Mains Monitoring Instruments 4

Similar documents
UMG 511. Class A EN UMG 511 Class A power quality analyzer. according to EN50160, IEEE 519, ITIC, IEC Areas of application

PQM - Power Quality Monitoring

ENERGY MANAGEMENT Table of Contents

UMG 605. UMG 605 power quality analyzer (EN 50160, IEEE 519, ITIC)

UMG 604. UMG 604 Power analyser. Modbus master, Ethernet gateway. Harmonics. Memory 128 MByte. Homepage. Graphic programming.

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

Smart Energy & Power Quality Solutions. UMG 507 Power analyser

PQM - Power Quality Monitoring

MIC-2 MKII, Multi-instrument DATA SHEET

PQM - Power Quality Monitoring

UMG 96RM. UMG 96RM Universal measurement instrument. Areas of application

U niversal Measuring Device UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs. Digital I/O

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

UMG 605. UMG 605 Power quality analysers for DIN rails. Flicker. Reporting. Memory 128 MByte.

MIC-2 Multi-instrument DATA SHEET

DATA SHEET LAN Server For Energy and Power meters AEM and APM with Modbus interface

EMIS Central Unit. System Components. Central Unit

PQM - Power Quality Monitoring

UMG 511. Class A power quality analyser. Reporting Homepage

U niversal Measuring Device NEW! UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs.

Smart Energy & Power Quality Solutions. UMG 505 Power analysis, LON and I/O-Vielfalt

POWER SIMPLY SAVE. Catalogue Catalogue 2017

PQM 1588 Power Quality Manager

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

Smart Energy & Power Quality Solutions. UMG 96S Universal flush-mounting measuring instrument

Increase transparency and process quality Total Energy Monitoring across all levels of production Let s connect. Measuring and monitoring systems

PQM 1588 Power Quality Manager

A2000 Multifunctional Power Meter

COMTRAXX COM460IP. BMS-Ethernet-Gateway

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

E 1. SPECOM - Network analyser. Content. E.2 Description. E.3 Specom C - Technical data. E.4 Specom M - Technical data. E.5 Data communication

EngyVolt RV12 and RV15

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM

Transienten. Datenspeicher

6-Channel power analyser UMG 96RM-E. Operating current and RCM fault current monitoring. Smart Energy & Power Quality Solutions RCM.

FOUR FUNCTIONS ONE SOLUTION

BMS-Ethernet-Gateway COM460IP

UMG 20CM. UMG 20CM 20 Channel Branch Circuit Monitoring Device with RCM. Harmonics via analysis channel RCM. Alarm management.

Power and accuracy. Versatile. One display can monitor up to 32 measuring modules information

DIRIS A-30 Multifunction power metering & monitoring device - PMD

THE NEXT TRANSDUCER GENERATION

Digital Multifunction Meters. Digital Multifunction Meters

Technical data sheet. PowerLogic power-monitoring units EM3500 series DIN Rail meter

Energy meters Single phase electrical energy meters WM1-6 / WM1M6

INTEGRA DIGITAL METERING SYSTEMS

DATA SHEET. Advanced Power Meter, APM 380 & APM 305

DIRIS A. Multifunction measurement units for managing your electrical networks

WM20. Power analyzer for three-phase systems. Benefits. Description

with Backlight Graphic LCD Screen

LSFC Power Factor Correction Systems

Smart Energy & Power Quality Solutions. UMG 103-CBM energy meter with memory COMPACT, BEST-PRICED & SAFETY

USER MANUAL 2012 V1.1

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

Three-phase electricity meter with instantaneous reading of electrical variables. Input current measurement: 5 A, 90 A, 150 A, 250 A (span by model).

