NH fuse-links gg VAC with striker size 0, 1, 2, 3, 4

Similar documents
Ferrule fuse-links 10x38 gg 400 to 690VAC

Ferrule fuse-links 14x51 am 500 to 690VAC

Ferrule fuse-links 22x58 am 500 to 690VAC

Protistor size 22x58 ar 690VAC (IEC) / 700VAC (UL)

Limitor - PD Back-up Fuses without Controlled Power Dissipation

Protistor size 14x51 gr 690VAC (IEC) / 700VAC (UL)

Protistor size 2x72 and 2x73 ar 550 to 1250VAC (IEC)

Protistor size 14x51 gr 690VAC (IEC) / 700VAC (UL)

Industrial fuses NFC-DIN industrial fuselinks gg and am curves from 0.16 to 1250 A

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS

Semiconductor (AC) fuses

Basic Efficiency. NH Fuse-Bases 3-pole. NH Fuse-Bases up to 1500 V. NH Fuse-Bases 1-pole. NH Fuse-Bases, SILAS

Semi conductor fuses PSC 690 V DIN 43620

SOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES

FUSERBLOC LMDC Fuse combination switches FUSERBLOC Live Maintenance DC

AMP-TRAP Form 101 A15QS

L50QS SERIES HIGH-SPEED ROUND BODY FUSES

ECNR/ECSR Class RK5 Dual-Element Time-Delay Fuses. Catalog Number ECNR (1-600A) 250Vac or Less Catalog Number ECSR (1-600A) 600Vac or Less

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

BSL Size A, 690VAC

Bulletin 194R Fused and Non-Fused Disconnects Product Selection

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

Type 1 Arresters. Use in installations with short-circuit currents up to 100 ka rms DEHN + SÖHNE / protected by ISO 16016

5/2 Product overview. 5/3 Distribution board components. 5/9 Built-in components. 5/17 Mounting components 5. Siemens ET B1 10/2009

Surge Protection Devices Ex9UE2

Bulletin 194R Fused and Non-Fused Disconnects Product Selection

MNS ACS880 Switchgear mounted industrial drives

SR60 Busbar System 2/1 2/2. General Data. 2/3 Busbar routing. 2/7 Mounting components. 2/13 Accessories

4. CIRCUIT BREAKERS. Functional Emergency Switching

10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT

JCK, JCK-A, JCK-B, JCH, JCL, JCL-A, JCL-B, JCG, JCR-A, & JCR-B. R-Rated Fuses For Motor Circuit Protection Medium Voltage.

Now even more application possibilities In all facets of semiconductor protection

Non-Fusible Disconnect Switches

MEDIUM VOLTAGE FUSES. POWR-GARD Fuse Datasheet. 2,400-38,000 VAC Current-Limiting

MINI-PS AC/10-15DC/8

Non-Fusible Disconnect Switches

Miniature Circuit-Breaker IEC Series 8562

TRADITIONAL HIGH-SPEED FUSES

FLQ SERIES MIDGET (10x38mm) FUSES

Magnetic and Hydraulic-Magnetic Circuit Breaker

Siemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A

DC Square-body Fuses Sizes 120 to 123 gr 750V DC

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

DX 3 MCB A / 16 ka 80 A to 125 A (1,5 module per pole)

ABL8MEM12020 regulated SMPS - 1 or 2-phase V AC - 12 V - 2 A

The safest way to switch power on and off in your industrial control panels.

ASCO 920 Remote Control (RC) Switches

W DATA SHEET: RCBO COMBINED MCB AND RCCB SERIES BOLF 1+N

Attachment plug with surge protection for coaxial signal interfaces. Connection: N connector, male/female

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

Reinforced discrimination

Maximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches

SIRCO Load break switches for power distribution from 125 to 5000 A

Diodes or VDR s fitted internally if requested.

Special Purpose Fuses

ABL8REM24050 regulated SMPS - 1 or 2-phase V AC - 24 V - 5 A

UL 98 Fusible Disconnect Switches

ABL8MEM24006 regulated SMPS - 1 or 2-phase V AC - 24 V A

920 Remote Control (RC) Switches

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.

