Grounding Monitoring Device Series 8485

Similar documents
Grounding Monitoring Device Series 8485

Ground Monitoring Device Series 8485

Grounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071

Linear Luminaire with LED Series EXLUX 6002/1 Version IIB+H2

Terminal Boxes Series 8118

Linear Luminaire with LED Series 6012/5

Tubular Light Fitting with LED Series 6036

Linear Luminaire with LED Series 6412/5

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009

Load Disconnect Switches and Motor Switches

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Micro Limit Switch Series 8064

Position Switches Series 8070

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Control Buttons / Switches for Panel Mounting Series 8003

Control Switches for Panel Mounting Series 8003

Cable End Boxes Series 8146

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Miniature Circuit-Breaker IEC Series 8562

Ethernet CPU Module & Power Module for Zone 1 / Div. 1 Series 9441/12 and 9444/12

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Operating and monitoring systems Thin Client SERIES 500 Device platform EAGLE PM ET-556-TX

Reed sensor For bypass level indicators Model BLR

Loads and Motor Switchgears

Operating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM ET-436-TX

Operating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM MT-436-TX

5 Fieldbus Technology

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

Threaded resistance thermometer Miniature design Model TR10-D

GRP Flameproof Visual Signal Xenon or Steady LED

Resistance thermometer With spring-loaded tip Model TR55

Gas-actuated thermometer Stainless steel version Model 73

Safety instructions Overvoltage protection B81-35

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE PM MT-336-FX

CPU module for zone 2 Series 9442/35

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

PI-EX-ME-2NAM/COC-24VDC

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

2.3. Ex-Linear light fittings for fluorescent lamps. ellk W 58 W / ellm W 36 W (Zone 1, 2, 21, 22)

PI-EX-ME-2NAM/COC-120VAC

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE OS ET-306-FX

Operating and monitoring systems Panel PC SERIES 400 Device platform SHARK ET-438-2FX

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE OS MT-316-TX

Threaded thermocouple Miniature design Model TC10-D

Operating and monitoring systems Panel PC SERIES 400 Device platform SHARK ET-498-2TX

SolConeX Wall-Mounted Socket, 16 A

MRE Series 16 and 32 Amp Multiple Socket Outlets Stationary and Portable. Increased Safety

Safety instructions. IECEx TUN Ex ia IIC T6 Gb

Cradle relay AC. Electrical data Operating data (coil circuit) U N. Explosion protection Marking ATEX. II 2G Ex db e IIC Gb I M2 Ex db e I Mb I N

4 Remote I/O. Digital Output Module 8-Channel Version Series 9475/ from Rev. F

PHOENIX CONTACT - 12/2007

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

XLF. Ex d. - Zones 1, 2, 21, 22 - Obstruction warnings - Stroboscopic lights - Single or double fixtures - Low wind resistance

Supplementary Components WirelessHART products

Bayonet resistance thermometer Model TR53

ATX MRE Series 16 and 32 Amp Multiple Socket Outlets Stationary and Portable. Increased Safety

SMARTLINE RM76 Supplementary instructions

Operating and monitoring systems Panel PC SERIES 400 Device platform SHARK MT-438-1TX

Installation Equipments

Technical Data. General specifications. Rated operating distance s n 3 mm

IECEx Certificate of Conformity

Junction Boxes & Enclosures JBEA and ECEA Series: Aluminum Enclosures Increased Safety

DR7100 SERIES Supplementary instructions

SolConeX extra-low voltage flange socket

Minimum cross sectional area of Conductor mm²

Junction Boxes & Enclosures JBEP and ECEP Series: Undrilled Fiberglass Reinforced Polyester Enclosures Increased Safety

21023, 21025, 2/2 Direct solenoid actuated poppet valves

Inductive sensor with analog output BI15-M30-LI-EXI

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

Level sensor with reed measuring chain Model FLR, for the process industry

Capacitance level switches LS 210 LS 220

EX-PROOF THERMAL ANALOGUE CAMERAS IN COMPACT DESIGN EC-840S-TIC-19A - Series

FLEX Ex Spring Clamp Terminal Base

Technical Information Promonitor NRF560

The 470-Z1 consists of an aluminium enclosure, which has the supply / interface connections either via the bottom side or enclosure back panel.