Multifunction Transducer MT440

Smart Energy & Power Quality Solutions UMG 96RM. Multifunction power analyser

Voltage Transducer UMT516 / MT516

Electrical multifunction analysers

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

COMTRAXX COM465DP. Condition Monitor with integrated gateway for the connection of Bender devices to PROFIBUS DP and Ethernet TCP/IP networks

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

COMTRAXX COM465IP. Condition Monitor with integrated gateway for the connection of Bender devices to Ethernet TCP/IP networks

Setting up an EM System

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

Power Meter PowerMonitor 500

POWER MEASUREMENT IN ELECTRICAL SYSTEMS SIRAX MONITOR SERIES BUILT-IN DEVICES FOR MEASUREMENT IN POWER SYSTEMS

Rapidus Power Factor Controller

Energy Management Modular Energy meters Type EM2-96

1/2 Description XV400 Flexible in Application

DATA SHEET. Advanced Energy Meter, AEM 380 & AEM 305

SUBJECT TO CHANGE WITHOUT NOTICE

SDM630M CT USER MANUAL 2016 V4.7. DIN Rail Energy Meter for Single and Three Phase Electrical Systems

METERING INSTRUMENTS AND CURRENT TRANSFORMERS

Power Energy Analyser & Logic Controller Maximum Demand Load Shed Controller 2nd - 40th Voltage & Current Harmonic Analyser

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

PLC PFC200 Controller PFC200 CS 2ETH RS

DIRIS Digiware D and C Communication and control power interfaces

PROFITEST PV Peak Power Measuring Instrument and Curve Tracer for PV Modules and Strings (Measurement at Capacitive Load)

COMTRAXX COM465IP. Condition Monitor with integrated gateway for the connection of Bender devices to Ethernet TCP/IP networks

FLEXIBLE SOLUTIONS FOR THE ENERGY INDUSTRY

PRELIMINARY. USB1 / USB2 USB host interface to read data via memory stick. Bus Out (system bus) For connection to a router

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

Smart Energy & Power Quality Solutions. UMG 96RM-PN The communications professional. Multifunctional power measurement device with PROFINET interface

4 Is this model available for special primary current and special primary voltage?

COMTRAXX COM465IP. Condition Monitor with integrated gateway for the connection of Bender devices to Ethernet TCP/IP networks

May Delivers real-time, Web-enabled monitoring of electrical distribution and control equipment

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

PowerPad III Model 8336

B+G E-Tech User Manual for SDM630 SDM630. Din Rail Smart Energy Meter for Single and Three Phase Electrical Systems USER MANUAL 2013 V1.

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

AcquiSuite Ally 48 Advanced Branch Circuit Monitor

NP40 - PORTABLE POWER QUALITY ANALYZER FEATURES

Energy Management Modular Universal Utility Meter and Power Analyzer Type WM24-96

metrum PQ 110 Power Quality Unit, Class A Normative reference instrument for MV substation monitoring

Index 12 CVM R8A-C / CVM R8A-D 12 CVM R10-C

EM6400 series Multi-Function meters

SB2WEB24. SB2WEB BACnet Controller. Benefits. Description

You can find us everywhere.

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

PowerLogic EM4000 series

Transcription:

The power quality of the electrical supply networks plays an increasingly important role for the operational safety of electrical installations and equipment. Therefore it becomes more and more important to take appropriate measures to monitor the power quality. In contrast to the past it is obvious that it is not sufficient to do a single measurement and then disregard the mains quality if the measurement showed unproblematic values. Due to complex production processes, changing load conditions and a steady progress in the degree of automation it became important to permanently monitor the quality of electrical power supply. Thus one can acquire energy know-how and define critical values for measurement variables such as voltage, current and harmonics. Automatic alarms via different information channels such as e-mail, SMS, warning lights, etc. allow the control of compliance with the now specified critical values. Of course, critical values predefined by standards and regulations can also be signalled via these channels. FRAKO Mains Monitoring devices can handle all these operations. Depending on type and version this can be achieved already by a single device or even better - in combination with the FRAKO Energy Management System. Monitoring of transformers, measurements at low voltage distribution boards as well as monitoring of individual machines and consumers. FRAKO has the solution for every application. Subject to technical changes / FRAKO GmbH / www.frako.com Main Catalogue 2016 - PQ 221

