SonoMeter 30 Ultrasonic energy meter for heating and cooling applications

Similar documents
SonoMeter 30 Ultrasonic energy meter for heating and cooling applications

SonoSelect and SonoSafe energy meters

SonoSelect 10 and SonoSafe 10 energy meters

User guide. SonoMeter 30. Ultrasonic energy meter for heating and cooling applications. Danfoss VUIGI102 1

ULTRASONIC WATER METER HYDROSONIS

All it takes to measure, collect and analyze energy consumption in heating and cooling applications

MCX08M2 Programmable controller

MAKING MODERN LIVING POSSIBLE. Installation Guide. Twin Kit 086L

Installation Guide DEVIlink CC Central Controller

DATASHEET ULTRASONIC COMPACT ENERGY METER MODEL 773

Danfoss commercial compressors Secop compressors produced for Danfoss Bluetooth Gateway

EW773 Series Ultrasonic Hydronic Meters FOR HEATING AND COOLING APPLICATIONS

ECL Comfort V a.c. and 24 V a.c.

SONOMETER TM 500 Ultrasonic compact energy meter

DEVIwet 230V room thermostats for hydronic floor heating

The ECL Apex 20 is operated by means of either a PC or the ECL Apex Web Panel. Temperature input signals are based on Pt 1000 or 0-10 V.

AB Axis Industries. Use

VLT Line Filter MCC 107 EMC Filter Series VLT Midi Drive FC 280 (K1 K3)

Level sensor Stainless steel version Model RLT-1000, for industrial applications

Installation and configuration. WebAccess and its modules for ECL Comfort 200 / 300

Easy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI

CI-tronic Reversing contactor Type RCI

60 Ghz - Radar filling level sensor RFM 2000 C4 / R / MD

EW773 Series Ultrasonic Hydronic Meters DN FOR HEATING AND COOLING APPLICATIONS

standard, short, preferential, top

QVE3000.0xx QVE3100.0xx. Flow sensor. for liquids in DN10 25 pipes

EW500 Series Energy Calculators FOR HEATING AND CHILLED WATER ENERGY METERING

80265 series, 3/2 Indirect solenoid actuated poppet valve

living connect and Danfoss Link CC wireless thermostat system. Total temperature control from one central point.

ELECTRONIC CONTROLS & SENSORS. AK-SC255 Fact Sheet Version R Software Software version 02_085

living connect and Danfoss Link CC wireless thermostat system. Total temperature control from one central point.

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

Proximity sensors, block design

Proximity sensors SME-8, for T-slot Technical data Magnetic reed

MAKING MODERN LIVING POSSIBLE AK-255 CO 2. Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Connecting cables for valves, plug pattern ZC, metric screw Type codes

MAKING MODERN LIVING POSSIBLE. Flashing Manual. CD302 and CDS302. Manual

Level Measurement Continuous level measurement - Ultrasonic transmitters

TEMPERATURE AND HUMIDITY TRANSDUCER P18 TYPE USER S MANUAL

Pile Driver Weld Immune Sensors

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

WARNING ELECTRICAL SHOCK HAZARD

imag 4700 Series FLANGED MAGMETER

Operation Manual. Capacitor Boxes adjustable 80 A / 125 A Track, 2,04 μf to 8 μf. Order Number

Protocol interface AK-PI 200 REFRIGERATION AND AIR CONDITIONING. Manual

Series SD-3PB Digital THERMOSTAT + TIMER

Temperature sensors and accessories for heat and cooling measurement points

Operating instructions. Switching amplifier DN0210 DN / / 2015

APS4 Inductive Proximity Sensors

C5 Series Stainless Steel Photoelectric

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES

RTD-W Installation Instructions

Installation Guide Solid State Meter

PHOENIX CONTACT - 05/2007

Immersion Temperature Sensors

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES

Proximity sensors SME-8M, for T-slot Technical data Magnetic reed

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/221

Pressure sensors SDE1, with display

Protocol interface AK-PI 300

E C t y p e - e x a m i n a t i o n C e r t i f i c a t e

Level sensor for monitoring the level of liquid media

Programmable controller MCX152V

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100 SERIES

SM9000. Magnetic-inductive flow meter. Made in Germany

Level Measurement Continuous level measurement - Ultrasonic transmitters

HEAT METER CALCULATOR QALCOMET HEAT 1

AK-SM 720 Boolean logic REFRIGERATION AND AIR CONDITIONING. User guide

ULTRASONIC LEVEL METERS ULM 53L

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

Innovation on the right wavelength. Level measurement in compact tanks using microwave technology.

