Restoring an SP Boot Image

Similar documents
AX150-Series Upgrading FLARE Operating Environment Software March 28, 2006

EMC CLARiiON Server Support Products for Windows INSTALLATION GUIDE P/N REV A05

Release Notes P/N REV A03 January 3, 2006

16/24/48-Port 10/100/1000T + 2/4-Port 100/1000X SFP Managed Switch GS T2S/GS T2S/GS T4S. Quick Installation Guide

16/24-Port 10/100/1000T 802.3at PoE + 2-Port 100/1000X SFP Managed Switch GS P2S GS P2S. Quick Installation Guide

Multi-port Coax + 2-port 10/100/1000T + 2-port. 100/1000X SFP Long Reach PoE over Coaxial. Managed Switch LRP-822CS / LRP-1622CS

L2/L4 Managed Gigabit Ethernet Switch GS-4210 Ultra PoE Series

EMC SAN Copy Command Line Interfaces

48-Port 10/100/1000Base-T with 4 Shared SFP. Managed Gigabit Switch WGSW Quick Installation Guide

Industrial 24-Port 10/100/1000Mbps Managed Gigabit. Switch (-40~75 degrees C) with 4 Shared SFP Ports IGSW-24040T. Quick Installation Guide

Ethernet Interface Module

Industrial L2/L4 Managed Gigabit Switch. With 4-Port 802.3at PoE+ IGS P4T/IGS P4T2S. Quick Installation Guide

28-Port 10/100/1000Mbps with. 4 Shared SFP Managed Gigabit Switch WGSW / WGSW-28040P. Quick Installation Guide

D-Link (Europe) Ltd. 4 th Floor Merit House Edgware Road London HA7 1DP U.K. Tel: Fax:

SCOPIA 100 MCU Quick Start

EMC ControlCenter Navisphere Security ADMINISTRATOR S GUIDE. Version 6.X P/N REV A04

System Manager Unit (SMU) Hardware Reference

L2+ Managed Gigabit/10 Gigabit Ethernet Switch GS-5220 Series

L2+ Managed Gigabit Switch WGSW series

User Manual. DIL/NetPC DNP/2110 Installing an SSH Connection

Troubleshooting Lightweight Access Points

EMC CLARiiON iscsi Server Setup Guide for VMware ESX Server 3i and 3.x Hosts

UTM Content Security Gigabit Gateway CS-950

L2+ 24-Port Gigabit Managed Switch with. Hardware Layer3 IPv4/IPv6 Static Routing GS S8C GS S8CR. Quick Installation Guide

Product Family: Networking Hardware Number: AN-NH-012

L2+ Managed Metro Ethernet Switch MGSW / MGSD Series

Management Security Switch SGSD-1022 / SGSD-1022P SGSW-2840 / SGSW-2840P. Quick Installation Guide

Release Notes P/N REV A01 February 23, 2006

Hardware Installation Guide Installation (x3350)

24-Port 100/1000X SFP + 4-Port 10G SFP+ Managed. Metro Ethernet Switch MGSW-28240F. Quick Installation Guide

TCPWave DDI Virtual Machine Installation Guide

L2+ Managed PoE Switch GS-5220 PoE Series

Cisco TelePresence Video Communication Server. Getting started

Installation and Configuration Guide

24-Port Gigabit with 4 Optional 10G Slots. Layer 3 Managed Stackable Switch XGS Quick Installation Guide

This Technical Note document contains information on these topics:

Configuration Guide. Upgrading AOS Firmware L1-29.1D July 2011

Troubleshooting. General System Checks. Troubleshooting Components. Send documentation comments to

F5 WANJet 200. Quick Start Guide. Quick Start Overview

McAfee Network Security Platform

L2+ Managed LCD Switch GS T2XV(R) / GS T4XV(R) Quick Installation Guide

How to Upgrade or Recover the Firmware of the UC-7400 Series Embedded Computers

Welcome. Unleash Your Phone

DIL/NetPC ADNP/1520 Board Revision 2.1 Installing an SSH Connection User Manual

IFS NS P-4S-2X Quick Start Guide

Silex SD-320AN-03 Serial Server

DRIVER STATION v1.0 UTILITY LOADER Created: 22DEC2008 FIRST DRIVER STATION UTILITY LOADER RE-IMAGE INSTRUCTIONS

Using the Offline Diagnostic Monitor Menu

Technical Note P/N REV A01 November 24, 2008

High Speed Cable Modem

TFC-1600MM Media Conversion System. Management Configuring Guide

L2+ 16-/24-Port Gigabit PoE. + 2-/4-Port 10G SFP+ Managed Switch. with LCD Touch Screen GS P2XV(R)/GS UP2XV(R)

