ECONOMIZERS. Z1ECON30B-1 ECONOMIZER (Cat No. 10Z29) INSTALLATION INSTRUCTIONS FOR ECONOMIZERS USED WITH ZC,ZG,ZH UNITS CAUTION WARNING

Similar documents
Downflow Economizers Z1ECON30 (98W09) ECONOMIZERS

IN STAL LA TION IN STRUC TION

Installation Instructions

Installation Instructions

Economizer Controller Installation Guide

INSTALLATION INSTRUCTIONS ECONOMIZER WITH EXHAUST

INSTALLER'S GUIDE ECON-IN-30B 18-HE60D83-3. Accessory Economizer Downflow

INSTALLATION INSTRUCTIONS MBPEFY Series Mixing Box for Mitsubishi PEFY Series Units. Before Starting Installation Warning. Installation Instructions

MODELS DSH/DSV R-410A AIR SIDE ECONOMIZER KIT

MODELS DSH/DSV R-410A AIR SIDE ECONOMIZER KIT

Field Installation Manual External Bolt-On Economizer for ComPac I Air Conditioners

SE7600E Series Application Guide

INSTALLATION INSTRUCTIONS ECONOMIZERS WITH EXHAUST. For Use with Bard 3-1/2 through 6 Ton Wall Mount Air Conditioners and Heat Pumps

INSTALLATION INSTRUCTIONS MODELS (-)XRD-01RJDCM3 & (-)XRD-01RJDDM3 VERTICAL AIRFLOW ECONOMIZERS

INSTALLATION INSTRUCTIONS MODELS (-)XRD-01RJHCM3 HORIZONTAL AIRFLOW ECONOMIZERS

INSTALLATION INSTRUCTIONS MODELS RXRD-RJCM3 HORIZONTAL AIRFLOW ECONOMIZERS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS MODELS (-)XRD-UKCM3 & (-)XRD-TKCM3 CONVERTIBLE AIRFLOW ECONOMIZERS

Fast Route to Reliable Energy Savings ZIP Economizer

INSTALLATION INSTRUCTIONS MODELS (-)XRD-PJCM3 & (-)XRD-SJCM3 VERTICAL AIRFLOW ECONOMIZERS

INSTALLATION INSTRUCTIONS ECOHPRS Series Horizontal Economizer for York PRESTIGE for ZX 04-07; ZY 04-06

INSTALLATION INSTRUCTIONS MODELS (-)XRD-01RMDCM3 & (-)XRD-01RMDDM3 VERTICAL AIRFLOW ECONOMIZERS

JADE Economizer Module (MODEL W7220)

ECON-ZIP-BASE. ZIP Economizer Base Unit. Wiring Diagram USA CANADA LATIN AMERICA / CARIBBEAN

HVAC unit. Spacerfor. ILL. 3 1" filter. Screw

READ COMPLETELY BEFORE INSTALLING!!!

Warning. Important. Always follow all local building electrical codes. PECCSUN3672DB46M PECCSUN3672EN46M

THERMOSTATS & CONTROLLERS

Economizer Control 2-1

SE7600E Series Application Guide

INSTALLATION MANUAL FOR CARRIER/BRYANT 3-15 TON ECONOMIZERS 3-6 TON MODELS

DUKE UNIVERSITY DESIGN & CONSTRUCTION STANDARDS

Installation and Operation Instructions I/CO 2, I/CO 2 -VDC, I/CO 2 -T

INSTALLATION INSTRUCTIONS ECODPRD3715 Series Vertical Economizer for York Predator 3-12½ Ton Units

Installation, Start-up and Operating Instructions

Millennium Simplicity Elite Parameter Points and Quirks

INSTALLATION INSTRUCTIONS ECOHAFF1860 Series Horizontal Economizer for York Affinity 3-5 Ton Units. Before Starting Installation Warning

ETM-2050/ETM-2051 Service Manual

CDR-RH Room CO 2, Temperature and Humidity Sensors (Controllers)

PROLON INSTALLATION AND START UP GUIDE

INSTALLATION INSTRUCTIONS

BA/BS4S Temperature Sensor Installation & Operating Instructions

POL220 Series Economizer Controller

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION!

