Push Button Hour Timer Programmable between ¼ hour and 7½ hours with built in multi-way control

Similar documents
Push Button Switch for LED lighting with built in multi-way control

Rotary Dimmer with built in on / off switch and multi-way control

ehub Consolidation device for RAPIX input peripherals

Sapphire 24W 650mA-1000mA LED Driver Phase Dimmable

LEDsmart+ Slave Relay Device

One Channel and Two Channel DALI Relay Device

RAPIX Lighting Control System - ehub

Ethernet/DALI Interface 2 DALI Lines

Diginet Sitara. Simpler, Smarter Lighting Control for every Australian home. Products and Accessories. Avi-on ios/android App

Meso LED Driver stands for an extremely flexible LED Driver, designed for fast and easy configuration.

Phoebe LED Spectrum 10W RGB/Tuneable White downlight INSTALLATION AND APP INSTRUCTIONS

ARCTIC AIR DC OLED. Digital Control Operations Manual

Installation Instructions

OPERATE A SPREADSHEET APPLICATION ICAU1130B Excel 2010

Manual and application description 4 channel 0-10V dimmer V2.0

RF Wireless LED Remote Dimmer Controller Model: DIM Two Colors Dimmer / 6 Zones / 6 Options to save

CT1 Series 2. General Purpose Timer. Installation Manual 1 st Edition

Technical Manual. KNX/DALI ACTUATOR 1x8 channels Art /70100

FX2-CHILLER. Digital Control. Operations Manual

Installation Instructions

Installation Instructions

Manual and application description KNX/EIB LED driver V2.0

PULSE PIR Vers. IV. Light control. Operating Manual ENG

Technical Manual. DALI GATEWAY Art A

Use of the application program. Contents overview. Gamma instabus Application program description. November 2016

SMART DRIVER SDV-480. User Manual. Please read the instructions carefully before use

AQStation Dimmer. Manual. LAN/Wi-Fi-based-control. Typ: AQS Dimmer black Order-No.: Typ: AQS Dimmer white Order-No.:

TH100A User Manual 1 Updated April 30, 2018

RLD-7.2 Two Channel Light Dimmer. (P/N: P-RLD-72 Digital) User & Installation Manual

PULSE PIR Vers. IV with MFT

Programmable Logic Controllers. Second Edition

User Guide. 1.2Gbps Powerline Kit with Gigabit Port

Integriti User Manual. Elite / EliteX LCD Terminal Keypads

Ozone Toolset PC software User Manual

The Energy Savers. Universal dimmer switches, capacity enhancer and 1-10V controllers. Selection table for universal dimmer switches,

NX1700EIB02 (Supercedes NX1700EIA02) NetworX Series. NX-1700E Proximity Card Reader Installation and Startup

TanTime Systtem Timer Operation Instructions

SMM Series - LTE / 3G Modem SMM-400. Firmware Release Notes

2.4GHz Digital Wireless 7 LCD Surveillance Kit

LIGHTIFY App - User-Guide

Lamp Dimmer Module. Set-Up Guide

Tebis application software

USE BUSINESS TECHNOLOGY (WINDOWS 7 AND OFFICE 2010)

FX 2 Instruction Manual

MCR 808LX RELAY MANAGEMENT MODULE

Illuminate 25 Light Starter Kit What s included Light String Control Box Spare Fuses Safety Instructions Quick Start Guide

TS InteliSwitch Digital Time Switch 24VDC/VAC

Control Unit with Double Save/Recall, Cross-line and Zoom Display. Product No. OP

User Manual V K Camera with an Integrated 3-axis Gimbal

Universal Remote Controlled Lamp Dimmer User s Manual

ZONETOUCH DAMPER CONTROL SYSTEM Operation Manual

PWRguard PLUS Spring City Drive Waukesha, WI

HAIKU WALL CONTROL KIT

ph Meter & Controller Model: NANO-PCD1

EVERSAN. MODEL 9658 EVERSAN PERIOD INDOOR/OUTDOOR MULTI-FUNCTION SCOREBOARD. Instruction Manual

LCD MONITOR TOUCH PANEL DRIVER 2 OPERATION MANUAL. for Mac. Version 2.2

_A_en_LED63VG VOICE GUIDE KEYPAD LED63VG

L86 EM264. Front panel. electronics module

Installation Instructions

Micro Smart Dimmer 2E manual. In-Wall Electrical Installation Instructions:

Self-Adjusting Ultrasonic Wall Switch Sensor

APP User Guide. Model QES-200 QE-100 QS-100

Operating Your System

Package Contents... 1 Applied Models... 2 Specifications... 3 Reset Button... 4 Download & Install App... 5 Setup One Touch Setup

DX-Series LIU. Line Interface Unit. Quick Start Guide

DESSMANN - FINGERPRINT LOCK

Conquest Ethernet Controller Configuration Web Pages

DESSMANN - FINGERPRINT LOCK

Operating Your System

URC Light Sensor SEN-LITE for use with MRX units containing sensor ports

XC-42 OWNERS MANUAL COMPACT PORTABLE DIMMER. Revision /12/2007. Lightronics Inc. 509 Central Drive Virginia Beach, VA

USER MANUAL TEMPLATE ELECTRONIC DEADBOLT LOCK

Z-Wave Wireless Siren and Strobe

Aeotec Nano Dimmer user guide.

