The Electronic-Key-System EKS

Similar documents
Product Overview ManMachine

Identification System CIS3A-Mini

INDUSTRY. Ongoing dialog. Communication at Industry 4.0 level

Transponder-coded. with guard locking

EKS Light FSA on Siemens S7-300 operation mode selection with touchscreen

More than safety. Product Overview. ManMachine

Versatile and safe. Transponder-coded safety systems CES

Safety System CES-FD. Non-contact safety system CES-FD- Direct connection to decentralized peripheral systems (e.g. ET200pro) PLC

EKS PROFINET Selection of Operating Mode with Pushbuttons

More than safety. Product Overview. Safety Engineering

Safety light grids and light curtains LCA

Product Overview Automation

Setting up the EKM software as a programming station

Product Overview Safety Engineering electro-mechanical

The safe choice Selection of operation mode with EKS up to PL e

Operating Instructions

Safety Switches CES-AR/CET-AR

Product Overview Safety Engineering electronic

PHOENIX CONTACT - 05/2007

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

Non-Contact Safety System CES-AZ

More than safety. System Manual Safety System MGB-AR in combination with a locking module MGB-L1-AR-.../MGB-L2-AR-...

Datasheet - RSS 36-D-R-ST

PHOENIX CONTACT Features

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

Fieldbus Gateway Type ME43

More than safety. Operating instructions Non-contact safety system CES-A-AEA-02B/CES-A-AEA-04B (Unicode)

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

Online data sheet. T40-E0101K T4000 Direct NON-CONTACT SAFETY SWITCHES

Magnetically Coded Safety Switches CMS

Faults on the system Proximity switch connection technology:

GS202 Encoder Switch

(see also technical drawings) Width with inlay

Flow Sensor SONOFLOW CO.55

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341

PI-EX-ME-2NAM/COC-24VDC

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Inductive sensor BI5-EM18-Y1X-H1141

PowerDRIVE-Box GEL 6505 Interface for controlling up to 5 positioning drives

E-STOP relay, safety gate monitor

STEP-PS/1AC/24DC/1.75

Profi le PF. Contents. PF General data 106 Analog interface 108 IO-Link V Floating magnet 112 Captive magnet 114

Data Sheet. Thumbwheel Switch Multiswitch, Series B

Pneumatic Control/Feedback

Pneumatic Control/Feedback

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Inductive sensor NI3-EG08K-Y1-H1341

Extract from the online catalog

Digital electropneumatic positioner

QUINT-PS/ 1AC/24DC/ 5

PHOENIX CONTACT - 07/2006

The SMART Non-contact Safety Sensor SRF With an innovative diagnostic system

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2TAZ710xx1R2161

ABB i-bus KNX Analogue Actuator, 4-fold, MDRC, 0-10 V, 0-20 ma AA/S 4.1.2, 2CDG110202R0011

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

LED Driver Linear / area fixed output

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Inductive sensor BI1.5-EG08-Y1-H1341

Electronic Level Switch ENS 3000

Control Head for the integrated mounting on process valves

More than safety. Operating instructions Non-contact safety system CES-A-ABA-01/CES-A-ABA-01B (Unicode)

Interlock Switches. Selection Guide. HS7A-DMC Magnetic Safety Switches

IF-80x Outdoor Terminal

Signal Doublers. VariTrans A 20300

ABB i-bus KNX Switch Actuator, x-fold, 10 A, MDRC SA/S x , 2CDG11015xR0011

warning indication issued about 2 weeks before the battery charge becomes critical Real-time clock - with battery back-up Yes

PHOENIX CONTACT - 12/2007

Type Quickstart

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

PI-EX-ME-2NAM/COC-120VAC

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

PHOENIX CONTACT - 01/2008

Safety Switches CES-AR/CET-AR

onlinecomponents.com

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

Non-Contact Safety System CES-AZ

E-STOP relay, safety gate monitor

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

ABB i-bus KNX Analogue Input, 4-fold, MDRC AE/S , 2CDG110190R0011

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Digital electropneumatic Positioner for the integrated mounting on process control valves

Operating instructions. Switching amplifier DN0210 DN / / 2015

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Demonstration Case BENNING DB 1

LED Driver Linear / area fixed output

PT 2X2-24DC-ST. Extract from the online catalog. Order No.:

Operating Instructions

More than safety. Operating Instructions Non-Contact Safety Switch CES-AR-C01-EH-SA (Fixcode)

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

Electrical connection

Linear Position Transducer HLT 1000-R2

HARTING econ 3000 Introduction and features

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

Connection of CET3-AR to Pilz PDP67

Retro-reflective photoelectric sensors with polarisation filter. Dimensioned drawing. Electrical connection

