USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power

Similar documents
Powerware 3105 UPS User s manual

Powerware 3105 UPS User s manual

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System

POWERWALKER. Uninterruptible Power Supply. Line Interactive VI 1000/1400/2000. Thank you for purchasing PowerWalker UPS.

Model: VA/230W UPS Backup System

U P S USER S MANUAL IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. Uninterruptible Power System. Line Interactive (Network) UPS

Installation manual Digital Energy USB / RS232 / Relay Interface Card for use with GE Digital Energy VH Series UPS VA

OFFICE UPS MULTI-DEVICE PROTECTION UPS 500S/600S/750S

PowerMust Office Uninterruptible Power System

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

User Manual Back-UPS BE650MC

Installation and Operation Back-UPS Pro BR700G-TW

Back-UPS RS APC Back-UPS RS 800VA 120V Black

Back-UPS RS 550 Installation & Operation

User Manual Back-UPS Pro BN 1100/1350/1375/1400/1500 M2 BN 1100/1350/1500 M2-CA

Installation and Operation Back-UPS Pro 900

User s Manual. Professional Rack Mount LCD XL Series PR1000ELCDRTXL2U/PR1500ELCDRTXL2U/ PR2200ELCDRTXL2U K

Installation and Operation Back-UPS Pro 900

List of contents. 7-2 CE (ENC EN55022) declaration of conformity CE (LVD EN60950) declaration of conformity. 15 發行章

SA-150, SA-300 Series Pure Sine Wave Inverter User s Manual

EATON 5S 850/1200/1600

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

OFFICE UPS MULTI-DEVICE PROTECTION UPS 500S/600S/750S USER S MANUAL

True Sinewave Power Inverter 1000W & 2000W 230V , Owner s Manual

User s Manual Legend SB425 K

1. IMPORTANT SAFETY INSTRUCTIONS WARNING (SAVE THESE INSTRUCTIONS): This manual contains important instructions that should be followed during install

Installation and Operation Manual Back-UPS BR900G-RS

Network Camera. Quick Guide DC-B1203X. Powered by

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Broadband Automatic Disconnect Switch. User Manual

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

LVN5200A-R2, rev. 1, Hardware Installation Guide

user s manual Battery case model #: IPB3500S Battery Case Charger for iphone 6

Nature Power Inverters. Modified Sinewave 1000w/1500w True Sinewave 1000w/2000w. Owner s Manual

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

OPERATING INSTRUCTIONS UPS

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

Owner s Instruction Manual

Lightspeed Advanced Reporting Bottle Rocket Hardware Installation Guide

The power behind competitiveness. Delta UPS - Amplon Family. N Series, Single Phase 1/ 2/ 3 kva. User Manual.

Wise HP33 THREE PHASE HIGH PRECISION AVR SURVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

USER S MANUAL PFC SINEWAVE SERIES OR1000PFCRT2U/OR1500PFCRT2U/ OR2200PFCRT2U

POWER AVAILABILITY 2U POD USER MANUAL. Power Output Distribution 120 Volt

Modified Sinewave Series. Power Inverter 1000/1500 MW 1210, MW1215. True Sinewave Power Inverter 1000/2000 SW 1210, SW 1220.

Pulsar EXtreme 2000/3000 VA

Table of contents. 1. Introduction

INSTALLATION AND USER MANUAL Green Point T

User s Manual Legend SB500R UPS K

Technical Data Sheets Uninterruptible Power Supply LP11 Series UPS kva

POWER AVAILABILITY 2U POD USER MANUAL. Power Output Distribution 230 Volt

PowerNet RM SERIES 1500VA & 2200VA Line-interactive UPS USER MANUAL

EPS Power Supply

C300R 1-3 kva. Rack/Tower VA. Installation/Manual. Service and support T: +44 (0)

