PACSystems* RX3i Central Processing Unit IC695CPE305 Quick Start Guide

Similar documents
PACSystems* RX3i Central Processing Unit IC695CPE302 Quick Start Guide GFK-3038 February 2018

GE Intelligent Platforms

GE Intelligent Platforms Programmable Control Products PACSystems* RX3i DNP3 Slave Module IC695EDS001. Quick Start Guide GFK-2912 October 2014

Instructions to printer DO NOT PRINT THIS PAGE

PACSystems* RX3i Genius* Communications Gateway, IC695GCG001. Quick Start Guide, GFK-2891C August 2016

PACSystems* RX3i 1GHz 64MB CPU w/ethernet IC695CPE330 Quick Start Guide GFK-2941J November 2018

Shown with terminal block Supports diagnostic point fault contacts in the logic program

PACSystems* RSTi-EP EPSCPE100 Enhanced performance standalone controller for RSTi-EP Platform CPU Quick Start Guide

PACSystems* RSTi-EP EPSCPE100 Enhanced performance standalone controller for RSTi-EP Platform CPU Quick Start Guide

PACSystems* RX3i CANopen Master Module, IC695CNM001 Quick Start Guide, GFK-2837 March 2013

PACSystems* RSTi-EP EPSCPE115 Standalone CPU Quick Start Guide GFK-3039 April 2018

PACSystems* RX3i IC694ALG233

PACSystems* RSTi-EP EPSCPE100 Standalone CPU Quick Start Guide GFK-3012C April 2018

PACSystems* RX3i IC694ALG232

A PACSystems RX3i Ethernet NIU I/O Station

PACSystems* RX3i CEP IC695CEP001

PACSystems* RX3i and Series IC693MDL940 / IC694MDL940

VersaMax* IC200BEM003. PROFIBUS Master Module. Ordering Information. Specifications. GFK-2739 April of their respective owners.

PACSystems* RX3i and Series 90*-30 IC694ALG223 and IC693ALG223

GE Intelligent Platforms Programmable Control Products

PACSystems* RX3i IC695ACC650

PACSystems* IC695CPE400 RX3i 1.2GHz 64MB Rackless CPU w/field Agent Quick Start Guide GFK-3002A October 2017

PACSystems* RX3i and Series 90*-30 IC694ALG442-CC and IC693ALG442-EC

VersaMax* Serial Communications Module

GFK-2372L September 2015

PACSystems* RX3i IC695CMM002 and IC695CMM004

VersaMax* IC200PNS001, IC200PNS002

PACSystems* RX3i IC695CMM002 and IC695CMM004

PACSystems* RX3i IC695PSA040

GE Fanuc IC695CMM004. Rx3i PacSystem

PACSystems* RXi ICRXIBN0E000A and ICRXIBN0M000A

PACSystems* RX3i IC695PSA140

PACSystems RX3i IC695CPE305. Central Processing Unit. GFK-2714F November 2012

GE Fanuc IC695CPE305. Rx3i PacSystem

PACSystems* RX3i IC695HSC304-DA and IC695HSC308-DA

VersaMax* Analog Input, 16-Bit Thermocouple Module

PACSystems RX3i IC695CPE305. Central Processing Unit. GFK-2714A December Features. Ordering Information

PAC BI-PN-05, 8516-BI-PN-05 and 8752-CA-NS-01

Raising the standard Upgrading the Series 90-30

Standard PACSystems 18-slot Wall (Rear) Mount. 15 Single Width, 8 Double Width (plus one for power supply) RX7i CPU and I/O, VME modules

PACSystems* RX3i IC695PNS001-ABAJ RX3i PROFINET Scanner

PACSystems* RX3i. Important Product Information IC695PNS001. RX3i PROFINET Scanner. GFK-2738L June 2016

