DIN Molded Cable Assemblies

Similar documents
The connector system by Amisco includes a complete range of solutions for the most common connections of the coils for solenoid valves.

IP68 Sealed - Mini USB Buccaneer

ELECTRICAL CONNECTORS ALL PRODUCTS

EcoFlex LED Neon Manual

78 Series Electromechanical Relay Selection Guide

400 Series - Mini USB Buccaneer

Telephony Multi-Taps. 9000T-TP Series

Overvoltage Protection

DD1590 Series Proximity Driver. Connection Technology Center, Inc. Vibration Analysis Hardware. DD1590 Series. Proximity Probe Driver.

HyperLink Brand Weatherproof PTZ Camera Lightning and Surge Protector Model: AL-VDP Series

1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM

CONTROL MICROSYSTEMS and 5407 Relay Output Module. Hardware Manual

output devices. connected to the controller. data communications link. relay systems. user program. MECH1500Quiz1ReviewVersion2 Name: Class: Date:

DIGITAL INPUT MODULES, MINIATURE 181 DIGITAL I/O MODULE ACCESSORIES

Posi-Lok Plugs and Panels

Power Electronics. Semiconductor relay / - contactor

IEI emerge MicroNode Install and Setup Guide. Contents

Technical data: Pin Spacing

picofast 4 - Branch Molded Junctions, Standard Wiring

Expansion Unit Catalog Nos , - 152, - 153, - 154, - 156, -E157

Photoelectric Sensors Comet Series

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

Photoelectric Sensors Comet Series

Capacitive Proximity Sensor E2K-X

Plugs (in-line sockets) for solenoid actuated hydraulic valves

Operating voltages up to 40 kvdc Operating current up to 30 Amps Advanced contact technology Silver plated and gold plated contacts available High

APS4 Inductive Proximity Sensors

MODEL 8000MP LEVEL SENSOR

SPECIAL SPECIFICATION 1864 Pole Mounted Cabinet

Kuhnke Technical Data. Contact Details

poles type cable gland type or connection color approvals order no.

Branch PLC. Velocio s Branch PLC

Capacitive Proximity Sensors

Magnetic Style Safety Interlock Switches

Digital Proportional Valve Amplifier

HYDRAULIC DIGITAL CONTROLLER DIN Single or Dual Proportional Outputs Handheld Programmer

Sensor Connectivity Introduction Global Plus Connector Cables Multi-Connector Blocks. Product Selection Guide...

EMC Installation Guide

IEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line K-Line Ordering Informaiton

Never Beaten by Seasons

Three Phase Systems-International PC302-I/MTD

DESINA installation technology

Allen-Bradley PLCs. 100 Programmable Controller Processor Unit -Catalog Nos LPI01, -LP102, -LP103, -LP104 SLC TM. The Unit

UC-2000 Installation Manual Unicorn Computers Technology Limited

Ultrasonic Analog Output Sensors

Item No.: /

Table of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7

The SilverNugget is a servo controller/driver for NEMA 17 & 23 frame microstep motors.

OilCop Component Wiring Installation Manual

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

PN PSTK-120 PowerSwitch Tail 120vac Kit PN PSTK-240 PowerSwitch Tail 240vac Kit

Model 720 Electromechanical Hour Meter

Mating connectors and cable sets for valves and sensors in hydraulics

P r o t e c t o r s C h a p t e r 227

PRODUCT SPECIFICATION. PC Board Relays. Series.

D-Sub SEaled subminiature D connectors, 2.54 mm pitch

PV Rapid Shutdown device

Ultrasonic Analog Output Sensors

Capacitive Prox E2K-X

Enhancing Business Performance

BCC Part Number Matrix Breakdown Balluff cables, cordsets & connectors for industial automation equipment

SAMPLE. MOVs are sometimes referred

C5 Series Stainless Steel Photoelectric

Power & Communication Cables

Software... pg3 File Maintenance Training

Capacitive Prox E2K-X

The SilverNugget is a servo controller/driver for NEMA 34 frame microstep motors.

SPECIAL SPECIFICATION 6146 Fiber Optic RS-232 Data Modem

Standard Buccaneer - USB

FL MC 2000E (SM40) LC

This Datasheet for the IC670GBI002 24VDC BUS INTERFACE UNIT.

