M40e and M160 CIP Installation Instructions

Similar documents
Routing Engine, MCS, and CB Installation Instructions

Switch Interface Board (SIB) Installation Instructions

M5 and M10 Routers Power Supply and Power Cord Component Replacement Instructions

M-series and T-series Routing Engine and MCS Installation Instructions

M-series, MX-series, and T-series Routing Engine and MCS Installation Instructions

SRX 5600 and SRX 5800 Services Gateway Routing Engine Installation Instructions

Removing Components from the MX480 Chassis Before Installing It Without a Lift

Removing Components from the MX960 Chassis Before Installing It Without a Lift

SDRAM Installation Instructions

Quick Start. M160 Internet Router. Juniper Networks, Inc North Mathilda Avenue Sunnyvale, CA USA

Maintaining the Cisco Catalyst 5500 Multiswitch Router

Conversion Instructions for SSG 300M-series Security Devices and J-series Services Routers

Installing and Removing SDRAM and DRAM

PIC and Transceiver Installation Instructions

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Conversion Instructions for SSG 500M-series Security Devices and J-series Services Routers

M160 Internet Router Release Notes

IDENTIFICATION OF VOLATILE AND NON-VOLATILE STORAGE AND SANITIZATION OF SYSTEM COMPONENTS JUNIPER NETWORKS SRX SERIES SERVICES GATEWAY SRX650

SRX 5600 Services Gateway DC Power Supply Installation Instructions

J-series Services Router Crypto Accelerator Module Installation Instructions

How to Set Up Your SRX4100 Services Gateway

Installing the Cisco 2524 and Cisco 2525 Routers

Junos WebApp Secure 5.0 Hardware Guide

QFX10008 Switch Quick Start Guide

Installing Power Modules

Maintaining the Cisco Internet Router

PIX 515/515E. PIX 515/515E Product Overview CHAPTER

Replacing the Power Supply

Remote RMM-1400 Intelligent Remote Site Management Device. Installation Guide

Removing and Installing the ISA and the ISM

Adding or Replacing a PCI Card

Catalyst 6500 Series Wireless LAN Services Module Installation and Verification Note

E1 and T1 RJ-48 Cable Pinouts on page 208. Fast Ethernet 12-port Cable Pinouts on page 211

Managing Individual Components

Installing a Network Module

IDENTIFICATION OF VOLATILE AND NON-VOLATILE STORAGE AND SANITIZATION OF SYSTEM COMPONENTS JUNIPER NETWORKS SRX-SERIES SRX210B

Storage/Control I/O Module

Connect Router to the Network

SwitchBlade Switch Controller Quick Install Guide

Sure Coat Modular Gun Control System Part C: UCS ProfiBus Interface Card. Customer Product Manual Part B

MX240 3D Universal Edge Router Quick Start

ACX2200 Universal Access Routers Quick Start

PIX 520. PIX 520 Product Overview CHAPTER

Installing a Network Module

Installing the Cisco Unified Videoconferencing 3545 MCU

Cisco Internet Router Chassis and Backplane Replacement Instructions

apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May Apple Computer, Inc. All rights reserved.

Rack Installation Instructions

How to Set Up Your SRX550 High Memory Services Gateway

IBM. Rack Installation Instructions

DX 32xx and DX 36xx Quick Start

Maintaining the ERX System

How to Set Up Your SRX300 Services Gateway

apple Service Source Xserve RAID 17 March Apple Computer, Inc. All rights reserved.

