Installation Instructions for the AUTOcard-SA System

Similar documents
INSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM. Doc Rev B

INSTALLATION INSTRUCTIONS FOR THE "LP" MODEL OVATION SYSTEM. Doc Rev B

Doc Rev B CROWN JEWEL TELEPHONE ENTRY SYSTEM INSTALLATION INSTRUCTIONS

Doc Rev B INSTALLATION INSTRUCTIONS FOR ALL. Infinity TELEPHONE ENTRY SYSTEMS (EXCEPT THOSE WITH MULTI-LINK FIRMWARE)

Doc Rev B INSTALLATION INSTRUCTIONS FOR THE OVATION SYSTEMS

Doc Rev B INSTALLATION INSTRUCTIONS FOR THE "NO PHONE BILL" INTERFACE

PIB300 and PIB301 User Guide. Installation and operation instructions for Panel Interface Board

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries

DESIGN GUIDE FOR INFINITY SYSTEMS

INSTALLATION INSTRUCTIONS

*520886* IntelliTouch Pool & Spa Control System MobileTouch Wireless Controller. User s and Installation Guide. P/N Rev A

3G Cell Modem Upgrade

Enclosure TS-530 User Manual

Installation Instructions

PRO-HC IRRIGATION CONTROLLER

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

FCC Regulatory Information

Now with Picture Memory

Innovative Circuit Technology Ltd.

Mounting and Operating Instructions (Simple Programming) Art.No..: , published: 10/2003

5 B&W Rear View System Camera

DP-222Q Color Video Door Phone Manual

INSOMNIAC CIA G-600 Gateway Installation Manual P/N CIA Revision 1.0 Date Code:

DP-222Q Color Video Door Phone Manual

Laser Stakes. FarmTek. Laser Positioning System For Barrels and Poles. User s Manual. Sport Timing Specialists

InnoMedia ipbx-400. Quick Install Guide.

Bluetooth Option Installation Instructions

InnoMedia ESBC B. Quick Install Guide. 1

The Solution. Multi-Input Module IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

Server Paging System

Instruction Manual. for. Audio Ape Remotes. 1

Industrial RFID Reader

Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection

Satellite INSTALLATION GUIDE

Owner s Manual. Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices

AK-21. Digital Keyless Entry System. Installation and Programming Instructions

DP-234Q (NTSC) DP-734Q (PAL) Hands-Free Video Door Phone Manual

4 Message Paging System

6 10/100/1000TX + 2G Fiber Industrial Ethernet Switch User Manual

Before you get started

Installation Operation

EntraGuard Bronze. Quick Start Guide. Telephone Entry. 1.0 Specifications. 2.0 Unit Installation

Quick Start Installation Guide

Wireless Temperature Module

Charging Pad / Charging Stand

HES-3109 SERIES 9 PORTS 10/100/1000BASE-T MANAGEMENT ETHERNET SWITCH

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

Lantech. IPGS-0204DSFP 4 10/100/1000T PoE at/af + 2 Dual Speed SFP Industrial Unmanaged Switch

IWMR-3002 Industrial Multifunction VPN Router w/up to 2x WiFi 11ac + up to 2 LTE 4G + 2/4 serial ports + 2 Gigabit Ethernet Switch

COBALT C INSTALLATION GUIDE RFID CONTROLLER ESCORT MEMORY SYSTEMS. High Frequency Passive Radio Frequency Identification Controller

Cardax Prox Plus Mifare Reader

Hardened Ethernet to VDSL2 Extender. User Guide. Revision History. Industrial Ethernet to VDSL2 Extender with Wide Operating Temp. Rev.1.

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

KS-SB200 BOOM BOX INSTRUCTIONS LVT B [J]

TruPortal Dual Door Interface Module Quick Reference

Installation Instructions Installation Guidelines. Product Summary. For the maximum number of bus devices and touchpads per panel see Table 1.

