Leutron. Lightningand. Surge Protection for Power Net Systems (SPD) with EnerPro Combi-Devices. Seite 0 von14

Similar documents
Surge Protection Devices Ex9UE2

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection

Generator connection box Protection of inverter

Overvoltage Protection Devices

Overvoltage Protection Devices

Overvoltage Protection Devices

Overvoltage Protection Devices

TT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.:

Overvoltage Protection Devices

Lightning and Surge Arresters

VAL-CP-1S-175. Extract from the online catalog. Order No.:

PT 3-PB-ST. Extract from the online catalog. Order No.:

VAL-CP-3S-350. Extract from the online catalog. Order No.:

Technical features OVR Surge Protective Devices Type 1 & Type 1+2

ETITEC - Lightning and Surge Arresters

Surge protection for gutter heating systems

Surge protection for frequency converters

PT 2X2-24DC-ST. Extract from the online catalog. Order No.:

Single Pole SPD. Model V20/75-S V20/150-S V20/275-S V20/320-S V20/385-S V20/420-S V20/440-S V20/550-S EN/IEC / UL th

Surge & Filter Protection Addressing your industrial power quality needs.

Surge Protection Devices and Surge Protection Kit

STEP-PS/1AC/24DC/1.75

wietap wietap Overvoltage Protection Tensions running high

PRACTICAL EXAMPLES OF OVERVOLTAGE PROTECTION

PT 2-PE/S- 24AC-ST. Extract from the online catalog. Order No.:

NEW surge protective devices

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Lightning and Surge Protection of Photovoltaic Installations. Leutron GmbH 2013 Leinfelden-Echterdingen, Germany

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

R3&A Limited, Cobourg, ON

PHOENIX CONTACT - 01/2007

PT 2X2-HF-24 DC-ST. Extract from the online catalog. Order No.:

SPD Catalogue. SPD Catalogue. for AC applications

Extract from the online catalog SFP 1-5/120AC Commercial data Product description Technical data Standards

Increased Safety for Switchgear Cabinets CI Arresters with Integrated Backup Fuse

8 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA

Overvoltage Protection for low-voltage supplies

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

TT-2-PE-M-24DC. Extract from the online catalog. Order No.:

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters

MINI-PS AC/10-15DC/8

Building Surge Protection Information Pack

Lightning and Surge Arresters

PT 5-HF- 5 DC-ST. Extract from the online catalog. Order No.:

TT-2-PE- 24DC. Extract from the online catalog. Order No.:

Technical Data. Circuit Protection - Surge Protection Devices. Ver 1.0 CUSPD1110. Brief product description:

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Attachment plug with surge protection for coaxial signal interfaces. Connection: N connector, male/female

Electronic timer CT-ERS.21

SPM Series Plug-in Surge Protection

Electronic timer CT-ERD.12

POWER SUPPLY SYSTEMS SPDs for low-voltage installations and equipment

Installation / Control Technique

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

MODULES FOR SAFETY AND MONITORING

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

SPM Series. Plug-in Surge Protection

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Electronic timer CT-ARS.11

TT-UK5/ 24DC. Extract from the online catalog. Order No.:

MCF lightning arrestor

Autoprotected Surge Arresters New OVR Plus range

BLITZDUCTOR XTU Universal lightning current / surge arrester

Switching relay CT-IRE with 1 c/o (SPDT) contact

Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

Protection of PHOTOVOLTAIC SYSTEMS against LIGHTNING and OVERVOLTAGE. Surge Protection Device

PRF1 12.5r/PRF1 Master/ PRD1 25r/PRD1 Master Type 1 and 2 LV surge arresters

QUINT-PS/ 1AC/24DC/ 5

Lightning & Surge Protection for Wind Turbine Systems

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

Lightning Current Equipotential Bonding SPDs

Surge Protection Devices Type 1+2

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

TT-SLKK5/ 24DC. Extract from the online catalog. Order No.:

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

Micro Contactor MA Series

Boxed interface relays and optocouplers R600 Boxed slim relays, optocouplers and accessories

Electronic timer CT-AHD.22

ASI QUINT /2.4 EFD

Power Supply HARTING pcon

SURGE PROTECTOR. lighting. for.

