Requirements for machine approval in North America under the new NEC 2017

Similar documents
Technical System Catalog RiLine and Maxi-PLS

RiLine Compact The smart power distribution system

UL 508 A standard-compliant design of industrial control panel

System solutions for your energy requirements

UL508Afor Panel Builders Getting Started

RiLine Compact The smart power distribution system

RiLine Compact The smart power distribution system

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

UL 508A Industrial Control Panels Eaton. All Rights Reserved.

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60

Equipment Short-Circuit Current Rating and Available Fault Current

Applying branch circuit breakers and supplementary protectors in North America

Industrial Control Panels Tested product combinations to meet NEC Article 409 and UL 508A Standard

Applying branch circuit breakers and supplementary protectors in North America

Spacing Requirements for Power Distribution and Terminal Blocks

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

IEC An introduction. 28 March 2012 By Craig McKee Technical Manager

Adaptors Busplug Low Voltage Switchboard Equipment

Application Instantaneous release response current 5-10 x In. Switching capacity Switching Capacity 15 ka (IEC/EN ) U e V AC 230/400

Industrial Control Panels for North America

140M C 2 E A63 KN CC GJ

Problem solver for the North American market: PKZM4-...-CB

Miniaturecircuitbreaker(MCB),16A,3p,B-Char,AC. Application Switchgear for industrial and advanced commercial applications.

For Sales and Support call KMParts.com (866)

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

Understanding SCCR. THE BEST ELECTRICAL CONTROLS BUSINESS ON THE PLANET! Unmatched Service Superior Product Quality Advantage Pricing

Circuit Protection Methods

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

E A54-UL 2012-AUGUST-29 XP POWER L L C SUITE E DYER RD SANTA ANA CA 92705

60103 Circuit Breaker

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

Cat. No. 140M-F M-D8E-B

Max. Short Circuit Current [ka] Standard Motor Protection High Inrush Motor Protection Motor Circuit Protection 600V C-Frame

Short Circuit Current Ratings and AC Drives

SENTRON. Protective devices Selectivity for 3VA molded case circuit breakers. Introduction. Selectivity - terms and definitions

140M C 2 N A63 KN CC GJ

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

SECTION (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Miniature Circuit Breakers for Railway Applications

Smart Monitoring System compact, secure, efficient

UL 489 DIN Rail Miniature Circuit Breakers

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

Fast Bus Fast Bus Busbar System

UL 489 DIN Rail Miniature Circuit Breakers

Fast Bus Busbar System

Switch Disconnectors, Main and EMERGENCY-STOP Switches

UL TEST REPORT AND PROCEDURE

Protection Equipment

C E R T I F I C A T E O F C O M P L I A N C E

Complete UL/CSA Disconnect Switch Kits

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Bulletin 194R Fused and Non-Fused Disconnects Product Selection

Operating instructions. Standstill monitor A / / 2011

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

Bulletin 194R Fused and Non-Fused Disconnects Product Selection

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

Miniature Circuit Breakers and Supplementary Protectors. Contents

Solid-State Switching Devices

DIVISION 16 SECTION Surge Protective Device Submittal (SPD)

5/2 Product overview. 5/3 Distribution board components. 5/9 Built-in components. 5/17 Mounting components 5. Siemens ET B1 10/2009

GENERAL UL th EDITION BID SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.

3RV1 Circuit-Breakers

Load Feeders, Motor Starters and Soft Starters

SERIES RATED COMBINATIONS

SRI LANKA STANDARD CODE OF PRACTICE FOR GRID CONNECTED PHOTOVOLTAIC POWER SYSTEMS SLS 1522:2016

TeSys IEC Contactors and Overload Relays

Designing with Thermally Protected TCMOV Varistors for Type 1 and Type 2 UL1449 3rd Edition Applications

Allen-Bradley Bulletin 100 Contactors

Siemens AG RA6 Fuseless Compact Starters. Catalog News LV 1 N April 2008 SIRIUS.