1101 Universal Transmitter

3228 Station Port FXS Doorphone

Lantech IPGC-0101DSFP. User Manual. 10/100/1000T (PoE at) to 100/1000M SFP Industrial Switch Converter

myturf BaseStation Kit Wireless Hourmeter System

Wireless Inspection Camera and LCD Display Instruction Manual

NEW ERA METER. Installation & Operation Guide NE METER

InnoMedia ESBC B. Quick Install Guide. 1

Smart Stack Paging System

Clipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems

Installation instructions RF-identification system with integrated AS-i slave DTSLF / / 2010

SuperBus 2000 Phone Interface/Voice Module Installation Instructions

CA-A480-A Elevator Controller. Reference & Installation Manual

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

Telephone Line Monitor USER GUIDE

Interface Converter. Installation Manual IC485S IC485SGB IC485SEU. RS-232 to RS-485/422 Serial Interface Converter

PACKAGE CONTENTS SPECIFICATIONS PRODUCT DIAGRAM

INSTALLATION GUIDE DM-20 English Version 1.10 EN DM20 V1.10A

USB Port Hub HO

N331 Wireless Mini Optical Mouse User s Guide

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

Deluxe In/Out Remote Thermometer with Trend Chart

Q WIEGAND EXPANSION MODULE

WS must be used in a temperature controlled place. It is compliant to ETS Class T

LNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input.

ALTAI C1N SUPER WIFI CPE INSTALLATION GUIDE. Version 1.0 Date: September, Altai Technologies Ltd. All rights reserved

X-12s Users Manual. X-12s User Manual Revisions Revision Description Initial release. Xytronix Research & Design, Inc.

InnoMedia ESBC B. Quick Install Guide. 1

AX3000 Platine Terminal Ethernet TCP/IP

IN-E1004 Encoder Hardware Manual

Cardax FT Controller 3000

For More Product Information On This Other Arcade and Amusment Products, Visit :

3G Cell Modem Installation and User Guide

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

MXHP-H500 (Hub) Owner s Manual v.1.0

Lantech. IPGS-0005T /100/1000T PoE at T Industrial Unmanaged Switch. User Manual

DH GHz Digital Wireless Headphone. User s Manual. Please read before using the equipment. Please visit for details.

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

BAR-USB-SW. Installation Guide. Barcode Swipe Reader. and BAR-USB-SWI

PACKAGE CONTENTS SPECIFICATIONS

Control different load types with one device

CI-1 and CI-8. Communications Interface Betsy Ross Drive Santa Clara, CA (408) FAX (408) P/N Rev.

Bluetooth Enabled Access Control MODEL BG-FE. Operating Instructions

Documentation on all Paxton products can be found on our web site -

C ookie User Manual BC

Transcription:

Installation Instructions for the AUTOcard-SA System IMPORTANT NOTICE The AUTOcard-SA system is a very reliable and easy to use system. However, damage could occur if it is installed incorrectly. In particular, it is critical that the AUTOcard-SA system is grounded properly. The AUTOcard-SA system contains static sensitive components that can be damaged if the system is subjected to static discharge and is not properly grounded. Incorrect installation also invalidates the system s warranty. Therefore, we ask that you take the time to read these instructions very carefully before attempting to install the system.

2 Contents Contents AUTOcard-SA Accessories 3 Remote Monopole Antenna 3 Remote Corner Reflector Antenna 3 In-Line Amplifier 3 In-Line Attenuator 3 Basic Installation Hints and Rules 4 Pulling Cables and Mounting the Cabinet 5 Pulling Cables 5 Mounting the Cabinet 5 Making Basic Connections 6 Installing Additional Features 7 Testing and Adjusting the Unit 9 Verifying the Dip Switch Position 9 Testing the Power Level 9 Testing the Receiver 9 Testing the Gate/Door Operation 9 Appendix 10 AUTOcard-SA Controller Board 10 FCC Requirements 11 Installation 11 Radio Frequency Interference 11 ICC Requirements 11

