Home Automation Systems Installation Guide for FFI Actuator & Control Projects

Similar documents
Stand Alone Actuator Systems

ACTUATOR. Terminal Blocks. Terminal Blocks. motor. motor. input 24 VDC. input 24 VDC. input 24 VDC RQ60DUM RQ60DUM. Control Circuit.

CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K)

RB24 Relay Box Installation Guide For use in low voltage motorized window and skylight systems

QUASAR Installation & Maintenance Guide motorized actuator for windows and skylights

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

Draper Low Voltage, Remote Control, Serial and Network Wiring Guide

Energy Meter and. Current Transducer. Assembly Manual

SAVE THESE INSTRUCTIONS

7A HDQ MOTOR WIRING AND PROGRAMMING

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

Wa r n i n g-wa r n i n g-wa r n i n g

Satellite INSTALLATION GUIDE

Catalog Number Identification with Elements Explained V V V V X 347 V Hz

PowerShield 8. Installation Manual

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

ORB TM 4-20 ma Input Box Installation & Operation Manual

THE CTB08D LIGHT CONTOLLER

2016 MacroAir Technologies Toll Free: Fax:

VG-305A AC Traffic Light Controller Kit

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Next Gen Sarix Enhanced IBE Series Bullet Cameras

DIRECT POWER LIGHTING MANUAL

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

Xcel Energy Telemetry Requirements for Distributed Energy Resource Interconnections: Revision 3.1

Quick Start Guide TS A

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures)

Operating instructions. Switching amplifier DN0210 DN / / 2015

IMPORTANT SAFETY INSTRUCTIONS

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

DMX, 2 CHANNEL 2 Channel DMX Driver

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina

DMC2. Installation Guide Version 1.0. Area for main photograph. Area for insert photo. W: 46.1mm up to 79 mm H: 46.1mm

D1V Rotary Control Panel D4S Button Panel PS Power Distribution Module USER MANUAL

Installation Instructions & User Manual POWERWARE TVSS ZONESENTINEL. AC Panel Transient Voltage Surge Suppressors

USB 3.1 CAT6A/7 EXTENDER

2012 Dealer Price List

Occupancy and Vacancy Sensors ROOM CONTROLLER* DAYLIGHT SENSOR WPP-INT INSTALLATION GUIDE

Compact, Low Profile High Rendering, 100% Diffusion

ALTAI C1N SUPER WIFI CPE INSTALLATION GUIDE. Version 1.0 Date: September, Altai Technologies Ltd. All rights reserved

LED. Sign Module. Assembly Manual

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

Expandable Power Systems

Wireless Area Controller (WAC60)

USB 2.0 CAT5E/6/7 EXTENDER

Overview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel.

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Installing Sentor. Hardware Installation

Wiring and Configuration Instruction

4 Channel DMX Driver Instruction Manual

Installation manual for for Schleifenbauer DPM3

P M C L O G I C. 10 Inputs High-side or Low-side /110 PMC 10 Channel Input Module. PMC Input Module 110

M250 (M LL) Safety


AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

This document describes the procedure for doing a power trace on the SM5 and Gauntlet Stepmills.

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

Modem Installation and Networking Instructions

Operating instructions. Speed monitor D / / 2014

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Autoranging True RMS Multimeter User Manual

EnerSure Installation Guide

ELECTRONIC DISPLAYS INC. 135 S. CHURCH STREET ADDISON, ILL

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

INDEX. Analog Board Boot and Voltage Test 2 Testing Input Channels 3 Testing Output Channels 4

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

USB 2.0 DIGI-USB2 1-Port USB m Category 5e/6/6a/7 Extender Set with Flexible Power. User Manual. Revision

VADDIO /CANON BU-SERIES PTZ CAMERAS

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

Trademark Generation II Series Intercom System Installation and Operation Reference Guide

PV Rapid Shutdown device

Infosystem Remote Touchscreen Installation Instructions

INSTALLATION MANUAL. ST-BTWD650IR2812 B or W Weatherproof Day/Night Infrared Color Camera


Conveyor Belt Alignment Switches from IDEM

Installing the Enphase IQ Commercial Envoy

Keypad CT2000. Art. No.: , (black) Art. No.: , (white) Installation Manual

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

*****CAUTION/ATTENTION***** Before You Start...

INSTALLATION INSTRUCTIONS

Rako RAK4-R Instruction Manual

Instruction Manual. Contents

TOUCH TRACKER with Quad Splitter

Model HM-535 Power Supply Installation and Service Instructions

KTD-125/ KTD-125P/125P-24 KTD-127/127W PTZ Receivers

Resolver to Digital Expansion Board

Square D Clipsal Pascal Automation Controller

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

2 in 1 LAN Tester and Multimeter Model:

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

BCM2 Series Branch Circuit Monitors Quick Setup Guide

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

Installation Instructions 4291 and 4292 Keypads

Transcription:

Home Automation Systems Installation Guide for FFI Actuator & Control Projects This installation guide is for home automation systems such as Crestron, Lutron and others which communicate with FFI controllers and actuators. Accessory adapters/translators may be necessary, depending on the system. System Layout It is important to look at the diagrams of your system layout from FFI and understand how the components are to be connected together. Control panels must be placed in the correct locations of the building to operate as planned. There are 3 ways for FFI controllers to interface with home automation systems: by dry contact, by RS-232 protocol, and by RS-422 protocol. Example: Home Automation System layout diagram. For reference only not project specific. PSIB accessory can be used in many instances, it is used more often when there are 2 or more RQ s. Diagram elements are not to scale. 21-Mar-14 page 1 of 13 800-677-0228 www.fenestration.net

System Connections Cable Routing Recommendations: Always keep data cable at least 18 inches away from an AC power line. If it is necessary to cross AC power, do so at a 90 degree angle to reduce electrical interference. Do not run data cabling with power lines inside conduit. Do not bend data wire any tighter than 4 times the diameter of the cable; any more will risk breaking conductors inside the jacket. Run data cable High and Tight by keeping cables away from other objects and securing them when possible. FFI Control Panel containing a power supply and controllers Do not add non-essential components or disconnect internal wires or components! 21-Mar-14 page 2 of 13 800-677-0228 www.fenestration.net

Data Connections Data Cable Selection CAT5/5e cable is best for long runs. CAT6 cable is not recommended. RJ-25 (6P6C) modular connectors are required for FFI control panels. Always test your data cables. Before installing, also read the FFI Cables Data Sheet for important instructions. Do not add non-essential components or disconnect internal wires or components! CAT5/5e cable RJ-25 modular connector Data Ports Controllers have a QAUX port and a QEYE port as shown below. Multiple controllers and control panels can be connected by EYE to AUX ports, or by AUX to AUX ports, but never by EYE to EYE ports. This applies to other FFI components as well such as bridges. RQ controller orientation in the control panel may vary, so please pay close attention to each RQ controller to be certain you are connecting to the correct ports. See RQ Controller Connections page for more information. Controllers connected by EYE to AUX ports and AUX to AUX ports 21-Mar-14 page 3 of 13 800-677-0228 www.fenestration.net

System Example: Three DC actuators with FFI Control Panel, PSIB, momentary contact switch, and connection to Home Automation System. For reference only not project specific. PSIB accessory can be used in many instances, it is used more often when there are 2 or more RQ s. Diagram elements are not to scale. 21-Mar-14 page 4 of 13 800-677-0228 www.fenestration.net

System Example: DC actuators with FFI Control Panels, dry contact switch, and connection to Home Automation System. For reference only not project specific. Diagram elements are not to scale. 21-Mar-14 page 5 of 13 800-677-0228 www.fenestration.net

System Example: DC actuators with FFI Control Panels, a wall-switch with PSIB and bus splitter, and connection to Home Automation system. For reference only not project specific. PSIB accessory can be used in many instances, it is used more often when there are 2 or more RQ s. Diagram elements are not to scale. 21-Mar-14 page 6 of 13 800-677-0228 www.fenestration.net

Home Automation Systems Dry Contact Momentary: Single Pole Double Throw (SPDT) Warning! Do not apply voltage to the dry contact inputs. SPDT switch connection to a controller Home Automation Systems RS-232 protocol RS-232 requires a bridge and RS-232 adapter to connect controller with home automation systems. 21-Mar-14 page 7 of 13 800-677-0228 www.fenestration.net

Home Automation Systems RS-422 protocol RS-422 requires a bridge to connect with home automation systems. The RS-422 Data BUS is capable of a combined length of 3200 feet in four networks. This is an electrical limit and cannot be exceeded on a single network. For more information contact FFI. Optional Components for FFI actuator & control systems PSIB Programmable Switch Interface in a Box Can be used to connect a group of FFI Actuators to a local switch and bypass a central BUS command. Allows fewer wire runs, with decentralized control. Bus Splitters To add or make connections to the data bus. Mounted in plastic enclosures. asp2e2qb - for 2 Eyes and up to 2 RQ Motor Controls SP1E3QB - for 1 Eye and up to 3 RQ Motor Controls SP2E2Q- for 2 Eyes and up to 2 RQ Motor Controls SP1E3Q - for 1 Eye and up to 3 RQ Motor Controls 21-Mar-14 page 8 of 13 800-677-0228 www.fenestration.net

Actuator and Power Connection to the FFI Control Panel Do not add non-essential components or disconnect internal wires or components! The FFI Control Panel has knock-outs on all sides for easy access to connect actuators and power. Actuator connection Connect to the terminal strip provided inside the FFI Control Panel. Connect positive wire to positive terminal, and negative wire to negative terminal. For actuator wire colors and details, see the Installation Guide for your actuator model. Power connection Connect to the internal power supply, 110 VAC from external source. Connect Black (hot) wire to L. Connect White (neutral) wire to N. FFI Control Panel For reference only not project specific. Contact FFI for details and options. RQ controller orientation in panel may vary; for more on this, see RQ Controller Connections page. 21-Mar-14 page 9 of 13 800-677-0228 www.fenestration.net