INSTALLATION INSTRUCTIONS ECONOMIZER WITH EXHAUST

FOR SERVICE TECHNICIAN S USE ONLY

T7560A1036 Digital Wall Module

TOXALERT MODEL AIR 2000

Custom Controller Installation Instructions

SUPPLEMENTAL MANUAL FACTORY-INSTALLED LENZE AC TECH VARIABLE FREQUENCY DRIVES (VFD) IN RENEWAIRE (ERV) VENTILATORS TABLE OF CONTENTS

NT50 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat

Table I - Package Contents. Table 2 - Filter Sizes. Read these instructions completely before attempting to install the Vertical Economizer Accessory

Daikin McQuay. Incremental Comfort System. PKEI, PKES, PKHS 007, 009, 012, 014 Design 2. Replacement Parts List No Revision G 12/2013

AirTest Model CN9000 Series Sensor Controller

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

ECON-ZIP-BASE. ZIP Economizer Base Module

CDD4 Duct Carbon Dioxide Transmitter

M1000 INTELLIGENT ZONE CONTROL SYSTEM

ASI Systems ML5720A Series

CTR21, CTR22, CTR23, and CTR24 Wall Modules

C7110C1001A / C7110D1009A WALL MODULES

FCU (FREE COOLING UNIT)

CONTROLLER INSTALLATION OPERATION & QUICK START

VAV system solution for non-pressure dependent applications in enclosed spaces

VAV Modular Assembly (VMA) 1410/1420

Tracer Controls. Tracer MP501 Controller BAS-PRC008-EN. January 2005

RTULink Monitoring and Control Installation, Operation, and Maintenance Manual

INSTALLATION, OPERATION & MAINTENANCE MANUAL INTEGRATED PROGRAMMABLE CONTROLS

Installation Instructions

FOR SERVICE TECHNICIAN S USE ONLY

Packaged Rooftop Air Conditioning Units

USER'S GUIDE BARD-LINK TM LC /LC SOLID STATE DUAL UNIT LEAD/LAG CONTROLLER & TEC-EYE HAND-HELD DIAGNOSTIC TOOL

*740130* 2800, 9500 Series. Cable Companion Motor Power. Cable AC Power. Cable Retrofit Acessories

Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit

HLS34 Modbus FCU/VAV Controllers installation instructions

Measure & Control Temperature & CO2 levels with analog & digital I/O

Instruction Manual CTC-1

MX1 Reversible AC Motor Controller. Supplementary Wiring Examples

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

Installation and Operation Instructions

Installation and Operation. Tracer MP501 Controller CNT-SVX08B-EN

H7625B; H7635B,C; H7655B Duct-Mount and Outdoor-Mount Humidity/Temperature Sensors

Tracer Controls. Tracer ZN517 Unitary Controller BAS-PRC012-EN

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

INSTRUCTION MANUAL RA 59 RACK ADAPTER. 1) This manual is valid for the following Model and associated serial numbers: MODEL SERIAL NO. REV. NO.

ASI Systems ML5740A Series

BACnet MS/TP Interface User s Guide

CDD4 Series Room CO2 Transmitter Installation Instructions

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

Installation Instructions

DLA. DMX512 Analyzer. DLA Users Manual SV2_00 B.lwp copyright ELM Video Technology, Inc.

McQuay. Commercial Unitary Rooftop Cooling Only or with Electric Heat. LCA Design 1. Last Manufactured: 2004

Zone Manager INSTALLATION MANUAL 40KMC KMQ QNC QNQ

MicroTech 2000 Water Source Heat Pump Unit Controller

Tracer Controls. Tracer MP.501 Controller BAS-PRC008-EN. June 2001

T7560A,B,C Digital Wall Module

SEZ7656E1045B. Installation Guide for BACnet MS/TP RTU Terminal with IAQ Control CONTENTS

AC300/AC400 SERIES DYNAMIC BRAKING and ADDITIONAL FORM C RELAY. INSTALLATION INSTRUCTIONS Document Number:

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

INSTALLATION & OPERATING INSTRUCTIONS. ECONOMIZERS WITH EXHAUST for EQUIPMENT BUILDING APPLICATIONS

Transcription:

