BACnet Protocol Implementation Conformance Statement (PICS)

Similar documents
BACnet Protocol Implementation Conformance Statement (PICS)

BACnet Protocol Implementation Conformance Statement (PICS)

ASHRAE s BACnet Protocol Implementation Conformance Statement (PICS)

ASHRAE s BACnet Protocol Implementation Conformance Statement (PICS)

BACnet IP for Quantum

Maverick I Commercial Packaged Rooftop Systems Unit Controller Protocol Implementation Conformance Statement (PICS) ANSI/ASHRAE , BACnet

NXAC-120 Area Controller

BACnet Protocol Implementation Conformance Statement

MicroTech II Multiple Air Handler Controller

Sales and Engineering Data Sheet ED

BACnet Protocol Implementation Conformance Statement

TB7300 Series Fan Coil Unit Communicating Thermostats BACnet Protocol Implementation Conformance Statement (PICS)

NS Series CO 2 Network Zone Sensors Protocol Implementation Conformance Statement

1. BACnet Protocol Implementation Conformance Statement

1. BACnet Protocol Implementation Conformance Statement

IQ4NC/.../ BACnet PICS

Zoning System TEC2647Z-2 and TEC2647Z-2+PIR Zone Controllers Protocol Implementation Conformance Statement

PXC Compact Series on BACnet/IP

WT-BAC-IP Gateway Protocol Implementation Conformance Statement

BACnet Protocol Implementation Conformance Statement

BACnet Protocol Implementation Conformance Statement Automated Logic G5RE

Delta Control Unit (DCU) 3.30 BACNET PROTOCOL IMPLEMENTATION CONFORMANCE STATEMENT

Product Implementation Conformance Statement bcx1-r

QC BAC-BOX PIC STATEMENT

ETC Reference Guide BACnet PICS for P-CCS

NS Series Temperature and Humidity Network Zone and Discharge Air Sensors Protocol Implementation Conformance Statement

CAS BACnet Stack Product Data Sheet

entelibus CPU Engine (eb-eng) Firmware

ESAC ebacgw SNMP. Date: Mar 08,2009. Product Model Number: Product Version: 1.0 BACnet Protocol Revision: 3. Product Description:

Delta ORCAview Date: August 5, 2009 Vendor Name: Delta Controls Inc. Product Name:

BACnet Protocol Implementation Conformance (PIC) Statement

Delta Controller Engine (DCE) Firmware

Protocol Implementation Conformance Statement (Normative) BACnet Protocol Implementation Conformance Statement

BACnet RIB June 24, 2016

BTL Listed March 2013

BACnetRIB June 24, 2016

BACnet RIB March,

BACnet RIB Jan

Siemens BACnet VAV Actuator

Date: Vendor Name: Product Name: Product Model Number: Applications Software Version: Firmware Revision: BACnet Protocol Revision:

PROTOCOL IMPLEMENTATION CONFORMANCE STATEMENT (NORMATIVE) (This annex is part of this Standard and is required for its use.)

BACnet Protocol Implementation Conformance Statement Automated Logic Corporation LGR25, LGR250, LGR1000

Distech Controls Application Specific Controllers PICS

FX Server BACNET AWS Protocol Implementation Conformance Statement

BACnet Protocol Implementation Conformance Statement

Wireless Pneumatic Thermostat BACnet Gateway PICS. Document No rev 01

BACnet RIB July 1, 2014

MatrixBBC. Protocol Implementation Conformance Statement (PICS) Product Description: BACnet Standardized Device Profile:

BACnet Terminal Box (VAV) Controller

BACnet Protocol Implementation Conformance Statement (PICS) MULTICAL 62/601/602/6L2/6M2/801