VS Series 120V 600VA 300W Line-Interactive Desktop UPS, Tower, 6 Outlets

1000VA/1500VA/2000VA/3000VA

FT-20 Fire Training Fog Machine User Manual English

E8431 First Edition Model: T00CP

Table of Contents. Automatic Transfer Switch. User Manual ATS-16A/20A/30A/32A

Liebert MicroPOD 230V

USER MANUAL Line Interactive UPS

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

3190 Series Touch Screen POS Workstation

1 Channel Strobe Controller ORDERCODE 40226

User manual. ONLINE YUNTO series Models Germany Italy Switzerland. ONLINE UPS-Systems S.r.l. Via Ferruccio Gilera 110 I Arcore (MB)

powerware 5105 User s Guide VA

P OCKET POWER 9000 T. Powerful Universal Portable Charger PLEASE READ BEFORE OPERATING THIS EQUIPMENT

Network Camera. Quick Guide DC-D1223WX. Powered by

4170 POS System Installation Guide

Smart-UPS APC Smart-UPS 1500VA USB & Serial 120V

ALPHA Automated Transfer Switch Operating Manual. Rev 1.21 The original of this document is drawn up in English language

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

LEGA ENERGY ELECTRONIC RELAY VOLTAGE STABILIZER VA USER MANUAL

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

POCKET MULTIMETER Model No: MM18

Installation and user manual English Français Deutsch Italiano Español Nederlands Pulsar Series

Smart-UPS APC Smart-UPS 750VA USB & Serial RM 1U 120V

PS8 - II. Professional Power Sequencer. User s Manual

P OCKET POWER 6000 T. Powerful Universal Portable Charger PLEASE READ BEFORE OPERATING THIS EQUIPMENT

Smart-UPS APC Smart-UPS 2200VA USB & Serial 120V

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

DOT MATRIX PRINTER SP6000 SERIES

DRP16 Series. User Guide. DVR Surge Protector & UPS. DITEK Corporation One DITEK Center 1720 Starkey Road Largo, FL

Evolution 650/650 Rack 1U 850/850 Rack 1U 1150/1150 Rack 1U 1550/1550 Rack 1U Installation and user manual Pulsar Series

Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A

FengMi Wemax One Laser Projection TV

Owner s Manual. Models: ECO650LCD, ECO850LCD. Not suitable for mobile applications

FT-20 Fire Training Fog Machine User Manual English

User Manual. AN A GPON Optical Network Unit. Version: A. Code: MN Date: December 2011

Liebert PSA5. Installer/User Guide

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

D-Pack 6 Classic ORDERCODE 50315

User s Manual PR5000LCDRTXL5U

Liebert PST5. Installer/User Guide

TECHCONNECT TC2-HDMI14 OWNERS MANUAL

Version /11/2015. User Manual. PowerLine AV HD Gigabit Passthrough Kit DHP-P601AV

Transcription:

Critical Power USER MANUAL Uninterruptible Power Supply Line-interactive VCL Series UPS 400 600 800 1000 1500 VA GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91 / 850 52 52 www.gecriticalpower.com g imagination at work

GB User manual Uninterruptible Power Supply Line-interactive VCL Series UPS 400-600 - 800 1000-1500 VA Please read these instructions carefully before installation and start-up of the VCL Series UPS. Keep this manual in a safe place for future reference. Model: VCL Series 400 1500 VA Issued by: Product Document Department Riazzino - CH Date of issue: 11.02.2014 File name: Revision: 1.3 Identification No.: Up-dating Revision Concerns Date 1.0 release initial manual 21.12.2012 1.1 dimensions and weight 22.04.2013 1.2 start-up, filtering and runtimes 01.07.2013 1.3 branding, certification 11.02.2014 modifications reserved Page 2/10

Table of contents Page 1 IMPORTANT SAFETY INSTRUCTIONS... 4 1.1 SAVE THESE INSTRUCTIONS... 4 1.2 SAFETY RULES... 4 1.3 WARRANTY... 5 1.4 STORAGE... 5 2 INSTALLATION & OPERATION... 5 2.1 INTRODUCTION... 5 2.2 INSTALLATION... 6 2.3 OPERATION... 6 2.4 BATTERY REPLACEMENT PROCEDURE... 8 2.5 RECYCLING THE UPS AT THE END OF SERVICE LIFE... 9 3 TROUBLESHOOTING... 9 4 SPECIFICATIONS...10 modifications reserved Page 3/10