Pile Driver Weld Immune Sensors

Mini Contactors & Overloads

WOODINVILLE, WA SUPERSTEP 2100 SERIES SEQUENCING PROPORTIONAL LOAD CONTROLLERS INSTALLATION & OPERATING MANUAL. Models: SLC2102-SLC2112

Ignitron Driver Manual (N = cable length in meters -example IG5F2-10 = unit with a 10 meter cable length)

Features. Sensing range 50 mm mm... Type of light. Light source 3) Wave length. Adjustment 2) PL80A.

Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems

NEW. TURCK Inductive Sensors - Specialty DS20

Male connector; with fixing flanges; 6-pole; pin spacing 5.08 mm / 0.2 in; for screw or similar mounting types; for parallel or perpendicular mounting

CODE 50108, 50110, 50164, 50165

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide

KCH-B KCH-B. Merits. Application examples. Counters for Display of High-speed Addition and Subtraction. Counters. switches to write settings

Tone Generator and Probe

SENSORS AND CABLES HTMSENSORS.COM

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

Series AMEL10-MJZ 10 Watt AC-DC / DC-DC Converter

PFC Mini TM Power Factor Corrected AC-DC Switchers

CONTA-ELECTRONICS. Fuse, component, diode and indicator modules

TOKISTAR LIGHTING INSTRUCTION MANUAL 24 VDC or 24 VAC

CONTROL MICROSYSTEMS Analog Input Module. Hardware Manual

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

VE-53 Sensor Uniaxial / Triaxial Surface and Downhole Velocity Sensor. Operation Manual

4 C/O. Contact material AgNi AgNi gold-plated Nominal contact current Inrush current

TOPJOB S Sensor/Actuator Terminal Blocks Pluggable Signal Level with Push-in CAGE CLAMP Reliability

NT PRESSURE TRANSDUCER MODELS 4100, 4210, 4130, 4230

Product Information. Inductive Proximity Switches IN

Kuhnke Technical Data. Contact Details

DG-800 Stand-Alone Proximity Reader Instruction Manual

Connectors. Precision Controls Kft.

P/N: AX Distribute your control functions directly onto the valve.

Transcription:

DIN 43650 Telephone (973) 586-500 FAX (973) 596-590

DIN 43650 8mm For Solenoid Valve Applications Black PVC Cable & Connector DUAL JUMPED GROUND PINS Molded cable assemblies can be mounted with cable exiting the ground side or opposite. * Four wire units have one ground pin and 3 U shaped pins. Cable exit direction must be specified. 3 Pole ( U" pins & Flat GNDs) Part Numbers Cable Length Poles 0 to 50 VAC/DC 3 Meter (9.8 Feet) 3 CG-N0-000-C0-3N 5 Meter (6.4 Feet) 3 CG-N0-000-C0-5N 3 Meter (9.8 Feet) 4* CG-N03-000-B0-3N Without & Suppression 5 Meter (6.4 Feet) 4* CG-N03-000-B0-5N to 4 VAC/DC 3 Meter (9.8 Feet) 3 CG-N0-VL-C0-3N 5 Meter (6.4 Feet) 3 CG-N0-VL-C0-5N 0 to 0 VAC/DC 3 Meter (9.8 Feet) 3 CG-N0-VL-C0-3N 5 Meter (6.4 Feet) 3 CG-N0-VL-C0-5N Connection Voltage As Listed in Drawing Cable Type HO5VVF Nominal Power 0A Jacket Material Black PVC Test Voltage 50VAC - 300 VDC max. Conductor Size 8/3 AWG Insulation Group VDC 00 /89 Class C Conductor Color Brn,, (Black), Clamping Voltage 4V 4V Nominal Cable OD 6.7mm Clamping Voltage 0V 85V Bend Radius 0 X Cable OD Connector Material Glass Reinforced Polypropylene Center Screw M3 x 8.7mm Protection Rating IP 67 Temperature Range -5 to +70 C Additional products are available from the manufacturer. Please call us with your application needs. 06.0 Telephone (973) 586-500 FAX (973) 596-590