Belimo Gateway MP to BACnet MS/TP - UK24BAC

BACnet Protocol Implementation Conformance Statement

Heatronic Introduction. BAS Integration Manual. Table of Contents

Procon BAC-A/50. Installation Instructions MITSUBISHI ELECTRIC

S4 Open: BACnet N2 Router

Input/Output Module (IOM) Series Protocol Implementation Conformance Statement

HMS-1655 BACnet MS/TP Protocol Implementation Conformance Statement

NB-GPC Family Protocol Implementation Conformance Statement (PICS)

BACnet Protocol Implementation Conformance Statement

BACnet Protocol Implementation Conformance Statement OEMPrtl Pro

SyxthSense Room Controller (SRC1) Platform. BACnet Protocol Implementation Conformance Statement

Honeywell ComfortPoint TM Open Plant Controller Protocol Implementation Conformance Statement (PICS)

SITRANS F. Ultrasonic Flowmeters SITRANS F US Clamp-on Communications Module. Introduction 1. F US Clamp-on Communications Module Kit 2

Modular Series BACnet Protocol Implementation Conformance (PIC) Statement A6V Building Technologies

MULTICAL 403 MULTICAL 603

BACnet Protocol Implementation Conformance Statement

Proposed Addendum al to Standard , BACnet - A Data Communication Protocol for Building Automation and Control Networks

PXC Compact Unitary Equipment Controller BACnet Protocol Implementation Conformance Statement

Siemens BACnet Programmable TEC Unit Vent Controller

Carbon Monoxide Transmitter

homelynk/spacelynk BACnet Protocol Implementation Conformance Statement

BACnet Protocol Implementation Conformance Statement

NB-ASC Family Protocol Implementation Conformance Statement (PICS)

Table of Contents. NBC User's Manual

BACnet Protocol Implementation Conformance Statement

BACnet Protocol Implementation Conformance Statement

BACnet Protocol Implementation Conformance Statement

BACnet Protocol Implementation Conformance Statement Unitary Protocol Converter (UPC)

Honeywell ComfortPoint TM Open Plant Controller Protocol Implementation Conformance Statement (PICS)

NB-V3Tb Protocol Implementation Conformance Statement (PICS)

Building Operation. Vendor ID 10

Honeywell Novar XIO Remote I/O Protocol Implementation Conformance Statement (PICS)

BACnet Protocol Implementation Conformance Statement

BACnet MS/TP-module. Data sheet. for MULTICAL 403 and 603

BACnet RIB July,

BACnet Protocol Implementation Conformance Statement

BACnet Protocol Implementation Conformance Statement

Integration Specification Sheet

BACnet Protocol Implementation Conformance Statement (PICS) der Automationsstation miles-as29/b

TC Modular Series. Features. Description. Technical Specification Sheet Document No Rev. 1, July 31, 2008

Siemens BACnet Programmable TEC Unit Vent Controller for Smoke Control

NB-VAV Family Protocol Implementation Conformance Statement (PICS)

Product Implementation Conformance Statement bcx-4040

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller

MXB-50 BACnet Interface for Mitsubishi Air-Conditioning

Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller for Smoke Control

Siemens BACnet Programmable TEC Unit Conditioner Controller

Siemens BACnet Programmable TEC Constant Volume

BACnet Integration Manual ITG-VZ7xxx-BAC-E04.doc ( _R4 Issue Date: May 31 st, 2012)

Transcription:

BACnet Protocol Implementation Conformance Statement (PICS) Date: May 24, 2016 Vendor Name: Lutron Electronics Co., Inc. Product Name: Quantum BACnet Integration Applications Version: 2.0 Firmware Revision: 3.1 BACnet Protocol Revision: 4 Vendor ID: 176 369997a 1 05.24.16 Product Description BACnet IP is embedded in the Quantum processor. There are two types of BACnet devices available in Quantum subsystem devices and area devices: The subsystem devices are physical BACnet devices; typically, one per floor of the building. The area devices are virtual BACnet devices, typically one per area of the floor. It is typical to have multiple subsystem devices and area devices in a Quantum system. Areas devices are routed through the subsystem device which is also a BACnet router. BACnet Interoperability Building Blocks Supported (Annex K): K.1.2 BIBB Data Sharing ReadProperty-B (DS-RP-B) K.1.4 BIBB Data Sharing ReadPropertyMultiple-B (DS-RPM-B) K.1.8 BIBB Data Sharing WriteProperty-B (DS-WP-B) K.1.10 BIBB Data Sharing WritePropertyMultiple-B (DS-WPM-B) K.1.12 BIBB Data Sharing COV-B (DS-COV-B) K.5.2 BIBB Device Management DynamicDeviceBinding-B (DM-DDB-B) K.5.4 BIBB Device Management DynamicObjectBinding-B (DM-DOB-B) K.5.6 BIBB Device Management DeviceCommunicationControl-B (DM-DCC-B) BACnet is a registered trademark of ASHRAE. ASHRAE does not endorse, approve or test products for compliance with ASHRAE standards. Compliance of listed products to the requirements of ASHRAE Standard 135 is the responsibility of BACnet International (BI). BACnet Standardized Device Profile (Annex L): BACnet Application Specific Controller (B-ASC) Segmentation Capability: Segmented requests supported? No. Segmented responses supported? No. Window Size: n/a Window Size: n/a Non-Standard Application Services: Non-standard application services are not supported.

Standard Object Types Supported: Device 1. Dynamically creatable using BACnet CreateObject service? No. 2. Dynamically deletable using BACnet DeleteObject service? No. 3. List of optional properties supported: Active COV_Subscriptions, Description, Location, Profile_Name. 4. List of all properties that are writable where not otherwise required by this standard: None. 5. List of proprietary properties: None. 6. List of any property value range restrictions: None. Binary Value 1. Dynamically creatable using BACnet CreateObject service? No. 2. Dynamically deletable using BACnet DeleteObject service? No. 3. List of optional properties supported: Active_Text, Inactive_Text. 4. List of all properties that are writable where not otherwise required by this standard: None. 5. List of proprietary properties: None. 6. List of any property value range restrictions: See Table. Multi-State Value 1. Dynamically creatable using BACnet CreateObject service? No. 2. Dynamically deletable using BACnet DeleteObject service? No. 3. List of optional properties supported: State_Text. 4. List of all properties that are writable where not otherwise required by this standard: None. 5. List of proprietary properties: None. 6. List of any property value range restrictions: See Table. Data Link Layer Options: BACnet IP Device Address Binding: Is static device binding supported? No. 369997a 2 05.24.16 Networking Options: BACnet / IP Annex J non-bbmd functionality; the Quantum processor is able to register as a foreign device. The Quantum processor is able to initiate original broadcast NPDU. Character Sets Supported: Indicating support for multiple character sets does not imply that they can all be supported simultaneously. ANSI X3.4 BACnet Routing: Routes between the connected physical BACnet network and a virtual BACnet network.

369997a 3 05.24.16 {Subsystem Name} {Device Instance Number} Inactive Text (0) Active Text (1) DEVICE Same as device instance number X Notes: The System Name is the logical name of one of the Quantum system s subsystems that typically corresponds to a physical portion of the building, such as a floor. The Instance is the same as the unique Device ID assigned to each subsystem. Master Loadshed BV 2 X X X 0 1 Disabled Notes: This value determines whether all of the areas in the Quantum subsystem are being controlled via load shedding. When this value is set to, for all areas in the subsystem that have loadshed allowed, any dimmable lights in each area that are turned On will have their light level reduced by the percentage specified in the loadshed goal value. When Disabled, the lights will dim to their commanded level. Master HyperionTM BV 3 X X X 0 1 Disabled Notes: When the Master HyperionTM feature is set to, for all areas in the Quantum subsystem that have HyperionTM configured, the HyperionTM feature will control the Lutron Sivoia QS roller shades and set their level automatically depending on the position of the sun. When the Master HyperionTM feature is set to Disabled, in all areas of the subsystem, the shades will not be controlled automatically by the HyperionTM feature and will not respond to radio window sensors. Roof-Mount Cloudy Day Sensor: Subsystem Status BV 4 X X X 0 1 Dark Sunny Notes: A Lutron roof-mounted, wired Cloudy Day sensor or a BMS system sensor is used to override all HyperionTM controlled shades in the subsystem. Sunny indicates that the HyperionTM feature is in control of the shades; Dark indicates that the shades are overridden to open. This feature is independent of the radio window sensor feature. (continued on next page) BV = Binary-Value {SystemName} is a text string defined in the Lutron Quantum system configuration software {Instance} is a number defined in the Lutron Quantum system configuration software that is equal to the {Base} number + {System} number +1 {Base} is a 22-bit value set in the Lutron Quantum system configuration software (default 1760000) {System} is an 8-bit value set in the Lutron Quantum system configuration software (0 to 127) = Present-Value

