DICOM SR. DICOM Structured Reporting and templates. Herman Oosterwijk, OTech Inc. Connectivity training and consulting.

Similar documents
17 CP Correct SR Encoding Example

Digital Imaging and Communications in Medicine (DICOM) Supplement 23: Structured Reporting Storage SOP Classes

Radiation Dose Structured Reports

DICOM Correction Proposal Form

23 CP Add Tracking Identifier and UID to Segmentation Instances

Technical Publications

Deep dive into SR: Key Object Selection and Radiation Dose Report

DICOM CONFORMANCE STATEMENT

DICOM Structured Reporting

IHE Cardiology Technical Framework Supplement. Evidence Documents Profile. Cardiology Options: Stress Testing CT/MR Angiography

DICOM CONFORMANCE STATEMENT

R2 Cenova 1.2. DICOM Conformance Statement. MAN Rev 001

17 CP Add description and example for ROI distance measurements with coordinates

Perennity AccessBox DICOM Conformance Statement

Caseaccess 1.0 DICOM Conformance Statement

Digital Imaging and Communications in Medicine (DICOM) Supplement 101: HL7 Structured Document Object References

EOS. EOS imaging system. DICOM Conformance Statement [1]

Technical Publications

iconnect Cloud Gateway V. 1.2

DICOM Correction Item

DICOM 3.0 Conformance Statement

InstaPACS / InstaRISPACS / InstaViewer (v Release) DICOM Conformance Statement. Meddiff Technologies Pvt. Ltd.

DICOM Conformance Statement. isite PACS 4.1. CREF Nov 23. Philips Healthcare Informatics

Inobitec DICOM Server (PACS) Conformance Statement. Version: 1.4.x

DICOM Conformance Statement. isite PACS 3.6. CREF Apr Philips Medical Systems Radiology Informatics

SR Object Model (SR-OM) - Towards an API for toolkits

The DICOM standard : a brief overview

Visage. DICOM Conformance Statement

Version 9 DICOM Conformance Statement. Version 3.05, September 2015

POP-Net Essential DICOM Conformance Statement

ClearCanvas Workstation DICOM Conformance Statement

DICOM Conformance Statement

DICOM Conformance Statement

Perennity DICOM edition DICOM Conformance Statement

AGFA HEALTHCARE DICOM Conformance Statement

AGFA HEALTHCARE DICOM Conformance Statement

IHE Cardiology Technical Framework Supplement. Stress Testing Workflow (STRESS) Trial Implementation

Conformance Statements for DICOM PaCentric Connect / Traveler

C-DAC s Medical Informatics Software Development Kit (SDK) for DICOM PS Conformance Statement

26 CP Retire DICOMDIR reference to unencapsulated CDA on media

ClearCanvas Workstation DICOM Conformance Statement

PACSMail. DICOM Conformance Statement. Sybermedica Ltd St John s Innovation Centre Cowley Road Cambridge CB4 0WS

Acuo VNA. DICOM Conformance Statement Version 6.0 March 2018

PACSware Migration Toolkit (MDIG)

Digital Imaging and Communications in Medicine (DICOM) Supplement 114: DICOM Encapsulation of CDA Documents

Exemplary Design of a DICOM Structured Report Template for CBIR Integration into Radiological Routine

DICOM Correction Proposal Form

STaR. DICOM Conformance Statement. September 2009 Version NO COPIES PERMITTED

CoActiv, LLC CoActiv Medical Business Solutions EXAM-PACS Conformance Statement

QAngio XA 7.0. DICOM Conformance Statement

IHE Eye Care Technical Framework Supplement. Key Measurements in DICOM Encapsulated PDF. Revision 1.0 Draft for Public Comment

VM PACS DICOM Conformance Statement

IHE Integration profiles

AGFA HEALTHCARE DICOM Conformance Statement

Technical Publications

SIEMENS. DICOM Conformance Statement

Version 7 DICOM Conformance Statement. Document Version 3.02, June 2009

Technical Publications

DICOM Conformance Statement. Konica Minolta Healthcare Americas, Inc. VZ0162UG

AGFA HEALTHCARE DICOM Conformance Statement

Generating XML Schemas for DICOM Structured Reporting Templates

DICOM Correction Item

DICOM Overview: Stability and Evolution

Galileo CAD. DICOM Conformance Statement Version Copyright by ARCADIA LAB srl

McKesson Radiology DICOM Conformance Statement

McKesson Radiology EXP1

Digital Imaging and Communications in Medicine (DICOM) Supplement 116: 3D X-Ray Storage SOP Class

DICOM Conformance Statement RT Elements Document Revision 3 January 19, Copyright Brainlab AG

