ectd Next Major Release Business Requirements Collation (11 NOV 10) TOPIC Requirement Comment ICH Req No.

Similar documents
ectd Next Major Release Business Requirements Collation (9-JUN-10) TOPIC Requirement Comment

ectd Next Major Version Business Requirements (11-JUN-09)

RPS/ICH Requirements. sequence number values would need to be unique to each application. principle. 1 of 14

Orientation Material for M8: ectd EWG ectd v4.0 Implementation Package v1.3

Get ready for ectd in South Africa. Current status at MCC

ectd : Industry Experience

1. Document Control 2. Change Record Version Date Author(s) Comments 3. Reviewers Version Name Organisation 4. Distribution Version Date Name Status

1 2 December esubmissions? 1. How can baseline dossiers support global esubmissions? Disclaimer. What is a baseline submission?

MEDICINES CONTROL COUNCIL

INTERNATIONAL COUNCIL FOR HARMONISATION OF TECHNICAL REQUIREMENTS FOR PHARMACEUTICALS FOR HUMAN USE

Work instructions for US-FDA ANDA Submissions Work Instructions for ectd US-FDA ANDA Submissions

Variations in ectd format Q&A document

GDUFA s Impact on ectds / Case Study: Implementing PDF Standards

Release Notes for TIGes ectd Guidance Comparison of version 2.0 with 1.0

US Food and Drug Administration. Revision History

Steps to RPS Adoption

THE OECD GLOBAL HARMONIZED SUBMISSION TRANSPORT STANDARD (GHSTS) PROJECT

M2 Glossary of Terms and Abbreviations

Guidance for electronic and paper submissions for Certificates of Suitability (CEP) applications

ectd Next Major Version / Regulated Product Submission

ICH Topic M 4 Common Technical Document for the Registration of Pharmaceuticals for Human Use Organisation CTD. Step 5

Guidance for electronic submissions for Certificates of Suitability (CEP) applications

Get ready for ectd in South Africa

ectd in Canada Ginette Larocque, Purdue Pharma Canada August 23, 2016

ICH M8 Expert Working Group. Specification for Submission Formats for ectd v1.1

A CMC Reviewer s Perspective on the Quality Overall Summary. Arthur B. Shaw, Ph.D. FDA/CDER/ONDQA FDA DMF Expert June 15, 2010.

ectd TECHNICAL CONFORMANCE GUIDE

Update of ectd Module 1 specification for South Africa V2.0

Administrative Guideline. SMPTE Metadata Registers Maintenance and Publication SMPTE AG 18:2017. Table of Contents

MEDICINES CONTROL COUNCIL

Criteria Webinar. 13 th July European Update on Validation of ectd & NeeS submissions, July 2012

Guideline on the specifications for provision of an electronic submission (e-submission) for a veterinary medicinal product

ectd Practical experiences of the ectd pilot project and way forward

TH ectd Specification

1 Supported Validation Sets

EU Module 1 v1.4 Release Notes August 2009

About Domestic Implementation of the Electronic File Specifications to Be Included in the ICH Electronic Common Technical Document (ectd) v1.1.

The ectd Backbone Files Specification for Module 1. The ectd BACKBONE FILES SPECIFICATION FOR MODULE 1

Revision of Technical Conformance Guide on Electronic Study Data Submissions

ICH M2 REDACTION: POINTS TO CONSIDER

CDASH Standards and EDC CRF Library. Guang-liang Wang September 18, Q3 DCDISC Meeting

EMEA IMPLEMENTATION OF ELECTRONIC ONLY SUBMISSION AND ectd SUBMISSION:

ANSM 11/ Page 1 sur 6

Guidance for Industry on Providing Regulatory Information in Electronic Format: ectd electronic Submissions

ectd Tools Compatibility and Interoperability: Discussion and Practical Experience

Biotechnology Industry Organization 1225 Eye Street NW, Suite 400 Washington, DC 20006

Important Notes: The XML and there corresponding images should be added with the proper file names.

