ABB MEASUREMENT & ANALYTICS DATA SHEET. DAT200 Asset Vision Basic and DTM Device Typ Manager

Similar documents
DTM Bundle & DAT200 Asset Vision Basic for intelligent field devices

Introduction. For more information. HART Protocol 7.0 Valid for software levels from 05.00

ControlMaster PC Configuration

EngineerIT Device Management Tool DSV4xx (SMART VISION)

EngineerIT Device Management Tool SV401 SMART VISION

Using the WirelessHART transmitter TTF300-W as repeater to extend the availability of a WirelessHART network

Adapter Plates for continuous Part-Turn Actuators (Contrac)

EngineerIT Device Management Tool DSV401 (SMART VISION)

Introduction. Additional Information

HART adapters. Data Sheet. HART FSK/PC modem USB Ex(Haz.) and Non-Ex(Haz.) applications

FICHA TÉCNICA DE PRODUTO

ScreenMaster series Paperless recorders

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. WirelessHART components Gateway and accessories

ControlMaster controllers and indicators ConfigPilot

ABB MEASUREMENT & ANALYTICS DATA SHEET. DataManager Pro RDM500 Advanced data review software

Crane-Boy / Crane-BoyP Load limitation electronics

Driver ABB DTM500 Bundle

SM1000 Videographic recorder Spare parts and upgrade kits

SM2000 Videographic recorder Spare parts and upgrade kits

ABB MEASUREMENT & ANALYTICS DATA SHEET. DataManager Pro RDM500 Advanced data review software

INDI BOY DSP Load limitation electronics

Diagnostic and verification software ScanMaster FZC500

ControlMaster CM15, CM30 and CM50 Universal process indicator and controllers Customizing the operator page displays

LME620-AI/-AN (Contrac) Electrical Linear Actuator

ControlMaster CM10, CM30, CM50 and CM15 Universal process controllers and indicator Spare parts

C160 Wall-/Pipe Mounted Universal Process Indicator

TROVIS-VIEW software TROVIS 6661

Supplementary - Information 3KDE150021R3901 Rev. D. Content. Driver 2600T(261xx)-HART. Pressure and Level Transmitter

RTU560 Connections and Settings DIN Rail RTU 560CIG10

Technical Information FieldCare SFE500

2600T Series Pressure Transmitters How to replace Profibus PA pressure transmitters with the 266 PA

CEM-DAS Digital interface Data acquisition and handling system for continuous emission monitoring Software version 1.2.4

ControlMaster CMF160 Universal process indicator, fieldmount

ABB MEASUREMENT & ANALYTICS DATA SHEET. C1950 (STLR & HTST) Pasteurizer recorder and recorder / controller

VeriMaster. Software tools. Measurement made easy. Overview

System 800xA The Power of Integration. 800xA Device Management and Fieldbus Overview

TEPI11 P/I signal converter

TZIDC, TZIDC-200 HART

FICHA TÉCNICA DE PRODUTO

FICHA TÉCNICA DE PRODUTO

CPU module for zone 2 Series 9442/35

DSV401 R3 (SMART VISION) Device Management Tool for Intelligent Field Instruments ABB

CoriolisMaster mass flowmeter Automation solution for mixing applications

FBP FieldBusPlug. Technical Manual. USB to FBP UTF21-FBP UTF21-FBP DTM V

ishrt USB ishrt USBeX the Bluepack User Manual

Technical Information Field Xpert SMT70

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. RSDE10 / RSDE20 (Contrac) Electrical linear actuator

ControlMaster CMF160 Universal process indicator, fieldmount

Technical Information DeviceCare SFE100

C1950 (STLR & HTST) Pasteurizer Recorder and Recorder Controller

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. RSD50 (Contrac) Electrical linear actuator

S900 Remote I/O System Intrinsic safety in the field ABB

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. RSDE50 (Contrac) Electrical linear actuator

Process Automation Device Information Model. Technical White Paper

ABB MEASUREMENT & ANALYTICS DATA SHEET. IT1 Universal weighing terminal

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. RHD16000 (Contrac) Electrical rotary actuator

Digital Indicator DS 48/24 E

Indicomp 4 Bargraph Indicator

SIMATIC PDM - The Process Device Manager

General. Remote I/O A4/1.

