Operating voltage Maximum

Similar documents
ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2TAZ710xx1R2161

Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

ABB i-bus KNX Switch Actuator, x-fold, 10 A, MDRC SA/S x , 2CDG11015xR0011

ABB i-bus KNX DALI Light Controller, 8-fold, MDRC DLR/S M, 2CDG110101R0011

ABB i-bus KNX Switch Actuator, Current Detection, x-fold, 16/20 A, C-Load, MDRC SA/S x , 2CDG1101xxR0011

ABB i-bus KNX Fan Coil Actuator, PWM, MDRC FCA/S , 2CDG110195R0011

ABB i-bus KNX Blower/Fan Coil-Actuator LFA/S 1.1, LFA/S 2.1. Product Manual. Intelligent Installation Systems ABB

ABB i-bus EIB / KNX Blower/Fan Coil-Aktuator LFA/S 1.1, LFA/S 2.1. Product Manual. Intelligent Installation Systems ABB

ABB i-bus KNX Fan Coil Actuators FCA/S Product Manual

ABB i-bus KNX Fan Coil Actuators FCA/S Product Manual

ABB i-bus KNX HCC/S Heating/cooling circuit controller

ABB i-bus KNX BCI/S Boiler/Chiller Interface

ABB i-bus KNX Blower Actuator FCL/S x Product Manual

ABB i-bus KNX Analogue Input, 4-fold, MDRC AE/S , 2CDG110190R0011

ABB i-bus KNX Room Master Basic RM/S 1.1 Product Manual

ABB i-bus KNX Room Master RM/S 3.1 Product Manual

ABB i-bus KNX Binary Inputs BE/S Product Manual

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

ABB i-bus KNX Analogue Actuator, 4-fold, MDRC, 0-10 V, 0-20 ma AA/S 4.1.2, 2CDG110202R0011

ABB i-bus KNX Weather Unit, 1-fold, MDRC WZ/S , 2CDG110184R0011

ABB i-bus KNX Room Master Premium RM/S 2.1 Product Manual

ABB i-bus KNX Room Master Basic RM/S 1.1 Product Manual

Control unit for lux control, MDRC Type: SL/S 50.1, GH Q R0001

Switch Actuator, 4-fold, 20 A, MDRC AT/S , GH Q R0111

The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal.

Product and functional description

ABB i-bus KNX Fan Coil Actuator FCA/S 1.1M Product Manual

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Datasheet RCUXXYY EAE KNX Room Control Unit RCUXXYY DT R1.0. General Description. EAE Technology Page 1/10

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX

ABB i-bus KNX Logic Controller ABA/S 1.2.1, 2CDG110192R0011

Product and functional description

1 Safety instructions. 2 Device components. 3 Function. Control unit, 1-10 V 3-gang. Order-No. : Operating instructions

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm

Product and functional description

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

1 Safety instructions. 2 Device components. 3 Function. Control unit 1-10 V, 3-gang. Art.-No.: 2193 REG. Operationsmanual

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

ABB i-bus KNX Blind/Roller Shutter Actuator JRA/S Product Manual

Product and functional description

ABB i-bus EIB. Shutter Actuator, 2-fold, 6 A, 230 VAC, MDRC JA/S 2.6.1, GH Q R0111

Switch Actuator, 4-fold, 16 A, MDRC AT/S , GH Q R0111

ABB i-bus KNX Blind/Roller Shutter Actuators JRA/S Product Manual

Product and functional description

Product and functional description

Siemens Spares. RL 513D23 Switching actuator (relay), 3 x 6A. Technical Product Information

Line Coupler, MDRC LK/S 3.1, GH Q R0001

Product Manual V ABB i-bus EIB / KNX DALI-Gateway DG/S 1.1. Intelligent Installation Systems ABB

ABB i-bus KNX IP Router, MDRC IPR/S 3.1.1, 2CDG110175R0011

Extension module for lighting control

ABB i-bus. KNX JRA/S Blind/Roller Shutter Actuator with Binary Inputs Product Manual

Push Button Interface UP 220D31

PRODUCT MANUAL. ABB i-bus KNX SV/S KNX-Power Supplies

Line Coupler, MDRC LK/S 2.1, GH Q R0001

ABB i-bus KNX DALI Gateway Emergency Lighting DGN/S Product Manual

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012

ABB i-bus KNX AC/S Application Controller

11 Series - Light Dependent Relay A. Features pole 17.5 mm wide. 1 pole zero hysteresis 4 position selector

High-performance switching actuators

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

Operating instructions. Standstill monitor A / / 2011

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

SITOP in the SIMATIC Design

K-BUS R. Dimming Actuators. User manual-ver. 4 KA/D KA/D KA/D KA/D 04.T1.1 ADTV-04/16.1 KA/D 04.L1.1 ADLD-04/

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

QUINT-PS/ 1AC/24DC/ 5

Electrical devices may only be mounted and connected by electrically skilled persons.