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

INFORMATION TECHNOLOGY SYSTEMS SOCKET OUTLET. DSM (RJ45) Surge Arrester. LAN fine protection for fixed installation

Application-optimised DEHNshield Combined Arrester

Residual Current Devices. Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

SURGE PROTECTION LIGHTNING & EARTHING EQUIPMENT

3 Design of the electrical installation protection system

interface Overvoltage Protection

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact

Power Supply HARTING pcon

Remote contact signaling available. visual status indication

ISOMETER isopv with coupling device AGH-PV

PHOENIX CONTACT Features

Residual Current Devices FRCdM Type B, B+ and Bfq Digital

Transcription:

Leutron Lightningand Surge Protection for Power Net Systems (SPD) with EnerPro Combi-Devices Seite 0 von14

Novelties 2003 Combi Surge Protectors Leutron GmbH, 70771 Leinfelden-Echterdingen, Deutschland Leutron Lightning and Surge Protection for Power Net Systems (SPD) EnererPro Combi-Surge Protectors for TN and TT- Power Net Systems Secondary T2, pluggable Secondary T2 and Fine-Protection T3 Type: Page EP C TNC 275 2 EP C TNC 275 /FM 2 EP C TNS 275 2 EP C TNS 275 /FM 2 EP C TT 275 4 EP C TT 275 /FM 4 EP C TT1+1 275 4 EP C TT1+1 275 /FM 4 EP C TN 275 2 EP C TN 275 /FM 2 EP C S TNC 275 6 EP C S TNC 275 /FM 6 EP C S TNS 275 6 EP C S TNS 275 /FM 6 EP C S TT 275 8 EP C S TT 275 /FM 8 EP C S TT1+1 275 8 EP C S TT1+1 275 /FM 8 EP C S TN 275. 6 EP C S TN 275 /FM. 6 EP D TNC 275 10 EP D TNC 275 /FM 10 EP D TNS 275 10 EP D TNS 275 /FM 10 EP D TT 275 12 EP D TT 275 /FM 12 EP D TT1+1 275 12 EP D TT1+1 275 /FM 12 EP D TN 275 10 EP D TN 275 /FM 10 Seite 1 von14

Surge Protection EnerPro C TN EP C TN 275 (/FM) EP C TNC 275 (/FM) EP C TNS 275 (/FM) Combined multi-pole Surge Protective Device (SPD) protection category T2 (C) meeting the requirements of class II used as Surge Protector in multi-pole TN - Power Net Systems EP C TN 275 EP C TNC 275 EP C TNS 275 Category T2 Surge Protective Device (SPD) based on hermetically encapsulated gas filled Spark-Gaps Leakage-current-free to protect foundation grounding lines Can be co-ordinated with upstream installed T1 lightning current SPD Optical front monitoring by LED Function control with potential-free (NC) remote signal contact (optional) Product description: Leutron leakage current free SPD s of series EP C with surge voltage valve are single block SPD s, for different TN - Power Net Systems, usually installed in sub distribution panels. EP C TN 275(/FM) is a two-pole surge protector for TN - Power Net Systems. EP C TNC 275(/FM) is a three-pole surge protector for TNC - Power Net Systems. EP C TNS 275(/FM) is a four-pole surge protector for TNS - Power Net Systems. These SPD s are used as surge protectors for electronic equipments and systems. They are fitted with a thermal protection NC contact, which respond if the varistor exceed a certain level of temperature due to thermal overload. These thermal protection contact works in such a way, that they only cut off the SPD from the power supply whilst the electrical equipment will not suffer any functioning failure; in that case the green signal LED will go out. Before this happens, the remote contact (optional) inside the housing will open and signalise that the SPD has to be replaced. The wire connection to the built in remote contact (/FM) is made by a pluggable screw terminal block. The protective circuit is installed in an easy-to-handle compact housing with snap-on clips for 35 mm DIN rail mounting with multifunctional screw terminals for wire and bus-bar connections. Seite 2 von14

