BASE LOAD UNLOAD 3 PRODUCTS 6 PRODUCTS 14 PRODUCTS Multiprogram

2 Made in Italy Electronic Instruments for weighing and batching LAUMAS produces Weight Indicators and Transmitters for PC/PLC connection to the most

Installation and User Manual version 1.04 TLM8 2014/30/UE EN55022:2010 EN :2005 EN :2007 SYSTEM IDENTIFICATION

PENKO Engineering B.V. When Weighing Counts FLEX Multi Channel Extended

ENGLISH ENGLISH ENGLISH ENGLISH

Characteristics and functioning

WTX120. Legal-for-trade industrial weighing terminal. Special features. Data sheet

Presented By. NicolScales.com Contact Us

C500 Series Data Sheet

Weight Indicator. Model Intuition 22i FEATURES APPLICATIONS DESCRIPTION OPTIONS CONFIGURATION

Characteristics and functioning

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

T1-transmitter. 4-20mA 0-20mA 0-10V 0-5V +/-5V +/-10V 2014/30/EU EN55022:2010 EN :2005 EN :2007

M260 Load Cell Amplifiers

ENGLISH ENGLISH ENGLISH ENGLISH

OIML CERTIFICATE OF CONFORMITY

The LT1300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

User Manual version 1.04 TLM8 COMMUNICATION PROTOCOLS

enod4 Weighing controller for automated systems

OIML CERTIFICATE OF CONFORMITY

ENGLISH ENGLISH ENGLISH ENGLISH

ABB MEASUREMENT & ANALYTICS DATA SHEET. IT1 Universal weighing terminal

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

EU Type Examination Certificate

CERTIFICATE of EU TYPE-APPROVAL

EC Type-Approval Certificate

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

TECHNICAL DATA. Option: Connection of scale platforms with digital force transducers. Option: up to 6 external scale connection.

T1 4-Channel Protocol Manual

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

Protocol Manual. Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever.

EC Type-Approval Certificate

TLS. Installation and User Manual version mA 0-20mA 0-10V 0-5V +/-5V +/-10V 2004/108/EC EN55022 EN EN

WTX110. Legal-for-trade industrial weighing terminal. Special features. Data sheet

OIML CERTIFICATE ISSUED UNDER SCHEME A

Fieldbus slave modules w/o I/Os

Weight controller Maxxis 5

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

Presented By. NicolScales.com Contact Us

CAPITAL SCALE CC TEL: (012) FAX: CELL: ADVANCED MASS MEASUREMENT

enod4 weighing controllers For automated processes

UniPak UP448 Bridge Input Isolating Signal Conditioner

ioselect Z-NET Z-SG Bridge Input Isolating I/O Module

T1-transmitter. 4-20mA 0-20mA 0-10V 0-5V +/-5V +/-10V 2014/30/EU EN55022:2010 EN :2005 EN :2007

EC Type Examination Certificate

Maxxis 4 Process Controller with BASIC Application

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

Neon pr. ph/ ORP measurement. Applications. Description

T1-CANopen 2014/30/EU EN55022:2010 EN :2005 EN :2007

Force/Displacement Measuring System

smart meters... 6 panel meters... 7 field displays... 8 display types loop powered displays TRANSMITTERS & CONVERTERS...

DIGITAL LOAD CELLS NEXT GENERATION EILERSEN EXPERTS IN WEIGHING SINCE Robust digital load cells. Tolerate up to 1000% overload

Transmitter WST 3 From prog. name W001A100. Technical Manual

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

LAUREL. Laureate Rate Meter & Totalizer with Functions A+B, A-B, AxB, A/B, A/B-1 ELECTRONICS, INC. Features. Description

Deutschmann Automation,

PUE 5 Indicator. Reliability in industrial conditions Complex support of weighing process. Functions. Features

STANDARD TERMINAL. Digital Indicators. Product Number 3020

Extruder Controls ExtruVision S

NAVIGATOR. Digital Weight Indicator. Completely Menu-Driven Set-up Navigation. Bulletin No. 330D. Cardinal Scale Model 225 Weight Indicator

PUE C/31 measuring indicators PUE C/31H measuring indicators PUE C/31H/EX measuring indicators PUE C/41H measuring indicator...

