Fan coil (FCU) application guide

Similar documents
Application Guide. Fan Coil (FCU) Application Guide. VTR8000 Series Room Controllers. Control Performance Energy savings Better building management

ExactLogic BACnet Communicating Pressure Dependent VAV Damper Control with Heat EXL01820 Sequence Datasheet

ExactLogic BACnet Communicating Zone Damper EXL01710 Sequence Datasheet

VTR8300 User Interface Guide VTR8300 Room Controller Series

CONTENTS. Installation Guide. PIR Ready VT7200 Series 24 VAC Low Voltage Zoning Terminal Equipment Controller

ExactLogic BACnet Communicating Thermostat EXL01816 Sequence Datasheet

SE8300 User Interface Guide SE8300 Series Room Controller

Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification

Product comparison guide

Room Controllers. SC3000 Relay Pack

SE7600E Series Application Guide

SEZ7000 Series. Wireless Commercial Zoning System

SER8300 Room Controller

VZ7260X5X00W BACnet Zone Room Controller. Installation Guide. April 2017

ExactLogic BACnet Communicating Thermostat EXL01716 Sequence Datasheet Duel Deck VAV

SE8300 User Interface Guide Commercial and Hotel/Lodging HVAC Fan Coil Applications

March 13 th, 2012 / R2

SE8300 Room Controller

Room Controllers VTR8300 Line Voltage Fan Coil Controller with VC3000 Relay Pack Technical Cut Sheet

SE7600E Series Application Guide

FCU-4 FAN COIL CONTROLLER

Modbus Integration Integration for Modbus Functionality for VTR8300 Series

SEZ7260X5x45B Installation Guide for BACnet MS/TP Zone Controller

VZ7000 Series. BACnet Commercial Zoning System

SmartStruxure SmartStruxure Lite ZENO InnPoint. ZENOcontrols.com. compatible with

Room Controllers SER8300 Line Voltage Fan Coil Controller with SC3000 Relay Pack

Room Controllers. SER8300 Line Voltage Fan Coil Room Controller with SC3000 Relay Pack

VT8600 Series User Interface Guide Rooftop Unit, Heat Pump and Indoor Air Quality Controller

Communicating Thermostats. Add More Flexibility to Building Automation with. Communicating Thermostats

SE8000 Series BACnet Integration

FCU-4 FAN COIL CONTROLLER

VTR8300 User Interface Guide Commercial and Hotel/Lodging HVAC Fan Coil Applications

Room Controllers SER8300 Line Voltage Fan Coil Controller with SC3000 Relay Pack

Room controller STRA-17

SER8300 / SE8300 Series BACnet Integration Terminal Equipment Controller

Firmware Upgrade Release Notes. Release Notes for VT8000 Series Room Controllers

SER8300 User Interface Guide SER8300 Series Room Controller

RCF-230CAD. Room controller with communication for fancoil applications with two analogue V DC outputs

Submittal Data Sheet intelligent Touch Manager DCM601A71

MANUAL INSTALLATION + SERVICE. Price Intelligent Controller. PIC Series. v400 Issue Date: 12/18/ Price Industries Limited. All rights reserved.

BACnet PTEC Controller Constant Volume - Cooling Only, Application Application Note Building Technologies

TEC Zoning Control System for Stand-Alone and BACnet MS/TP Networked Applications

SmartStruxure Lite solution Get Control. Get Efficient. Get Value.

FCU-MULTI Modbus Fan Coil Unit Controller

RS-485 Modbus RTU Networking Room Thermostats with LCD for Fan Coil Units

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

RCF-230CTD. Built-in or external sensor The controller has a built-in sensor. Alternatively, the input for an external PT1000-sensor can be used.

Pre-programmed room controller with display and communication

Desigo RXA Room controllers without bus communications Range overview. CA2S3880en_ Building Technologies

RCF-230CD. Communicating room thermostat for fan-coil applications with on/off outputs

Viconics Zoning System Application Guide VZ7200F5x00W and VZ7656B1000W Thermostats

Installation Guide. VZ7656F1000B BACnet MS-TP RTU Terminal Equipment Controller with Modulating Heat. February 2017 /

Pre-programmed room controller with display and communication

The Bard BrightStat Room Controllers

Application program: description and examples

VZ7656F1000W Zigbee Wireless RTU Terminal Equipment Controller with Modulating Heat. Installation Guide

Field selectable application type and room module series, via dip-switches on controller

BACnet Integration Manual September 1, 2010

RS-485 FClink Networking Room Thermostats with LCD for Fan Coil Units

RCF-230CTD. Room controller for fan-coil applications with outputs for two thermal or one 3-position actuator or function for an electric heater

RCF-230CAD. Communicating room controller for fan-coil applications with two analogue V DC outputs

Room Controller. SE8300 Low Voltage Fan Coil Controller and Zone Controller

RC-CDTO. Pre-programmed room controller with display, communication and three-point control

SE8000 Series BACnet Integration

HLS34 Modbus FCU/VAV Controllers installation instructions

Installation and Operation. Tracer MP501 Controller CNT-SVX08B-EN

VT7200 Series 24 Vac Low Voltage Zoning Thermostats For Commercial HVAC Applications

SE8000 Series BACnet Integration Terminal Equipment Controller. Commercial and Lodging HVAC Applications

FOCUS GUIDE VAV ZONE CONTROLLER. Configuration Guide for ProLon Focus Software

Measure & Control Temperature & CO2 levels with analog & digital I/O

BACnet Integration Manual ITG-VWG-50-BAC-E01.doc ( R1 Issue Date: January 10 th, 2012)

Tracer Controls. Tracer MP501 Controller BAS-PRC008-EN. January 2005

VTR8300 / VT8300 Series BACnet Integration Terminal Equipment Controller

NT50 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat

Viconics BACnet Zoning System Application Guide VZ7260X5x00B and VZ7656X5000B Controllers

Evolution TH. Pre-configured controller with display, clock and communication. Evolution. Applications. TH version. Sensors

Temperature Controller (Heat Pumps)

TAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta

Networkable Dual Duct VAV Controller Specification and Installation Instructions

Temperature controller Ducted systems

Tracer Controls. Tracer MP.501 Controller BAS-PRC008-EN. June 2001

BACnet Product Overview

STRA-17 Room controller. Installation and maintenance manual. Content

NT10 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat

VZ7656R1000W / VZ7656H1000W Zigbee Wireless RTU / HP Terminal Equipment Controllers. Installation Guide

VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide

TF243 Series Digital Thermostat Fan Coil Unit Control

ENERGY-INTELLIGENT TECHNOLOGY HEATING AND COOLING SYSTEMS INTELLIGENT TOUCH MANAGER ONE FOR ALL ADVANCED MULTI-ZONE CONTROLLER

VZ7656B1000W Series Wireless RTU Thermostats For Commercial Zoning Systems

CONTROLLER INSTALLATION OPERATION & QUICK START

VZ7656B1000B Series BACnet RTU Thermostats For Commercial Zoning Systems

RS-485 Modbus RTU Networking FCU Thermostats with 0(2)-10 VDC Fan Output

Product Catalog. Tracer Controller MP501 BAS-PRC008-EN. May 2012

VTR8300 / VT8300 Series BACnet Integration Terminal Equipment Controller

Introduction. To use Carrier wireless sensors, you must have: A i-vu v6.5 or later system v6-00 or later drivers

Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller

VZ7656E1000W Zigbee Wireless RTU Terminal Equipment Controller with IAQ Control. Installation Guide

CCM-204 MULTI-PURPOSE TEMPERATURE CONTROLLER

intelligent TOUCH MANAGER ONE FOR ALL ADVANCED MULTI-ZONE CONTROLLER

BACnet Integration Manual ITG-VZ7xxx-BAC-E04.doc ( _R4 Issue Date: May 31 st, 2012)

Transcription:

Fan coil (FCU) application guide SE7000 Series room controllers Control Performance Energy savings Better building management

Table of contents Product & application selector... 4 Cost-saving, energy-saving applications... 8 VC7000 network ready communication adapters...10 SE7350C5045: eating/cooling: 4-pipe fan coil unit with 3-speed fan, tri-state floating valves and dehumidification sequence...12 SE7300C5045: eating/cooling with changeover and reheat: 2-pipe fan coil unit with 3-speed fan, tri-state floating valve and electric reheat...14 SE7350F5045: eating/cooling: 4-pipe fan coil unit with 3-speed fan, 0-10 VDC Analogue valves and dehumidification sequence...16 SE7355C5045: eating/cooling: 4-pipe fan coil unit with 3-speed fan, 2-position valves, and dehumidification sequence...18 SE7300C5045: Cooling only: 2-pipe fan coil unit with single speed fan, 2-Position cooling valve and fresh air damper...20 SE7300F5045: heating/cooling with changeover sensor and reheat: 2-pipe fan coil unit with 3-speed fan, analogue valve, and electric reheat...22 SE7300F5045: Cooling with reheat: 4-pipe fan coil unit with 3-speed fan, analogue cooling valve and on/off heating valve...24 SE7300F5045: Cooling only: 2-pipe fan coil unit with 3-speed fan and 0-10 VDC analogue cooling valve...26 SE7300C5045: Cooling with reheat: 2-pipe fan coil unit with 3-speed fan, 2-position valve and electric reheat...28 SE7350F5045: eating/cooling: 4-pipe fan coil unit with 3-speed fan, 0-10 VDC analogue valves and dehumidification sequence... 30 SE7350C5045: eating/cooling: 4-pipe fan coil unit with 3-speed fan, 2-position valves, and dehumidification sequence...32 SE7350C5045: eating/cooling: 4-pipe fan coil unit with 3-speed fan, tri-state floating valves and dehumidification sequence... 34 2 Schneider Electric Fan coil application guide

SE7300A5045 - SC3500E5045: eating/cooling: 4-pipe fan coil unit with 3-speed fan, 2-position valves with wireless door switch... 36 SE7350A5045 - SC3404E5045: Cooling and electric heat: 2-pipe fan coil unit with 3-speed fan, dehumidification, 2-position valves... 38 SE7300A5045 - SC3504E5045: eating/cooling with changeover sensor: 2-pipe fan coil unit with 3-speed fan and wirelesss window switch... 40 SE7350A5045 - SC3400E5045: Cooling and electric heat: 2-pipe fan coil unit with 3-speed fan and dehumidification, 2-position valves...42 SE7300A5545 - SC3514E5045: eating/cooling: 2-pipe fan coil unit with 3-speed fan and fresh air damper, 2-position valves... 44 SE7300A5045 -SC3500E5045 -SC3300E5045: eating/cooling: 4-pipe fan coil unit with 3-speed fan, 2-position valves with slave relay pack... 46 SE7300A5045 - SC3504E5045: Cooling and electric heat: 2-pipe fan coil unit with 3-speed fan, 2-position valves with wired window switch... 48 SE7300A5045 - SC3500E5045: eating/cooling: 4-pipe fan coil unit with 3-speed fan, 2-position valves with wired door switch... 50 Appendix A - Passive infra-red (PI) motion detector cover specifications... 53 Appendix B - option network wiring if communicating models are used... 54 Appendix C - controllers occupancy sequence of operation schematic... 54 Appendix D - VWA5000 series - wireless door & window switch... 55 Appendix E - SE7300 controller & SC3000 relay pack...57 Appendix F - SE7300 low voltage fan coil controller...59 www.schneider-electric.com 3

Product & application selector SE7300 & elay Pack Power Building Function umidity Control Application Outputs / Inputs Controller elay Pack Typical Application ine Voltage mercial Yes 2 or 4 pipe, Up to 3 speed fan 1/1C with eheat SE7350A5045 SC3500E5045 Page: 38, 42 1/1C with 4 inputs and reheat SE7350A5045 SC3504E5045 Page: 40, 44 1/1C with 4 inputs reheat and occ. output SE7350A5045 SC3514E5045 Page: 44 No 2 Pipe, Up to 3 speed fan 1/1C with pulsed reheat SE7300A5045 SC3400E5045 Page: 42 1/1C with pulsed reheat and 4 inputs SE7300A5045 SC3404E5045 Page: 38 ospitality Yes 2 or 4 pipe, Up to 3 speed fan 1/1C with eheat 1/1C with 4 inputs and reheat SE7355A5045* SC3500E5045 Page: 36, 50 SE7355A5045* SC3504E5045 Page: 40, 48 1/1C with 4 inputs reheat and occ. output SE7355A5045* SC3514E5045 Page: 44 No 2 Pipe, Up to 3 speed fan 1/1C with pulsed reheat SE7305A5045* SC3400E5045 Page: 42 1/1C with pulsed reheat and 4 inputs SE7305A5045* SC3404E5045 Page: 38 Slave fan control only 3 fan outputs SE73xxA5045 SC3300E5000 Page: 46 *The ospitality/odging models are identical to the commercial controllers except for the Override key which is replaced with a C/ F key to switch between Celsius and Fahrenheit units. At the end of the model number, add B for BACnet communication or W for Zigbee wireless communication. Ex: SE7300A5045B or SE7300A5045W 4 Schneider Electric Fan coil application guide

