User Guide. Westermo Teleindustri AB MCW-211. Industrial Ethernet Media Converter.

Similar documents
User Guide. Westermo Teleindustri AB 2004 REV.A SDW Industrial Ethernet 5-port Switch.

User Guide Westermo Teleindustri AB SDW-500. Industrial Ethernet 5-port Switch.

800xA Networks. NE801 User Manual. Power and productivity for a better worldtm

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MANUEL D INSTALLATION RD-48 LV/HV. RS-422/485 Repeater Répéteur RS-422/485

User Guide. Westermo Teleindustri AB TD-29 DC. FSK-modem Multidrop 2-wire.

User Guide. Westermo Teleindustri AB RV-07B. 19 rack system PS-20 Power card.

ODW-641. Industrial Converter PROFIBUS DP to Fibre Optic Link. Point to Point applications. Fibre Optic Modem. User Guide

MCW-211-F1G-T1G. Industrial Ethernet Media Converter.

User Guide. Westermo Teleindustri AB DDW-100. Industrial Ethernet SHDSL Extender.

ODW-621 Fibre Optic Modem

User Guide. Westermo Teleindustri AB DDW-220. Wolverine series DDW-220. Industrial Ethernet SHDSL extender.

ODW-622 Fibre Optic Modem

Lynx. Industrial Ethernet 10-port Switch L110 / L210. User Guide

AD-01 M-BUS Adapter. Industrial adapter, M-bus, Repeater, Converter and zone controller.

User Guide. Westermo Teleindustri AB DDW-120. Industrial Ethernet SHDSL Extender.

Viper port Ethernet M12 switch. User Guide Westermo Teleindustri AB. X1 X5 X9 X6 X10 X7 X11 SRV 1 X2 X8 X12 DC X4

User Guide Westermo Teleindustri AB DDW-100. Industrial Ethernet SHDSL Extender.

User Guide. Westermo Teleindustri AB DDW-220 WOLVERINE SERIES DDW-220. Industrial Ethernet SHDSL extender.

User Guide Westermo Teleindustri AB. Lynx SERIES. Industrial Ethernet 8-port Switch.

User Guide. Westermo Teleindustri AB Lynx DSS. WeOS. Industrial Ethernet Device Server Switch.

User Guide Westermo Teleindustri AB. Lynx SERIES. Industrial Ethernet 8-port Switch.

User Guide. Westermo Teleindustri AB Lynx L110 / L210. WeOS. Industrial Ethernet 10-port Switch.

DDW-002-B1. EN Ethernet Broadband Bridge. User Guide Westermo Teleindustri AB. 10/100 BASE-TX LINK DC1 X1 X1 DC2

User Guide. Westermo Teleindustri AB RedFox. Ethernet switch and router approved for railway usage.

User Guide. Westermo Teleindustri AB Lynx L110 / L210. WeOS. Industrial Ethernet 10-port Switch.

User Guide. Westermo Teleindustri AB DDW-226 WOLVERINE SERIES. WeOS. Industrial Ethernet SHDSL extender.

Legacy Serial. Legacy Serial Redundant Ring Ethernet Extender DDW-222. High Speed Ethernet extension over copper. Configuration and diagnostics

User Guide. Westermo Teleindustri AB RedFox Industrial. WeOS. Industrial Routing Switch.

User Guide. Westermo Teleindustri AB Lynx DSS L105-S1/L205-S1. WeOS. Industrial Ethernet 5-port Device Server Switch.

User Guide. Westermo Teleindustri AB Lynx DSS L106-S2/L206-S2. WeOS. Industrial Ethernet 6-port Device Server Switch.

User Guide. Westermo Teleindustri AB RedFox Industrial. WeOS. Industrial Routing Switch.

User Guide. Westermo Teleindustri AB 2006 EDW Serial Adapter.

RedFox Industrial Series

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

User Guide Westermo Teleindustri AB EDW-100. Serial Adapter.

User Guide Westermo Teleindustri AB TDW-33. DIN-rail Tele V.90 modem.

FL MC 2000E (SM40) LC

RedFox Industrial Rack Series

User Guide. Westermo Teleindustri AB Lynx DSS L108 / L208-F2G-S2. WeOS. Industrial Ethernet 8-port Device Server Switch.