EM-PQ 3000 EM-PQ 2500 EMA 1101 EMA 196 110-00 V AC Voltage 95-20 V AC; 95-20 V AC; (max. 99-0 V AC) or 230 V AC ± 10 % 80-30 V DC ± 10 % 80-30 V DC ± 10 % 120-350 V DC (max. 96-20 V DC) Frequency 5/65 Hz 5/65 Hz 8...62 Hz 5...66 Hz Power consumption Max. 9 VA Max. 9 VA Max. 7 VA Max. 5 VA Contact termination / / - ; 2-wire and / / - / / - / / - 3//5-wire single phase 3 x X/5A Current measurement x X/1A, X/5A x X/1A, X/5A (Transformer current > 6 ma), inputs electrically isolated 3 x X/5A 3 x 250-550 V AC 3 x 100-289 V AC Voltage measurements (external/external (external/neutral 17/720 V AC (L-N/L-L) 17/720 V AC (L-N/L-L) conductor); conductor); 3-phase -wire system 3-phase -wire system 80 V AC (L-L) 3-phase 80 V AC (L-L) 3-phase 3 x 50-105 V AC 3 x 173-500 V AC 3-wire system 3-wire system (external/external (external/neutral conductor) conductor) Harmonics V/A 1-63 1-0 1-19 - Short term interruptions - - Active energy class 0.2 (.../5A) 0.2 (.../5A) 2 2 Analogue In-/Outputs - / - - / - 2 temperature / - - / - Digital In-/Outputs 8 / 5 8 / 5 Tariff input for selection of 2 profiles / 1 alarm signalling contact 250 V DC, max. 3 A - / optional Plug-In module for active or reactive power Memory Min./Max. values Memory size 256 MB 256 MB - - Interfaces Ethernet - - Connection via Connection via optional Plug-In module FRAKO Energy - Modbus RTU (RS-85) - Modbus RTU (RS-85) via FRAKO Starkstrombus enables the connection Management System or or via Modbus RTU - Modbus TCP (Ethernet) - Modbus TCP (Ethernet) RS-232 / RS-85 - / - / (optional for EMA 1101, EMA 1101 105 V) / - - / - Profibus DP (only -DP - versions) - Webserver / E-Mail - / - / - / - - / - Recommended applications Transformer / NA Transformer / NA Transformer / NA Load outgoing unit Catalogue Page Page 223 ff. Page 227 ff. Page 231 ff. Page 235 ff. 222 Main Catalogue 2016 - PQ Subject to technical changes / FRAKO GmbH / www.frako.com

EM-PQ 3000 Power Quality Analyzer Mains monitoring device class A for control panel installation to detect, monitor and analyze electrical measurement variables in mains up to 720 V (phase/phase) with current transformer inputs and voltage inputs. Direct connection to the FRAKO Energy Management System via integrated interfaces RS-85 (Modbus RTU) or Ethernet (Modbus TCP/IP). Description Measuring functions: Frequency of fundamental 15 Hz... 0 Hz Measuring intervals from 10/12 (50/60 Hz) periods (200 ms) Continuous scanning with 20 khz per channel and calculation of the following measurement readings: Voltage L-N, neutral point displacement voltage Voltage imbalance L1... L3 Voltage L-L Frequency (equally for all channels) Current, total current L1... L3, total current L1... L3+N Power (active, reactive, apparent power, power factor, distortion reactive power) Fundamental power (active, reactive, apparent power, cos phi, phase shift) Summation L1... L3 of the above mentioned performance values Summation L1... L (active, reactive, apparent power) Active power (regenerated and consumed) of the main and ancillary system Reactive power (capacitive and inductive) of the main and ancillary system Fourier analysis 1st... 63rd harmonic for current, voltage, active and reactive power as well as interharmonics for every single harmonics per phase Distortion factors (THD) of current and voltage TDD (Total Demand Distortion) L1, L2, L3 Current, short-term, long-term flicker Allocation of the measurement readings to generate protocols according to EN 50160, EN 61000-2-, power quality and costs report Detection and recording: Detection and recording of the minimum, maximum and average value of the measurement readings defined by the user as well as the acquisition periods for histograms of the parameterized time periods Detection of under- and overvoltages U rms Detection of voltage failures U rms Detection of inrush currents (10 ms) Detection of transients >50 microsec. Energy meter (active and reactive power, regenerated and consumed) with 8 tariffs Internal data storage: 256 MB Flash memory Subject to technical changes / FRAKO GmbH / www.frako.com Main Catalogue 2016 - PQ 223