Brivis Touch. Owner s Manual

DC Pedals 5-Channel Bluetooth Looper

Omni. User Manual. Economic Self-Tune PID Temperature Controller. Omni 96. Omni 72 72X72. Omni ~ 265 V AC SUPPLY

Elation Architectural User Instructions. Elation Architectural. Rev. 4/ S. Eastern Ave. Los Angeles CA

LCD62. Keypad. User Manual

Serial Number Search Certificate

Advanced 4-Port DVI-I Secure KVM Switch

Micro-Master Touch Release Notes

Din Rail 8 Input / 8 Output Module

Installation Instructions

AnalogBridge Analog transmission system

1080p HD Car Event Recorder

UniStream Uni-I/O Modules

TH100A User Manual 1 Updated October 12, 2018

MSD Programmable Launch RPM Controller

USER MANUAL 1 OZONE TOOLSET PC SOFTWARE SW VERSION V Ozone ToolSet PC Software User Manual

HomePro ZDP100. Radio Frequency Controlled, 300W, 120 VAC, Plug-In Lamp Module, Release 2.0 ZDP100 PLUG-IN LAMP MODULE INSTALLATION

Upgrading MYOB BankLink Notes (desktop)

Scoreboard Operator s Instructions MPC Control

Quick Start Guide. ELPRO 105U-L Wireless I/O Receiver Unit. man_105u-l-r_quickstart_v1-8.doc

Advanced 4/8-Port DVI-D Matrix KVM

Professional Jukebox Software

VMB1DM Dimmer Module for Velbus system. Velbus manual VMB1DM edition 1 rev.2.0 1

MEGA DIAL PANEL Instructions

KEYPAD MODEL USER MANUAL

B19_Count_Monitor_ Amano McGann Build 19 Count Monitor Manual

Transcription:

Setup Functions Guide MMTH/PB Push Button Hour Timer Programmable between ¼ hour and 7½ hours with built in multi-way control DIGINET.NET.AU

Timer Setup Push Button Hour Timer The LEDsmart + push button timer has a number of useful functions which can easily be set up by entering setup mode and following the four easy steps. The TIMEOUT PERIOD should always be set up. The other settings are optional, depending on the application. To set the timeout period now, go to the next page. Timer Setup Functions Function See Part Setting the Timeout period Setting Maximum Brightness Setting Advanced Timer Features Setting Off State LED Feature Converting from hour to minute timer Setting MultiMate Mode Factory Defaults Reset A B C D E F G A: Entering Setup Mode If the timer has been powered up for LESS THAN 15 MINUTES see A1. If the timer has been powered up for MORE THAN 15 MINUTES see A2. Once in Setup Mode, options are selected by a series of clicks of the push button. Each click should be within 1 second of the previous click. 2

A1: Timer has been powered up via mains 240Vac for LESS THAN 15 MINUTES Press and hold the button for 10 seconds Note: Connected lights will dim up or down, this is normal Push Button Hour Timer The white LED Indicators will blink ON/OFF twice per second. This indicates that the timer is now in Setup Mode Note: If more than one LEDsmart + hour timer is connected in parallel, all these timers will now enter setup mode. The blink ON/OFF will also be seen on all other LEDsmart + hour timers connected in parallel The timer is ready for the settings to be adjusted as required. Go to the relevant setup function instructions A2: Timer has been powered up via mains 240Vac for MORE THAN 15 MINUTES Press and hold the button for 30 seconds Note: This resets the Setup Entry time back to 10 seconds (for the next 30 minutes) Note: Connected lights will dim up or down, this is normal The white LED Indicators will blink ON/OFF twice per second. This indicates that the timer is now in Setup Mode Note: If more than one LEDsmart + hour timer is connected in parallel, all these timers will now enter setup mode. The blink ON/OFF will also be seen on all other LEDsmart + hour timers connected in parallel The timer is ready for the settings to be adjusted as required. Go to the relevant setup function instructions 3