Technical Data: Type Art. Nr.: Remarks EP C TN 275 EP C TN /FM EP C TNC 275 EP C TNC 275 /FM EP C TNS 275 EP C TNS 275 /FM 381 247 381 248 381 176 381 177 381 178 381 179 resp. one phase and neutral (L1 / N PE) for three phases (L1 / L2 / L3 PEN) for three phases and neutral (L1 / L2 / L3 / N PE) Protection category acc. to E DIN VDE 0675-6 11/98-A1 and acc. to EN 61643-11 resp. IEC 61643-1 T2 (C) class II Nominal voltage 50/60 Hz U N [V] 230 / 400 Rated voltage (max. continuous operating voltage) 50/60 Hz U C [V] 275 Max. permissible line- or backup fuse I [A] 100 A gl/gg Voltage protection level at 5kA (8/20 µs) U P [kv] 1.0 Voltage protection level at i sn (8/20 µs) U P [kv] 1.4 Response time t A [ns] < 25 Nominal discharge current (8/20 µs) i sn (I N) [ka] 10x 15 Max. discharge current (8/20 µs) I max [ka 1x 40 Service life test current (10/700 µs) i L [A] 500x 100 100x 500 1x 1000 Operating temperature range t [ C] -40 +85 Max. cross-sectional area [mm²] 50 stranded / 35 flexible Recommended cross-sectional area [mm²] 25 Recommended connection torque [Nm] 4,5 Max. cross-sectional area for remote signal contact terminal [mm²] 1,5 Max. switching capacity of remote signal contact (FM) [V/A] AC 250V 0.5A Material of housing / colour Polycarbonate (halogen free) UL94-V0 / yellow Ambient protection category (IEC/EN 60529) IP 20 Mounting on DIN rail 35mm (DIN / EN 50022) Dimension in mm / Diagram Dimension acc. DIN 43880 EP C (2 modules) EP C TNC (3 modules) EP C TNS (4 modules) 04.11.2003 2003 by Leutron GmbH Subject to technical modifications and delivery possibilities Leutron GmbH Overvoltage Protection Humboldtstraße 30 D-70771 Leinfelden-Echterdingen Phone +49 711 / 9 47 71-0 Fax +49 711 / 9 47 71-70 Email: info@leutron.de Web: www.leutron.de Seite 3 von14

Surge Protection EnerPro C TT EP C TT1+1 275 (/FM) EP C TT 275 (/FM) Combined multi-pole Surge Protective Device (SPD) meeting the requirements of protection category T2 (C), class II Surge Protection in multi-pole TN-Power Net Systems EP C TT1+1 275 EP C TT 275 Category T2 Surge Protective Device (SPD) Based on hermetically sealed gas filled spark-gap technology Leakage-current-free to protect foundation grounding lines Can be co-ordinated with upstream installed T1 lightning current SPD Optical front monitoring by LED Function control with potential-free remote signal NC-contact (optional) Product description: Leutron leakage current free SPD s of series EP C are single block SPD s for different TN- Power Net Systems, usually installed in sub-distribution panels. EP C TT1+1 275(/FM) is a two-pole SPD for single phase TT-Power Net Systems with one phase and neutral conductor, connected in the so called 1+1 circuit. EP C TT 275(/FM) is a four-pole SPD for TT-Power Net Systems, connected in the so called 3+1 circuit. These SPD s are used as surge protectors for electronic equipments and systems. They are fitted with a thermal protection NC-contact, which respond if the varistor exceed a certain level of temperature due to overload. These thermal protection contact works in such a way, that it only cut off the SPD from the power supply whilst the electrical equipment will not suffer any functioning failure; in that case the green signal LED will go out. Before this happens, the remote contact (optional) inside the housing will open and signalise that the SPD has to be replaced. The wire connection of the optional built in remote NCcontact (/FM) is made by a pluggable screw terminal block. The protective circuit is installed in an easy-to-handle compact housing with snap-on clips for 35 mm DIN rail mounting with multifunctional screw terminals for wire and bus-bar connections. Seite 4 von14

