Operating Instructions. DALI-Gateway

Similar documents
Electrical devices may only be mounted and connected by electrically skilled persons.

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions

Operating Instructions. Power-DALI-Potentiometer

1 Safety instructions. 2 Device components. 3 Function. Control unit 1-10 V, 3-gang. Art.-No.: 2193 REG. Operationsmanual

Operating Instructions

KNX DALI Gateway Plus - User Manual

1 Safety instructions. 2 Device components. 3 Function. Control unit, 1-10 V 3-gang. Order-No. : Operating instructions

1 Safety instructions. 2 Device components. 3 Function. DALI transformer W. Art.-No.: D SNT 105. Operationsmanual

Four-channel Venetian blind actuator 230 V Installation Instructions

picture 1: Device components

KNX/EIB KNX Blind actuator. 1 Safety instructions. 2 Device components. Blind actuator 4-gang 24 V DC Order-No. :

Product documentation

Figure 1: Device components

Product documentation

Product documentation

1-channel shutter actuator 6A UP Installation Instructions

KNX/EIB Flush-mounted universal dimming actuator 210 W. 1 Safety instructions. 2 Device components. Order-No. : Operating instructions

1 Safety instructions. 2 Device components. 3 Function. DALI Tronic transformer 105 W. Order-No. : Operating instructions

Structure of the device. Push-button sensor module. Ref.-no.: 4008 TSM Safety instructions

4-gang and 8-gang switch actuator 16A C-load SE

1 Safety instructions. 2 Device components. KNX Touch/Glass sensor comfort

Mounting instructions Flush box of Flat Panel PC

Universal dim actuator 1gang RMD Universal dim actuator 2gang RMD Universal dim actuator 4gang RMD

Operating and mounting instructions

1 Safety instructions. 2 Device components. 3 Function. Smart Control IP. Art. No. SC 1000 IP. Operating instructions

KNX/EIB Push button sensor 3 Plus F Safety instructions. 2 Device components. 3 Function

picture 1: Device components

Product documentation

Product and functional description

Control unit for lux control, MDRC Type: SL/S 50.1, GH Q R0001

ABB i-bus KNX DALI Light Controller, 8-fold, MDRC DLR/S M, 2CDG110101R0011

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Product documentation

DALI Professional Controller-4. Control unit Operating instructions

Product Information. DCM Standard indoor stations TK IS A 514 A.. TK IS A 514 AD.. (Design)

The output variables can be force-controlled from a coordinating control system.

The LED display (1) turns green when the load is switched on.

Lighting Control System for Indoor Applications LIGHT CONTROLLER L LIGHT CONTROLLER L

Product and functional description

Installation Instructions

1 Safety instructions. 2 Device components. Smart Panel. Art.-No.: SP 9 KNX. Operating instructions

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. LB management. Universal rotary dimmer LED

Product and functional description

Product and functional description

Switch/shutter actuator 8/4gang 16A RMD Switch/shutter actuator 16/8gang 16A RMD

Blind actuator 4-gang 230 V AC Order-No

Docking station Order no Operation and installation instructions. 1 Safety instructions. 2 Structure of the device.

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

KNX/EIB Product documentation. Page 1 of 23. Order-No xx Order-No xx Order-No xx Order-No xx

Operating Instructions

UNIVERSAL DIMMER DIM02SA/500U

UNIVERSAL DIMMER DIM02SA/500U

UNIVERSAL DIMMER DIM04SA/500U

Product and functional description

Bus coupler 3 Bus coupler 3 external sensor Order No

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012

SMS 3xxx/SMS 4xxx Safety switch with separate actuator

Product documentation

Push Button Interface UP 220D31

Data sheet. Function description. Benefits

Lighting Control System for Indoor Applications LIGHT CONTROLLER LW RADIO-OPERATED VERSION ENOCEAN RADIO-OPERATED CONTROLLER

MINI-PS AC/10-15DC/8

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

- Pt100 temperature relay for up to 12 sensors with electric 10 MBit/s Ethernet interface Configuration through Web server

An optional analog input module, Order no connected to a 6-pole system connector adds four more analog sensors to the device.