Electrical Service Change-Tn Neenah

UL TEST REPORT AND PROCEDURE

White Paper October 2009

IEC H.P. Rated Pin and Sleeve Sequential contacts engagement during mating and un-mating IEC configurations specific to each voltage and

1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers

US Catalog July 2016 SMISSLINE TP

UL TEST REPORT AND PROCEDURE

SECTION OVERCURRENT PROTECTIVE DEVICE COORDINATION STUDY

UL TEST REPORT AND PROCEDURE

Disconnect Switches. Safe Switching and Disconnecting

Standards and approvals

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

UL 489 Cable-In / Cable-Out Branch Circuit Breaker

Cutler-Hammer. January 2001

Zener Barriers Bulletin 937Z

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

Industrial Controls Product Catalog RA64 / 3RA65 up to 32 A for mounting rail, surface,

SECTION DISCONNECT SWITCHES

Model KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

File E28476 Project 01ME June 27, 2001 REPORT COMPONENT - CONNECTORS FOR USE IN DATA, SIGNAL, CONTROL AND POWER APPLICATIONS

MEDIUM VOLTAGE PRODUCTS. UniSec Air-insulated medium voltage secondary distribution switchgear Informed choice for safety

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

4 COMBINATION SIRIUS. SIRIUS 3RA6 Compact Starters 4/2. General data

MOTOR PROTECTION CIRCUIT BREAKERS

UL TEST REPORT AND PROCEDURE

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Air-insulated medium-voltage secondary distribution switchgear

Transcription:

Requirements for machine approval in North America under the new NEC 2017

2 Rittal NEC 2017

The NEC 2017 introduces increased requirements for SCCR Rittal has long been prepared Rittal always responds promptly to the latest international requirements with suitably adapted, standard-compliant products and up-to-date knowledge for seamless compliance with the latest standards in enclosure manufacturing. SCCR ratings of up to 65 ka are anticipated Surveys show that more than half of all machine manufacturers design their products for the North American market with the minimum SCCR (Short Circuit Current Rating) of 5 ka. Publication of the NEC 2017 means there is a greater risk that these types of machines will no longer comply with the new code and therefore will not be approved. Rittal offers a reliable solution to this problem with the RiLine 60 mm busbar system. It has culus-listed approval with a consistent SCCR of 65 kw. Approval offers decisive advantages for machinery and plant manufacturers with target markets in the USA or Canada: Minimal design input, simplified plant sign-off by UL (Underwriters Laboratories) and CSA (Canadian Standards Association), and most importantly, there is no need to test for compliance with the Conditions of Acceptability (COA) of all UL-recognized components used. A source of practical knowledge: The Rittal seminar on switchgear and control cabinets for North America Rittal technical seminars are well-known for their topicality, and their focus on enabling participants to quickly translate knowledge into practice. Market segment IEC/UL Market segment IEC Market segment UL Rittal NEC 2017

Requirement for machine approvals in the USA and Canada Compliance with UL 508A In the USA and Canada, a machine or plant cannot be commissioned until approved by the AHJ (Authority Having Jurisdiction). The AHJ verifies compliance with the valid regulations in that state, such as the National Electric Code NEC (NFPA 70) or the NFPA 79 Electrical Standard for Industrial Machinery. In practice, approval of the equipment to standard UL 508A provides the required verification. Without verification, the AHJ will not usually issue an operating permit. UL 508A combines the applicable requirements from the NEPA codes into a product standard for enclosures, compliance with which assures the machine or plant manufacturer that the superordinate requirements of the NFPA have been met. A UL 508A certificate is generally accepted by an AHJ as evidence of compliance. NEC The area outlined in green identifies the area of application of the NEC. The NEC (also published as NFPA 70) is revised by NFPA every three years, and as the National Electric Code, stipulates the fundamental requirements for electrical installations. 4 Rittal NEC 2017

All components used in the enclosure, including the climate control and the housing, must have suitable UL approval. UL 508A The area outlined in magenta specifically considers the requirements of UL 508A for electrical control cabinets. The method outlined in Annex SB is a recognised procedure for determining the SCCR, whose importance is growing with the NEC 2017. NEC 2017 requirement for short-circuit withstand strength of enclosures at the infeed point The system s SCCR must be greater than or equal to the SCCR at the supply end. National Fire Protection Association NFPA 79 applies to the area marked in blue. It outlines the requirements governing the electrical equipment of machines. Rittal NEC 2017 5