Industrial Form B mm For Solenoid Valve Applications Black PVC Cable & Connector GROUND PIN LOCATION must be specified. Position is noted looking at the face of the connector with the cable exiting down. In the 6:00 position the ground pin is at the bottom. In the :00 position the ground pin is at the top Part Numbers Cable Length :00 (Ground Up) 6:00 (Ground Down) 0 to 50 VAC/DC 3 Meter (9.8 Feet) CM-N0-000-B0-3N CM-N0-000-A0-3N 5 Meter (6.4 Feet) CM-N0-000-B0-5N CM-N0-000-A0-5N Without & Suppression to 4 VAC/DC 3 Meter (9.8 Feet) CM-N0-VL-B0-3N CM-N0-VL-A0-3N 5 Meter (6.4 Feet) CM-N0-VL-B0-5N CM-N0-VL-A0-5N 0 to 0 VAC/DC 3 Meter (9.8 Feet) CM-N0-VL-B0-3N CM-N0-VL-A0-3N 5 Meter (6.4 Feet) CM-N0-VL-B0-5N CM-N0-VL-A0-5N Connection Voltage As Listed in Drawing Cable Type HO5VVF Nominal Power 0A Jacket Material Black PVC Test Voltage 50VAC - 300 VDC max. Conductor Size 8/3 AWG Insulation Group VDC 00 /89 Class C Conductor Color,, Clamping Voltage 4V 4V Nominal Cable OD 6.7mm Clamping Voltage 0V 85V Bend Radius 0 X Cable OD Connector Material Glass Reinforced Polypropylene Center Screw M3 x 8.7mm Protection Rating IP 67 Temperature Range - to +76 F Additional products are available from the manufacturer. Please call us with your application needs. 06.04 Telephone (973) 586-500 FAX (973) 596-590

Industrial Form C 9.4mm For Solenoid Valve Applications Black PVC Cable & Connector 9.4 9.4 DUAL JUMPED GROUND PINS Molded cable assemblies can be mounted with cable exiting the ground side or opposite. * Four wire units have one ground pin and 3 U shaped pins. Cable exit direction must be specified. Part Numbers Cable Length Poles 3 Pole (3 Flat Pins) 0 to 50 VAC/DC 3 Meter (9.8 Feet) 3 CP-N0-000-C0-3 5 Meter (6.4 Feet) 3 CP-N0-000-C0-5 3 Meter (9.8 Feet) 4* Without & Suppression 5 Meter (6.4 Feet) 4* to 4 VAC/DC 3 Meter (9.8 Feet) 3 CP-N0-VL-C0-3 5 Meter (6.4 Feet) 3 CP-N0-VL-C0-5 0 to 0 VAC/DC 3 Meter (9.8 Feet) 3 CP-N0-VL-C0-3 5 Meter (6.4 Feet) 3 CP-N0-VL-C0-5 Connection Voltage As Listed in Drawing Cable Type HO3VVF Nominal Power 3A Jacket Material Black PVC Test Voltage 50VAC - 300 VDC max. Conductor Size 0/3 AWG Insulation Group VDC 00 /89 Class C Conductor Color Brn,, (Blk), Clamping Voltage 4V 4V Nominal Cable OD 6.7mm Clamping Voltage 0V 85V Bend Radius 0 X Cable OD Connector Material Glass Reinforced Polypropylene Center Screw M3 x.5mm Protection Rating IP 67 Temperature Range - to +76 F Additional products are available from the manufacturer. Please call us with your application needs. 06.06 Telephone (973) 586-500 FAX (973) 596-590

DIN 43650C 8mm For Solenoid Valve Applications Black PVC Cable & Connector 8 8 DUAL JUMPED GROUND PINS Molded cable assemblies can be mounted with cable exiting the ground side or opposite. * Four wire units have one ground pin and 3 U shaped pins. Cable exit direction must be specified. Part Numbers Cable Length Poles 3 Pole (3 Flat Pins) 0 to 50 VAC/DC 3 Meter (9.8 Feet) 3 CP-N0-000-C0-3 5 Meter (6.4 Feet) 3 CP-N0-000-C0-5 3 Meter (9.8 Feet) 4* Without & Suppression 5 Meter (6.4 Feet) 4* to 4 VAC/DC 3 Meter (9.8 Feet) 3 CP-N0-VL-C0-3 5 Meter (6.4 Feet) 3 CP-N0-VL-C0-5 0 to 0 VAC/DC 3 Meter (9.8 Feet) 3 CP-N0-VL-C0-3 5 Meter (6.4 Feet) 3 CP-N0-VL-C0-5 Connection Voltage As Listed in Drawing Cable Type HO3VVF Nominal Power 3A Jacket Material Black PVC Test Voltage 50VAC - 300 VDC max. Conductor Size 0/3 AWG Insulation Group VDC 00 /89 Class C Conductor Color Brn,, (Blk), Clamping Voltage 4V 34V Nominal Cable OD 6.7mm Clamping Voltage 0V 85V Bend Radius 0 X Cable OD Connector Material Glass Reinforced Polypropylene Center Screw M.5 x.5mm Protection Rating IP 67 Temperature Range - to +76 F Additional products are avaialble from the factory. Please call us with your application needs. 06.08 Telephone (973) 586-500 FAX (973) 596-590