Product and Applications Description

COMPACT LED DRIVERS. PrimeLine DALI dimmable & Selectable Current (Dip Switch) PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH)

Product and functional description

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Power Supply System KNX PS640-IP

IP gateway, MDRC IG/S 1.1, GH Q R0001

Original operating instructions Safety relay with relay outputs G1501S / / 2016

LINEAR LED DRIVERS. PrimeLine DALI dimmable. PrimeLine DALI DIMMABLE , , , , ,

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX

Operating Instructions VEGAMET 381

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Power Supply Systems KNX PS640 and KNX PS640 USB

Water-protected surface-mounted push-button bus coupler Order No , , ,

Data sheet. Constant current DALI LED control gear 80 W Output power ma Output current Intelligent temperature protection.

Operating instructions

ABB i-bus KNX Switch Actuator, Current Detection, x-fold, 16/20 A, C-Load, MDRC SA/S x , 2CDG1101xxR0011

KNX/EIB Product documentation. Issue:

Positioning modules with DC V output signals, and storage of positioning value

Product documentation

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Switching module for AC V and up to three load stages, with manual switching

COMPACT LED CONVERTERS 48 V

Siemens Spares. RL 513D23 Switching actuator (relay), 3 x 6A. Technical Product Information

ABB i-bus KNX DALI Gateway Emergency Lighting DGN/S Product Manual

Intelligent Light Control System for Indoor Applications

The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal.

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Line Coupler, MDRC LK/S 3.1, GH Q R0001

Status display unit with P-bus connection

AS-i Safety Analog Input Module, IP20

LED Driver Compact fixed output

PHOENIX CONTACT - 07/2006

Blu2Light Light Management Installation in Luminaires

Transcription:

Operating Instructions 1. Safety instructions Electrical equipment must be installed and fitted by qualified electricians only. Failure to observe the instructions may cause damage to the device and result in fire or other hazards. The device is not suited for safe disconnection of the mains supply. The DALI control voltage is a functional extra-low voltage (FELV). Safe separation between KNX/EIB and DALI in installations must be ensured. These operating instructions are part of the product and must be left with the final customer. 2. Device components Stand: Aug-07 825 599 03

(1) buttons for manual control (2) programming button and LED (3) KNX bus terminal (4) DALI group display (5) mains supply terminal (6) DALI output 3. Function System information This device is a product of the KNX-system and complies with KNX directives. Technical knowledge obtained in KNX training courses is a prerequisite to proper understanding. The functionality of this device depends on the software. Detailed information on loadable software and attainable functionality as well as the software itself can be obtained from the manufacturer s product database. Planning, installation and commissioning of the unit is effected by means of KNX-certified software. The full functionality with KNX commissioning software from version ETS3.0d. onwards. The product database, technical descriptions and conversion programs and other utilities are available in the Internet at www.jung.de. Designated use Controlling of luminaires and other applications with DALI devices in KNX installations, e.g. electronic ballasts. Installation on DIN rail in small distribution boards Product features Controlling of 64 DALI devices max. in 32 groups max. 16 light-scenes Readout of the DALI device status via the KNX, e.g. brightness, luminaire malfunction. Manual control of the DALI groups Forced control Checkback of switching status and brightness level in bus and manual control mode Central switching function Disabling function for each group Separate ON and OFF delays Staircase lighting application with early-warning function DALI commissioning with ETS plug-in Short-circuit protection Overload protection Over-voltage protection Replacement of a single DALI device in operation possible without software State of delivery: provisional operation, control of DALI groups via keypad possible. All DALI devices are controlled in common. 2