Operating Instructions

Transcription:

The Electronic-Key-System EKS This system is already established in many applications involving electronic access management on PCs and control systems. The user employs the Electronic-Key with RFID transponder to identify himself to the Electronic-Key adapter. Thanks to the special design of the Electronic-Key adapters, the Electronic-Key can be placed on the installation during operation. The EKS is widespread amongst automotive manufacturers and suppliers. Further applications include uses in the process-oriented industry, e.g. in the production of food, pharmaceutical or chemical products. Protecting access to critical processes is a central topic in the typical applications. The existing EKS family is being expanded by another series with the EKS Light. With EKS Light, EUCHNER is now opening up the use of EKS technology for small and decentralized applications as well. Due to the non-contact transfer of data, it was possible to design the Electronic-Key adapters from the access side with a high degree of protection. Thanks to its robust design, the EKS is appreciated as one of the few truly industry-compatible systems. The EKS is well-known in the compact version Here, the Electronic-Key adapter and the electronics with the interface form a unit. The Electronic-Key latches into the Electronic-Key adapter and is retained there. The compact EKS Light Electronic-Key adapter can be identifi ed by the black front cover. Even more options with the EKS in modular version Here, the Electronic-Key adapter is mounted spatially separate from the electronics. The modular Electronic-Key adapter allows the Electronic-Key to be recognized at the front upon approach, and the Electronic-Key can also be placed by hanging it if neces- sary. With the modular design, the electronics is accommodated in a separate interface adapter mounted in the control cabinet or on a DIN rail, for example. The special features and advantages of the modular Electronic- Key adapter: Compact design for installations where there is little space Installation in standard mounting hole Ø,5 mm Closed design, rounded contours for hygienic areas Plastic with high resistance to media The shallow installation depth permits installation in fl at control panels as well. Since this version fi ts in a Ø.5 mm hole, it is often the simplest solution for retrofi tting in particular. The Electronic-Key adapter was designed for applications in hy- gienically sensitive areas, with simple cleaning being of primary importance here. The high-molecular-weight plastic also permits use in the food industry.

Access the easy way... A simple connection concept as well as rapid and therefore economical integration into the control environment were at the forefront in the development of EKS Light. Compatibility with the existing EKS through the use of the same Electronic-Keys was also taken into account. Electronic access control Simple connection Simple communication, 4-bit output Very fl exible use As previously with EKS, the Light version also permits controlled access to individual machines, entire installations or other facilities. The only diff erence is that with EKS Light, the device directly identifi es a user by his Electronic-Key. A control system is not necessary for this check. If an authorized user was detected, an access level is output with which the user receives a certain authorization. The derivation of access rights onto machine functions is carried out through the programming of the control by the system integrator. And this is how it works The EKS Light Electronic-Key adapter is a read-only system with evaluation electronics and interface. After the key is inserted, the key's data are evaluated within the device as the fi rst step, which permits automatic user recognition without the aid of the control system. Once the internal check of the data integrity is complete, an access level is issued. The access level is output via a 4-bit parallel interface. The parallel interface off ers the advantage of transparent depiction of the data and therefore simple connection directly to the inputs of a control system or a switching device. An EKS operating state, an access level, an access code, a checksum (CRC) and a serial number are stored on the Electronic-Key. When a key is inserted, the data range relevant for the respective operating state is automatically read from the key into the device, temporarily stored there and evaluated. If an authorized user is recognized via a valid Electronic-Key, the outputs on the Electronic-Key adapter are set to High in accordance with the stored access level values. All outputs are reset to Low when the Electronic-Key is withdrawn. 0000000011 0000000000 The Electronic-Key adapter and Electronic-Key are separately parameterized, with values which have to match. Parameter assignment to the Electronic-Key adapter is performed very simply through DIP switches. 4-Bit parallel interface for output of the access level Switched Outputs 0 / 4 V A = 1 B = C = 4 D = 8 Strobe Level 7 Legitimated

Flexibility through various operating states The application options for EKS Light are diverse, and the fl exible concept with its diff erent operating states provides fl exibility for planning. The operating state determines the function of the system, which comprises the Electronic-Key adapter and Electronic-Key. The operating state defi nes the scheme according to which automatic Electronic-Key recognition functions and how an access level is issued. What operating states are available? Depending on the applications, various operating states can be selected. Two diff erent operating states are available in the fi rst step. Operating state 0 Access is granted when the access codes on the Electronic- Key and DIP switch are an exact match. 104 codes are possible in this operating state. Operating state 1 Access is granted when there is a match on any bit position of the access codes on Electronic-Key and DIP switch. Example for access to operating state 0 Access Code DIP Switch 1 0000000001 0000000001 0000000001 Access group 1 958 1110111110 1110111110 group 958 10 1111111111 1111111111 1111111111 group 10 Example for access to operating state 1 Access Code DIP Switch 1 0000000001 0000000001 0000000001 Access group 1 0000000010 0000000010 group 1+ 0000000011 0000000011 Superior User 1111111111 all 10 1000000000 1000000000 1000000000 group 10