Technical Datasheet clima RCM-CC

RXTP ROOM TEMPERATURE

SITRANS F flowmeters SITRANS F US. SITRANS FUE950 energy calculator. 4/240 Siemens FI

Installation instructions Inclination sensor EC2019 EC / / 2013

Non-communicating room controllers

ELIMINATOR Hermetic burn-out filter drier Type DAS

imag 4700 Series FLANGED MAGMETER

Installation Guide VLT Programmable I/O MCB 115

ULTRAFLOW 65-T ultrasonic flow sensors with 2.5 m signal cable

T550 (UC50 ) 1. General. 3. Installation. 2. Safety Information Translation. en Installation Instructions

SER-4485-SI-M USER S MANUAL

Float switch For industrial applications Model RLS-1000

Filter Fan Unit LIGHT

Scanner 2000 Steam Mass Flow Transmitter

Signet 2552 Metal Magmeter Flow Sensors

Differential pressure sensor For ventilation and air-conditioning Model A2G-50

Proximity sensors, round design

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

Level monitoring system NT 3500 Technical information / Instruction manual

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES

MAXIMA+ Series Rotary Level Indicator

Technical Datasheet clima RCM-FC 1. Product description

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Mounting System HMS. To the optimized positioning of sensors Simple and stable fixing in the construction process

SECTION THERMAL UTILITY METERING INTERFACE

MV Series AC Powered Photoelectric Sensors

Operating Instruction for Turbine-wheel Flow Meter. Model: DRS

Transcription:

Installation & User Guide SonoMeter 30 Ultrasonic energy meter for heating and cooling applications www.danfoss.com

2 Danfoss Energy Meters 2016.06 VUIGJ102

1. Installation 1.1. Preparation Only qualified personnel may install the equipment, following the requirements listed in this document. More detailed instruction can be found on www.heating.danfoss.com. Note! This product is approved for ambient temperature between 5-55 C, but to ensure optimal conditions for battery it is recommended to install Calculator at max. 45 C. Avoid installation stress from pipes and fittings. Flush the system. 1.2. Identification of installation: Return/Supply pipe installation and flow direction Return pipe installation Flow direction Flow direction Supply pipe installation VUIGJ102 Danfoss Energy Meters 2016.06 3

1.3. Mounting of flow sensor Pipe position: No limitations but avoid positions where air can be collected. Rotation in pipe axis: Flow sensor should be angled in 45 to 315 to avoid air collection in flow sensor. 1.4. Mounting and sealing of calculator Direct mounting on ultrasonic flow sensor housing, turning every 90 (only when the temperature of the flow does not exceed 90 C): a) On the flow sensor with a thread connection b) On the flow sensor with flange connection On the wall: Panel mounting on standard DIN-rail: 4 Danfoss Energy Meters 2016.06 VUIGJ102

Calculator seals 1: Manufacturer adhesive seal-sticker on the access to the adjustment activation jumper -verification seal. 2: Manufacturer adhesive seal-sticker on the fixer of the cover protecting electronic module -manufacturer security seal. 3: Mounting seal after installation. 1.5. Mounting and sealing of temperature sensors Seal Seal Installation recommendations for ball valve mounting and sealing Installation recommendations for direct short temperature sensors Seal Seal Pocket Pocket a) angled 45 b) perpendicular Installation recommendations for pocket temperature sensors with permanently connected signal leads. VUIGJ102 Danfoss Energy Meters 2016.06 5

1.6. Setting up the jumpers (J) The connector J is on the calculator plate between the temperature sensors and pulse input / output connection terminals (see 6.3). Joining or leaving open the connector contacts, you can choose the normal or verification (test) mode, activate the pulse inputs or outputs: Jumper is not set (contacts are opened) NORMAL MODE The first pulse output V1 is active (terminals 52,53). Energy as default. The second pulse output V2 is active (terminals 50,51). Volume as default. Jumper is set (contacts are connected) VERIFICATION (TEST) MODE The first pulse intput V1 is active (terminals 52,53) (Jumper must be removed when operating in TEST mode) The second pulse intput V2 is active (terminals 50,51) (Jumper must be removed when operating in TEST mode) Note: On delivery the heat meter is configured with two outputs. 2. Electrical wiring Wiring diagram 1 Jumper settings: 1: Additional pulse input V2 is on. 2: Additional pulse input V1 is on. T1: flow temperature sensor. T2: return temperature sensor. V1: additional pulse input/output 1. V2: additional pulse input/output 2. 6 Danfoss Energy Meters 2016.06 VUIGJ102