SE7300 and SCs Fan coil terminal equipment controllers This new cost-effective solution for upgrading line-voltage fan coil unit thermostats requires only two components: the SE7300 terminal equipment controller and the SC3000 relay pack. This solution allows existing line voltage wiring between the fan coil unit and temperature controller to be re-used, reducing overall costs and installation time. The SC3000 relay pack features an onboard universal voltage power supply and line-voltage relays which directly drive fractional horsepower fan motors and valves. This eliminates the need to install and wire costly pilot relays and transformers. mercial interface (local override) Part Number Description umidity PI Cover munication SE7300A5045 Stand-alone fan coil terminal equipment controller No No Stand-alone (network ready) SE7300A5045B BACnet fancoil terminal equipment controller No No BACnet SE7300A5045W Wireless fan coil terminal equipment controller No No Wireless SE7300A5545 Stand-alone fan coil terminal equipment controller No Yes Stand-alone (network ready) SE7300A5545B BACnet fan coil terminal equipment controller No Yes BACnet SE7300A5545W Wireless fan coil terminal equipment controller Yes Yes Wireless SE7350A5045 Stand-alone fan coil terminal equipment controller Yes No Stand-alone (network ready) SE7350A5045B BACnet fancoil terminal equipment controller Yes No BACnet SE7350A5045W Wireless fan coil terminal equipment controller Yes No Wireless SE7350A5545 Stand-alone fan coil terminal equipment controller Yes Yes Stand-alone (network ready) SE7350A5545B BACnet fan coil terminal equipment controller Yes Yes BACnet SE7350A5545W Wireless fan coil terminal equipment controller Yes Yes Wireless otel/lodging interface ( C/ F selection) Part Number Description umidity PI Cover munication SE7305A5045 Stand-alone fan coil terminal equipment controller No No Stand-alone (network ready) SE7305A5045B BACnet fancoil terminal equipment controller No No BACnet SE7305A5045W Wireless fan coil terminal equipment controller No No Wireless SE7305A5545 Stand-alone fan coil terminal equipment controller No Yes Stand-alone (network ready) SE7305A5545B BACnet fan coil terminal equipment controller No Yes BACnet SE7305A5545W Wireless fan coil terminal equipment controller Yes Yes Wireless SE7355A5045 Stand-alone fan coil terminal equipment controller Yes No Stand-alone (network ready) SE7355A5045B BACnet fancoil terminal equipment controller Yes No BACnet SE7355A5045W Wireless fan coil terminal equipment controller Yes No Wireless SE7355A5545 Stand-alone fan coil terminal equipment controller Yes Yes Stand-alone (network ready) SE7355A5545B BACnet fan coil terminal equipment controller Yes Yes BACnet SE7355A5545W Wireless fan coil terminal equipment controller Yes Yes Wireless Transformer relay packs for fan coil units Part Number Description SC3300E5045 SC3400E5045 SC3404E5045 SC3500E5045 SC3504E5045 SC3514E5045 Transformer relay pack four relay outputs and smart VDC output Transformer relay pack four relay outputs, smart VDC output, and four inputs Transformer relay pack three slave fan outputs Wireless accessories for SE7300 Series Part Number VWA5000D5045W VWA5000W5045W Description Wireless door switch Wireless window switch www.schneider-electric.com 5

SE7300 Fan coil room controllers Power Application Building Function umidity Control Outputs / Inputs Controller Typical Application ow Voltage - 2 or 4 Pipe - ot/chill water valves mercial Yes On-Off 1/1C SE7350C5045 Page: 20, 32 - Up to 3 speed fan Floating 1/1C SE7350C5045 Page: 12, 34 - Automatic Changeover -Auxiliary contact output Analogue 1/1C SE7350F5045 Page: 16, 30 No On-Off 1/1C SE7300C5045 Page: 28 Floating 1/1C SE7300C5045 Page: 14 Analogue 1/1C SE7300F5045 Page: 22, 24, 26 ospitality / odging Yes On-Off 1/1C SE7355C5045* Page: 18, 20, 32 Floating 1/1C SE7355C5045* Page: 12, 34 Analogue 1/1C SE7355F5045* Page: 16, 30 No On-Off 1/1C SE7305C5045* Page: 28 Floating 1/1C SE7305C5045* Page: 14 Analogue 1/1C SE7305F5045* Page: 22, 24, 26 *The ospitality/odging models are identical to the commercial controllers except for the Override key which is replaced with a C/ F key to switch between Celsius and Fahrenheit units. Note: At the end of the model number, add B for BACnet communication, E for Echelon communication or W for Zigbee wireless communication. Ex: SE7300A5045B or SE7300A5045E or SE7300A5045W 6 Schneider Electric Fan coil application guide

SE7300 Fan coil room controllers Achieve better energy efficiency and reduce operating costs with SE7300 Series room controllers. Ideal for commercial and hotel applications, these fan coil units function with electronically commutated motors to optimise fan control sequences. With the full proportional operating of the SE7300, as opposed to the traditional three-speed tap operation, customers will experience better control and a more comfortable environment. mercial interface (local override) Part Number Description umidity Output PI Cover munication SE7300C5045 Stand-alone fan coil controller No Floating or on/o No Stand-alone (network ready) SE7300C5045B BACnet fan coil controller No Floating or on/o No BACnet SE7300C5045E fan coil controller No Floating or on/o No onworks SE7300C5045W Wireless fan coil controller No Floating or on/o No Wireless SE7300C5545 Stand-alone fan coil controller No Floating or on/o Yes Stand-alone (network ready) SE7300C5545B BACnet fan coil controller No Floating or on/o Yes BACnet SE7300C5545E fan coil controller No Floating or on/o Yes onworks SE7300C5545W Wireless fan coil controller No Floating or on/o Yes Wireless SE7300F5045 Stand-alone fan coil controller No 0-10 V No Stand-alone (network ready) SE7300F5045B BACnet fan coil controller No 0-10 V No BACnet SE7300F5045E fan coil controller No 0-10 V No onworks SE7300F5045W Wireless fancoil controller No 0-10 V No Wireless SE7300F5545 Stand-alone fan coil controller No 0-10 V Yes Stand-alone (network ready) SE7300F5545B BACnet fan coil controller No 0-10 V Yes BACnet SE7300F5545E fan coil controller No 0-10 V Yes onworks SE7300F5545W Wireless fan coil controller No 0-10 V Yes Wireless SE7350C5045 Stand-alone fan coil controller Yes Floating or on/o No Stand-alone (network ready) SE7350C5045B BACnet fan coil controller Yes Floating or on/o No BACnet SE7350C5045E fan coil controller Yes Floating or on/o No onworks SE7350C5045W Wireless fan coil controller Yes Floating or on/o No Wireless SE7350C5545 Stand-alone fan coil controller Yes Floating or on/o Yes Stand-alone (network ready) SE7350C5545B BACnet fan coil controller Yes Floating or on/o Yes BACnet SE7350C5545E fan coil controller Yes Floating or on/o Yes onworks SE7350C5545W Wireless fan coil controller Yes Floating or on/o Yes Wireless SE7350F5045 Stand-alone fan coil controller Yes 0-10 V No Stand-alone (network ready) SE7350F5045B BACnet fan coil controller Yes 0-10 V No BACnet SE7350F5045E fan coil controller Yes 0-10 V No onworks SE7350F5045W Wireless fan coil controller Yes 0-10 V No Wireless SE7350F5545 Stand-alone fan coil controller Yes 0-10 V Yes Stand-alone (network ready) SE7350F5545B BACnet fan coil controller Yes 0-10 V Yes BACnet SE7350F5545E fan coil controller Yes 0-10 V Yes onworks SE7350F5545W Wireless fan coil controller Yes 0-10 V Yes Wireless The ospitality/odging models are identical to the commercial controllers except for the Override key which is replaced with a C/ F key to switch between Celsius and Fahrenheit units.the only difference in the p/n is that the 6th character is a 5 instead of a zero - Example: SE7305 rather than SE7300. www.schneider-electric.com 7

Cost-saving, energy-saving applications From hotels and hospitals to schools, retail, and commercial buildings, Schneider Electric offers wide-ranging room control solutions for your building management needs. Whether retrofitting current systems with a more technologically advanced room controller or going green with a more environmentally friendly option, SE7000 Series is the ideal, cost-competitive solution. The SE7000 Series room controllers can be equipped with an integrated passive infrared motion sensor for demandbased occupancy control that opens up new opportunities in smart energy management. Open communications Advance control of your building with truly open, integrated communications. Open protocol options include Zigbee wireless, BACnet, and onworks infrastructure. Occupancy sensing Equip your room controller with an integrated passive infrared motion sensor for demand-based occupancy control that raises your energy new level. ower total install cost Accelerate your return on investment by saving time and resources from the beginning. Our easy-to-install systems integrate into any new or existing building, with no requirement for costly, specialised labor. Efficient control Take full control of your building s VAC equipment. We ll make it simple with intuitive, application-based Energy savings Save energy. Save money. With SE7000 Series room controllers you ll reduce energy comfort one bit. Temperature and humidity sensing measureable control. If you can measure it, you can control it providing more precise occupant comfort and productivity. designed for your needs. 8 Schneider Electric Fan coil application guide

Energy savings for a healthy bottom line. Increase the comfort of patients, visitors, and employees while reducing energy consumption with SE7000 Series room controllers. www.schneider-electric.com 9

VC7000 network ready communication adapters All current Network eady Schneider-Electric SE7000 controllers are capable of being retrofit in the field with accessory communication adapters that enables the controllers to be integrated into virtually all leading building automation systems This approach allows the flexibility to add network communication strategies as budgets allow or as the buildings needs change. If required, Network eady (stand-alone) Terminal Equipment Controllers can be field retrofitted with the following communication adapters. 10 Schneider Electric Fan coil application guide

fortable workers are more productive. Accelerate your return on investment with SE7000 Series room controllers. www.schneider-electric.com 11

SE7350C5045: eating/cooling: 4-pipe fan coil unit with 3-speed fan, tri-state floating valves and dehumidification sequence Cooling Coil eating Coil Tri-state Floating Valve Tri-state Floating Valve Optional PI cover: COV-PI-FCU-C-5045. efer to Schneider Electric Catalogue for valves and actuators. Configuration parameter name SE7350C Configuration settings 12 Schneider Electric Fan coil application guide PswrdSet 0 is factory set, range is: 0-1000 BI1 BI2 UI3 enuscro Autoode C or F As per user. Default value = F % disp ockout As per user. Default value = 0 No lock Pipe No 4.0 CntrlTyp Floating SeqOpera 4 = Cooling / eating 4 pipes Fan enu 2 DumiCK % set As per user. Default value = 50%. ange = 30% to 95% Dehuyst As per user. Default value = 5%. ange = 2% to 20% DehuCool As per user. Default value = 100%. ange = 20% to 100% St-By T 0.5 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments Unocc T 0.0 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments St-By T 69 F is factory set, range is: 40 to 90 F ( 4.5 to 32.0 C ) St-By C 78 F is factory set, range is: 54 to 100 F ( 12.0 to 37.5 C ) Unocc T As per user. Default value = 62 F ( 17 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) Unocc C As per user. Default value = 80 F ( 27 C ). ange = 54 to 100 F ( 12 to 37.5 C ) heat max As per user. Default value = 90 F ( 32 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) cool min As per user. Default value = 54 F ( 12 C ). ange = 54 to 100 F ( 12 to 37.5 C ) Pband 2 F is factory set, range is: 2 to 10 F ( 0.6 to 5.6 C ) Set Type Permanent SptFunc Dual Stp or AttchStp TOccTime As per user. Default value 2 hours. ange = 0 to 24 hours DoorTime N/A deadband As per user. Default value 2.0 F ( 1.0 C ). ange = 2, 3, 4 or 5 F, 1.0 F increments ( 1.0 to 2.5 C, 0.5 C increments ) cal S 0 F or C cal 0 F or C aux cont 0 Auto Fan AS or AS AD F time As per user. Default value = 1.5 minutes. ange 0.5 to 9.0 in 0.5 minutes increments cph N/A eheat 0 for /OFF ( 4CP ), 1 for PW ( 10 second ) UI3 dis Displays supply air temperature

Sequence of operation and wiring Occupied ode: occupied cooling and heating. The changeover sensor will send the supply air temperature to the controller. Stand-by ode (only available when PI motion detector cover is used): standby cooling and heating. Unoccupied ode: unoccupied heating and cooling. Occupied Override ode: The system will revert to occupied mode for the duration determined by the ToccTime parameter. On a call for cool: SE7350C Controller CO - - - BO1 BO2 BO3 BO4 Close Open EATING Close Open COOING Fan coil relay control center (Generic) AC - 230VAC 120V To Fan Coil Unit Cooling valve will modulate to maintain room temperature. eating valve is closed. Dehumidification is enabled. On a call for heat: eating valve will modulate to maintain room temperature. Cooling valve is closed. Dehumidification is disabled. Dehumidification /OFF Sequence: ysterisys = 10% (adjustable) 1/2 ysterisys = 5% 1/2 ysterisys = 5% Dehumidification = On a demand for dehumidification: Dehumidification is achieved via the cooling coil using the heating coil for reheat if necessary. Dehumidification is only allowed in COO mode (or if cooling is enabled in AUTO mode). OFF Dehumidification = OFF % Setpoint Dehumidification is disabled if the room temperature falls below the low ambient lockout temperature. Which is the cooling setpoint minus the configuration defined deadband value. eheat is disabled if cooling demand reaches 100%. Options BACnet, Echelon and Wireless communication models available (see Appendix B for network wiring). emote wall mount or duct sensor ready. Analogue outputs available (SE73xxF5045). Can be configured for 2 pipe systems. Binary inputs can be configured to control occupancy via door or window contact, remote night setback or to provide alarms for service or filter monitoring. Universal input can be configured for a changeover sensor. www.schneider-electric.com 13

SE7300C5045: eating/cooling with changeover and reheat: 2-pipe fan coil unit with 3-speed fan, tri-state floating valve and electric reheat. eating/cooling Coil Sensor: 10K Ohm Type 2. Floating Valve Optional PI cover: COV-PI-FCU-C-5045. efer to Schneider Electric Catalogue for valves and actuators. SE7300C Configuration parameter name Configuration settings PswrdSet 0 is factory set, range is: 0-1000 BI1 BI2 UI3 COS enuscro Autoode C or F As per user. Default value = F ockout As per user. Default value = 0 No lock Pipe No 2.0 CntrlTyp Floating SeqOpera 2 = Cooling with eheat Fan enu 2 St-By T 0.5 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments Unocc T 0.0 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments St-By T 69 F is factory set, range is: 40 to 90 F ( 4.5 to 32.0 C ) St-By C 78 F is factory set, range is: 54 to 100 F ( 12.0 to 37.5 C ) Unocc T As per user. Default value = 62 F ( 17 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) Unocc C As per user. Default value = 80 F ( 27 C ). ange = 54 to 100 F ( 12 to 37.5 C ) heat max As per user. Default value = 90 F ( 32 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) cool min As per user. Default value = 54 F ( 12 C ). ange = 54 to 100 F ( 12 to 37.5 C ) Pband 2 F is factory set, range is: 2 to 10 F ( 0.6 to 5.6 C ) Set Type Permanent SptFunc Dual Stp or AttchStp TOccTime As per user. Default value 2 hours. ange = 0 to 24 hours DoorTime N/A deadband As per user. Default value 2.0 F ( 1.0 C ). ange = 2, 3, 4 or 5 F, 1.0 F increments ( 1.0 to 2.5 C, 0.5 C increments ) cal S 0 F or C cal 0 F or C aux cont 0 Auto Fan AS or AS AD F time As per user. Default value = 1.5 minutes. ange 0.5 to 9.0 in 0.5 minutes increments cph N/A eheat 0 for /OFF ( 4CP ), 1 for PW ( 10 second ) UI3 dis Displays supply air temperature 14 Schneider Electric Fan coil application guide