DIN 43650 to M For Distribution Box Applications DIN 43650 A Industrial Form B Industrial Form C DIN 43650 C 8mm mm 9.4mm 8mm Part Numbers Length 0 to 50 VAC/DC.5 Meter.6 Feet Dual Ground Ground Up Dual Ground Dual Ground MD3-CG- N0-000-C0-E MD3-CM- N0-000-B0-E MD3-CP- N0-000-C0-E MD3-CP- N0-000-C0-E Without & Suppression to 4 VAC/DC.5 Meter.6 Feet MD3-CG- N0-VL-C0-E MD3-CM- N0-VL-B0-E MD3-CP- N0-VL-C0-E MD3-CP- N0-VL-C0-E 0 to 0 VAC/DC.5 Meter.6 Feet MD3-CG- N0-VL-C0-E MD3-CM- N0-VL-B0-E MD3-CP- N0-VL-C0-E MD3-CP- N0-VL-C0-E Connection Voltage As Listed in Drawing Cable Type HO5VVF or HO3VVF Nominal Power 3A Jacket Material Black PVC Test Voltage 50VAC - 300 VDC max. Conductor Size 8/3 or 0/3 Insulation Group VDC 00 /89 Class C Conductor Color Brn,, (Blk), Clamping Voltage 4V 34V Nominal Cable OD 6.7mm Clamping Voltage 0V 85V Bend Radius 0 X Cable OD Connector Material Glass Reinforced Polypropylene Center Screw Depending on Connector Protection Rating IP 65; IP 67 on Request Temperature Range - to +76 F Additional products are avaialble from the factory. Please call us with your application needs. Page 06.0 Telephone (973) 586-500 FAX (973) 596-590

Multiple Connector Assemblies For Distribution Box Applications Standard main cable length = 3.3 Feet ( Meter) (Other lengths available upon request) DIN 43650 A Industrial Form B Industrial Form C DIN 43650 C Distance between connectors = 7.9 (00mm) 8mm mm 9.4mm 8mm (Other lengths available upon request). Dual Ground Ground Up Dual Ground Dual Ground Part Numbers Heads 0 to 50 VAC/DC CG-D0-000-C0- CM-D0-000-B0- CP-D0-000-C0- CP-D0-000-C0- Without & 3 CG-30-000-C0- CM-30-000-B0- CP-30-000-C0- CP-30-000-C0-4 CG-40-000-C0- CM-40-000-B0- CP-40-000-C0- CP-40-000-C0- to 4 VAC/DC CG-D0-VL-C0- CM-D0-VL-B0- CP-D0-VL-C0- CP-D0-VL-C0-3 CG-30-VL-C0- CM-30-VL-B0- CP-30-VL-C0- CP-30-VL-C0-4 CG-40-VL-C0- CM-40-VL-B0- CP-40-VL-C0- CP-40-VL-C0-0 to 0 VAC/DC CG-D0-VL-C0- CM-D0-VL-B0- CP-D0-VL-C0- CP-D0-VL-C0-3 CG-30-VL-C0- CM-30-VL-B0- CP-30-VL-C0- CP-30-VL-C0-4 CG-40-VL-C0- CM-40-VL-B0- CP-40-VL-C0- CP-40-VL-C0- Connection Voltage As Listed in Drawing Cable Type HO5VVF or HO3VVF Nominal Power 3A Jacket Material Black PVC Test Voltage 50VAC - 300 VDC max. Conductor Size 8/3 or 0/3 Insulation Group VDC 00 /89 Class C Conductor Color Brn,, (Blk), Clamping Voltage 4V 34V Nominal Cable OD 6.7mm Clamping Voltage 0V 85V Bend Radius 0 X Cable OD Connector Material Glass Reinforced Polypropylene Center Screw Depending on Connector Protection Rating IP 65; IP 67 on Request Temperature Range - to +76 F Additional products are avaialble from the factory. Please call us with your application needs. 06. Telephone (973) 586-500 FAX (973) 596-590