Device equipment: Active matrix display (TFT B x H: 115 x 88 mm), Resolution (Pixel): 320 x 20, Brightness (cd/m 2 ): 300, Screen diagonal: 5.7 inch Embedded Webserver Technical Data Inputs: voltage measurement inputs current measurement inputs../1/5a 8 digital inputs: e. g. to change the tariffs, for external synchronisation and to release the records, pulse meter for external consumption meters 5 digital outputs, can also be programmed as a pulse or signal output Interfaces / Protocols: RS-85, Protocol: Modbus RTU/Master and Slave for connecting with the FRAKO Energy Management System Interface Profibus DP V0, with gateway function Ethernet 10/100 TBase Modbus RTU Master/Slave for connecting with the FRAKO Energy Management System, Modbus-Gateway, BACnet / IP or MSTP (optional) All interfaces run simultaneously Protocols: Modbus TCP/IP (Port 502), Modbus over TCP/IP (Port 8000), HTTP, SMTP, SNMP, SNTP, TFTP, FTP, DHCP Built-in homepage for remote maintenance and diagnostics with open structure for application-specific adjustment User programmable e-mail dispatch, e.g. in case of an alarm Supports HTML pages, Java Applets, Flash MX and ActiveX Configuration and visualization software EM-PQ VIS: Readout and visualization of measurement readings Automatic ring buffer down load of the devices Storage of data in a Derby database Optional: MS SQL and MySOL database drivers Graphical representation and analysis of online- and offline-measurement readings Freely configurable topology with freely selectable register levels Configuration of the measurement devices Parameterisation, visualization, data management, analysis Cost centre management Reporting function (EN 50160, voltage and cost centres) for freely definable time periods Statistics function Data export into a CSV file Possibility of customer specified programming (SPS-functionality) The following operating systems are supported: Microsoft Windows XP (Service Pack 3 or higher) Microsoft Windows Vista (Service Pack 1 or higher) Microsoft Windows 7, MAC OS (10.5 or higher), Linux and Unix Programming: Integrated Interpreter to create customized user programs, e.g. alarms, cost centre allocation, operating conditions,... Freely accessible internal variables (measurement readings...) via reloadable user programs 7 user programs can run at the same time Overvoltage category 600 V CAT III Rated voltage in Max. 17/720 V AC, +10 % -wire system Rated voltage in Max. 80 V AC, +10 % 3-wire system Frequency of 5-65 Hz auxiliary voltage Power consumption 15 VA Auxiliary voltage L-N 95...20 V AC; 80...30 V DC Power consumption 15 VA Current.../1A/5A measurement Minimum working 5 ma current Power consumption 0.2 VA Measurement Class A method and (according to IEC 61000--30) measurement precision Voltage ± 0.1 % Current ± 0.2 Power ± 0.2 % Active power Class 0.2S at.../5a Active power Class 0.5S at.../1a Reactive power Class 2 at.../1/5a Operational ambient -10 C...+55 C temperature Relative humidity 5 up to 95 % Ingress protection Front IP50, rear IP20 Dimensions 1 x 1 x 81 mm (W x H x D) Including Configuration and visualization software EM-PQ VIS Patch cable 3 m, (EM-PQ - Switch/Hub connection) Patch cable 2 m, cross-over (EM-PQ - PC connection) Fastening clamps Article-No. 29-20110 22 Main Catalogue 2016 - PQ Subject to technical changes / FRAKO GmbH / www.frako.com

Optional Accessories Article-No. Type Description 29-20112 Plug DB-9 WITH Terminal plug DB-9 bush (with screw terminals) termination 29-20113 Plug DB-9 WITHOUT Terminal plug DB-9 bush (with screw terminals) termination 29-2011 EM-PQ-VIS Configuration and visualisation software for Power Quality Monitor for EM-PQ 2100, 2200, 2500 and 3000 Dimensions Dimensional drawing EM-PQ 3000 All dimensions in mm Subject to technical changes / FRAKO GmbH / www.frako.com Main Catalogue 2016 - PQ 225

