RF adapter plugs, dimming

Similar documents
ERF910. RF Repeater. Synco living

Heating Circuit Controller

Heating Circuit Controller

Power supply module, bus connection module

RMZ792. Bus Operator Unit. Building Technologies HVAC Products. Synco 700

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Electromotoric actuators

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

Web interface BACnet/IP

Extension module for lighting control

Electrical Actuators

Communication module to connect M-bus devices to POL6xx.xxx controllers.

Resistance measuring module

USB-KNX Interface OCI702. USB-KNX interface with cables and service bag

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

Electrical actuators

Electromotoric actuators

OCI Service tool. As of ACS790 V9.00. Service case with software and service interface

Electrical Actuators

Electrical Actuators

s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

Extension module Integration of existing PTM I/O modules in Desigo Used with PXC50...D, PXC100...D or PXC200...D

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use

Room Temperature Controller

Electromotoric actuators

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

RMZ790. Operator Unit. Building Technologies. Synco 700

Island bus expansion module

Room automation station

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Immersion Temperature Sensors

AEW Pulse Adapter. Building Technologies

Room unit with PPS2 interface

AEW36.2. Pulse Adapter. Building Technologies. Siemeca AMR

SEH62.1. Digital Time Switch

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

Room unit with PPS2 interface

Room unit with PPS2 interface

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Mobile Data Collector

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Network node WTT56.. A6V _en--_c Building Technologies

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Semi flush-mounted room temperature controllers with LCD

Status display unit with P-bus connection

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

RDF301 RDF CE1N3171en 02 Jun 2010 Building Technologies

OZW V3.0. Web server. For Synco TM, Synco TM living

Product and functional description

Fast running actuators for air dampers

Electromotoric actuators

Product and functional description

SAX.. ACVATIX Electromotive actuators for valves. with a 20 mm stroke

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

Room unit with PPS2 interface

Air damper actuators

PXM20-E. Operator unit BACnet auf Ethernet/IP DESIGO PX

Rotary actuators for ball valves

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

Room Temperature Controller

QUICKSTART Smart EnOcean Gateway DC-GW/EO-IP

Communication over Modbus protocol Connection with multiple controllers Application upgrade by using an SD 1) card or a USB stick

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

Universal Controller

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

OCI Service Tool. Siemens Building Technologies HVAC Products. ACS plant operating software and OCI700 service interface

TXM1.8RB. TX-I/O Blinds module

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

VAV modular controller

Handheld Tool for VAV compact and modular controllers

Rotary version, three-position control

Operating Manual -ENGLISH- Page 1 KWG-ISO

Room thermostat with KNX communications For VAV heating and cooling systems

Central control unit

VAV compact controller KNX / PL-Link

Electromotive actuators for combi valves

Cube LAN Gateway. Operating manual BC-LGW-O-TW

Technical Documentation

Semi Flush-mount Room Temperature Controllers with LCD

Interface converter for VAV compact controllers

BACnet/IP Web Interface

Network nodes with gateway

Switching module for AC V and up to three load stages, with manual switching

QVE3000.0xx QVE3100.0xx. Flow sensor. for liquids in DN10 25 pipes

Room Temperature Controllers

Product and functional description

Datasheet liniled Dim 4-DALI-PRO

NI PXI-1042 Series Power Supply Shuttle

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Semi flush-mounted room temperature controllers with LCD

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

Micro calibration bath Models CTB , CTB

APT20. User Manual.

Features: Example of use

7-day room temperature controller

USB 3.0 TO SATA ADAPTER HARD DRIVE ADAPTER WITH OTB FUNCTION

Digital input modules

Mid-span 802.3af PoE Injector. Installation Guide KPOE-100

Transcription:

s 2 719 Function LED Function button Synco living RF adapter plugs, dimming KRF961.. Radio-controlled adapter plugs for switching and dimming electrical lights up to 300 W RF communication based on KNX standard (868 MHz, bidirectional) Mains-powered AC 230 V Use For integration into the Siemens Synco living system For remote control of dimmable lights connected to power outlets Operation via KNX-RF or manually CE1N2719en 05.11.2008 Building Technologies