SCCR under UL 508A Fundamental principles Key terms and regulations When determining the SCCR, for example in conjunction with the use of busbars, first of all it is important to be familiar with the commonly used components, terms and regulations. The following sections therefore address these framework parameters, with reference to Standard UL 508A Second Edition, including revisions, dated July 1, 2017. SCCR terminology Feeder Circuit The feeder circuit is subject to increased requirements on creepage distances and clearances. The feeder circuit includes all devices which, viewed from the load side, are positioned after the last Branch Circuit Protective Device (BCPD). Branch Circuit There are no increased requirements on branch circuits with regard to creepage distances and clearances. Viewed from the load side, the branch circuit extends as far as the fi rst Branch Circuit Protective Device (BCPD). SCCR The Short Circuit Current Rating refers to the short-circuit withstand strength of a component, distributor, system, machine or device. Reference is often made to an overall SCCR for enclosures. As a minimum requirement, this fi gure must comply with the short- circuit rating of the supply. BCPD Branch Circuit Protective Devices include fuses to UL 248, circuit-breakers to UL 489, and manual and combination motor controllers type E/F to UL 508. They perform protective functions with regard to overcurrent, short-circuit and earth fault protection and must be approved to a suitable standard. In terms of load, the most recent BCPD represents the boundary between the feeder and branch circuit. CCN The Category Control Number classifi es devices and components into categories. Which categories may be used in the application are defi ned, for example, in UL 508A under Table SA1.1. I p The peak let-through is the maximum current which a currentlimiting device will allow through, in relation to a defi ned SCCR. SCPD A Short Circuit Protective Device can be used to increase the SCCR under certain conditions. Key and common devices for busbar systems Device name (IEC) Device name (UL) UL Category Control Number (CCN) IEC Symbol UL Circuit-breaker Circuit breaker, Moulded Case and Circuit Breaker Enclosures DIVQ 1 Motor circuit-breaker Motor s, manual (Type E) NLRV Motor-starter combination s (Type F) NKJH 1 -K1 0 A 2 Fuse Cartridge Fuses, nonrenewable JDDZ 6 Rittal NEC 2017

SCCR regulations Which short circuit-limiting protective and switching devices SCPD can be used in the feeder circuit to increase the SCCR? Short circuit-limiting protective devices (hereinafter referred to as SCPD) may be used to increase the SCCR value of an enclosure. If the peak let-through of an SCPD (feeder fuse/feeder breaker) is less than the SCCR of the component in question in the branch circuit, the SCCR of this component may be raised to the feeder SCCR under consideration. The following components may be used as SCPD: I Circuit breaker, moulded case and circuit breaker enclosures current limiting Only MCCBs specifically labelled as current limiting may be used, because the currentlimiting function must be part of the approval. This current-limiting property must be verified at regular intervals by the manufacturer. II Cartridge fuses Here too, the manufacturer must provide regular verification of the let-through values. For example, the fuse type must be a fuse class CC, class J... listed under UL 248. The let-through values (I p) shown in Table SB4.2 of UL 508A apply. In this connection, it is important to note that the selected current-limiting protective device (SCPD) may only be used to increase the SCCR of components in the branch circuit. The SCCR of components in the feed circuit cannot be improved. The following components may be used as BCPD: I Fuse with UL Category Control Number JDDZ II Circuit breaker, moulded case circuit breaker enclosures with UL Category Control Number DIVQ III Manual Motor with UL Category Control Number NLRV IV with UL Category Control Number NKJH Use of a Serial Rating A serial rating cannot be applied to any combination of a current-limiting device with another device, such as a contactor. These untested combinations are not a combination motor controller as defined in UL 508A. A serial rating of two or more devices must be tested in this combination, and can only be used to increase the SCCR in this exact combination of devices. If no serial rating exists for this combination, the lowest SCCR of one of the two individual devices applies. What is a high fault SCCR? A High Fault Short Circuit Rating is the SCCR specified on or in the device documentation, and is greater than the Standard Fault Short Circuit Current Rating to UL 508A, Table SB 4.1. Compliance with the High Fault SCCR may be conditional upon a current-limiting protective device being positioned upstream of the components or system. Rittal NEC 2017 7

