GTX TM SUPER YACHT UNIT SUBSTATION. General Specifications

Similar documents
Commodore SS Model CD General Specifications

SECTION SWITCHBOARDS

SPECIAL SPECIFICATION 1864 Pole Mounted Cabinet

PDI Modular Compact Remote Power Panel

IIM Warwick Court. Williamsburg VA REV 5

Electrical Components and Equipment for General Use Self Inspection Checklist

Maximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches

POWER DISTRIBUTION

SECTION (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

alid portable power cart epcc panel ccts EPCC-60 40" 60A, 120/208V 3PH 24 EPCC " 100A, 120/208V 3PH 24

AIR COOLED MODULAR RECTIFIER

FDS / FDS-R / FDS-PS

SECTION DISTRIBUTION SWITCHBOARDS

SECTION 16450: NON-AUTOMATIC TRANSFER SWITCH / QUICK CONNECT GENERATOR SWITCHBOARD <S> <OM>

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

Elastimold Molded Vacuum Recloser - MVR

SECTION WIRING DEVICES PART 1 - GENERAL. A. Drawings and Division 1 Specification Sections, apply to this Section.

ASCO 920 Remote Control (RC) Switches

SECTION PANELBOARDS

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

SECTION WIRING DEVICES

920 Remote Control (RC) Switches

The General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified in this Section.

1. Distribution panelboards. 2. Lighting and appliance branch-circuit panelboards. 3. Load centers. 4. Electronic-grade panelboards.

C-POWER AC AUTOMATIC CONTROL

SPECIAL SPECIFICATION 6274 Microwave Vehicle Detection System

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE

ASCO SERIES 300 Manual Transfer Switch Solutions

Application Techniques CENTERLINE 2100 Motor Control Centers

(1986; Rev. 1989) Molded Case Circuit Breakers and Molded Case Switches. (1985; Rev. 1988) Enclosures for Electrical Equipment (1000 Volts Maximum)

Brasch Washdown Unit Heaters

SECTION PANELBOARDS. A. NECA (National Electrical Contractors Association) -Standard of Installation

Instrument Current Transformers

Overview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel.

TOT Series Manual. North American and International Models - without optional faceplate. Receptacle Panel of International Models, CE model shown

Installation Manual. APEX Series. Silicon and MOV Panel Protection. APEX Series

INSTALLATION INSTRUCTIONS

TOT Series Manual. North American CE and UK Models. CE Models. UK Models. North American Models

Target Interface / Construction Compliance Inspection Checklist

GENERAL UL th EDITION DESIGN-BUILD SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.

SECTION DISCONNECT SWITCHES

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

Innovative POWER Solutions

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment.

File E Project 12SC February 9, 2013 REPORT. Component - Protectors, Low-voltage Solid-state Overcurrent

CITY OF BOISE SPECIFICATIONS FOR LIGHT EMITTING DIODE (LED) STREET LIGHTING Effective 1 Feb, 2018

MICHIGAN DEPARTMENT OF TRANSPORTATION

These specifications describe requirements for a power distribution unit (PDU) distributing power to sensitive loads.

S&C IntelliRupter PulseCloser Fault Interrupter Overhead Source-Transfer Application

PanelView Plus/VersaView CE Terminals and Display Modules

Arca LED 5YEAR LED WARRANTY. Order Code: Pole Order Code: Customer: Date: Project: Qty: Type: ACL ACL. R2 Type II Distribution.

ViewPoint Monitoring Console System

ArmorConnect Power and Control Media

Ravenna TM. Fixture Options: Ordered Separately from Fixture See page 2. Mounting Options: Ordered Separately from Fixture See pages 3-5

Models beginning with 2M, 2L or 2X. Product Description. Technical Specifications. Installation Instructions. Series 2000 Multiple Meter Units (MMUs)

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2

User Manual CV-87K. PS/2 extender over cat.x. rev: Made in Taiwan

GENERAL UL th EDITION BID SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.

FT Flexitest Family. Switches, Covers and Test Plugs

Ravenna TM. Fixture Options: Ordered Separately from Fixture. See page 2. Mounting Options: Ordered Separately from Fixture.