Electronic-Key-Manager EKM How are parameters assigned to Electronic-Keys? Parameter assignment for the Electronic-Keys is performed exclusively via a programming station on the PC. At least the following items are required for this purpose: A commercially available Windows PC An EKS Electronic-Key adapter with USB interface The Electronic-Key Manager EKM Light software Doe John Programming takes place via the Electronic-Key-Manager EKM software with an EKS Light input mask suitable for the operating state: The EKM Light Version is suffi cient at fi rst. It can be upgraded to an EKM single-user or full version later. With this upgrade there is always a good overview about the database and all the already entered Electronic Keys. The cyclic redundancy check routine prevents data manipulation outside of the defi ned software environment. Programming station EKS Electronic-Key adapter with USB interface in desktop case at the PC Ordering table Designation Item Order no. in red color EKS-A-K1RDWT-EU 077 859 in black color EKS-A-K1BKWT-EU 084 75 in blue color EKS-A-K1BUWT-EU 091 045 Electronic-Key read/write** in green color EKS-A-K1GNWT-EU 094 89 in yellow color EKS-A-K1YEWT-EU 094 840 in white color EKS-A-K1WHWT-EU 1 097 in orange color EKS-A-K1OGWT-EU 1 098 Compact version Electronic-Key adapter EKS Light compact (supports only operating state 0) EKS-A-IPB-G01-ST05/0 111 0 Electronic-Key adapter EKS Light compact (supports all operating states) EKS-A-IPL-G01-ST05/0 109 80 Electronic-Key adapter EKS Light FSA compact (supports all operating states) EKS-A-IPLA-G01-ST05/04 11 07 Modular version Electronic-Key adapter EKS Front hook modular FHM, cable m with fl ying lead* EKS-A-SFH-G0-000 106 585 alternatively... Electronic-Key adapter EKS Front hook modular FHM, cable 0.1 m with M8 male plug* EKS-A-SFH-G0-ST150 116 118 Cable length m C-M08F04-04X05PV0,0-ES 084 641 Connection cable with M8 female plug and fl ying lead, Cable length 5 m C-M08F04-04X05PV05,0-ES 084 64 required for order no. 116 118 Cable length 10 m C-M08F04-04X05PV10,0-ES 084 64 Cable length 15 m C-M08F04-04X05PV15,0-ES 084 644 Interface adapter EKS Light modular (supports only operating state 0)* EKS-A-APB-G08 11 665 Interface adapter EKS Light modular (supports all operating states)* EKS-A-APR-G08 11 647 Interface adapter EKS Light FSA modular (supports all operating states)* EKS-A-APRA-G08 11 645 For setting up a programming station Electronic-Key adapter with USB interface** EKS-A-IUX-G01-ST01 09 750 Electronic-Key-Manager EKM **, software Light Version***, on CD 111 410 Desktop case for mounting the EKS USB Electronic-Key adapter (optional) EKS DESKTOP CASE 11 106 Documentation EKS Light manual, pdf fi le available at www.euchner.de in the area Service/ Downloads/ 110 845 * A complete read station consists of the FHM Electronic-Key adapter and an interface adapter ** Detailed information about the standard EKS software and hardware components in the EKS catalog *** Alternatively the EKM demo version (runtime limited), EKM single-user version or full version can be used

Dimension drawing Electronic-Key adapter EKS Light compact plug-in screw terminal 40 LED 70 60 max. 4 mm 0V UB A B C 8 75 76 67 D Str DIP switch 8 4 M 1,5 (rubber gasket) 50 10 Dimension drawing Electronic-Key adapter EKS Light FSA compact plug-in screw terminal 40 LED 70 60 max. 4 mm 8 75 LA 0V UB LA1 76 67 A B C D Str DIP switch 8 4 M 1,5 (rubber gasket) 50 10 Dimension drawing Interface adapter EKS Light modular Interface adapter EKS Light FSA modular passend für Hutschiene 5mm nach DIN EN 500-5 / suitable suitable for rail for rail 5 mm 5 mm according to DIN to DIN EN EN 500-5 60715 TH5,5,5 114 Dimension drawing Electronic-Key adapter EKS Front hook modular FHM Datenblatt / Data Sheet 5 EKS-A-SFH-G0-000-106585 min. 5 max. 4 mm 44 H1 H LED1 H1 LED H LED1 LED UB 0V SH UB 0V SH EKSLight FSA EKSLight FSA 50 STATE STATE ACTIVE ACTIVE DIA DIA Str. LA1 0V Str. LA LA1 0V LA D C B DA C B A 99 4 Entwurf Mx1 cable Leitungslänge length 000 mm

