PDS200 Power over Ethernet Device Server User Manual

Similar documents
1 port RS-232 Device Server

Document Name: User Manual for SC10EK4 Serial to Ethernet Converter with 4 TCP Sockets. Index

RS232+LAN INTERFACE USER MANUAL

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

DSEEXTRA. DSE860 RS232 Ethernet Adaptor DSE865 RS485 Ethernet Adaptor Document Number Author : Anthony Manton

Tibbo Ethernet-to-Serial Devices: Hardware, Firmware, PC software

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL

TRP-C37 User s Manual

User Manual A08. User Manual

TRP-C37. Ethernet to RS232/422/485 Converter. User s Manual. Printed Apr.2014 Rev 1.3

Industrial Serial Device Server

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

TRP-C37M User s Manual

RS232/RS485/RS422 to TCP/IP Converter ITEM NO.: RS007

TRP-C37. Ethernet to RS232/422/485 Converter. User s Manual. Printed September Rev 1.6

Ethernet Serial Server

Ethernet Interface Module

MSD-SRF2XM Multi-port RS-232 to Ethernet Data Gateway User Manual

Lantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual

Communication adapter RS485/422 over the Ethernet ELO E222. User manual

CHIYU. Product Specification BF-450(M)/BF-430. RS232/RS485/RS422 To TCP/IP Converter Module. Release 1.0

INDEX. Document Name : User Manual for SC10EJ Serial to Ethernet Converter

Serial to Ethernet Converter HL-SE02P-V1. User s Manual V3.606

EX-6014WI RS232 to WiFi Wireless Adapter, w/ Mounting Kit

ACE PLUS CORP. APCON100 series Operation Manual RS-232 to Ethernet Converter

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

Operation Manual of EX9132CST-Series

LM300 Manager User Manual. Document Version: 1.1 LM300 Firmware Version: Bluetooth Firmware Version:

HOME AUTOMATION, INC. Model 93A00-1. Serial Server. User s Manual

DGH A3000 Configuration Guide For use with DGH Modules

Instruction for configuring and using RS-LAN

TRP-C37M User s Manual

Serial to Ethernet Converter

Key Features. Protocol and application

NetCom 413 PRO. Contact Online. More Pictures. Klick on the thumbnails for the large picture. Overview

e-net TCP/IP Converters

Communication adapter RS232 over the Wi-Fi ELO E231. User manual

Poseidon 4002 MANUAL

USER S MANUAL. PH485Ex1. #1 RS-485 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH485Ex1-UM-001 IPEX. (IP Electronix)

STE100A Single Port IP to Serial Device Server

SSE232-LE Serial Server- User s Manual

Infosystem. User Manual. Version 1.0. Serial to Ethernet Converter with 3 sockets. Infosystem Technology Corporation, Ltd.

SERIAL TO ETHERNET CONVERTER E-P User Manual

NordField Electronics

WIZ107SR User Manual

Quick Start Guide. 2-Port 10/100 Device Server RS-232/422/485 DB9 M. Access two serial RS-232 or RS-422/485 devices over a 10- or 100-Mbps network.

Quick Start Installation Guide

Embedded Modbus TCP Module GS11-MT. User Manual REV 1.1. SST Automation.

Conettix ITS-D6686-INTL

TRP-C34H. Ethernet to 4 RS232/422/485 Converter. User s Manual. Printed Sep Rev 1.1

Manual Documentation Number: ESR90x-5012m B&B Electronics Mfg Co Inc 707 Dayton Rd - Ottawa IL Ph Fax

JetBox 9300/9310 User Manual. Hardware

TCP/IP Converter. EX-9132 Operation Manual for 8051 Series

Getting Started Guide for the Remote Access Dial-in Ethernet Modem 9300-RADES

RN-174 WiFly Super Module

ECOV-110 User s Manual

L Port 10/100/1000T PoE + 2-Port Gigabit SFP + Managed Switch

Canlan INSTALLATION MANUAL

XT - NANO - SXL XT-NANO-SXL

IDS-141A/181A. Industrial 4-port/8-port slim type serial to Ethernet device server. Features. Introduction. DS-Tool

DT Desktop Series

Installation and Configuration Guide

NET101. RS232 / RS422 / RS485 to Ethernet Converter. User s Manual. Version 1.2

Industrial Device Server User s Manual

User Manual. NetCom Lite. Edition: January 2012

5600 Series. 8 and 16-port Serial Device Servers. Features. Internet Readiness for up to 16 Serial Devices

LM300 Bluetooth Ethernet Access Point/ Server 3 simultaneous Bluetooth SPP connections

Conettix ITS-D6682-INTL

Quick Start Guide. 8-Port Value-Line Console Server QS Guide LES1508A

Tel: Fax:

NetCom Plus 413 POE. Contact Online. More Pictures. Click on the thumbnails for the large picture. Overview

VG422R. User s Manual. Rev , 5

ES-446 PoE ETHERNET TO SERIAL DEVICE SERVER Ethernet 1 Port RS232 Power Over Ethernet PoE CONNECT, CONFIGURE, CONTROL YOUR SERIAL DEVICES.