Sequence of operation and wiring Occupied ode: occupied cooling and heating. The changeover sensor will send the supply air temperature to the controller. Stand-by ode (only available when PI motion detector cover is used): standby cooling and heating. Unoccupied ode: unoccupied heating and cooling. Occupied Override ode: The system will revert to occupied mode for the duration determined by the ToccTime parameter. On a call for cool: If water temperature is less than 24 C (75 F), valve will open to allow water flow. If supply air temperature is greater than 25 C (77 F), valve will close. Baseboard is always desactivated. On a call for heat: If water temperature is less than 24 C (75 F), valve will close and the duct heater will be activated. If water temperature is greater than 25 C (77 F), valve will open to allow water flow. If the water flow is unable to satisfy the demand, the baseboard is activated. SE7300C Controller BO5 BO5 CO - - - BO1 BO2 Scom UI3 Perimeter eating Fan coil relay control center (Generic) AC - 230VAC C/O Sensor actuator Cooling/heating valve 120V To Fan Coil Unit Options BACnet, Echelon and Wireless models available (see Appendix B for network wiring). Analogue 0-10 VDC outputs available (SE73xxF5045). emote wall mount or duct sensor ready. Can be configured for 4 pipe systems. Can be configured to single or two speed fan. Binary inputs can be configured to control occupancy via door or window contact, remote night setback or to provide alarms for service or filter monitoring. www.schneider-electric.com 15

SE7350F5045: eating/cooling: 4-pipe fan coil unit with 3-speed fan, 0-10 VDC Analogue valves and dehumidification sequence Cooling Coil eating Coil Analogue Cooling Valve Analogue eating Valve Optional PI cover: COV-PI- FCU-C-5045. SE7350F efer to Schneider Electric Catalogue for valves and actuators. Configuration parameter name Configuration settings 16 Schneider Electric Fan coil application guide PswrdSet 0 is factory set, range is: 0-1000 BI1 BI2 UI3 enuscro Autoode C or F As per user. Default value = F % disp ockout As per user. Default value = 0 No lock Pipe No 4.0 SeqOpera 4 = Cooling / eating 4 pipes Fan enu 2 DumiCK % set As per user. Default value = 50%. ange = 30% to 95% Dehuyst As per user. Default value = 5%. ange = 2% to 20% DehuCool As per user. Default value = 100%. ange = 20% to 100% St-By T 0.5 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments Unocc T 0.0 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments St-By T 69 F is factory set, range is: 40 to 90 F ( 4.5 to 32.0 C ) St-By C 78 F is factory set, range is: 54 to 100 F ( 12.0 to 37.5 C ) Unocc T As per user. Default value = 62 F ( 17 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) Unocc C As per user. Default value = 80 F ( 27 C ). ange = 54 to 100 F ( 12 to 37.5 C ) heat max As per user. Default value = 90 F ( 32 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) cool min As per user. Default value = 54 F ( 12 C ). ange = 54 to 100 F ( 12 to 37.5 C ) Pband 2 F is factory set, range is: 2 to 10 F ( 0.6 to 5.6 C ) Set Type Permanent SptFunc Dual Stp or AttchStp TOccTime As per user. Default value 2 hours. ange = 0 to 24 hours DoorTime N/A deadband As per user. Default value 2.0 F ( 1.0 C ). ange = 2, 3, 4 or 5 F, 1.0 F increments ( 1.0 to 2.5 C, 0.5 C increments ) cal S 0 F or C cal 0 F or C aux cont 0 Auto Fan AS or AS AD A/DA everse Acting (A) or Direct Acting (DA), depends on actuator eheat 0 for /OFF ( 4CP ), 1 for PW ( 10 second ) UI3 dis Displays supply air temperature

Sequence of operation and wiring Occupied ode: occupied cooling and heating. The changeover sensor will send the supply air temperature to the controller. Stand-by ode (only available when PI motion detector cover is used): standby cooling and heating. Unoccupied ode: unoccupied heating and cooling. Occupied Override ode: The system will revert to occupied mode for the duration determined by the ToccTime parameter. On a call for cool: Cooling valve will modulate to maintain room temperature. eating valve is closed. Dehumidification is enabled. On a call for heat: eating valve will modulate to maintain room temperature. Cooling valve is closed. Dehumidification is disabled. SE7350F Controller CO - - - AO1 AO2 0-10 VDC EATING /OFF Sequence: 0-10 VDC Fan coil relay control center (Generic) COOING AC - 230VAC 120V To Fan Coil Unit On a demand for dehumidification: Dehumidification is achieved via the cooling coil using the heating coil for reheat if necessary. Dehumidification is only allowed in COO mode (or if cooling is enabled in AUTO mode). ysterisys = 10% (adjustable) 1/2 ysterisys = 5% 1/2 ysterisys = 5% Dehumidification = Dehumidification is disabled if the room temperature falls below the low ambient lockout temperature. Which is the cooling setpoint minus the configuration defined deadband value. eheat is disabled if PI cooling demand reaches 100%. OFF Dehumidification = OFF % Setpoint Options BACnet, Echelon and Wireless communication models available (see Appendix B for network wiring). emote wall mount or duct sensor ready. Can be configured for 2 pipe systems. Binary inputs can be configured to control occupancy via door or window contact, remote night setback or to provide alarms for service or filter monitoring. Universal input can be configured for a changeover sensor. www.schneider-electric.com 17

SE7355C5045: eating/cooling: 4-pipe fan coil unit with 3-speed fan, 2-position valves, and dehumidification sequence Cooling Coil eating Coil 2-Position Cooling Valve 2-Position eating Valve Optional PI cover: COV-PI-FCU--5045. efer to Schneider Electric Catalogue for valves and actuators. Configuration parameter name SE7355C Configuration settings 18 Schneider Electric Fan coil application guide PswrdSet 0 is factory set, range is: 0-1000 BI1 BI2 UI3 enuscro Autoode C or F As per user. Default value = F % disp ockout As per user. Default value = 0 No lock Pipe No 4.0 CntrlTyp On/Off SeqOpera 4 = Cooling / eating 4 pipes Fan enu 2 DumiCK % set As per user. Default value = 50%. ange = 30% to 95% Dehuyst As per user. Default value = 5%. ange = 2% to 20% DehuCool As per user. Default value = 100%. ange = 20% to 100% St-By T 0.5 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments Unocc T 0.0 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments St-By T 69 F is factory set, range is: 40 to 90 F ( 4.5 to 32.0 C ) St-By C 78 F is factory set, range is: 54 to 100 F ( 12.0 to 37.5 C ) Unocc T As per user. Default value = 62 F ( 17 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) Unocc C As per user. Default value = 80 F ( 27 C ). ange = 54 to 100 F ( 12 to 37.5 C ) heat max As per user. Default value = 90 F ( 32 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) cool min As per user. Default value = 54 F ( 12 C ). ange = 54 to 100 F ( 12 to 37.5 C ) Pband 2 F is factory set, range is: 2 to 10 F ( 0.6 to 5.6 C ) Set Type Permanent SptFunc Dual Stp or AttchStp TOccTime As per user. Default value 2 hours. ange = 0 to 24 hours DoorTime N/A deadband As per user. Default value 2.0 F ( 1.0 C ). ange = 2, 3, 4 or 5 F, 1.0 F increments ( 1.0 to 2.5 C, 0.5 C increments ) cal S 0 F or C cal 0 F or C aux cont 0 Auto Fan AS or AS AD F time As per user. Default value = 1.5 minutes. ange 0.5 to 9.0 in 0.5 minutes increments cph As per user. 4 to 8 CP eheat 0 for /OFF ( 4CP ), 1 for PW ( 10 second ) UI3 dis Displays supply air temperature

Sequence of operation and wiring Occupied ode: occupied cooling and heating. Stand-by ode (only available when PI motion detector cover is used): standby cooling and heating. Unoccupied ode: unoccupied heating and cooling. Occupied Override ode: The system will revert to occupied mode for the duration determined by the ToccTime parameter. On a call for cool: Cooling valve will open to maintain room temperature. eating valve is closed. Dehumidification is enabled. On a call for heat: eating valve will open to maintain room temperature. Cooling valve is closed. Dehumidification is disabled. On a demand for dehumidification: Dehumidification is achieved via the cooling coil using the heating coil for reheat if necessary. Dehumidification is only allowed in COO mode (or if cooling is enabled in AUTO mode). Dehumidification is disabled if the room temperature falls below the low ambient lockout temperature, which is the cooling setpoint minus the configuration defined deadband value. SE7355C Controller CO - - - BO2 BO3 OFF EATING Dehumidification /OFF Sequence: ysterisys = 10% (adjustable) 1/2 ysterisys = 5% 1/2 ysterisys = 5% Dehumidification = Dehumidification = OFF % Setpoint Fan coil relay control center (Generic) COOING AC - 230VAC 120V To Fan Coil Unit Options BACnet, Echelon and Wireless communication models available (see Appendix B for network wiring). odels available with factory installed PI cover. emote wall mount or duct sensor ready / Can be configured for 2 pipe systems. Analogue outputs available (SE73xxF5045). Binary inputs can be configured to control occupancy via door or window contact, remote night setback or to provide alarms for service or filter monitoring / Universal input can be configured for a changeover sensor. www.schneider-electric.com 19

SE7300C5045: Cooling only: 2-pipe fan coil unit with single speed fan, 2-Position cooling valve and fresh air damper Cooling Coil Fresh Air eturn Air 2-Position Cooling Valve Optional PI cover: COV-PI-FCU-C-5045. SE7300C efer to Schneider Electric Catalogue for valves and actuators. Configuration parameter name Configuration settings 20 Schneider Electric Fan coil application guide PswrdSet 0 is factory set, range is: 0-1000 BI1 BI2 UI3 enuscro Autoode C or F As per user. Default value = F ockout As per user. Default value = 0 No lock Pipe No 2.0 CntrlTyp On/Off SeqOpera 0 = Cooling only Fan enu 4 St-By T 0.5 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments Unocc T 0.0 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments St-By T 69 F is factory set, range is: 40 to 90 F ( 4.5 to 32.0 C ) St-By C 78 F is factory set, range is: 54 to 100 F ( 12.0 to 37.5 C ) Unocc T As per user. Default value = 62 F ( 17 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) Unocc C As per user. Default value = 80 F ( 27 C ). ange = 54 to 100 F ( 12 to 37.5 C ) heat max As per user. Default value = 90 F ( 32 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) cool min As per user. Default value = 54 F ( 12 C ). ange = 54 to 100 F ( 12 to 37.5 C ) Pband 2 F is factory set, range is: 2 to 10 F ( 0.6 to 5.6 C ) Set Type Permanent SptFunc Dual Stp or AttchStp TOccTime As per user. Default value 2 hours. ange = 0 to 24 hours DoorTime N/A deadband As per user. Default value 2.0 F ( 1.0 C ). ange = 2, 3, 4 or 5 F, 1.0 F increments ( 1.0 to 2.5 C, 0.5 C increments ) cal S 0 F or C cal 0 F or C aux cont 1 (occupied=contact closed, unoccupied=contact open) Auto Fan AS or AS AD F time As per user. Default value = 1.5 minutes. ange 0.5 to 9.0 in 0.5 minutes increments cph N/A eheat Not used UI3 dis Displays supply air temperature

Sequence of operation and wiring Occupied ode: occupied cooling and heating. The auxiliary contact will close setting the fresh air damper to its minimum position. Stand-by ode (only available when PI motion detector cover is used): standby cooling and heating. Unoccupied ode: unoccupied heating and cooling. The auxiliary contact will open causing the fresh air damper to close completely. Occupied Override ode: The system will revert to occupied mode for the duration determined by the ToccTime parameter. The auxiliary contact will close setting the fresh air damper to its minimum position. On a call for cool: Cooling valve will open. On a call for heat: Cooling valve will close. Options SE7300C Controller CO - - - BO2 Seperate Transformer BO5 BO5 CO AC Actuator Fresh air AC Transformer CO AC COOING BACnet, Echelon and Wireless models available (see Appendix B for network wiring). Analogue 0-10 VDC outputs available (SE73xxF5045). emote wall mount or duct sensor ready. Can be configured for 4 pipe systems. Binary inputs can be configured to control occupancy via door or window contact, remote night setback or to provide alarms for service or filter monitoring. Can be configured for two speed or three speed fan control. www.schneider-electric.com 21