Installing the Cisco MDS 9020 Fabric Switch

Installation and Configuration Guide

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

DX Application Acceleration Platform Quick Start

To connect the AC adapter:

1. Carefully unpack the um260 s shipping carton and check the contents for damage.

Installing a Network Module

Introduction. Overview

Installing the Interface Line Card in the Cisco cbr Chassis 6

TX Matrix Cable Shelf Assembly Installation Instructions

Removing and Replacing FRUs from the Cisco ASR 1001-X Router

INSTALLATION INSTRUCTIONS FOR THE BV10-100/1000

Snap Server 4400 Power Supply

IDENTIFICATION OF VOLATILE AND NON-VOLATILE STORAGE AND SANITIZATION OF SYSTEM COMPONENTS JUNIPER NETWORKS SRX-SERIES SRX240H

Infinity 1U 19 Converter Shelf Models: J L217 - Individual +24V Inputs Bulk -48V Output L218 - Individual -48V Input Bulk+24V Output

E320 Quick Start Guide

XTM 1050 Replacement Parts Installation

Juniper Secure Analytics Quick Start Guide

Installing or Replacing Modules, Fan Trays, and Power Supplies

Installing the Cisco SFS 3504 Server Switch

Field Service Guide Supplement for the NS 7000/030

Quick Start Guide. Industrial Managed Gigabit Ethernet PoE+ Switch LPH2008A-4GSFP

How to Set Up Your SRX340 Services Gateway

Installing the Cisco XR Router

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start

H3C S12500 Routing Switch Series

Next Generation Firewall

PIX 535. PIX 535 Product Overview CHAPTER

Smart Multivariable Transmitter (SMV 3000) Electronics Module Replacement Kit Instruction

EXN4000 Storage Expansion Unit Installation and Setup Instructions

Installing the IPS 4345 and IPS 4360

Juniper Networks G10 CMTS

for Hardware Installation: IG550 Integrated Gateway

Installing and Managing the Switch

Maintaining the ERX System

Installation and Maintenance

Switched Uplink Modules

SCv3000 and SCv3020 Storage System. Owner s Manual

Oracle <Insert Picture Here>

ACX4000 Universal Access Routers Quick Start

This section describes the software and hardware requirements for the module.

An ISO 9001 Company. BOP 1KW-MG FIRMWARE RETROFIT KIT

Installing the Cisco ASR 901 Mobile Wireless Router as a Satellite Shelf

FSM-510G Series Ethernet Management Switch Quick Start Guide

8~14-Port Managed Ethernet Switch

SSG 300M-series Hardware Installation and Configuration Guide

Transcription:

Part No. 530-005365-01 Revision 2 23 January 2002 CIP Description This document describes how to remove and replace the Connector Interface Panel (CIP) on a Juniper Networks M40e Internet router or M160 Internet router. For additional installation and configuration information, see the following documentation: M40e Internet Router Hardware Guide M160 Internet Router Hardware Installation Guide JUNOS Internet Software Operational Mode Command Reference JUNOS Internet software configuration guides Contents CIP Description...1 Routing Engine Interface Ports...3 BITS Input Ports...4 Alarm Relay Contacts...5 Tools and Parts Required...5 Replace the CIP...5 Remove the CIP...5 Install the CIP...7 Replace Cables and Wire Connecting to the CIP...8 Replace the Management Ethernet Cable...9 Replace the Console or Auxiliary Cable...10 Replace Alarm Relay Wire...11 Contact Juniper Networks...11 The Connector Interface Panel (CIP) is located at the left side of the FPC card cage. Figure 1 shows an M40e router, and the location of the CIP and other components is the same on teh M160 router. The CIP houses interface connectors and alarm relay contacts, shown in Figure 2 and described in the following sections: Routing Engine Interface Ports on page 3 BITS Input Ports on page 4 Alarm Relay Contacts on page 5 1

CIP Description 2 Figure 1: Front of Chassis 1900 R Craft interface Front support posts Center rack-mounting ear FPCs CIP ESD point Cable management system Air filter