RuggedMC RMC RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. Ethernet Media Converter (Copper to Fiber) Universal Power Supply Options

Industry Line. Ethernet Solutions for Building Automation Systems and CCTV Surveillance Applications

RuggedMC RMC40 RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. 4-Port Ethernet Media and Speed Converter

SMM Series 3G and GSM Modems. Quick Start Guide. Document Number: Version: 1.2 (20 October, 2015)

User Guide. Westermo Teleindustri AB BRD-355. Industrial ADSL/VDSL Router.

Viper 20A Series. 20 port Ethernet M12 switches. User Guide REV. C. Westermo Teleindustri AB. X9 X15 X16 X17 X10 X11

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

MINI-PS AC/10-15DC/8

Redundancy Module QUINT-DIODE/40

Wolverine DDW DDW Industrial Ethernet Extender WeOS

TU531, TU532 Terminal Unit

AO523 Analog Input Module

IMC-101 Series Quick Installation Guide

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter

CompactBlock Guard I/O EtherNet/IP Safety Modules

Quick Start Guide Elinx ESW100 Series. 5 and 8 port Unmanaged Ethernet Switch

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

Viper-12A. 12 port Ethernet M12 switch. User Guide Westermo Teleindustri AB. ON USB X2 X3 RSTP FRNT CON V ON USB

ICF-1150 Series Quick Installation Guide

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

AI561 Analog Input Module

Industrial Routing Switch

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

D1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S

AO561 Analog Output Module

Series AMEPR60C-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

AX521 Analog Input/Output Module

Series AME5-CJZ 5 Watt AC-DC / DC-DC Converter

MRD-350. Industrial Mobile Broadband Router GSM / GPRS / EDGE / 3G / HSDPA / HSUPA / HSPA. User Guide

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

CM597 Ethernet Communication Module

TF501, TF521 Terminal Bases

MC 11 EB-2 Power supply cabinet with external bus, AC version

Series AMEL10-MJZ 10 Watt AC-DC / DC-DC Converter

AX522 Analog Input/Output Module

Quick Start Guide Elinx ESW200 Series. 5 and 8 port Unmanaged Ethernet Switch

Stride SE2 Series Unmanaged Industrial Ethernet Switches and Media Converters

Rugged MediaConverter

CliQ II DC-UPS Module 24V 40A / DRU-24V40ABN

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1A

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

ICF-1150 Series Quick Installation Guide

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

D5090S INSTRUCTION MANUAL. D A SIL 3 Relay Output Module for NE Load. DIN-Rail and Termination Board, Model D5090S

Industrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Series AME10-VZ 10 Watt AC-DC / DC-DC Converter

Redundancy unit CP-A RU

FLEX Ex Spring Clamp Terminal Base

Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches. Installation Guide. P/N (Rev G)

Chrome Class II DIN Rail Power Supply 24V 10W 1 Phase (NEC Class 2 & Household) / DRC-24V10W1HZ

1756 ControlLogix Chassis Specifications

Series AMER120-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1AZ

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

CliQ II Buffer Module 24V 20A / DRB-24V020AB

CliQ II Buffer Module 24V 20A / DRB-24V020AB

PI-EX-ME-2NAM/COC-24VDC

Transcription:

User Guide 6645-2204 MCW-211 S E R I E S Westermo Teleindustri AB Industrial Ethernet Media Converter www.westermo.com

Legal information The contents of this document are provided as is. Except as required by applicable law, no warranties of any kind, either express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, are made in relation to the accuracy and reliability or contents of this document. Westermo reserves the right to revise this document or withdraw it at any time without prior notice. Under no circumstances shall Westermo be responsible for any loss of data or income or any special, incidental, and consequential or indirect damages howsoever caused. More information about Westermo can be found at the following Internet address: http://www.westermo.com 2 6645-2204