1 IMPORTANT SAFETY INSTRUCTIONS 1.1 SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during installation and maintenance of the UPS. It also gives all necessary information about the correct use of the UPS. Before attempting to install and start up the UPS, carefully read this manual. Keep this manual next to the unit for future references. Full understanding of and compliance with the safety instructions and warnings contained in this manual are the ONLY CONDITIONS to avoid any dangerous situation during installation, operation and maintenance work, and to preserve the maximum reliability of the UPS system GE refuses any responsibility in case of non-observance, unauthorized alterations or improper use of the delivered UPS. The instructions in this manual are for UPS models VCL400, VCL600, VCL800, VCL1000 and VCL1500. You can find the model name at the rear panel of your UPS. While every care has been taken to ensure the completeness and accuracy of this manual, GE accepts no responsibility or liability for any loss or damage resulting from the use of the information contained in this document. 1.2 SAFETY RULES CAUTION! RISK OF ELECTRIC SHOCK The UPS contains batteries. The appliance outlets may be electrically live, even when the UPS is disconnected from the mains. The UPS contains potentially hazardous voltages. Do not open the unit, there are no user serviceable parts inside. All maintenance and service work should be performed by qualified service personnel. The UPS is intended to be used in normal domestic and office situations. The branch circuit supply has to be protected with a 16 A building fuse. The UPS must be powered from a single phase grounded wall outlet. This wall outlet must be easily accessible and close to the UPS. Do not use extension cords. Place cables in such a way that no one can step on or trip over them. Avoid locations that are excessively humid, near water, near heat sources or in direct sunlight. The ambient temperature should not exceed 40C. Optimal battery lifetime is obtained if the ambient temperature does not exceed 30C. It is important that ventilation air can move freely around and through the unit. Do not block the air vents. Do not plug appliances such as electric heaters, toasters and vacuum cleaners into the UPS. The UPS output can be used only for electronic loads such as computers and telecommunications equipment. Always disconnect the input power cord from the wall outlet before replacing the battery. Never dispose of batteries in a fire: they may explode. Never disassemble or reassemble batteries; their contents (electrolyte) may be extremely toxic. Never short the battery terminals. Shorting may cause the battery to burn. When working with batteries remove watches, rings or other metal objects and only use insulated tools. Proper disposal of batteries is required: refer to your local codes for disposal requirements. modifications reserved Page 4/10

1.3 WARRANTY GE, operating through its authorized agents, warrants that the standard products will be free of defects in materials and workmanship for a period as per contract specifications. NOTE This warranty does not cover failures of the product which result from incorrect installation, misuse, alterations by persons other than authorized agents, or abnormal operating conditions. 1.4 STORAGE Store the UPS in a dry location with the batteries in a fully charged state. Storage temperature must be within -15 +55C. If the unit is stored for a period exceeding 3 months, optimal battery lifetime is obtained if the storage temperature does not exceed 25 C. If the unit is stored for an extended period of time, the batteries must be recharged every 2 months. CAUTION In case of storage, pay attention to: 2 INSTALLATION & OPERATION 2.1 INTRODUCTION The GE (General Electric) VCL Series UPS, a line-interactive uninterruptible power supply, has been designed to protect your sensitive electronic equipment such as computers and telecommunications equipment from virtually all forms of power interference, including complete power failures. When the mains supply is present and the UPS is switched on, the UPS is charging the battery and providing power to the connected equipment from the AC line directly. In case of a mains failure the reliable battery can provide the stable power to complete your work, save the data and safely shut down your system. Inspect the UPS for damage after unpacking. If any damage is present please immediately notify the carrier and place of purchase. WARNING! In case of recognizable damage: DO NOT connect any voltage to the unit DO NOT put the unit into operation. Condensation may occur if the UPS system is moved directly from a cold to a warm environment. The UPS system must be absolutely dry before being installed. Please allow an acclimatization time of at least two hours prior to installation. Save the original packing material. No liability can be accepted for any transport damage when the equipment is shipped in non-original packaging. modifications reserved Page 5/10