CIP Description Figure 2: Connector Interface Panel HOST 0 ETHERNET ACT 0 YEL = 10M GRN = 100M CONSOLE AUXILLARY HOST 1 ETHERNET YEL = 10M GRN = 100M CONSOLE AUXILLARY Routing Engine Interface Ports ACT 1 BITS A LINK BITS B LINK RED ALARM NC C NO NC C NO YELLOW ALARM Routing Engine ports BITS input ports Alarm relay contacts 1204 On the upper half of the CIP are two sets of ports for connecting the Routing Engines to one or more external devices on which system operators can issue JUNOS command-line interface (CLI) commands to manage the router. The set of ports labeled HOST0 connects to the Routing Engine in the slot labeled RE0, and the set labeled HOST1 connects to the Routing Engine in the slot labeled RE1. The ports in each set are labeled as follows: ETHERNET Connects the Routing Engine through an Ethernet connection to a management LAN (or any other device that plugs into an Ethernet connection) for out-of-band management. The port uses an autosensing RJ-45 connector to support both 10- and 100-Mbps connections. Two small LEDs on the left edge of the port indicate the connection in use: the amber LED lights for a 10-Mbps connection and the green LED lights for a 100-Mbps connection. CONSOLE Connects the Routing Engine to a system console through an RS-232 (EIA-232) serial cable. AUXILIARY Connects the Routing Engine to a laptop, modem, or other auxiliary device through an RS-232 (EIA-232) serial cable. 3

CIP Description 4 Figure 3: Interface Ports for Routing Engine 0 BITS Input Ports Figure 3 shows the ports that connect to the Routing Engine installed in slot RE0. The arrangement of ports for the Routing Engine installed in slot RE1 is the same. Ethernet LEDs HOST 0 ETHERNET ACT YEL=10Mb GRN=100Mb CONSOLE AUXILIARY Ethernet port Console port Auxiliary port In the center of the CIP are two ports labeled BITS A and BITS B (see Figure 4). The router does not support BITS input, so these ports do not function. Figure 4: Alarm Relay Contacts and BITS Input Ports BITS A LINK BITS B LINK RED ALARM NC C NO NC C NO YELLOW ALARM 1173 BITS input ports Alarm relay contacts 1236

Tools and Parts Required Alarm Relay Contacts Tools and Parts Required Replace the CIP Remove the CIP At the bottom of the CIP are two relay contacts for connecting the router to external alarm-reporting devices, the upper labeled RED ALARM and the lower YELLOW ALARM (see Figure 4). A system condition that causes either the red or yellow alarm LED to light on the craft interface also activates the corresponding alarm relay contact. For instructions for attaching a device to the alarm relay contacts, see Replace Alarm Relay Wire on page 11. To replace the CIP, you need the following tools and parts: Phillips (+) screwdriver, numbers 1 and 2 ESD grounding wrist strap Electrostatic bag or antistatic mat 2.5 mm flat-blade ( ) screwdriver, for alarm relay terminal block Wire cutters, if attaching to an external alarm-reporting device The CIP is located to the left side of the FPC card cage, as shown in Figure 1. It weighs about 6.5 lb (3 kg). The CIP is field-replaceable, but you must power down the router before removing or installing it. To replace the CIP, perform the following procedures: Remove the CIP on page 5 Install the CIP on page 7 To remove the CIP, follow this procedure: 1. Place an electrostatic bag or antistatic mat on a flat, stable surface to receive the CIP. 2. Attach an ESD strap to your bare wrist and connect the strap to one of the ESD points on the chassis. 3. On the console or other management device connected to each Routing Engine, enter CLI operational mode and issue the following command to shut down the router software. For more information, see the JUNOS Internet Software Operational Mode Command Reference. user@host> request system halt Wait to continue until a message appears on the console confirming that the operating system has halted. 5

R Replace the CIP 6 Figure 5: Remove the CIP 4. Power down the router: On an M160 router or a DC-powered M40e router, flip both circuit breaker switches on the circuit breaker box to the OFF (O) position. On an AC-powered M40e router, flip the circuit breaker switch on both power supply faceplates to the OFF (O) position. 5. Disconnect any external devices connected to the CIP. For more information, see Replace Cables and Wire Connecting to the CIP on page 8. 6. Using a Phillips screwdriver, loosen and remove the screws at the top and bottom of the CIP faceplate. 7. Grasp the CIP and slide it out of the chassis (see Figure 5, which shows an M40e router). Place it in the electrostatic bag or on the antistatic mat prepared in Step 1. Be sure to slide the CIP straight out of the slot to avoid damaging the connecting pins on the front of the midplane. 1924