ABB Instrumentation. Powerful Device Management A tool checks everything. Reference case study. Stadtwerke Kiel AG. Instrumentation Solutions

ControlIT Process controller

Model DHH805 Handheld communicator. HART fieldbus tools Handheld configuration devices

Application Note. a HART Tool-routing with Emerson AMS HART over TH LINK PROFIBUS for Asset Management 1.0.0

Fieldbus Gateway Type ME43

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. LME620-AI / LME620-AN (Contrac) Electrical linear actuator

WirelessHART Adapter SWA70

How to connect ABB Ethernet inverters with VSN700 Data Logger over Ethernet

ControlMaster CM15 Universal process indicator, 1 /8 DIN. Making process control easy

INFORMATION. SM Series Videographic Recorders PC Emulator Quick Start Guide. 1 Emulation Tips. Manual IM/SM500F, IM/SM1000, IM/SM2000, IM/SM3000

SwirlMaster The new generation of swirl flowmeters

ControlMaster CM10 Universal process controller, 1 /8 DIN. Making process control easy

NETL ink gateways. Ethernet gateways WLAN gateways High-speed USB gateways

Advanced Diagnostics / Premium Diagnostics

Your Global Automation Partner. excom I/O System

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

AC500-eCo: your PLC from ABB Unique scalable concept, optimal costs... Change for more!

LineMaster 100 Continuous-line Recorder

AUMA 50 YEARS OF ELECTIC ACTUATON

Motor control and protection Universal Motor Controller UMC100-FBP

FICHA TÉCNICA DE PRODUTO

SIMATIC. Process Control System PCS 7 Help for SIMATIC PDM (V8.1 SP1) Preface 1. Using SIMATIC PDM 2. Installation 3. PDM Exportfile Converter 4

ABB Ability Verification for measurement devices

Wall-/Pipe Mounted Universal Process Indicator

Technical Information Field Xpert SMT70

/8 DIN Motorized Valve Controller

ABB MEASUREMENT & ANALYTICS DATA SHEET. Totalflow host software System software products

AX400 series Single and dual input analyzers


DF PROFI II PC/104-Plus

Programming unit VIATOR HART modems Model PU-H

Industrial IT. Asset Vision Professional 5.0 SP2. Basic Configuration and Operation

JUMO mtron T. Measuring, Control, and Automation System. Features. Brief description. Systembus LAN. Data Sheet Page 1/12. Com1.

INSTRUCTION MANUAL ABB Power Quality Link Installation and user guide

APPLICATION NOTE. Advanced Diagnostic PRM Integration. COM port Packing and Field Device Tag Import

Printer Interface (6370) Setup. Replaces discontinued Printer Interface (4370)

LVX Control Unit. Features:

FICHA TÉCNICA DE PRODUTO

SSW7. User Manual. Adapter for MPI-Bus. Version:2 / HW: 1 / FW: 3.0 and higher. Order number of manual: VK21/en VK21

/8 DIN Universal Process Indicator

Transcription:

ABB MEASUREMENT & ANALYTICS DATA SHEET DAT200 Asset Vision Basic and DTM Device Typ Manager

2 DAT200 ASSET VISION BASIC AND DTM DEVICE TYP MANAGER DS/DTM/DAT200-EN REV. G Measurement made easy DTM500 Contains ABB device driver (DTM) Supports FDT Standard 1.2/1.2.1 Adheres to the FDT Style Guide Graphics-based overview of DTM functions Easy Set-up wizard Diagnostics in accordance with NAMUR NE107; provide additional maintenance information DTM400 Contains ABB device driver (DTM) Supports FDT Standard 1.2 Diagnostic information DAT200 Asset Vision Basic FDT frame application for configuration, diagnostics, and maintenance tasks on intelligent devices Supports FDT Standard 1.2/1.2.1 Supports all current fieldbus protocols via communication DTMs Point-to-point wizard Create a project tree at the touch of a button Structured according to user accounts in line with the FDT Style Guide, with optional password protection Online help Supported by.net 3.5