2.2 INSTALLATION 1. Connect the mains cord of the UPS to a working, grounded AC wall socket outlet. The unit will start automatically. 2. For best results, allow the UPS to recharge the batteries during a period of approx. 8 hours. It is acceptable to use the UPS without first charging the battery, but the runtime may be reduced. 3. Plug your computer and monitor into the Battery backup & surge protection outlets. These outlets will provide emergency battery backup power during a mains power failure as well as surge protection from surges and spikes. CAUTION: Do NOT plug LASER PRINTERS into any of the Battery backup & surge protection or surge protection outlets. CAUTION: Do NOT plug an ACCESSORY SURGE strip into any of the Battery backup & surge protection outlets. 4. Plug your peripheral equipment (printer, scanner, fax, speaker, etc.) into the Surge protection outlets. NOTE: These outlets will NOT provide battery backup power during a mains power failure. 5. When the On mains LED illuminates, switch on the connected equipment. 2.3 OPERATION 1. ON/OFF Button Press and hold the ON/OFF button for one beep, then release it to turn on (or turn off) the UPS. The UPS will charge the battery as long as the mains power is present. NOTE: When you turn on the UPS it will perform a self-test during which the alarm will sound intermittently. 2. LED On mains/ on battery (green) This green LED illuminates when the UPS is on and receiving the normal mains power. It indicates that the connected equipment is receiving power and the battery is charging. The LED will blink and the alarm beeps every 10 seconds when the UPS operates on battery. modifications reserved Page 6/10

3. LED Overload/ replace battery/ UPS fault (red) This red LED will blink and the alarm sounds 2 beeps every second when the load connected to the Battery backup & surge protection outlets exceeds the nominal capacity of the UPS. The UPS will automatically shut down after beeping for ten seconds. The LED will blink and the alarm sounds 3 beeps every 30 seconds when the UPS detects that the battery needs to be replaced soon. Allow the UPS to recharge the battery for at least 4 hours. If the LED lights again after 4 hours of charging, the battery needs to be replaced to ensure full protection for your equipment. Contact your dealer. When the UPS detects a hardware fault, the red LED will illuminate, the alarm will sound continuously and the UPS will shut down. In some instances the fault condition may be cleared by switching the UPS off and then on again. 4. Input socket AC mains supply to the UPS. 5. Outlets Surge protection The outlets provide full time protection from surges and spikes. Peripheral equipment that does not require power during a mains power failure, e.g. printers, scanners, fax machines, or speakers can be connected to these outlets. 6. Outlets Battery backup & surge protection The outlets not only provide full time surge protection but also provide emergency battery backup power during a mains power failure such as a blackout or brownout. 7. Phone/FAX protection The RJ11 jacks can provide protection against surges and spikes on your phone line. 8. RJ11 USB communication port The provided GE monitoring and shutdown software can be automatically configured to save your files and shut down your computer in the event of a prolonged power outage. Refer to the manual that came with the software. 9. Circuit breaker In case of a severe overload the circuit breaker may trip. The button will come out, the UPS is disconnected from the mains and output power is lost. In this situation reduce the load connected to the Battery backup & surge protection and/or Surge protection outlets of the UPS. Subsequently reset the circuit breaker by pushing the button back in. LED display & buzzer alarm list Green LED Red LED Alarm UPS Status Indication On X X On mains (bypass / AVR mode) On Blinking 3 beeps every 30 seconds Replace battery On Blinking 2 beeps every second Over load X On Continuous buzzer Fault / output short circuit Blinking X 1 beep every 10 seconds On battery Blinking Blinking 2 beeps every 5 seconds Battery low X On Continuous buzzer Battery over voltage modifications reserved Page 7/10