FSA Version (For Safety Applications) The Electronic-Key adapter EKS Light is alternatively available in the FSA (For Safety Applications) version. To solve the widespread problem of tampering with safety guards, EKS Light has been expanded for safety-related applications in conjunction with operating mode selection. The access rights are assigned via EKS in the fi rst step and the desired operating mode is selected via another device in the second step. Trained personnel are thereby specifi cally authorized to perform critical setup and maintenance work in a special, hazardous operating mode. The FSA version features an additional fl oating switched semiconductor switching contact that can be utilized to form a safe shut-down signal. For this purpose a safe evaluation must be connected downstream. The EKS Light FSA can thereby be used for safety-relevant applications. The machine is reset to a safe operating mode by removing the Electronic-Key. Functionality of FSA version Access rights system Selection system Safety guard EKS Light FSA Auto Auto Auto Auto Safety guard bridged Auto Auto Auto

Technical data Value Unit General parameters Electronic-Key adapter compact min. typ. max. Housing Plastic (PA 6 GF0 grey/black) Degree of protection according to EN 6059 IP 65, IP 67 in mounted condition Ambient temperature at U B = 4 V DC -0 +70 C Mounting cut-out according to DIN 4700 x 68 mm plug-in screw terminals - and 5-pole Connection type for power supply, outputs and plug-in screw terminals 4- and 5-pole (FSA version) semiconductor switching contact Conductor cross-section 0.14... 1.5 mm², tightening torque 0. Nm General parameters Electronic-Key adapter Front hook modular FHM Housing Plastic (PVDF GF0 gray) Degree of protection according to EN 6059 IP 65, IP 67, IP 69K in mounted condition Ambient temperature -0 +70/+100* C Mounting hole Ø,5 mm Connection Connection cable m with fl ying lead or Connection cable 0.1 m with plug connector M8, 4-pole Connection cable length, 5, 10, 15 m Connection cable cross-section 4 x 0,5 screened mm² Connection cable outer sheath PVC General parameters interface adapter modular Housing Plastic (PA 6.6) Ambient temperature at U B = DC 4 V -0 +55 C Mounting 5-mm DIN rail acc. to DIN EN 60715 TH5 Number of Electronic-Key adapters to connect 1 Connection type power supply, outputs, Electronic-Key adapter and semiconductor switching contact (FSA) Four plug-in screw terminals, 4-pole, Conductor cross-section 0.14....5 mm² Cable length to Electronic-Key adapter 15 m Electronics, interface and signaling Operating voltage U B (regulated, residual ripple < 5 %) 9 4 8 DC V Current consumption I B (without load current) 70 ma Interface to inputs of control system or switch unit 4-bit parallel plus strobe, binary coded via High/Low level Load current per output I A 1 10 50 ma Bestelltabelle Output voltage U A (High level) for A,B,C,D, Strobe U B - U B V Cable length to control system 50 m LED-indicator Green:»Ready«(in operation), Yellow:»Electronic-Key active«**, Red:»Error«FSA version (For a Safety Applications) - parameters for floating semiconductor switching contact LA Power supply U for load (LA) 4 0 V Switching current (with overload protection***) 1 10 50 ma Output voltage U A (LA) in switched state U x 0,9 U V Resistance in switched state 5 Ohm Capacitive load 1 µf AC-1 DC-1 Utilization category AC-15 according to EN 60947-5- DC-1 50 ma / 4 V Reliability values according to EN ISO 1849-1 (only FSA version) Category (with connected safe evaluation) MTTFd 00 Years DC 9 % * This is not the ambient temperature for operation. It is valid for a time duration of max. minutes, e. g. for cleaning purposes ** The LED illuminates yellow if there is a valid Electronic-Key in the Electronic-Key adapter *** Function description of the overload protection in the Electronic-Key adapter manual, order No. 110 845 111510-08-11/15 Subject to technical modifi cations without notice, no liability will be assumed for any detail. EUCHNER GmbH + Co. KG TA EUCHNER GmbH + Co. KG Kohlhammerstraße 16 70771 Leinfelden-Echterdingen Germany Tel. +49 711 7597-0 Fax +49 711 7516 info@euchner.de www.euchner.com