Front-door station series for surface-mounting Profi-Economic PES Profi-Design PDS

Similar documents
Product Information. DCM Standard indoor stations TK IS A 514 A.. TK IS A 514 AD.. (Design)

Product information combined device with binary input / output, single BRE2-EB

Product information PTZ camera interface FBI

Product information. Modules of the series AMI in front-door stations. for flush-mount kits ZAU200x and communication posts K3xxxx

Digital Keypad Introduction

duplex communication (with handset) hands-free talking simplex communication can be activated standard 4 (up to 2 from front-door stations)

INSTALLATION & OPERATING INSTRUCTIONS

BA505C 2-wire 4/20mA manual setpoint station Issue 6

INSTALLATION INSTRUCTIONS

Mounting and Operating Instructions

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -...

DP2 DOOR PHONE. For Technical Assistance Please Phone: (07)

Model XAV2 & XAV2-LED System Installation

Display Panel BAT 100 LSN. en Operation Guide

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide

AGATA C200 UK A/200N TARGHA 200. Installation Manual AGATAKIT C 200 UK

Typ: CAS # GEV_1_fam_RZ_luensee_print.indd :53

CP150B Vandal & Weather Resistant Keypad Security Systems

RECTANGULAR LED 3060-L L L-8060

sky Instruction manual IVW2221 BRUsky-S version 1.0

WALL MOUNTED PANEL. SECTION 2G (Rev.E) SECTION CONTENTS. Download from Technical Manuals area. sec.2g SMYLE WALL-MOUNTED PANEL 2

Zartek. CDP-808 Two Button Wireless Intercom Installers Manual

IF-80x Outdoor Terminal

Weathersafe Vision. Installation & Operating Instructions

Switches and Indicators 84

Operating Instruction

DCS Infrared Transmitter. User Manual. Digital Conference System. Danish Interpretation Systems

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

Product information. video indoor station ecoos IVW

7 Day Programmable Room Thermostat

PTC/PT100 board 2.0 Option

DP2. Door Phone. For Technical Assistance call the Manufacturers direct ph AM - 5PM West Coast Pacific Time

Supplementary instructions. Plug connector Harting HAN 7D. For point level sensors. Document ID: 34456

Roto E-Tec. Electronic drive and control systems for windows and doors. Installation instructions for detachable miniature cable junctions

Video kit with 1 hands-free internal unit, surface-mounting. Video kit with 2 hands-free internal units, surface-mounting

2M IR Mini Dome Quick Installation Guide

Installing Keypad and Backplate

SERVICE MANUAL FOR MODEL WPP-531-X-ADA-STROBE WEATHERPROOF TELEPHONE WITH OPTIONAL STROBE FEATURE. EQUIPPED WITH SPK1.

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

Wireless 7 Day Programmable Room Thermostat

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

DAC LIMITED. USER GUIDE Vandal Resistant Telephones 711 Autodial Telephone range

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

Model No. ET-JPF200BE

7 Day Digital Programmer 1 Channel Surface Mount

7 Day Digital Programmer 2 Channel Surface Mount

RCD Fused Connection Unit Model: RCD10WPV. RCD Double Sockets Models: RCD05WAV, RCD06WPV, RCD07MAV, RCD08MPV. Installation & Operating Instructions

Transparent Covers for Rail-Mounted Terminal Blocks, Usable with Lead Seals Description and Handling

SolConeX Wall-Mounted Socket, 16 A

SPARE PARTS & HOW TO HANDLE. μ-icc 2.45 compact. - Instructions - S/N: A01-PG10-SPE Version No.: 0 V

Outdoor PTZ. Mounting on the Ceiling Using Pendant Mount. Installation Guide. For Models: I93, I94, I95, I96, KCM /12/03

WIRED REMOTE INSTALLATION GUIDE

Megatouch FORCE Monitor Chassis Board Replacement

DP4 DOOR PHONE. For Technical Assistance Please Phone: (07)

PS 150 SINGLE CHANNEL TELEPHONE INTERFACE. USER MANUAL August 2016

sonnen Installation Practical

MCS 50. Discussion Control Unit. 1 of 7

GUARD CENTURION OPERATING INSTRUCTIONS THE AUTOMATIC CHOICE

SN Series - Part Numbering

Advanced Visual Solutions Ltd

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT

232iLM Keypad Installation and Programming Instructions

584 5WG AB_1 DELTA

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

INSTALLATION INSTRUCTIONS

smartentry Wireless Video Doorphone User Manual

IGLOO IGLOO EASY INSTRUCTION MANUAL

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

IGLOO IGLOO EASY INSTRUCTION MANUAL

B&W RearView Camera Installation & Operation

Operating Instructions VEGAMET 381

All in One Multi-purpose Cable Tester and Cable Tracer

INSTALLATION INSTRUCTIONS

PTZ Dome Network Camera Hardware User Manual

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Removal and Installation8

Warning Before Installation. Package Contents EN - 1. Refer to your user's manual for the operating temperature.