2.4 BATTERY REPLACEMENT PROCEDURE (Qualified service personnel only) 1. Turn off the equipment that is connected to the output sockets of the UPS. 2. Turn off the UPS. 3. Unplug the UPS power cord from the AC wall outlet. 4. Unplug the equipment from the output sockets of the UPS. 5. Remove the 2 screws at the bottom side of the front panel (fig. 1.) 6. Slide the panel downward, off the UPS (fig. 2). 7. Disconnect the red and black DC wires from the battery terminals (fig. 3). NOTE : DO NOT short the battery wires. 8. Replace the battery. 9. Connect the battery wires to the battery terminals. NOTE: a small spark might occur, this is normal. 10. Reinstall the front panel (fig. 4). 11. Fasten the two screws (fig. 5). General guidelines 1. When replacing the batteries, use only the same type and size battery. 2. Never short the battery terminals. Shorting may cause the battery to burn. When working with batteries remove watches, rings or other metal objects and only use insulated tools. 3. Avoid charging in a sealed container. 4. Never dispose of batteries in a fire: they may explode. 5. Never disassemble or reassemble batteries; their contents (electrolyte) may be extremely toxic. If exposed to electrolyte, wash immediately with plenty of water, if eye contact occurs flush with water and contact a physician. modifications reserved Page 8/10

2.5 RECYCLING THE UPS AT THE END OF SERVICE LIFE The batteries contain lead, which is a harmful substance for the environment. Proper disposal or recycling of the batteries is required. Refer to your local codes for disposal requirements! PB GE, in compliance with environment protection recommends that the UPS equipment, at the end of its service life, must be recycled conforming to the local applicable regulations. 3 TROUBLESHOOTING Whenever a malfunction occurs, first check external factors (e.g. connections, temperature, humidity or load) to determine whether the problem is caused by the unit itself or by its environment. Subsequently check the thermal circuit breaker: it may be tripped. If so: reset it and be sure that the UPS is not overloaded. The following chart is a simple troubleshooting checklist only. If the suggested solution does not succeed, or if the information is insufficient to solve the problem, please contact your dealer or consult www.gecriticalpower.com. PROBLEM POSSIBLE CAUSE SOLUTION UPS will not switch on Continuous buzzer, red LED blinks UPS does not provide the expected runtime Connected equipment loses power while connected to the UPS UPS line cord not connected and/or UPS is not switched on UPS circuit breaker tripped Overload on the Battery backup & surge protection outlets The battery is not fully charged Aging battery Overload Battery depleted Equipment is connected to the wrong outlet The UPS may be faulty Plug the line cord of the UPS into an AC wall outlet and switch on the UPS. If the wall outlet is dead, make sure the building branch circuit breaker is not accidentally turned off or contact a qualified electrician Reduce the load, reset the circuit breaker Turn off the UPS and reduce the load connected to the Battery backup & surge protection outlets Remove the load and charge the battery for at least 8 hours. Replace battery See above The UPS will turn off when the battery has been depleted during the mains failure. Allow the UPS to recharge the battery Plug the equipment that should continue to operate during a mains failure into the Battery backup & surge protection outlets Contact your dealer or consult www.gecriticalpower.com modifications reserved Page 9/10

4 SPECIFICATIONS Model : VCL400 VCL600 VCL800 VCL1000 VCL1500 Rating VA/W : 400/250 600/360 800/480 1000/600 1500/900 AC input voltage window : 170 ~ 280Vac Frequency : 50 / 60 Hz auto sensing Battery type : 12V, sealed lead acid, maintenance free Number x capacity of battery : 1x4.5Ah 1x7Ah 1x9Ah 2x7Ah 2x9Ah Battery recharge time : 8 hours typical Runtime in minutes at typical load (60%) : 5 6 6 8 6 Internet / phone / fax protection : RJ-11 (One pair), 2C; 114 joules; clamping rate 330V Communication port : USB (RJ11) Ambient temperature : 0 C ~ 40 C (+32 F ~ 104 F) Maximum relative humidity : 95% (non-condensing) Storage temperature : -15 C ~55 C (+5 F ~ 131 F) Net weight (kg) : 4.0 4.6 5.6 8.4 10.3 Dimensions (hxwxd, mm) : 220x112x222 220x112x330 This document shall not be copied nor reproduced without the permission of GE. Due to technical improvements, some of the information contained in this manual may be changed without notice. General Electric Consumer & Industrial SA. All rights reserved; reproduction without permission prohibited. The content of this manual may be subject to change without prior notice; no liability can be accepted for any error or omission. The illustrations and plans describing the equipment are intended as general reference only and are not necessarily complete in every detail. modifications reserved Page 10/10