Technical Data: Type Art. Nr.: Remarks EP C TT1+1 275 EP C TT1+1 275 /FM EP C TT 275 EP C TT 275 /FM 381 182 381 183 381 180 381 181 for one phase and neutral (L1, N-PE) for three phases (L1, L2, L3), with N-PE sum current Spark Gap Protection category acc. to E DIN VDE 0675-6 11/98-A1 and acc. to EN 61643-11 resp. IEC 61643-1 T2 (C) class II Nominal power supply voltage 50/60 Hz U N [V] 230 / 400 Rated voltage (max. continuous operating voltage) 50/60 Hz U C [V] 275 Max. permissible line or backup fuse I [A] 100 A gl/gg L1, L2, L3 - N PE - N Voltage protection level at 5kA (8/20 µs) U P [kv] 1.0 1,3 Voltage protection level i sn (8/20 µs) U P [kv] 1.4 1,5 Response time t A [ns] < 25 Nominal discharge current (8/20 µs) i sn [ka] 15 20 Max. discharge current Service life test current (10/700 µs) I max i L [ka [A] 40 (8/20 µs) 500x 100 100x 500 1x 1000 Operation temperature range T [ C] -40 +80 I imp: 12 (10/350 µs) Q: 6 As W/R: 36 kj/ώ Max. cross-sectional area [mm²] 35 stranded / 25 flexible Recommended cross sectional area [mm²] 25 Recommended connection torque [Nm] 4,5 Max. cross-sectional area for remote signal contact terminal [mm²] max. 1,5 Max. switching capacity of remote signal contact (FM) [V/A] AC 250V / 0.5A Material of housing / colour Polycarbonate (halogen free) UL94-V0 / yellow Ambient protection category (IEC/EN 60529) IP 20 Mounting on 35mm DIN rail (DIN/EN 50022) Dimension in mm / Diagram Dimension acc. DIN 43880 EP C TT 1+1 modules EP C TT 3+1 modules 04.11.2003 2003 by Leutron GmbH Subject to technical modifications and delivery possibilities Leutron GmbH Overvoltage Protection Humboldtstraße 30 D-70771 Leinfelden-Echterdingen Phone +49 711 / 9 47 71-0 Fax +49 711 / 9 47 71-70 Email: info@leutron.de Web: www.leutron.de Seite 5 von14

Lightning and Surge Protection EnerPro C S pluggable EP C S TN 275 (/FM) EP C S TNC 275 (/FM) EP C S TNS 275 (/FM) Pluggable combined multi-pole Surge Protective Device meeting the requirements of protection category T2 (C), class II Surge Protection in multi-pole TN-Power Net Systems EP C S TN 275 EP C S TNC 275 EP C S TNS 275 Category T2 Surge Protective Device (SPD) Multi-pole complete device with socket and plugged-in protection modules Can be co-ordinated with an upstream installed T1 lightning current SPD High discharge capacity thanks to high-performance varistors (MOV) Failure indicator displayed by change of colour Potential-free SPDT remote contact (optional) for function control Product description: Leutron surge protectors series EP C S are single block SPD s with pluggable modules, usually installed in the sub-distribution panel. EP C S TN 275(/FM) is a two-pole surge protector for TN - Power Net System EP C S TNC 275(/FM) is a three-pole surge protector for TNC - Power Net System EP C S TNS 275(/FM) is a four-pole surge protector for the TNS - Power Net System These devices serve as surge protectors at the supply end of electrical equipment and systems. They are fitted with a thermal protective change over contact, which opens if the varistor exceed a certain level of temperature due to overload by too high leakage current. In that case, the failure indicator changes from green to red and the optional remote signal change-over contact switches over. The protective circuit is installed in an easy-to-handle compact socket for 35mm DIN rail mounting (EN50022) with multifunctional screw terminals for wire and bus-bar connection. There is an optional potential-free remote signal contact (/FM) inside the housing. The wire connection is made by a pluggable screw terminal block. Seite 6 von14

Technical Data: Type Art. Nr.: Remarks EP C S TN 275 EP C S TN 275 /FM EP C S TNC 275 EP C S TNC 275 /FM EP C S TNS 275 EP C S TNS 275 /FM 381 240 381 241 381 030 381 035 381 050 381 055 for one phase and neutral (L1 / N PE) for three phases (L1 / L2 / L3 PE) for three phases and neutral (L1 / L2 / L3 / N PE) EP C S 275 381 242 Pluggable line protection module for replacement, without socket Protection category acc. to E DIN VDE 0675-6 11/98-A1 and EN 61643-11 resp. IEC 61643-1 T2 (C) class II Nominal power supply voltage 50/60 Hz U N [V] 230 / 400 Rated voltage (max. continuous operating voltage) 50/60 Hz U C [V] 275 Max. permissible line resp. backup fuse I [A] 100 A gl/gg Voltage protection level at 5kA (8/20 µs) U P [kv] < 1.0 Voltage protection level at i sn (8/20 µs) U P [kv] < 1.4 Response time t A [ns] < 25 Nominal discharge current (8/20 µs) i sn [ka] 20 Max. discharge current (8/20 µs) I max [ka 40 Short-circuit withstand capability at max. perm. pre-fuse, 50Hz [ka] 25 Operating temperature range t [ C] -40 +80 Max. cross-sectional area [mm²] 50 stranded / 35 flexible Recommended cross-sectional area [mm²] 25 Recommended connection torque [Nm] 4,5 Max. cross-sectional area for remote signal contact [mm²] 1,5 Max. switching capacity of remote signal contact (FM) change over (SPDT) contact [V/A] AC 250 V 0,5 A / DC 250V 0,1A Ambient protection category (IEC/EN 60529) IP 20 Material of housing / colour Polyamide PA 6 30SV, UL94 V0 / yellow Mounting on 35mm DIN rail (DIN / EN 50022) Dimensions in mm / Diagram Dimension acc. DIN 43880 EP C S TN (2 modules) EP C S TNC (3 modules) EP C S TNS (4 modules) 04.11.2003 2003 by Leutron GmbH Subject to technical modifications and delivery possibilities Leutron GmbH Overvoltage Protection Humboldtstraße 30 D-70771 Leinfelden-Echterdingen Phone +49 711 / 9 47 71-0 Fax +49 711 / 9 47 71-70 Email: info@leutron.de Web: www.leutron.de Seite 7 von14