Change from one to two columns DAT200 ASSET VISION BASIC AND DTM DEVICE TYP MANAGER DS/DTM/DAT200-EN REV. G 3 FDT / DTM technology FDT technology makes an important contribution towards ensuring unrestricted utilization of the fieldbus potential by standardizing the communication interface between the field devices and the systems. A key feature is its independence from the communications protocol, the software environment for the devices, and the host systems. Using FDT, it is possible for any host to access any device - via any protocol. The heart of the FDT concept lies in the Device Type Manager (DTM), a component offered by ABB for a multitude of It can be used in any system that supports the FDT interface. The DTM is the configuration and management component of a field device. It is familiar with all the rules governing devices (plausibility checks), and contains all graphical user dialogs, the device configuration, diagnostics, and maintenance. DTMs are loaded into the libraries of the automation system or of stand-alone tools, in a similar way to a printer driver in an office environment. DTM (Device Type Manager) General ABB DTM400 and ABB DTM500 are designations given to different ABB driver libraries for HART, PROFIBUS, FOUNDATION Fieldbus and Modbus Areas of application Configuration and parameterization of devices Diagnosis of devices, retrieval of status messages Online and offline display of device data (measurement data, diagnosis, configuration / parameterization and status information) in multivisual form Parameterize Graphics-based overview of parameter groups Online / offline configuration Uploading device data: read parameterization-/ configuration information from the device Downloading device data: write saved device data back to the device Easy Set-up program wizard for guided, quick parameterization of intelligent devices Non-identical device parameters in instance data set and physical device are clearly marked Online display of measurement and status data Select how measured values are displayed: Numerically As a bar with alarm limits As an analog dial As a trend graph All graphical elements feature a scalable time axis Status and diagnosis in accordance with NAMUR: Includes notices (DTM500) on "possible cause" and "recommended action" Archiving Backup and load TAG-related device data Print selected device data (DTM500)

Change from two to one column Change from one to two columns 4 DAT200 ASSET VISION BASIC AND DTM DEVICE TYP MANAGER DS/DTM/DAT200-EN REV. G... DTM (Device Type Manager) Miscellaneous Select from two display windows (DTM500): Main Operation Display all of the DTM-functions in a single window Application Display selected DTM-functions in individual windows. Navigation area with tree structure (DTM500) Comprehensive online help available throughout the DTM Note Information on System requirements (hardware / software), Number and type of DTMs in each of the bundles, Licensing is available either in Supplement Info under \Documentation on the data storage medium supplied, or in its current version at www.abb.com/fieldbus. On the Internet site, enter the following number in the Search box: for the DTM400 device driver 3KXD801400R3903 for the DTM500 device driver 3KXD801500R3903 Overview of the drivers and applications Software FDT Specification Windows operating system * DTM 1.2 1.2.1 7 (32/64-Bit) 8.1, 10 (32/64-Bit) Style guide Graphic Summary Easy Set-up DTM400 DTM500 DAT200 * For minimum operating system requirements (e. g. Service Pack) see Requirements in the supplementary information of the software.

DAT200 ASSET VISION BASIC AND DTM DEVICE TYP MANAGER DS/DTM/DAT200-EN REV. G 5 DAT200 Asset Vision Basic General Asset Vision Basic is an FDT frame application used for configuration, diagnosis and maintenance tasks on intelligent Asset Vision Basic offers support for devices using all current communication protocols via communication DTMs. Asset Vision Basic contains a point-to-point wizard that is not only intuitive for users but also enables a device to be parameterized quickly. Asset Vision Basic conforms to FDT Specification 1.2.1. and supports FDT 1.2; it is, therefore, open for certified DTMs. Asset Vision Basic is supported by.net 3.5. Areas of application Provides the FDT frame for DTMs (device DTMs, communication DTMs, remote I/O DTMs, and so on) Straightforward tool for quick device parameterization (point-to-point wizard) Visual device overview that maps device communication links in systems (project tree) Storage / management of device data Device measuring point planning and management Management Management of devices and networks in projects Display and management of all installed DTMs (device catalog), incl. a filter function for sorting by: Device type Manufacturer Groups Protocols Assignment of measuring point names (TAG names) in the project manager (network) Assignment of device / DTM addresses in the project manager (network) via the communication DTMs Device recognition via device TAG number or address Simultaneous communication (online) with several devices Scanning of devices connected via communication DTMs Automatic generation of a project tree in the project manager (network) via communication DTMs Archiving Back up and load project-related data Print project-related data Point-to-point (Tool Mode) wizard The wizard guides you in opening a project for a device. The wizard assists you in configuring communication interfaces, finding the device, and selecting the right DTM. The wizard offers three modes: Online Automatic device selection, connection to device, and reading of device data Offline Manual device selection and display of device instance data File open Opens a previously saved point-to-point project in offline or online mode Miscellaneous Password protection available for user accounts with fixed roles Language settings Configuration of Tool Mode wizard Configuration of frame window and shortcuts Option of connecting FDT and error monitor Adaptable tool bar Application view can be switched to a tab or window Comprehensive online help available throughout the tool For minimum operating system requirements (e. g. Service Pack) see Requirements in the supplement information of the software. Note Information on System requirements (hardware / software), Registration is available either in Supplement Info under \Documentation on the data storage medium supplied, or in its current version at www.abb.com/fieldbus. On the Internet site, enter the following number in the Search box: 3KXD151200R3903