PACSystems RX7i IC698CMX016-ED

PACSystems* RX3i IC695PNS001-ABAH RX3i PROFINET Scanner

PACSystems* IC698ACC701C

- Data exchange using configuration-based and logic-based Ethernet Global Data

Analog Input, 16-Bit Thermocouple Module

PACSystems* RX3i IC695CMM002-EG and IC695CMM002CA-EG IC695CMM004-EG, IC695CMM004CA-EG, and IC695CMM004LT-EG

GE Fanuc IC695ETM001. Rx3i PacSystem

PACSystems* RX3i IC695CPU320-HY PACSystems* RX3i CPU

PACSystems RX3i IC695CPU310

IC695CPE330-AAAB RX3i 1GHz 64MB CPU w/ethernet

PACSystems* RX3i IC695ETM001-HU. Ethernet Interface Module. November 2015

Series Specialty PLCs

PACSystems* RX3i IC695CRU320-EY Redundancy CPU

RSTI-EP Slice I/O. EtherCAT Network Adapter Module EPXETC001. GFK-2967B Septembery 2016

PACSystems* RX3i IC695CPU315. Central Processing Unit. Features. Ordering Information. GFK-2586H July 2012

GE Fanuc IC695NKT001. Rx3i PacSystem

PACSystems* RX3i IC695PNC001-AD

PACSystems RX3i IC695CPU310. Features. Ordering Information. Central Processing Unit. GFK-2329T December 18, 2007

PACSystems* RX3i IC695CRU320-EW Redundancy CPU

PACSystems* RX3i IC695PNC001

Current: 0 to 20mA, 4 to 20mA. Voltage: ±10V, 0 to 10V. Isolated +24 VDC Power

SNAP-IT-PM Installation Guide

PACSystems* RX3i IC695PBM300

RSTI-EP Slice I/O. PROFINET Scanner EPXPNS001. GFK-2965C November 2017

Important Product Information

PACSystems RX3i IC695CPU310. Central Processing Unit. Features. Ordering Information. GFK-2329AC May 2011

GE Intelligent Platforms. Programmable Control Products. PACSystems* RX3i. PROFINET Controller Manual, GFK-2571A

SNAP-IT-1U Installation Guide

IMPORTANT PRODUCT INFORMATION

PACSystems RX3i IC695HSC304 and IC695HSC308

USER MANUAL. Longo programmable controller LPC-2.MC8 Main module. Version 10

PACSystems RX3i IC695CMU310

This Datasheet for the IC693ACC301. Replacement Battery, CPU & PCM (qty 1)

Important Product Information

Non-Isolated Analog Output Module with HART Communications, IC695ALG728-DC Non-Isolated Analog Output Modules, IC695ALG704-DC, IC695ALG708-DC

Discrete Output Modules

FloBoss S600+ Field Upgrade Guide

GE Intelligent Platforms. Programmable Control Products. VersaMax. PROFINET Scanner Manual, GFK-2721A

MGate 5111 Quick Installation Guide

Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches. Installation Guide. P/N (Rev G)

MGate 5105-MB-EIP Quick Installation Guide

Important Product Information

PMEUCM Hardware. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA

PACSystems RX3i and Series IC694MDL916 and IC693MDL916 Output Module, Isolated Relay, N.O., 4 Amp, 16 Point

PACSystems RX3i IC695PSA140

PACSystems* RX7i, RX3i and RSTi-EP CPU Reference Manual

This Datasheet is for the IC693ACC301. Backup Battery for RAM Memory.

CTI 2500 QUICK START INSTALLATION GUIDE

This Datasheet for the IC660BBD110. Block 115Vac Input 16 Circuits.