369997a 4 05.24.16 {TimeclockName} BV 1000 to 1999 Inactive Text (0) Active Text (1) X X X 0 1 Disabled Notes: For each timeclock in the QuantumR system, there will be one instance number in the range from 1000 to 1999, that can either Enable or Disable that timeclock in the subsystem, or query its current enable state. Please note that for each such instance, there will be a corresponding instance at the same offset but within the range from 2000 to 2999, a {TimeclockName} Enable Command object, similar but with more functionality. Please note that if there are multiple subsystems, the instance number representing an individual timeclock appears in each subsystem s BACnet system device. To enable or disable the timeclock for all subsystems, write to the same instance number in each subsystem s BACnet system device. Write with 0 to Disable Permanently. The timeclock will no longer affect objects in the subsystem. Write with 1 to Enable Without Catch Up. The timeclock will affect objects in the subsystem as programmed, but only starting with future events. Read {TimeclockName} will return 0 (Disabled) if the last {TimeclockName} Enable Command was any of the following: Disable Permanently Disable Until End of Day Without Catch Up Disable Until End of Day With Catch Up Read {TimeclockName} will return 1 () if the last {TimeclockName} Enable Command was any of Enable Without Catch Up Enable With Catch Up Enable and Run Previous Event Only BV = Binary-Value, MSV = Multi-State-Value {TimeclockName} is a text string defined in the Lutron Quantum system configuration software {VariableName} is a text string defined in the Lutron Quantum system configuration software {VariableStateCount} is the number of states defined for this variable in the Lutron Quantum system configuration software {StateName} is a text string defined in the Lutron Quantum system configuration software = Present-Value