AUTOcard-SA Accessories 3 AUTOcard-SA Accessories If you are installing your AUTOcard-SA system in an area where radio reception may be poor or limited, it is recommended that you install one or more of the following accessories to the system. Remote Monopole Antenna For installations in which the antenna needs to be installed away from the system, Sentex Systems offers a remote monopole antenna. The remote monopole antenna enables the installation of an antenna high above the ground and/or existing structures without the need for mounting the receiver cabinet in a hard to reach place. The remote monopole antenna can be installed up to 15 feet from the system. Remote Corner Reflector Antenna For installations in which the signal reception needs to be constricted to a specific area, Sentex Systems offers a remote corner reflector antenna. This antenna is a small mast-mounted unit that connects directly to the AUTOcard-SA receiver and should be mounted at least 8 feet above the ground or existing structures. If the cable between the remote corner reflector antenna and the receiver is more than 15 feet in length, it is recommended that an in-line amplifier be connected to the cable. In-Line Amplifier If the remote monopole antenna or the remote corner reflector antenna have more than 15 feet of cable between the antenna and the receiver, an in-line amplifier should be connected to the cable. An in-line amplifier will boost the received antenna signal by a factor of about 1.8 (It should be noted that the amplifier will not only boost all radio signals, but also ALL electrical noise.) The amplifier runs off 115-Volts A.C. and should either be installed in an indoor location (or in a protective weatherproof box). In-Line Attenuator If installing an AUTOcard-SA system in a noisy environment cannot be avoided, a 6 db attenuator is available from Sentex Systems. This product may be useful for correcting overload conditions in the receiver. The attenuator should be installed at the receiver-end of the cable and should not be used in conjunction with an in-line amplifier. NOTE: Although the in-line attenuator corrects overload conditions, it will also seriously reduce the reception range of the receiver. Therefore, this product is not recommended for installation that require a wide reception range.

4 Basic Installation Hints and Rules Basic Installation Hints and Rules PLEASE READ THIS SECTION CAREFULLY BEFORE BEGINNING YOUR INSTALLATION. In the sections that follow, detailed procedures are discussed for each step in installing the AUTOcard- SA system. In addition to these specific procedures, there are a number of general hints and rules which will help ensure that your installation is done correctly and efficiently. These are discussed below: 1. GROUND THE SYSTEM AND YOURSELF THOROUGHLY. The AUTOcard-SA system contains a number of static sensitive components which can be damaged by static discharge during installation or during regular use. This type of damage is not covered under Sentex s warranty. A proper earth ground connected to the system s chassis (at the grounding screw shown in the Appendix) will greatly reduce the chances of damage or improper operation. To be effective, the ground connection should be made by running 12 awg copper wire to a good ground point within 12 feet of the system. This ground point must be at an electrical panel, at a metallic cold-water pipe that runs into the earth, or at a grounding rod at least 10 feet in length that is driven into the earth. If you cannot meet these requirements, a ground will be of little value. Nonetheless, you should try to discharge any static before handling the circuit boards. 2. PROVIDE POWER FROM A DEDICATED SOURCE. If you are powering the system from an AC source, be sure that it is solely dedicated to the AUTOcard-SA system. Specifically, the outlet in which you will plug the transformer provided should be wired back to its own circuit breaker. This will prevent two problems: Other equipment cannot introduce spikes, noise, surges, or dips into the power circuit that will affect the AUTOcard-SA system. The AUTOcard-SA s operation will not be affected if any other equipment develops a short circuit across the power line. 3. DO NOT OVERLOAD THE TERMINAL BLOCKS. The terminal blocks used in the AUTOcard- SA system make field wiring simple, but they do have their limits. The terminal blocks are unpluggable and the pins are soldered into the boards. To connect your wires, remove the head from the correct terminal and open the screws. Insert the wire into the correct opening in the front and tighten the screw until the wire is held snugly. A slight tug on the wire will tell you whether or not you have a secure connection. When you have made all connections for a given head, plug it back into the pins designated for that terminal block. 4. READ THE MARKINGS CAREFULLY. The connection points are marked on the boards clearly. Before making any connection, make sure you read the markings and understand what that connection point is made for.