Safety!!! Before installation: Read this manual completely and gather all information on the unit. Make sure that you understand it fully. Check that your application does not exceed the safe operating specifications for this unit. This unit should only be installed by qualified personnel. This unit should be built-in to an apparatus cabinet, or similar, where access is restricted to service personnel only. The power supply wiring must be sufficiently fused, and if necessary it must be possible to disconnect manually from the power supply. Ensure compliance to national installation regulations. This unit uses convection cooling.to avoid obstructing the air flow around the unit, follow the spacing recommendations (see Installation section). Before mounting, using or removing this unit: Prevent access to hazardous voltage by disconnecting the unit from power supply. Warning! Do not open connected unit. Hazardous voltage may occur within this unit when connected to power supply. Class 1 Laser Product Do not look directly into fibre optical fibre port or any connected fibre although this unit is designed to meet the Class 1 Laser regulations. Care recommendations Follow the care recommendations below to maintain full operation of unit and to fulfil the warranty obligations. This unit must not be operating with removed covers or lids. Do not attempt to disassemble the unit. There are no user serviceable parts inside. Do not drop, knock or shake the unit, rough handling above the specification may cause damage to internal circuit boards. Do not use harsh chemicals, cleaning solvents or strong detergents to clean the unit. Do not paint the unit. Paint can clog the unit and prevent proper operation. Do not expose the unit to any kind of liquids (rain, beverages, etc). The unit is not waterproof. Keep the unit within the specified humidity levels. Do not use or store the unit in dusty, dirty areas, connectors as well as other mechanical part may be damaged. If the unit is not working properly, contact the place of purchase, nearest Westermo distributor office or Westermo Tech support. Fibre connectors are supplied with plugs to avoid contamination inside the optical port. As long as no optical fibre is mounted on the connector, e.g. for storage, service or transportation, should the plug be applied. 6645-2204 3

General This unit is intended for use in Zone 2 hazardous location only. Marking ATEX Information (Applicable for MCW-211 Ex only) II 3 G Ex na IIC T4 Gc SPECIAL CDITI WARNING DO NOT SEPARATE WHEN ENERGIZED Indicate that this unit complies with relevant European standards that are harmonised with the 94/9/EC Directive (ATEX). II 3 G Ex na IIC T4 Gc SPECIAL CDITI Equipment group II. This unit can be installed in all places with an explosive gas atmosphere other than mines susceptible to firedamp Equipment category 3. A category is the classification according to the required level of protection. This unit ensures the requisite level of protection during normal operation and is intended for use in areas in which explosive atmosphere caused by gases, vapours, mists, or dust mixtures are unlikely to occure or, if they do occure, are likely to do so only infrequently and for a short periode only. Indicates protection concerning explosive atmospheres caused by gases, vapours or mists (G). Indicates that this unit is in conformity with relevant European Ex standard(s). Type of protection used. This unit is a non-sparking device "na" which is constructed to minimize the risk of occurence of arcs or sparks capable of creating an ignition hazard during conditions of normal operation. Gas group, a typical gas i hydrogen. Temperature class T4 (T4 = 135 C). This unit is classified in accordance with its maximum surface temperature (external and internal). Equipment protection level Gc (EPL Gc). Equipment for explosive gas atmospheres, having a "enhanced" level of protection, which is not a source of ignition in normal operation and which may have some additional protection to ensure that it remains inactive as an ignition source in the case of regular expected occurences. EPL Gc are analogous to the ATEX Categories (Category 3 G = EPL Gc). This unit has a special condition of use. The special conditon for safe use contains safety related information that is necesarry for the correct installation and safe use. 4 6645-2204

Ratings and safety control drawing Power (12 48) VDC; 200 ma Ambient temperature 25ºC Ta +70ºC Maximum surface temperature Temperatur class T4 (max 135 ºC ) Degree of protection IP21 Installation spacing Minimum 25 mm above / below and minimum 10 mm left / right Ethernet TX RJ-45 Position Direction*/ descripton 1 In/Out / TD+ 2 In/Out / TD 3 In/Out / RD+ 4 Not connected 5 Not connected 6 In/Out / RD 7 Not connected 8 Not connected Input/Output values U = ±1 V (4 µv/s) l = ±20 ma Data rate: 10/100 Mbit/s * Galvanically isolated via signal transformers and capacitively isolated to signal ground through 3 kv 470 pf capacitor. Ethernet FX SC, ST or LC Position Direction/ descripton Input/Output values Rx In / Receive port Max optical power = dbm Tx Out / Transmit port Data rate: 100 Mbit/s Power Position Direction/ descripton Input/Output values 1 In / COM U in = (10 60) VDC 2 In / +VA Max l in = 0.29 A @ 10 VDC 3 In / +VB MaxP In = 3.6 W The FX port is selectable between SC, -ST or -LC connection depending on variant of the model. 6645-2204 5