Resistance thermometer For additional thermowell Model TR10-B

Micro Motion, Inc. Page 1 of 6

Flow Measurement SITRANS F C

T EN TROVIS Electropneumatic Positioner

ExCos-P Pressure sensor 20 Pa Pa

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min.

Series 3730 Type Electropneumatic Positioner

Ex emergency pull-wire switches Ex ZS 71

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

VALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

KINAX WT720 absolute, programmable angular postion transmitter

Explosion Proof Weighing System

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Conveyor Belt Alignment Switches from IDEM

Isolating repeater IRU 420

Dräger Polytron 8200 Stationary gas detector (CatEx)

PC100 - Concept. Advantages in comparison

Threaded resistance thermometer With protection tube Model TR10-C

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Overfill Prevention Controller EUS-2

Standard enclosure for Remote I/O Series 8150

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT

Level limit switch Series RF 3000 Selection list. Overview 2

Transcription:

www.stahl.de > Controlled electrostatic grounding of road tankers and rail cars during loading > Continuous monitoring of correct grounding > The object recognition prevents potential operator errors (with road tankers) > Water jet protected aluminium enclosure IP65 > Two potential-free change-over contacts per channel for signalling > Insulated point of suspension for clamps > Ambient temperature - 55... + 60 C 17198E00 The ground monitoring device ensures the electrostatic grounding of road tankers and rail cars while loading flammable liquids and powder. The device provides a conductive connection to the ground and monitors in parallel the quality of the electrostatic grounding. This guarantees that the electrostatic charge remains at a safe level and that no explosion hazard is generated by uncontrolled energy discharge. The following recommendation requires grounding during loading and recommends interrupting loading in case of incorrect grounding: > CENELEC LC/TR 50404 recommendation for avoiding ignition hazards due to electrostatic charges. > TRGS 727 rules for avoiding ignition hazards as a result of electrostatic charges ATEX / IECEx Zone 0 1 2 20 21 22 Ex i interface x x x x For use in x x x x WebCode 8485A Control Devices /1

Selection Table Version Description Order number Weight kg Monitored electrostatic grounding of tank containers and 8485/111-42 12.100 rail cars during loading Ambient temperature: - 55... + 60 C 12635E00 Single-channel grounding system Monitored electrostatic grounding of tank containers and rail cars during loading Ambient temperature: - 55... + 60 C 8485/112-42 13.100 12633E00 Dual-channel grounding system 10 m ÖLFLEX with cable gland *) Clamp is made of stainless steel Ambient temperature: -50... +60 C 240197 2.900 Clamp with cable 17200E00 10 m SIHF-J with cable gland *); Clamp is made of stainless steel; Ambient temperature: - 55... + 60 C 238969 2.900 Clamp with cable 17130E00 10 m ÖLFLEX with cable gland *); Clamp is made of stainless steel; Ambient temperature : - 30... + 60 C 238970 4.000 Clamp with spiral cable 17199E00 Robust ergonomic grounding clamp, stainless steel, and fast-action plug. Ambient temperature : - 40... + 60 C 238971 2.000 17132E00 Automatic winder with 9 m of oil and petrol resistant cable with robust ergonomic grounding clamp of stainless steel, and fast-action plug, Plastic enclosure 247660 7.300 with automatic cable winder 17637E00 Automatic winder with 20 m of oil and petrol resistant cable with robust ergonomic grounding clamp of stainless steel, and fast-action plug, Aluminium enclosure, protected cable duct with stopper 247671 14.500 with automatic cable winder 17636E00 Robust ergonomic grounding clamp with 150 mm of cable and fast-action plug 247675 0.600 17638E00 Configuration set consisting of infrared adapter with USB port and CD-ROM with configuration software 202511 0.500 /2 Configuration set Control Devices 12643E00 *) Special cable length possible on request (max. 20 m). Price and date of delivery differ from the standard.