PanelFAST. Setting a new standard for immediate product availability with Square D Ready to Install (RTI) Panelboards

BSPD Surge Protective Devices

ELECTRO-MECH SCOREBOARD CO.

MFA-0801 & MFA-1201 D-M-E Smart Series Low Voltage Temperature Control System. User s Manual. D-M-E Company

Type 4 Disconnect Enclosures

Light Engine. Tilt of. Mounting. Pole Series K. R3W Type III Distribution Wide R3N Type III Distribution Narrow R5 Type V Distribution

K1D004ACH cam switch - 4-pole A - for Ø 22 mm

Service Manual For. -IP Voice over Internet Protocol -ACH** Handset cord length Inches

1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM

STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625

Single-Phase Encapsulated

Medium Voltage Metal-Enclosed Power Capacitor Banks

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

K1K015NZ4 cam stepping switch - 2-pole A - screw mounting

Power-Style QED-2, Series 2 Low Voltage Switchboards

MAXIOM. Data Sheet. Lighting Relay Panel. Overview Leverage the Power of BAS Integration

IRB-MON UNIVERSAL SAFETY PHOTOEYE OPERATING UL MONITORED DEVICE

PRO I Series CAPACITANCE PROBE

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A

Emery County Senior Center Green River 06/07

IEC H.P. Rated Pin and Sleeve Sequential contacts engagement during mating and un-mating IEC configurations specific to each voltage and

SECTION WIRING DEVICES

DOCKING STATION SPECIFICATIONS

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm

3M Indoor Building Entrance Terminal (IBET) 4790V and 4790VL Series

Electrical Integration of PV Systems. Ridha Hamidi, Ph.D.

FOOD AND BEVERAGE AUTOMATION & ELECTRICAL SOLUTIONS

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

Internal Modular SPDs

KTX REMOTE INSTALLATION INSTRUCTIONS

SOUTH CAROLINA ELECTRIC COOPERATIVES SECONDARY TYPE 1 SURGE PROTECTIVE DEVICE SPECIFICATIONS Updated/Revised: October 6, 2014

Basketball Shot Clock Set LX2180 Manual

DP2 DOOR PHONE. For Technical Assistance Please Phone: (07)

SPECIAL SPECIFICATION 6210 Texas Electrical and Lighting Management System (T-ELMS)

PowerPak 2 Power Distribution Unit. Flexible. Configurable. Intelligent. Safe.


VRp Three-Phase Precision AC Voltage Regulator

User Manual rev: Made in Taiwan

Transcription:

GTX TM SUPER YACHT UNIT SUBSTATION General Specifications THE INFORMATION CONTAINED IN THE FOLLOWING DOCUMENT REPRESENTS THE STANDARD CAPABILITIES OF THE GTX TM SUPER YACHT UNIT SUBSTATION. EACH UNIT IS MANUFACTURED TO PROJECT SPECIFICATIONS AND WILL BE MODIFIED ACCORDINGLY. Rev.4 02-17-17 Marina Electrical Equipment, Inc. 100 Warwick Court Williamsburg, VA 23185 Toll Free: 1-855-258-3939 Fax: 1-757-258-3988