CM500 High Speed Cable Modem User Manual

Firmware Update Release: Firmware Update. Written By: Q-See qplus.dozuki.com/ Page 1 of 9

ilo MP Utilities ilo MP

Lab Powering Up a Switch

IFS POC2502 Series Quick Start Guide

DIL/NetPC DNP/9200 Board Revision 1.1 Installing an SSH Connection User Manual

CM500 High Speed Cable Modem User Manual

SVMi-8E/SVMi-16E Installation

Trimble NetRS - UNAVCO Basic Use Guide

All Rights Reserved. Rev. 1.0, 2003

EMC SAN Copy. Command Line Interface (CLI) Reference P/N REV A15

Cisco TelePresence Video Communication Server. Getting started

Industrial 4G LTE Cellular Gateway ICG-2420-LTE

ZyWALL 10W. Internet Security Gateway. Quick Start Guide Version 3.62 December 2003

SOFTWARE INSTALLATION GUIDE. EZSwitchSetup Software Installation Guide for Brocade G620

Using the Lantronix SGX 5150 Serial Device Server

SCS100/200/400 Quick Start Guide

Total Control System Application Guide

8 TS4-DDH T i g e r S t o p M a n u a l D a t a D o w n l o a d i n g. May 2006 Version 3.5 ~ 4.72 Hardware

ZyWALL 70. Internet Security Appliance. Quick Start Guide Version 3.62 December 2003

SFP GIGABIT MANAGED SWITCH ECO

McAfee Network Security Platform

EMC Celerra NS-120 System (Dual Blade) Installation Guide

Wireless Network Video Recorder

Introduction... 3 Package Contents... 4 VPN100 LEDs... 5 Connecting your VPN Installing USB drivers... 7

Terminology. This document uses the following terms:

Disk and FLARE OE Matrix P/N REV A17 February 22, 2011

EMC CLARiiON iscsi Server Setup Guide for HP-UX

Release Notes P/N REV A01 August 11, 2010

Disk and FLARE OE Matrix PN

48-Port 10/100Mbps + 4 Gigabit TP / 2 SFP. Managed Switch WGSW Quick Installation Guide

Codian IP VCR IP VCR 2200 Series

Troubleshooting 1240AG Series Lightweight Access Points

ez80190 Development Kit Quick Start Guide

4G WiFi M2M Router (NTC-140W Series) Firmware Upgrade Guide

Table of Contents. Cisco Password Recovery Procedure for the Cisco Aironet Equipment

Gigabit Ethernet Switch. Quick Installation Guide MS400834M

EMC Secure Remote Support Device Client for Symmetrix Release 2.00

Setup for LAUSDnet - Windows 95/98/ME Revised 8/1/2001

High Speed Cable Modem

Recovering a NetComm Wireless M2M router via the recovery console. Technical Support Guide

Intel Server RAID Controller U2-1 Integration Guide For Microsoft* Windows NT* 4.0

User Manual FMUX01(A) SNMP Upgrade Procedure

Juniper Secure Analytics Quick Start Guide

LevelOne FNS bay/1usb Soho NAS. User s Manual

HG658 Home Gateway. User Guide HUAWEI TECHNOLOGIES CO., LTD.

Managing Software. Upgrading the Controller Software. Considerations for Upgrading Controller Software

Cajun P333R. Quick Start Guide. Unpack 1. Rack mount (optional) 2. Power up 3. Connect the cables 4. Configure 5. Run Web-based Manager (optional)

Transcription:

AX100-Series Restoring an SP Boot Image Revision A01 June 9, 2004 This document explains how to restore an SP s boot image. Read it when an SP does not start properly and its fault light blinks four times a second. The cause may be that the SP s boot image has been damaged and is unusable. Topics in this document include Definitions... 2 Restoring an SP Boot Image... 3 Recovering an SP Boot Image Using FTP... 11! CAUTION Do not attempt the restoration procedure without the assistance of your authorized service provider. 1

Definitions Definitions Boot partition A reserved space on one disk, mirrored on another disk, that holds the SP s operating system. Each SP loads its operating system from one of its boot partitions when powered up or reset. Image repository A reserved space that holds images you can use to restore an SP s boot image. Primary boot disk The smaller numbered disk in the mirrored boot pair for an SP. For SP A, it is disk 0; for SP B, disk 1. SP boot light The amber status lamp visible from the back of an SP. The speed at which it blinks indicates the SP startup operation, as follows: Every 4 seconds - The SP is running powerup diagnostics. Every second - The SP is running software diagnostics. Four times a second - The SP is starting up (booting). Off - The SP is running normally. Secondary boot disk The greater numbered disk in the mirrored pair for an SP. For SP A, it is disk 2; for SP B, disk 3. Utility partition A reserved space on the first four drives of a storage system that holds software to perform recovery. Locations of Boot and Utility Partitions and Image Repository Disks 0 1 2 3 SP A primary boot partition SP B primary boot partition SP A secondary boot partition SP A secondary boot partition SP B primary utility partition SP A primary utility partition SP B Secondary Utility Partition SP A secondary utility partition Image Repository Image Repository Image Repository What Next? Continue to the next section for information on restoring a boot image. 2 Definitions