6 DAT200 ASSET VISION BASIC AND DTM DEVICE TYP MANAGER DS/DTM/DAT200-EN REV. G Connection types PROFIBUS connection via USB adapter (Option) Ethernet TCP/IP PROFIBUS DP Master USB 1 Communication DTM: is Pro adapter V3 * 3 (Option) Controller 1) 1) 1) Bus termination off! 2) Bus termination on! PROFIBUS DP DP/DP repeater for copper RS 485, FOC, IR DP DP DP DP U S U S Linking Device PA DP U S DP field devices Remote I/O U S 2) PROFIBUS PA 2 4 5 HART field devices PA field devices 2 NDA121-NO 9890002 10/63-6.31 USB - PROFIBUS DP / PC adapter 3 NDE230-NO 9890119 10/63-6.40 DP cable connector, 9-pin, SUB-D incl. switchable bus termination and SUB-D programming connection, 12 Mbps, IP 40 Pin assignment IN: 1A = RxD/TxD-N, 1B = RxD/TxD-P OUT: 2A = RxD/TxD-N, 2B = RxD/TxD-P 4 NDE220-NO 9890118 10/63-6.40 DP cable connector, 9-pin, SUB-D incl. switchable bus termination, 12 Mbps, IP 40 Pin assignment: IN: 1A = RxD/TxD-N, 1B = RxD/TxD-P OUT: 2A = RxD/TxD-N, 2B = RxD/TxD-P 5 PROFIBUS DP cable, violet 989014x 10/63-6.47 NDC110-NO - 2 x 0.32 mm 2 (AWG 22/1), 65 / 330 / 1000 m ABB field device overview PROFIBUS DP 10/63-0.47 PROFIBUS PA 10/63-0.46 Installation suggestions PROFIBUS DP / PA 10/63-0.40 * Recommended adapters / modems M10474-01 Figure 1: PROFIBUS connection via USB adapter

Change from two to one column DAT200 ASSET VISION BASIC AND DTM DEVICE TYP MANAGER DS/DTM/DAT200-EN REV. G 7 PROFIBUS connection via Ethernet gateway 3 (Option) PROFIBUS DP Master Controller 1) 1) 2) Ethernet TCP/IP U S 1 2 Communication DTM: upon request. 2 Ethernet PROFIBUS DP Gateway On request 3 NDE230-NO 9890119 10/63-6.40 DP cable connector, 9-pin, SUB-D incl. switchable bus termination and SUB-D programming connection, 12 Mbps, IP 40 Pin assignment IN: 1A = RxD/TxD-N, 1B = RxD/TxD-P OUT: 2A = RxD/TxD-N, 2B = RxD/TxD-P 1) 2) Figure 2: Bus termination off! Bus termination on! PROFIBUS connection via Ethernet gateway M10475-01 4 5 4 NDE220-NO 9890118 10/63-6.40 DP cable connector, 9-pin, SUB-D incl. switchable bus termination, 12 Mbps, IP 40 Pin assignment: IN: 1A = RxD/TxD-N, 1B = RxD/TxD-P OUT: 2A = RxD/TxD-N, 2B = RxD/TxD-P 5 PROFIBUS DP cable, violet 989014x 10/63-6.47 NDC110-NO - 2 x 0.32 mm 2 (AWG 22/1), 65 / 330 / 1000 m Change from one to two columns HART connection via FSK / USB modem Point-to-point 1 USB 2 Communication DTM: is HRT USB v2 * 2 NHA121-NX 3KDE636710L0001 10/63-6.71 Figure 3: Field device 1) Address 0 HART connection via FSK / USB modem [Ex ia] [Ex ia] 4.. 20 ma / HART ~ Supply unit M10476-01 USB - HART FSK / PC modem, electrical isolation, Ex protection type II (2) G [Ex ia] IIC NHA121-NO 3KDE636710L0002 10/63-6.71 USB - HART FSK / PC modem, electrical isolation, non-ex applications (alternative, not shown) * Any HART Not for TSx02 with "FSK 600 baud" Note During workshop operation with a power supply unit, a 250 -resistor must be connected in series.