ALL SUPER YACHT UNITS SHALL MEET THE FOLLOWING SPECIFICATIONS: SECTION A: ACCEPTABLE MANUFACTURERS: Marina Electrical Equipment, Inc. 100 Warwick Court Williamsburg, VA 23185 Toll Free: 1-855-258-3939 Web: www.marinaelectricalequipment.com SECTION B: GENERAL REQUIREMENTS 1. GTX Super Yacht Unit Substations shall be listed and marked, tested and certified to conform to Standard ANSI/UL 1062 entitled Unit Substations and CAN/CSA Standard C22.2 No. 29 entitled Panelboards and Enclosed Panelboards. 2. Shall be compliant with all sections of the latest edition of NFPA 303, Fire Protection Standards for Marinas and Boatyards. 3. Shall be compliant with NEC, and NFPA 70 406.8 (B)(2)(a), which states: A receptacle installed in a wet location shall be installed in a weatherproof enclosure, the integrity of which is not affected when the attachment plug cap is inserted. 4. Shall be compliant with NEC, and NFPA 70 555.5, which states: Transformers and enclosures shall be specifically approved for the intended location. The bottom of transformers shall not be located below the electrical datum plane. SECTION C: CONSTRUCTION REQUIREMENTS 1. All materials and components used in the construction of the power pedestal shall be listed. 2. Main Housing: Shall be constructed of 316L stainless steel and shall powdercoated with ployester resin and processed to withstand a saltspray without peeling or separating. The housing be listed as a NEMA Type 3R weatherproof enclosure. 3. Access Panels: Shall be constructed of 316L stainless steel and be flush-mounted with minimal external mounting hardware. 4. Lighting Lens: Shall be constructed of 3/16 thick injection-molded listed polycarbonate. 5. Mounting Base: Shall be compliant with NEC and NFPA 70 555, and meet the datum plane requirement without the addition of curbing to meet the 12 height requirement. The housing shall also have isolation pads to insure the housing does not have contact with the mounting substrate (concrete or wood). 6. Top / Lifting: Shall be constructed with a removable solar shield that conceals four (4) engineered lifting shackles that swivel and are designed / tested to lift four (4) times the static weight of the assembly. 7. Mounting Requirements: Mounting bolts (provided by others) for the assembly shall be easy to use and concealed behind removable louvered access panels after mounting. 8. Doors: The housing shall have lockable doors. 9. Fans: Shall be equipped with thermo-statically controlled axial fans to maintain efficient operating temperature. The fans shall also be controlled by an electromechanical photocell to limit condensation build-up created by temperature variations during evening hours. 10. Hardware: Shall be minimal and be 316 stainless steel, Phillips drive. SECTION D: LIGHTING 1. Each GTX Super Yacht Unit Substation shall contain four (4) non-metered lighting assemblies. 2. Lighting assemblies shall be readily available, commercial manufactured, optional LEDs that are controlled by an electromechanical photocell. 3. The LEDs shall be controlled by an electromechanical photocell that is internally mounted with no exposed external components. 4. Lighting assemblies shall be protected by a 20 ampere, single pole circuit breaker or fuse. Rev.4 02-16-17 Page 1

SECTION E: TRANSFORMER 1. Transformer shall meet the requirements of NEMA TP.1 as described in the Code of Federal Regulations Section 451.196 Energy Conservation Standards. 2. Construction shall be ganged torodial transformers with copper windings and termo-statically controlled axial fans to maintain efficient operating temperature. 3. The no load core (iron) losses shall not exceed 650 watts or 0.0027%. SECTION F: PANELBOARD (IF APPLICABLE) 1. The distribution panelboard(s) shall be manufactured by GE, Square-D, or equivalent. 2. The distribution panelboard shall contain an (optional) integral surge protection device (SPD) designed to contain a 100kA surge incident. 3. The distribution panelboard shall contain an (optional) ground fault monitor relay to monitor and/or interrupt the main circuit breaker or branch circuit breakers per NEC 555.3 ground fault protection requirements. SECTION G: RECEPTACLES, CAM-LOCK HARDWIRE, & CIRCUIT BREAKERS 1. Receptacles rated for 100 amperes shall be tin or nickel-plated pin-and-sleeve and conform to IEC and CEE standards. 2. IEC/CEE pin-and-sleeve receptacles shall be ABL-Sursum, Globetron or equivalent. 3. Ground Fault Circuit Interrupting (GFCI) receptacles shall conform to NEMA 5-20R requirements. 4. GFCI Receptacles shall be Leviton SmartLockPro Weather Resistant, corrosion-resistant stainless steel or equivalent. 5. Receptacles shall be mounted at a minimum height of 30 above the deck surface and at a minimum angle of 35 from horizontal for ship-to-shore power cord strain relief. 6. Each receptacle shall be individually protected by a thermal-magnetic type circuit breaker with minimum 10 kaic interrupting rating. 7. Circuit breakers be manufactured by GE, Square-D, or equivalent. 8. Cam-lock hardwire connections shall be equipped with electric safety inter-locking mechanisms to prevent energizing the connections without proper connectivity. SECTION H: SOLID-STATE ELECTRIC kwh MONITORING 1. Each pedestal shall be equipped with solid-state electric monitors which output kilowatt-hours (kwh) consumption at each slip via an electromechanical counter and internally built wireless remote transmission. Wireless transmission shall be integral to the solid state electric monitor. 2. Each solid-state electric monitor shall be rated for 200 amperes, listed, marked and tested to conform to Standard ANSI-C12.1 and NTEP standards with ±1% accuracy. 3. Each solid-state electric monitor shall be capable of monitoring ground faults at each slip. 4. Each solid-state electric monitor shall measure the analog pulse output of the water meters at each slip and wirelessly transmit the gallon usage via the internally built wireless remote transmission. Wireless transmission via thrid-party vendors is not acceptable. SECTION I: WIRING & TERMINAL BLOCK 1. Unit substations shall be completely factory pre-wired to the load side of the copper 3/8 stud lug compression terminal block assembly and/or integral panelboard(s) main lugs and/or branch feeder circuits. 2. Electrical wiring shall be high-stranding tin-plated copper THHW/MTW VW-1 Boat Cable rated for 105 C. 3. All electrical components shall be located above the electrical datum plane set forth by the NEC. 4. All exposed metallic parts shall be grounded as part of the integral equipment ground. Rev.4 02-16-17 Page 2