Indexing Field Descriptions Recommended Practice

Pharmaceuticals, Health Care, and Life Sciences. An Approach to CDISC SDTM Implementation for Clinical Trials Data

esubmission Gateway and Web Client Training on the use of XML delivery files for Veterinary submissions

Preparing for FDA Mandated ectd Submissions

Improving Metadata Compliance and Assessing Quality Metrics with a Standards Library

Change Control Process for European ectd Standards Version 1.1. December 2006

ICH M8 Expert Working Group. ICH Electronic Common Technical Document (ectd) v4.0 DRAFT ICH Implementation Guide v2.0

European Medicines Agency Standard Operating Procedure

MedDRA Update. MedDRA Industry User Group Meeting. 28 September 2018

ETSI TS V8.0.0 ( ) Technical Specification

Memorandum. This memorandum requires Board action. EXECUTIVE SUMMARY

Edwin Ponraj Thangarajan, PRA Health Sciences, Chennai, India Giri Balasubramanian, PRA Health Sciences, Chennai, India

Helping The Define.xml User

Information Technology Metadata registries (MDR) Part 6: Registration

-Evolving ectd Technology Transforming Global Regulatory Submission Strategy. PART TWO 30-Mar ectd MASTERCLASS 1

DATA ITEM DESCRIPTION

Site User Guide. Oracle Health Sciences InForm CRF Submit Release Part Number:E

FDA XML Data Format Requirements Specification

ICH M8 Expert Working Group. ICH Electronic Common Technical Document (ectd) v4.0 Implementation Guide v1.2

How to create a validated ectd submission based on the new guidelines and specification - Part 1

Customer Guidance For Requesting Changes to SNOMED CT

The Dublin Core Metadata Element Set

Software Requirements Specification. <Project> for. Version 1.0 approved. Prepared by <author(s)> <Organization> <Date created>

ISO/IEC INTERNATIONAL STANDARD. Information technology Software asset management Part 2: Software identification tag

Introduction to ADaM and What s new in ADaM

Records Management Metadata Standard

Material covered in the Dec 2014 FDA Binding Guidances

GEOFidelis SDSFIE Implementation Roles and Responsibilities Guide

Pre-notification check for type IB Variations 1

DATA Act Information Model Schema (DAIMS) Architecture. U.S. Department of the Treasury

Standard CIP 005 2a Cyber Security Electronic Security Perimeter(s)

Step: 9 Conduct Data Standardization

April 28, Division of Dockets Management (HFA-305) Food and Drug Administration 5630 Fishers Lane, Room 1061 Rockville, MD 20852

extended EudraVigilance Medicinal Product Report Message (XEVPRM) Step-by-Step Guide

Medical devices Quality management Medical device nomenclature data structure

Biocides Submission Manual How to use the SPC Editor

PSUR Repository Interactive Q&A

Agilent ICP-MS ChemStation Complying with 21 CFR Part 11. Application Note. Overview

December EMA/668616/2014-Rev.2.4EMA/668616/2014-Rev.2.5

How to handle different versions of SDTM & DEFINE generation in a Single Study?

GMEI UTILITY BULK REGISTRATION AND RENEWAL USER'S GUIDE FOR TEMPLATE VERSION 5.4 JANUARY 29, 2018

Biocides Submission Manual

extended EudraVigilance Medicinal Product Dictionary (XEVMPD) e-learning

Guidance for Industry on Providing Regulatory Information in ectd Format

The Wonderful World of Define.xml.. Practical Uses Today. Mark Wheeldon, CEO, Formedix DC User Group, Washington, 9 th December 2008

PROPOSED DOCUMENT. International Medical Device Regulators Forum

EUROPEAN MEDICINES AGENCY (EMA) CONSULTATION

eprotocol - Protocol Management System (PMS) Reviewer User Guide Version 2.0

Archivists Toolkit: Description Functional Area

GEP Certificate Database System - User Manual Contents

Submitting High Quality ectd Submissions to FDA/OGD

PMS Iteration 1: analysis of the data efforts & value results and recommendation on the scope

Comparison of FDA and PMDA Requirements for Electronic Submission of Study Data

Transcription:

ICH Req No. ICH001 ICH002 ICH003 ICH004 ectd Next Major Release Business Requirements Collation (11 NOV 10) TOPIC Requirement Comment A regulated product application may have one or more regulatory activities associated with it It must be possible to define a 'Regulatory Activity' to which a group of sequences will belong A regulatory activity may have one or more sequences associated with it The message should support the ability to provide one sequence to multiple regulatory activities which may span more than one application. sequence number values would need to be unique to each application ICH005 Each sequence should have a unique identifier ICH006 Capability to identify which ectd sequences were used at which step of agency review. ICH007 The message should not restrict adoption/implementation of the standard at any point in a product's lifecycle. ICH008 Compatible both to US/EU product wise lifecycle and to Japan applicationwise lifecycle. ICH009 ARCHIVE It must be possible to review and to archive the sequence without need for transformation ICH010 AUTHOR REVIEW It should be possible to review the ectd ICH011 AUTHOR REVIEW The specification should not restrict the types of file formats which can be submitted for use with the standard (allowed file formats are defined by each implementation and are not defined by the exchange specification). ICH012 AUTHOR REVIEW It should be possible for the reviewer to have access to the entire application from any part of the application. ICH013 AUTHOR REVIEW Clear definition of views across multiple sequences (cumulative, current) viewer/implementation requirement ICH014 BACKWARD COMPATIBLE Elements and attributes defined by V3.x should be able to be mapped to v4.0 constructs (and not the reverse) ICH016 BACKWARD The message should support continued use of the information and COMPATIBLE documentation provided with previous regional implementations, e.g., Module 1, STF. ICH017 DATASETS It should be possible to provide data definitions for data sets. ICH018 DOCUMENT It should be possible to support the inclusion of scanned documents, FORMATTING primarily for legacy documents ICH019 DOCUMENT METADATA It must be possible to describe, in free text, the titles of the files being submitted Title can be different per usage (e.g., context)

ICH020 ICH021 ICH024 ICH025 DOCUMENT METADATA DOCUMENT METADATA Every submitted file will have a unique identifier It must be possible for a Submitter to provide user defined information or identifier for a file DOCUMENT REUSE It must be possible to include by reference, a file that physically resides in the same or another sequence within the same regulatory activity, different regulatory activity within the same application or in a different application (e.g.. cross product submission support) DOCUMENT REUSE It must be possible to include, by reference, a file that has been submitted in a previous sequence and to be able to identify that this is not new but is being used in a different context For each file submitted by the Sponsor, a data field is present in the message for the Sponsor to include Sponsor-specified meta data (e.g., Sponsor internal version number or tracking information or OID). This requirement is currently provided by the version attribute in the ICH ectd v3.2.2 leaf element and should continue as an option in the ectd NMV. As this free text field refers to the actual content file, it should be an attribute of the file element in the message. It is proposed the field be called something like owners-version-number or senders-identifier (note wording to account for two way communication). This field would be optional. A file has been submitted to a dossier as part of an application's supportive documentation. The file is assigned a unique identifier in an ectd submission. The information contained in the file is later required to be available for use in the review of a supplement/additional application. The applicant wishes to include the previously submitted file in the supplement/additional application by referring to the file by its unique identifier rather than submitting the file for a second time. A reviewer viewing the supplement/additional application would view the file as though it was submitted to the supplement/additional application along with the other supportive documentation that was actually submitted. implementation Reviewer Capability ICH026 ENVELOPE It must be possible to assign an identifier to a sequence to imply an order, to enable sorting (e.g., chronology or review order) or just to assign uniqueness within an application [unique identifier for the sequence within the application and a friendly identifier] ICH027 ENVELOPE It must be possible to identify the regulatory agency for which a specific sequence is intended ICH028 ENVELOPE It must be possible to identify the applicant submitting a sequence ICH029 ENVELOPE It must be possible to unambiguously associate a sequence to the application(s) to which it belongs ICH030 ENVELOPE It must be possible to assign a submission type being used for the sequence ICH031 ENVELOPE It must be possible to describe, in free text, the sequence (include a short description of the sequence in the administrative section) ICH032 ENVELOPE It must be possible to identify the Procedure type being used for the application ICH033 ENVELOPE It must be possible to assign an invented name (trade name) for the product covered by the application ICH034 ENVELOPE It must be possible to assign an international non proprietory name(s) (inn) for the drug substance(s) covered by the application Not just EU Regional Not just EU Regional