Industrial Device Server IDS-3010 Fiber Series

Ethernet to Serial Port Module RS-232/422/485 to Internet Gateway

IP7 EDx/ESx. Intercom. Reference Manual

Operation Manual EX-9133C-2-MTCP

PoE Splitter. Ordering Information: POE SP D N

ZAC Product Specification

RN-174. WiFly GSX Super Module. Features. Description. Applications. rn-174-ds v1.1 1/24/2011

MESR Port Industrial Modbus Gateway. Specifications Power. MESR424_r000_2913ds

MGate TM EIP3000 DF1 to EtherNet/IP Gateway User s Manual

ETH to 232 (A) User Manual

Operation Manual of EX-9132C-2. Serial to TCP/IP Converter

Tibbo. EM100 Ethernet Module (EM100SK Starter Kit) Technical Manual* Tibbo. Thank you for taking an interest in Tibbo s Products!

Conettix ITS-D6686-UL PRELIMINARY. Installation Guide. Ethernet Network Adapter

Conettix ITS-D6686-UL

RS-232/422/485 Over IP Adapter

The specifications for the Cisco 7304 router are listed in Table A-1.

ES-511, ES-522, ES-551, ES-571. Quick Start Guide. for Brainboxes Ethernet to Serial Range

RX3041. User's Manual

ABLELink. Modbus Gateway MB5000 Series User s Manual

ES-413 PoE ETHERNET TO SERIAL DEVICE SERVER Ethernet 2 Port RS422/485 Power Over Ethernet PoE CONNECT, CONFIGURE, CONTROL YOUR SERIAL DEVICES

International Headquarters. European Headquarters

Features. Preliminary. Industrial IEEE b/g/n with 2x10/100Base-T(X) 1x RS-232/422/485 IoT LTE LPWAN Gateway. Introduction

TK C -25 C 95% RH EMC TK701G TK701U TK704G TK704U TK704W. TK-Series Cellular Router

International Headquarters. European Headquarters

SerialGate. User Guide. Version: 2.1e

SERIAL TO WiFi CONVERTER EX-9486C-W User Manual

Transcription:

PDS200 Power over Ethernet Device Server User Manual ABOUT PDS200 is an external usage Power over Ethernet Device Server (Serial-to- Ethernet converter). It includes the function of GIGA-TMS s products- DS203 (Device Server) and PS200 (Power over Ethernet Splitter). It can connect existing serial device (RS232 or RS485) to Ethernet network and supplies DC12V or DC5V output for the serial device (RS232 or RS485). It has RS232 and RS485 serial ports. You can set the output signal to RS232 or RS485 by adjusting the DIP Switch that located at the bottom case of PDS200. The product offers a compact disk which includes Tibbo Device Server Toolkit software and Virtual Serial Port driver for Windows and Linux. To manipulate Ethernet and serial s settings, please refer to Tibbo Device Server Toolkit Documentation. APPLICATION For those areas that AC power is not available, PDS200 provides the easiest way to power Ethernet device (supply DC12V or DC5V power). The hardware of PDS200 includes an Auto-MDIX* 10/100BaseT Ethernet port, a RS232 serial port, a RS485 serial port and an internal processor that "glues" network and serial sides together. From the hardware standpoint, PDS200 can be regarded as a universal platform that is suitable to run a variety of network and serial communication applications. Most functions of PSD200 are provided by Application Firmware. PDS200 runs in Application Firmware ("Serial-to-Ethernet" mode) that turns the PDS200 into a ready-to-work serial-to-ethernet converter that can connect almost any kind of serial device to Ethernet (TCP/IP) network. Application Firmware has fixed function. If you want to adjust the behavior of PDS200, you can specify the values of programmable parameters (settings) defined in this firmware. In addition, Application Firmware of PDS200 can be upgraded and firmware upgrade is via serial port or Ethernet port. Serial upgrade is facilitated by a so-called Monitor- a fixed "service" firmware inside the PDS200. Network upgrade relies on the Application Firmware itself - there is a self upgrade algorithm with Tibbo Device Server Toolkit software. * Auto-MDIX means automatic detection of "straight" and "cross" cables. FUNCTIONALITY DC12V or DC5V output for RS232 or RS485 device Full- and half-duplex serial port modes. Server, Client, and Server/Client network ("routing") modes. Numerous options for connection, serial port, etc. 8KB data buffers (one in each direction). Configuration stored in EEPROM. Setup through the serial port or network (UDP, Telnet). Remote control of RTS, CTS, DTR, and DSR lines. "On-the-fly" commands for immediate serial port configuration.