SE7300F5045: heating/cooling with changeover sensor and reheat: 2-pipe fan coil unit with 3-speed fan, analogue valve, and electric reheat eating/cooling Coil Analogue Valve Sensor: 10K Ohm Type 2. Optional PI cover: COV-PI-FCU-C-5045. efer to Schneider Electric Catalogue for valves and actuators. SE7300F Configuration parameter name Configuration settings 22 Schneider Electric Fan coil application guide PswrdSet 0 is factory set, range is: 0-1000 BI1 BI2 UI3 COS enuscro Autoode C or F As per user. Default value = F ockout As per user. Default value = 0 No lock Pipe No 2.0 SeqOpera 2 = Cooling with eheat Fan enu 2 St-By T 0.5 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments Unocc T 0.0 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments St-By T 69 F is factory set, range is: 40 to 90 F ( 4.5 to 32.0 C ) St-By C 78 F is factory set, range is: 54 to 100 F ( 12.0 to 37.5 C ) Unocc T As per user. Default value = 62 F ( 17 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) Unocc C As per user. Default value = 80 F ( 27 C ). ange = 54 to 100 F ( 12 to 37.5 C ) heat max As per user. Default value = 90 F ( 32 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) cool min As per user. Default value = 54 F ( 12 C ). ange = 54 to 100 F ( 12 to 37.5 C ) Pband 2 F is factory set, range is: 2 to 10 F ( 0.6 to 5.6 C ) Set Type Permanent SptFunc Dual Stp or AttchStp TOccTime As per user. Default value 2 hours. ange = 0 to 24 hours DoorTime N/A deadband As per user. Default value 2.0 F ( 1.0 C ). ange = 2, 3, 4 or 5 F, 1.0 F increments ( 1.0 to 2.5 C, 0.5 C increments ) cal S 0 F or C cal 0 F or C aux cont 0 Auto Fan AS or AS AD A/DA As per Valve eheat 0 for /OFF ( 4CP ), 1 for PW ( 10 second ) only if using SS UI3 dis Displays supply air temperature

Sequence of operation and wiring Occupied ode: SE7300F Controller occupied cooling and heating. The changeover sensor will send the supply air temperature to the controller. BO5 BO5 Permiter eating Fan coil relay control center (Generic) Stand-by ode (only available when PI motion detector cover is used): standby cooling and heating. ac CO - AC - 230VAC 120V Unoccupied ode: unoccupied heating and cooling. Occupied Override ode: - - The system will revert to occupied mode for the duration determined by the ToccTime parameter. A01 SCO To Fan Coil Unit On a call for cool: If water s temperature is less than 24 C (75 F), valve will open to allow water flow. If supply air temperature is greater than 25 C (77 F), valve will close. Baseboard is always desactivated. UI3 C/O Sensor 0-10 Vdc actuator eat/cool valve On a call for heat: If water temperature is less than 24 C (75 F), valve will close and the baseboard will be activated. If water temperature is greater than 25 C (77 F), valve will open to allow water flow. If the water flow is unable to satisfy the demand, the baseboard is activated. Options BACnet, Echelon and Wireless models available (see Appendix B for network wiring). Tri-State Floating outputs available (SE73xxC5045). emote wall mount or duct sensor ready. Can be configured for 4 pipe systems. Binary inputs can be configured to control occupancy via door or window contact, remote night setback or to provide alarms for service or filter monitoring. Can be configured to single or two speed fan. www.schneider-electric.com 23

SE7300F5045: Cooling with reheat: 4-pipe fan coil unit with 3-speed fan, analogue cooling valve and on/off heating valve Cooling Coil eating Coil Analogue Cooling Valve 2-Position eating Valve Optional PI cover: COV-PI-FCU-C-5045. efer to Schneider Electric Catalogue for valves and actuators. SE7300F Configuration parameter name Configuration settings PswrdSet 0 is factory set, range is: 0-1000 BI1 BI2 UI3 enuscro Autoode C or F As per user. Default value = F ockout As per user. Default value = 0 No lock Pipe No 4.0 SeqOpera 2 = Cooling with eheat Fan enu 2 St-By T 0.5 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments Unocc T 0.0 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments St-By T 69 F is factory set, range is: 40 to 90 F ( 4.5 to 32.0 C ) St-By C 78 F is factory set, range is: 54 to 100 F ( 12.0 to 37.5 C ) Unocc T As per user. Default value = 62 F ( 17 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) Unocc C As per user. Default value = 80 F ( 27 C ). ange = 54 to 100 F ( 12 to 37.5 C ) heat max As per user. Default value = 90 F ( 32 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) cool min As per user. Default value = 54 F ( 12 C ). ange = 54 to 100 F ( 12 to 37.5 C ) Pband 2 F is factory set, range is: 2 to 10 F ( 0.6 to 5.6 C ) Set Type Permanent SptFunc Dual Stp or AttchStp TOccTime As per user. Default value 2 hours. ange = 0 to 24 hours DoorTime N/A deadband As per user. Default value 2.0 F ( 1.0 C ). ange = 2, 3, 4 or 5 F, 1.0 F increments ( 1.0 to 2.5 C, 0.5 C increments ) cal S 0 F or C cal 0 F or C aux cont 0 Auto Fan AS or AS AD A/DA As per Valve eheat 0 for /OFF ( 4CP ), 1 for PW ( 10 second ) only if using SS UI3 dis Displays supply air temperature 24 Schneider Electric Fan coil application guide

Sequence of operation and wiring Occupied ode: occupied cooling and heating. Stand-by ode (only available when PI motion detector cover is used): stand-by cooling and heating. Unoccupied ode: unoccupied heating and cooling. Occupied Override ode: The system will revert to occupied mode for the duration determined by the ToccTime parameter. On a call for cool: The Analogue valve will start modulating based on the cooling demand. On a call for heat: The heating valve will open. SE7300F Controller Tranformer 24 VAC-- 230 VAC 120V 120V FCU SPDT 1 igh speed SPDT 2 edium speed SPDT 3 ow speed AO1 0-10V A + A - ( + ) ( - ) Analog 0-10 VDC Cooling Valve BO5 SPDT 4 BO5 eat eat V On/Off eating valve Options BACnet, Echelon and Wireless models available (see Appendix B for network wiring). Tri-State Floating outputs available (SE73xxF5045). emote wall mount or duct sensor ready. Can be configured for 2 pipe systems / Can be configured to single or two speed fan. Binary inputs can be configured to control occupancy via door or window contact, remote night setback or to provide alarms for service or filter monitoring. www.schneider-electric.com 25

SE7300F5045: Cooling only: 2-pipe fan coil unit with 3-speed fan and 0-10 VDC analogue cooling valve Cooling Coil Analogue Cooling Valve Optional PI cover: COV-PI-FCU-C-5045. SE7300F efer to Schneider Electric Catalogue for valves and actuators. Configuration parameter name Configuration settings PswrdSet 0 is factory set, range is: 0-1000 BI1 BI2 UI3 COS enuscro Autoode C or F As per user. Default value = F ockout As per user. Default value = 0 No lock Pipe No 2.0 SeqOpera 0 = Cooling Only Fan enu 4 St-By T 0.5 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments Unocc T 0.0 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments St-By T 69 F is factory set, range is: 40 to 90 F ( 4.5 to 32.0 C ) St-By C 78 F is factory set, range is: 54 to 100 F ( 12.0 to 37.5 C ) Unocc T As per user. Default value = 62 F ( 17 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) Unocc C As per user. Default value = 80 F ( 27 C ). ange = 54 to 100 F ( 12 to 37.5 C ) heat max As per user. Default value = 90 F ( 32 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) cool min As per user. Default value = 54 F ( 12 C ). ange = 54 to 100 F ( 12 to 37.5 C ) Pband 2 F is factory set, range is: 2 to 10 F ( 0.6 to 5.6 C ) Set Type Permanent SptFunc Dual Stp or AttchStp TOccTime As per user. Default value 2 hours. ange = 0 to 24 hours DoorTime N/A deadband As per user. Default value 2.0 F ( 1.0 C ). ange = 2, 3, 4 or 5 F, 1.0 F increments ( 1.0 to 2.5 C, 0.5 C increments ) cal S 0 F or C cal 0 F or C aux cont 0 Auto Fan AS or AS AD cph N/A A/DA As per Valve eheat 0 for /OFF ( 4CP ), 1 for PW ( 10 second ) only if using SS UI3 dis Displays supply air temperature 26 Schneider Electric Fan coil application guide

Sequence of operation and wiring Occupied ode: SE7300F Controller occupied cooling and heating. BO5 Stand-by ode (only available when PI motion detector cover is used): standby cooling and heating. Unoccupied ode: BO5 ac CO Fan coil relay control center (Generic) AC - 230VAC 120V unoccupied heating and cooling. Occupied Override ode: - - The system will revert to occupied mode for the duration determined by the ToccTime parameter. - A01 On a call for cool: Analogue valve will modulate allowing cool air to flow to reach the setpoint. On a call for heat: SCO UI3 0-10 Vdc COOING To Fan Coil Unit Valve will close Options BACnet, Echelon and Wireless models available (see Appendix B for network wiring). emote wall mount or duct sensor ready. Tri-State Floating outputs available (SE73xxC5045) Can be configured for 4 pipe systems. Binary inputs can be configured to control occupancy via door or window contact, remote night setback or to provide alarms for service or filter monitoring. Can be configured to two or three speed fan. www.schneider-electric.com 27

SE7300C5045: Cooling with reheat: 2-pipe fan coil unit with 3-speed fan, 2-position valve and electric reheat Cooling Coil On/Off Duct eater 2-Position Cooling Valve Optional PI cover: COV-PI-FCU-C-5045. SE7300C efer to Schneider Electric Catalogue for valves and actuators. Configuration parameter name Configuration settings 28 Schneider Electric Fan coil application guide PswrdSet 0 is factory set, range is: 0-1000 BI1 BI2 UI3 enuscro Autoode C or F As per user. Default value = F ockout As per user. Default value = 0 No lock Pipe No 2.0 CntrlTyp On/Off SeqOpera 2 = Cooling with eheat Fan enu 2 St-By T 0.5 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments Unocc T 0.0 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments St-By T 69 F is factory set, range is: 40 to 90 F ( 4.5 to 32.0 C ) St-By C 78 F is factory set, range is: 54 to 100 F ( 12.0 to 37.5 C ) Unocc T As per user. Default value = 62 F ( 17 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) Unocc C As per user. Default value = 80 F ( 27 C ). ange = 54 to 100 F ( 12 to 37.5 C ) heat max As per user. Default value = 90 F ( 32 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) cool min As per user. Default value = 54 F ( 12 C ). ange = 54 to 100 F ( 12 to 37.5 C ) Pband 2 F is factory set, range is: 2 to 10 F ( 0.6 to 5.6 C ) Set Type Permanent SptFunc Dual Stp or AttchStp TOccTime As per user. Default value 2 hours. ange = 0 to 24 hours DoorTime N/A deadband As per user. Default value 2.0 F ( 1.0 C ). ange = 2, 3, 4 or 5 F, 1.0 F increments ( 1.0 to 2.5 C, 0.5 C increments ) cal S 0 F or C cal 0 F or C aux cont 0 Auto Fan AS or AS AD F time As per user. Default value = 1.5 minutes. ange 0.5 to 9.0 in 0.5 minutes increments cph N/A eheat 0 for /OFF ( 4CP ), 1 for PW ( 10 second ) UI3 dis Displays supply air temperature

Sequence of operation and wiring Occupied ode: SE7300C Controller occupied cooling and heating. The changeover sensor will send the supply air temperature to the controller. Stand-by ode (only available when PI motion detector cover is used): standby cooling and heating. Unoccupied ode: unoccupied heating and cooling. Occupied Override ode: BO5 BO5 CO - - - BO1 Perimeter eating Fan coil relay control center (Generic) AC - 230VAC 120V The system will revert to occupied mode for the duration determined by the ToccTime parameter. BO2 To Fan Coil Unit On a call for cool: Cooling valve will open. Electric heat will stay Off. On a call for heat: Valve will close. Electric heat will be activated. AC actuator Options Cooling valve BACnet, Echelon and Wireless models available (see Appendix B for network wiring). Analogue 0-10 VDC outputs available (SE73xxF5045). emote wall mount or duct sensor ready. Can be configured for 4 pipe systems. Binary inputs can be configured to control occupancy via door or window contact, remote night setback or to provide alarms for service or filter monitoring. Can be configured to single or two speed fan. www.schneider-electric.com 29

SE7350F5045: eating/cooling: 4-pipe fan coil unit with 3-speed fan, 0-10 VDC analogue valves and dehumidification sequence Cooling Coil eating Coil Analogue Cooling Valve Analogue eating Valve Optional PI cover: COV-PI-FCU-C-5045. efer to Schneider Electric Catalogue for valves and actuators. SE7350F Configuration parameter name Configuration settings 30 Schneider Electric Fan coil application guide PswrdSet 0 is factory set, range is: 0-1000 BI1 BI2 UI3 enuscro Autoode C or F As per user. Default value = F % disp ockout As per user. Default value = 0 No lock Pipe No 4.0 SeqOpera 4 = Cooling / eating 4 pipes Fan enu 2 DumiCK % set As per user. Default value = 50%. ange = 30% to 95% Dehuyst As per user. Default value = 5%. ange = 2% to 20% DehuCool As per user. Default value = 100%. ange = 20% to 100% St-By T 0.5 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments Unocc T 0.0 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments St-By T 69 F is factory set, range is: 40 to 90 F ( 4.5 to 32.0 C ) St-By C 78 F is factory set, range is: 54 to 100 F ( 12.0 to 37.5 C ) Unocc T As per user. Default value = 62 F ( 17 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) Unocc C As per user. Default value = 80 F ( 27 C ). ange = 54 to 100 F ( 12 to 37.5 C ) heat max As per user. Default value = 90 F ( 32 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) cool min As per user. Default value = 54 F ( 12 C ). ange = 54 to 100 F ( 12 to 37.5 C ) Pband 2 F is factory set, range is: 2 to 10 F ( 0.6 to 5.6 C ) Set Type Permanent SptFunc Dual Stp or AttchStp TOccTime As per user. Default value 2 hours. ange = 0 to 24 hours DoorTime N/A deadband As per user. Default value 2.0 F ( 1.0 C ). ange = 2, 3, 4 or 5 F, 1.0 F increments ( 1.0 to 2.5 C, 0.5 C increments ) cal S 0 F or C cal 0 F or C aux cont 0 Auto Fan AS or AS AD A/DA everse Acting (A) or Direct Acting (DA), depends on actuator eheat 0 for /OFF ( 4CP ), 1 for PW ( 10 second ) UI3 dis Displays supply air temperature