Pulling Cables and Mounting the Cabinet Pulling Cables The following cabling must be run to the AUTOcard-SA Controller board: Pulling Cables and Mounting the Cabinet 5 1. System Power: A 2 conductor cable from the location of the 120 VAC outlet into which you will plug the 12 VAG, 50 VA transformer supplied by Sentex Systems (or a 12VDC power supply that you provide). See Table 1 below for wire size and distances: MAXIMUM ALPHA WIRE NUMBER WIRE SIZE DISTANCE (RECOMMENDED) 75 ft. 18 awg 2421C 150ft. 16 awg 2432C 250 ft. 14 awg 2442C 500 ft. 12 awg 2444C Table 1: Power Wire Distance 2. Door/Gate Control: A 2 conductor 16 to 22 awg cable (recommended cable is Belden #9501 or equivalent) from the door strike, magnetic lock, or gate operator for each of the 3 control relays. 3. Wiring for additional features as required. See page 6 for a complete discussion of the cabling required for the AUTOcard-SA controller s features. Mounting the Cabinet 1. Determine which of the openings into the box (back or bottom) will be used to run wires into the cabinet. If the wires can be pulled through the wall or pedestal on which the unit is to be mounted, you should use the back opening of the box since it provides better protection against tampering and vandalism. If this cannot be accomplished, run the wire through the 3/4 inch conduit into the bottom opening of the cabinet. Be sure to connect the conduit to the unit securely. 2. Remove the circuit board from the unit by removing the screw in the lower left-hand corner and releasing the board from the plastic stand-offs that hold the other three corners. 3. Carefully remove the knockout plug from the back or bottom (depending on which knockout you are using) of the enclosure. 4. Mount the unit on the wall or pedestal securely. Mounting hardware is provided if you are using Sentex System s pedestal mount. Tighten down all four screws/bolts. 5. Pull all your wires into the cabinet (if you are using the bottom opening, attach your conduit securely first) and remount the circuit board(s). 6. Ground the system.

6 Making Basic Connections Making Basic Connections There are two steps for installing the basic AUTOcard-SA system. These steps are as follows: 1. Connect the wires from your door strike(s) and door strike power supply (or whatever other device you are controlling) to TB1. for relay/gate 1, TB2 for relay/gate 2, and TB3 for relay/gate 3 on the controller board (refer to the Appendix). The terminals you will use will depend on what type of device you are controlling, as described below: A. For dry contact closure (most gate operators): Connect one conductor to the N.O. terminal and the other to the COMMON terminal. B. For magnetic locks or normally unlocked strikes: Connect one conductor from your power supply to the N.C. terminal and one conductor from the door strike to the COMMON terminal of the same terminal block. Then, connect the remaining conductors from each source off the board (for example, by using a wire nut). NOTE: In order to prevent voltage spikes generated by magnetic locks or DC powered strikes from being induced into the system, it is strongly recommended that a IN4001 diode is installed across the magnetic lock coil, so that the cathode of the diode (the end with the band) is connected to the positive connection of the coil, and the anode is connected to the negative end of the coil. C. For normally locked strikes: Connect one conductor from your strike power supply to the N.O. terminal and one conductor from the door strike to the COMMON terminal of the same terminal block. Then, connect the remaining conductors from each source by tying them together off the board (for example, by using a wire nut). 2. Connect the system power. You can power the system using AC or DC power. If you are using AC power, connect the two conductor cable to TB5 on the controller board and the other end to the transformer provided with the system. Then plug the transformer into a 120 VAC outlet. CAUTION An excessive run of wire between the system and the transformer or power supply can result in inadequate voltage being delivered to the system due to line loss (refer to Table 1 for wire sizes and maximum distances). Please also refer to point 2 on page 4 of this document for requirements on the use of a dedicated AC power circuit. If you are using DC power, connect the two conductor cable to TB5 on the controller board and the other end to your power supply. Please refer to Table 1 for wire sizes and maximum distances. Then plug the power supply into a 120 VAC outlet. NOTE: The AUTOcard-SA will not trickle charge a battery, so DC power must be supplied by an uninterruptible power supply. Also, the AUTOcard-SA board does not provide a fuse on the DC input, therefore the installer may want to install a fuse between the DC supply and the system during installation.