Wiring diagram 2 Connecting the meter to the mains power supply, 24 V AC/DC. 230 V AC to 24 V AC transformer must be used for connection to 230 V AC! Calculator Terminals Connection 5 T1 supply (inlet) temperature sensor 6 T1 supply (inlet) temperature sensor 7 T2 return (outlet) temperature sensor 8 T2 return (outlet) temperature sensor 50 V2 additional pulse input/output GND 51 V2 additional pulse input/output (Volume output for TEST mode) 52 V1 additional pulse input/output GND 53 V1 additional pulse input/output (Energy output for TEST mode) Communication modules Terminals Connection 24, 25 M-bus module (bipolar) 60, 61 12-24 V DC power supply voltage for Modbus and LON (bipolar) 90 RS-485 Modbus RTU module (+) 91 RS-485 Modbus RTU module (-) 96 LON module (line A) 97 LON module (line B) VUIGJ102 Danfoss Energy Meters 2016.06 7

External power supply module Terminals Destination 54 Mains supply 24V AC/DC (bipolar) 55 Mains supply 24V AC/DC (bipolar) 3. Commissioning 3.1. Bleeding 1. Bleed the system until the flow rate display is steady. 2. Make sure no error codes are displayed. 3. Check the display for a plausible indication of flow rate and temperatures. 3.2. IP class Calculator Flow sensor IP65 IP65 for heat meter IP67 for heat and cooling meter 4. Display function overview 4.1. Menu structure L1 Integral parameters 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 L2 Statistical data 2.1 2.2 2.3 2.4 2.5 2.6.1 2.7.1 2xx 2.15.1 Long press L3 Informative parameters 3.1 3.2 3.3 3.4 3.5 3.6.1 3.7 3x 3.15 Short press 8 Danfoss Energy Meters 2016.06 VUIGJ102

4.2. Display symbols Explanation of special symbols: flow is flowing forward (right direction) flow is flowing backwards (wrong direction) no arrow no flow Explanation of other symbols are described in detailed instruction on www.heating.danfoss.com. 4.3. Error codes Error codes may consist of up to 4 symbols. Each symbol may have values 0 8 Code Status of calculator Status of temperature sensor 2 (return pipe) Description 0 - no error, normal operation 1 - warning ending battery life 2 - temperature difference is greater than the permitted limits 4 - temperature difference is less than the permitted limits 8 - electronics failure 0 - no error, normal operation 4 - short circuit 8 - sensor failure (open circuit or short circuit) Status of temperature sensor 1 (flow pipe) 0 - no error, normal operation 4 - short circuit 8 - sensor failure (open circuit or short circuit) Status of flow sensor 0 - no error, normal operation 1 - no signal, flow sensor is empty 2 - flow flows in an reverse direction 4 - flow rate greater than 1.2 qs (are displayed q = 1,2qs) 8 - electronics failure Active error codes are added and simultaneously displayed, if more than one error is detected: 3 - corresponds errors 2 + 1 5 - corresponds errors 4 + 1 7 - corresponds errors 4 + 2 + 1 9 - corresponds errors 8 + 1 A - corresponds errors 8 + 2 B - corresponds errors 8 + 2 + 1 D - corresponds errors 8 + 4 + 1 E - corresponds errors 8 + 4 + 2 F - corresponds errors 8 + 4 + 2 +1 VUIGJ102 Danfoss Energy Meters 2016.06 9

5. Disposal This symbol on the product indicates that it will not be treated as household waste. It must be handed over to the applicable take-back scheme for the recycling of electrical and electronic equipment. For more detailed information about the recycling of this product, please contact your local municipal office. Item Material Disposal Battery PCBA with display AA-cell lithium/thionyl chloride 700 mg lithium Coppered epoxy laminate components soldered on, PC, TPE Approved deposit for lithium batteries Electronic waste Cables Copper with PUR or PVC jackets Cable recovery Flow sensor (incl. transducer and liner) Brass, stainless steel, PPS Metal recovery Transducer PZT, stainless steel, PEI Approved deposit for PZT Other plastic parts PC, PPS, PEI, TPE Plastic recovery 10 Danfoss Energy Meters 2016.06 VUIGJ102

VUIGJ102 Danfoss Energy Meters 2016.06 11

Danfoss A/S Energy Meters Ulvehavevej 61 DK-7100 Vejle Denmark Phone: +45 7488 8500 Fax: +45 7488 8501 heating@danfoss.com www.heating.danfoss.com Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. 12 Danfoss Energy Meters 2016.06 VUIGJ102