4. Operation (4) DALI group display (1...32) (7) key Manual control mode (8) LED ON: permanentle manual control active (9) key ON/ Switching on or increasing brightness (10) LED ON/ on: DALI group activated, brightness 1..100% (11) key OFF/ Switching off or reducing britghtness (12) LED OFF/ on: DALI group deactivated, brightness 0 % (13) key ALL OFF Deactivating all DALI group Control modes Bus mode: operation from touch sensors or other bus devices Temporary manual control mode: manual operation locally with keypad, automatic return to bus mode Permanent manual control mode: only manual control locally on device Bus operation in manual control mode disabled. Manual control in the event of bus failure enabled. After failure and return of bus voltage, the device switches over to the bus mode. After failure and return of mains voltage, the device switches over to the bus mode. Manual control mode can be disabled in operation via bus telegram. Activating the temporary manual control mode Keypad operation is programmed and not disabled. Press the key briefly < 1 s. 01 is displayed, LED remains off. - or - bc is displayed: The device is not programmed; all DALI devices connected are controlled in common. In this broadcast mode it is not possible to control DALI devices individually. 3

After 5 s without key-press, the device returns automatically to the bus mode. Deactivating the temporary manual control mode The device is in the temporary manual control mode. No key-press for 5 s. - or - Press the key briefly < 1 s several times until the device quits the temporary manual mode. The display is off. Activating the permanent manual control mode Keypad operation is programmed and not disabled. Press the key for at least 5 s. The LED is on, 01 is displayed, the permanent manual control mode is activated. - or - bc is displayed: The device is not programmed; all DALI devices connected are controlled in common. In this broadcast mode it is not possible to control DALI devices individually. Deactivating the permanent manual control mode The device is in the permanent manual control mode. Press the key for at least. The LED is off, display is off, bus mode is activated. Controlling the DALI groups The device is in the permanent or temporary manual control mode. Press the key several times briefly < 1 s until the desired group is displayed. The ON/ and OFF/ LEDs indicate the status. Controlling the DALI group with the ON/ or / key brief press: on/off long press: increase / reduce brightness release: dimming stop LEDs ON/ and OFF/ indicate the status. Deactivating all DALI groups The device is in the permanent manual control mode. Press the ALL OFF key. All DALI groups are deactivated. Disabling individual DALI groups The device is in the permanent manual control mode. Press the key several times briefly < 1 s until the desired group is displayed. The status is indicated by the ON/ and OFF/ LEDs. Press the ON/ and OFF/ simultaneously for at least 5s. The number of the selected DALI group flashes. The DALI group is disabled. Activate the bus mode (deactivate the permanent manual control mode). A disabled DALI group can be operated in the manual control mode. 4

Re-enabling DALI groups The device is in the permanent manual control mode. Press the key several times briefly < 1 s until the desired group display flashes. Press the ON/ and OFF/ keys simultaneously for at least 5 s. The selected DALI group is re-enabled. The display stops flashing. Activate the bus mode (deactivate the permanent manual control mode). 5. Information for qualified electricians DANGER! Electric shock in case of accidental contact with live parts. Electric shocks may be fatal. Before working on the device, cut out the mains supply and cover up live parts in the surroundings. 5.1. Fitting and electrical connection Fitting the device Observe the temperature range (Technical data). Ensure sufficient cooling. Fit the device by snap-fastening on a mounting rail in acc. With DIN EN 60715. The connecting terminals must be at the top. Electrical connection DALI devices from some manufacturers have enlarged functions and can be controlled by means of a mains voltage at the DALI terminal. When retrofitting existing DALI installations, remove all corresponding circuits. The DALI control voltage is a functional extra-low voltage (FELV). Plan the installation in such a way that all lines carrying DALI 5

voltage as well as mains voltage are disconnected when the supply to a sector is disconnected. Connect the device (Fig. 3). Connect the bus line to the bus terminal. DALI devices can be connected to different phase conductors. Sliding on the protective cap 4A 4B To protect the bus lines against dangerous voltages at the connecting terminal, slide on the protective cap. Lead out the bus line at the rear of the device. Slide the cap over the bus terminal (Fig. 4A) until it is heard to engage Removing the cap Press the sides of cap and withdraw (Fig. 4B). 5.2. Commisioning Loading the address and the application software Switch on the mains voltage (switch on the automatic circuit breaker). Switch on the bus voltage. Allocate the physical address. Put the DALI system into operation with the commissioning software. For further details refer to the product documentation. Download the application software into the device. Programming is not possible if the mains voltage is not connected. 6