Important for UL 508A: Short-circuit withstand strength SCCR to the lowest common denominator Determining the overall SCCR in the enclosure When determining the SCCR (Short Circuit Current Rating), it is a matter of determining which components or tested combinations in the main circuits inside the enclosure have the lowest SCCR. The lowest individual SCCR determines the SCCR of the overall enclosure (overall SCCR). An enclosure s SCCR ultimately determines whether the application s short-circuit withstand strength requirements match the available SCCR from the power supply. This usually affects power circuits. With control circuits, it is not necessary to determine the SCCR, because transformers are usually connected upstream. To calculate the overall SCCR of an enclosure, the planner must consider the SCCR value of each individual component and device from the load side through to the feed-in point. Plan ahead, ensure a high level of efficiency The overall SCCR should be taken into account at the planning stage, since by selecting correct components and devices, and also by using suitable application techniques for short circuit current-limiting devices, it is usually possible to achieve a cost-effective solution with the required SCCR. Considering the SCCR at a later date, for example at the time of commissioning, could lead to higher material and modification expenses if it fails to meet the requirements, causing costs to rise exponentially. The verification procedure as set out in the SB supplement to UL 508A The NEC offers two verification options. Firstly, by having the system tested to a recognised verification procedure such as that set out in the SB supplement to UL 508A. As testing is always timeconsuming, as well as incurring significant material and personnel costs, this verification procedure has emerged as an important tool. 8 Rittal NEC 2017

Diagrammatic procedure for determining the overall SCCR of an enclosure to UL 508A SB4.2 Ascertain the SCCR of the individual components in the power circuit 4.2.1 List of devices that do not fall under the SCCR approach 4.2.2 a) Determining the SCCR using the rating plate or manufacturer documentation of the device/component 4.2.2 b) Determining the SCCR in accordance with Table SB4.1 4.2.2 c) Determining the SCCR by testing to UL 508 SB4. Ascertain the feeder components that may be used to limit the short-circuit. 4..1 Short circuit current-limiting with a transformer in the feeder 4..2 Increasing the SCCR by using a current-limiting circuit-breaker in the feeder 4.. Increasing the SCCR by using current- limiting fuses in the feeder SB4.4 Determine the overall SCCR of the enclosure 4.4.1 Determining the smallest SCCR of all power circuits including a control current protective device 4.4.4 a) For enclosures with only one power circuit and no outgoing protective device (BCPD) within the enclosure 4.4.4 a) For enclosures with only one power circuit and an outgoing protective device (BCPD) within the enclosure Further information on calculation of the SCCR can be found in the SB Supplement to UL 508A. 4.4.4 c) For enclosures with multiple outgoing circuits and feeder components such as circuit-breaker, disconnecting switch, busbar system, terminal blocks, overcurrent protective devices Rittal NEC 2017 9

SCCR under UL 508A Practical example SCCR including a busbar assembly Busbars are a standard feature in modern enclosure assembly. RiLine systems are all tested for an SCCR of 65 ka. This therefore eliminates the need for time-consuming verification. The user need only be concerned with SCCR compliance by the top-mounted equipment. Here is an example of SCCR in busbar systems. 10 Rittal NEC 2017

SCCR in a busbar assembly SV 940.050 65 ka, V with circuit breaker CCN: DIVQ max. 600 A SV 945.710 65 ka, V with circuit breaker CCN: DIVQ max. 600 A SV 942.510 65 ka, V with circuit breaker CCN: DIVQ max. 125 A SV 940.10 65 ka, V with manual motor controller CCN: NLRV max. 0 A SV 940.90 65 ka, V with manual motor controller CCN: NKJH max. 0 A SV 940.10 65 ka, V with Class CC fuseholder CCN: JDDZ max. 0 A Feeder Circuit 1 1 DIVQ 600 A DIVQ 125 A NLRV 0 A 2 NKJH 2 0 A 1 2 JDDZ 0 A BCPD 1 2 Branch Circuit 65 ka tested M +PE M +PE Load Rittal NEC 2017 11

All RiLine systems have been tested for an SCCR of 65 ka. This therefore eliminates the need for time-consuming verification. The user need only be concerned with SCCR compliance by the top-mounted equipment. 12 Rittal NEC 2017