8 DAT200 ASSET VISION BASIC AND DTM DEVICE TYP MANAGER DS/DTM/DAT200-EN REV. G... Connection types HART Multidrop network via FSK / USB-modem Field device Address 1 Field device Address 2 Field device Address 3 Field device [Ex ia] 4.. 20 ma / HART 1 USB 2 [Ex ia] ~ Supply unit Communication DTM: is HRT USB v2 * 2 NHA121-NX 3KDE636710L0001 10/63-6.71 USB - HART FSK / PC modem, electrical isolation, Ex protection type II (2) G [Ex ia] IIC NHA121-NO 3KDE636710L0002 10/63-6.71 USB - HART FSK / PC modem, electrical isolation, non-ex applications (alternative, not shown) * HART Not for TSx02 with "FSK 600 baud" Note During workshop operation with a power supply unit, a 250 -resistor must be connected in series. Address 4 Up to 15 addresses are supported M10817-01 Figure 4: HART Multidrop network via FSK / USB modem

Change from two to one column DAT200 ASSET VISION BASIC AND DTM DEVICE TYP MANAGER DS/DTM/DAT200-EN REV. G 9 Contrac connection via Contrac cable / USB 1 Point-to-point USB 2 Device DTM: Contrac HART Communication DTM: ABB HART Communication Service Port RS 232C 3 2 USB RS232C Adapter standard 3 Cable 746349 RS 232C - PC connection cable for Contrac (4 to 20 ma, HART, or PROFIBUS DP-V0/V1) U S Contrac M10477-01 Figure 5: Contrac connection via Contrac cable Change from one to two columns FieldKey wireless HART adapter via FSK / USB modem Figure 6: FieldKey WirelessHART adapter via FSK / USB modem Communication DTM: is HRT USB v2 * 2 NHA121-NX 3KDE636710L0001 10/63-6.71 USB - HART FSK / PC modem, electrical isolation, Ex protection type II (2) G [Ex ia] IIC NHA121-NO 3KDE636710L0002 10/63-6.71 USB - HART FSK / PC modem, electrical isolation, non-ex applications (alternative, not shown) 3 NHU200-WL (FieldKey) DS/NHU200 Wireless upgrade adapter for HART devices, WirelessHART technology * Recommended adapters / modems

Change from two to one column 10 DAT200 ASSET VISION BASIC AND DTM DEVICE TYP MANAGER DS/DTM/DAT200-EN REV. G... Connection types TZIDC HART connection via LCI / USB USB 1 2 Device DTM: ABB Basic HART Communication DTM: not in ABB scope of delivery Recommendation: CodeWrights HARTCommDTM 2 LCI adapter with USB 3KXE000128U0100 OI/LCI- ADAPTER/POSITION ER-XA Field device Address 0 ~ Supply unit M10471249 Local communication interface (LCI) The LCI adapter with LCI service plug is an interface converter to establish a connection between the connected TZIDC-type digital positioner and a PC / Laptop. Figure 7: TZIDC HART connection via LCI / USB Change from one to two columns HART connection via LCI / RS 232 Adapter Device DTM: ABB Basic HART Communication DTM: not in ABB scope of delivery Recommendation: CodeWrights HARTCommDTM 2 NHA201-NO* 319621 10/63-6.71 RS 232C-HART-LKS / PC adapter with small plug for the positioner, TEU421, TEU471, BCI100 * Not suited for USB Figure 8: HART connection via LCI / RS 232 Adapter