ICH035 EU REGIONAL It must be possible to identify to which specific country a file is relevant ICH036 EU REGIONAL It must be possible to identify that a file is relevant to all countries ICH037 EU REGIONAL It must be possible to identify for which country(ies) a specific sequence is intended ICH038 HARMONISATION The message should support ICH harmonized content (documentation and metadata) and ICH regional content ICH039 HARMONISATION Need to provide a structure that supports all terminologies for dossier (all controlled vocabularies / Implementation Guide regulatory activity related to a product) and regulatory activity (collection of sequences that lead to a decision by the regulatory agency (NDS, SNDS)) which can be mapped to individual ICH regional regulatory processes ICH040 HARMONISATION Files should only need to be submitted once to a Health Authority and can Clarify meaning of application be included by reference in multiple sequences to support multiple regulatory actions even across applications ICH041 HARMONISATION Ability to reuse of ectd submitted in other regions. e.g. reuse of leaf files, Industry building tool need XML instance by module, ecsr. To achieve this, it is critical to distinguish global part and regional part even in Module2 5, not only in Module1. ICH042 HARMONISATION When the same documentation is provided, it should be submitted in the same way across HAs. For example, when a study report is submitted in US it is submitted using the STF which is not acceptable in other HAs. This minimizes reuse capabilities and adds to Industry costs to prepare globally harmonized dossiers. ICH043 HYPERLINKING It should be possible for the applicant to include hyperlinks between information ICH044 HYPERLINKING It should be possible to utilise relative addressing for all links. ICH046 HYPERLINKING Need to support relative links across the product lifecycle ICH047 ICH PROCEDURE For validation purposes, It should be able to uniquely identify: where in CTD a leaf belongs the relationship between leafs the lifecycle relationship (append, delete, or replace) between files the relationship between sequences the relationship of a sequence to a regulatory activity the relationship between applications the type of relationship (parent child, reference, etc) ICH048 JP REGIONAL Message should support the ability to provide second and subsequent sequences which contain only additional information in XML Instance Principle Implementation Guide

ICH049 LANGUAGE It must be possible to assign a language to a document ICH050 LANGUAGE It must be possible to (incorporate unicode character sets) to deal with languages such as Bulgarian and Greek ICH051 LANGUAGE It must be possible to include files with 1 or 2 byte characters, or a mixture of both ICH052 LANGUAGE ectd viewer should recognize section titles defined in CTD, e.g. "2.5 Clinical Overview". It should have an interface capable to show CTD section titles in any languages by switching standard dictionary provided by regional agencies. ICH053 The message should provide the ability to assign new metadata to update information previously submitted e.g., related sequences, submission type, operation attribute, manufacturer name, etc. ICH054 The message should provide the ability to unassign metadata previously submitted, e.g., related sequences, submission type, operation attribute, manufacturer name, etc. ICH055 The message should provide the ability to revise metadata previously submitted, e.g., related sequences, submission type, operation attribute, manufacturer name, etc. ICH056 Information provided in the message ( i.e., metadata) used to categorize documentation (e.g., attributes of drug substance, manufacturer, etc) or supplied in the regional envelope (e.g., Company Name, Sponsor) can be modified (i.e., added, edited, removed) during the life cycle of the application. ICH057 Replacement of multiple leafs with single leaf and vice versa should be supported in ectd. ICH058 The process for concatenating individual sequences into a combined sequence view (i.e., the current view and the cumulative view) must be unambiguously defined ICH059 ICH060 LOGICAL GROUPINGS LOGICAL GROUPINGS Provide ability to group a collection (or set) of files that together represent a document or reviewable grouping (e.g., all files related to a study report, all files related to a labeling document, all files related to a manufacturer or manufacturing component (e.g., container closure)) Provide ability to treat a grouping of files as a single entity and to be treated as if it were a single file (complete with all descriptive attributes e.g., title) for all life cycle operations and relationship management and reuse needs ICH061 PHYSICAL FILE RULES Filenames can include underscores Deal with greek and cyrillic viewer requirement / controlled vocabulary Delete examples viewer requirement / implementation ICH062 PHYSICAL FILE RULES It should be possible to constrain the contents to ensure there are no security settings, such as passwords. Implementation Guide