SPECIAL CDITI FOR SAFE USE Ambient temperature: This unit is designed for use in extreme ambient temperature conditions according to the following: 25ºC Ta +70ºC Installation in an apparatus cabinet: This unit requires installation in an Ex certified apparatus cabinet suitable for the area of use and providing a degree of protection of at least IP54. Resistance to impact: This unit requires installation in an apparatus cabinet where adequate resistance to impact is provided by the apparatus cabinet. See "Installation in an apparatus cabinet" above for requirements on the external apparatus cabinet. Resistance to light: This unit requires installation in an apparatus cabinet where it is protected from light (for example daylight or light from luminaires). See "Installation in an apparatus cabinet" above for requirements on the external apparatus cabinet. Secureness of plugs: When this unit is installed in an explosive atmospheres, all connectors must be mechanically secured to prevent loosening. Conductor temperature: When this unit is installed in locations with high ambient temperature, special precautions shall be taken upon the choice of external conductors and the temperature rating of the conductor(s). Directive 94/9/EC alongside with other directives: Directive 2004/108/EC (EMC) applies and to assure a safe performance of this unit under the scope of Directive 94/9/EC, refer to the electromagnetic immunity level specified under "Type tests and environmental conditions" in this manual. Standards and date of compliance EN 60079-0 and EN 60079-15 2011-04-27 6 6645-2204

Note. Fibre Optic Handling Fibre optic equipment needs special treatment. It is very sensitive to dust and dirt. If the fibre will be disconnected from the modem the protective hood on the transmitter/ receiver must be connected. The protective hood must be kept on during transportation. The fibre optic cable must also be handle the same way. If this recommendation not will be followed it can jeopardise the warranty. Cleaning of the optical connectors In the event of contamination, the optical connectors should be cleaned by the use of forced nitrogen and some kind of cleaning stick. Recommended cleaning fluids: Methyl-, ethyl-, isopropyl- or isobutyl-alcohol Hexane Naphtha Maintenance No maintenance is required, as long as the unit is used as intended within the specified conditions. Agency approvals and standards compliance Type EMC Approval / Compliance EN 61000-6-2, Immunity industrial environments EN 61000-6-4, Emission industrial environments Marine DNV Standard for Certification no. 2.4¹ Ex EN 60079-0 and EN 60079-15² Note ¹ Applicable only for 3645-0030, 3645-0040, 3645-0050 (MCW-211-SM-LC15, MCW-211-SM-LC40, MCW-211-MM-LC2) ² Applicable only for MCW-211Ex series 6645-2204 7

Declaration of Conformity Westermo Teleindustri AB Declaration of conformity The manufacturer Westermo Teleindustri AB SE-640 40 Stora Sundby, Sweden Herewith declares that the product(s) Type of product Model Art no Industrial Ethernet Media Converter MCW-211 series 3645-0001, -0010, -0020, -0030, -0040, -0050 MCW-211 EX series 3645-5001,-5010, -5020, -5030, -5040, -5050 is in conformity with the following EC directive(s). No Short name 2004/108/EC Electromagnetic Compatibility (EMC) 94/9/EC 1 Equipment Explosive Atmospheres (ATEX) References of standards applied for this EC declaration of conformity. No Title Issue EN 61000-6-2 Electromagnetic compatibility Immunity for industrial 2005 environments EN 61000-6-4 Electromagnetic compatibility Emission for industrial 2007 environments EN 60079-0 Explosive atmospheres 2009 Equipment General requirements EN 60079-15 Electrical apparatus for explosive gas atmospheres Construction, test and marking of type of protection n electrical apparatus 2005 The last two digits of the year in which the CE marking was affixed: 11 Pierre Öberg Technical Manager 27 April 2011 1 Applicable for MCW-211 EX series only. Org.nr/ Postadress/Postal address Tel. Telefax Postgiro Bankgiro Corp. identity number Registered office S-640 40 Stora Sundby 016-428000 016-428001 52 72 79-4 5671-5550 556361-2604 Eskilstuna Sweden Int+46 16428000 Int+46 16428001 8 6645-2204