Sequence of operation and wiring Occupied ode: occupied cooling and heating. The changeover sensor will send the supply air temperature to the controller. SE7350F Controller CO Fan coil relay control center (Generic) AC - 230VAC 120V Stand-by ode (only available when PI motion detector cover is used): standby cooling and heating. Unoccupied ode: unoccupied heating and cooling. - - - AO1 AO2 Occupied Override ode: To Fan Coil Unit The system will revert to occupied mode for the duration determined by the ToccTime parameter. 0-10 VDC EATING 0-10 VDC COOING On a call for cool: Cooling valve will modulate to maintain room temperature. eating valve is closed. Dehumidification is enabled. On a call for heat: eating valve will modulate to maintain room temperature. Cooling valve is closed. Dehumidification is disabled. Dehumidification /OFF sequence: ysterisys = 10% (adjustable) On a demand for dehumidification: Dehumidification is achieved via the cooling coil using the heating coil for reheat if necessary. 1/2 ysterisys = 5% 1/2 ysterisys = 5% Dehumidification = Dehumidification is only allowed in COO mode (or if cooling is enabled in AUTO mode). Dehumidification is disabled if the room temperature falls below the low ambient lockout temperature. Which is the cooling setpoint minus the configuration defined deadband value. OFF Dehumidification = OFF % Setpoint eheat is disabled if PI cooling demand reaches 100%. Options BACnet, Echelon and Wireless communication models available (see Appendix B for network wiring). emote wall mount or duct sensor ready. Can be configured for 2 pipe systems (with changeover). Binary inputs can be configured to control occupancy via door or window contact, remote night setback or to provide alarms for service or filter monitoring. Universal input can be configured for a changeover sensor. www.schneider-electric.com 31

SE7350C5045: eating/cooling: 4-pipe fan coil unit with 3-speed fan, 2-position valves, and dehumidification sequence Cooling Coil eating Coil 2-Position Cooling Valve 2-Position eating Valve Optional PI cover: COV-PI-FCU-C-5045. efer to Schneider Electric Catalogue for valves and actuators. Configuration parameter name 32 Schneider Electric Fan coil application guide SE7350C Configuration settings PswrdSet 0 is factory set, range is: 0-1000 BI1 BI2 UI3 enuscro Autoode C or F As per user. Default value = F % disp ockout As per user. Default value = 0 No lock Pipe No 4.0 CntrlTyp On/Off SeqOpera 4 = Cooling / eating 4 pipes Fan enu 2 DumiCK % set As per user. Default value = 50%. ange = 30% to 95% Dehuyst As per user. Default value = 5%. ange = 2% to 20% DehuCool As per user. Default value = 100%. ange = 20% to 100% St-By T 0.5 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments Unocc T 0.0 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments St-By T 69 F is factory set, range is: 40 to 90 F ( 4.5 to 32.0 C ) St-By C 78 F is factory set, range is: 54 to 100 F ( 12.0 to 37.5 C ) Unocc T As per user. Default value = 62 F ( 17 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) Unocc C As per user. Default value = 80 F ( 27 C ). ange = 54 to 100 F ( 12 to 37.5 C ) heat max As per user. Default value = 90 F ( 32 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) cool min As per user. Default value = 54 F ( 12 C ). ange = 54 to 100 F ( 12 to 37.5 C ) Pband 2 F is factory set, range is: 2 to 10 F ( 0.6 to 5.6 C ) Set Type Permanent SptFunc Dual Stp or AttchStp TOccTime As per user. Default value 2 hours. ange = 0 to 24 hours DoorTime N/A deadband As per user. Default value 2.0 F ( 1.0 C ). ange = 2, 3, 4 or 5 F, 1.0 F increments ( 1.0 to 2.5 C, 0.5 C increments ) cal S 0 F or C cal 0 F or C aux cont 0 Auto Fan AS or AS AD F time As per user. Default value = 1.5 minutes. ange 0.5 to 9.0 in 0.5 minutes increments cph As per user. 4 to 8 CP eheat 0 for /OFF ( 4CP ), 1 for PW ( 10 second ) UI3 dis Displays supply air temperature

Sequence of operation and wiring Occupied ode: occupied cooling and heating. Stand-by ode (only available when PI motion detector cover is used): standby cooling and heating. Unoccupied ode: unoccupied heating and cooling. Occupied Override ode: The system will revert to occupied mode for the duration determined by the ToccTime parameter. On a call for cool: Cooling valve will open to maintain room temperature. eating valve is closed. Dehumidification is enabled. On a call for heat: eating valve will open to maintain room temperature. Cooling valve is closed. Dehumidification is disabled. On a demand for dehumidification: Dehumidification is achieved via the cooling coil using the heating coil for reheat if necessary. Dehumidification is only allowed in COO mode (or if cooling is enabled in AUTO mode). Dehumidification is disabled if the room temperature falls below the low ambient lockout temperature, which is the cooling setpoint minus the configuration defined deadband value. SE7350C Controller CO - - - BO2 BO3 OFF EATING Dehumidification /OFF Sequence: ysterisys = 10% (adjustable) 1/2 ysterisys = 5% 1/2 ysterisys = 5% Dehumidification = Dehumidification = OFF % Setpoint Fan coil relay control center (Generic) COOING AC - 230VAC 120V To Fan Coil Unit Options BACnet, Echelon and Wireless communication models available (see Appendix B for network wiring). emote wall mount or duct sensor ready. Can be configured for 2 pipe systems (with changeover). Analogue outputs available (SE73xxF5045). Binary inputs can be configured to control occupancy via door or window contact, remote night setback or to provide alarms for service or filter monitoring / Universal input can be configured for a changeover sensor. www.schneider-electric.com 33

SE7350C5045: eating/cooling: 4-pipe fan coil unit with 3-speed fan, tri-state floating valves and dehumidification sequence Cooling Coil eating Coil Tri-state Floating Valve Tri-state Floating Valve Optional PI cover: COV-PI-FCU-C-5045. efer to Schneider Electric Catalogue for valves and actuators. Configuration parameter name SE7350C Configuration settings 34 Schneider Electric Fan coil application guide PswrdSet 0 is factory set, range is: 0-1000 BI1 BI2 UI3 enuscro Autoode C or F As per user. Default value = F % disp ockout As per user. Default value = 0 No lock Pipe No 4.0 CntrlTyp Floating SeqOpera 4 = Cooling / eating 4 pipes Fan enu 2 DumiCK % set As per user. Default value = 50%. ange = 30% to 95% Dehuyst As per user. Default value = 5%. ange = 2% to 20% DehuCool As per user. Default value = 100%. ange = 20% to 100% St-By T 0.5 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments Unocc T 0.0 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments St-By T 69 F is factory set, range is: 40 to 90 F ( 4.5 to 32.0 C ) St-By C 78 F is factory set, range is: 54 to 100 F ( 12.0 to 37.5 C ) Unocc T As per user. Default value = 62 F ( 17 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) Unocc C As per user. Default value = 80 F ( 27 C ). ange = 54 to 100 F ( 12 to 37.5 C ) heat max As per user. Default value = 90 F ( 32 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) cool min As per user. Default value = 54 F ( 12 C ). ange = 54 to 100 F ( 12 to 37.5 C ) Pband 2 F is factory set, range is: 2 to 10 F ( 0.6 to 5.6 C ) Set Type Permanent SptFunc Dual Stp or AttchStp TOccTime As per user. Default value 2 hours. ange = 0 to 24 hours DoorTime N/A deadband As per user. Default value 2.0 F ( 1.0 C ). ange = 2, 3, 4 or 5 F, 1.0 F increments ( 1.0 to 2.5 C, 0.5 C increments ) cal S 0 F or C cal 0 F or C aux cont 0 Auto Fan AS or AS AD F time As per user. Default value = 1.5 minutes. ange 0.5 to 9.0 in 0.5 minutes increments cph N/A eheat 0 for /OFF ( 4CP ), 1 for PW ( 10 second ) UI3 dis Displays supply air temperature

Sequence of operation and wiring Occupied ode: occupied cooling and heating. The changeover sensor will send the supply air temperature to the controller. SE7350C Controller CO Fan coil relay control center (Generic) AC - 230VAC 120V Stand-by ode (only available when PI motion detector cover is used): standby cooling and heating. - - - Unoccupied ode: unoccupied heating and cooling. BO1 BO2 Occupied Override ode: The system will revert to occupied mode for the duration determined by the ToccTime parameter. BO3 BO4 To Fan Coil Unit On a call for cool: Cooling valve will modulate to maintain room temperature. eating valve is closed. Dehumidification is enabled. Close Open EATING Close Open COOING On a call for heat: eating valve will modulate to maintain room temperature. Cooling valve is closed. Dehumidification is disabled. Dehumidification /OFF Sequence: On a demand for dehumidification: Dehumidification is achieved via the cooling coil using the heating coil for reheat if necessary. ysterisys = 10% (adjustable) 1/2 ysterisys = 5% 1/2 ysterisys = 5% Dehumidification is only allowed in COO mode (or if cooling is enabled in AUTO mode). Dehumidification = Dehumidification is disabled if the room temperature falls below the low ambient lockout temperature. Which is the cooling setpoint minus the configuration defined deadband value. OFF Dehumidification = OFF % Setpoint eheat is disabled if cooling demand reaches 100%. Options BACnet, Echelon and Wireless communication models available (see Appendix B for network wiring). emote wall mount or duct sensor ready. Analogue outputs available (SE73xxF5045). Can be configured for 2 pipe systems (with changeover). Binary inputs can be configured to control occupancy via door or window contact, remote night setback or to provide alarms for service or filter monitoring. Universal input can be configured for a changeover sensor. www.schneider-electric.com 35

1 Tx / x 2 7 Vdc Power Supply 3 SC3500E5045 008-0566 WITE 90-277 Vac - 50/60 z 1/2P + 5A b. Amb. Temp. 50 o C BACK ED OW 1/2 P BUE ED BOWN IG 5A COO YEOW OANGE EAT OANGE 90-277 Vac 10A Amb. Temp. 50 o C STATUS Use copper conductors ade in Canada 75 oc min. only. SE7300A5045 - SC3500E5045: eating/cooling: 4-pipe fan coil unit with 3-speed fan, 2-position valves with wireless door switch Cooling Coil eating Coil 2-Position Cooling Valve 2-Position eating Valve VWA5000D5045W Optional PI cover: COV-PI-FCU-C-5045. SE7300A Configuration parameter name SC3500E Configuration settings Door Switch: VWA5045D5045W. efer to Schneider Electric Catalogue for valves and actuators. 36 Schneider Electric Fan coil application guide PswrdSet 0 is factory set, range is: 0-1000 BI1 Door BI2 UI1 BI2 enuscro Autoode C or F As per user. Default value = F % disp OFF ockout As per user. Default value = 0 No lock Pulsedt OFF Pipe No 4.0 SeqOpera 2 = Cooling / eating 4 pipes Fan enu 2 DumiCK % set As per user. Default value = 50%. ange = 30% to 95% Dehuyst As per user. Default value = 5%. ange = 2% to 20% DehuCool As per user. Default value = 100%. ange = 20% to 100% St-By T 0.5 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments Unocc T 0.0 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments St-By T 69 F is factory set, range is: 40 to 90 F ( 4.5 to 32.0 C ) St-By C 78 F is factory set, range is: 54 to 100 F ( 12.0 to 37.5 C ) Unocc T As per user. Default value = 62 F ( 17 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) Unocc C As per user. Default value = 80 F ( 27 C ). ange = 54 to 100 F ( 12 to 37.5 C ) heat max As per user. Default value = 90 F ( 32 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) cool min As per user. Default value = 54 F ( 12 C ). ange = 54 to 100 F ( 12 to 37.5 C ) Pband 3 F is factory set, range is: 2 to 10 F ( 0.6 to 5.6 C ) Set Type Permanent SptFunc Dual Stp or AttchStp TOccTime As per user. Default value 2 hours. ange = 0 to 24 hours deadband As per user. Default value 2.0 F ( 1.0 C ). cal S 0 F or C cal 0 F or C Auto Fan AS or AS AD Cool cph As per user. 4 to 8 CP eat cph As per user. 4 to 8 CP CoolNoNc NC eatnonc NC Fan Cont

Tx / x 7 Vdc Power Supply 008-0566 WITE 90-277 Vac - 50/60 z 1/2P + 5A b. Amb. Temp. 50 o C BACK ED OW 1/2 P BUE ED BOWN IG 5A COO YEOW OANGE EAT OANGE 90-277 Vac 10A Amb. Temp. 50 o C STATUS Use copper conductors 75 o C min. only. ade in Canada Sequence of operation and wiring Occupied ode: occupied cooling and heating. Stand-by ode (only available when PI motion detector cover is used): stand-by cooling and heating. Unoccupied ode: unoccupied heating and cooling. Occupied Override ode: The system will revert to occupied mode for the duration determined by the ToccTime parameter. On a call for cool: Cooling valve will open to maintain room temperature. eating valve is closed. On a call for heat: eating valve will open to maintain room temperature. Cooling valve is closed. Wireless Door Switch: The wireless door switch will automatically toggle occupancy. See page 48 for more details. SE7300A Controller 1 2 3 SC3500E Tx-x 7 VDC CO BI1 SCO SC3500E5045 BI2 SC3500E elay Pack Tx/x 7 VDC CO To Fan Coil Unit (igh Voltage Side) Typical Wiring Example for SC elay Pack Brown - igh Speed Blue - edium Speed ed - ow Speed Orange - eating Valve Yellow - Cooling Valve V V Black - ive Power Orange - Connected to Black-ive Power White - Neutral For 2 pipe applications use cooling valave yellow wire connection For electric reheat applications wher ecurrent draw is under above 10A use a line powered coil pilot duty relay contactor for the heating element in place of the heating valve. Options BACnet and Wireless communication models available (see Appendix B for network wiring). emote wall mount or duct sensor ready. Can be configured for 2 pipe systems (with changeover). Binary inputs can be configured to control occupancy via door or window contact, remote night setback or to provide alarms for service or filter monitoring / Universal input can be configured for a changeover sensor. www.schneider-electric.com 37