226 Main Catalogue 2016 - PQ Subject to technical changes / FRAKO GmbH / www.frako.com

EM-PQ 2500 Power Quality Analyzer Mains monitoring device for control panel installation to detect, monitor and analyze electrical measurement variables in mains up to 720 V (phase/phase) with current transformer inputs and voltage inputs. Direct connection to the FRAKO Energy Management System via integrated interfaces RS85 (Modbus RTU) or Ethernet (Modbus TCP/IP). Description Measuring functions: Frequency of fundamental 0 Hz... 70 Hz Measuring intervals from 10/12 (50/60 Hz) periods (200 ms) Continuous scanning with 20kHz per channel and calculation of the following measurement readings: Voltage L-N, neutral point displacement voltage Voltage imbalance L1... L3 Voltage L-L Frequency (equally for all channels) Current, total current L1... L3, total current L1... L3+N Power (active, reactive, apparent power, power factor, distortion reactive power) Fundamental power (active, reactive, apparent power, cos phi, phase shift) Summation L1... L3 of the above mentioned performance values Summation L1... L (active, reactive, apparent power) Active power (regenerated and consumed) Reactive power (capacitive and inductive) Fourier analyses 1st... 0th harmonic component (harmonics) for current, voltage, active and reactive power Distortion factors (THD) von current and voltage Allocation of the measurement readings to generate protocols for voltage and costs Detection and recording: Detection and recording of the minimum, maximum and average value of the measurement readings defined by the user as well as the acquisition periods for histograms of the parameterized time periods Detection of under- and overvoltages U rms Detection of voltage failures U rms Detection of inrush currents (10 ms) Detection of transients >50 microsec. Energy meter (active and reactive power, regenerated and consumed) with 8 tariffs Internal data storage: 256 MB Flash memory Device equipment: Active matrix display (TFT B x H: 115 x 88 mm), resolution (Pixel): 320 x 20, brightness (cd/m 2 ): 300, screen diagonal 5.7 inch Embedded Webserver Subject to technical changes / FRAKO GmbH / www.frako.com Main Catalogue 2016 - PQ 227

Technical Data Inputs: Voltage measurement inputs Current measurement inputs../1/5a 8 digital inputs: e. g. to change the tariffs, for external synchronisation and to release the records, pulse meter for external consumption meters Outputs: 5 digital outputs, can also be programmed as a pulse or signal output Interfaces / Protocols: RS-85, Protocol: Modbus RTU/Master and Slave for connecting with the FRAKO Energy Management System Profibus DP V0 Interface, with gateway function Ethernet 10/100 TBase Modbus RTU Master/Slave for connection to FRAKO Energy Management System, Modbus-Gateway, BACnet / IP or MSTP (optional) All interfaces run simultaneously Protocols: Modbus TCP/IP (Port 502), Modbus over TCP/IP (Port 8000), HTTP, SMTP, SNMP, SNTP, TFTP, FTP, DHCP Built-in homepage for remote maintenance and diagnostics with open structure for application-specific adjustment User programmable e-mail dispatch, e.g. in case of an alarm Supports HTML pages, Java Applets, Flash MX and ActiveX Configuration and visualization software EM-PQ VIS: Readout and visualization of measurement readings Automatic ring buffer download of the devices Storage of data in a Derby database Optional: MS SQL and MySOL database drivers Graphical representation and analysis of online- and offline-measurement readings Freely configurable topology with freely selectable register levels Configuration of the measurement devices Parameterisation, visualization, data management, analysis Cost centre management Reporting funktion (Voltage and cost centres) for freely definable time periods Statistics function Data export into a CSV file Possibility of customer specified programming (SPS-functionality) The following operating systems are supported: - Microsoft Windows XP (Service Pack 3 or higher) - Microsoft Windows Vista (Service Pack 1 or higher) - Microsoft Windows 7, - MAC OS (10.5 or higher), - Linux and Unix Programming: Integrated interpreter to create customized user programs, e.g. alarms, cost centre allocation, operating conditions,... Freely accessible internal variables (measurement readings ) via reloadable user programs 7 user programs can run at the same time Overvoltage category 600V CAT III Rated voltage in max. 17/720 V AC, +10 % -wire system Rated voltage in max. 80 V AC, +10 % 3-wire system Frequency of 5-65 Hz auxiliary voltage Power consumption 0.1VA Auxiliary voltage L-N 95...20 V AC; 80...30 V DC Power consumption 15 VA Current.../1A/5A measurement Minimum working 5 ma current Power consumption 0.2 VA Voltage ± 0.1 % Current ± 0.2 Power ± 0.2 % Active power Class 0.2 at.../5a Active power Class 0.5 at.../1a Reactive power Class 2 at.../1/5a Operational ambient -10 C...+55 C temperature Relative humidity 5 up to 95 % Ingress protection Front IP50, Rear IP20 Dimensions 1 x 1 x 81 mm (W x H x D) Including Configuration and visualization software EM-PQ VIS Patch cable 3 m, (EM-PQ - Switch/Hub connection) Patch cable 2 m, cross-over (EM-PQ - PC connection) Fastening clamps Article-No. 29-20109 228 Main Catalogue 2016 - PQ Subject to technical changes / FRAKO GmbH / www.frako.com