Type tests and environmental conditions Electromagnetic Compatibility Phenomena Test Description Level ESD EN 61000-4-2 Enclosure contact ± 4 kv Enclosure air ± 8 kv RF field AM modulated IEC 61000-4-3 Enclosure 10 V/m 80% AM (1 khz), 80 2700 MHz Fast transient EN 61000-4-4 Signal ports ± 1 kv Power ports ± 2 kv Surge EN 61000-4-5 Signal ports balanced ± 2 kv line to earth, ± 1 kv line to line Power ports ± 2 kv line to earth, ± 2 kv line to line RF conducted EN 61000-4-6 Signal ports 10 V 80% AM (1 khz), 0.15 80 MHz Voltage dips and interruption Power ports 10 V 80% AM (1 khz), 0.15 80 MHz EN 61000-4-29 DC power ports 10 & 100 ms, interruption 10 ms, 30% reduction 10 ms, 60% reduction +20% above & 20% below rated voltage Radiated emission EN 55022 Enclosure Class A Conducted emission EN 55022 DC power ports Class A Dielectric strength EN 60950 Signal port to other isolated ports Environmental Power port to other isolated ports 1.5 kvrms 50 Hz 1 min 2 kvrms 50 Hz 1 min Temperature Operating 25 to +70ºC Maximum surface temperature Storage & Transport 135 C (temperature class T4) 40 to +70ºC Humidity Operating 5 to 95% relative humidity Storage & Transport 5 to 95% relative humidity Altitude Operating 2 000 m / 70 kpa Service life Operating 10 year Vibration IEC 60068-2-6 Operating 7.5 mm, 5 8 Hz 2 g, 8 500 Hz Shock IEC 60068-2-27 Operating 15 g, 11 ms Packaging Enclosure, MCW-211 UL 94 PC / ABS Flammability class V-1 Enclosure, MCW-211 Ex Cabelec 6141 Dimension W x H x D Weight 35 x 121 x 119 mm 0.25 kg Degree of protection IEC 529 Enclosure IP 21 Cooling Mounting Convection Horizontal on 35 mm DIN-rail 6645-2204 9

Interface specifications Power Rated voltage Operating voltage Rated current Rated frequency Inrush current I2t Startup current* Polarity Redundant power input Isolation to Connection 12 to 48 VDC 10 to 60 VDC 200 ma @ 12 VDC 100 ma @ 24 VDC 50 ma @ 48 VDC DC 0.03 A²s @ 12 VDC 0.75 A peak Reverse polarity protected Yes Ethernet TX Ethernet FX Detachable screw terminal Connector size 0.2 2.5 mm² (AWG 24 12) Shielded cable * Direction relative this unit Not required Ethernet TX Electrical specification Data rate Duplex Transmission range Isolation to Connection Ethernet FX Optical specification Data rate Duplex Connection IEEE std 802.3. 2000 Edition 10 Mbit/s or 100 Mbit/s, manual or auto Full or half, manual or auto 100 m Power RJ-45 IEEE std 802.3. 2000 Edition 100 Mbit/s Full or half SC, ST or LC 10 6645-2204

Location of interface ports and LED s LED Indicators (for details see page 13) DIP switches are accessible under the lid Ethernet TX RJ-45 Position Direction* Description 1 In/Out TD+ 2 In/Out TD 3 In/Out RD 4 5 6 In/Out RD 7 8 * Direction relative this unit Ethernet FX SC, ST or LC Position Direction* Description Product marking Rx In Receive port Rx Tx Out Transmit port * Direction relative this unit Power Position Direction* Description Tx Product marking 1 Common COM 2 In + Voltage A +VA 3 In + Voltage B +VB * Direction relative this unit 6645-2204 11

Fibre optic power budget Model Transmitted wavelength Min. output power, transmitter Max. output power, transmitter Input sensitivity, receiver Min. power budget Max. power budget Recommended fibre cable and core / cladding diameter MCW-211-MM xx2 MCW-211-SM SC15 MCW-211-SM LC15 MCW-211-SM LC40 1310 nm 1310 nm 1310 nm 1310 nm 19 dbm 15 dbm 15 dbm 5 dbm 12 dbm 8 dbm 8 dbm 0 dbm 31 dbm 34 dbm 31 dbm 34 dbm 12 dbm 19 dbm 16 dbm 29 dbm 19 dbm 26 dbm 23 dbm 34 dbm Multimode 50/125, 62.5/125 Singlemode 9/125, 10/125 Singlemode 9/125, 10/125 Singlemode 9/125, 10/125 Fibre type Normal attenuation @ 1310 nm multimode Normal attenuation @ 1310 nm singlemode 50/125 3.0 dbm/km 62,5/125 3.5 dbm/km 9/125 0.5 dbm/km 10/125 0.5 dbm/km Attenuation in connectors / splices Type Connector Fusion splice Mechanical splice Normal attenuation 0.2 0.4 dbm 0.1 dbm 0.2 dbm 12 6645-2204