Installing Additional Features 7 Installing Additional Features The AUTOcard-SA system has a variety of capabilities which may be hooked up at the time of installation. The features discussed in this section are standard on every system. You and your customer just need to decide whether to use them. The installation procedures for all of these additional features are described below: NOTE: It is critical for proper operation of the system that you use the types of cable and grounding procedures specified. If these specifications are not followed, outside sources of electrical interference (such as nearby power control cables or even nearby radio station broadcast towers) may cause erratic operation or processor resetting/lock-up. WARNING Before hooking up any of these features, disconnect power from the unit. 1. AUXILIARY OPENING/REQUEST ACCESS DEVICES: Any device (e.g., Knox box or exit button) that provides contact closure can be hooked up to the following pins on TB4: PINS IN AREA TB4 RELAY THAT WILL BE ACTIVATED EXIT1 and COM RELAY 1 EXIT2 and COM RELAY 2 EXIT3 and COM RELAY 3 Table 2: Connections For Installing Auxiliary Opening/Request Access Devices Use shielded cable and connect the shield to the chassis ground at the ground screw shown in the Appendix. When a contact closure occurs, the system will activate the appropriate relay for the period of time that the customer programs into the system. 2. HOOKING UP A PRINTER: AUTOcard-SA systems are designed to communicate with a standard personal computer printer with a serial interface. The ability to use a printer is a standard feature -you just have to hook it up to either the RS 422 or the RS 232 port. Please refer to the appropriate section below for instructions on how to connect your printer: CONNECTING A RS 232 SERIAL PRINTER If you are connecting an Okidata 184 Turbo serial printer purchased from Sentex Systems, the printer can be located up to 50 feet from the AUTOcard-SA system. For this installation, you will need a 3 conductor, 18 to 24 awg shielded cable (such as Belden Datalene #9925) and a DB25 connector (if you have purchased your printer from Sentex Systems, a DB25 connector is provided with the printer). The first step of this installation is to connect the wires that you pulled to the DB25 connector. With the use of a wire nut, splice each of the wires in your 3-conductor cable to a corresponding wire on the connector. Next, connect the open end of the cable to terminal TB7 on the AUTOcardSA system as shown below: PIN NUMBER ON DB25 TERMINAL ON TB7 CONNECTOR FOR THE PRINTER OF THE CONTROLLER BOARD 3 ( RECEIVE DATA ) TRANSMIT DATA ( XMIT ) 7 ( SIGNAL GROUND ) GROUND ( GND ) 2 ( TRANSMIT DATA ) RECEIVE DATA ( RCV )

8 Installing Additional Features The shield on the cable should be grounded at the AUTOcard-SA s ground screw and these cables should not be part of a larger cable that contains wires used for other purposes. Make sure your printer is running at the same baud rate as your system (refer to the manual titled USING THE MORE ADVANCED FEATURES OF THE AUTOcard-SA SYSTEM on how to program the system s baud rate). You must also make sure that your printer is set for word protocol of 8 data bits, no parity bits, and I stop bit (8-N-I). Consult your printer manual to determine how to set this protocol properly. CONNECTING A RS 422 SERIAL PRINTER If you are connecting an Okidata 184 Turbo serial printer purchased from Sentex Systems, the, printer can be located up to 50 feet from the AUTOcard-SA system. For this installation, you will need a 3 conductor, 18 to 24 awg shielded cable (such as Belden Datalene #9925) and a DB25 connector (if you have purchased your printer from Sentex Systems, a DB25 connector is provided with the printer). The first step of this installation is to remove the flat, 5-hole connector from the end of the starter cable provided by Sentex Systems with the printer (you will not need it for the AUTOcard-SA system). Next, with the use of a wire nut, splice each of the wires in your 3-conductor cable to a corresponding wire on the connector. Connect the open end of the cable to terminal TB6 on the AUTOcard-SA system as shown below: PIN NUMBER ON DB25 TERMINAL ON TB6 CONNECTOR FOR THE PRINTER OF THE CONTROLLER BOARD 5 /OUT 6 OUT 7( GROUND ) GND The shield on the cable should be grounded at the AUTOcard-SA s ground screw and these cables should not be part of a larger cable that contains wires used for other purposes. Make sure your printer is running at the same baud rate as your system (refer to the manual titled USING THE MORE ADVANCED FEATURES OF THE AUTOcard-SA SYSTEM on how to program the system s baud rate). You must also make sure that your printer is set for word protocol of 8 data bits, no parity bits, and I stop bit (8-N-I). Consult your printer manual to determine how to set this protocol properly.