Replace the CIP Install the CIP To install the CIP, follow this procedure: 1. Verify that the router is powered down. 2. Carefully insert the rear of the CIP into the guides at the top and bottom of the CIP slot located to the left of the FPC card cage (see Figure 6, which shows an M40e router). The components on the CIP are on the left side of the board, unlike the components of an FPC, which are on the right side. Verify that the components are on the left before inserting the CIP. 3. Slide the CIP into the chassis until it contacts the midplane. Be sure to slide the CIP straight into the slot to avoid damaging the connecting pins on the front of the midplane. 4. Using a Phillips screwdriver, tighten the screws on the top and bottom of the CIP faceplate. 5. Reattach any external devices connected to the CIP. For instructions, see Replace Cables and Wire Connecting to the CIP on page 8. 6. Turn on the power to the management device that is connected to the Routing Engine through the CIP port labeled CONSOLE, AUXILIARY, or ETHERNET. 7. Flip one circuit breaker switch to the ON ( ) position (on the faceplate of one power supply on an AC-powered M40e router or on the circuit breaker box of an M160 router or DC-powered M40e router). Observe the LEDs on the power supply faceplate: On a properly functioning AC power supply, the green OUTPUT OK LED blinks rapidly for a short time, then lights steadily. On a properly functioning DC power supply, the green CB ON LED lights steadily, the blue OUTPUT OK LED blinks for a short time, then lights steadily, and the amber CB OFF LED does not light. 8. Flip the second circuit breaker switch and observe the LEDs on the second power supply faceplate. They should light as described in Step 7. 9. On the management device that was attached in Step 5, observe the trace of the startup sequence to confirm correct startup. If you can issue CLI commands over the connection when the startup is complete, the CIP is installed correctly. If you have connected to a Routing Engine through the port labeled ETHERNET, the flashing of the activity indicator LEDs (either the amber 10 Mbps or the green 100 Mbps LED) indicates that the CIP is connected properly and the Routing Engine is active. 7

R Replace Cables and Wire Connecting to the CIP 8 Figure 6: Install the CIP Replace Cables and Wire Connecting to the CIP Table 1 lists the specifications for the cables that connect to management ports and the wires that connect to the alarm relay contacts. Table 1: Routing Engine Interface Cable and Wire Specifications Cable Type Cable Specification Cable Supplied Maximum Length Routing Engine console or auxiliary interface Routing Engine Ethernet interface Alarm relay contacts RS-232 (EIA-232) serial Category 5 cable or equivalent suitable for 100BaseT operation 24-AWG to 12-AWG (0.20 to 3.33 mm 2 ) wire One 6-ft (1.83-m) length with DB-9/DB-9 connectors One 15-ft (4.92-m) length with RJ-45/RJ-45 connectors 6ft (1.83m) 1923 Router Receptacle DB-9 male 328 ft (100 m) RJ-45 autosensing No None

Replace Cables and Wire Connecting to the CIP To replace the cables that connect external management devices to the CIP, perform the procedures described in the following sections: Replace the Management Ethernet Cable on page 9 Replace the Console or Auxiliary Cable on page 10 Replace Alarm Relay Wire on page 11 Replace the Management Ethernet Cable Figure 7: Routing Engine Ethernet Cable Connector The cable that plugs into the port labeled ETHERNET on the CIP connects the Routing Engine to a network for out-of-band management. The port accepts a cable with RJ-45/RJ-45 connectors, which is provided with the router as described in Table 1. To replace the cable connecting to a management network, follow this procedure: 1. If a cable is already installed in the ETHERNET port, perform the following steps: a. Depress the tab on the connector (which is shown in Figure 7) and pull the connector straight out of the port. Figure 3 shows the ports that connect to the Routing Engine installed in slot RE0. The arrangement of ports for the Routing Engine in slot RE1 is the same. b. Repeat to disconnect the cable from the network device. 2. Plug one end of the replacement Ethernet cable into the ETHERNET port for the appropriate host module. See Figure 3. 3. Plug the other end of the cable into the network device. 1063 9