PACSystems RX7i IC698CHS009/119

VersaMax Genius Network Interface Unit

IC695CPE330-AAAG, IC695CPE330CA-AAAG. RX3i 1GHz 64MB CPU w/ethernet

Installation and Configuration Guide

RSTI-EP Slice I/O. Digital Output Module

VersaMax* PROFIBUS Network Interface Unit

P3-RS Remote Slave Module

PACSystems* RX3i Genius* Communications Gateway User Manual

PACSystems* RX3i IC695CMM002-EJ and IC695CMM002CA-EJ IC695CMM004-EJ, IC695CMM004CA-EJ, and IC695CMM004LT-EJ Serial Communications Modules

Transcription:

GE Intelligent Platforms Programmable Control Products PACSystems* RX3i Central Processing Unit IC695CPE305 Quick Start Guide GFK-2934A August 2015

Contents 1. User Features... 1 1.1. Switches... 3 1.2. Real-Time Clock Battery... 4 1.3. Ethernet Port... 4 1.4. Serial Port... 5 1.5. Removable Data Storage Devices (RDSDs)... 5 1.6. Energy Pack... 5 1.7. Light-Emitting Diode Indicators (LEDs)... 6 2. Hardware Installation... 8 2.1. Initial Checks... 8 2.2. Installation Location... 8 2.3. Installation in Hazardous Areas... 9 3. Module Initial Startup... 11 4. Additional Information... 13 i PACSystems* RX3i Central Processing Unit IC695CPE305Quick Start Guide GFK-2934A

1. User Features The PACSystems* RX3i CPE305 can be used to perform real time control of machines, processes, and material handling systems. The CPU communicates with the programmer via the internal Ethernet port or a serial port. It communicates with I/O and Intelligent Option modules over a dual PCI/Serial backplane. Contains 5 Mbytes of user memory and 5 Mbytes of nonvolatile flash user memory. Battery-less retention of user memory. Energy Pack IC695ACC400 on system power loss powers CPU long enough to write user memory to non-volatile storage (NVS). Configurable data and program memory. Programming in Ladder Diagram, Structured Text, Function Block Diagram, and C. Supports auto-located Symbolic Variables that can use any amount of user memory. Reference table sizes include 32Kbits for discrete %I and %Q and up to 32Kwords each for analog %AI and %AQ. GFK-2934A August 2015 1

Supports most Series 90-30 modules and expansion racks. For supported I/O, Communications, Motion, and Intelligent modules, refer to the PACSystems RX3i Hardware and Installation Manual, GFK-2314. Supports up to 512 program blocks. Maximum size for a block is 128KB. An RS-232 serial port. Embedded Ethernet interface supports up to 32 simultaneous SRTP Server connections, up to 16 simultaneous Modbus/TCP Server connections, and up to 16 simultaneous communications channels of either SRTP Channels or Modbus/TCP Client channels. For details, refer to the PACSystems RX7i & RX3i TCP/IP Ethernet Communications User Manual, GFK-2224. Effective with firmware version 8.20, this product supports OPC-UA. Effective with firmware version 8.30, this product supports Ethernet Global Data, Class 1. Effective with firmware version 8.50, this product supports HART Pass Through. Time synchronization to SNTP Time Server on Ethernet network when used with a rack-based Ethernet module (IC695ETM001) version 5.0 or later. Ability to display serial number and date code in programmer Device Information Details. Ability to transfer applications to and from USB 2.0 A type removable data storage devices, or RDSDs. Compliant with EU RoHS Directive 2002/95/EC using the following exemptions identified in the Annex: 7(a), 7(c)-I and III, and 15. HART is a registered trademark of the HART Communication Foundation of Austin, Texas USA. Any use of the term HART hereafter in this document, or any document referenced by this document, implies the registered trademark. 2 PACSystems* RX3i Central Processing Unit IC695CPE305Quick Start Guide GFK-2934A