Merge iconnect Enterprise Archive V. 9.4

PowerLook AMP DICOM Conformance Statement

DICOM Conformance Statement

DICOM Conformance Statement IDS5 7.2, WISE 7.2, ImageServer/s 7.2

DICOM Conformance Statement Quentry Version 2.0 March 7, Copyright Brainlab AG

Health Engine DICOM Conformance Statement. Internal document number: Date:

DICOM Conformance Statement

DICOM CONFORMANCE STATEMENT FOR ZIOBASE 4.0

ImageBroker 4.1. DICOM Conformance Statement V 1.0. As of Copyright medigration GmbH All rights reserved

DICOM Conformance Statement

DICOM Conformance Statement

Technical Publications

DICOM Conformance Statement. Xcelera R4.1 L1SP1

DICOM Conformance Statement

Software Version 6.0 DICOM Conformance Statement

DICOM CONFORMANCE STATEMENT. BrainLAB PatientBrowser 1.0

DICOM Conformance Statement

RamSoft. PowerServer. DICOM Conformance Statement

DICOM Conformance Statement Radiotherapy Document Revision 2 July 1, Copyright Brainlab AG

DICOM Conformance Statement

DICOM Conformance Statement

Merge DICOM Toolkit TM V

Dx Server for Windows NT DICOM 3.0 Conformance Statement

Technical Publications

Dx Server for Windows NT DICOM 3.0 Conformance Statement

efilm Workstation V. 4.2

DICOM Conformance Statement. Version: 2.X

DICOM Conformance Statement Surgery Document Revision 4 August 26, Copyright Brainlab AG

IHE EYECARE Technical Framework Supplement

Technical Publications

DICOM. Conformance Statement EPIQ 7 and 5 Release 1.8.x Affiniti 70, 50 and 30 Release 1.8.x Rev A 24 April 2017

DICOM Conformance Statement

Transcription:

DICOM Structured Reporting and templates Herman Oosterwijk, OTech Inc. Connectivity training and consulting www.otechimg.com SPIE 2001 slide A 1-1 Agenda: SR structure SR templates (Note: D. Clunie s book (www.pixelmed.com) is an excellent source) SPIE 2001 slide A 1-2 PAGE: 3-1

Structured Reporting: Why yet another way of encapsulating reports? HL/7 has limited context information No relationship and/or references to DICOM Waveforms, Images, Presentation States) No structure present (reqd for CAD) Not very suitable for outcome measurements No tagging clinically significant images with context information SPIE 2001 slide A 1-3 Structured Reporting examples: CT/MR: Text, selected images, spatial coordinates; after exam Ultrasound: Measurements; during exam CAD: machine generates output: mammography, lung nodule detection, etc. Endoscopy: Observations; during exam SPIE 2001 slide A 1-4 PAGE: 3-2

Structured Reporting examples Cath Lab: 1 Procedure Log: time-stamped record of all events that occur during a procedure. 2 Hemodynamics Report: detail of scientific findings from waveforms and other measurements 3 QCA/QVA Report: analysis of the x-ray angiographic images 4 Electrocardiography Report: findings associated with an ECG 5 Cardiac Cath Report: overall clinical results of the catheterization procedure. SPIE 2001 slide A 1-5 Structured Reporting: Nested tree structure: SR Document 1 contains 1-n Content Item Observation Other Context or Content 1 related to 0-n SPIE 2001 slide A 1-6 PAGE: 3-3

SR example: Document Root Node CONTAINER " Chest X-ray" (Document Title) has properties Leaf Node CODE "Views = PA and Lateral" contains contains contains contains Content Node CODE "finding = mass" Leaf Node IMAGE " Baseline" Heading Node CONTAINER "Conclusions" Heading Node CONTAINER " Specific Image Findings" has properties has properties contains contains Leaf Node NUM " diameter = 1.3 cm" Leaf Node CODE "margination = infiltrative" Content Node CODE "conclusion = probable malignancy" Content node SCOORD inferred from inferred from selected from Has obs context Has obs context Has obs context Leaf Node IMAGE " best illustration of findings" Content Node PNAME " Recording Observer = Smith^John^^Dr^" Content Node UIDREF "Study Instance UID of Evidence Directly Examined by RO = 1.2.3.4.5.6.7.100" Content Node PNAME " Patient-Data-Acquisition Subject = Homer^Jane^^^" * Relationship Modes = By-value = By-reference SPIE 2001 slide A 1-7 14 Structured Reporting Content Items: - plain text - numeric values - codes - dates and times - dates - times - person names - Unique Identifier references - references to: -Images, -Waveforms -Composite Instances - Spatial coordinates - Temporal coordinates - Containers of other items. SPIE 2001 slide A 1-8 PAGE: 3-4