1 Tx / x 2 7 Vdc 3 4 UI 1 5 S 6 BI 2 7 SS 8 S 9 eat- 1/2 P ED 10 eat+ IG 5A COO STATUS Use copper conductors 75 o C min. only. Power Supply SC3404E5045 008-0565 WITE 90-277 Vac - 50/60 z 1/2P + 5A b. Amb. Temp. 50 o C BACK OW ED BUE BOWN YEOW ade in Canada SE7350A5045 - SC3404E5045: Cooling and electric heat: 2-pipe fan coil unit with 3-speed fan, dehumidification, 2-position valves Cooling Coil Electric eat Optional PI cover: COV-PI-FCU-C-5045. SE7350A SC3404E SS SS: Solid State elay (Generic) efer to Schneider Electric Catalogue for valves and actuators. Configuration parameter name Configuration settings 38 Schneider Electric Fan coil application guide PswrdSet 0 is factory set, range is: 0-1000 BI1 BI2 UI1 BI2 enuscro Autoode C or F As per user. Default value = F % disp ockout As per user. Default value = 0 No lock Pulsedt Pipe No 2.0 SeqOpera 2 = Cooling with eheat Fan enu 2 DumiCK % set As per user. Default value = 50%. ange = 30% to 95% Dehuyst As per user. Default value = 5%. ange = 2% to 20% DehuCool As per user. Default value = 100%. ange = 20% to 100% St-By T 0.5 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments Unocc T 0.0 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments St-By T 69 F is factory set, range is: 40 to 90 F ( 4.5 to 32.0 C ) St-By C 78 F is factory set, range is: 54 to 100 F ( 12.0 to 37.5 C ) Unocc T As per user. Default value = 62 F ( 17 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) Unocc C As per user. Default value = 80 F ( 27 C ). ange = 54 to 100 F ( 12 to 37.5 C ) heat max As per user. Default value = 90 F ( 32 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) cool min As per user. Default value = 54 F ( 12 C ). ange = 54 to 100 F ( 12 to 37.5 C ) Pband 3 F is factory set, range is: 2 to 10 F ( 0.6 to 5.6 C ) Set Type Permanent SptFunc Dual Stp or AttchStp TOccTime As per user. Default value 2 hours. ange = 0 to 24 hours deadband As per user. Default value 2.0 F ( 1.0 C ). cal S 0 F or C cal 0 F or C Auto Fan AS or AS AD Cool cph As per user. 4 to 8 CP eat cph As per user. 4 to 8 CP CoolNoNc NC eatnonc NC Fan Cont

1 Tx / x 2 7 Vdc Power Supply 3 4 UI 1 008-0565 5 S WITE 90-277 Vac - 50/60 z 6 BI 2 1/2P + 5A b. Amb. Temp. 50 o C 7 SS BACK 8 S OW ED 9 eat- 1/2 P ED BUE 10 eat+ IG BOWN 5A COO YEOW STATUS Use copper conductors 75 o C min. only. ade in Canada Sequence of operation and wiring Occupied ode: occupied cooling and heating. Stand-by ode (only available when PI motion detector cover is used): standby cooling and heating. Unoccupied ode: unoccupied heating and cooling. Occupied Override ode: The system will revert to occupied mode for the duration determined by the ToccTime parameter. On a call for cool: Cooling valve will open to maintain room temperature. eating valve is closed. Dehumidification is enabled. On a call for heat: eating valve will open to maintain room temperature. Cooling valve is closed. Dehumidification is disabled. On a demand for dehumidification: Dehumidification is achieved via the cooling coil using the heating coil for reheat if necessary. Dehumidification is only allowed in COO mode (or if cooling is enabled in AUTO mode). Dehumidification is disabled if the room temperature falls below the low ambient lockout temperature, which is the cooling setpoint minus the configuration defined deadband value. Options SE7350A Controller Tx-x 7 VDC CO BI1 SCO BI2 SC3404E SC3404E elay Pack Tx/x 7 VDC CO UI 1 SCO BI 2 SS S eat - eat + To Fan Coil Unit (ight Voltage Side) SS Typical Wiring Example for SC elay Pack SC3404E5045 Brown - igh Speed Blue - edium Speed ed - ow Speed Yellow - Cooling Valve For 2 pipe applications use cooling valave yellow wire connection For electric reheat applications wher ecurrent draw is under above 10A use a line powered coil pilot duty relay contactor for the heating element in place of the heating valve. V Black - ive Power White - Neutral BACnet and Wireless communication models available (see Appendix B for network wiring). emote wall mount or duct sensor ready. Can be configured for 2 pipe systems (with changeover). Binary inputs can be configured to control occupancy via door or window contact, remote night setback or to provide alarms for service or filter monitoring / Universal input can be configured for a changeover sensor. www.schneider-electric.com 39

1 Tx / x 2 7 Vdc Power Supply 3 SC3404E5045 4 UI 1 008-0565 5 S WITE 90-277 Vac - 50/60 z 6 BI 2 1/2P + 5A b. Amb. Temp. 50 o C 7 SS BACK 8 S OW ED 9 eat- 1/2 P ED BUE 10 eat+ IG BOWN 5A COO YEOW STATUS Use copper conductors 75 o C min. only. ade in Canada SE7300A5045 - SC3504E5045: eating/cooling with changeover sensor: 2-pipe fan coil unit with 3-speed fan and wirelesss window switch VWA5000W5045W eating/cooling Coil C/O Sensor Supply Sensor Optional PI cover: COV-PI-FCU-C-5045. Changeover Sensor: 10K Ohm type 2. Supply Sensor: 10K Ohm type 2. Window Switch: VWA5000W5045W. SE7300A SC3504E efer to Schneider Electric Catalogue for valves and actuators. Configuration parameter name Configuration settings 40 Schneider Electric Fan coil application guide PswrdSet 0 is factory set, range is: 0-1000 BI1 Window BI2 UI1 COS BI2 enuscro Autoode C or F As per user. Default value = F % disp OFF ockout As per user. Default value = 0 No lock Pulsedt OFF Pipe No 2.0 SeqOpera 0 = Cooling only Fan enu 2 DumiCK % set As per user. Default value = 50%. ange = 30% to 95% Dehuyst As per user. Default value = 5%. ange = 2% to 20% DehuCool As per user. Default value = 100%. ange = 20% to 100% St-By T 0.5 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments Unocc T 0.0 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments St-By T 69 F is factory set, range is: 40 to 90 F ( 4.5 to 32.0 C ) St-By C 78 F is factory set, range is: 54 to 100 F ( 12.0 to 37.5 C ) Unocc T As per user. Default value = 62 F ( 17 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) Unocc C As per user. Default value = 80 F ( 27 C ). ange = 54 to 100 F ( 12 to 37.5 C ) heat max As per user. Default value = 90 F ( 32 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) cool min As per user. Default value = 54 F ( 12 C ). ange = 54 to 100 F ( 12 to 37.5 C ) Pband 3 F is factory set, range is: 2 to 10 F ( 0.6 to 5.6 C ) Set Type Permanent SptFunc Dual Stp or AttchStp TOccTime As per user. Default value 2 hours. ange = 0 to 24 hours DoorTime N/A deadband As per user. Default value 2.0 F ( 1.0 C ). cal S 0 F or C cal 0 F or C Auto Fan AS or AS AD Cool cph As per user. 4 to 8 CP eat cph As per user. 4 to 8 CP CoolNoNc NC eatnonc NC Fan Cont

1 Tx / x 2 7 Vdc Power Supply 3 4 UI 1 008-0567 5 S WITE 90-277 Vac - 50/60 z 6 BI 2 1/2P + 5A b. Amb. Temp. 50 oc 7 SS BACK 8 S ED OW 1/2 P BUE ED BOWN IG 5A COO YEOW STATUS Use copper conductors 75 oc min. only. EAT OANGE OANGE 90-277 Vac 10A Amb. Temp. 50 oc ade in Canada Sequence of operation and wiring Occupied ode: occupied cooling and heating. Stand-by ode (only available when PI motion detector cover is used): standby cooling and heating. Unoccupied ode: unoccupied heating and cooling. Occupied Override ode: The system will revert to occupied mode for the duration determined by the ToccTime parameter. On a call for cool: If the supply water temperature is less than 24 C (75F), the cooling valve will open to maintain room temperature. eating valve is closed. On a call for heat: If the supply water temperature is greater than 25 C (77F), the heating valve will open to maintain room temperature. Cooling valve is closed. Supply Air Sensor: Only used for monitoring. Will be displayed automatically if sensor is connected. Wireless Window Switch: The wireless window switch will automatically lock out heating/cooling when window is opened. See page 48 for more details. SE7300A Controller Tx-x 7 VDC CO BI1 SCO BI2 SC3504E SC3504 elay Pack Tx/x 7 VDC CO UI 1 SCO BI 2 SS S To Fan Coil Unit (ight Voltage Side) Typical Wiring Example for SC elay Pack SC3504E5045 Brown - igh Speed Blue - edium Speed ed - ow Speed Yellow - Cooling Valve For 2 pipe applications use cooling valave yellow wire connection For electric reheat applications wher ecurrent draw is under above 10A use a line powered coil pilot duty relay contactor for the heating element in place of the heating valve. V Black - ive Power White - Neutral Options BACnet and Wireless communication models available (see Appendix B for network wiring). emote wall mount or duct sensor ready. Can be configured for 2 pipe systems (with changeover). Binary inputs can be configured to control occupancy via door or window contact, remote night setback or to provide alarms for service or filter monitoring / Universal input can be configured for a changeover sensor. www.schneider-electric.com 41

1 Tx / x 2 7 Vdc Power Supply 3 SC3400E5045 008-0564 WITE 90-277 Vac - 50/60 z 1/2P + 5A b. Amb. Temp. 50 oc BACK STATUS Use copper conductors 75 oc min. only. OW 1/2 P ED IG ED BUE BOWN ade in Canada SE7350A5045 - SC3400E5045: Cooling and electric heat: 2-pipe fan coil unit with 3-speed fan and dehumidification, 2-position valves Cooling Coil Electric eater Optional PI cover: COV-PI-FCU-C-5045. SE7350A SC3400E SS SS: Solid State elay (Generic) efer to Schneider Electric Catalogue for valves and actuators. Configuration parameter name Configuration settings 42 Schneider Electric Fan coil application guide PswrdSet 0 is factory set, range is: 0-1000 BI1 BI2 UI1 BI2 enuscro Autoode C or F As per user. Default value = F % disp ockout As per user. Default value = 0 No lock Pulsedt Pipe No 2.0 SeqOpera 2 = Cooling with eheat Fan enu 2 DumiCK % set As per user. Default value = 50%. ange = 30% to 95% Dehuyst As per user. Default value = 5%. ange = 2% to 20% DehuCool As per user. Default value = 100%. ange = 20% to 100% St-By T 0.5 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments Unocc T 0.0 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments St-By T 69 F is factory set, range is: 40 to 90 F ( 4.5 to 32.0 C ) St-By C 78 F is factory set, range is: 54 to 100 F ( 12.0 to 37.5 C ) Unocc T As per user. Default value = 62 F ( 17 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) Unocc C As per user. Default value = 80 F ( 27 C ). ange = 54 to 100 F ( 12 to 37.5 C ) heat max As per user. Default value = 90 F ( 32 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) cool min As per user. Default value = 54 F ( 12 C ). ange = 54 to 100 F ( 12 to 37.5 C ) Pband 3 F is factory set, range is: 2 to 10 F ( 0.6 to 5.6 C ) Set Type Permanent SptFunc Dual Stp or AttchStp TOccTime As per user. Default value 2 hours. ange = 0 to 24 hours deadband As per user. Default value 2.0 F ( 1.0 C ). cal S 0 F or C cal 0 F or C Auto Fan AS or AS AD Cool cph As per user. 4 to 8 CP eat cph As per user. 4 to 8 CP CoolNoNc NC eatnonc NC Fan Cont

1 Tx / x 2 7 Vdc Power Supply 3 SC3400E5045 008-0564 WITE 90-277 Vac - 50/60 z 1/2P + 5A b. Amb. Temp. 50 oc BACK 1/2 P STATUS Use copper conductors 75 oc min. only. OW ED IG ED BUE BOWN ade in Canada Sequence of operation and wiring Occupied ode: occupied cooling and heating. SE7350A Controller Tx-x SC3400E elay Pack Tx/x Stand-by ode (only available when PI motion detector cover is used): 7 VDC 7 VDC To Fan Coil Unit (igh Voltage Side) standby cooling and heating. CO CO Unoccupied ode: unoccupied heating and cooling. BI1 SCO eat - eat + SS Occupied Override ode: BI2 The system will revert to occupied mode for the duration determined by the ToccTime parameter. On a call for cool: Cooling valve will open to maintain room temperature. eating valve is closed. Dehumidification is enabled. On a call for heat: Electric heat will opearate to maintain room temperature. Cooling valve is closed. Dehumidification is disabled. On a demand for dehumidification: Dehumidification is achieved via the cooling coil using the heating coil for reheat if necessary. Dehumidification is only allowed in COO mode (or if cooling is enabled in AUTO mode). Dehumidification is disabled if the room temperature falls below the low ambient lockout temperature, which is the cooling setpoint minus the configuration defined deadband value. SC3400E Typical Wiring Example for SC elay Pack Brown - igh Speed Blue - edium Speed ed - ow Speed Yellow - Cooling Valve For 2 pipe applications use cooling valave yellow wire connection For electric reheat applications wher ecurrent draw is under above 10A use a line powered coil pilot duty relay contactor for the heating element in place of the heating valve. V Black - ive Power White - Neutral Options BACnet and Wireless communication models available (see Appendix B for network wiring). emote wall mount or duct sensor ready. Can be configured for 2 pipe systems (with changeover). Binary inputs can be configured to control occupancy via door or window contact, remote night setback or to provide alarms for service or filter monitoring / Universal input can be configured for a changeover sensor. www.schneider-electric.com 43