SECTION J: PLUMBING 1. Each pedestal shall be capable of providing single or dual 3/4" IPS ball valve hose bibs. 2. Plumbing connections must be partitioned from all electrical wiring/components by an integral partition box. 3. Each ball valve hose bib shall be metered (optional) (with or without analog display at at the pedestal) and have the gallon per slip usage wirelessly transmitted via an internally built wireless remote transmitter that is integral to the monitor. Wireless transmission via third-party vendors is not acceptable. SECTION K: WARRANTY 1. The main housing and attached parts (main housing, access panels, solar shield, lenses, doors, receptacle faceplates, and circuit breaker plates) will be free from failure resulting from defects in material and/or workmanship, and are covered by a limited warranty of one (1) year. The warranty is voided if any petroleum-based solvent is used anywhere on or near any of the polycarbonate parts. These parts include: main housing, access panels, solar shield, lenses, doors, receptacle faceplates, and circuit breaker plates. 2. Internal electrical components shall be covered by a limited warranty of one (1) year. Items covered include: torodial transformers, panelboards, fans, receptacles, circuit breakers, photocells, lamp holders, coil transformers, counters and wiring harnesses. 3. The solid-state electric kwh monitors will be free from failure resulting from defects in material and/or workmanship, and are covered for one (1) year. The warranty shall not cover the product against severe over-voltage conditions such as lightning strikes or abnormal utility surges. The warranty is voided if the damage to any or all of the components is the result of abuse, misuse, or Force Majeure. This warranty is voided if the factory seal is broken or manipulated. Specifications Subject to Change Without Notice END OF SECTION Rev.4 02-16-17 Page 3

300 300 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TYPICAL FRONT VIEW w/ DOORS CLOSED REMOVABLE SOLAR SHIELD LOUVERED LIGHTING 100A PIN & SLEEVE RECEPTACLE HEIGHT VARIES W/ UNIT CONFIG PRIMARY SECTION (480V) PANELBOARD ACCESS (LOCKABLE) REMOVABLE LOUVERED FRONT ACCESS PANEL LOCKABLE LATCHES DIMENSIONS DETERMINED BY UNIT CONFIGURATION 3/4" IPS BALL-VALVE HOSE BIBB SECONDARY SECTION (208Y/120V, 220Y/127V, or 120/240V, etc.) PANELBOARD ACCESS (LOCAKABLE) STANDARD 12" BASE HEIGHT TO COMPLY WITH 12" DATUM PLANE REQUIREMENTS TYPICAL PRIMARY SECTION SIDE VIEW TYPICAL SECONDARY SECTION SIDE VIEW CAM-LOCKS FOR HARDWIRE W/ SAFETY INTERLOCK 316L STAINLESS STEEL N3RX ENCLOSURE LOUVERED LIGHTING kwh METER COUNTER REMOVABLE ACCESS PANELS WITH NO EXTERNAL HARDWARE 20A 125V GFCI RECEPTACLES UNDER COVERS FAN EXHAUST COVER OPTIONAL TELECOM. PORTS 3/4" IPS BALL-VALVE HOSE BIBBS w/ OPTIONAL GAL. METERING REMOVABLE LOUVERED ACCESS PANEL PRIMARY SECTION MAIN (MCB or MLO), FIELD-TERMINATION POINT SECONDARY SECTION MAIN (MCB or MLO), FACTORY-WIRED TO RECEPTACLES OPTIONAL PRIMARY SECTION GROUND FAULT MONITOR/ INTERRUPTER OPTIONAL SECONDARY SECTION GROUND FAULT MONITOR/ INTERRUPTER PRIMARY SECTION BRANCH CIRCUIT BREAKERS, FACTORY-WIRED TO RECEPTACLES & TRANSFORMER SECONDARY SECTION BRANCH CIRCUIT BREAKERS, FACTORY-WIRED TO RECEPTACLES FRONT VIEW w/ DOORS OPEN & FRONT ACCESS PANELS REMOVED Rev.4 02-16-17 Page 4

