Dual Duct Controller - One Air Velocity

Similar documents
oom Pressurization Con

Siemens BACnet Programmable TEC VAV with Series Fan and 3-Stage Electric Heat Controller

BACnet Terminal Box (VAV) Controller

Siemens BACnet Programmable TEC Constant Volume

Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller

Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller

Siemens BACnet Programmable TEC Unit Conditioner Controller

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller for Smoke Control

Siemens BACnet Programmable TEC Unit Vent Controller

Siemens BACnet Programmable TEC Unit Vent Controller for Smoke Control

BACnet Lab and Pressurized Room Controllers with Off-board Air Modules

Siemens BACnet VAV Actuator

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

Modular Building Controller

PXC Modular Series. Features. Description. Technical Specification Sheet Document No Rev. 1.1, May 2007

TALON Network Manager- 2 & 6 Express

Power Modular Equipment Controller

PXC Modular Series. Features. Description. Technical Specification Sheet Document No July 24, 2012

TX-I/O Product Range. Description. Technical Specification Sheet Document No July 18, 2013

TX-I/O Product Range. Features. Description. Technical Specification Sheet Document No January 24, 2007

TX-I/O Product Range. Description. Technical Specification Sheet Document No February 20, 2018

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

TC Compact Series Unitary Equipment Controller

Compact Series Unitary Equipment Controller

Tracer Controls. Tracer MP501 Controller BAS-PRC008-EN. January 2005

FUME HOOD CONTROLLER (FHC)

Tracer Controls. Tracer MP.501 Controller BAS-PRC008-EN. June 2001

Room Pressurization Controller Pneumatic Output

Airflow Pressure Sensor

TC-9102 Terminal Controller

TC Modular Series for BACnet Networks

FXVMA Variable Air Volume (VAV) Box Controller

BACnet PTEC Heat Pump Multi-Stage Controller. Control Applications. Product Description. Product Numbers. Warning/Caution Notation

DX-9100 Digital Controller, Version 2

TEC Unit Conditioner Controller

TEC Terminal Box (VAV) Controller

BACnet PTEC Terminal Box (VAV) Controller. Control Applications. Product Numbers. Product Description. Warning/Caution Notation

Room Pressurization Controller Electronic Output

Tracer Controls. Tracer ZN517 Unitary Controller BAS-PRC012-EN

BACnet PTEC Controller Constant Volume - Cooling Only, Application Application Note Building Technologies

RWD68U Universal Controller

Andover ContinuumTM. b3850 Series Terminal Controllers

Underfloor Controllers

TRUNK TX RX + - S + - S DO LEDS FLN TRUNK TERMINATIONS INPUT/OUTPUT TERMINATIONS TRANSMIT LED

VAV Modular Assembly (VMA) 1410/1420

TX-I/O Product Range. Features. Description. Document No January 24, 2007

Product Catalog. Tracer Controller MP501 BAS-PRC008-EN. May 2012

Tracer Controllers. Tracer MP503 Input/Output Module BAS-PRC009-EN. January 2005

TEC Heat Pump Multi-Stage Controller. Control Applications. Accessories. Product Description. Product Numbers. Warning/Caution Notation

Tracer Controllers. Tracer MP503 Input/Output Module BAS-PRC009-EN. September 2001

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

Product Catalog. Tracer Controls Tracer ZN517 Unitary Control BAS-PRC012-EN. August 2010

TC Compact Series for BACnet Networks

Variable Air Volume Modular Assembly (VMA) 1400 Series

TC Modular Series. Features. Description. Technical Specification Sheet Document No Rev. 1, July 31, 2008

BT300 HVAC Drives. Designed for HVAC. Description. Technical Specification Sheet Document No March 4, 2013

Actuating Terminal Equipment Controller (ATEC) VAV with Reheat. Start-up Procedures Building Technologies Restricted

SECTION REMOTE CONTROL PANELS

TAC Xenta 301. Controller, Freely Programmable

Specification Sheet For electronically commutated motors

SE7600E Series Application Guide

Features and Benefits of XeteX Controls. Other Unit Control Functions. Energy Recovery Functions

TEC VAV with 0-10V AO Heat. Modulation and CO2 Monitoring. Controller. Control Applications. Product Description. Accessories.