DRAFT. Customer site gravity factor. Filtering parameters. Five points for linearity correction to ensure maximum accuracy

LAUREL ELECTRONICS, INC.

world class water monitoring series 42

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

PUE C/31 measuring indicators PUE C/31H measuring indicators PUE C/31H/EX measuring indicators PUE C41H measuring indicator...

Installation and User Manual. version 1.00 MODWF 2014/53/UE EN : /30/UE EN55022:2010 EN :2005 EN :2007

MCX08M2 Programmable controller

West Instruments. The MLC compact multi-loop controller... MLC ends the control or integration compromise

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

T1-Profinet-IO. 4-20mA 0-20mA 0-10V 0-5V +/-5V +/-10V 2014/30/EU EN55022:2010 EN :2005 EN :2007

enod products range Digital process controllers

Vibration-Resistant Weighing Indicator

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

Multi-Point Gas Detection and Control System

Defender Multifunctional Bench Scale for Standard Industrial Applications. Washdown Bench Scales. Standard Features:

SX90 Process Controller

Multi-Point Gas Detection and Control System

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

PTU300 Combined Pressure, Humidity and Temperature Transmitter

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

IDe 550 Indicator. Description. Plan

ATV930D22M3 variable speed drive - ATV930-22kW - 200/240V- with braking unit - IP21

COMTRAXX COM460IP. BMS-Ethernet-Gateway

COMMUNICATION PROTOCOLS

Weighing Electronics SIWAREX - PLC-based weighing electronics

E1205 advanced multi-function indicator

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Weighing Indicator. Features. Description. Applications

E1110 multi-function weight indicator

Multi-Point Gas Detection and Control System

Power Panel Integrated control, operation and visualization

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

LCp-100 Weight Indicator/Transmitter

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

Transcription:

Digital/analog weight transmitter suitable for back panel mounting on Omega/DIN rail or junction box for eld mounting (on request box versions). Weighing system with 8 independent reading channels with display of the total weight. The TLM8 transmitter allows to have same bene ts and performance of an advanced digital weighing system even using analog load cells. Dimensions: 148x92x60 mm. Backlit graphic LCD display, transmissive STN, white on blue, 128x64 pixel resolution, 60x32 mm visible area. Five-key keypad for the system calibration. TEST key for direct access to the diagnostic functions. Extractable screw terminal boards. IP67 VERSION BOX (on request) INPUT/OUTPUT Current or voltage 16 bit analog output RS485 serial port for communication via ModBus RTU protocol, ASCII Laumas bidirectional or continuous one way transmission. 5 relay digital outputs controlled by the setpoint values or via protocols. 3 optoisolated PNP digital inputs: status reading via serial communication protocols. 8 load cell dedicated inputs. 8+3 PG9 cable glands-plugs 8+3 PVC ttings for sheath FIELDBUSES 2016.12.05 TLM8den.cdr