1.1. Switches The RDSD and Run Mode switches are located behind the front protective door. The Reset switch is not used. Switch operation is given in the following table. Switch Operation RDSD Switches Start pushbutton Three-position switch Upload Off Download Run Mode Switch Function Pressing this switch initiates RDSD data transfer. (The three-position switch must be set to Upload or Download.) Enables/disables RDSD data transfer and selects the direction of data transfer. Loads application from CPU to RDSD. Disables RDSD data transfer. Stores application from RDSD to CPU. A three-position switch which operates as follows: Switch Position CPU and Sweep Mode Memory Protection The CPU runs with I/O sweep User program memory is Run I/O Enable enabled. read only. The CPU runs with outputs User program memory is Run Output Disable disabled. read only. The CPU is not allowed to go User program memory Stop into Run mode. can be written. The Run Mode switch can be disabled in the programming software in Hardware Configuration (HWC). The switch s memory protection function can be disabled separately in HWC. The Run Mode switch is enabled by default. The memory protection functionality is disabled by default. GFK-2934A August 2015 3

1.2. Real-Time Clock Battery The CPE305 is shipped with a real time clock (RTC) battery (IC690ACC001) installed, with a pull-tab on the battery. The pull tab should be removed before installing the CPE305. There are no diagnostics or indicators to monitor RTC battery status. The RTC battery has an estimated life of 5 years and must be replaced every 5 years on a regular maintenance schedule. If the RTC battery fails, the CPU date and time is reset to 12:00 AM, 01-10- 2000 at startup. The CPU operates normally with a failed or missing RTC battery; only the initial CPU Timeof-day (TOD) clock information will be incorrect. 1.3. Ethernet Port The embedded Ethernet interface supports communications with the Machine Edition programming software using the proprietary SRTP protocol. The CPE305 CPU provides two SRTP-server connections. The embedded Ethernet interface has one RJ-45 Ethernet port that automatically senses the data rate (10Mbps or 100Mbps), duplex status (half or full duplex), and cabling arrangement (straight through or crossover) of the attached link. 4 PACSystems* RX3i Central Processing Unit IC695CPE305Quick Start Guide GFK-2934A

1.4. Serial Port The CPE305 provides one RS-232 serial interface to external devices. This port can be used for firmware upgrades. The port is electrically isolated. For serial port pin assignments and details on serial communications, refer to the PACSystems RX3i and RX7i CPU Reference Manual, GFK-2222. The RS-232 port does not supply the 5VDC power offered by other RX3i and Series 90-30 CPUs. Cable IC693CBL316 must be used for RS-232 serial connections to the CPE305. 1.5. Removable Data Storage Devices (RDSDs) The CPE305 provides the ability to transfer applications to and from an RDSD (USB compatible device, such as a memory stick, smart phone, digital camera or MP3 device). Once the data is copied to the RDSD, it can be written to other RX3i CPE305 CPUs with no programmer software needed. The RDSD interface requires a usersupplied flash memory device that complies with the USB 2.0 Specification. The USB port must be enabled in the RX3i configuration in order to transfer data between the CPU and the RDSD. The CPE305 is shipped with the RDSD (USB) port enabled. Complete details of the use of RDSDs are found in the PACSystems RX3i and RX7i CPU Reference Manual, GFK-2222. 1.6. Energy Pack The CPE305 preserves user memory using an Energy Pack without the need to periodically replace batteries. The IC695ACC400 Energy Pack powers the CPU long enough for the CPU to write its user memory contents to the CPU s non-volatile storage during a system power loss. Installation of the Energy Pack is found below. GFK-2934A August 2015 5

1.7. Light-Emitting Diode Indicators (LEDs) OK indicates module readiness to perform normal operations. Green, ON steady OFF Green, blinking RN indicates the run state of the CPU. Green, ON steady OFF Green, blinking in unison with OK EN indicates outputs enabled. CPU passed power-up diagnostics, functioning properly Power is not applied or CPU has a problem, which may be indicated by RN and EN blink pattern CPU in Stop-Halt state; possible watchdog timer fault. Refer to the fault tables. If the programmer cannot connect, cycle power with a charged Energy Pack attached and refer to fault tables CPU is in Run mode. CPU is in Stop mode. CPU is in boot mode and is waiting for a firmware update through a serial port. Green, ON steady OFF Output scan is enabled. Output scan is disabled. CM indicates activity on the serial communications port. Green, blinking OFF Signal activity on the COM1 port. No activity on COM1 port. IO FORCE indicates override on a bit reference. Amber, ON steady OFF Override active on at least one bit reference. No overrides applied. 6 PACSystems* RX3i Central Processing Unit IC695CPE305Quick Start Guide GFK-2934A