DPC-D245 2-wire door station

ZAVIO Outdoor IR Mini Dome. Quick Installation Guide

Standard Strip Series

Art. 4KC/ G Audiokit with digital codelock

2-Wire Video Intercom System

Product and Function Description

AlphaStatus Room Status System Installation and Use Instructions for the RSS400 Series Room Stations and Optional Master Station(s)

PTC/PT100 board 2.0 Option

APPLICATION PROCEDURE HOUSING INSTALLATION AND EQUIPMENT LOCATION

Operation and Installation Manual

User Manual. Item no.: Otto Graf GmbH Carl-Zeiss-Str. 2-6 Tel.: +49(0) Kunststofferzeugnisse D Teningen Fax: +49(0)

Combination Display Lights

Operating instructions. Switching amplifier DN0210 DN / / 2015

GSV-1A4 M12/2 M12/2. Highlights

Operating instructions. Speed monitor D / / 2014

Supplementary operating instructions for your air curtain system Controller TMC 500

CONEC Industrial Ethernet Circular Sealed RJ45 Connector System consists of a RJ45 Plug Kit, a Receptacle Kit and a Protective Cover Assembly.

E1135C PDU and Pod Upgrade Procedure

SENC 150 REFERENCE MANUAL

PUSH BUTTON PANEL. SECTION 3A (Rev. B) SECTION CONTENTS. Download from Technical Manuals area. sec.3a

2400W PIR Light Controller

SK CU4-PNT-C Part number:

Transcription:

Product information Front-door station series for surface-mounting Profi-Economic PES Profi-Design PDS

PI_GB_PES_PDS_Art0015689_1v0.doc 2 10/2005 In Table of contents Scope of delivery...3 Safety notices...3 General notes on the cabling in TCS audio systems...4 Device overview...5 Technical data...5 Application...6 Brief description...6 Basic functions...6 Additional functions...6 Assembly...7 Cable connection...8 General notes...8 Connection...8 2-wire special...8 Wiring example...8 Commissioning...9 Microphone and loudspeaker volume setup...9 Nameplate labelling...9 Programming of bell buttons...10 Basic principle...10 Programming with the Service Device...10 Programming steps legend...10 Programming state of a bell button...11 Testing...11 Deleting the...11 Programming a bell button...12 Method 1: In-house station not accessible...12 Programming the other bell buttons:...12 Method 2: In-house station accessible...13 Programming the other bell buttons:...13 Programming an already programmed bell button...14 Basic principle...14 Method 1: In-house station not accessible...14 Programming the other already programmed bell buttons...14 Method 2: In-house station accessible...15 Programming the other already programmed bell buttons...15 Note...15 Repair...16 Replacing the EEPROM memory...16 Cleaning...16 Service...16

PI_GB_PES_PDS_Art0015689_1v0.doc 3 10/2005 1 x PES / PDS 1 x hexagonal angle screwdriver DIN 911 1 x screwdriver with round handle nameplates, empty and with light symbol product information Scope of delivery Safety notices! Assembly, installation, and commissioning must only be carried out by a qualified electrician! For work on systems with 230 V AC mains current the safety requirements of DIN VDE 0100 must be observed. When installing TCS:BUS systems the general safety rules for telecommunication systems in accordance with VDE 0800 must be observed: separate cabling for high and low voltage lines, minimum distance of 10 cm for joint cabling arrangements, use of separators between high and low voltage lines in joint cable ducts, use of standard telecommunication cables, e. g. J-Y (St) Y with 0.8 mm² cross section, existing cables (rationalisation) with different cross sections may be used whilst taking account of the loop resistance.! Suitable lightning protection must ensure that a voltage of 32 V DC will not be exceeded at the TCS:BUS wires a and b.