DALI Professional Controller-4. Control unit Operating instructions

Linienkoppler S KNX. Line coupler S KNX. Line coupler S KNX Status: March 16 (Subject to change) Page 1 of 29

LL1x50-E-DA. 1x50 W Dimmable DALI LED driver. 50 W V 0 / 50 Hz 60 Hz. Functional description. Mains characteristics

1 pole 17.5 mm wide 2,000 2, ,000 1,000 halogen W DC / / / / 30

COMPACT LED DRIVERS. PrimeLine DALI dimmable & Selectable Current (Dip Switch) PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH)

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Power supply. Interface technology in modular housing DIN rail devices, IM series. Features

QUINT-PS AC/24DC/10

PI-EX-ME-2NAM/COC-24VDC

COMPACT LED CONVERTERS 48 V

EAE KNX Switch Actuator

pole 17.5 mm wide. electronic ballast W

ISOMETER isopv with coupling device AGH-PV

ABB i-bus KNX Application Unit Time ABZ/S 2.1 Product Manual

UNIVERSAL DIMMER DIM02SA/500U

ABB i-bus EIB / KNX Shutter Actuator with Manual Operation, 4-fold, SMI, MDRC JA/S 4.SMI.1M. Product Manual. Intelligent Installation Systems ABB

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions

DC561, digital input/output module,

Power supply CP-D 12/2.1 Primary switch mode power supply

UNIVERSAL DIMMER DIM02SA/500U

UNIVERSAL DIMMER DIM04SA/500U

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

TRIO-DIODE/12-24DC/2X10/1X20

QUINT-PS/ 1AC/24DC/20/CO

Power supply CP-C 24/5.0

Operating instructions. Switching amplifier DN0210 DN / / 2015

LINEAR LED DRIVERS. PrimeLine DALI dimmable. PrimeLine DALI DIMMABLE , , , , ,

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

KNX/EIB Flush-mounted universal dimming actuator 210 W. 1 Safety instructions. 2 Device components. Order-No. : Operating instructions

PI-EX-ME-2NAM/COC-120VAC

Transcription:

, 2CDG 110 0x R0011 2CDC 071 023 F000 The ABB i-bus Light Controllers, (x = 2 or 4) are KNX modular installation devices in ProM Design for installation in the distribution board on 35 mm mounting rails. The connection to the ABB i-bus is implemented via a bus connection terminal on the device shoulders. The LR/S can control dimmable electronic ballast or transformers with 1-10 V interface via 2 or 4 outputs depending on the device. For every output a floating switching contact (16 A) for direct switch on and off of the ballasts is available. The switching relays are particularly suitable for switching fluorescent lamp loads (AX) to DIN EN 60 669. Manual switch ON and OFF of the individual outputs is possible in manual control independently of the bus or auxiliary voltages. The operating element on the switching relay directly indicates the switch status. A separate Light Sensor LF/U 2.1 can be separately connected on the Light Controller for each output. The Light Sensor measures brightness in closed rooms. The Light Controller undertakes constant light control for each output (control circuit) with this brightness value. It is possible to use several Light Sensors for a single output. The Light Controller and the connected Light Sensor are supplied with power via the KNX and do not require an additional power supply. Technical data Supply Operating voltage 21...30 V DC, made available by the bus Current consumption KNX Maximum.5 ma 10 ma Power consumption via KNX Max. 250 mw Outputs control circuit LR/S type Number of control outputs 1-10 V (passive) 2 4 Max. current per control output 100 ma 100 ma Max. number of ballast (2 ma/ballast) 1) 50 50 Max. cable length, with max. load (100 ma) 70 m with conductor cross-section 0. mm 2 100 m with conductor cross-section 1.5 mm 2 Sensor input LF/U 2.1 2) Brightness detection Outputs load circuit rated values Number of inputs Max. cable length per sensor Lighting control operating range Optimum installation height LR/S type Number of load outputs (floating) U n rated voltage I n rated current Leakage loss per device at max. load 2 with LR/S 2.16.1 or 4 with LR/S 4.16. 100 m, Ø 0. mm, P-YCYM or J-Y(ST)Y cable (SELV), e.g. shielded KNX bus cable Optimised for 500 Lux. 200...1200 Lux for rooms with average furnishing level (reflection 0.5) max. 60 Lux in a very brightly furnished room (reflection 0.7) max. 3000 Lux in a very darkly furnished room (reflection 0.2) The Lux values are measured values on the work surface (reference surface) 3) 2-3 m 2 4 250/440 V AC (50/60 Hz) 16 A-AC1 or 10 AX 2.6 W 5.2 W Page 1 of 6 2CDC 507 07 D0201