Replace Cables and Wire Connecting to the CIP 10 Replace the Console or Auxiliary Cable The cable that plugs into the port labeled CONSOLE on the CIP connects the Routing Engine to a system console, whereas the cable that plugs into the port labeled AUXILIARY connects the Routing Engine to a laptop, modem, or other auxiliary device. Both ports accept an RS-232 (EIA-232) serial cable with DB-9/DB-9 connectors. One such cable is provided with the router, as detailed in Table 1. If you want to connect a device to both ports, you must supply another cable. To replace the cable connecting to a management console or auxiliary device, follow this procedure: 1. If a cable is already installed in the CONSOLE or AUXILIARY port, perform the following steps: a. Turn off the power to the console or auxiliary device. b. Unscrew the screws securing the cable connector to the port, using a 2.5-mm flat-blade screwdriver if necessary. Figure 8 shows the cable connector. c. Pull the cable connector straight out of the port. d. Disconnect the cable from the console or auxiliary device. 2. Plug the female end of the replacement serial cable into the appropriate CONSOLE or AUXILIARY port. Figure 3 shows the ports that connect to the Routing Engine installed in slot RE0. The arrangement of ports for the Routing Engine in slot RE1 is the same. 3. Tighten the screws on the connector. 4. Power on the auxiliary or console device. Figure 8: Console and Auxiliary Serial Port Connector 1027

Contact Juniper Networks Replace Alarm Relay Wire Contact Juniper Networks The relay contacts on the CIP labeled RED ALARM and YELLOW ALARM connect to external alarm devices that report conditions that trigger a red or yellow alarm (see Figure 4). The terminal blocks that plug into the alarm relay contacts are supplied with the router. They accept wire of any gauge between 24-AWG and 12-AWG (0.20 and 3.33 mm 2 ), which is not provided. Use the gauge of wire appropriate for the external device that you are connecting to the terminal block. To replace the wires connecting to an alarm-reporting device, follow this procedure: 1. Prepare the required length of replacement wire with gauge between 24-AWG and 12-AWG (0.20 and 3.33 mm 2 ). 2. Select the appropriate relay contact the upper contact for a device that reports high priority (red) alarms, or the lower contact for the device that reports lower priority (yellow) alarms. 3. Disconnect the existing wire at the external device. 4. Using a 2.5 mm flat-blade screwdriver, loosen the small screws on the face of the terminal block and remove the block from the relay contact. 5. Using a 2.5 mm flat-blade screwdriver, loosen the small screws on the side of the terminal block. Remove existing wires from the slots in the front of the block and insert replacement wires. Tighten the screws to secure the wire. 6. Orient the terminal block according to the labels to the left of the chosen relay contact (NC means normally closed, C means common, and NO means normally open ). See Figure 4. 7. Plug the terminal block into the relay contact and use a 2.5 mm flat-blade screwdriver to tighten the screws on the face of the block. 8. Attach the other end of the replacement wire to the external device. For technical support, contact Juniper Networks at support@juniper.net. If you are reporting a software problem, please issue the following command from the CLI before contacting support: user@host> request support information save filename For documentation issues, contact Juniper Networks at tech-doc@juniper.net. To provide a core file to Juniper Networks for analysis, gzip the file, rename the file to include your company name, copy it to ftp.juniper.net:pub/incoming, and then send the filename, along with software version information (the output of the show version command) and the configuration, to support@juniper.net. 11

Contact Juniper Networks 12 Juniper Networks is a registered trademark of Juniper Networks, Inc. Internet Processor, Internet Processor II, JUNOS, JUNOScript, M5, M10, M20, M40, M40e, and M160 are trademarks of Juniper Networks, Inc. All other trademarks, service marks, registered trademarks, or registered service marks may be the property of their respective owners. All specifications are subject to change without notice. Copyright 2002, Juniper Networks, Inc. All rights reserved. Printed in USA.