Digital input modules

Similar documents
Super universal modules

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

TXM1.8RB. TX-I/O Blinds module

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

Power supply module, bus connection module

Resistance measuring module

9283P01. Extension module. Integration of existing PT-I/O modules in Desigo Used with PXC50...D, PXC100...D or PXC200...D

BACnet/IP Web Interface

Web interface BACnet/IP

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use

Island bus expansion module

Rotary version, three-position control

Room unit with PPS2 interface

BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Room unit with PPS2 interface

Interface converter for VAV compact controllers

Rotary actuators for ball valves

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

USB-KNX Interface OCI702. USB-KNX interface with cables and service bag

Extension module Integration of existing PTM I/O modules in Desigo Used with PXC50...D, PXC100...D or PXC200...D

Air damper actuators

Extension module for lighting control

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

OCI Service tool. As of ACS790 V9.00. Service case with software and service interface

Air Damper Actuators Modbus RTU

Air Damper Actuators Modbus RTU

Fast running actuators for air dampers

s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix

Touch Panels 10.1" and 15.6"

SAX.. ACVATIX Electromotive actuators for valves. with a 20 mm stroke

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

Airflow Pressure Sensor

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Handheld Tool for VAV compact and modular controllers

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

Room automation station

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

RMZ790. Operator Unit. Building Technologies. Synco 700

VAV modular controller

VAV compact controller

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

Room Temperature Controller

Room automation stations

Communication module to connect M-bus devices to POL6xx.xxx controllers.

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

Touch Panels 10.1" and 15.6"

Electromotoric actuators

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

AEW Pulse Adapter. Building Technologies

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Electromotive actuators for combi valves

Network node WTT56.. A6V _en--_c Building Technologies

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Room unit with PPS2 interface

Installation Instructions

Room unit with PPS2 interface

Rotary actuator for ball valves KNX / PL-Link

Communication over Modbus protocol Connection with multiple controllers Application upgrade by using an SD 1) card or a USB stick

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Product and functional description

QVE3000.0xx QVE3100.0xx. Flow sensor. for liquids in DN10 25 pipes

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

LON Module for Variable Speed Drive

Freely configurable flush-mounted room operator unit for KNX PL-Link

Transponder card holder

PHOENIX CONTACT Features

Compact room automation stations, BACnet/IP, AC 230 V

Electromotoric actuators

VAV Compact Controller Modbus RTU

Fork light barriers SOOF

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Product and functional description

Non-communicating room controllers

Mobile Data Collector

Compact actuating room automation stations, BACnet/IP, AC24 V (Actuating DXR)

RXL21.1 RXL22.1. Room controllers RXL. Communicating controllers for fan-coil applications FC-10, FC-11, FC12

SEH62.1. Digital Time Switch

Use. Functions. OpenAir TM. Linear version, modulating, AC 24 V

RMZ792. Bus Operator Unit. Building Technologies HVAC Products. Synco 700

Accessories and options

Immersion Temperature Sensors

Semi flush-mounted room temperature controllers with LCD

AEW36.2. Pulse Adapter. Building Technologies. Siemeca AMR

Status display unit with P-bus connection

Product and functional description

Fume Hood Cable Sash Sensor

ERF910. RF Repeater. Synco living

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

Product and functional description

Transponder card reader

Automation station, compact series

Installation Instructions

Transcription:

8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a green LED 8 or 16 digital inputs; individually configurable for status signals, status pulses (with a memory function) or counter pulses (up to 10 Hz) Compact DIN format, small footprint Separate terminal base and plug-in I/O module for convenient handling Self-establishing bus connection for maximum ease of installation Terminal isolation function for fast commissioning I/O module replaceable in seconds, without rewiring and without affecting the full functioning of the remaining I/O modules All terminals are directly on the I/O modules, allowing direct connection of field devices without additional terminal strips. Simple strategy for operation and display I/O status LED for each I/O point; mode of operation (N/C or N/O) depends on I/O function LEDs for fast diagnostics Double-sided labels for identification of all I/O points CM2N8172en_06 2017-07-05 Building Technologies