Restoring an SP Boot Image Restoring an SP Boot Image This section describes recovering the SP boot image for a storage processor in an AX100 storage system. Follow this procedure if an SP hangs during startup and cannot boot. An SP indicates that it is trying to boot by flashing the amber light on its back panel four times a second. If it cannot boot, it continues flashing the light four times each second. Normally, you can recover an SP s boot image using the steps in this section. But if no valid SP boot image exists on your storage system, you will need to use FTP to load one. If you must use FTP, a step in this section will direct you to the pertinent section. Connecting the Cables 1. Connect the RJ45-DB9 adapter cable and a DB9-DB9 cables together. These were supplied with your storage system. 2. Connect the joined cables between the server or laptop s COM 1 or COM 2 port (the port you chose for Hyperterm above) and the serial port of the SP that will not boot. Figure 1 shows a cable connection between a COM port and SP A. UPS + - Serial 0 0 LAN COM 1 or COM 2 EMC2939 Figure 1 Connecting a Server/Laptop COM Port to an SP Serial Port AX100-Series Restoring an SP Boot Image 3

Restoring an SP Boot Image Starting a Hyperterm Session A Hyperterm session lets you communicate with a device connected over a COM port, such as an SP. 1. To start a Hyperterm session, follow this path: Start > Programs > Accessories > Communications > Hyperterminal 2. When the software asks for a name, create a meaningful name; for example, AX100; then click OK. The software displays a Connect to screen. 3. In the Connect using box, select COM1 or COM2 from the pull-down list. The software displays a settings screen. 4. Select the following settings: Bits per second: 9600 Data bits: 8 Parity: None Stop bits: 1 Flow Control: None 5. Click OK. The Hyperterm session is now running, as you can see from the timer displayed at the lower left of the screen. You will use this session to communicate with the SP. Recovery Procedure 1. Reset the problem SP. The easiest way to do this is to unplug and then plug in the line cord to the SP s power supply. See Figure 2. Be prepared to watch for the alphabetic power-up test display in the Hyperterm window. 4 Restoring an SP Boot Image

Restoring an SP Boot Image Retention Bail EMC2801 Figure 2 Removal of SP Power Cord from Power Supply The SP will begin its boot sequence and run diagnostic tests. Look for an alphabetical sequence to begin. 2. When the alphabetical test starts, press the Esc key as shown next. Press the Esc key here. AX100-Series Restoring an SP Boot Image 5

Restoring an SP Boot Image The screen displays the following message: Contact your Service Representative... 3. Type DB_key (case sensitive) and press Enter to display the Diagnostic Menu. 4. Select DDBS Service Sub-Menu to display the DDBS Service Sub-Menu. AX100 HyperTerminal 5. On the DDBS Service Sub-Menu, select the Utility Partition Boot option. This tells the SP to boot from its Utility Partition. 6 Restoring an SP Boot Image

Restoring an SP Boot Image The SP boots from its utility partition and displays lots of status messages and eventually a status summary as follows. This normally takes 2-4 minutes and might take longer. Be patient. 6. Press Enter to continue to the CLARiiON Utility Toolkit Main Menu. AX100-Series Restoring an SP Boot Image 7

Restoring an SP Boot Image 7. Select Install Images from the menu. The software displays a Select Images to Install screen. 8 Restoring an SP Boot Image

Restoring an SP Boot Image 8. Select the recovery image to install. The correct filename has the form FLARExxx.mif. If there is no filename with the form FLARExxx.mif, then no recovery image exists. You must obtain one from an outside site. You cannot continue with this procedure. Do not type anything now, but skip to the section Recovering an SP Boot Image Using FTP on page 11. After you have specified an image, the software displays the Confirm Image Installation screen. 9. Enter y if the image selection is correct. The software displays the Select Storage Processors to Install screen. 10. Select the SP you want to recover. Choose This SP since this is the SP you physically connected via the serial cable. For example, if you are restoring the image to SP B, select SP B only. Do not try to restore images to both SPs in one procedure. After you have selected an SP, the software copies the image to the boot drives of that SP. It displays a screen similar to the following that shows the percentage copied. The copy may take up to 5 minutes. Be patient. AX100-Series Restoring an SP Boot Image 9