UL-tested Rittal components RiLine busbars Ideal for international use with an approved, culus listed 60 mm busbar system. The RiLine 60 mm busbar system from Rittal has culus-listed approval. This approval offers clear advantages for international machinery and plant manufacturers with target markets in the USA or Canada: Minimal design input, simplified sign-off of plant by UL (Underwriters Laboratories) and CSA (Canadian Standards Association), and therefore most importantly, no need to test for compliance with the Conditions of Acceptability (COA) of all the UL-recognized components used. Consistently tested for an SCCR of 65 ka In order to provide effective support for use of the RiLine busbar technology in enclosures, Rittal has conducted comprehensive testing of all RiLine busbar systems and components, and generated a uniform SCCR of 65 ka. Users benefit when planning and designing enclosures to UL 508A, because prescribed measures allow simple, time-saving design of the busbar systems and components. They must only ensure that the top-mounted equipment used such as circuit-breakers, motor circuit-breakers and fuses meet the specified requirements. Tables are included in the Appendix for this purpose, and clearly define the measures needed to meet this condition. Our expertise your benefit. Simple and fast With a clear tabular layout and uniform SCCR Effective Clear, consistent representation of the SCCR; identical SCCR for every component Efficient No additional effort needed to increase the SCCR in various applications Rittal NEC 2017 1

RiLine busbars Excerpt Initial overview of UL 508A-compliant RiLine busbars and components The following table lists all the key products covered by the 65 ka SCCR, but does not include all UL-listed items from the RiLine product range. SCCR overview of RiLine UL busbar systems and components in compliance with UL 508A Model No. Code Flat copper bar system 940.050 940.004 Busbar support (UL), -pole, 60 mm Centre-to-centre spacing, for E-Cu 15 x 5 0 x 10 mm PLS 800 busbar system Busbar support PLS 800 (UL), -pole, 941.050 60 mm centre-to-centre spacing PLS 1600 busbar system Busbar support PLS 1600, -pole, 942.050 60 mm centre-to-centre spacing Busbar support PLS 1600 PLUS, 4-pole, 942.004 60 mm centre-to-centre spacing OM adaptor 940.760 940.780 940.10 940.20 940.40 940.70 OM adaptor, AWG 12, -pole, W = 45 mm OM adaptor, AWG 12, -pole, W = 45 mm 940.400 OM adaptor, AWG 12, -pole, W = 90 mm 940.50 940.80 940.90 940.770 940.460 940.470 940.720 940.70 940.740 940.750 OM adaptor, AWG 10, -pole, W = 45 mm OM adaptor, AWG 10, -pole, W = 55 mm OM adaptor, AWG 8, -pole, W = 55 mm 940.710 OM adaptor, AWG 8, -pole, W = 75 mm 940.410 940.40 940.450 OM adaptor, AWG 6, -pole, W = 55 mm 940.700 OM adaptor, AWG 6, -pole, W = 75 mm SCCR (Short Circuit Current Rating) ka 65 65 65 65 Rated voltage V AC SCPD (Short Circuit Protective Device) Type SCPD rating max. A CCN (Category Control Number) Circuit breaker 600 DIVQ 600 Fuse Class L 800 JDDZ Circuit breaker 600 DIVQ 600 Fuse Class J 600 JDDZ Busbar dimensions W x H mm Distance between busbar supports mm 0 x 5/10 250 PLS 800 150 600 Fuse Class L 1400 250 JDDZ 600 Fuse Class L 1600 100 PLS 1600 Circuit breaker 1200 DIVQ 250 600 Fuse Class J 0 JDDZ 2 NKJH 600 Fuse Class J 0 JDDZ 2 NKJH 600 Fuse Class J 0 NLRV Manual Motor 2 NKJH 600 Fuse Class J 0 JDDZ 2 NKJH 600 Fuse Class J 0 NLRV Manual Motor 2 NKJH 600 Fuse Class J 60 JDDZ Manual Motor 6 NLRV NKJH 600 Fuse Class J 60 JDDZ Manual Motor 6 NLRV NKJH 600 Fuse Class J 60 JDDZ Manual Motor 6 NLRV NKJH 600 Fuse Class J 60 JDDZ Manual Motor 6 NLRV NKJH 0 x 5/10 PLS 800 PLS 1600 250 14 Rittal NEC 2017