7 SR relationships; for example: : Source Item contains Target Content Item. E.g.: CONTAINER "History" {: TEXT: mother had breast cancer ; IMAGE 36} HAS OBS CONTEXT: Target Content Items shall convey any specialization of Observation Context needed for unambiguous documentation of the Source Content Item. E.g: CONTAINER: "Report" {HAS OBS CONTEXT: PNAME: Recording Observer = Smith^John^^Dr^ } SPIE 2001 slide A 1-9 A structure within the SR structure is needed, i.e. templates otherwise: Almost infinite number of variations for SCU: makes it really hard for SCP Allow potentially straight forward XML conversion and/or generic/standard display formats SPIE 2001 slide A 1-10 PAGE: 3-5

How to create better compatibility: 1. Distinguish between SR SOP Classes: Basic Enhanced Comprehensive 2. Use Templates (TID xxx: DICOM part 16) 3. Generate new SOP Classes, requiring template support, which is a specialization of the SR SOP classes e.g.: Mammography Computer-Aided Detection SR SOP Class (suppl 50) SPIE 2001 slide A 1-11 Key Object Note: IE Module Reference Usage Patient Patient C.7.1.1 M Specimen Identification C.7.1.2 C - Required if the Observation Subject is a Specimen Study General Study C.7.2.1 M Patient Study C.7.2.2 U Series KN Document Series C.17.6.1 M Equipment General Equipment C.7.5.1 M Document KN Document General C.17.6.2 M SR Document Content C.17.3 M SOP Common C.12.1 M SPIE 2001 slide A 1-12 PAGE: 3-6

Key Object Note: KN DOCUMENT SERIES MODULE ATTRIBUTES Attribute Name Tag Type Attribute Description KN DOCUMENT SERIES MODULE ATTRIBUTES Modality (0008,0060) 1 Modality type. Enumerated Value: KN = Key Object Note Series Instance UID (0020,000E ) 1 Unique identifier of the Series. Series Number (0020,0011) 1 A number that identifies the Series. Referenced Study Component Sequence (0008,1111) 2 Uniquely identifies the Performed Procedure Step SOP Instance for which the Series is created. Only a single Item shall be permitted in this sequence. SPIE 2001 slide A 1-13 SR example (Key Image-Object Note): Document Title HAS OBS CONTEXT 1 Observation Context (See figure 5.3-5) 1 1-n Key Image Description (TEXT) Image Reference (IMAGE) SPIE 2001 slide A 1-14 PAGE: 3-7

SR example (mammo): Document Root Image Library HAS PROPERTIES CAD Processing and Findings Summary (CODE) INFERRED FROM Summary of Detections (CODE) Summary of Analyses (CODE) INFERRED FROM INFERRED FROM (IMAGE) (IMAGE) Individual Impression/Recommendation Individual Impression/Recommendation HAS ACQUISITION CONTEXT HAS ACQUISITION CONTEXT SPIE 2001 slide A 1-15 Image Library (mammo): Node Code Meaning of Concept Code Meaning or Example TID 1 Mammography Name CAD Report Value nnn1 1.1 Image Library nnn1 1.1.1 IMAGE 1 nnn22 1.1.1.1 Image Laterality Right nnn22 1.1.1.2 Image View Code Sequence Cranio-caudal nnn22 1.1.1.3 Study Date 19980101 nnn22 1.1.2 IMAGE 2 nnn22 1.1.2.1 Image Laterality Left nnn22 1.1.2.2 Image View Code Sequence Cranio-caudal nnn22 1.1.2.3 Study Date 19980101 nnn22 1.1.3 IMAGE 3 nnn22 SPIE 2001 slide A 1-16 PAGE: 3-8

IHE report uses TID 2000: NL Rel with Parent VT Concept Name VM Req Cond Value Type ition Set CONTAINER BCID(7000) Diagnostic Imaging Report Document Titles 1 M Root node > HAS CONCEPT MOD CODE EV (cv,csd, Procedure reported ) 1-n U > HAS CONCEPT MOD INCLUDE ETID(1204) Language of Content Item and Descendants > HAS CONCEPT MOD INCLUDE ETID (1210) Equivalent Meaning of Concept Name 1 M 1-n U > HAS OBS CONTEXT INCLUDE ETID(1001) Observation Context 1 M > CONTAINER BCID(7001) Diagnostic Imaging Report Headings >> CODE BCID(7002) Diagnostic Imaging Report Elements 1-n U 1-n U >> TEXT BCID(7002) Diagnostic Imaging Report 1-n U Elements >> IMAGE BCID(7003) Diagnostic Imaging Report 1-n U Purposes of Reference >> INCLUDE TID(1400) Linear Measurements 1-n U >> INCLUDE TID(1401) Area Measurements 1-n U >> INCLUDE TID(1402) Volume Measurements 1-n U SPIE 2001 slide A 1-17 Comments/Questions: herman@otechimg.com www.otechimg.com has link to public source implementation and examples of SR SPIE 2001 slide A 1-18 PAGE: 3-9