Litho U.S.A. 2014 ECONOMIZERS 3/2014 Supersedes: New Z1ECON30B-1 ECONOMIZER (Cat No. 10Z29) INSTALLATION INSTRUCTIONS FOR ECONOMIZERS USED WITH ZC,ZG,ZH 092-150 UNITS Application The Z1ECON30B-1 economizer is used with ZC,ZG,ZH 092-150 units in downflow air discharge applications. Economizer dampers will modulate to maintain 55 o F (13 o C) supply air when outdoor air is suitable. The mixed air temperature sensor measures the supply air sensible temperature. An outdoor air sensor is used to determine whether outdoor air is suitable for free cooling. The outdoor air sensor is factoryinstalled in all economizers. Other outdoor and return air (OA and RA) sensor options are available to determine whether outdoor air is suitable for free cooling. See Table 1 and the instructions provided with optional senors.! Figure 1 Shipping and Packing List Package 1 of 1 contains: 1 - Economizer damper assembly 1 - Outdoor air damper 1 - Return air damper 1 - Gravity exhaust damper 1 - Economizer actuator 1 - Economizer control module 1 - Outdoor air temperature sensor 1 - Top seal panel 1 - Lower panel (hood top) 1 - Mixed air sensor 1 - Hardware bag 1 - Hood parts package 1 - Left hood side 1 - Right hood side 1 - Hood divider 1 - Hood filter 1 - Wiring Diagram Label Order Of Installation Economizer Mixed air sensor Optional OA and RA sensors Optional Power Exhaust Fans WARNING Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss of life. Installation and service must be performed by a qualified installer, service agency or the gas supplier Sensors *Single OA Sensible Single OA Enthalpy Differential Enthalpy - 1 in OA & 1 in RA INDOOR AIR QUALITY SENSOR (A63) An IAQ sensor is used when demand control ventilation (DCV) is specified. Damper minimum position can be set lower than traditional minimum air requirements resulting in cost savings. The IAQ sensor allows the economizer control module to open dampers to traditional ventilation requirements as room occupancy (CO 2 ) increases. For proper operation, the IAQ sensor must provide a 2-10VDC, 100 ohm impedance signal. Connect sensor leads to AQ and AQ1 terminals on the economizer control module located in the filter section.! TABLE 1 Dampers modulate to maintain 55 o F mixed air (R1) when: OA temperature (S175) is lower than free cooling setpoint OA temperature and humidity (A7) is suitable for free cooling OA temperature and humidity (A7) is lower than RA temperature and humidity (A62). *Single OA sensible sensor is shipped standard on economizer CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges. 1

Install Economizer 1. Disconnect all power sources to the unit 2. Remove the following panels from the unit; - Filter door panel - Return chamber panel - Blower access panel - Control panel When filter door and return chamber are removed there will be a cross support still in the unit streatching from side to side of the return chamber Filter door Blower access panel (backside) 3. Remove hood parts package. 4. Install damper assembly into unit under the cross support. Fit opening in bottom of damper assembly over the return air opening. See Figure 3. 5. The upper panel of the economizer will screw into the cross support through pre-punched holes. 6. Secure the economizer to unit base pan with five screws. Economizer J10, P10 Plug Return chamber panel Figure 3 - Economizer Installtion Figure 2 Grommet for high voltage power exhaust wires See note 5 above 9 pin economizer/ mixed air sensor plug (J142) Top seal panel Filter door Outside air damper Outside air temperature sensor Plug for optional power exhaust Gravity exhaust damper Figure 4 2

PNK GRY WHT Economizer Wiring 1. The economizer control module is located below the actuator for shipping. Relocate the control to the unit control box, see Figure 5A. 2. Route the control wires to unit terminal block (TB1) and connect these wires to TB1 as following (see Figure 5A): Connect all female terminals to TB1 - Pink (24V) to R; Grey (GND) to ground; Yel (Cool 1) to Y1; and Blue (Cool 2) to Y2. Disconnect the factory installed terminals at TB1, Y1 and Y2. Connect these terminals to control male terminal Y1 and Y2 3. Attach the control harness jack (J142) to prewired harness plug (P142). 4. At economizer/filter compartment, attach economizer plug (P10) to prewired harness jack (J10). See Figure 3. 5. Connect any optional sensors as shown in Figure 5. 6. If optional power exhaust is used, wire according to instructions provided with power exhaust. See Figure 5. 7. Apply wiring diagram to the control panel. See Figure 5B. Install Mixed Air Sensor 1. Remove the mixed air sensor from the economizer parts bag. The sensor has a small ring terminal. See Fig. 6. 2. Locate the 2 mixed air sensors wires in the unit from plug J3. The mixed air sensor wire color is white. Attach these 2 wires to the mixed air sensor wires. 3. Mount the mixed air sensor to the indoor fan through the existing screw on the blower. See Fig. 6A. 4. Secure wires in place so they don t interfere with unit operation. 5. Replace all panels. WIRE CONNECTIONS OUTDOOR AIR TEMPERATURE SENSOR PROVIDED (ENTHALPY OPTIONAL) TO ECONOMIZER Mixed Air Sensor Provided (R1) P10 J10 J18 POWER EXH PLUG 5-PIN P142 J142 GRY YEL BLK BLU RED DAMPER MOTOR *PLUG J24 ECONOMIZER CONTROL MODULE EF1 EF SO SO+ SR SR+ T1 T AQ AQ1 BLU VIO 7 8 DIFFERENTIAL ENTHALPY SENSOR (OPTION) RED BLK GRY PNK Actuator plug J9 P9 IAQ SENSOR (OPTION) *3 Pin High Voltage Power Exhaust Plug Figure 5 - Wiring Detail 3