LIFTING SHACKLES CONCEALED UNDER SOLAR SHIELD REMOVABLE ACCESS PANEL MOUNTING SLOT FOR REMOVABLE ACCESS PANEL WITH NO EXTERNAL HARDWARE REMOVABLE SOLAR SHIELD FOR LIFTING SHACKLE ACCESS PHOTOCELL THERMOSTATICALLY- CONTROLLED AXIAL FANS CONCEALED UNDER FAN EXHAUST COVERS COPPER WOUND TOROIDAL TRANSFORMER REMOVABLE LOWER REAR ACCESS PANEL TYPICAL REAR VIEW w/ ACCESS PANELS REMOVED TO EXPOSE TORODIAL TRANSFORMERS TYPICAL MOUNTING FOOTPRINT FOUR (4) CONCEALED Ø0.50" MOUNTING SLOTS PRIMARY SECTION SECONDARY SECTION DEPTH DETERMINED BY UNIT CONFIGURATION PRIMARY SECTION CONDUIT/CABLE ENTRY OPENING WITH REMOVABLE ALUMINUM GLAND PLATE WIDTH DETERMINED BY UNIT CONFIGURATION WIDTH DETERMINED BY UNIT CONFIGURATION SECONDARY SECTION CONDUIT/CABLE ENTRY OPENING WITH REMOVABLE ALUMINUM GLAND PLATE Rev.4 02-16-17 Page 5

IMPORTANT: HANDLING / LIFTING 1. LIFTING SHACKLE METHOD: This lifting assembly has been tested at a load of four times the static weight of the GTX Super Yacht Unit Substation. The lifting shackles are located under the solar shield. The solar shield can be removed can removing the screws located around the lower edge of the shield. 2. FORKLIFT METHOD: Lifting slots are provided on each end of the GTX Super Yacht Unit Substation. Remove the lower access panels on front and rear of the unit. Use fork extensions so that the forks are spread to the outside of the slots, making sure that the forks extend past the end of the assembly. Forks that do not completely extend through could damage internal components and/or result in imbalance, unit damage, injury/death. Forklift access can also be accomplished from the left and rear sides of the unit with the removal of the lower access panels. MOUNTING 1. Remove the front and rear lower access panels on the bottom of the GTX Super Yacht Unit Substation. This will expose the mounting holes at the bottom of the unit. Do not remove the neoprene pad from the bottom of the unit. The neoprene pads provide isolation from the dock surface. A <60 C B IMPORTANT: WHEN LIFTING THE GTX SUPER YACHT UNIT SUBSTATION, THE SPREADER ANGLE MUST BE LESS THAN 60 (LEGS A AND B MUST BE LONGER THAN LEG C). LIFTING SHACKLES DESIGNED / TESTED TO LIFT FOUR (4) TIMES STATIC WEIGHT FRONT VIEW w/ SOLAR SHIELD REMOVED TO EXPOSE LIFTING SHACKLES REMOVABLE LOWER ACCESS PANEL FRONT VIEW w/ ACCESS PANELS REMOVED TO EXPOSE FORKLIFT LIFTING SLOTS Rev.4 02-16-17 Page 6