RS485 port Baud rate: 2400, 4800, 9600, 19200, 38400, 115200 (bit/s). 16 bit analog output = 65535 divisions Current: 0 20 ma; 4 20 ma (up to 400 Ω). Voltage: 0 10 V; 0 5 V (min 2 k Ω) CANopen port Baud rate: 10, 20, 25, 50, 100, 125, 250, 500, 800, 1000 (kbit/s). The instrument operates as slave in a synchronous CANopen network. CODE TLM8 TLM8CANOPEN DeviceNet port + RS485 + Analog output Baud rate: 125, 250, 500 (kbit/s). The instrument operates as slave in a DeviceNet network. TLM8DEVICENET CC-LINK port + RS485 + Analog output Baud rate: 156, 625, 2500, 5000, 10000 (kbit/s). The instrument works as Remote Device Station in a CC-LINK network and occupies 3 stations. TLM8CCLINK PROFIBUS DP port + RS485 + Analog output Baud rate: up to 12 (Mbit/s). The instrument operates as slave in a Pro bus-dp network. TLM8PROFIBUS Modbus/TCP port + RS485 + Analog output The instrument operates as slave in a Modbus/TCP network. Ethernet TCP/IP port + RS485 + Analog output. The instrument operates as slave in an Ethernet TCP/IP network and it is accessible via web browser. Ethernet/IP port + RS485 + Analog output he instrument operates as adapter in an Ethernet/IP network. TLM8MODBUSTCP TLM8ETHETCP TLM8ETHEIP PROFINET IO ports + RS485 + Analog output The instrument operates as device in a Pro net IO network. TLM8PROFINETIO 2x EtherCAT ports + RS485 + Analog output The instrument operates as slave in an EtherCAT network. TLM8ETHERCAT 2x POWERLINK ports + RS485 + Analog output The instrument operates as slave in a Powerlink network. TLM8POWERLINK 2x SERCOS III ports + RS485 + Analog output The instrument operates as slave in a Sercos III network. TLM8SERCOS

TLB4 WEIGHT TRANSMITTER - 4 INDEPENDENT CHANNELS CERTIFICATIONS μv/vsi OIML R76:2006, III class, 3x10000 divisions 0.2 CERTIFICATIONS ON REQUEST Initial veri cation (Legal Metrology) UL Recognized component - Complies with the United States and Canada regulations Complies with the Eurasian Custom Union regulations (Russia, Belarus, Kazakhstan) TECHNICAL FEATURES Power supply and consumption 12 24 VDC ±10%; 5 W Number of load cells Load cells supply Ω) - 4/6 wires 5 VDC/240 up to ma 16 (350 Linearity Linearity of the analog output <0.01% full scale <0.01% full scale Thermal drift Thermal drift of the analog output <0.0005% full scale/ C <0.003% full scale/ C A/D Converter 8 channels - 24 bit (16000000 points) - 4.8 khz Divisions (with measure range ±10 mv and sensitivity 2 mv/v) ±999999 0,01 μv/d Measure range ±39 mv Load cell s sensitivity ±7 mv/v Conversion per second 600/s Display range ±999999 Decimals Display increments 0 4 x1 x2 x5 x10 x20 x50 x100 Digital lter Conversion rate 0.006 7 s 5 600 Hz Relay logic outputs n. 5-115 VAC/150 ma Optoisolated logic inputs n. 3-5 24 VDC PNP Serial ports RS485 Baud rate 2400, 4800, 9600, 19200, 38400, 115200 (bit/s) 16 bit = 65535 divisions. 0 20 ma; 4 20 ma (up to 400 Ω) Analog output 0 10 V; 0 5 V (min 2 k Ω) Humidity (condensate free) 85% Storage temperature -30 C +80 C -20 C +60 C Relay digital outputs n. 5-30 VAC, 60 VDC/150 ma -20 C +50 C Power supply device marked LPS (limited power source) or Class 2 METROLOGICAL SPECIFICATIONS OF TYPE-APPROVED INSTRUMENTS Applied standards Accuracy class Maximum number of scale veri cation divisions Minimum input signal for scale veri cation division 2014/31/UE - EN45501:2015 - OIML R76:2006 III or IIII 10000 (class III); 1000 (class IIII) 0.2 μv/vsi -10 C +40 C

