GS-X v.iii Guarding Safety Controller Hold-to-Run Switch

Similar documents
To identify if a CPU PCB upgrade will be needed, refer to the following steps. Figure 1 - Modified CPU with Heat Sink

Upgrading LVDS Cables Instruction Sheet

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS

GS-Series Pinsetters and Associated Brunswick Bowling Equipment

Field Installation Manual External Bolt-On Economizer for ComPac I Air Conditioners

XDBKITS5 Bus / DB Terminal Kit (Size 5) Installation Manual DPD00116

GS-Series Pinsetters and Associated Brunswick Bowling Equipment

Presentation. EUCHNER Multifunctional Gate Box MGB

Samsung Galaxy S5 Active Motherboard

Procedure to Install an IO Expansion Cage Assembly in a Maxum II Modular Oven Analyzer

Removal and Installation8

E1135C PDU and Pod Upgrade Procedure

Model: ACA400 & ACA500 Reverse Camera Installation Manual

Fuser. Figure Remove the fuser assembly (1 of 2) 184 Chapter 5 Removal and replacement ENWW

Instruction Bulletin Trim and Rail Extension Kit (6-, 12-, and 18-inch) Installation onto an NF Panelboard Class 1670

IBM. Rack Installation Instructions

Chapter 4 Replacement Procedures

Three-position. device during trouble shooting, the safest solution. programming and testing. Three-position devices in different versions.

Mac mini Mid 2010 IR Sensor Replacement

imac Intel 27" EMC 2639 Hard Drive

Canon Powershot S200 Camera lens Replacement

Written By: Joel groff

Single Kernel Grain Moisture Tester PQ-520. (type PQ ) Operating Instructions

Making Hazardous Operations Safe and Productive

Agilent N2916B 6000 and 5000 Series Oscilloscope Rack Mount Kit

How-To: Disassembly Instructions UD3

Opening a PIX Firewall Chassis

Ethernet Adapter Installation Instructions

System Storage EXP3000 Rack Installation Instructions

Model 2657A-LIM-3 LO Interconnect Module

Assembling the Christie QwikRig rigging frame

4.1 General. 4 Replacement Procedures

Laser Alignment. For the Epilog Fusion CO2 10/10/2013

CBT LW 4-PUMP ADD-ON INTERNATIONAL INSTALLATION GUIDE

GS-Series Pinsetters and Associated Brunswick Bowling Equipment

PACSystems* RX3i IC695ACC650

WARNING ELECTRICAL SHOCK HAZARD

E3FS. Connect up to 4 sets of E3ZS/E3FS per B1 Module for F3SX Safety Controller

Samsung Galaxy Tab Speaker

Written By: Andrew Optimus Goldberg

LSM-HD-BE 9 - Lift System Medium with Box Enclosure

Bear Power Supplies Engineering Department Smart Power Supply Test Bench

Roof Truss Roller Press, Tables and Jigging

Canon Powershot SD550 Zoom Lens Assembly Replacement

Product Discontinuation Notices. Discontinuation Notice of Safety Laser Scanner Type OS3101 series

Networking sensors. Distributing safety. Reducing automation cost. Product Overview AS-Interface

ABM International, Inc. Lightning Stitch Checklist 9/13/2013

Instruction Sheet WPC 2000 Option 1

IBM Systems. Quick start guide for IBM System p5 505 ( )

Subject: 24 Volt Hand Dryer Replacement Option Conversion Kit Package v Hand Dryer to 115v / 230v Hand Dryer

SKIVING MACHINE MAINTENANCE & INSTRUCTIONS MANUAL ASSK2. Allswage UK. Roebuck Street, West Bromwich, B70 6RB

Power Xpert Meter 2000 Gateway Card Kit

MacBook Pro 17" Models A1151 A1212 A1229 and A1261 Display Inverter Replacement

Alcatel One Touch Pop 7 Display Assembly Replacement

HP 15-r137wm TouchSmart Screen

imac Intel 27" Retina 5K Display CPU Replacement

Canon PowerShot SX530 HS Shutter Release Cover Replacement

Rack Installation Instructions

HD22 and HD30 Service Parts

INSTALLING THE WINDOWS-BASED DRIVER NOTICE!

F3SJ-A F3SJ-A. Safety Light Curtain. safety light curtain that. Options. software. The F3SJ-A system is a fullfeatured

logic table of contents: squarebot logic subsystem 7.1 parts & assembly concepts to understand 7 subsystems interfaces 7 logic subsystem inventory 7

ALL-FLEX ELECTRIC TABLE BASE

Mac Mini Mid 2010 SSD Installation

Automatic Access Interlock User Manual - Original Language Version

Remote Control Electrical Roller Blinds

Kinetix 6000 Axis Module and Shunt Module

TOYOTA YARIS HATCHBACK Preparation

Controller PC Hard Drive

OLPC XO-4 Touch Mouse Buttons Controller Replacement

Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216

DIGITAL OBSERVATION GUARD LOW PROFILE PAN TILT KIT USER MANUAL

HP TouchPad USB Connector Board Replacement

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

BL-FLOWSTN-P FlowStation Module Installation Guide

LSM TU HF 6 - Lift System Telescopic - Electric Heavy Flap

SAFETY LOCKING DEVICES

ipad mini 4 LTE Screen and Digitizer Replacement

Labeling accessories Art.-No. suitable. Wiring accessories Art.-No. suitable. Color: blue 10-pole spacing 6.2 mm MIRO 6.2

Vapor Monitor Interface Module

Emergency Stop Pushbutton Switches ( 22 and 30) Integrating Synchro Safe Contact

Operators Guide. Vision 8 Pan & Tilt Head. Vinten Camera Control Solutions

Setup Guide. Confirming the Installation Space. Installation space (W x D x H) 70.5 x 66.3 x 61.5 inches (1790 x 1684 x 1560 mm) 23.