60103 Circuit Breaker

PT 3-PB-ST. Extract from the online catalog. Order No.:

SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

Power Supply, Primary Switch Mode for Universal Use QUINT-PS AC/48DC/5

Product Catalog Special Purpose Fuses. Circuit Protection

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

ABL4RSM24050 regulated SMPS - 1 or 2 phase V AC - 24 V - 5A

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

2 Principle of lightning protection

Overvoltage Protection Devices

9926 Series Branch Rated Circuit Breakers AC Version

TT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.:

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

TeSys D contactors. Selection guide. All types of control system. Rated operational voltage. Rated operational power in AC-3. Auxiliary contacts

Uninterruptible Power Supply Unit for Universal Use QUINT-DC-UPS/24DC/40

ABL8REM24050 regulated SMPS - 1 or 2-phase V AC - 24 V - 5 A

Micro Contactor MA Series

Motor protection relays

onlinecomponents.com

ABR1S102B. Main. Contacts type and composition [Uc] control circuit voltage Control circuit type

Power supply module, bus connection module

Extract from the online catalog SFP 1-5/120AC Commercial data Product description Technical data Standards

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

Electro-Mechanical Counters

Microswitches MS Series

SENTRON. Protective devices Selectivity for 3VA molded case circuit breakers. Introduction. Selectivity - terms and definitions

Current Limiting Protector

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

RATINGS AND SPECIFICATIONS

XB4BK123B5. Product data sheet Characteristics. Complete illuminated selector switch. position stay put 1NO+1NC 24V. Main.

Ice Cube Relays. R2/R4 Plug-in Power Relays... G58 Technical Information... G63. R15 Plug-in Power Relays... G68 Technical Information...

Lightning and Surge Arresters

ABL8REM24030 regulated SMPS - 1 or 2-phase V AC - 24 V - 3 A

Transcription:

NH fuse-links gg - 690VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions according to DIN 43 620 Parts 1 to 4 Lead free contact blades 0% cadmium APPLICATIONS gg: General purpose cable and line protection STANDARDS The NH system is classified among plug-in fuse systems and is composed of: fuse-base (possibly including terminal covers and phase barriers) fuse-link with blade contact fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type gg NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. TECHNICAL DATA OVERVIEW Voltage Range AC... 690 VAC Ampere Range (A) 32... 1250 A Size per Standard Sizes 0 to 4 - with striker Speed/Characteristic gg I.R. AC 80... 120 ka Body Material ceramic Contact Materials copper, silver-plated VDE 0636 Part 201 IEC 60269-1 and -2 EP.MERSEN.COM 1