Economizer (J142, P142) Economizer Control Module Figure 5A - HVAC Control Box Apply wiring diagram here Mixed Air Sensor Figure 6A - Mixed Air Sensor Location Hood top (lower panel) 48 3/16 25 5/16 Right hood side Figure 5B 24 Left hood side Hood divider Figure 7 Hood filter Figure 6 - Mixed Air Sensor 4

Outdoor Air Hood If using a power exhaust accessory skip this step. The hood parts shipped with the economizer will not be used. 1. Remove the hood top from the economizer assembly. 2. Install the hood sides to the hood top, see Figure 7. 3. Screw the hood divider to the hood sides. Divider sits between the left and right hood side. Bottom angle of divider is used for the filter rack. 4. Open the filter clips on the underneath side of the hood top and insert filter. See Figure 8. 5. With hood assembled, fit the mating flange on hood top underneath the knuckle on the top seal panel. Install the hood over economizer as shown in Figure 3, 4 and 9. 6. Screw hood to unit as shown in figure 9. Hood top Economizer Control Module TABLE 2 ECONOMIZER CONTROL MODULE LEDs LED Free Cool Demand Control Ventilation (DCV) When Lighted Indicates Outdoor air is suitable for free cooling Indoor IAQ is above set point requirement more fresh air Economizer A6 ENTHALPY Control CONTROL Module 2V EXH EXH Set 10V DAMPER MINIMUM POSITION Filter clip Hood filter 2V Open Min Pos DCV Max 10V IAQ MAXIMUM POSITION (set higher than minimum position) Figure 8 DCV DCV LED Unit filter access door 2V Free Cool DCV Set 10V IAQ SETPOINT B C FREE COOL LED A D FREE COOLING SETPOINT; A=Completely counterclockwise D=Completely clockwise Figure 10 Economizer hood Upper Panel Figure 9 5

FREE COOLING CHANGEOVER Note - The following conditions assume unit is operating during occupied period. Single Outdoor Air Temperature Sensing: The temperature sensor shipped with the economizer is used to determine outdoor air suitability for free-cooling. The sensor has a fixed changeover and cannot be adjusted. Set the A,B,C,D setting on economizer control module to the D setting. The sensor will allow economizer to go to free-cooling mode when the temperature falls below 55 o F, and will then disable freecooling when temperatures rise above 70 o F. Single Enthalpy Sensing: Note - The following conditions assume unit is operating during occupied period. Single Outdoor Air Enthalpy Sensing: The enthalpy sensor is an optional accessory. The temperature sensor shipped with the economizer will be removed and discarded, and the enthalpy sensor field installed. The enthalpy sensor is used to determine outdoor air suitablility for freecooling, see Table 3. Free cooling will be enabled when the outdoor air enthalpy is lower than the free cooling setpoint. Table 3 shows the free cooling setpoints which are adjustable on the economizer control module. For example: At setting A (Table 3), free cooling will be enabled when outdoor air enthalpy is lower than 73 o F and 50% RH. If indoor air is too warm or humid, lower the setpoint to B. At setting B, free cooling will be enabled at 70 o F and 50% RH. Differential Enthalpy Sensing: Outdoor air and differential enthalpy sensors are optional accessories. Two enthalpy sensors can be used to compare outdoor air to return air. When outdoor air is cooler than return air and free cooling setpoint, outdoor air is suitable for free cooling. Adjust the free cooling setpoint to D in this application. Table 3 shows the free cooling setpoints for enthalpy sensors. For example: At setting D (Table 3), free cooling will be enable when outdoor air enthalpy is lower than return air enthalpy AND free cooling setpoint 63 F / 50% RH. If indoor air is too cool or dry, increase the setpoint to C. When return air is cooler than outdoor air, the damper will modulated to the minimum position Table 3 6