PI_GB_PES_PDS_Art0015689_1v0.doc 4 10/2005 General notes on the cabling in TCS audio systems The cabling depends on the building situation and is only limited by its length. When selecting the cable length consider: the loop resistance must not exceed max. 20 Ω (table) To keep within the max. permissible loop resistance the wire cross section can be doubled, i.e. two lines are used for one wire (figure). The lines must be twisted. When using screened cables: connect the screens to each other and connect on one side to earth (b wire) on the power supply unit Choice of line or star wiring rt = red gn = green bl = blue br = brown ws = white sw = black ge = yellow Table: loop resistances Cable length in m Cable cross section 0.6 mm² 0.8 mm² Loop resistance in Ω 10 1.22 0.69 20 2.45 1.38 30 3.67 2.07 40 4.90 2.76 50 6.12 3.44 60 7.35 4.13 70 8.57 4.82 80 9.80 5.51 90 11.02 6.20 100 12.24 6.89 150 18.37 10.33 200 24.49 13.78 250 17.22 300 20.66

PI_GB_PES_PDS_Art0015689_1v0.doc 5 10/2005 Device overview microphone loudspeaker connection for bell button extension loudspeaker volume control loudspeaker cover EEPROM connection terminal Jumper PES board microphone volume control cable duct attachment holes 1, 2 bell button lower panel Shown is the PES12 without name plate glass attachment holes 3, 4 condensate drainage Technical data Supply voltage: + 24 V + 8 % (via power supply and control unit) Case: aluminium, anodised Name plate glass: plexiglass Operating temperature range: -20 C to 50 C Input current: I(a) = 0.4 ma, I(P) = 16 ma standby Maximum input current: I(Pmax) = 65 ma

PI_GB_PES_PDS_Art0015689_1v0.doc 6 10/2005 Application The PES / PDS are front-door stations for exterior use. They are suitable for surface mounting. Brief description Basic functions Bell buttons Saving the bell button allocations in the front-door station Operating a programmed bell button triggers a ringing tone at the in-house station. Operating an unprogrammed bell button triggers the light switch function in the power supply and control unit. When operating a bell button an acknowledgement tone sounds. All programmed data (serial numbers and parameters) are stored in the EEPROM. If the front-door station requires replacement, the EEPROM board can be removed from the programmed front-door station and inserted into the new front-door station of identical design. Additional functions Name plate illumination connection Allocation of serial number to bell buttons additional switching signal via LED, P-wire connection required. for Service Device for PES / PDS: for connection of a bell button extension PET / PDS. 2 use a combining device BRE2.

PI_GB_PES_PDS_Art0015689_1v0.doc 7 10/2005 Assembly 1. Opening the case The lower panel is attached to the aluminium profile by two hexagon socket screws. (1) Unscrew both screws using an Allen key only half way: (2) Turn the lower panel to the left, without removing it completely. (3) Slide the name plate glass fully down. 2. Feed the cables through the cable duct. 3. Attach the device safely to the wall from the attachment holes (see overview) using suitable screws. Take care not to pinch the cables under the spacers on the device back. 4. Closing the housing Slide the name plate glass upwards under the front panel. Turn the lower panel to the right until the recess fits over the screw. Tighten the screws.! When sliding the name plate glass upwards take care not to damage the rubber seals in the guide grooves. When fitting additional devices make sure that you can slide the name plate glass of the device downwards out of the profile. Do not fit a device below the device.! Never seal the device using silicon! Condensate must be allowed to drain and evaporate.

PI_GB_PES_PDS_Art0015689_1v0.doc 8 10/2005 General notes Cable connection Use the small screwdriver supplied to connect the lines and prevent damage to the device.! Please note the lines should not be run in front of the LED to prevent obstruction of the nameplate illumination the lines must not be squeezed below the spacers on the back of the front-station. Connection 1. Strip the insulation from the line ends. 2. Connect the lines, depending on system type, in accordance with the connection diagram. 2-wire special In this only one front-door station can be connected! A P-wire has to be made by bridging terminals a and P. Note: The front-station does not work if the bridge is connected to b instead of a. Wiring example To connect a door release relay use the R terminal. A door release contact can be connected to the S terminal. This allows for checking whether the triggered door is open or closed.

PI_GB_PES_PDS_Art0015689_1v0.doc 9 10/2005 Commissioning Fully install the devices of the system. Check the a and b wires for short circuits. Connect the power supply and control units to the mains voltage. Switch on the mains supply. Microphone and loudspeaker volume setup! For adjustments use the small screwdriver supplied! The volumes have been set to an average value at factory. A modification may not always be necessary. When adjusting please note: The amplification of loudspeaker and microphone cannot be set independently from each other. Too great volume will cause a feedback effect (whistling). microphone In-house station volume adjustment Volume control loudspeaker Front-door station volume adjustment Nameplate labelling The templates are available on our website www.tcs-germany.com \ English\ Downloads \ System and technology basics\ Product installation and use \ labelling of the nameplate 1. Enter the desired name into the template. 2. Print the name plate on the special film* and cut it to size. 3. Loosen the pockets at the outer edge of the name plate glass using the insertion aid supplied. 4. Insert the cut plates from the side into the pockets on the name plate glass. * We recommend to print the name plates on a durable special film. The film can be ordered directly from TCS: Writable polyester film for name plates DIN A4.