Restoring an SP Boot Image 11. Verify that the operation completed successfully. You will see the word Success as shown above. 12. Press Enter to continue. The software displays the CLARiiON Utility Toolkit Main Menu. 13. Select the Reset Storage Processor option from the Utility Toolkit Menu. The SP boots using the image you selected. It boots three times, and each boot may take up to 3 minutes. Be patient. After the SP reboots, the amber LED on the SP back panel should be off. You can now manage the SP using Navisphere. 14. Disconnect the cables from the SP and the server/laptop and store them in a safe place. 15. Close your Hyperterm session. You have restored an SP boot image. Congratulations. 10 Restoring an SP Boot Image

Recovering an SP Boot Image Using FTP Recovering an SP Boot Image Using FTP This section explains how to load and use an SP boot recovery image using FTP (Internet File Transfer Protocol). Use this procedure with a single SP system if there is no usable recovery image in the storage system. The software is displaying the Select Images to Install screen (without a file of the form FLARExxx.mif) as shown next. 1. Obtain a recovery file, or information on how to access a recovery file, from your authorized service provider. The recovery filename has the form FLARExxxx.mif. 2. On the Select Images to Install screen, press the Enter key without specifying a number. The software displays the Confirm Image Installation screen. 3. Enter n. AX100-Series Restoring an SP Boot Image 11

Recovering an SP Boot Image Using FTP The software displays the CLARiiON Utility Toolkit Screen Main Menu. 4. Select Enable LAN Service Port. The software displays the Enable LAN Service Port screen and prompts for network information. 5. As prompted, enter the IP address, Subnet Mask, and Default Gateway of the SP you connected to the serial port. The software confirms the settings you entered and asks for confirmation. The entire screen, with the information you entered, appears similar to the following. 6. If the settings are correct, enter y. 12 Recovering an SP Boot Image Using FTP

Recovering an SP Boot Image Using FTP 7. Enter y to continue. 8. Open a browser or an FTP client software package. Use the form ftp://ip-address, where ip-address is the SP s IP address; for example, ftp://10.14.17.120. When the software makes the connection, a log-in window appears. 9. At the login prompt, enter the username clariion (if not already present) and the password clariion! 10. Use your browser to select the recovery file obtained from your service provider, and drag and drop it into the FTP window, as shown in the following two screens. AX100-Series Restoring an SP Boot Image 13

Recovering an SP Boot Image Using FTP 11. Return to the CLARiiON Utility Toolkit window, which is still open, and select Install Images. 12. Select the image you just copied using FTP. 13. Confirm your selection. 14. Select the SP you want to recover. Choose This SP since this is the SP you physically connected via the serial cable. For example, if you are restoring the image to SP B, select SP B only. Do not try to restore images to both SPs in one procedure. 14 Recovering an SP Boot Image Using FTP

Recovering an SP Boot Image Using FTP After you select an SP, the software copies the image to the boot drives of that SP. It displays a screen similar to the following that shows the percentage copied. The copy may take up to 5 minutes. Be patient. 15. Verify that the operation completed successfully. You will see the word Success as shown on the screen above. 16. Press Enter to continue. This returns display to the CLARiiON Utility Toolkit Main Menu. 17. Now you can install the SP image in the system repository. This will let you restore the image without using FTP in the unlikely event the SP image becomes unusable again. To install the SP image in the repository: a. Select Image Repository Sub-Menu. b. Select the option Copy files from RAM disk to Image Repository. c. Select the file you just copied using FTP. d. Press Enter to continue. The software copies the image into the repository. AX100-Series Restoring an SP Boot Image 15

Recovering an SP Boot Image Using FTP e. Enter 1 to return to the CLARiiON Utility Toolkit Main Menu. 18. Select the Reset Storage Processor option from the Utility Toolkit Main Menu. The SP boots using the image you selected. It boots three times, and each boot may take up to 3 minutes. Be patient. After the SP reboots, the amber LED on the SP back panel should be off. You can manage the SP using Navisphere. 19. Disconnect the cables from the SP and the server/laptop and store them in a safe place. 20. Close your Hyperterm session. You have restored an SP boot image. Congratulations. Copyright 2004 EMC Corporation. All Rights Reserved. EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without notice. THE INFORMATION IN THIS PUBLICATION IS PROVIDED "AS IS." EMC CORPORATION MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WITH RESPECT TO THE INFORMATION IN THIS PUBLICATION, AND SPECIFICALLY DISCLAIMS IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Use, copying, and distribution of any EMC software described in this publication requires an applicable software license. Trademark Information EMC 2, EMC, CLARiiON, and Navisphere are registered trademarks and Access Logix, SnapView and MirrorView are trademarks of EMC Corporation. All other trademarks mentioned herein are the property of their respective owners. 16 Recovering an SP Boot Image Using FTP