ICH063 PHYSICAL FILE RULES The physical file structure. (file/folder structure) should be minimal ICH064 PHYSICAL FILE RULES The technical message should not restrict the types of files that may be transferred. However, implementation guides may restrict the types of files and versions of file formats to be transferred or may specify unique file formats for that region. ICH065 PHYSICAL FILE RULES It should be possible to support file systems of different operating systems ICH066 PHYSICAL FILE RULES It must be possible to constrain the maximum size of any file (reword to Implementation issue reflect ICH minimum standard) ICH067 SCOPE Allow the capacity to modify the ICH CTD organizational structure (ToC) without modifying or changing the ectd message structure ICH068 SCOPE It should be possible to compile an ectd equivalent to the CTD ICH069 STANDARDS The message should interoperate with other healthcare standards, e.g. use controlled vocabularies from established standard based vocabularies ICH070 STANDARDS It should be possible to restrict the technology utilized to use open (ISO, Principle W3C, IETF) standards when ever possible. ICH071 STRUCTURE It must be possible to constrain the inclusion of documents at inappropriate locations in the submission structure (e.g.. at highest levels of ectd) ICH072 STRUCTURE The message should allow for the control/enforcement of document/structural granularity. ICH073 STRUCTURE It must be possible to assign 'attributes' to the contents of specific sections to support the ICH CTD organizational structure (e.g., repeating section 3.2.S) ICH074 STRUCTURE It must be possible to ensure that all files submitted are defined and referenced ICH075 STRUCTURE It must be possible to validate the contents of a sequence against the CTD (e.g., module 6 is invalid) ICH076 STRUCTURE It should be possible to identify all of the files relevant to a specific section of the CTD ICH077 STRUCTURE It should be possible to review the sequence in its entirety or in sections. Method of transmission should support the consumption ICH078 TECHNOLOGY The standard must not be constrained by the need for delivery via a particular medium ICH079 TECHNOLOGY It should be possible to include colour and black & white images ICH080 TECHNOLOGY It should be possible to support the introduction of new technology to aid in the review process. ICH081 TERMINOLOGY The message should support the use of controlled vocabularies for harmonized metadata ICH082 TERMINOLOGY The message should support the use of controlled vocabularies for regional metadata.

ICH083 TERMINOLOGY It should be possible to specify date values in an unambiguous manner. ICH084 TRANSFER/SECURITY The message should support a means to enable the validation of the integrity of the electronic files within an instance ICH085 TRANSFER/SECURITY The message standard should not restrict the mechanism for transmitting the message (e.g., media type, network) ICH086 TRANSFER/SECURITY The message standard should not restrict or prevent regionally implemented secure electronic message delivery standards ICH087 TWO WAY The message should support submission of a sequence from a regulator to COMMUNICATION a regulated party. ICH090 TWO WAY COMMUNICATION It should be possible to define the security methods to be used for transmission to the agencies and acknowledgement from the agency. ICH091 US REGIONAL The message should support the identification of the role of the instance within the identified regulatory activity, e.g. presubmision, application, amendment, etc. ICH092 US REGIONAL The message should support the identification of the regulatory activity associated with the instance, e.g. original application, labelingsupplement, etc. ICH093 VALIDATION It must be possible to define unambiguously, the validation criteria for a sequence ICH094 VALIDATION Message should contain sufficient information to unambiguously identify which version(s) of the DTD/Schema and controlling vocabularies was used to create the instance ICH095 VALIDATION The message should not require the submission of the DTD/Schema and controlling vocabularies with each instance ICH097 COMPATIBILITY It should be possible for an applicant to build on an ectd lifecycle started using the ectd 3.2.x specification and continued using the ectd NMV specification ICH098 COMPATIBILITY No applicant should be required to resubmit data in the ectd NMV specification if it has previously been submitted using the ectd 3.2.x specification. (It is recognised that in the future, further major versions of the ectd specification may require data migration guidance to ensure the use of data over the life of a drug product). Implementation GuIde Principle ICH099 COMPATIBILITY Tools designed to view ectd NMV sequences must also be able to view a lifecycle started with the ectd 3.2.x specification. However, the reverse requirement is not needed (i.e. it is not needed that tools for the ectd 3.2.x specification should be able to view sequences created using the ectd NMV specification). ICH100 COMPATIBILITY It is expected that once an ectd lifecycle is transitioned to the ectd NMV specification, then no further submissions/sequences will be made in the ectd 3.2.x specification.