PI_GB_PES_PDS_Art0015689_1v0.doc 10 10/2005 Programming of bell buttons Basic principle All devices at the TCS:BUS have a unique serial number. During this serial number is transferred to the front-door station and linked to the bell button. Programming with the Service Device Utilise the simple 1 person with the TCS Service Device. You will not need access to the in-house stations in the flats. The voltage supply is provided by connecting the Service Device to the TCS:BUS. For more on the TCS Service Sevice see: www.tcsgermany.de If you do not have the Service Device, you can also program manually. Programming steps legend briefly press key press key until release key continue wait until Delation tone LED flashes slowly LED flashes rapidly NoProg tone ring tone Prog2 tone Progsperr tone

PI_GB_PES_PDS_Art0015689_1v0.doc 11 10/2005 Programming state of a bell button The front-door stations are supplied un-programmed. The state can be checked as follows: Testing press briefly Noprog tone ring tone bell button un-programmed bell button programmed Before a pre-programmed bell button can be re-programmed, the must be deleted. Deleting the 1 2 LED flashes switched on 3 Press deletion tone release until sounds 1), bell button deleted switched off LED flashes no more 1) If Progsperr ton sounds the block is active. It can be removed by the service device TCSK-01 only.

PI_GB_PES_PDS_Art0015689_1v0.doc 12 10/2005 Programming a bell button Connect the in-house station to the TCS:BUS. Use one of these two methods. Method 1: In-house station not accessible 1 LED illuminates switched on 2 LED flashes 3 Floor-switch button within 3 sec: press 1 sec, until bell rings - release - press 1 sec until bell rings - release. bell button programmed 4 ring tone sounds at front-door and in-house station 1) switched off LED illuminates Programming the other bell buttons: Step 1 repeat steps 2 and 3 each time complete the of all buttons with step 4

PI_GB_PES_PDS_Art0015689_1v0.doc 13 10/2005 Method 2: In-house station accessible 1 LED illuminates switched on 2 LED flashes bell button programmed Lift handset press briefly, replace handset at in-house station ring tone sounds at in-house station at front-door and in-house station 1). 3 switched off LED illuminates Programming the other bell buttons: Step 1 repeat step 2 each time for additional bell buttons where necessary complete the of all buttons with step 3

PI_GB_PES_PDS_Art0015689_1v0.doc 14 10/2005 Programming an already programmed bell button Basic principle A bell button can be linked to two serial numbers (of two in-house stations). It is then possible to have two different in-house stations ring at the same time. Connect the in-house stations to the TCS:BUS. Use one of these two methods. Method 1: In-house station not accessible 1 LED illuminates switched on 2 LED flashes 3 Floor-switch button within 3 sec: press 1 sec, until bell rings - release - press 1 sec until bell rings - release. bell button programmed Press... and... and ring tone sounds release until Noprog tone at front-door and Prog2 tone sounds 1)... sounds in-house station. 4 LED illuminates switched off Programming the other already programmed bell buttons Step 1 repeat steps 2 and 3 each time complete the of all buttons with step 4

PI_GB_PES_PDS_Art0015689_1v0.doc 15 10/2005 Method 2: In-house station accessible 1 LED illuminates LED flashes 2 1st person 2nd person 1st person switched on bell button programmed Lift handset Press until...and... and ring tone release replace at the Prog2 tone Noprog tone sounds at handset in-house sounds 1) sounds front-door and at in-house station. in-house station. station. 3 switched off press briefly LED illuminates Programming the other already programmed bell buttons Step 1 repeat step 2 each time for additional bell buttons where necessary complete the of all buttons with step 3 Note Repeated of an already programmed bell button always only changes the second serial number. If you want to change the first programmed serial number, you have to delete both serial numbers and then re-program both serial numbers.

PI_GB_PES_PDS_Art0015689_1v0.doc 16 10/2005 Repair Replacing the EEPROM memory All programmed data, like serial numbers and parameters, are stored in the EEPROM. If the front-door station requires replacement, the EEPROM board can be removed from the programmed front-door station and inserted into the new front-door station of identical design. Open the case. Pull the small PCB off the electronic board. Plug the EEPROM board onto the pins in the new un-programmed front-door station. Take care that all four poles of the plug are inserted into the jack of the small PCB and that the component side is visible. After replacement all is available again. Cleaning! Avoid water entering the device! Do not use any aggressive or abrasive cleaning agents! Clean the device using a dry or slightly moist cloth. More persistent dirt can be removed using a mild household cleaner. Service Contact your local sales representative or www.tcs-germany.com