599 Series Zone Valve Actuator SF Series Electronic Valve Actuator, 2-position Control

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

599 Series Zone Valve Actuator SF Series Electronic Valve Actuator, 2-position Control

BACnet PTEC Unit Conditioner/Fan Coil P. Controller. Control Applications. Accessories. Product Description. Warning/Caution Notation

LTEC Unit Ventilator DDC Controller

Andover ContinuumTM b3865/866 VAV Controllers with Built-in Actuator

Lab and Central Plant Controller

Smart Equipment Controls (SEC)

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator

LTEC Heat Pump DDC Controller

MS/TP Point Pickup Module Owner's Manual

Datasheet. ECB-PTU Series. 1/14. BACnet B-ASC Powered Terminal Unit Programmable Controllers. Overview

THERMOSTATS & CONTROLLERS

FX Input/Output (I/O) Modules XM07 and XM14

VZ7000 Series. BACnet Commercial Zoning System

BACnet Protocol Implementation Conformance (PIC) Statement

Andover ContinuumTM Infinet II

MANUAL INSTALLATION + SERVICE. Price Intelligent Controller. PIC Series. v400 Issue Date: 12/18/ Price Industries Limited. All rights reserved.

Modular Room Control (MRC) Series Expansion Board

The Infinity TCX 865 programmable Infinet terminal controller is a unique, low-cost VAV box

PXC Modular Series for BACnet Networks

ECON-ZIP-BASE. ZIP Economizer Base Unit. Wiring Diagram USA CANADA LATIN AMERICA / CARIBBEAN

Onboard Inputs and Outputs. Remote User Interface. Integral LCD User Interface

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Floating Control

BT300 HVAC Drives Electronic Bypass (E-Bypass) Options

HARDWARE GUIDE. VAV Zone Controller C1000 Series. Specifications and Operational Guide

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

Actuating Terminal Equipment Controller (ATEC) VAV with Reheat - Cooling and Heating, Application Application Note

Field selectable application type and room module series, via dip-switches on controller

SEZ7000 Series. Wireless Commercial Zoning System

Datasheet ECB /6. BACnet B-ASC 10-Point Programmable Controller. Overview

BACnet. b3867 Terminal Controllers

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

Siemens TEC Extended I/O Controller

QUICK START GUIDE M2000 SERIES rue Charles, Suite 100, Mirabel, QC, J7J 1X9

Transcription:

Technical Specification Sheet Rev. 4, December, 1998 Dual Duct Controller - One Air Velocity Sensor gure 1. Dual Duct Con ontr troll ller One Air Velocity Sen ensor. The Dual Duct Controller (re 1) is an integral part of the APOGEE Automation System. The controller provides high performance Direct Digital Control (DDC) technology for room temperature control in Dual Duct Variable Air Volume (VAV) systems or air volume set points and room temperature control in Constant Volume (CV) systems. The DDC and related components provide a totally electronic control system. The DDC can operate independent, standalone or networked to perform comple HVAC control, monitoring and energy management functions without relying on a higher level processor. The totally electronic approach to temperature control provides the features listed below. Features PID control of HVAC systems to minimize offset and maintain tighter set point control, Unique control algorithms for specific applications. Reports air flow reports in CFM (l/s), HVAC diagnostics through communication with a Portable Operator's Terminal at a room sensor or any field panel, Set points and control parameters are assigned and changed using the Portable Operator's Terminal, Electrically Erasable Programmable Read Only Memory (EEPROM) used for storing set points and control parameters - no battery backup required, Return from power failure without operator intervention, Meets low duct static pressure requirements, Proven DDC architecture; No calibration required, thereby reducing maintenance costs, Separate cooling minimum position, and Separate air volume set points for occupied and unoccupied modes (CV Applications only). Applications Operating independently, or as a part of the DDC can control a variety of pressure independent dual duct terminal bo applications, including: Constant Volume Hot Duct and Cold Duct Damper Control with optional auiliary heat. Constant Volume Hot/Cold Duct and Volume Damper Control with optional auiliary heat. Variable Air Volume Hot Duct and Cold Duct and Damper Control with optional auiliary heat. Variable Air Volume Hot/Cold Duct and Volume Damper Control with optional auiliary heat. Variable Air Volume 2 Position Hot/Cold Duct Damper and Modulating Volume Damper Control. Document No. 149-255P25 Page 1 of 5