6. Technical data KNX medium TP1 Mode of commissioning S-Mode (ETS) KNX supply 21...32 V DC KNX power consumption typically 150 mw Mains supply 110...240 V AC ±10% Mains frequency: 50/60 Hz Total dissipated power max. 3 W Number of DALI devices max. 64 (power consumption 2 ma each) DALI voltage typically 16 V DALI transmission rate 1200 bit/s DALI protocol DIN EN 60929 Annex E4 Line length Gateway Device with line cross-section 1.5 mm² max. 300 m with line cross-section 1.0 mm² max. 238 m with line cross-section 0.75 mm² max. 174 m with line cross-section 0.5 mm² max. 116 m Resistance of DALI line max. 4 Ώ single length (8 Ώ return length) DALI line type not specified (2 free wires in NYM cable) KNX connection connecting terminal DALI connection screw terminals single-wire 0.2...4 mm² or 2 x 0.2...2.5 mm² stranded wire without ferrule 0.75...4 mm² stranded wire with ferrule 0.5...2.5 mm² Ambient temperature -5 C...+45 C Storage temperature -25 C...+70 C Mounting width 72 mm (4 modules) Accessories Cap Ref.-no. REG KAP 6.1. Help in case of troublel Display shows Er, connected DALI devices not operational, control not possible Cause: mains voltage on DALI line. Installation faulty; remove mains and bus voltage from device and from other connected DALI devices; correct faulty installation. 7

Display shows bc in manual control mode; controlling of individual luminaires not possible. Cause: The device is not programmed. Program the device, put the DALI system into operation. Individual DALI device not operational Cause 1: consumer defective, e.g. lamp. Replace the consumer. Cause 2: DALI device defective. Replace defective DALI device. Switch on the power supply. Press the and the ALL OFF keys together for at least 10s. The identifies the replaced DALI device and downloads the required data into the device. The display shows LE. Simultaneous replacement of several DALI devices only with commissioning software and project data. Manual control with keypad not possible Cause 1: manual control mode not programmed. Reprogram the device, activate the manual control. Cause 2: manual control disabled via the bus. Enable the manual control mode. DALI group control not possible Cause: DALI group disabled via the bus or via manual control. Re-enable the output. None of the DALI groups operational Cause 1: all DALI groups disabled via the bus or via manual control. Re-enable the output. Cause 2: permanent manual control is activated. Deactivate the permanent manual control mode. Cause 3: application software stopped, programming LED flashing. Make a reset: disconnect the device from the bus, reconnect after 5 seconds. Cause 4: no or faulty application software. Check programming and rectify. 8

7. Guarantee Our products are under guarantee within the scope of the statutory provisions. Please return the unit postage paid to our central service department giving a brief description of the fault: ALBRECHT JUNG GMBH & CO. KG Service-Center Kupferstr. 17-19 D-44532 Lünen Service-Line: +(49) 23 55. 80 65 51 Telefax: +(49) 23 55. 80 61 65 E-Mail: mail.vka@jung.de General equipment Service-Line: +(49) 23 55. 80 65 55 Telefax: +(49) 23 55. 80 62 55 E-Mail: mail.vkm@jung.de KNX equipment Service-Line: +(49) 23 55. 80 65 56 Telefax: +(49) 23 55. 80 62 55 E-Mail: mail.vkm@jung.de The -Sign is a free trade sign addressed exclusively to the authorities and does not include any warranty of any properties. 9