Functions The modules support the following I/O functions: Function Signal type (TRA) Signal type Status indication BI NO D20 BI NC D20R Description Volt-free, interrogation (maintained contact), N/O contact Volt-free, interrogation (maintained contact), N/C contact Status pulses BI Pulse NO BI Pulse NC D20S Volt-free, interrogation (pulse) N/O / N/C contact Button input BI Push NO BI Push NC -- Button input single / dual, volt-free N/O / N/C contact Status multistate MI Switch -- Multistate input, 2...8-stage, volt-free, interrogation Counter pulses CI Mech (10/25Hz) C Volt-free, N/O contact, interrogation (pulse, max. 10 Hz) (TXM1.16D: I/O points1... 8 only) For a detailed description of these functions, please refer to document CM1105761, "TX-I/O Functions and operation". Compatibility Support of signal types and functions in different building automation and control systems: see TX-I/O Engineering and installation manual, CM110562 Type summary ASN Delivery Digital input module TXM1.8D Digital input module TXM1.16D The terminal base and the plug-in I/O module are interconnected and delivered in the same box. Accessories The available accessories include address keys, label sheets, and spare transparent label holders. Refer to data sheet CM2N8170. Technical and mechanical design For a description of the features common to all TX-I/O modules, please refer to the TX-I/O Engineering and installation manual, document CM110562. 2/8

Indicators and operator controls Connection terminals (No. 1 screwdriver for slotted or recessed-head * screws) with test pickup (for 1.8...2 mm pins) and terminal number Signal designation Address key and module status LED I/O point numbers (I/O points 9... 16: TXM1.16D only) I/O status LEDs (TXM1.8D: Configurable - green/yellow/red TXM1.16D: Green) * Combined slotted / recessed-head screws from mid-2012 I/O status LEDs The I/O status LEDs indicate the status of the inputs and outputs (peripheral devices) The LEDs on the TXM1.16D are green In the case of the TXM1.8D the LEDs are three-colored. If the I/O function supports it, the module can display Alarm = red and Service = yellow, besides Normal = green The LEDs are also used for diagnostic purposes Module status LED The module status LED illuminates the transparent address key The (green) LED shows the status of the module as a whole (as opposed to the status of the I/O points) It is also used for diagnostics Address key The module operates only with the address key inserted The module address is mechanically encoded in the address key When replacing the plug-in I/O module, the address key must be swiveled outward. It remains plugged into in the terminal base. 3/8

Module labeling The plug-in I/O module has a removable transparent cover (the label holder) for insertion of a label. 2 1 8172z11 Disposal The devices are considered electronics devices for disposal in terms of European Directive 2012/19/EU and may not be disposed of as domestic garbage. Dispose of the devices through channels provided for this purpose. Comply with all local and currently applicable laws and regulations. Engineering, mounting, installation Please refer to the following documents Document TX-I/O Functions and operation TX-I/O Engineering and installation manual Replacement of legacy modules Number CM110561 CM110562 CM110563 Mounting Permitted orientation The TX-I/O devices can be installed in any orientation: It is important to provide adequate ventilation so that the admissible ambient temperature (max. 50 C) is not exceeded. 4/8