LED indicators LED indicators are available on the front panel and on the RJ-45 TX connector. LED Status Description PWR Internal power, initialising OK Slow flash Fast flash Initialisation progressing Initialisation error LINK TX OFF No Ethernet link TX Flash Good Ethernet link TX Ethernet data is transmitted or received on TX interface LINK FX OFF No Ethernet link FX Flash Good Ethernet link FX Ethernet data is transmitted or received on FX interface FX DPX OFF Half dupex FX interface Full duplex FX interface LFF OFF Link fault forward is not active Link fault forward is active and has shutdown an interface LED Status Description SPD OFF 10 Mbit/s TX interface 100 Mbit/s TX interface DPX OFF Half duplex TX interface Full duplex TX interface SPD TX DPX 6645-2204 13

! Installation Mounting / Removal Before mounting or removing the unit: Prevent damage to internal electronics from electrostatic discharges (ESD) by discharging your body to a grounding point (e.g. use of wrist strap). Prevent access to hazardous voltages by disconnecting the unit from AC/DC mains supply and all other electrical connections. Mounting This unit should be mounted on 35 mm DIN-rail which is horizontally mounted on a wall or cabinet backplate. This unit uses convection cooling. To avoid obstructing the airflow around the unit, use the following spacing rules. Recommended spacing 25 mm (1.0 inch) above/below and 10 mm (0.4 inches) left/right the unit. Snap on mounting, see figure 10 mm * (0.4 inches) 25 mm CLICK! * Spacing (left/right) recommended for full operating temperature range 25 mm Removal Press down the black support at the back of the unit, see figure. 14 6645-2204

Configuration DIP switches are accessible under the lid on top of the unit. DIP switches are used to configure the unit.! DIP-switch settings Before DIP-switch settings: Prevent damage to internal electronics from electrostatic discharges (ESD) by discharging your body to a grounding point (e.g. use of wrist strap). NOTE DIP-switch alterations are only effective after a power on. To be observe when the DIP-switches will be configured Speed and duplex setting only valid when auto-negotiation is disabled. If auto-negotiation and auto MDI/MDI-X disabled the TX ports supports MDI-X configuration. 6645-2204 15

TX Port settings Flow control setting Auto-negotiation and auto MDI / MDI-X disabled TX port Flow control disabled Auto-negotiation and auto MDI / MDI-X enabled TX port Flow control enabled 10 Mbit/s speed selected TX port Link fault forward settings 100 Mbit/s speed selected TX port TX FX Link fault forward disabled Half duplex selected TX port TX FX Link fault forward enabled Full duplex selected TX port FX TX Link fault forward disabled FX Port settings FX TX Link fault forward enabled Half duplex selected FX port Factory settings Full duplex selected FX port 16 6645-2204

Westermo Teleindustri AB SE-640 40 Stora Sundby, Sweden Phone +46 16 42 80 00 Fax +46 16 42 80 01 E-mail: info@westermo.com Westermo Web site: www.westermo.com Sales Units Sweden Westermo Data Communications AB Svalgången 1 SE-724 81 Västerås Phone: +46 (0)21 548 08 00 Fax: +46 (0)21 35 18 50 E-Mail: info.sverige@westermo.se United Kingdom Westermo Data Communications Ltd Talisman Business Centre Duncan Road Park Gate, Southampton SO31 7GA Phone: +44(0)1489 580 585 Fax.:+44(0)1489 580586 E-Mail: sales@westermo.co.uk Germany Westermo Data Communications GmbH Goethestraße 67, 68753 Waghäusel Tel.: +49(0)7254-95400-0 Fax.:+49(0)7254-95400-9 E-Mail: info@westermo.de France Westermo Data Communications S.A.R.L. 9 Chemin de Chilly 91160 CHAMPLAN Tél : +33 1 69 10 21 00 Fax : +33 1 69 10 21 01 E-mail : infos@westermo.fr Singapore Westermo Data Communications Pte Ltd 2 Soon Wing Road #08-05 Soon Wing Industrial Building Singapore 347893 Phone +65 6743 9801 Fax +65 6745 0670 E-Mail: sales@westermo.com.sg North America Westermo Data Communications 939 N. Plum Grove Road, Suite F Schaumburg Chicago Phone: +1 847 619 6068 Fax: +1 847 619 66 74 E-mail: info@westermo.com Taiwan Westermo Data Communications Co F2, No. 188, Pao-Chiao Rd. Shing-Tien City Taipei 23145 Phone:+886 2 8911 1710 E-mail: info@westermo.com Westermo Teleindustri AB have distributors in several countries, contact us for further information. REV.A 6645-2204 2011.04 Westermo Teleindustri AB, Sweden A Beijer Electronics Group Company