STATUS indicates Energy Pack status. OFF Green, blinking Red, ON Red, blinking Green, ON steady SYS FLT indicates presence of a fatal fault. OFF Red, ON Energy Pack not connected. Energy Pack charging; not yet charged above the minimum operating voltage. Energy Pack circuit fault. Energy Pack near its end of life and should be replaced soon. Energy Pack is charged above its minimum operating voltage. No fatal faults. CPU is in Stop/Faulted mode because a fatal fault has occurred. RDSD indicates signal activity on the RDSD/COM2/USB port. Green, blinking OFF COM2 port activity No COM2 port activity GFK-2934A August 2015 7

2. Hardware Installation 2.1. Initial Checks Upon receiving your RX3i equipment, carefully inspect all shipping containers for damage. If any part of the system is damaged, notify the carrier immediately. The damaged shipping container should be saved as evidence for inspection by the carrier. As the consignee, it is your responsibility to register a claim with the carrier for damage incurred during shipment. GE Intelligent Platforms will fully cooperate with you, however, should such action be necessary. After unpacking the RX3i equipment, record all serial numbers. Serial numbers are required if you should need to contact Customer Care during the warranty period. All shipping containers and all packing material should be saved should it be necessary to transport or ship any part of the system. Verify that all components of the system have been received and that they agree with your order. If the system received does not agree with your order, contact Customer Care. 2.2. Installation Location This product is intended for use with the RX3i system. Its components are considered open equipment (having live electrical parts that may be accessible to users) and must be installed in an ultimate enclosure that is manufactured to provide safety. As a minimum, the enclosure shall provide a degree of protection against solid objects as small as 12mm (e.g. fingers). This equates to a NEMA/UL Type 1 enclosure or an IEC60529 IP20 rating providing at least a pollution degree 2 environment. For details about installing RX3i rack systems, refer to the PACSystems RX3i System Manual, GFK-2314. If you need technical help, contact Technical Support. For phone numbers and email addresses, see the back cover of this Guide. 8 PACSystems* RX3i Central Processing Unit IC695CPE305Quick Start Guide GFK-2934A

2.3. Installation in Hazardous Areas The following information is for products bearing the UL marking for Hazardous Areas or ATEX marking for explosive atmospheres: CLASS 1 DIVISION 2 GROUPS ABCD ATEX Zone 2 This equipment is an open-type device and is meant to be installed in an enclosure suitable for the environment that is only accessible with the use of a tool. Suitable for use in Class I, Division 2, Groups A, B, C and D Hazardous Locations, or nonhazardous locations only. Warning EXPLOSION HAZARD - SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2. Warning WHEN IN HAZARDOUS LOCATIONS, TURN OFF POWER BEFORE REPLACING OR WIRING MODULES; AND Warning DO NOT CONNECT OR DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NONHAZARDOUS. Warning EXPLOSION HAZARD - USB PORT IS ONLY FOR USE IN NONHAZARDOUS LOCATIONS, DO NOT USE UNLESS AREA IS KNOWN TO BE NON-HAZARDOUS. This product must be mounted in an enclosure certified in accordance with EN60079-15 for use in Zone 2, Group IIC and rated IP54. The enclosure shall only be able to be opened with the use of a tool. 2.4. Module Installation For initial startup and configuration of the CPE305, complete the following steps. For full details on CPE305 operation, refer to the PACSystems RX3i and RX7i CPU Reference Manual, GFK-2222. 1. Remove the pull-tab from the Real Time Clock (RTC) battery, located on the back of the CPE305. GFK-2934A August 2015 9