Technical data Supply (bus connector on side) Operating voltage Max. power consumption TXM1.8D 1.1 W TXM1.16D 1.4 W (for the sizing of power supplies, see CM110562) DC 21.5... 26 V (SELV / PELV) or DC 24 V class 2 (US) Protection All terminals of the modules Against shortcut and incorrect wiring with AC / DC 24 V Bus connector on side No protection! Field devices Insulation resistance The of the connected field devices against mains voltage must comply with the requirements for safety extra-low voltage (SELV) or protection by extra-low voltage (PELV) as per HD 384. Measuring cables Cable material Solid or stranded copper wire Cable cross section See manual CM110562 Permitted cable length max. 300 m Digital inputs / counter inputs *) Digital inputs are not electrically separated from the system electronics. Mechanical contacts must be volt-free Electronic switches must comply with SELV / PELV standards. Contact sensing voltage Contact sensing current Contact resistance with contacts closed Insulation resistance with contacts open DC 21.5...25 V 1.6 ma (initial current 10 ma) Max. 200Ω Min. 50kΩ Min. closing / opening time [ms] including bouncing Max. bounce time [ms] Max. Counting frequency (symmetric) Maintained contact 80 40 Pulse contact 50 30 Counter *) 40 30 10 Hz Counter memory *) 0... 4.3 x 10 9 (32 bit counter) *) Counting function for TXM1.16D: I/O points 1... 8 only Connection terminals Mechanical design Solid conductors Stranded conductors without connector sleeves Stranded conductors with connector sleeves (DIN 46228/1) Screwdriver Rising cage terminals 1 x 0.5 mm 2 to 4mm 2 or 2 x 0,6 mm to 1.5 mm 2 1 x 0.5 mm 2 to 2.5 mm 2 or 2 x 0,6 mm to 1.5 mm 2 1 x 0.25 mm 2 to 2.5 mm 2 or 2 x 0,6 mm to 1.5 mm 2 No. 1 Screwdriver for slotted or recessed-head * screws with shaft diameter 4.5 mm * Combined slotted / recessedhead screws from mid-2012 0.6 Nm Max. tightening torque Test pickups (terminals) For pin diameter 1 x 1.8 2.0 mm Classification to EN 60730 Mode of operation of automatic electrical controls Type 1 5/8

Housing protection standard Ambient conditions Contamination level Mechanical design Protection standard to EN 65029 Front-plate components in DIN cut-out Terminal base Operation Climatic conditions Temperature Humidity Mechanical conditions Transport / storage Climatic conditions Temperature Humidity Mechanical conditions 2 Protection class III IP30 IP20 To IEC 60721-3-3 Class 3K5 5... 50 C 5 95 % rh Class 3M2 To IEC 60721-3-2 Class 2K3 25 70 C 5 95 % rh Class 2M2 Standards, directives and approvals Environmental compatibility Product standard EN 60730-1 Automatic electrical controls for household and similar use Electromagnetic compatibility (Applications) For use in residential, commercial, light-industrial and industrial environments EU conformity (CE) CM1T10870xx *) UL certification (US) UL 916, UL 864, http://ul.com/database CSA certification Class 4812 http://directories.csainternational.org/ RCM-conformity (EMC) CM1T10870en_C1 *) EAC conformity Eurasia conformity Product environmental declaration (contains data CM2E8172 *) on RoHS compliance, materials composition, packaging, environmental benefit, disposal) Color Terminal base and plug-in I/O module RAL 7035 (light gray) Dimensions Housing to DIN 43 880, see "Dimensions" Weight Without / with packaging TXM1.8D 164 / 185 g TXM1.16D 199 / 220 g *) The documents can be downloaded from http://siemens.com/bt/download. 6/8

Connection diagrams (examples) U U Digital input module (1) (2) (3) (4) (5) 1 2 3 4 5 6 7 8 9 10 K1 K2 K3 K4 S5 8172z13 K1 K2 K3 K4 S5 Status contact (N/O) Status contact (N/C) Pulse contact (N/O) Pulse contact (N/C) Electronic switch Terminal layout TXM1.8D, TXM1.16D TXM1.16D only I/O point (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (16) System neutral ( ) 1) 1 3 5 7 9 11 13 15 18 20 22 24 26 28 30 32 Input (+) 2 4 6 8 10 12 14 16 19 21 23 25 27 29 31 33 1) Terminals 1, 3, 5 etc. are system neutral terminals They are interconnected, not in the terminal base but in the plug-in I/O module. This means that when the I/O module is removed, there is no connection. The system neutral of a digital input can be connected to any system neutral terminal For wiring details refer to the TX-I/O Engineering and installation manual, CM110562. 7/8

Dimensions Dimensions in mm 90 67 45 22 44 70 77.5 7.1 98 108 64 3 8172M01 Published by: Siemens Switzerland Ltd. Building Technologies Division International Headquarters Gubelstrasse 22 6301 Zug Switzerland Tel. +41 41-724 24 24 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd 2007 Delivery and technical specifications subject to change 8/8