Surge Protection EnerPro C S pluggable EP C S TT 275 (/FM) EP C S TT1+1 275 (/FM) Pluggable combined multi-pole Surge Protective Device meeting the requirements of protection category T2 (C), class II surge protection in multi-pole TT- Power Net Systems EP C S TT 275 EP C S TT1+1 275 Category T2 Surge Protective Device (SPD) Multi-pole complete device with socket and plugged-in protection modules Can be co-ordinated with an upstream installed T1 lightning current SPD High discharge capacity thanks to high-performance varistors (MOV) Failure indicator display by change of colour Potential-free SPDT remote contact (optional) for function control Product description: Leutron surge protectors series EP C S are single block SPD s with pluggable modules usually installed in the sub-distribution panel. EP C S TT 275(/FM) is a four-pole surge protector for TT-Power Net Systems, connected in the so called 3+1 circuit. EP C S TT1+1 275(/FM) is a two-pole surge protector for TT-Power Net Systems, connected in the so called 1+1 circuit. These devices serve as surge protectors at the supply end of electrical equipment and systems. They are fitted with a thermal protective NC-contact which opens if the varistor exceed a certain level of temperature due to overload by too high leakage current. In that case, the failure indicator changes from green or yellow to red and the optional remote signal change-over contact switches over. There is an optional potential-free remote signal contact (/FM) inside the housing. The wire connection is made by a pluggable screw terminal block. The protective circuit is installed in an easy-to-handle compact socket for 35mm DIN rail mounting (EN 50022) with multifunctional screw terminals for wire and bus-bar connection. Seite 8 von14

Technical Data: Type Art. Nr.: Remarks EP C S TT 275 EP C S TT 275/FM EP C S TT1+1 275 EP C S TT1+1 275/FM EP C S 275 SP C S 255 381 040 381 045 381 024 381 025 381 242 381 244 for three phases and neutral (3+1) for one phase and neutral (1+1) Pluggable protection L N module for replacement, without socket Pluggable protection PE - N module for replacement, without socket Protection category acc. to E DIN VDE 0675-6 11/98-A1 and EN 61643-11 resp. IEC 61643-1 L - N T2 (C) class II Nominal power supply voltage 50/60 Hz U N [V] 230 / 400 Rated voltage (max. continuous operating voltage) 50/60 Hz U C [V] 275 255 Max. permissible line resp. backup fuse I [A] 100 A gl/gg Voltage protection level at 5kA (8/20 µs) U P [kv] 1.0 Voltage protection level at i sn (8/20 µs) U P [kv] 1.4 1,5 Response time t A [ns] < 25 < 100 PE N Nominal discharge current i sn [ka] 20 (8/20 µs) 12 (10/350 µs) Max. discharge current (8/20 µs) I max [ka 40 40 Short-circuit withstand capability at max. permissible pre-fuse, 50Hz [ka] 25kA Operating temperature range t [ C] -40 +80 Max. wire cross-sectional area [mm²] 50 stranded / 35 flexible Recommended wire cross-sectional area [mm²] 25 Recommended connection torque [Nm] 4,5 Max. cross-sectional area for remote signal contact [mm²] 1,5 Max. switching capacity of remote signal contact (change over (SPDT) contact [V/A] AC 250 V 0,5 A / DC 250V 0,1A Ambient protection category (IEC/EN 60529) IP 20 Material of housing / colour Polyamide PA 6 30SV, UL94 V0 / yellow Mounting on DIN rail 35mm (DIN / EN 50022) Dimensions in mm / Diagram Dimension acc. DIN 43880 EP C S TT (3+1 modules) EP C S TT (1+1 modules) 04.11.2003 2003 by Leutron GmbH Subject to technical modifications and delivery possibilities Leutron GmbH Overvoltage Protection Humboldtstraße 30 D-70771 Leinfelden-Echterdingen Phone +49 711 / 9 47 71-0 Fax +49 711 / 9 47 71-70 Email: info@leutron.de Web: www.leutron.de Seite 9 von14