Change from two to one column DAT200 ASSET VISION BASIC AND DTM DEVICE TYP MANAGER DS/DTM/DAT200-EN REV. G 11 Modbus connection special for 2600T (267xx / 269xx) via USB / RS 485-converter Half-duplex (A)Tx/Rx + (B)Tx/Rx COM Adress 0 Power GND Field device 2600T (267xx / 269xx) MODBUS RS 485 120 Ohm 24 V DC USB Figure 9: Modbus connection special for 2600T (267xx / 269xx) via USB / RS 485-converter ~ M10818-01 1 2 3 4 5 Supply unit 2 CommDTM Not in ABB scope of delivery Communication DTM for the USB / RS 485 converter. Recommendation: CodeWrights HARTCommDTM 3 DTM MV2010TC Modbus 9820027 DS/DTM/DAT200 Device DTM of 2600T (267xx / 269xx) Modbus Part of the DTM400 bundle Driver for the configuration and parameterization of the field device 4 USB / RS 485 converter Not in ABB scope of delivery At the end on the MODBUS interface with 120 -resistance between (A)Tx/Rx + / (B)Tx/Rx 5 RS 485 cable Not in ABB scope of delivery Half-duplex wiring with (A)Tx/Rx +, (B)Tx/Rx and GND Connect Tx + und Rx + Connect TX and Rx Before starting configuration via DTM, the transmitter function must be switched from Operate to Configuration mode (using the 3 buttons on the device). After configuration is completed, the transmitter must be switched back to Operate. For detailed information see: 42/15-727 EN instruction, chapter 2.

12 DAT200 ASSET VISION BASIC AND DTM DEVICE TYP MANAGER DS/DTM/DAT200-EN REV. G Ordering Information Description Ordering number Device Management Software package (on DVD) incl. DTM and Asset Vision Basic 9820027 The following software packages are in the scope of delivery of the DVD as a single-user license: DTM500 device driver DTM400 device driver DAT200 Asset Vision Basic Universal Basic HART Communication DTM for HART and PROFIBUS Extensive documentation, support, notices and installation tools including license for data storage, import / export, printing DTM500 device driver: Supports FDT Standard 1.2 / 1.2.1 Windows 7 / 8.1, 10 (32/64-Bit) DTM400 device driver Supports FDT Standard 1.2 Windows 7 (32/64-Bit) DAT200 Asset Vision Basic : ABB Software Tool for configuration, diagnosis and maintenance of intelligent devices Supports FDT Standard 1.2 / 1.2.1 Windows 7 / 8.1, 10 (32/64-Bit) Currently available driver types and supplement info are available on line at www.abb.com/fieldbus On the ABB website, enter the following numbers in the search box: For DTM500 3KXD801500R3903 For DTM400 3KXD801400R3903 For DAT200 3KXD151200R3903 Find out more about device management, fieldbus and wireless on the ABB website www.abb.com/fieldbus

Notes DAT200 ASSET VISION BASIC AND DTM DEVICE TYP MANAGER DS/DTM/DAT200-EN REV. G 13

Change from one to two columns 14 DAT200 ASSET VISION BASIC AND DTM DEVICE TYP MANAGER DS/DTM/DAT200-EN REV. G Notes Trademarks HART is a registered trademark of FieldComm Group, Austin, Texas, USA Sales Service WirelessHART is a registered trademark of FieldComm Group, Austin, Texas, USA Windows is a registered trademark of Microsoft Corporation. PROFIBUS and PROFIBUS DP are registered trademarks of PROFIBUS & PROFINET International (PI)

DAT200 ASSET VISION BASIC AND DTM DEVICE TYP MANAGER DS/DTM/DAT200-EN REV. G 15

ABB Limited Measurement & Analytics Howard Road, St. Neots Cambridgeshire, PE19 8EU UK Tel: +44 (0) 870 600 6122 Fax: +44 (0)1480 213 339 Mail: enquiries.mp.uk@gb.abb.com ABB Automation Products GmbH Measurement & Analytics Schillerstr. 72 32425 Minden Germany Tel: +49 571 830-0 Fax: +49 571 830-1806 ABB Inc. Measurement & Analytics 125 E. County Line Road Warminster, PA 18974 USA Tel: +1 215 674 6000 Fax: +1 215 674 7183 abb.com/fieldbus We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents - in whole or in parts is forbidden without prior written consent of ABB. Copyright 2018 ABB. All rights reserved. 3KXD801000R1001 DS/DTM/DAT200-EN Rev. G 02.2018