POE. The majority of PSE equipment requires a detection resistance of 24.9KΩ to establish a PoE link. Some models of PSE equipment require12.5kω.

VI - Safety techniques

Assembly and Operating Instructions. M2 module for BDC-i440 control units

Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24

Three position. device shooting, programming and testing. the safest solution during trouble. Three-position devices in different versions.

TT-2000&D2000 Ticket Eater with AP-100 Logic Board

TrendView recorders - Installation Instruction

Emergency stops and Pilot devices

Samsung Galaxy S5 Active Front-Facing Camera Replacement

Rack Installation Instructions

ihome ih9 Infrared Receiver Replacement

SITRANS F. Flowmeters SysCom Upgrade Kit IP65 (NEMA 4X) Multi-Channel. Introduction 1. Installing/Mounting 2. Hardware Installation Instructions

Nikon D610 Flash Capacitor Replacement

Online data sheet. S30A-7021EK S3000 Anti Collision SAFETY LASER SCANNERS

Samsung Galaxy Tab Motherboard

PS/IO Circuit Board Retrofit

MBE Mounts and Adapters

Transcription:

GS-X v.iii Guarding Safety Controller Hold-to-Run Switch Packaging 1 ea. 47-142117-000 Pkg. Hold-to-Run Cable Assembly *1 ea. 47-142118-000 Pkg. Hold-to-Run Switch 1 ea. 47-902601-000 Installation Instructions * One per Center Item Tools Required - Straight (flat) Screw Driver - Phillips (cross) Screw Driver Hold-to-Run Cable Assembly 47-142117-000 The Hold-to-Run cable assembly provides a connection on the Safety Controller for the Hold-to-Run switch. A cable must be wired into each safety controller where a Hold-to-Run operation is desired. Refer to Figure 1. Figure 1 Brunswick Bowling & Billiards Corp. 2012. All rights reserved. September 2012 1 47-902601-000

Hold-to-Run Cable Installation in the Safety Controller WARNING! Turn off the main power to the pinsetter at the main electrical panel and turn OFF the main power switch on the safety controller. 1. Remove and discard cover plate from safety controller and retain all screws for re-use. Refer to Figure 2. IMPORTANT!: Save all screws. Figure 2 2. Remove the cover from the safety controller. WARNING! Verify all lights inside the safety controller are off before continuing. 2

3. Install hold-to-run cable assembly into safety controller with the 4 screws from step 1. Refer to Figure 3. Figure 3 3

4. Wire the hold-to-run cable assembly to safety controller. Refer to Figure 4 and Schematic of Hold-to-Run Cable Figure 1. Figure 4 5. Secure the cover removed in step 4 to the safety controller. 4

Hold-to-Run Switch 47-142118-000 The Hold-to-Run switch is a manually operated switch that allows work to be conducted in the GS-X pinsetter areas while the machine is operating. Refer to Figures 5 & 6. Figure 5 Figure 6 NOTE: When the Hold-to-Run switch is not in use, remove it from the safety controller and store in a secure location. 5

The Hold-to-Run switch has three positions that provide three operating modes. Refer to Figure 7. Figure 7 6

Functional Test of the Hold-to-Run Switch WARNING! The effectiveness of the Hold-to-Run switch must be tested before use. Occupy a safe area, outside of the GS-X pinsetter and away from any dangerous parts or areas that could cause injury. 1. With the hold-to-run switch connected to the safety controller (refer to page 4, Figure 6) in position 1 state (off, push button not pressed, GS-X pinsetter not operating), check all the protective devices, interlocks and sensors before any work or the dangerous state of the pinsetter is initiated. a. Completely cover each light beam with a test piece that is not transparent (at least 30 mm [1-3/16 ] diameter) at the following positions: - Directly in front of the sender - In the middle between sender and receiver - Directly in front of the receiver b. Open the rear pinsetter access door with the interlock switch. c. Open the masking unit interlock switch. d. Press the emergency stop button. Each of the preceding individual tests must produce the following result: - During the light beam test the receiver for the related safety photoelectric safety switch must have no LED illuminated. - As long as the light beam, interlock or emergency stop switch is interrupted, it must not be possible to initiate the dangerous state of the pinsetter. 2. Operate the hold-to-run switch and verify all three positions (refer to page 5, Figure 7) operate correctly while the GS-X pinsetter is in the dangerous state: Position 1 - Off, push button not pressed, GS-X pinsetter not operating Position 2 - Enabled, push button pressed to center position, GS-X pinsetter operational Position 3 - Disabled, push button pressed to full down position, GS-X pinsetter not operating 3. Operate the hold-to-run switch in the position 2 state (enabled, push button pressed to center position) and verify all the interlocks and sensors will NOT disable the dangerous state of the pinsetter: a. Completely cover each light beam with a test piece that is not transparent (at least 30 mm [1-3/16 ] diameter) at the following positions: - Directly in front of the sender - In the middle between sender and receiver - Directly in front of the receiver b. Open the rear pinsetter access door with the interlock switch. c. Open the masking unit interlock switch. d. Press the emergency stop button. During each of these tests the pinsetter should stay operational in the dangerous state WHILE the hold-torun switch is in the position 2 state (enabled, push button pressed to center position). 7