Surge Protection EnerPro D TN EP D TN 275 (/FM) EP D TNC 275 (/FM) EP D TNS 275 (/FM) Combined multi-pole Surge Protective Device (SPD) meeting the requirements of protection category T3 (D), class III To be used as Surge Protector in multi-pole TN-Power Net Systems EP D TN 275 EP D TNC 275 EP D TNS 275 Category T3 Surge Protective Device (SPD) Longitudinal and transversal protection for connected equipment up to 16 A No leakage current to PE Can be co-ordinated with an up-stream installed T2 surge protector Optical front monitoring by LED Potential-free remote signal NC-contact (optional) Product description: Leutron serie EP D is a surge protector for equipment, to be installed as close as possible to the equipment. EP D TN 275(/FM) is a two-pole SPD in a single block for a two-pole TN-Power Net Systems. EP D TNC 275(/FM) is a three-pole SPD in a single block for a three-pole TNC-Power Net Systems. EP D TNS 275(/FM) is a four-pole SPD in a single block for a four-pole TNS-Power Net Systems. These devices serve as a category T3 surge protector at the supply end of electrical equipments and systems. The green LEDs shows if the operating voltage is achieved and the protective circuit is in full working condition. They are with a thermal protection NC-contact, which opens if the varistor exceed a certain level of temperature due to overload. These thermal protection is installed in such a way that they only cut off the SPD from the power supply whilst the electrical equipment will not suffer any functioning failure; in that case the green signal LED will go out. Before this happens, the optional remote signal contact will open. The protective circuit is installed in an easy-to-handle compact socket for 35mm DIN rail mounting with screw terminals for wire connection. Seite 10 von14

Technical Data: Type Art. Nr.: Remarks EP D TN 275 EP D TN 275/FM EP D TNC 275 EP D TNC 275 /FM EP D TNS 275 EP D TNS 275 /FM 381 254 381 255 380 524 380 525 380 530 380 531 resp. for one phase and neutral (L1 / N PE) resp. for one phase and neutral for three phases (L1 / L2 / L3 PE) for three phases for three phases and neutral(l1 / L2 / L3 / N PE) for three phases and neutral Protection category acc. to E DIN VDE 0675-6 11/98-A1 and acc. To EN 61643-11 resp. IEC 61643-1 Nominal voltage 50/60 Hz U N [V] 230 / 400 Rated voltage (max. continuous operating voltage) (50/60 Hz) U C [V] 275 / 480 Max. permissible line fuse I n [A] 16 A gl/gg Voltage protection level at 1 kv/µs U P [kv] 1,0 Voltage protection level at i sn U P [kv] 1,0 Response time t A [ns] < 25 Nom. discharge current (8/20 µs) i sn [ka] 10x 5 Max. discharge current (8/20 µs) I max [ka 1x 8 Service life test current (10/700 µs) i L [A] T3 500x 100 100x 500 Operating temperature range t [ C] -40 +80 Max. cross-sectional area [mm²] 2x 2,5 rigid / 2x 1,5 stranded with sleeve Max. cross-sectional area for remote signal contact [mm²] 2x 2,5 rigid / 2x 1,5 stranded with sleeve Max. switching capacity of remote signal NC-contact [V/A] 250V / 0.5A Material of Housing / colour Polycarbonate (halogen free) UL94-V0 / yellow Environment protection category IP 20 (IEC 60529) Mounting on DIN rail 35mm (DIN / EN 50022) Dimensions in mm / Diagram Dimension acc. DIN 43880 1 module 2 modules 2 modules EP D TN 275 EP D TNC 275 EP D TNS 275 28.10.2003 2003 by Leutron GmbH Subject to technical modifications and delivery possibilities Leutron GmbH Overvoltage Protection Humboldtstraße 30 D-70771 Leinfelden-Echterdingen Phone +49 711 / 9 47 71-0 Fax +49 711 / 9 47 71-70 Email: info@leutron.de Web: www.leutron.de Seite 11 von14