1 Tx / x 2 7 Vdc Power Supply 3 SC3514E5045 4 UI 1 008-0568 5 S WITE 90-277 Vac - 50/60 z 6 BI 2 1/2P + 5A b. Amb. Temp. 50 oc 7 SS BACK 8 S OW ED 9 Occ 1/2 P ED BUE 10 IG BOWN 5A COO YEOW OANGE EAT OANGE 90-277 Vac 10A Amb. Temp. 50 oc STATUS Use copper conductors ade in Canada 75 oc min. only. SE7300A5545 - SC3514E5045: eating/cooling: 2-pipe fan coil unit with 3-speed fan and fresh air damper, 2-position valves eating/cooling Coil Fresh Air Supply Sensor eturn Air C/O Sensor Optional PI cover: COV-PI-FCU-C-5045. Supply Sensor: 10K Ohm type 2. SE7300A SC3514E Changeover Sensor: 10K Ohm type 2. efer to Schneider Electric Catalogue for valves and actuators. Configuration parameter name Configuration settings 44 Schneider Electric Fan coil application guide PswrdSet 0 is factory set, range is: 0-1000 BI1 BI2 UI1 COS BI2 enuscro Autoode C or F As per user. Default value = F % disp OFF ockout As per user. Default value = 0 No lock Pulsedt Occ Pipe No 2.0 SeqOpera 0 = Cooling only Fan enu 2 DumiCK % set As per user. Default value = 50%. ange = 30% to 95% Dehuyst As per user. Default value = 5%. ange = 2% to 20% DehuCool As per user. Default value = 100%. ange = 20% to 100% St-By T 0.5 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments Unocc T 0.0 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments St-By T 69 F is factory set, range is: 40 to 90 F ( 4.5 to 32.0 C ) St-By C 78 F is factory set, range is: 54 to 100 F ( 12.0 to 37.5 C ) Unocc T As per user. Default value = 62 F ( 17 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) Unocc C As per user. Default value = 80 F ( 27 C ). ange = 54 to 100 F ( 12 to 37.5 C ) heat max As per user. Default value = 90 F ( 32 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) cool min As per user. Default value = 54 F ( 12 C ). ange = 54 to 100 F ( 12 to 37.5 C ) Pband 3 F is factory set, range is: 2 to 10 F ( 0.6 to 5.6 C ) Set Type Permanent SptFunc Dual Stp or AttchStp TOccTime As per user. Default value 2 hours. ange = 0 to 24 hours DoorTime N/A deadband As per user. Default value 2.0 F ( 1.0 C ). cal S 0 F or C cal 0 F or C Auto Fan AS or AS AD Cool cph As per user. 4 to 8 CP eat cph As per user. 4 to 8 CP CoolNoNc NC eatnonc NC Fan Cont

1 Tx / x 2 7 Vdc Power Supply 3 SC3514E5045 4 UI 1 008-0568 5 S WITE 90-277 Vac - 50/60 z 6 BI 2 1/2P + 5A b. Amb. Temp. 50 o C 7 SS BACK 8 S OW ED 9 Occ 1/2 P ED BUE 10 IG BOWN 5A COO YEOW OANGE EAT OANGE 90-277 Vac 10A Amb. Temp. 50 o C STATUS Use copper conductors ade in Canada 75 o C min. only. Sequence of operation and wiring Occupied ode: occupied cooling and heating. The occupancy output will open the fresh air damper to minimum position. Stand-by ode (only available when PI motion detector cover is used): stand-by cooling and heating. Unoccupied ode: unoccupied heating and cooling. The fresh air damper will close. Occupied Override ode: The system will revert to occupied mode for the duration determined by the ToccTime parameter. On a call for cool: If the supply water temperature is less than 24 C (75F), the cooling valve will open to maintain room temperature. eating valve is closed. On a call for heat: If the supply water temperature is greater than 25 C (77F), the heating valve will open to maintain room temperature. Cooling valve is closed. Supply Air Sensor: Only used for monitoring. Will be displayed automatically if sensor is connected. SE7300A Controller Tx-x 7 VDC CO BI1 SCO BI2 SC3514E SC3514E elay Pack Tx/x 7 VDC CO UI 1 SCO BI 2 SS S To Fan Coil Unit (igh Voltage Side) OCC Fresh Air Damper elay Typical Wiring Example for SC elay Pack Brown - igh Speed Blue - edium Speed ed - ow Speed Yellow - Cooling Valve For 2 pipe applications use cooling valave yellow wire connection For electric reheat applications wher ecurrent draw is under above 10A use a line powered coil pilot duty relay contactor for the heating element in place of the heating valve. V Black - ive Power White - Neutral Options BACnet and Wireless communication models available (see Appendix B for network wiring). emote wall mount or duct sensor ready. Can be configured for 2 pipe systems (with changeover). Binary inputs can be configured to control occupancy via door or window contact, remote night setback or to provide alarms for service or filter monitoring / Universal input can be configured for a changeover sensor. www.schneider-electric.com 45

1 Tx / x 2 7 Vdc Power Supply 3 SC3300E5045 008-0563 WITE 90-277 Vac - 50/60 z 1/2P + 5A b. Amb. Temp. 50 o C BACK OW ED 9 eat- 1/2 P ED BUE 10 eat+ IG BOWN 5A COO YEOW STATUS Use copper conductors 75 o C min. only. ade in Canada 1 Tx / x 2 7 Vdc Power Supply 3 SC3500E5045 008-0566 WITE 90-277 Vac - 50/60 z 1/2P + 5A b. Amb. Temp. 50 oc BACK ED OW 1/2 P BUE ED BOWN IG 5A COO YEOW OANGE EAT OANGE 90-277 Vac 10A Amb. Temp. 50 oc STATUS Use copper conductors ade in Canada 75 oc min. only. SE7300A5045 -SC3500E5045 -SC3300E5045: eating/cooling: 4-pipe fan coil unit with 3-speed fan, 2-position valves with slave relay pack Cooling Coil eating Coil SC3300E 2-Position Cooling Valve 2-Position eating Valve Optional PI cover: COV-PI-FCU-C-5045. SE7300A Configuration parameter name SC3500E Configuration settings efer to Schneider Electric Catalogue for valves and actuators. 46 Schneider Electric Fan coil application guide PswrdSet 0 is factory set, range is: 0-1000 BI1 BI2 UI1 BI2 enuscro Autoode C or F As per user. Default value = F % disp OFF ockout As per user. Default value = 0 No lock Pulsedt OFF Pipe No 4.0 SeqOpera 2 = Cooling / eating 4 pipes Fan enu 2 DumiCK % set As per user. Default value = 50%. ange = 30% to 95% Dehuyst As per user. Default value = 5%. ange = 2% to 20% DehuCool As per user. Default value = 100%. ange = 20% to 100% St-By T 0.5 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments Unocc T 0.0 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments St-By T 69 F is factory set, range is: 40 to 90 F ( 4.5 to 32.0 C ) St-By C 78 F is factory set, range is: 54 to 100 F ( 12.0 to 37.5 C ) Unocc T As per user. Default value = 62 F ( 17 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) Unocc C As per user. Default value = 80 F ( 27 C ). ange = 54 to 100 F ( 12 to 37.5 C ) heat max As per user. Default value = 90 F ( 32 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) cool min As per user. Default value = 54 F ( 12 C ). ange = 54 to 100 F ( 12 to 37.5 C ) Pband 3 F is factory set, range is: 2 to 10 F ( 0.6 to 5.6 C ) Set Type Permanent SptFunc Dual Stp or AttchStp TOccTime As per user. Default value 2 hours. ange = 0 to 24 hours deadband As per user. Default value 2.0 F ( 1.0 C ). cal S 0 F or C cal 0 F or C Auto Fan AS or AS AD Cool cph As per user. 4 to 8 CP eat cph As per user. 4 to 8 CP CoolNoNc NC eatnonc NC Fan Cont

1 Tx / x 2 7 Vdc Power Supply 3 008-0566 WITE 90-277 Vac - 50/60 z 1/2P + 5A b. Amb. Temp. 50 o C BACK ED OW 1/2 P BUE ED BOWN IG 5A COO YEOW OANGE EAT OANGE 90-277 Vac 10A Amb. Temp. 50 o C STATUS Use copper conductors 75 o C min. only. ade in Canada Sequence of operation and wiring Occupied ode: occupied cooling and heating. Stand-by ode (only available when PI motion detector cover is used): standby cooling and heating. Unoccupied ode: unoccupied heating and cooling. Occupied Override ode: The system will revert to occupied mode for the duration determined by the ToccTime parameter. On a call for cool: Cooling valve will open to maintain room temperature. eating valve is closed. On a call for heat: eating valve will open to maintain room temperature. Cooling valve is closed. SE7300A Controller Tx-x 7 VDC CO BI1 SCO BI2 SC3500E5045 SC3500E elay Pack Tx/x 7 VDC CO To Fan Coil Unit (igh Voltage Side) SC3300E Slave elay Pack Tx/x 7 VDC To Fan Coil Unit (igh Voltage Side) CO Typical Wiring Example for SC elay Pack Black - ive Power Orange - Connected to Black-ive Power White - Neutral Brown - igh Speed Blue - edium Speed ed - ow Speed Orange - eating Valve V SC3500E Yellow - Cooling Valve V Options BACnet and Wireless communication models available (see Appendix B for network wiring). emote wall mount or duct sensor ready. Can be configured for 2 pipe systems (with changeover). For 2 pipe applications use cooling valave yellow wire connection For electric reheat applications wher ecurrent draw is under above 10A use a line powered coil pilot duty relay contactor for the heating element in place of the heating valve. Binary inputs can be configured to control occupancy via door or window contact, remote night setback or to provide alarms for service or filter monitoring / Universal input can be configured for a changeover sensor. www.schneider-electric.com 47

1 Tx / x 2 7 Vdc 3 4 UI 1 5 S 6 BI 2 7 SS 8 S 9 eat- 1/2 P ED 10 eat+ IG 5A COO STATUS Use copper conductors 75 o C min. only. Power Supply SC3404E5045 008-0565 WITE 90-277 Vac - 50/60 z 1/2P + 5A b. Amb. Temp. 50 o C BACK OW ED BUE BOWN YEOW ade in Canada SE7300A5045 - SC3504E5045: Cooling and electric heat: 2-pipe fan coil unit with 3-speed fan, 2-position valves with wired window switch Window Switch eating/cooling Coil C/O Sensor Supply Sensor Optional PI cover: COV-PI-FCU-C-5045. Changeover Sensor: 10K Ohm type 2. Configuration parameter name SE7300A SC3504E Configuration settings Supply Sensor: 10K Ohm type 2. Window Switch: Generic Window Switch efer to Schneider Electric Catalogue for valves and actuators. 48 Schneider Electric Fan coil application guide PswrdSet 0 is factory set, range is: 0-1000 BI1 Window BI2 UI1 COS BI2 enuscro Autoode C or F As per user. Default value = F % disp OFF ockout As per user. Default value = 0 No lock Pulsedt OFF Pipe No 2.0 SeqOpera 2 = Cooling with Electric eheat Fan enu 2 DumiCK % set As per user. Default value = 50%. ange = 30% to 95% Dehuyst As per user. Default value = 5%. ange = 2% to 20% DehuCool As per user. Default value = 100%. ange = 20% to 100% St-By T 0.5 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments Unocc T 0.0 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments St-By T 69 F is factory set, range is: 40 to 90 F ( 4.5 to 32.0 C ) St-By C 78 F is factory set, range is: 54 to 100 F ( 12.0 to 37.5 C ) Unocc T As per user. Default value = 62 F ( 17 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) Unocc C As per user. Default value = 80 F ( 27 C ). ange = 54 to 100 F ( 12 to 37.5 C ) heat max As per user. Default value = 90 F ( 32 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) cool min As per user. Default value = 54 F ( 12 C ). ange = 54 to 100 F ( 12 to 37.5 C ) Pband 3 F is factory set, range is: 2 to 10 F ( 0.6 to 5.6 C ) Set Type Permanent SptFunc Dual Stp or AttchStp TOccTime As per user. Default value 2 hours. ange = 0 to 24 hours DoorTime N/A deadband As per user. Default value 2.0 F ( 1.0 C ). cal S 0 F or C cal 0 F or C Auto Fan AS or AS AD Cool cph As per user. 4 to 8 CP eat cph As per user. 4 to 8 CP CoolNoNc NC eatnonc NC Fan Cont

1 Tx / x 2 7 Vdc Power Supply 3 4 UI 1 008-0567 5 S WITE 90-277 Vac - 50/60 z 6 BI 2 1/2P + 5A b. Amb. Temp. 50 oc 7 SS BACK 8 S ED OW 1/2 P BUE ED BOWN IG 5A COO YEOW STATUS Use copper conductors 75 oc min. only. EAT OANGE OANGE 90-277 Vac 10A Amb. Temp. 50 oc ade in Canada Sequence of operation and wiring Occupied ode: occupied cooling and heating. Stand-by ode (only available when PI motion detector cover is used): standby cooling and heating. Unoccupied ode: unoccupied heating and cooling. Occupied Override ode: The system will revert to occupied mode for the duration determined by the ToccTime parameter. On a call for cool: If the supply water temperature is less than 24 C (75F), the cooling valve will open to maintain room temperature. eating valve is closed. On a call for heat: If the supply water temperature is greater than 25 C (77F), the heating valve will open to maintain room temperature. Cooling valve is closed. Supply Air Sensor: Only used for monitoring. Will be displayed automatically if sensor is connected. Wireless Window Switch: The window switch will automatically lock out heating/cooling when window is opened. Options SE7300A Controller Tx-x 7 VDC CO BI1 SCO BI2 SC3504E Typical Wiring Example for SC elay Pack SC3504E5045 Window Contact Brown - igh Speed Blue - edium Speed ed - ow Speed Yellow - Cooling Valve SC3504 elay Pack Tx/x 7 VDC CO UI 1 SCO BI 2 SS S For 2 pipe applications use cooling valave yellow wire connection For electric reheat applications wher ecurrent draw is under above 10A use a line powered coil pilot duty relay contactor for the heating element in place of the heating valve. V To Fan Coil Unit (ight Voltage Side) Black - ive Power White - Neutral BACnet and Wireless communication models available (see Appendix B for network wiring). odels available with factory installed PI cover. emote wall mount or duct sensor ready. Can be configured for 2 pipe systems (with changeover). Binary inputs can be configured to control occupancy via door or window contact, remote night setback or to provide alarms for service or filter monitoring / Universal input can be configured for a changeover sensor. www.schneider-electric.com 49