PRODUCT RANGE Size 0 gg with striker Catalog Reference Rated voltage AC (IEC) Rated current In Rated breaking capacity AC Power dissipation at In Weight NH0GG50V160P-2 NH0GG69V32P-2 P213637 690 V 32 A 80 ka 3.7 W 0.275 kg NH0GG69V35P-2 S214146 690 V 35 A 80 ka 4 W 0.2936 kg NH0GG69V40P-2 W214655 690 V 40 A 80 ka 4.5 W 0.275 kg NH0GG69V50P-2 B215166 690 V 50 A 80 ka 5.2 W 0.275 kg NH0GG69V63P-2 D215674 690 V 63 A 80 ka 6.2 W 0.311 kg NH0GG69V80P-2 J216185 690 V 80 A 80 ka 7.5 W 0.29 kg NH0GG69V100P-2 H216690 690 V 100 A 80 ka 8.5 W 0.275 kg NH0GG50V125P-2 V217207 V 125 A 120 ka 10.7 W 0.2926 kg NH0GG50V160P-2 A217718 V 160 A 120 ka 13.5 W 0.275 kg NH0GG50VP-2 K218233 V A 120 ka 15 W 0.275 kg Size 1 gg with striker Catalog Reference Rated voltage AC (IEC) Rated current In Rated breaking capacity AC Power dissipation at In Weight NH1GG50V355P-2 NH1GG69V80P-2 Y218751 690 V 80 A 80 ka 6.9 W 0.3816 kg NH1GG69V100P-2 M219270 690 V 100 A 80 ka 8.1 W 0.3833 kg NH1GG69V125P-2 P219801 690 V 125 A 80 ka 9.6 W 0.347 kg NH1GG69V160P-2 Z222478 690 V 160 A 80 ka 11.9 W 0.3833 kg NH1GG69VP-2 R22 690 V A 80 ka 14.9 W 0.347 kg NH1GG50V224P-2 Y788 V 224 A 120 ka 16.7 W 0.347 kg NH1GG50V250P-2 Q201333 V 250 A 120 ka 18.7 W 0.3783 kg NH1GG50V315P-2 Z201847 V 315 A 120 ka 25 W 0.347 kg NH1GG50V355P-2 W211067 V 355 A 120 ka 28 W 0.347 kg NH3GG50V630P-2 Size 2 gg with striker Catalog Reference Rated voltage AC (IEC) Rated current In Rated breaking capacity AC Power dissipation at In Weight NH2GG69V125P-2 W212102 690 V 125 A 80 ka 9.5 W 0.564 kg NH2GG69V160P-2 L212622 690 V 160 A 80 ka 11.5 W 0.564 kg NH2GG69VP-2 Y213139 690 V A 80 ka 14.5 W 0.564 kg NH2GG69V224P-2 Q213638 690 V 224 A 80 ka 16 W 0.569 kg NH2GG69V250P-2 T214147 690 V 250 A 80 ka 17.5 W 0.564 kg NH2GG69V315P-2 X214656 690 V 315 A 80 ka 23 W 0.564 kg NH2GG69V355P-2 E215675 V 355 A 120 ka 25 W 0.564 kg NH2GG50V400P-2 K216186 V 400 A 120 ka 29 W 0.564 kg NH2GG50VP-2 W217208 V A 120 ka 39 W 0.6033 kg Size 3 gg with striker Catalog Reference Rated voltage AC (IEC) Rated current In Rated breaking capacity AC Power dissipation at In Weight NH3GG69V315P-2 B217719 690 V 315 A 80 ka 23 W 0.871 kg NH3GG69V355P-2 L218234 690 V 355 A 80 ka 25 W 0.871 kg NH3GG69V400P-2 Z218752 690 V 400 A 80 ka 29 W 0.871 kg NH3GG69VP-2 N219271 690 V A 80 ka 39 W 0.871 kg NH3GG50V630P-2 Q219802 V 630 A 120 ka 47 W 0.871 kg EP.MERSEN.COM 2

PRODUCT RANGE Size 4 gg with striker Catalog Reference Rated voltage AC (IEC) Rated current In Rated breaking capacity AC Power dissipation at In Weight NH4GG69VP-2 S79 690 V A 120 ka 40 W 2.2 kg NH4GG69V630P-2 T80 690 V 630 A 120 ka 53 W 2.2 kg NH4GG69V800P-2 V81 690 V 800 A 120 ka 68 W 2.2 kg NH4GG50VP-2 W82 V A 120 ka 65 W 2.2 kg NH4GG50V1250P-2 X83 V 1250 A 120 ka 61 W 2.2 kg TECHNICAL DATA Size 0 Size 1 Size 2 Size 3 Size 4 gg with striker Rated current 32... A 80... 355 A 125... A 315... 630 A... 1250 A Rated voltage AC... 690 V... 690 V... 690 V... 690 V... 690 V Indication System with striker with striker with striker with striker with striker EP.MERSEN.COM 3