Accessories For Connectors and Center Screws Size Used for Plated Screw Gaskets M.5 x.5 8mm Molded 500-05-000 M.5 x 8.5 8mm Connectors 500-05-00A M3 x.5 9.5mm Molded 650-05-000 M3 x 8.7 9.5mm Connectors 00-05-00A M3 x 8.5 8mm, mm, 0mm Molded 700-05-00B M3 x 3.5 8mm, mm, 0mm Connectors 00-05-000 DIN 43650 A Industrial Form B DIN 43650 C & Micro Mini 8mm mm 8mm & 9.4mm Flat Sectional Flat Sectional Flat Sectional Nitrile Rubber Nitrile Rubber Nitrile Rubber Nitrile Rubber Nitrile Rubber Nitrile Rubber 00-04-00A 00-03-000 300-04-00A 300-03-00A 500-04-00A 500-03-000 Silicone Silicone Silicone Silicone Silicone Silicone 00--000 00-3-000 300--000 300-3-000 500--000 500-3-000 Label Plate Label Plate used on all versions of the molded cable assemblies Center Screw Washer Plastic Washer used with the center screw to provide extra sealing capacity 00-007-000 Additional products are available from the manufacturer. Please call us with your application needs. 06. Telephone (973) 586-500 FAX (973) 596-590

What is DIN? DIN (or Deutsche Industrial Normale) is a series of uniformity standards developed in Germany, which apply to commonly manufactured items. What is DIN 43650? DIN 43650 is the standard for a series of electrical connectors, which are commonly used with solenoid valves (especially those used on valves in hydraulics and pneumatics). Other applications include the connection special sensors, such as pressure switches, filter switches, optical, proximity and limit switches. What does DIN 43650 include? The DIN43650 family consists of 5 connectors: General Information Frequently Asked Questions About DIN43650 Connectors and Assemblies What does the light indicate? The on the top of the connector indicates if the connector is receiving power and is used for diagnostic purposes. Connectors with dual colored s are also available to show the state of pressure and filter switches. Why use surge suppression? In solenoid valve applications, a magnetic field is created around the coil. When the power is turned off (as the coil is de-energized) the remaining magnetic field collapses back onto the coil. This creates an electrical surge, which can exceed 3,000 volts. This happens in both AC and DC applications, with operating voltages as low as volts. The resulting surge can cause component damage (both short and long term) and can create noise problems that can interfere with control and measurement signals. Building in surge suppression into the connector, stops the transient surge at the source. Some solenoid valves offer built in surge suppression, however since heat can effect the performance of surge suppression components, this is not always possible. Although their official names are listed on top, we generally refer to them as 8mm, mm, 0mm, 8mm or 9.4mm, which is the actual spacing between pin # and pin #. How are these connectors applied? Generally, the male connector is attached to the solenoid valve or sensor and the female side connects to the cable. The general rule in applying connectors is that a female connector is used to transfer the power to the male. This prevents the possibility of direct exposure to hot pins, (exposed male pins carrying voltage). Female connectors are offered as shells, which allow you to attach your own cable via screw terminals or in molded cable assembly form, pre-wired with the cable attached to a solid molded plastic connector. Why use a molded assembly? Molded assemblies provide a more secure installation, offer many technical advantages and save installation time, labor and cost. Hand wiring a DIN connector is very labor intensive. Considering the overall cost of the connector, wire and labor, molded cable assemblies are generally much less expensive. What other advantages do molded cable assemblies offer? - Solid plastic construction super durability and resistance to harsh environments - Impact resistant with greater cable strain relief - Cleaner looking installation - Available in all DIN 43650 configurations - Offered in a large range of cable lengths - With (or without) built in indication and surge suppression How does common surge suppression work? Typically simple surge suppression components either re-direct or absorb the transient surge. There are several different components which are commonly used: Suppression Diodes (also called fly-back diodes or avalanche diodes) allow voltage and current to flow in only one direction. Placed in parallel to the load, the diodes react to the surge s polarity and re-direct the spike back to the coil where it dissipates. Diodes offer very good suppression; eliminating most of the surge. The are, however, polarity dependant (if they are installed incorrectly they cause a dead short). They also only work in DC circuits and can cause a release delay problem (the energy directed to the coil may delay the solenoid operation). Varistors (also called VDR s or MOV s) are voltage dependant resistors, which close the circuit once an assigned voltage is exceeded. Placed in parallel to the coil, they redirect any voltage, which is above the assigned or cut off levels, back to the coil where they dissipate. Varistors work for both AC and DC application and are polarity independent. Zener Diodes (also called Z diodes) are also voltage dependant devices which work similarly to Varistors. Resistor-Capacitor Networks (also called RC s and snubbers) absorb the surge and gradually discharge the energy back onto the circuit. 06.5