RQ Controller Connections The white label on top of the RQ controller card shows where all of the connections are located on the RQ controller. The white label shows where to find the connections for the following: The QAUX and QEYE ports. The dry contacts for OPEN, COMMON, and CLOSE. The Actuator connections (MOT) and Power connections (NEG and POS). Note: Do not tamper with these, as they are pre-wired for every Control Panel. Important: The label may be in any of four orientations as you look at it. The orientation can change depending on the design of the Control Panel containing the RQ controllers. Please pay close attention to each RQ controller to be certain you are connecting to the correct contacts. The QAUX and QEYE ports are particularly important to connect correctly, as it can be easy to confuse the two. Below are examples to illustrate this. The white label may have different orientations as you look at different RQ controllers, as shown below. The white label indicates the location of the connections on the particular RQ controller, as shown below. Connect only at orange arrow points; do not tamper with other wiring or components. 21-Mar-14 page 10 of 13 800-677-0228 www.fenestration.net

Initializing the system using keypad or PC program Initialization tells the controllers the amount of time it takes for the actuators to fully open and close. Please note if you have a custom keypad overlay, please contact FFI to confirm these instructions. Initialize using FFI Keypad, part # K24ST 1. Connect the FFI Keypad to the control panel at the end of the string of connected controllers (see Fig. A). Connect using a JP12 cable (part# JP12) into a QEYE port (see Fig. B). First unplug any cable currently in that port. The keypad indicator light will blink a few times to show it is powered. Fig. A Fig. B 2. Enter the following into the FFI Keypad as shown in the steps below. Each step must be entered within approx. 3 seconds of the previous step, or the command sequence will stop. Step 1: Press and hold together: 7 and 19 and STOP (also known as OPEN 7, CLOSE 7, STOP.) Step 2: When red LED light begins to flash, Press OPEN (ALL) Red LED Light Step 3: Press 22 (also known as CLOSE 10.) Step 4: Press 10 (also known as OPEN 10.) 21-Mar-14 page 11 of 13 800-677-0228 www.fenestration.net

3. The actuators will all open, close, then finish in the open position. This will take a few minutes. 4. To close the actuators and windows, press the CLOSE (ALL) button. 5. To re-test opening and closing all of the actuators in the string of controllers, use the steps below. If all of the actuators in the string open and close at the same time, then initialization is complete. Step 1: Press OPEN (ALL) Step 2: Press CLOSE (ALL) 6. Finally, disconnect the JP12 cable from the control panel, and initialization is done. 7. If the actuators do not all open and close at the same time: a) Repeat at least 2 more times entering the commands into the FFI Keypad. b) Check that the cable from the keypad is connected to the correct port on the correct controller card. c) Check that all cables are plugged in securely, and to appropriate QEYE or QAUX ports. d) If these do not work, see Troubleshooting section. Initializing using a PC with Terminal Emulator program (optional, instead of keypad) Terminal Emulator software can give commands and perform system inquiries as well as perform Initialization. For more information, contact FFI. 21-Mar-14 page 12 of 13 800-677-0228 www.fenestration.net

Troubleshooting Questions? Troubleshooting? Call FFI at 800-677-0228. But first (1) Always test your data cables. Use a cable tester to check all cables connected to the card and control panel. For more details, see FFI Cables Data Sheet. (2) Test for Power. Check that the controller card is getting power. The controller card has a green LED that lights up briefly when it receives a command; if it is lighting up, then it is getting power. This can be checked by connecting a keypad to the QEYE port and pressing the STOP button. Green LED Light (3) Test for Continuity with a multi-meter. Use a multi-meter to check the continuity between the power supply and the terminal block(s). As shown on diagram to the right, touch the multi-meter to the screw-heads on the power supply and each terminal block in the control panel as indicated by the orange arrows. Test between these negative connections, then positive connections. Do not disconnect any internal wiring. If you do find a continuity problem, next test the fuse by probing at each end of the fuse. Fuse Power Supply Terminal Block (4) Do not add non-essential components or disconnect internal wires or components! (5) Check system status using a PC Terminal Emulator program. For more information, contact FFI. (6) If all of the actuators are working together to a certain point in the string, and beyond that point no actuators are working, then the first non-operational actuator indicates which controller card is experiencing a problem. Check that card to look for the problem. (7) The FFI Field Power Switch is available for use with FFI DC actuators, for testing and installation. (8) Contact FFI for assistance. FFI Field Power Switch Part # SW.FPS.01 Recommendations for FFI Actuators & Controls: FFI only recommends UL compliant systems. FFI is a UL Registered firm. Read FFI data sheets & installation guides before specifying project details. Project-specific needs vary depending on the number of actuators, electrical layouts, building management systems, distance between power supplies & actuators, and other details. Project specifications to comply with electric & building codes for wire gauge, wire connections and run distance, conduits, junction boxes must be arranged by the project electrical contractors. Distribute this guide to all project parties, including electric contractors, architects and building management personnel! 21-Mar-14 page 13 of 13 800-677-0228 www.fenestration.net