3UF7 102 current measuring module (straight-through transformer) 3UF7 103 current measuring module (straight-through transformer) 3/71

3UF7 103 current measuring module (busbar connection) 3UF7 113 current/voltage measuring module (busbar connection) 3UF7 104 current measuring module (busbar connection) 3UF7 114 current/voltage measuring module (busbar connection) 48 145 11 25 67 149 6 122 147 88 125 9 32 NSA0_00404 3/72

3UF7 110, 3UF7 111 current/voltage measuring module (straight-through transformer) 3UF7 112 current/voltage measuring module (straight-through transformer) 3UF7 113 current/voltage measuring module (straight-through transformer) 3/73

3UF7 200 operator panel 3UF7 920 door adapter 96 NSA0_00385a 36 29 8 29 7 89 3UF7 210 operator panel with display 3UF7 3 digital module 3UF7 4 analog module 3UF7 5 ground-fault module 3UF7 7 temperature module 3UF7 15 decoupling module 60 55 96 91,5 NSA0_00463b 29 33 3UF7 922 adapter for operator panel NSA0_00464 63 51 100 62 38 37 3/74