Testing and Adjusting the Unit 9 Testing and Adjusting the Unit Verifying the Dip Switch Position In order for the system to operate properly, it is important that the dip switches in area S1 of the Controller board are in the correct position (refer to the Appendix for location). For normal operation and programming, switch 1 and 2 must be in the OFF position. To display a transmitter number on the seven-segment display, switch 1 must be in the ON position and switch 2 in the OFF position. Testing the Power Level It is important that the incoming power level is within the specifications of the system. If the power level is not within these specifications, you may experience problems with your system. To test the incoming power, connect the negative lead of a meter to TP2 (GND) and the positive lead to TP3 (PNRV). Set your voltmeter to read DC voltage on a 0-20V range and then apply power to the unit. Your power reading should be between 10.5 and 17.5 VDC. If your reading is above or below this range, you should make the proper adjustments so that the power level is in this range. Testing the Receiver The best way to test the receiver s operation is to set the system to display incoming transmitter numbers and then press the button on a transmitter. To test the receiver, follow the steps below: 1. On the Controller board, set dip switch 1 to the ON position. 2. If you are trying to test a two-button transmitter, aim the transmitter towards the receiver and press the left button on the transmitter. If the receiver is operating properly, the system will display the transmitter s seven-digit number on the seven-segment display. 3. If you are trying to test a single button transmitter, aim the transmitter towards the receiver and press the button on the transmitter. If the receiver is operating properly, the system will display the transmitter s seven-digit number on the seven-segment display. 4. Once you have finished testing the receiver, set dip switch 1 back to the OFF position. Testing the Gate/Door Operation The best way to test the gate/door operation of the AUTOcard-SA system is to use the auxiliary open inputs as follows: 1. To test relay 1, either short between the EXIT1 and COM pins of terminal TB4 or, if an exit request device is attached to these same pins, activate the exit request device. If the system is operating properly, the gate/door attached to relay I should open. 2. To test relay 2, either short between the EXIT2 and COM pins of terminal TB4 or, if an exit request device is attached to these same pins, activate the exit request device. If the system is operating properly, the gate/door attached to relay 2 should open. 3. To test relay 3, either short between the EXIT3 and COM pins of terminal TB4 or, if an exit request device is attached to these same pins, activate the exit request device. If the system is operating properly, the gate/door attached to relay 3 should open.

10 Appendix Appendix AUTOcard-SA Controller Board GUIDE TO CONNECTIONS, ADJUSTMENT, AND INDICATORS 1138F1

FCC Requirements 11 FCC Requirements Installation This device complies with part 15, subpart J of the FCC rules. Operation is subject to the two following conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. On the front inside of the cabinet is a label which contains the FCC registration number for the unit, which is DS8AKRCV. Radio Frequency Interference This equipment has been.tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential environment. This equipment generates, uses, and can radiate radio frequency and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. The user may find the following booklet prepared by the FCC helpful: How to Identify and Resolve Radio-Television Interference Problems. This booklet is available from the United States Government Printing Office, Washington D.C., 20402, Stock No. 004-000-00345-4. ICC Requirements All equipment that are certified under this Standard shall be labeled in accordance with RSP-I00, and with the statement: Complies with ISC:RSS-210; en conformité avec ISC:CNR-210. When size does not permit this, the statement may be abbreviated to ISC:RSS/CNR210. This device complies with RSS-210 of Industry and Science Canada. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.

CHATSWORTH, CA COPYRIGHT 2001 ALL RIGHTS RESERVED Visit us at www.sentexsystems.com This document is protected by copyright and may not be copied or adapted without the prior written consent of Sentex. This documentation contains information proprietary to Sentex and such information may not be distributed without the prior written consent of Sentex. The software and firmware included in the Sentex product as they relate to this documentation are also protected by copyright and contain information proprietary to Sentex.