Surge Protection EnerPro D TT EP D TT1+1 275 (/FM) EP D TT 275 (/FM) Combined multi-pole Surge Protective Device (SPD) meeting the requirements of protection category T3 (D), class III To be used as Surge Protector in multi-pole TT-Power Net Systems EP D TT1+1 275 EP D TT 275 Category T3 Surge Protective Device (SPD) Longitudinal and transversal protection for connected equipment up to 16 A No leakage current to PE Can be co-ordinated with an up-stream installed T2 surge protector Optical front monitoring by LED Potential-free remote signal NC-contact (optional) Product description: Leutron serie EP D is a surge protector for equipment, to be installed as close as possible to the equipment. EP D TT1+1 275(/FM) is a two-pole SPD in a single block for one-phase TT-Power Net Systems with neutral conductor, connected in the so called 1+1-circuit. EP D TT 275(/FM) is a four-pole SPD in a single block for TT-Power Net Systems, connected in the so called 3+1-circuit. These devices serve as a category T3 surge protector at the supply end of electrical equipments and systems. The green LEDs shows if the operating voltage is achieved and the protective circuit is in full working condition. They are with a thermal protection NC-contact, which opens if the varistor exceed a certain level of temperature due to overload. These thermal protection is installed in such a way that they only cut off the SPD from the power supply whilst the electrical equipment will not suffer any functioning failure; in that case the green signal LED will go out. Before this happens, the optional remote signal contact will open. The protective circuit is installed in an easy-to-handle compact socket for 35mm DIN rail mounting with screw terminals for wire connection. Seite 12 von14

Technical Data: Type Art. Nr.: Remarks EP D TT1+1 275 EP D TT1+1 /FM EP D TT 275 EP D TT 275 /FM 380 538 380 539 380 535 380 536 for one phase and neutral (L1 PE / N PE) for one phase and neutral for three phases and neutral (L1 / L2 / L3 N / PE N) for three phases and neutral Protection category acc. to E DIN VDE 0675-6 11/98-A1 and acc. to EN 61643-11 resp. IEC 61643-1 Nominal voltage (50/60 Hz) U N [V] 230 / 400 Rated voltage (max. continuous operating voltage) (50/60 Hz) U C [V] 275 / 480 Max. permissible line fuse I n [A] 16 A gulag Voltage protection level at 1 kv/µs U P [kv] < 1,0 Voltage protection level at i sn U P [kv] < 1,0 Response time t A [ns] < 25 T3 L1, L2, L3 N PE N Nom. discharge current i sn [ka] 5 (8/20 µs) 20 (8/20 µs) Max. discharge current I max [ka 8 (8/20 µs) Service life test current (10/700 µs) i L [A] 500x 100 100x 500 Operating temperature range t [ C] -40 +80 I peak: 12 ka (10/350 µs) Q: 6 As W/R: 36 kj/ώ Max. cross-sectional area [mm²] 2x 2,5 rigid / 2x 1,5 stranded with sleeve Max. cross-sectional area for remote signal contact [mm²] 2x 2,5 rigid / 2x 1,5 stranded with sleeve Max. switching capacity of remote signal NC-contact [V/A] 250V / 0.5A Material of housing / colour Polycarbonate (halogen free) UL94-V0 / yellow Environment protection category IP 20 (acc. IEC/EN 60529) Mounting on DIN rail 35mm (EN 50022) Dimensions in mm / Diagram Dimension acc. DIN 43880 1 module 2 modules EP D TT1+1 275 EP D TT 275 28.10.2003 2003 by Leutron GmbH Subject to technical modifications and delivery possibilities Leutron GmbH Overvoltage Protection Humboldtstraße 30 D-70771 Leinfelden-Echterdingen Phone +49 711 / 9 47 71-0 Fax +49 711 / 9 47 71-70 Email: info@leutron.de Web: www.leutron.de Seite 13 von14