, 2CDG 110 0x R0011 Load circuit (relay) switching currents AC1 operation (cos ϕ = 0.) DIN EN 60 947-4-1 Fluorescent lighting load AX to DIN EN 60 669-1 AC3 operation (cos ϕ = 0.6) DIN EN 60 947-4-1 Minimum switching performance DC current switching capacity (ohmic load) 16 A / 230 V 10 AX/250 V (140 μf) 4) A / 230 V 100 ma/12 V 100 ma/24 V 10 A/24 V = Lamp loads See lamp load table Load circuit (relay) Mechanical endurance > 3 x 10 6 service life Electrical endurance to DIN IEC 60 947-4-1 AC1 (240 V/cosϕ = 0.) > 10 5 AC5a (240 V/cosϕ = 0.45) > 3 x 10 4 Load circuit (relay) switching times 5) LR/S type Max. relay position change per output and minute 60 30 if all relays are switched simultaneously. The position changes should be distributed over a minute. Max. relay position change per output and minute 120 120 if only one relay is switched Connections: ABB i-bus KNX bus connection terminal 0. mm Ø, single core Connections: Screw terminal with slotted screw 0.2...2.5 mm 2 stranded - Control circuit 0.2...4 mm 2 single core - Light sensor LF/U 2.1 sleeves without/with plastic TWIN sleeves Tightening torque Connections: load circuit Screw terminal with universal head (PZ 1) 0.25...2.5/0.25 4 mm 2 0.5...2.5 mm 2 Max. 0.6 Nm 0.2...4 mm 2 stranded, 2 x (0.2-2.5 mm 2 ) 0.2...6 mm 2 single core, 2 x (0.2-4 mm 2 ) sleeves without/with plastic TWIN sleeves Tightening torque 0.25...2.5/0.25 4 mm 2 0.5...2.5 mm 2 Max. 0. Nm Operating and display elements Red LED and KNX button For assignment of the physical address Switch position display Relay operator Enclosure IP 20 to DIN EN 60 529 Safety class II to DIN EN 61 140/IEC 536 Isolation category Overvoltage category III to DIN EN 60 664-1 Pollution degree 2 to DIN EN 60 664-1 KNX safety extra low voltage SELV 24 V DC Temperature range Operation -5 C...+45 C Storage -25 C...+55 C Transport -25 C...+70 C Environmental conditions Humidity Max. 93 %, moisture condensation should be excluded Design Modular installation device (MDRC) ProM LR/S type Dimensions (H x W x D) 90 x W x 64.5 Width W in mm 72 10 Mounting width (modules at 1 mm) 4 6 Weight in kg 0.200 0.330 Installation On 35 mm mounting rail DIN EN 60 715 Mounting position as required Housing, colour Plastic housing, grey Approvals KNX to EN 50 090-2-2 Certification CE mark in accordance with the EMC guideline and low voltage guideline Page 2 of 6 2CDC 507 07 D0201