Optional Accessories Article-No. Type Description 29-20112 Plug DB-9 WITH Terminal plug DB-9 bush (with screw terminals) termination 29-20113 Plug DB-9 WITHOUT Terminal plug DB-9 bush (with screw terminals) termination 29-2011 EM-PQ-VIS Configuration and visualisation software for Power Quality Monitor for EM-PQ 2100, 2200, 2500 and 3000 Dimensions Dimensional drawing EM-PQ 2500 All dimensions in mm Subject to technical changes / FRAKO GmbH / www.frako.com Main Catalogue 2016 - PQ 229

230 Main Catalogue 2016 - PQ Subject to technical changes / FRAKO GmbH / www.frako.com

EMA 1101 Mains Monitoring Instrument Microprocessor 3-phase measurement and monitoring unit with optional connection to the FRAKO Starkstrombus to detect, analyze and monitor electrical measurement variables in 00 V and 525 V low voltage mains or medium voltage mains (100 V secondary). Description Measuring functions: Frequency of fundamental from 0 Hz... 70 Hz Measuring intervals from 10/12 (50/60 Hz) periods (200 ms) Continuous scanning with 20kHz per channel and calculation of the following measurement readings: Voltage L-N, neutral point displacement voltage Voltage imbalance L1... L3 Voltage L-L Frequency Current, total current L1... L3, total current L1... L3+N Power (active, reactive, apparent power, power factor) Fundamental power (active, reactive, apparent power, cos phi, phase shift) Summation L1... L3 of the above mentioned values Summation L1... L (active, reactive, apparent power) Active power (regenerated and consumed) Reactive power (capacitive and inductive) Fourier analyses 1st... 0th harmonic component of current, voltage, active and reactive power Distortion factor (THD) of current and voltage Allocation of the measurement readings to generate protocols of voltage and costs Measurement via three external current converters Measurement of active demand for incoming and regenerated power Menu-driven in plain text and 6 parameters displayed for direct comparison Alarm on exceeding set limits with potential-free NO contact as well as plain text shown on a flashing backlit display Visualisation of the currents as a bar graph to determine the utilization capacity Menu-driven programming in plain text with operator guidance Backlit display Storage of all meter readings and limit values in the event of a mains failure Illuminated LC display of measured values Subject to technical changes / FRAKO GmbH / www.frako.com Main Catalogue 2016 - PQ 231