B: Setting the Timeout Interval The hour timer allows a timeout duration of ¼ hour to 7½ hours in increments of ¼ hour. Out of the box (factory defaults), the time out interval is set to ½ hour. To change the time out interval from the default ½ hour, follow the steps below. Enter into the timer Setup Mode - See PART A Click the push button 2 times The LED Indicator will blink 2 times To set the time out interval, push and hold the button and count the number of blinks. Each blink of the indicator adds ¼ hour to the timer When the number of blinks counted is equivalent the total timeout period required, release the button The time out interval is saved and setup will exit automatically Note During normal use the indicator will blink when the timer is turned on to indicate it is in time out mode Trying to select a time interval of 0 will result in setting ½ hour timeout The timeout period on Hour Timers connected in parallel need to be set individually. The same timeout is not automatically set across units 4

C: Setting Maximum Brightness The maximum brightness level provided by the timer can be set to suit customer requirements. Note that when lamps are near to full brightness, it is difficult to see changes in dimming level. Therefore, when setting up maximum brightness, it is recommended that the lamp is slowly dimmed up to a point where no further changes in brightness can be seen, and the maximum level set at this point. Enter into the timer Setup Mode - See PART A Click the push button 3 times The LED Indicator will blink 3 times Note: If more than one dimmer is connected to the same load, all dimmers connected to this load will now blink 3 times Push the button to achieve the required maximum brightness level Click once to save & exit Note: If more than one LEDsmart + device is connected in parallel, the minimum brightness levels only needs to be set in one device. The setting is automatically saved to all other devices connected in parallel 5

D: Setting Advanced Timer Mode The advanced timer mode provides an optional advanced warning to the user that the lights will shortly turn off automatically. When the advance timer is enabled, at time out the lights are dimmed to 50% over a 4 second period and are held at this 50% level for 5 minutes. After this 5 minutes, the lights are turned off automatically. Enter into the timer Setup Mode - See PART A Click the push button 4 times The LED Indicator will blink 4 times To enable the advanced timer mode Push and hold the button until the lamps(s) turn ON To disable the advanced timer mode Push and hold the button until the lamps(s) turn OFF (default) Click once to save & exit Note that during this 5 minute warning period:- The LED indicators will blink at a faster rate A tap of the push button will restore the load to 100% ON and the timer will restart A long press of the push button will turn the load OFF. 6

E: Setting Off State Indication When the timer is switched off, the white LED indicators in the timer can be set to glow or turn off. By Default, the white LED indicators are set to glow when the timer is turned off. To set the LED indicators to turn off when the timer is off, follow the steps below. Enter into the timer Setup Mode - See PART A Click the push button 5 times The LED Indicator will blink 5 times To set Indicator to glow on when timer is off Push the button until the lamp(s) turns ON To set Indicator to turn off when timer is off Push the button until the lamp(s) turns OFF Click once to save & exit 7

F: Convert Hour to Minute Timer If required, this hour timer can be converted to a standard LEDsmart minute timer, with a time out settable between 1 minute and 30 minutes, in 1 minute increments. To convert to a minute timer, follow the steps below. Enter into the timer Setup Mode - See PART A Click the push button 6 times The LED Indicator will blink 6 times To change operation to hour timer mode Push and hold the button until the lamps(s) turn ON (default) To change operation to minute timer mode (Set minute timer mode) Push and hold the button until the lamps(s) turn OFF Click once to save & exit 8

G: Setting Multimate Mode Enter into the timer Setup Mode - See PART A Click the push button 8 times LED will blink 8 times a. If the MultiMate function is currently Disabled, lamp(s) connected to the dimmer will now turn OFF b. If the MultiMate function is currently Enabled, lamps(s) connected to the dimmer will now turn ON To Enable MultiMate (Default) push-and-hold the button until the lamp(s) turns ON To Disable MultiMate push-and-hold the button until the lamp(s) turns OFF Click once to save & exit 9

H: Resetting to Factory Default Enter into the timer Setup Mode - See PART A Click the push button 10 times The timer will automatically exit Setup Mode once reset 10

Copyright This installation guide is copyright to Gerard Lighting. Except as permitted under relevant law, no part of this user and installation guide may be reproduced by any process without written permission of and acknowledgement to Gerard Lighting. Gerard Lighting Pty Ltd (Gerard Lighting) reserves the right to alter the specifications, designs or other features of any items and to discontinue any items at any time without notice and without liability. While every effort is made to ensure that all information in this user and installation guide is correct, no warranty of accuracy is given and Gerard Lighting shall not be liable for any error. Printed on recycled paper Product of Gerard Lighting Pty Ltd ABN 94 122 520 307 96-112 Gow Street Padstow NSW 2211 Contact General Enquiries: 1300 95 DALI (3254) or sales@diginet.net.au Technical Services: 1300 95 3244 or support@diginet.net.au Fax: 1300 95 3257 Diginet is a brand of the Gerard Lighting Group Version: Issue 1 July 2016 DIGINET.NET.AU