, 2CDG 110 0x R0011 Lamp loads, switching powers for lamp circuit Lamps Incandescent lamp load 2300 W Fluorescent lamps T5 / T Uncorrected Parallel compensated DUO circuit 2300 W 1500 W 1500 W Low-volt halogen lamps Dulux lamp 1) The control current of 1-10 V devices determine the number of connectable ballast devices. Typical devices are between 0.4 4 ma. 2) Note: LF/U 1.1 not suitable Inductive transformer Electronic transformer Halogen lamp 230 V Uncorrected Parallel compensated Mercury-vapour lamp Uncorrected Parallel compensated Switching capacity (switching contact) 6) Max. peak inrush-current I p (150 μs) Max. peak inrush-current I p (250 μs) Max. peak inrush-current I p (600 μs) Number of electronic ballast (T5/T, single element) 1) 1 W (ABB EVG 1 x 5 CF) 24 W (ABB EVG-T5 1 x 24 CY) 36 W (ABB EVG 1 x 36 CF) 5 W (ABB EVG 1 x 5 CF) 0 W (Helvar EL 1 x 0 SC) 1200 W 1500 W 2300 W 1100 W 1100 W 2000 W 2000 W 400 A 320 A 200 A 3) Rooms are lit up differently by the incidental daylight and the artificial lighting of the lamps, and not all surfaces in the rooms (walls, floor, furniture, etc.) reflect the light which falls on them in the same manner. Accordingly, even though there is an exactly calibrated constant lighting control in daily operation, deviations to the set target value may occur. These deviations may be up to +/- 100lx should the current ambient conditions in the room, and accordingly the reflection properties of the surfaces (paper, persons, reorganized or new furniture), differ significantly from the original ambient conditions at the time of calibration. Deviations may also occur if the Light Sensor is influenced by direct or reflected light falling on it which is not influenced or only slightly influenced by the surfaces in the detection range of the Light Sensor. 4) The maximum inrush-current peak (see table Lamp loads ) may not be exceeded 5) The specifications only apply after the device has been connected to the bus voltage for min. 30 seconds. Typical delay of the relay is approx. 20 ms. 6) For multiple element lamps or other types, the number of electronic ballast devices must be determined using the peak inrush current of the electronic ballast. See the example: Planning and application 23 23 14 11 10 Caution The connection of a 230 V mains voltage supply to one of the 1-10 V outputs or sensor inputs leads to the destruction of the 1-10 V end stage or the corresponding sensor input. Control and load ends are electrically isolated from the KNX. The individual relays are potential free (floating). When connecting the control line it is important to consider that the control outputs each feature a common reference ground with one another. Several electronic ballast with a 1-10 V interface can be controlled by one output of the Light Controller. The number of dimmable ballast per output is limited both by the switching and the control powers of the Light Controller. For calculation example see: Planning and application. Page 3 of 6 2CDC 507 07 D0201

, 2CDG 110 0x R0011 User programs Number of Communication objects Max. number of group addresses Control Dim 2f 1-10V/1 62 254 255 Control Dim 4f 1-10V/1 11 254 255 Max. number of associations Note For a detailed description of the application program see Light controller and light sensor LF/U 2.1 product manual. It is available free-ofcharge at www.abb.de/knx. The programming requires EIB Software Tool ETS2 V1.3 or higher. If ETS3 is used a.vd3 or higher type file must be imported. The application program for the ETS2/ETS3 can be found at ABB/EIB Lighting Devices/Illumination and Light Sensors/Control Dim xf 1-10V/1, (x = 2 or 4, number of outputs). The devices do not support the closing function of a project or the KNX devices in the ETS. If you inhibit access to all devices of the project with a BA password (ETS2) or a BCU code (ETS3), it has no effect on this device. Data can still be read and programmed. Circuit diagram LR/S 2.16.1 LR/S 4.16.1 2CDC 072 172 F0007 2CDC 072 173 F0007 1 Label carrier 2 KNX programming button 3 Red KNX programming LED 4 KNX connection terminal 5 Switch position display and ON/OFF manual actuation 6 Load circuit, for each 2 screw terminals 7 Control circuits (1 10 V) for each 2 screw terminals Light Sensor inputs, for each 2 screw terminals 9 Light sensor LF/U 2.1 Caution All-pole disconnection must be observed in order to avoid dangerous touch voltages which originate from feedback from differing phase conductors. Important An open 1-10 V control line produces the maximum ballast brightness. A short circuited control line generates the minimum dimming value. The minimum dimming value is also set if the control cable polarity is reversed. In all three cases dimming of the lighting is not possible. Page 4 of 6 2CDC 507 07 D0201

, 2CDG 110 0x R0011 Note An open Light Sensor cable (max. cable resistance) means the same as a dark room for the Light Controller. The 1-10 V output is controlled with maximum brightness during control. The same behaviour is also exhibited with a short circuit and if the sensor cable polarity is reversed. The sensor value can be read via the object Sensor value (No. 32, 57, 2 or 107) of the corresponding output. This value corresponds with the measured value on the sensor input, the Light Sensor detects the light luminance within its detection range. The value does not comply with the lighting intensity in Lux measured with a Lux meter underneath the Light Sensor. In all three fault scenarios (open circuit, short circuit and incorrect polarity) the value read via the object Sensor value is equal to 0. This value corresponds with the value of absolute darkness. Dimension drawing 2CDC 072 19 F0007 B LR/S 2.16.1 LR/S 4.16.1 72 mm 4 space units 10 mm 6 space units Page 5 of 6 2CDC 507 07 D0201

, 2CDG 110 0x R0011 Notes Page 6 of 6 2CDC 507 07 D0201