Further details can be found at www.rittal.com For reasons of simplicity, other tested short-circuit values and accessory components such as covers, base trays, busbars etc. are not shown here. This information can be viewed in Rittal UL-File E191125 or on the relevant product pages of our website, or in the online certificate for UL-File E191125. Model No. Code SCCR (Short Circuit Current Rating) ka Rated voltage V AC SCPD (Short Circuit Protective Device) Type SCPD rating max. A CCN (Category Control Number) Busbar dimensions W x H mm Distance between busbar supports mm Busbar connection adaptors 942.200 942.210 Busbar connection adaptor 6 A, -pole 600 Fuse Class J 60 JDDZ Manual Motor 65 NLRV 942.240 Busbar connection adaptor 125 A, -pole 600 Fuse Class J 400 JDDZ Circuit breaker 125 DIVQ 942.224 Busbar connection adaptor 125 A, 4-pole 600 Fuse Class J 400 JDDZ Circuit breaker 125 DIVQ 942.250 942.270 Busbar connection adaptor 250 A, -pole 600 Fuse Class J 400 JDDZ Circuit breaker 250 DIVQ 942.254 Busbar connection adaptor 250 A, 4-pole 600 Fuse Class J 400 JDDZ Circuit breaker 250 DIVQ 942.11 Busbar connection adaptor 800 A, 1-pole 942.10 Busbar connection adaptor 800 A ( x 1-pole), cable outlet at the top/bottom (60 mm) 65 600 Fuse Class L 800 JDDZ Circuit breaker 600 DIVQ 600 Fuse Class L 800 JDDZ Circuit breaker 600 DIVQ 12 x 5 0 x 10 PLS 800 PLS 1600 250 942.14 Busbar connection adaptor 800 A, add-on kit for SV 942.10 (4-pole layout) 600 Fuse Class L 800 JDDZ Circuit breaker 600 DIVQ 942.290 942.00 Busbar connection adaptor 800 A, -pole 600 Fuse Class L 800 JDDZ Circuit breaker 600 DIVQ 942.21 Connection block 1600 A, 1-pole 600 Fuse Class L 1600 JDDZ Circuit breaker 1200 DIVQ 942.20 Busbar connection adaptor 1600 A ( x 1-pole), cable outlet at the top/bottom (60 mm) 600 Fuse Class L 1600 JDDZ Circuit breaker 1200 DIVQ 942.24 Busbar connection adaptor 1600 A, add-on kit for SV 942.20 (4-pole layout) 600 Fuse Class L 1600 JDDZ Circuit breaker 1200 DIVQ Circuit-breaker component adaptors 942.400 942.410 942.540 942.550 942.504 942.514 942.610 945.604 945.614 945.720 945.70 945.700 945.710 Circuit-breaker component adaptor 100 A, -pole Circuit-breaker component adaptor 125 A, -pole Circuit-breaker component adaptor 125 A, 4-pole Circuit-breaker component adaptor 250 A, -pole Circuit-breaker component adaptor 250 A, 4-pole Circuit-breaker component adaptor 400 A, -pole Circuit-breaker component adaptor 60 A, -pole Fuse holder 945.100 Fuseholder class J, 61 100 A, -pole (60 mm) 945.200 Fuseholder class J, 101 200 A, -pole (60 mm) 945.400 Fuseholder class J, 201 400 A, -pole (60 mm) Accessories 079.010 Universal support for laminated copper bars up to 2 x 6 x 10 mm 65 Manual Motor 100 NLRV Circuit breaker 100 600 Fuse Class J 125 250 400 600 100 200 400 DIVQ JDDZ 65 Circuit breaker 1200 DIVQ 0 x 5/10 PLS 800 PLS 1600 0 x 5/10 PLS 800 PLS 1600 2 x 6 x 10 mm lam. Cu 250 250 250 Rittal NEC 2017 15

Enclosures Power Distribution Climate Control IT Infrastructure Software & Services You can fi nd the contact details of all Rittal companies throughout the world here. XWW0019EN1708 www.rittal.com/contact