Technical Data Power supply Mains voltage 230 VAC +/- 10 % Power consumption Max. 7 VA Fuse protection 2 A external protection required Measurement input Voltage path 3x 250 to 550 V AC (external / external conductor) Power consumption: max. 1.0 VA/external conductor Fuse protection: 2 A external protection required Current path 3x X/ 5 A (transformer current > 6 ma) Power consumption: max. 1.8 VA/ transformer connection Outputs 1 Alarm signalling 250 V AC / max. 3 A (potential-free NO contact contact) Inputs Tariff inputs 2 profiles selectable (e. g. HT/NT) Interfaces (mode can be selected) 1 FRAKO For connection to FRAKO Energy Starkstrombus Management System, according to EN 50170 (P-Net), standardised fieldbus, RS-85 Transfer rate: 76.8 kbit/s RS-232 Interface Can be directly connected with a PC via RS-232 interface Transfer rate: 19 200 Baud Operating elements Membrane keyboard with 5 keys Display elements Lid LCD ( lines each of 20 characters) Connections Plug-in connecting strips (supplied) Mechanical construction Dimensions Front plate dimensions: 1 x 1 mm (DIN 3700) Switch panel aperture: 138 x 138 mm (DIN 3700) Installation depth: 105 mm Ingress protection Housing/Terminals IP5/20 according to VDE 070 / EN60529 Version According to VDE 011 / EN 61010 Contamination level 3, EN 50081, EN 50082 Housing Flame retardant UL9-V0 Installation From front panel with screwdriver Mounting position Optional Weight Approx. 1.3 kg Operating conditions Ambient temperature 0 C up to +50 C Versions Article-No. Type Mains Monitoring Instrument for use in 20-30011 EMA 1101 S 3-phase 00 V and 525 V low-voltage systems 20-30005 EMA 1101 3-phase 00 V and 525 V low-voltage systems; Connection to FRAKO Starkstrombus 20-30008 EMA 1101 105V Medium-voltage systems (100 V secondary); Connection to FRAKO Starkstrombus 20-30007 EMA 1101 DP 3-phase 00 V and 525 V low-voltage systemes, with Profibus-DP interface 20-30009 EMA 1101 DP 105V Medium-voltage systems (100 V secondary), with Profibus-DP interface 232 Main Catalogue 2016 - PQ Subject to technical changes / FRAKO GmbH / www.frako.com

EMA 1101 S EMA 1101 EMA 1101 105V EMA 1101-DP EMA 1101-DP For use in 3-phase 00 V and 525 V low-voltage systems For use in mediumvoltage systems (100 V secondary) Connection to FRAKO Starkstrombus Profibus-DP interface Determination of current in PEN (neutral conductor + PE) Bar chart display of the currents and distortion factors Connection to a PC or modem via RS-232 interface (optional) 105V Optional Accessories Article-No. Type Description 20-10310 EM-RS 232 RS-232 adapter for direct access via PC to the data of EMA 1101 (SW-Version 1.11 or higher), EMR 1100 (SW-Version 1.95 or higher) or EMF 1102 (SW-Version 1.0 or higher) 20-10309 EM-RS 232 for modem operation RS-232 adapter for access to the data of EMA 1101 (SW-Version 1.11 or higher), EMR 1100 (SW-Version 1.95 or higher) or EMF 1102 (SW-Version 1.0 or higher) via modem 20-10311 EMA-SW Software for the configuration and onlinedisplay of the Mains Monitoring Unit EMA 1101. Access via: EMIS 1500, EMP 1100, EMT 1101 and RS-232 adapter. Note: included with FRAKO- NET (when supplied on CD). Subject to technical changes / FRAKO GmbH / www.frako.com Main Catalogue 2016 - PQ 233

Dimensions Dimensional drawing EMA 1101 All dimensions in mm 23 Main Catalogue 2016 - PQ Subject to technical changes / FRAKO GmbH / www.frako.com