1 Tx / x 2 7 Vdc Power Supply 3 SC3500E5045 008-0566 WITE 90-277 Vac - 50/60 z 1/2P + 5A b. Amb. Temp. 50 oc BACK ED OW 1/2 P BUE ED BOWN IG 5A COO YEOW OANGE EAT OANGE 90-277 Vac 10A Amb. Temp. 50 oc STATUS Use copper conductors ade in Canada 75 oc min. only. SE7300A5045 - SC3500E5045: eating/cooling: 4-pipe fan coil unit with 3-speed fan, 2-position valves with wired door switch Cooling Coil eating Coil Door Swtich 2-Position Cooling Valve 2-Position eating Valve Optional PI cover: COV-PI-FCU-C-5045. Door Switch: Generic wired door switch. SE7300A SC3500E efer to Schneider Electric Catalogue for valves and actuators. Configuration parameter name Configuration settings 50 Schneider Electric Fan coil application guide PswrdSet 0 is factory set, range is: 0-1000 BI1 Door BI2 UI1 BI2 enuscro Autoode C or F As per user. Default value = F % disp OFF ockout As per user. Default value = 0 No lock Pulsedt OFF Pipe No 4.0 SeqOpera 2 = Cooling / eating 4 pipes Fan enu 2 DumiCK % set As per user. Default value = 50%. ange = 30% to 95% Dehuyst As per user. Default value = 5%. ange = 2% to 20% DehuCool As per user. Default value = 100%. ange = 20% to 100% St-By T 0.5 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments Unocc T 0.0 hours is factory set, range is: 0.0 to 24.0 hours in 0.5hr increments St-By T 69 F is factory set, range is: 40 to 90 F ( 4.5 to 32.0 C ) St-By C 78 F is factory set, range is: 54 to 100 F ( 12.0 to 37.5 C ) Unocc T As per user. Default value = 62 F ( 17 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) Unocc C As per user. Default value = 80 F ( 27 C ). ange = 54 to 100 F ( 12 to 37.5 C ) heat max As per user. Default value = 90 F ( 32 C ). ange = 40 to 90 F ( 4.5 to 32.0 C ) cool min As per user. Default value = 54 F ( 12 C ). ange = 54 to 100 F ( 12 to 37.5 C ) Pband 3 F is factory set, range is: 2 to 10 F ( 0.6 to 5.6 C ) Set Type Permanent SptFunc Dual Stp or AttchStp TOccTime As per user. Default value 2 hours. ange = 0 to 24 hours deadband As per user. Default value 2.0 F ( 1.0 C ). cal S 0 F or C cal 0 F or C Auto Fan AS or AS AD Cool cph As per user. 4 to 8 CP eat cph As per user. 4 to 8 CP CoolNoNc NC eatnonc NC Fan Cont

Tx / x 7 Vdc Power Supply 008-0566 WITE 90-277 Vac - 50/60 z 1/2P + 5A b. Amb. Temp. 50 o C BACK ED OW 1/2 P BUE ED BOWN IG 5A COO YEOW OANGE EAT OANGE 90-277 Vac 10A Amb. Temp. 50 o C STATUS Use copper conductors 75 o C min. only. ade in Canada Sequence of operation and wiring Occupied ode: occupied cooling and heating. Stand-by ode (only available when PI motion detector cover is used): standby cooling and heating. Unoccupied ode: unoccupied heating and cooling. Occupied Override ode: The system will revert to occupied mode for the duration determined by the ToccTime parameter. On a call for cool: Cooling valve will open to maintain room temperature. eating valve is closed. On a call for heat: eating valve will open to maintain room temperature. Cooling valve is closed. Door Switch: The door switch will automatically toggle occupancy. Options SE7300A Controller 1 2 3 Tx-x 7 VDC CO BI1 SCO BI2 SC3500E5045 SC3500E Typical Wiring Example for SC elay Pack Brown - igh Speed Blue - edium Speed ed - ow Speed Orange - eating Valve Yellow - Cooling Valve SC3500E elay Pack Tx/x 7 VDC CO Door Contact For 2 pipe applications use cooling valave yellow wire connection For electric reheat applications wher ecurrent draw is under above 10A use a line powered coil pilot duty relay contactor for the heating element in place of the heating valve. V V To Fan Coil Unit (igh Voltage Side) Black - ive Power Orange - Connected to Black-ive Power White - Neutral BACnet and Wireless communication models available (see Appendix B for network wiring). odels available with factory installed PI cover. emote wall mount or duct sensor ready. Can be configured for 2 pipe systems (with changeover). Binary inputs can be configured to control occupancy via door or window contact, remote night setback or to provide alarms for service or filter monitoring / Universal input can be configured for a changeover sensor. www.schneider-electric.com 51

Check in to comfort. Check out the savings. otel guest comfort meets energy savings with SE7000 Series room controllers. 52 Schneider Electric Fan coil application guide

Appendix A - Passive infra-red (PI) motion detector cover specifications PI cover sequence of operation Initially, the controller is in Stand-by mode. Stand-by setpoints are used at the controller. As soon as the PI detects a movement or motion, the Occupancy status switches to Occupied and the Stand- By Time timer is reset. The Occupied setpoints are used. If no motion is detected in the room for the entire Stand-By Time duration (adjustable parameter), the room then switches to Stand-by mode and stand-by setpoints are used. While in Stand-by mode, if no motion is detected for the entire Unoccupied Time period (adjustable parameter), the room switches to Unoccupied mode and uses its Unoccupied setpoints. While in Stand-By or Unoccupied mode, any motion will switch the room back to Occupied mode. PI cover accessory PI eady Controllers SE()73x0X5045 (mercial) SE()73x5X5045 (ospitality/odging) Part Number COV-PI-FCU-C-5045 COV-PI-FCU--5045 Typical Detection Pattern for PI ens orizontal Angle (typical) Vertical Angle (typical) 120 CENTE 6.1 eters (20 Feet) 15 15 45 6.1 eters (20 Feet) 4.6 eters (15 Feet) CENTE 4.6 eters (15 Feet) 6.1 eters (20 Feet) Energy savings The PI can maximize your energy saving from 10-30% by relaxing temperature set points in unoccupied zones during scheduled periods. Energy Usage (KWh) 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5 0 Typical Savings of 10-30% 0% 0 2 4 6 8 10 12 14 16 18 20 22 24 Time of Day (EST) Typical Consumption PI Thermostat Consumption Savings 50% 40% 30% 20% 10% Saving Percentage www.schneider-electric.com 53

Appendix B - option network wiring if communicating models are used BACnet communication wiring BACnet thermostat 1 + - ref Echelon communication wiring Echelon thermostat 1 Wireless communication BACnet thermostat 2 + - ref Echelon thermostat 2 BACnet thermostat 3 + - ref Echelon thermostat 3 Notes: - No communication wires needed Notes: - Wiring should be daisy chained - espect polarity - If using 2 conductors shielded wires, connect the shield of each feed together on the back of the controller. Y ground the shield at one location. DO NOT connect the shield to the ref terminal. Notes: - No polarity Appendix C - controllers occupancy sequence of operation schematic Setpoints Unoccupied cool Stand-by cool Occupied cool Occupied heat Stand-by heat Unoccupied heat 22 C 72 F Deadband Stand-by time 24.5 C 76 F Deadband Unoccupied time 26.5 C 80 F 70 F 70 F 21 C 21 C 66 F 19 C Deadband 62 F 16.5 C 22 C 72 F Time ovement detected - Stand-by timer reset Into Stand-by mode - Unoccupied timer reset Into Unoccupied mode Next movement detected 54 Schneider Electric Fan coil application guide

Appendix D - VWA5000 series - wireless door & window switch Wirelss door & window switch Wireless door switches used with the local PI cover provide advanced local occupancy routines allowing for increased energy savings during occupied hours without sacrificing occupant comfort. The wireless swtiches are only compatible with the SE7300 Series Controllers. Wireless window switches are used to monitor outside windows and or patio and balcony doors being opened or closed. This allows preventing unnecessary energy consumption by the tenants. Typical applications of Fan Coil Terminal Equipment Controllers with VWA5000W series Zigbee wireless switches can be used in network ready mode with or without integration to a central management system to allow for advanced functions such as central reservation occupancy functions. A combination of up to twenty VWA5000W door and or window switches can be used simultaneously with a single Fan Coil Terminal Equipment Controller. The VWA5000W switches are factory delivered with 2 AAA batteries and are ready to be installed, configured and used right out of the box. Due to the extremely small current consumption of the switches, the expected battery life is approximately 10 years and is equivalent to the battery shelf life. No tools are required for commissioning or servicing the door switch. A very simple interface with an on-board ED & hidden switch provide all the required functions for local interaction. ocal information for battery life and connectivity (heartbeat) are provided at the Fan Coil Terminal Equipment Controller local display level or through the Zigbee wireless network. Each switch is also factory supplied with a magnet, a locking security tamper proof screw and self tapping mounting screws for installation. odel selection Window Switch Door Switch VWA5045W5045W VWA5045D5045W Simple & quick installation ED (switch side) Pull Tab idden Switch www.schneider-electric.com 55

Specifications Power requirements: 3.0 VDC 2 x AAA batteries. Factory supplied Operating conditions: 0 C to 50 C ( 32 F to 122 F ) 0% to 95%.. non-condensing Storage conditions: -30 C to 65 C ( -22 F to 122 F ) 0% to 95%.. non-condensing Agency Approvals all models Agency Approvals Wireless models CE: TTE 1999/5/EC FCC: pliant to: Part 15, Subpart CT Dimensions 18.16 mm (0.716 ) 24.38 mm (0.960 ) 21.13 mm (0.832 ) 118 mm (4.646 ) 8.84 mm (0.348 ) 121.92 mm (4.800 ) Switch & Switch base Dimensions 3.18 mm (0.125 ) 35.97 mm (1.416 ) 18.16 mm (0.716 ) 18.16 mm (0.716 ) 39.37 mm (1.550 ) agnet & agnet Dimensions 56 Schneider Electric Fan coil application guide

1 Tx / x 2 7 Vdc Power Supply 3 SC3404E5045 4 UI 1 008-0565 5 S WITE 90-277 Vac - 50/60 z 6 BI 2 1/2P + 5A b. Amb. Temp. 50 oc 7 SS BACK 8 S OW ED 9 eat- 1/2 P ED BUE 10 eat+ IG BOWN 5A COO YEOW STATUS Use copper conductors 75 oc min. only. ade in Canada Appendix E - SE7300 controller & SC3000 relay pack Product overview The SE7300 Fan Coil Controller offers a new cost-effective solution for upgrading line-voltage fan coil unit thermostats. The SE7300 terminal Equipment Fan Coil Unit Controllers are available as Network eady, BACnet STP or wireless ZigBee networked models. No previous building automation training is required for the easy installation and commissioning process. Installation can be completed in approximetly fifteen minutes, reducing costs and providing increased savings. The SC3000 Series ine Voltage Switching Transformer elay Pack Controllers has been designed for silent control of typical high voltage fan coil device loads (90 to 277 VAC multi-voltages capable). It uses advanced microprocessor-based circuitry with a built-in transformer that eliminates all typical required peripheral components when automating a Fan Coil unit with traditional building automation systems. The SC3000 Series ine Voltage Switching Transformer elay Pack(s) operate as slave unit(s) under the control of a single master SE73XX Terminal Equipment Controller. A single SE73XX Terminal Equipment Controller can control up to 10x SC3000 Series elay Pack. The SC3000 Series elay Packs are line-powered units. The extremely compact unit locally contains all the relay outputs for fan switching and valve control. odels are also available for extra monitoring / control inputs of the Fan Coil Units. Typical fan coil unit setup TYPICA COI UNIT Electrical Cabinet C C C ow Voltage Connections to VT7300 Controller Daisy Chained Topology ixed Daisy Chained & Star Topology Star Topology www.schneider-electric.com 57

elay pack specifications Power Supply: 90 to 277 VAC universal, 50-60 z Fan line voltage contact electrical ratings: Brown, Blue, ed wires ½ P maximum ain heat and cool line voltage contact electrical ratings: Yellow wire 10A maximum Isolated heat line voltage contact electrical ratings: Orange wires 10A maximum Output ratings: -eat Valve: (Orange wire): 10 Amps @ 277 VAC maximum -Cool Valve: (Yellow wire): 5 Amps @ 277 VAC maximum -Fan: (red, blue, brown wire(s)): 0.37 kw (1/2 P) @ 277 VAC maximum Operating conditions: 0C to 50C (32F ro 122F) 0% to 95% non-condensing Approximate shipping weight: 0.75lb (0.34kg) Agency approvals all models: ctuvus: U 873 (US) and CSA C22.2 No. 24 (Canada) CE: VD 2006/95/EC (Europe Union) CE: EC 2004/108/EC (Europe Union) CE for F: TTE 1999/5/EC FCC: pliant to: Part 15, Subpart B FCC for F: pliant to: Part 15, Subpart C Dimensions 1 Tx / x 33mm (1.30") 2 7 Vdc 3 4 UI 1 5 S 6 BI 2 7 SS Power Supply SC3404E5045 008-0565 WITE 90-277 Vac - 50/60 z 1/2P + 5A b. Amb. Temp. 50 o C BACK 8 S OW ED 80mm (3.15") 9 eat- 10 eat+ 1/2 P ED IG 5A COO BUE BOWN YEOW 100mm (3.94") STATUS Use copper conductors 75 oc min. only. ade in Canada 122mm (4.80)" 70mm (2.75") 80mm (3.15") 58 Schneider Electric Fan coil application guide