Description The DDC consists of a differential pressure transducer and an electronic controller assembly. An Autozero Module is available for mounting on the controller for those applications where uninterrupted airflow is necessary. A Pneumatic Transducer provides control of pneumatic damper and valve actuators. Control algorithms are preprogrammed. The controller is ready to operate after selecting the application and assigning the unit's controller address with the Portable Operator's Terminal. If desired, the operator may use the Portable Operator's Terminal to adjust the air volume set points in CFM (l/s), room temperature set points and other parameters. The controller is designed for operation and modification without vendor assistance. Differential Pressure Transducer removable terminal blocks. The controller assembly is mounted on a plastic track that is mounted directly on the terminal bo. An optional enclosure protects the controller assembly. The controller interfaces with the following eternal devices: Averaging air velocity sensor provided by terminal bo manufacturers. Floating control valve and damper actuators. Temperature sensors (room, duct, immersion, and outside air). Portable Operator's Terminal. APOGEE Automation System. Digital input devices (dry contacts from motion sensors, alarm contacts). Digital output devices (2 position damper motor, electric heat). The averaging air velocity sensor (provided by the terminal bo manufacturer) sends an average air velocity measurement of the duct air velocity to the controller. The air velocity sensor connects to the differential pressure transducer (which is mounted in the DDC) and measures the average differential pressure. This value is converted to actual airflow in CFM (l/s) by the DDC. Temperature Range Measurement Range Measurement Resolution Measurement Accuracy* 300 to 4000 fpm (1.5 to 20 m/s) 200 to 300 fpm (1 to 1.5 m/s) Repeatability 32qF to 122qF (0qC to 50qC) 0 to 4000 fpm (0 to 20 m/s) r4 fpm (r0.02 m/s) r5% of actual reading +12% to -15% of actual reading r8 fpm (0.04 m/s) *All specifications assume an unadjusted flow coefficient of 1. Dual Duct Controller This controller provides all wiring terminations: input/ output, system and local communication and power. The cable from the room sensor connects to the RJ-11 jack on the controller. All other connections are Power Requirements Operating Range Power Consumption Inputs Analog Digital Outputs Dimensions Controlled Temperature Accuracy, Heating or Cooling Ambient Conditions Storage Temperature Operating Temperature Humidity Range Agency Listings UL Listing CSA Certified FCC Compliance Communications Remote Local 19.2 to 27.6 Vac 50 or 60 Hz 3.5 VA (Nominal) to 5.0 VA (Peak) @ 24 Vac (plus loads) 1 room temperature sensor 1 velocity sensor 1 set point (optional) 1 auiliary temperature sensor 2 dry contacts 6 DO 24 Vac optically isolated solid state switches @ 0.5 amp 4-1/8" W 7-3/4" L 1-1/2" H (105 mm 197 mm 38 mm) appro. 3 lbs. (1.35 kg) r 1.5qF (0.9qC) -20qF to 167qF (-29qC 75qC) 32qF to 122qF (0qC to 50qC) 10% to 95% (non-condensing) UL 916, PAZX UL 864, UDTZ LAN Trunk Portable Operator's Terminal Page 2 of 5 Siemens Building Technologies, Inc

Optional Accessories Autozero Module The optional Autozero Module (re 2) is required when continuous operation at occupied flow is required for an area. The Autozero Module is connected to the air velocity inlet ports of the DDC and provides periodic re-calibration of the air velocity transducer without changing air volume being delivered to a room. This re-calibration ensures longterm precise airflow delivery. Power Consumption 1.5 VA @ 24 Vac ma. Dimensions 2-1/2" W 2-1/2" H 1"D (64 mm 64 mm 32 mm) 0.5 lb. (0.2 kg) gure 3. PTS Pneu neumatic Transducer. Dual Duct Controller Communication gure 2. Autozero Module. Pneumatic Transducer The PTS Pneumatic Transducer (re 3) contains the transducers that provide the signal conversion from electronic to pneumatic. The module is piped to the pneumatic actuator and wired to the DDC. This transducer provides for accurate control of pneumatic actuators for precise temperature and air volume control. Maimum Input Pressure Air Consumption Power Consumption Dimensions 30 psi (207 kpa) 0 SCIM 3.6 VA @ 24 Vac ma. 3-1/2" L 2-1/4" W 1-1/2" H (87 mm 57 mm 38 mm) 9 oz (0.3 kg) Up to 32 Dual Duct Controllers or other Terminal Equipment Controllers can be connected to each of the three field panel LAN trunks. Communication with the DDC can be initiated from any APOGEE Automation System field panel on the system network (see re 5). The APOGEE Automation System network does not require additional hardware to connect Terminal Equipment Controllers. When Terminal Equipment Controllers are wired to a field panel, features such as energy management programs, alarm reporting, centralized control, modification of the system database, system-wide troubleshooting and the global commanding of devices are available to them. Portable Operator's Terminal The DOS-based laptop computer serving as the Portable Operator's Terminal can communicate with DDC or any field panel. The terminal connects to the controller, the room temperature sensor associated with the DDC or field panel. The terminal can be used to remotely adjust air volume settings or temperature set points, to troubleshoot and start-up the system. When connected to the RS-232 port of a field panel, the terminal provides system-wide communication. The terminal uses full English language for all functions, eliminating the need to remember coded commands. Siemens Building Technologies, Inc. Page 3 of 5