Equipment combinations The RF adapter plug KRF961 is for use with the Siemens Synco living system. For detailed information about equipment combinations, refer to the Data Sheet on the QAX910 central apartment unit (CE1N2707en). Ordering When ordering, please give quantity, product name and type reference. Scope of delivery The KRF961 is supplied complete with Mounting Instructions. Type summary The RF adapter plug KRF961 is available in the following versions: Type of mains plug Product No. Type of power outlet F KRF961-F 2718Z01 E KRF961-E 2718Z02 L KRF961-L 2718Z03 J KRF961-J 2718Z04 Product documentation The Operating and Commissioning Instructions for the KRF961 are part of the product documentation on the QAX910 central apartment unit. 2 / 6

Functions Main function Binding Supply state Power break Child-proofing The KRF961 is used for remote control of electrical lights connected to power outlets. Each KRF961 can be dimmed via the central apartment unit, either individually or in groups. The KRF961 signs on at the central apartment unit, thereby integrating itself into the wireless system. The binding process is triggered by pressing the function button. The process is indicated by the function LED. The KRF961 can be reset to its supply state by pressing the function button. If reset, the adapter plug must be reintegrated into the system. After a power break (e.g. after disconnecting the KRF961), the connected lamp is dead. The KRF961 features mechanical child-proofing. This means that live parts inside the adapter plug cannot be touched by introducing objects. Operating and indicating elements Function LED Function button Functions of the operating and indicating elements: Function LED Dimming action Binding action Function button Binding Switching (no dimming) Resetting to the supply state 3 / 6

Engineering and operating notes Mounting location Mounting Commissioning Protection against overheating and overloads Maintenance Disposal The KRF961 must be plugged into a power outlet The permissible environmental conditions must be observed Do not modify the device for outdoor use The KRF961 must not be exposed to drip water For Planning and Mounting Instructions on wireless devices of the Siemens Synco living system, refer to Data Sheet CE1N2708en The KRF961 is suited for use with all types of commercially available power outlets (note type of outlet!). For commissioning, the KRF961 must be plugged into a power outlet at the location where it is used. The device is protected against overheating and overloads. In the case of overheating or overload, the device s output is reduced. Remedy: Check the connected load and ensure compliance with the technical data specified below. The KRF961 is maintenance-free. In terms of disposal at the end of the product s service life, the KRF961 is regarded as electronic scrap conforming to the European Directive 2002/96/EC (WEEE) and must not be disposed of together with domestic waste. Disposal must take place through appropriate channels. Local and currently valid legislation must be observed. Warranty Warranty with regard to application-related data is valid only when the KRF961 is used in connection with the Siemens Synco living system. When used with products of other manufacture, correct operation must be ensured by the user. In that case, Siemens does not provide any service or warranty. 4 / 6

Technical data Power supply Operating voltage AC 230 V (±15%) Frequency 50 Hz Power consumption (excl. external load) Max. 1.65 VA Radio control Electrical connections Types of load Frequency Range Protocol Power outlet Plug Incandescent lamps (AC 230 V) Halogen lamps (AC 230 V) Low-voltage halogen lamps via ferromagnetic transformer (DC 12 V / 24 V) Low-voltage halogen lamps via electrical transformer (DC 12 V / 24 V) 868 MHz, bidirectional Typically 30 m in buildings KNX RF-compatible For connecting appliances with plug type F, E, L, or J For connecting the KRF961 to a power outlet type F, E, L, or J 20 300 W 20 300 W 20 200 VA 20 200 VA Standards Environmental compatibility conformity as per EMC directive - Immunity, Emissions Low-voltage directive - Electrical safety RTTE (Radio & Telecom. Equipment) - RF communication Environmental Product Declaration CM1E2719en contains data on environment-friendly product design and assessment (RoHS conformity, substances used, packaging, environmental benefits and disposal) 2004/108/EC - EN 60669-2-1, EN 50428 2006/95/EC - EN 60669-1, EN 60669-2-1, EN 50428 1999/5/EC - EN 300 220-2, EN 301 489-1 - EN 301 489-3 ISO 14001 (environment) ISO 9001 (quality) SN 36350 (environment-compatible products) RL 2002/95/EG (RoHS) Degree of protection Dimensions Weight Material of housing Housing color Housing KRF961 complete with enclosure IP30 Refer to Dimensions 0.172 kg Plastic PC+ABS RAL 9010 Environmental conditions Operating temperature 0 45 C Storage temperature -20 70 C 5 / 6

Dimensions Dimensions in mm 2719M01 6 / 6 2008 Siemens Switzerland Ltd Subject to change