Explosion Protection Global (IECEx) Gas and dust IECEx FTZU 15.0031X Ex d ib [ib] IIB T4 Gb Ex ib [ib] tb IIIC T130 C Db Europe (ATEX) Gas and dust FTZÚ 09 ATEX 0059X E II 2 G Ex d [ib] IIB T4 Gb E II 2 D Ex tb IIIC T130 C Db Certifications and certificates Certificates IECEx, ATEX, Kazakhstan (TR), Russia (TR), Belarus (TR) Further parameters Installation in Zones 1, 2, 21, 22 Safety data For signalling contact Max. connectable voltage U i 50 V DC Max. permissible current I i 200 ma Technical Data Electrical data Power supply Rated voltage Nominal current Frequency range Power consumption Output Signalling contact Minimum load Maximum load DC Maximum load AC Operating mode selection per channel LED indication road tankers 20 V DC - 230 V AC 50 ma 40... 60 Hz 10 VA Ex i or Ex e - two potential-free change-over contacts per channel 10 V DC / 100 ma 230 V DC / 0.25 A 40 V DC / 3 A 230 V AC / 3 A Road tanker and rail car recognition by means of DIP switch Selection via DIP switch Operating principle: LED indication Grounding condition with road tanker Clamp is not connected, grounding equipment not in use Reaction of the grounding monitoring device Grounding incorrect Red indicating lamp ON Green indicating lamp OFF Contacts OPEN 10736E00 Clamp is directly grounded, e.g. via the loading platform Grounding incorrect Red indicating lamp ON Green indicating lamp OFF Contacts OPEN 10737E00 Clamps connected to tank vehicle. Grounding ok Red indicating lamp OFF Green indicating lamp ON Contacts CLOSED 10738E00 Clamps connected to tank vehicle. Tank vehicle is grounded subsequently (e.g. via the loading arm). Grounding ok Red indicating lamp OFF Green indicating lamp ON Contacts CLOSED 10739E00 Control Devices /3

Technical Data Mechanical data Enclosure version Flameproof enclosure (Ex d) Degree of protection IP65 Material Enclosure Aluminium Stainless steel Ambient conditions Ambient temperature -55... +60 C Storage temperature -55... +60 C Mounting / Installation Cable glands Cable diameter range 6 12 mm Connection Maximum diameter, single-wire - rigid 2.5 mm 2 - flexible 2.5 mm 2 - flexible, cable end sleeves with plastic cover 1.5 mm 2 - flexible, cable end sleeves without plastic cover 2.5 mm 2 /4 Control Devices

Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations 124 [4,88] 98 [ 3, 86 ] 124 [4,88] 98 [ 3, 86 ] 6 [ 0, 24 ] 225 [ 8, 86] ø 12 [ø 0,47] 6 [ 0, 24 ] 225 [ 8, 86] ø1 2 [ø 0,47] 334 [13,15] 326 [12,83] 180 [ 7, 09 ] 334 [13,15] 326 [12,83] 180 [ 7, 09 ] 272 [ 10, 71] 325 [12, 79] 12758E00 272 [ 10, 71] 325 [12, 79] Single-channel grounding monitoring device 8485/111 Dual-channel grounding monitoring device 8485/112 12759E00 270,50 [10,65] 158 [6,22] 112,50 [4,43] 71 [2,80] 212 [8,35] Z Z 110 [4,33] 80 [3,15] 41,50 [1,63] 90 [3,54] ø 7 ø 7 [ ø 0,28] [ ø 0,28] Cable drum with automatic cable winder (Art. no. 247660) 17658E00 Control Devices /5

Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations 185 [7,28] 30 520 [20,47] 164 [6,46] 160 110 [4,33] 78 [3,07] 60 360 [14,17] Y 182 [7,17] ø10 [ ø 0,39] 75 [2,95] 150 [5,91] 40 [1,57] 160 Y 20 [0,79] 40 [1,57] ø10,50 ø10,50 [ ø 0,41] [ ø 0,41] ø6,50 ø6,50 125,50125,50 54,50 [2,15] [4,94] [4,94] Cable drum with automatic cable winder (order no. 247671) 12053E00 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. /6 Control Devices