TIME CURRENT CHARACTERISTIC CURVES Size 0-1-2-3, 690V gg Pre-arcing time (s) 300 100 70 50 30 20 10 7 5 3 2 32 A 35 A 40 A 50 A 63 A 80 A 100 A 1 0.7 0.5 0.3 0.2 0.1 0.07 0.05 0.03 0.02 0.01 0.007 0.005 0.003 0.002 0.001 0.0007 0.0005 0.0003 0.0002 0.0001 30 50 70 100 300 RMS value of prospective current (A) +/- 8% 0 0 125 A 160 A A 224 A 250 A 315 A 355 A 400 A A 0 0 0 EP.MERSEN.COM 4

TIME CURRENT CHARACTERISTIC CURVES Size 4, 690V gg Pre-arcing time (s) 300 100 70 50 30 20 10 7 5 3 2 1 0.7 0.5 0.3 0.2 0.1 0.07 0.05 0.03 0.02 0.01 0.007 0.005 0.003 0.002 0.001 0.0007 0.0005 0.0003 0.0002 0.0001 0 0 0 RMS value of prospective current (A) +/- 8% 0 0 00 00 EP.MERSEN.COM 5

TIME CURRENT CHARACTERISTIC CURVES Size 0-1-2-3, V gg Pre-arcing time (s) 300 100 70 50 30 20 10 7 5 3 2 125 A 160 A A 224 A 250 A 315 A 355 A 1 400 A 0.7 0.5 0.3 0.2 0.1 0.07 0.05 0.03 0.02 0.01 0.007 0.005 0.003 0.002 0.001 0.0007 0.0005 0.0003 0.0002 0.0001 100 300 RMS value of prospective current (A) +/- 8% 0 A 630 A 0 0 0 0 00 EP.MERSEN.COM 6

TIME CURRENT CHARACTERISTIC CURVES Size 4, V gg Pre-arcing time (s) 300 100 70 50 30 20 10 7 5 3 2 A 1250 A 1 0.7 0.5 0.3 0.2 0.1 0.07 0.05 0.03 0.02 0.01 0.007 0.005 0.003 0.002 0.001 0.0007 0.0005 0.0003 0.0002 0.0001 0 0 0 RMS value of prospective current (A) +/- 8% 0 0 00 00 00 EP.MERSEN.COM 7

CUT-OFF CURRENT CHARACTERISTIC Size 0-1, 690V gg 0 A 0 160 A Maximum peak let thru current Ic (A) 100 300 lm = 2.3 lp 0 0 0 0 0 00 125 A 100 A 80 A 63 A 50 A 40 A 35 A 32 A 00 00 00 1e+06 50 Hz RMS symmetrical prospective current Ip (A) Size 2-3, 690V gg Maximum peak let thru current Ic (A) 0 0 0 0 0 lm = 2.3 lp 0 0 0 0 0 00 50 Hz RMS symmetrical prospective current Ip (A) 00 A 400 A 355 A 315 A 250 A 224 A A 160 A 125 A 00 00 1e+06 EP.MERSEN.COM 8

CUT-OFF CURRENT CHARACTERISTIC Size 4, 690V gg 00 lm = 2.3 lp 800 A Maximum peak let thru current Ic (A) 0 0 0 0 0 0 0 0 0 0 00 50 Hz RMS symmetrical prospective current Ip (A) 00 630 A A 00 00 1e+06 Size 0-1-2-3, V gg 0 0 lm = 2.3 lp 630 A A Maximum peak let thru current Ic (A) 0 0 0 0 0 0 0 0 00 50 Hz RMS symmetrical prospective current Ip (A) 400 A 355 A 315 A 250 A 224 A A 160 A 125 A 00 00 00 1e+06 EP.MERSEN.COM 9

CUT-OFF CURRENT CHARACTERISTIC Size 4, V gg 00 00 lm = 2.3 lp 1250 A Maximum peak let thru current Ic (A) 0 0 0 0 0 0 0 0 0 00 50 Hz RMS symmetrical prospective current Ip (A) 00 A 00 00 1e+06 EP.MERSEN.COM 10