369997a 5 05.24.16 {TimeclockName} Enable Command MSV 2000 to 2999 Inactive Text (0) Active Text (1) X X X 1 6 1 = Disable Permanently 2 = Disable Until End of Day Without Catch Up 3 = Disable Until End of Day With Catch Up 4 = Enable Without Catch Up 5 = Enable With Catch Up 6 = Enable and Run Previous Event Only Notes: For each timeclock in the Quantum system, there will be one instance number in the range from 2000 to 2999, that can either Enable or Disable that timeclock in the subsystem, or query its current enable state. Please note that for each such instance, there will be a corresponding instance at the same offset but within the range from 1000 to 1999, a {TimeclockName} object, similar but with less functionality. Please note that if there are multiple subsystems, the instance number representing an individual timeclock appears in each subsystem s BACnet system device. To enable or disable the timeclock for all subsystems, write to the same instance number in each subsystem s BACnet system device. WRITING: Write with 1 to Disable Permanently. The timeclock will no longer affect objects in the subsystem. Write with 2 to Disable Until End of Day Without Catch Up. The timeclock will not affect objects in the subsystem until midnight, at which time it will affect objects in the subsystem as programmed, but only starting with future events. Write with 3 to Disable Until End of Day With Catch Up. The timeclock will not affect objects in the subsystem until midnight, at which time it will catch up, or set objects in the subsystem to the net state that would have occurred had the timeclock been enabled the whole time. Thereafter, it will affect objects in the subsystem as programmed. Write with 4 to Enable Without Catch Up. The timeclock will affect objects in the subsystem as programmed, but only starting with future events. Write with 5 to Enable With Catch Up. The timeclock will catch up, or set objects in the subsystem to the net state that would have obtained had the timeclock never been disabled (accounting for missed events for up to the last seven days). Thereafter, it will affect objects in the subsystem as programmed. Write with 6 to Enable and Run Previous Event Only. The timeclock will run only the single last scheduled event. Thereafter, it will affect objects in the subsystem as programmed. READING: If timeclock state was last changed by writing to {TimeclockName} Enable Command any of: Disable Permanently Disable Until End of Day Without Catch Up Disable Until End of Day With Catch Up Read thereof will return the same (1, 2, or 3). If timeclock state was last changed by writing to {TimeclockName} Enable Command was any of: Enable Without Catch Up Enable With Catch Up Enable and Run Previous Event Only Read thereof will return 4 (Enable Without Catch Up). If timeclock state was last changed by writing 0 to the {TimeclockName} instance, then read of {TimeclockName} Enable Command will return 1 (Disable Permanently). If timeclock state was last changed by writing 1 to the {TimeclockName} instance, then read of {TimeclockName} Enable Command will return 4 (Enable Without Catch Up). {VariableName} Current Variable State MSV 4000 to 4999 X X X 1 {Variable State Count} {StateName} Notes: The current value of a State Variable. The State Variable can be used during the evaluation of conditional logic on button programming as configured in the Quantum system configuration software. The number of states, as well as the state names, must be configured inside the Quantum system configuration software. BV = Binary-Value, MSV = Multi-State-Value {TimeclockName} is a text string defined in the Lutron Quantum system configuration software {VariableName} is a text string defined in the Lutron Quantum system configuration software {VariableStateCount} is the number of states defined for this variable in the Lutron Quantum system configuration software {StateName} is a text string defined in the Lutron Quantum system configuration software = Present-Value

369997a 6 05.24.16 {Timeclock Name} / {Timeclock Event} Inactive Text (0) Active Text (1) BV 5000 to 5999 X X X 0 1 Disabled {Timeclock Name} / {Timeclock Event} Hour Notes: For each timeclock event in the QuantumR subsystem, there will be one instance in the range of 5000 to 5999 that can be used to enable or disable the individual events in the timeclock. Note that each timeclock may contain more than one event. Note that each timeclock may contain more than one event. Also note that the timeclock Event, Hour, and Minute Instances are all correlated to each other by the last 3 digits of the instance number. AV 6000 to 6999 X X X Hours 0 23 N/A N/A Notes: For each timeclock event in the QuantumR subsystem, there will be one instance in the range of 6000 to 6999 that can be used to set the hour at which each timeclock event will occur. The hour is set in the 24 hour format (0 = 12 midnight). Note that each timeclock may contain more than one event Note that each timeclock may contain more than one event. Also note that the timeclock Event, Hour, and Minute Instances are all correlated to each other by the last 3 digits of the instance number. {Timeclock Name} / {Timeclock Event} Minute AV 7000 to 7999 X X X Minutes 0 59 N/A N/A Notes: For each timeclock event in the QuantumR subsystem, there will be one instance in the range of 7000 to 7999 that can be used to set the minute at which each timeclock event will occur. The minute of the event can be set from 0 to 59. Note that each timeclock may contain more than one event. Also note that the timeclock Event, Hour, and Minute Instances are all correlated to each other by the last 3 digits of the instance number. BV = Binary-Value, MSV = Multi-State-Value {TimeclockName} is a text string defined in the Lutron Quantum system configuration software {VariableName} is a text string defined in the Lutron Quantum system configuration software {VariableStateCount} is the number of states defined for this variable in the Lutron Quantum system configuration software {StateName} is a text string defined in the Lutron Quantum system configuration software = Present-Value