2. Remove power from the RX3i rack and install the CPE305. The CPE305 may be installed in any slot in the RX3i Main rack, except the highest-numbered slot or slot 0. 3. Holding the module firmly, align the module with the correct slot and connector, then swing the module down until the module s connector engages the backplane s backplane connector. Visually inspect the module to be sure it is properly seated. 4. Insert the two provided M3x5mm machine screws through the module s bottom bracket into threaded holes in the bottom of the backplate and screw them several turns using a #1 Phillips screwdriver. Tighten to 0.7 N-m (6 in-lbs). 5. Mount the Energy Pack on the left side of the module in slot 0 of the rack (typically a power supply). a. Engage the Energy Pack s mounting hooks (at the top) on the frame of the leftmost module. b. Rotate the bottom of the Energy Pack into place, engaging the bottom hooks. The latch will snap into place. c. Connect cable IC695CBL001 from the connector on the bottom of the Energy Pack to d. the corresponding connector on the bottom of CPE305. 6. If required, connect the CPE305 to the Ethernet network. 7. Apply power to the rack. 10 PACSystems* RX3i Central Processing Unit IC695CPE305Quick Start Guide GFK-2934A

Note: When the Energy Pack is powered up for the first time, or is in a system that has been powered down long enough to completely discharge the Energy Pack, it may require a few seconds for it to charge to its operating level. The CPU s STATUS LED will blink green during this time. 3. Module Initial Startup You Will Need: PACSystems RX3i CPU Firmware 8.00 or later. Proficy* Machine Edition configuration and programming software, version 8.0 or later. A IC693CBL316 serial or Ethernet cable for connecting the computer running the Proficy Machine Edition programmer to the RX3i CPU. Initial Configuration 1. Using Proficy Machine Edition (PME) software, configure the CPE305 in an RX3i target. Note: If you intend to use the module s embedded Ethernet interface, you will probably need to assign it a new IP address. To configure the embedded Ethernet interface in Machine Edition, expand the CPU slot to display the Ethernet daughterboard. The Settings tab for the embedded Ethernet module contains IP Address, Subnet Mask and Gateway IP Address (see the following diagram). Consult your network administrator for the proper values for these parameters. GFK-2934A August 2015 11

Configuration of the Ethernet Port on CPE305 2. Go online with the target and download the configuration. You can use one of the following methods for the initial connection to the CPE305: a. Using an IC693CBL316 cable, connect to the module s RJ-25 RS-232 serial port to the programmer computer. The computer must be equipped with an RS-232 serial port with a standard AT-style nine-pin male D-connector. b. Connect to the module s Ethernet port, using the factory-loaded IP address, 192.168.0.100. Note: This address is intended only for initial connection in order to complete the configuration. After the initial configuration download, must be changed before connecting to the Ethernet network. When you store a hardware configuration with a different IP address, the temporary IP address is lost; it is not restored by a Clear operation. c. Through the Ethernet connection of an ETM001 in the same rack with a known IP address configuration. 12 PACSystems* RX3i Central Processing Unit IC695CPE305Quick Start Guide GFK-2934A

4. Additional Information PACSystems RX3i and RX7i CPU Reference Manual PACSystems RX3i and RX7i CPU Programmer s Reference Manual PACSystems RX3i System Manual PACSystems RX3i IC695CPE305 CPU Important Product Information GFK-2222 GFK-2950 GFK-2314 GFK-2714 User manuals, product updates and other information sources are available on the Support website, http://www.ge-ip.com/support, under Controllers and IO, RX3i Controllers. GFK-2934A August 2015 13

g GE Intelligent Platforms Contact Information Americas: 1-800-433-2682 or 1-434-978-5100 Global regional phone numbers are available on our web site www.ge-ip.com Copyright 2014-2015 General Electric Company. All Rights Reserved. * Trademark of General Electric Company and/or its subsidiaries. All other trademarks are property of their respective holders GFK-2934A