Serial-side "modem" commands for network connection control. Direct control of ADSL modem. Support UDP, TCP, ARP, ICMP (ping), DHCP, PPPoE, LCP. SPECIFICATIONS Product Model IEEE802.3af Compliant 2 Pair/4 Pair Power Extraction Ethernet Connector RS232 Connector RS485 Connector DC 12V Output (DC Jack) DC 5V Output (4P connector) Number of Device Can be Powered Ethernet Cable LED Indicator Dimensions Weight Operating Environment Storage Environment IEEE 802.3af Power over Ethernet Device Server (Serial-to-Ethernet Converter) PDS200 Compliant to all IEEE 802.3af specifications. Present class 0 PD to PSE. Extract power from data pair (1,2,3,6), spare pair (4,5,7,8) or both pairs. PoE signature on any one pair. RJ-45 (PoE in), 10/100BaseT, auto-mdix Ethernet port RS232 mode: RX, TX, RTS, CTS, DTR, DSR lines Default settings: 19200-N-8-1 (DIP Switch all OFF) RS485 mode: RX+/-, TX+/-, automatic direction control; Default settings: 19200-N-8-1 (DIP Switch all ON) 12VDC, 660mA (Max.); 5VDC, 240mA (Max.), *internal circuit used partial power 1 TIA/EIA-568, Category 5/5e cable Yellow - PoE working normally and 12VDC ready. Red - DS operation under the error mode. Green - Network working normally. 100(L) * 98 (W) * 21(H) mm 150g 0~50 Degree C, 5%~90% RH -10~70 Degree C, 5%~90% RH Ethernet Port Pin Assignment & RS232/485 Port Pin Assignment PoE IN RS232/485 Port 8 1 #1 #1 No #1 +5V TX+ connection #2 TX- #2 RS-RX #2 R+/T+ #3 RX+ #3 RS-TX #3 R-/T- #4 #4 RS-DTR #4 GND SP+ #5 #5 GND #6 RX- #6 RS-DSR #7 #7 RS-RTS SP- #8 #8 RS-CTS #9 No connection The mark "DC12V Out" on the right figure is output Power Jack.

Ethernet Port Pin Assignment Ethernet port of PDS200 is 10/100BaseT type. Connector is RJ45 type. The following is pin assignment: #1 TX+ #2 TX- #3 RX+ #4 #5 SP+ #6 RX- #7 #8 SP- RS232 Port Pin Assignment DB9M RS232 connector has the following pin assignment: #1 <No connection> #2 RX (input) #3 TX (output) #4 DTR (output) #5 Ground #6 DSR (input) #7 RTS (output) #8 CTS (input) #9 <No connection>

RS485 Port Pin Assignment RS485 connector has the following pin assignment: T+ pin (#2) is RS485 positive differential-signal (T+/R+), T- pin (#3) is RS485 negative differential-signal (T-/R-). DC 5V Output (4P Connector) The RS485 connector also supplies DC 5V power output: Output (5V) pin (#1) correspond to ground (GND) pin (#4) is DC5V output port, this power can supply for RS232 or RS485 device which uses DC5V power source. The DC5V tolerance range is 4.75VDC ~ 5.25VDC, and maximum output current is 240mA. GIGA-TMS supplies a power cable WAS-T0471. This cable originally is used for DC12V output. If RS232 or RS485 device does not use DC12V power source, you can use WAS-T0471 as DC5V output cable by cutting the B end of WAS-T0471 and then peeling the black cover of WAS-WT0471 around 2.0 cm and peeling the covers of inner red and white wires around 0.5 cm as the pictures below. Then connect the red wire to output (5V) pin (#1) and connect the white wire to the ground (GND) pin (#4). DC5V will be output from the A end of WAS-T0471 for Serial Device usage. WAS-T0471 WAS-T0471 with black cover 1.5 cm 0.5 cm Red wire White wire

DC 12V Output (DC Jack) The DC jack of PDS200 accepts "small" power connector with 3.5mm diameter. It outputs DC12V power for RS232 or RS485 device. Please use WAS-T0471 power cable that supplied by GIGA-TMS. Output power tolerance range is 11.4VDC ~ 12.6VDC and maximum output current is 660mA. On the DC jack, the ground is "the outside" circle, shown on the figure as below. DIP Switch setting for RS485 communication The DIP Switch is located at the bottom case of PDS200. All DIP Switch set to ON position indicates that data is routed through PDS200 via RS485 port. DIP Switch setting for RS232 communication The DIP Switch is located at the bottom case of PDS200. All DIP Switch set to OFF position indicates that data is routed through PDS200 via RS232 port.