DAMPER MINIMUM POSITION SETTING NOTE - 24 volts must be provided at unit 24 volt leads R and OC to enable economizer operation (allowing minimum fresh air). Typically a separately ordered thermostat or energy management system with an occupied/unoccupied output is connected between R and OC leads. The thermostat will provide 24 volts to the economizer control during the occupied time period to enable the economizer. If a device is not used to enable the economizer, install a jumper between R and OC leads R and OC to maintain minimum position continuously. Make wire connections to leads R and OC as shown in literature provided with thermostat or energy management system. 1. Set thermostat to occupied mode if the feature is available. Make sure jumper is in place between leads R and OC if using a thermostat which does not have the feature. 2. Rotate MIN POS SET potentiometer to approximate desired fresh air percentage. Use care when adjusting minimum potentiometer to avoid damaging potentiometer. Note - Damper minimum position can be set lower than traditional minimum air requirements when an IAQ sensor is specified. 3. Measure outdoor air temperature. Mark the point on the bottom line of chart 1 and label the point A (40 o F, 4 o C shown). 4. Measure return air temperature. Mark that point on the top line of chart 1 and label the point B (74 o F, 23 o C shown). 5. Measure mixed air (outdoor and return air) temperature. Mark that point on the top line of chart 1 and label point C (70 o F, 21 o C shown). 6. Draw a straight line between point A and B. 7. Draw a vertical line through point C. 8. Draw a horizontal line where the two lines meet. Read the percent of fresh air intake on the side. 9. If fresh air percentage is less than desired, adjust MIN POS SET potentiometer clockwise (further open). If fresh air percentage is more than desired, adjust MIN POS SET potentiometer counterclockwise (less open). Repeat steps 3 through 8 until calculation reads desired fresh air percentage. F C 20 29 0 10 20 30 40 50 60 70 80 CHART 1 CALCULATE MINIMUM FRESH AIR PERCENTAGE MIXED AND RETURN AIR TEMPERATURE 0 10 20 30 40 50 60 70 80 90 18 12 7 1 4 10 16 21 27 32 C B 10 23 100 38 F C 0 10 20 30 40 50 60 70 80 90 100 F 20 C 29 10 23 0 18 A 10 12 20 7 30 1 40 4 50 10 60 16 70 21 OUTDOOR AIR TEMPERATURE 80 27 90 32 100 38 90 100 F C 7

DCV SET AND DCV MAX SETTING The DCV SET potentiometer is factory-set at approximately 50% of the potentiometer range. Using a standard 1-2000ppm CO 2 sensor, dampers will start to open when the IAQ sensor reads approximately 1000ppm. Adjust the DCV SET potentiometer to the approximate setting specified by the controls contractor. Refer to figure 10. The DCV MAX potentiometer is factory-set at approximately 50% of the potentiometer range or 6VDC. Dampers will open approximately half way when CO 2 rises above setpoint. Adjust the DCV MAX potentiometer to the approximate setting specified by the control contractor. Refer to figure 10. Note - DCV Max must be set higher than economizer minimum position setting for proper demand control ventilation. Economizer Operation When the outdoor air is suitable, dampers will modulate between minimum position and full open to maintain 55 o F (12 o C) supply air. See Table 4 for economizer operation when outdoor air is suitable. See Table 5 for economizer operation when outdoor air is NOT suitable. IAQ Sensor During the occupied period, dampers will open to DCV MAX when IAQ reading is above setpoint (regardless of thermostat demand or outdoor air suitability). DCV MAX will NOT override damper full-open position. The DCV MAX setting may override damper free cooling position when occupancy is high and outdoor air temperatures are low. Note - If mixed air sensor senses mixed air temperature below 45 o F (7 o C), dampers will move to minimum position until mixed air temperature rises to 48 o F (9 o C) THERMOSTAT DEMAND TABLE 4 ECONOMIZER OPERATION OUTDOOR AIR IS SUITABLE FOR FREE COOLING -- FREE COOL LED DAMPER UNOCCUPIED OCCUPIED 1 MECHANICAL COOLING OF Closed Closed No F Closed Minimum No Y1 Modulating* Modulating* No Y2 Modulating* Modulating* STAGE 1 *IAQ sensor can open damper to DCV max. 1 Damper position when no occupied/unoccupied signal is available from building thermostat or energy management system. THERMOSTAT DEMAND TABLE 5 ECONOMIZER OPERATION OUTDOOR AIR IS NOT SUITABLE FOR FREE COOLING -- FREE COOL LED DAMPER UNOCCUPIED OCCUPIED 1 MECHANICAL COOLING OF Closed Closed No F Closed Minimum* No Y1 Closed Minimum* STAGE 1 Y2 Closed Minimum* STAGE 1 *IAQ sensor can open damper to DCV max. 1 Damper position when no occupied/unoccupied signal is available from building thermostat or energy management system. Form No. 1-1P 8