PRE-ARCING AND OPERATING I²T CHARACTERISTICS Size 0-1-2-3, 690V gg 000 000 000 690V V pre-arcing I²t 000 Rated current (A) 000 00 00 00 00 00 0 0 0 0 0 300 100 32 35 40 50 63 80 Pre-arcing and operating I²t (A²s) 100 125 160 224 250 315 355 400 EP.MERSEN.COM 11

PRE-ARCING AND OPERATING I²T CHARACTERISTICS Size 4, 690V gg 30 000 000 20 000 000 690V V prearcing I²t Rated current (A) 10 000 000 7 000 000 5 000 000 3 000 000 2 000 000 1 000 000 000 000 300 000 000 100 000 630 800 Pre-arcing and operating I²t (A²s) EP.MERSEN.COM 12

PRE-ARCING AND OPERATING I²T CHARACTERISTICS Size 0-1-2-3, V gg 000 000 000 V 380V pre-arcing I²t Rated current (A) 000 000 00 00 00 00 00 0 0 0 0 0 10 000 125 160 224 Pre-arcing and operating I²t (A²s) 250 315 355 400 630 EP.MERSEN.COM 13

PRE-ARCING AND OPERATING I²T CHARACTERISTICS Size 4, V gg 100 000 000 70 000 000 50 000 000 V 400V prearcing I²t 30 000 000 Rated current (A) 0 000 10 000 000 7 000 000 5 000 000 3 000 000 2 000 000 1 000 000 000 000 300 000 000 100 000 1250 Pre-arcing and operating I²t (A²s) EP.MERSEN.COM 14

DIMENSIONS Size 0 (126458) 49.5 10 ± 0.15 0 10-0.3 20 ±0.2 13.1 +0.3 35-0.5 2.75 ± 0.25 Striker is visible after fuse link has operated Ø 5.5 Ø 8 6 ±0.2 15 41.3 16 23.4 Dimensions in mm 72.3 +0.7-0.8 68.3 +0.6-2.1 62.3 +0.4-1.9 63 125.5 +1.5-3 39 ±0.65 15.3 ±0.3 14.4 47 ±0.8 EP.MERSEN.COM 15

DIMENSIONS Size 1 (126503) 20 ±0.2 Ø 5.5 6 ±0.2 54 10 ± 0.15 0 10-0.3 14.2 +0.6 40.2-0.5 2.75 ± 0.25 Striker is visible after fuse link has operated Ø 8 16 44.6 Dimensions in mm 16 22.4 +0.5 78.5-1 67.6 ±1.6 61.6 ±1.4 71 135 ±1.7 13.85 51.5 ±0.9 40 ±0.7 EP.MERSEN.COM 16

DIMENSIONS Size 2 (126505) Ø 5.5 6 ±0.2 62.3 10 ± 0.15 20 ±0.2 +0.5 2.5-0 +0.3 48-0.5 Striker is visible after fuse link has operated Ø 8 14 19.5 56 16 22 Dimensions in mm 67.6 ±1.6 61.6 ±1.4 71 +0.5 78.5-1 150 ±1.7 26.3 ± 0.2 14.4 59.9 ± 1 56 ±1 EP.MERSEN.COM 17

DIMENSIONS Size 3 (126508) 20 2.75 ± 0.24 0 10-0.3 14.5 60 ± 0.8 73 10 6 ± 0.2 24 69 68 ±2.5 Striker is visible after fuse link has operated Dimensions in mm 16 22 62 ±2.5 73 0 73-1.5 150 ±2.5 17.2 32.3 EP.MERSEN.COM 18

DIMENSIONS Size 4 (1037473) 68.5 ±1.4 62.5 ±1.4 22 10 6 2 32 ±0.4 50 ±0.2 87 Ø 8.2 14.5 10 3 100 ±1.8 16 ±0.4 16 ±0.4 20 30.6 (79.5) 30.6 +2 149.5-1.6 100 ±1.8 27.5 8 ±0.1 Ø (5.5) Striker is visible after fuse link has operated Dimensions in mm +2 199.5-1.6 blown 16.6 EP.MERSEN.COM 19