TLB4 WEIGHT TRANSMITTER - 4 INDEPENDENT CHANNELS MAIN FUNCTIONS 8 independent channels for load cells: monitoring and direct management of the individual load cells connected. Digital equalization: the instrument allows to equalize the connected load cells response, in a fast and reliable over time. Load distribution synoptic analysis on 8 channels with archive backups: storing, retrieving, printing. Automatic diagnostics: the instrument is designed to store the percentage value of load distribution for each channel. The diagnostic function makes comparisons between the recorded values and if a signi cant variation between the values is detected during normal operation, the instrument displays an alarm alternating with the weight value. Depending on the weighing system type it s possible to perform: - Load automatic diagnostics: load distribution control in constant barycentre systems (e.g. liquids silo). - Automatic diagnostics on zero: check on load cells drift state (eg. silo, weighbridge, platformes). Event log: data backups archive in chronological order of the last 50 events related to calibrations, zero settings, errors and equalizations. The information can be stored, retrieved and printed. All TLM8 functions can be managed by a weight indicator W series connected via RS485 serial port (excluding indicators with graphic display). Transmission of the divisions for the 8 independent reading channels via RS485 (Modbus RTU) or eldbus. Only the points of each load cell connected are transmitted, without any lter applied; the calculation of the weight value, the zero setting and calibration are performed by the customer. Connections to: - PLC via analog output. - PC/PLC via eldbus. - PC/PLC via RS485 (up to 99 instruments with line repeaters, up to 32 without line repeaters). - W series weight indicator via RS485. - remote display and printer via RS485. - max. 16 load cells in parallel. Digital lter to reduce the effects of weight oscillation. Theoretical calibration (via keyboard) and real (with sample weights and the possibility of weight linearization up to 5 points). Tare weight zero setting. Automatic zero setting at power-on. Gross weight zero tracking. Semi-automatic tare (net/gross weight) and predetermined tare. Semi-automatic zero. Direct connection between RS485 and RS232 without converter. Hysteresis and setpoint value setting. TCP/IP WEB APP Integrated software in combination with Ethernet TCP/IP version, for supervision, management and remote control of the weight transmitter. CE-M version: 2014/31/EU-EN45501:2015-OIML R76:2006 Weight subdivisions displaying (1/10 e). Three operation mode: single interval or multiple ranges (max 3) or multi-interval (max 3). Net weight zero tracking. Calibration correction via keyboard is protected through seals for the access to a setting jumper or installer password or hardware device. Alibi memory (option on request). 8 INDEPENDENT CHANNELS The screen shows the automatic standard operating mode and the activation/deactivation status of individual channels to indicate the presence/ absence of connection with load cells. Auto mode: at each power-on, the instrument automatically detects the status of the 8 channels. Active Channels: there is a connection with the load cell. Channel not active: no connection with the load cell. LOAD DISTRIBUTION The TLM8 displays graphically the current load distribution on each active channel. Gross weight % of distributed load Channels Bar chart Current state OFF Channel not active ERROR Connection problem The TLM8 displays graphically the load cells response signal in mv for each active channel.

TCP/IP TCP/IPWEB WEBAPP EQUALIZATION WITH JUNCTION BOXES The equalization procedure with junction boxes and trimmer requires more manual steps and over time it can undergo drift phenomena over time, requiring subsequent repetitions of the same procedure. = LOAD CELLS 998 kg 1002 kg TRANSMITTER INDICATOR EQUALIZATION BOARD kg 1000 PLATEFORM 997 kg 1003 kg DIGITAL EQUALIZATION The TLM8 does not require the use of junction box, thanks to the support of 8 independent channels; furthermore the digital equalizer function simpli es the procedure to a single step and it is free of drift over time. TLM8 kg 1000 PLATEFORM OPTIONS ON REQUEST CODE Alibi memory OPZWALIBI IP67 ABS waterproof box 190x190x130 mm (4 xing holes Ø4 mm; centre distance164x164 mm) - transparent cover - transparent cover; 8+3 PG9 cable glands-plugs - transparent cover; 8+3 PVC ttings for sheath - external keyboard - external keyboard; 8+3 PG9 cable glands-plugs - external keyboard; 8+3 PVC ttings for sheath CASTLG CASTLG8PG9 CASTLG8GUA CASTLGTAST CASTLGTAST8PG9 CASTLGTAST8GUA The Company reserves the right to make changes to the technical data, drawings and images without notice.