Status LEDs PDS200 (PoE Device Server) features one Power Status LED (yellow LED) and two Status LEDs (red LED and green LED). Yellow LED means that PoE function works normally and 12VDC is ready. Red LED and green LED display various states of device operation. The states of PDS200 are indicated by way of playing "LED patterns". Patterns are represented by graphics in the following manner: The pattern means that both red LED and green LED blink three times together. The pattern means that red LED makes one long blink and then two short ones.

Status LEDs (red LED and green LED) display various status information depending on what firmware is running at the moment. Follow the descriptions below to learn more about the behavior of these LEDs under different conditions: Status LED behavior in Application Firmware Powerup pattern. This pattern is played once when the PDS200 is switched on. Buzz pattern. Both LEDs blink fast- this pattern is played when the PDS200 receives the Buzz (B) command. This is used to identify a particular PDS200. Status LEDs of the PDS200 are playing a serial programming mode pattern when the serial port of the PDS200 is in the serial programming mode. Status LEDs of the PDS200 are playing an error mode pattern when the PDS200 is in the error mode (unless the serial port of the PDS200 is in the serial programming mode). Ethernet Port failure. Indicates that the Ethernet port hardware is malfunctioning and network communications with the PDS200 is not possible. IP-address not obtained. Occurs at startup when DHCP (DH) setting is 1 (enabled) and the PDS200 has not yet obtained its IP-address from the DHCP server. PPPoE login failed. Occurs at startup and means that either PPPoE login name and password (defined by PPPoE Login Name (PL) and PPPoE Login Password (PD) settings) are incorrect or PAP authentication protocol used by the PDS200 is not supported by Access Concentrator. Data connection is closed. This pattern means that no data connection (TCP or UDP) with any network host is currently established so the PDS200 is idle. Sending ARP. Displayed when the PDS200 is sending ARP requests to find out MAC-address of the destination network host with which the PDS200 is about to establish a connection. TCP connection is being opened. Indicates that TCP connection (either incoming or outgoing) is being established (i.e. SYN-SYN- ACK exchange is in progress). TCP connection reset (rejected) by the network host. Means that the TCP connection has been reset (using RST packet) by the network host to which the PDS200 has tried to connect. Link Server login in progress. Means that the PDS200 has already established TCP connection to the Link Server and is now attempting to login. Link Server login failed. Means that data connection to the Link Server could be

established but the server has rejected this PDS200 (because the data in the Owner Name (ON), Device Name (DN), or Password (PW) setting is incorrect or for some other reason). Data connection is established or being closed. Means that data UDP "connection"or TCP connection is currently established or that TCP connection is being closed (i.e. FIN- ACK-FIN-ACK exchange is in progress). Data is being routed, no overruns detected. This pattern is played when the data connection is established and the data is being routed through the PDS200. Buffer overrun, no data routing. This pattern is displayed when the data connection is established and the routing buffer overrun has been detected (within the present data connection). Buffer overrun + data routing. Data routing and overrun can be displayed at the same time. Status LED behavior in Monitor Firmware Fast-blinking pattern means that neither application firmware, nor the NetLoader can be found in the FLASH memory of the PDS200. The way out of this situation is to upload application firmware and the NetLoader into the device via its serial port. Slow-blinking Green Status LED means that the serial upgrade was completed successfully. Slow-blinking Red Status LED means that there was a timeout while waiting for the XMODEM data. If this happens right in the beginning of the serial upgrade then most probably this is caused by incorrect serial settings on the PC side, incorrect serial cable wiring, or incorrect XMODEM start procedure- XMODEM must be started on the PC first, and only then the DS is switched on (with he Setup button pressed; Note: Setup button is nearby EM203 module in the case). Communications error. This pattern means that an error was detected on the protocol level in XMODEM communications. Most often this means that incorrect communications parameters are set on the PC side. Firmware file is too big. This pattern means that the file you are trying to upload into the PDS200 is too big. Check if you have selected a correct file. FLASH failure. This pattern means that internal FLASH memory of the PDS200 is malfunctioning. Note: Please refer to Device Server Toolkit (DST) software for Windows under item Software Manuals in HTML Help file- sois_manual in CD for more detail description about software- DS Manager, VSP Manager, and Connection Wizard.