gure 3. Port rtable Operator's Terminal Sample Display. Product Ordering Information Description Product Part Number Dual Duct Controller One Air Velocity Sensor 540-106 Dual Duct Controller One Air Velocity Sensor with Autozero Module 540-107 Pneumatic Transducer PTS4 Document Ordering Information Specification Shee heet/app pplica cation Bull lletin Part Name Documen ent Part Number Room Temperature Sensors Series 1000 and Series 2000 (interactive) 149-312P25 Analog Sensors 100 K Ohm Thermistor 149-262P25 Electronic Damper Actuator 155-114 (SQR 81.1) or 155-123 (EA 349 Powers Electronic Valve Actuators: VE 339 2-Way Valve 155-120 VE 339 3-Way Valve 155-121 VE VMP 155-116 Electronic Retrofit Actuator 155-122 Page 4 of 5 Siemens Building Technologies, Inc

FLN FLN 1 FLN 2 FLN 3 BLN BLN Status Battery Transmit Receive Receive Receive Receive Transmit Low DI1 1 2 DI2 3 4 DI3 5 6 DI4 7 8 9 10 DI5 11 12 DI5 13 14 DI5 15 16 DI5 AO13 25 + 17 + 26 - AO9 18 - AO14 27 + 19 + 28 - AO10 20 - AO15 29 + AO11 21 + 30-22 - 31 + 23 + AO16 32 - AO12 24-49 53 50 54 51 55 + 24 V 52 56 SHIELD 33 + AI17 34-35 + AI18 36-37 + AI19 38-39 + AI20 40-41 + AI21 42-43 + AI22 44-45 + AI23 46-47 + AI24 48 - C 57 DO25 NO 58 NC 59 C 60 DO26 NO 61 NC 62 C 63 DO27 NO 64 NC 65 C 66 DO28 NO 67 NC 68 C 78 DO32 NO 79 NC 80 BLN EXP STATUS TX TX BLN EXP MODEM BATT RX RX TX LED 2 LED 3 TX RX LED 4 LED 5 LED 6 LED 7 LED 8 LED 9 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 72 F MANAGEMENT LEVEL NETWORK TCP/IP ETHERNET: Nominal 25 Insight Stations Speed: 10 M bps REPORT PRINTER Up to 4 Building Level Networks GRAPHIC WORKSTATION Base or Advanced With Dial Up Option to MLN and/or BLN BUILDING LEVEL NETWORK Peer To Peer Network: Up to 100 Nodes Per Network-Speed: 9600-115K bp C 69 DO29 NO 70 NC 71 C 72 DO30 NO 73 NC 74 C 75 DO31 NO 76 NC 77 Up to 3 Floor Level Networks FLOOR LEVEL NETWORK PORTABLE TERMINAL MODULAR EQUIPMENT MODULAR BUILDING S STANDALONE CONTROL UNIT Up to 3 Floor Level Networks REMOTE BUILDING To FLOOR LEVEL NETWORK Standalone DDC Control Network: Up to 32 Devices Per Network TO INTEGRATION SYSTEMS NT0254R1 Third Party Devices Variable Frequency Drive DIGITAL ENERGY MONITOR (ELECTRICAL) FUME HOOD DISPLAY PANEL FUME HOOD MONITOR LAB ROOM TERMINAL EQUIPMENT Heat Pump Unit Vent Unit Conditioner Terminal Bo Constant Volume Dual Duct-1 AVS Dual Duct-2 AVS Room Pressurization DIGITAL ROOM SENSOR INCLUDING: Lighting Fire and Life Safety Access and Security Power Monitoring Programmable Logic Control Bac Net LON Talk HVAC Devices Other Building Automation Systems APOGEE Automation System Architectures. Information in this document is based on specifications believed correct at the time of publication. The right is reserved to make changes as design improvements are introduced. APOGEE is a trademark of Siemens Building Technologies, Inc. 1998 Siemens Building Technologies, Inc. Siemen ens Buil ilding Techn hnolog ogies, Inc. 1000 Deerfield Parkway Buffalo Grove, IL 60089-4513 Printed in the U.S.A. (origin). Page 5 of 5