EMA 196 Mains Monitoring Instrument The unit measures and displays all major electrical and power quality parameters, including imported real and reactive energy, in terms of Wh, kwh, MWh, VArh, KVArh and MVArh for single phase, three-phase-3-wire or three-phase--wire supplies. In order to measure these parameters, the unit requires voltage and current inputs in addition to the supply required to power the unit. The current input (s) are obtained via current transformers (CTs). The unit can be configured to work with a wide range of CTs, giving the unit a wide range of operation. Option modules can be fitted to provide pulse and RS-85 Modbus/JC N2 outputs. The unit can be powered from a separate auxiliary a.c. (or d.c.). Alternatively it can be powered from the monitored supply, where appropriate. Description Precise display of all major electrical and power quality parameters Measures 17 electrical parameters, including total harmonic distortion (THD) up to the 31st harmonic Energy meter for active and reactive power Plug-in output modules (option): 1 output per module Max. 2 modules possible (type, valency, duration) for active or reactive work (kwh or kvarh) for transmission to FRAKO Cost Centre and Alarm System EMF or PLC Plug-in output module (option) for connection to a FRAKO Energy Management System, Modbus RTU Front panel installation, DIN 96 enclosure Optional Accessories Programmable pulse output (EMA 196 EXT IMP): Type, valency and duration - active or reactive work (kwh or kvarh) can be provided for PLC or FRAKO EMF 1102 Cost Centre and Alarm System Module RS-85 (EMA 196 EXT MODBUS): Connection of EMA 196 to the FRAKO Energy Managment System can be realized via this interface RS-85 using the Modbus RTU or the Johnson Controls Metasys N2 protocol, enabling all measurement readings to be recorded and monitored. Subject to technical changes / FRAKO GmbH / www.frako.com Main Catalogue 2016 - PQ 235

Technical Data Power supply AC voltage 110 up to 00 V AC (max. 99 up to 0 V AC) DC voltage 120 up to 350 V DC (max. 96 up to 20 V DC) Frequency 5-66 Hz Power Max. 5 VA consumption Measuring input Connection type / /-, 2-wire and single-phase 3//5-wire Current 3 x X/5A measurement input Voltage 3 x 100-289 V AC (phase/neutral conductor) measurement 3 x 173-500 V AC (phase/phase conductor) input In-/Outputs Analogue In-/ - / - Outputs Digital In-/Outputs - / optional plug-in for active and reactive energy Interfaces FRAKO Energy Optional plug-in module offers connectivity Management via Modbus RTU System Measurement accuracy Current 0.5 % Voltage 0.5 % ( %: I2 in 3-phase 3-wire operation) Calculated neutral % current Power factor 1 % of equality Frequency 0.1 Hz Active power ± 1 % of range maximum Reactive power ± 1 % of range maximum Apparent power ± 1 % of range maximum Active energy Class 1 (IEC 62053-21) Reactive energy ± 1 % of range maximum THD 1 % up to 31 st harmonic Response time to 1 s, typical to 99 % of the final value step input Repetition rate recording Max. 300 ms (maximum for %THD registration) Operating keys elements Display elements Backlit LCD Connections Covered box terminals: 0.05-2.5 mm 2 Mechanical construction Dimensions 96 x 96 x 6.1 (W x H x D), installation depth: 58 mm (with modules: 82.5 mm) Ingress protection Front: IP52 (IP5 using an additional seal) Housing: IP30 Version IEC 61326/61010-1/62053-21 Housing Flammability to UL 9-V0 Installation Front panel installation Weight 300 g Operating conditions Operating 10 C up to +55 C temperature Article-No. 29-201 236 Main Catalogue 2016 - PQ Subject to technical changes / FRAKO GmbH / www.frako.com

Optional Accessories Article-No. Type Description 29-2015 EMA 196 EXT IMP 29-2016 EMA 196 EXT MODBUS Configurable pulse module for Mains Monitoring Instrument EMA 196 for passing the pulses of active and reactive power (kwh or kvarh) to a PLC or the Cost Centre and Alarm Unit EMF 1102. Type, valency and duration of the pulse output can be configured. Communication module for Mains Monitoring Instrument EMA 196 for connection to the FRAKO Energy Management System via RS-85 with JBUS-/Modbus-Protocol, enabling all measurement recordings to be recorded, monitored and analyzed by PC using the visualization software EMVIS 3000. For connection to EMIS 1500 Central Unit a Modbus coupler (Art.-Nr. 20-10220) is required. Dimensions Dimensional drawing EMA 196 All dimensions in mm Subject to technical changes / FRAKO GmbH / www.frako.com Main Catalogue 2016 - PQ 237

238 Main Catalogue 2016 - PQ Subject to technical changes / FRAKO GmbH / www.frako.com