ICH101 COMPATIBILITY The implementation guide must state how lifecycle relationships can be maintained from ectd 3.2.x to ectd NMV. ICH102 COMPATIBILITY Ability to reuse content; files submitted in ectd sequences can be referenced in ectd NMV submission units ICH104 DESIGN CONCEPTS The file format of the message should be xml based. ICH105 DESIGN CONCEPTS The message standard should not prevent or restrict the ability to e sign the message. ICH106 DESIGN CONCEPTS The message standard should not prevent or restrict the ability to encrypt the message for secure transfer purposes ICH107 DESIGN CONCEPTS The message standard must not require encryption ICH108 INTEGRITY Integrity checks for all files included in the sequence are required. ICH109 DESIGN CONCEPTS The message should provide the ability to identify further specific usage of the file (e.g., SPL, SDTM, application format, packaging insert, CTN) beyond that defined by the CTD ICH110 INTEGRITY The ability to specify which algorithm is being used for file integrity checks is required. ICH112 TWO WAY COMMUNICATION It must be possible to relate any message to a particular message, regulated activity and/or application. Every ectd message must be uniquely identifiable. ICH113 TWO WAY COMMUNICATION ICH114 DESIGN CONCEPTS In, the number of xml files managing content should be kept to a minimum and use a consistent technical design approach even though the content models may differ regionally ICH115 ENVELOPE The message standard must provide the ability to include information required for the processing (e.g., message standard version) and integrity (e.g., checksum) of the message ICH116 ENVELOPE The message standard must provide a three level hierarchy of application, regulatory activity and submission unit. ICH117 ENVELOPE The message standard must provide information about the product. enumerate data points to be required regionally ICH118 ENVELOPE The message standard must provide enough information to identify the sender. ICH119 ENVELOPE The message standard must provide enough information to identify the recipient. enumerate data points to be required regionally enumerate data points to be required regionally

ICH121 The order/sequence of leaf elements within a CTD section must be able to be controlled ICH122 A file can be displayed in multiple sections of the CTD (preserving the leaf file concept in the current ectd specification) ICH123 Maintain a similar file leaf model as in the current ectd in the ectd NMV, with the following exception/changes: a. The operation attribute value append be removed from the list of allowed values (leaving only new, replace and delete) b. Allow a replace or delete leaf to modify more than one leaf in a previous sequence or sequences c. Allow a single leaf to be modified by more than one leaf in later sequences (supports changes in granularity) ICH124 A file can be replaced in one existing ectd section or context without impacting the use of the file in other ectd sections or contexts ICH125 Life cycle operations must occur within the same context as the existing (target) leaf ICH126 There should be no restrictions on the characters used in controlled vocabularies ICH127 There should be a basic ICH stylesheet for presentation purposes ICH128 STF construct should be integrated into the message standard ICH129 Cardinality rules of the current ectd Specification should be retained plus those cited in approved Change Requests (e.g., CR#1490/1500 Module 3.2.A.3 will be made a repeating attribute in Version 3.2 of the specification based on excipient). ICH130 DESIGN CONCEPTS The message standard should allow the ability to e sign the message.