FMC-IO68 User Manual Document Revision: th October 2015

Similar documents
ADC-PCIE-XMC User Manual

ADC-PCIE-XMC3 User Manual

ADC-XMC-BREAKOUT User Manual

XRM-HSSDC2A. High Speed Serial Adaptor Module. User Guide. Version 1.1

ADM-XRC-5T*/6T* Cooling Solutions

ADC-XMC-II Revision: 1.0 Date: 17th June 2011

XRM-CLINK-ADV. Full/Medium/Base Camera Link and Dual ADV212 Adaptor. User Guide. Version 1.0

FMC-4SFP+ Pin Assignments. Dual- and Quad-channel SFP/SFP+ FMC Adapter FMC FPGA MEZZANINE CARD

XRM-FCN. High Speed Serial Adaptor Module. User Guide. Version 1.2

MC20902-EVB. MC20902 D-PHY 5-Channel Master Transmitter Evaluation Board User's Guide PRELIMINARY DATASHEET. Version February 2014.

ProtoFMC Safety Precautions Revision History

15-pin Nano-D Digital Interface

General Operating, Maintenance and Installation Manual

High Speed Serial Adaptor Module plus Dual JPEG 2000 CODEC

19. VITA 57.1 FMC HPC Connector

Installation Instructions

HDMI to FMC Module User Guide

ADM-PCIE-9H7 Support & Development Kit Release: 0.1.1

CHAPTER 3 Installation Conditions

ADM-PCIE-KU3 Support & Development Kit Release: 2.0.0

GT- IRDM-9603 Product description Rev. 2 17/06/2014

SFPFMC User Manual Rev May-14

SMT-FMC211. Quad DAC FMC. Sundance Multiprocessor Technology Limited

CPCI-HPDI32ALT High-speed 64 Bit Parallel Digital I/O PCI Board 100 to 400 Mbytes/s Cable I/O with PCI-DMA engine

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

SPMC/DPMC-214. CANbus, MilCAN, Utility Bus, and Discrete Digital I/O Module. --Based on dual ColdFire 5485 processors with dual FlexCan interfaces

VPX Test Platform User Manual

PMC494 10BaseT to 10Base2 PMC Media Converter

AQ_G24 GSM Terminal Card Motorola Cellular GSM Engine

PowerFlex DC Drive Frame B Pulse Transformer Circuit Board

ADM-XRC-5LX. PCI Mezzanine Card. User Guide. Version 2.0

ADM-XRC-7Z2 User Manual

Intel NUC Kit NUC8i7HNK & NUC8i7HVK User Guide. Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK User Guide

Addressable Bus Buffer Provides Capacitance Buffering, Live Insertion and Nested Addressing in 2-WireBus Systems

by Opal Kelly SYZYGY Specification Version 1.0

ACROMAG INCORPORATED Tel: (248) South Wixom Road Fax: (248) P.O. BOX 437 Wixom, MI U.S.A.

Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH

MEV Limited USB232/485 INSTRUCTION MANUAL

Version MICROSTRAIN, INC. Microminiature Sensors. OEM Inertia-Link /3DM-GX2 Modules. Guidelines for Use of OEM Inertia-Link /3DM-GX2 Modules

ASIX USB-to-LAN Applications Layout Guide

User s Guide. ASCII Interface RS-232 to I 2 C Host Adapter with Circuit Sense.

EZ864 UMTS Terminal Telit Cellular GSM Engine

XMC Products. High-Performance XMC FPGAs, XMC 10gB Ethernet, and XMC Carrier Cards. XMC FPGAs. FPGA Extension I/O Modules.

Controller PC Hard Drive

ACQ400-MTCA-RTM-2 Functional Specification. High Performance Simultaneous Data Acquisition

Reference Manual DOC. REV. 1.1 AUG 2016 VL-EPH-V6

Technical Manual SMART TRAC DM6420 Multi I/O Card

PMC-440 ProWare FPGA Module & ProWare Design Kit

05-023r0 SAS-1.1 Connector figures 23 December 2004

NI PXIe-1062Q Power Supply Shuttle

User Manual. for the. KT-PCIe-DVI KT-PCIe-DVI

DYNAMIC ENGINEERING 150 DuBois St. Suite 3, Santa Cruz Ca Fax Est

User s Guide. ivolt. I 2 C Bus/SMBus Voltage Level Translator. For 1.5 V to 5 V Applications.

Level Shifter. for. Hardware User s Manual.

Intel NUC Kit NUC6CAYS User Guide

CHAPTER 3 Installation Conditions

USB-to-I2C. Ultra Hardware User s Manual.

IP-Unidig-E Line Input/Output with LineSafe ESD Protection IndustryPack User s Manual

MC FPGA Bridge IC. for. MIPI D-PHY Systems and SLVS to LVDS Conversion DATASHEET. Version August Meticom GmbH

A.G.P. Pro Specification

FMC150 User Manual r1.9 FMC150. User Manual. Abaco Systems, USA. Support Portal

Intel NUC Kit NUC8i7HNK & NUC8i7HVK User Guide. Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK. User Guide

Kvaser PCIEcan User's Guide

NI PXI-1042 POWER SUPPLY SHUTTLE USER GUIDE

INSTALLATION GUIDE ADAPTEC SCSI CARD 29320LP

SOM i1 Single Core SOM (System-On-Module) Rev 1.5

FMC231. Key Features. Benefits. FMC Quad ADC 1 GSPS and Quad DAC 2.8 GSPS FMC231. Quad ADC o

PMC669, PMC676, & RM676 Dual Port GigE Controllers

RS-422/485 PCIe Card

Embedded Tech Trends 2014 Rodger H. Hosking Pentek, Inc. VPX for Rugged, Conduction-Cooled Software Radio Virtex-7 Applications

Technical Manual SMART TRAC PS Card

SMT166-FMC User Guide

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:

ACCESS/A TM AUDIO CONTROL SYSTEM MODEL: A740

Intel NUC Kit NUC7i3BNHX1 with Intel Optane Memory. Intel NUC Kit NUC7i5BNHX1 with Intel Optane Memory

Installing a Network Module

UM008 FMC204 User Manual r1.14 FMC204. User Manual. Abaco Systems, USA. Support Portal

PMC429-4/8/16/32 Hardware Manual

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any

FCC Information. RoHS This product is RoHS compliant. SJ/T The following contains information that relates to China.

GT- HE910-EUD. Product description Rev. 8 21/02/ Overview

Channel Switch CS. General Operating, Maintenance and Installation Manual

Getting started with X-NUCLEO-53L1A1 long distance ranging ToF sensor expansion board based on VL53L1X for STM32 Nucleo

Chapter 2 ICB Architecture Chapter 3 Board Components GPIO Interface RS-232 Interface RS-485 Interface...

SMARC 2.0 Carrier. SMARC 2.0 Carrier Users Guide CTIM Revision Date:

User Guide for NUC8i5BEK, NUC8i3BEK. Intel NUC Kit NUC8i5BEK Intel NUC Kit NUC8i3BEK. User Guide

User Guide. Intel NUC 8 Business, a Mini PC with Windows 10 NUC8i7HNKQC. Intel NUC 8 Enthusiast, a Mini PC with Windows 10 NUC8i7HVKVA

XGSF-T /100/1000 BASE-T Copper SFP Transceiver

DYNAMIC ENGINEERING 150 DuBois St. Suite C Santa Cruz CA Fax Est.

MC Channel FPGA Bridge IC. for. MIPI D-PHY Systems and SLVS to LVDS Conversion PRELIMINARY DATASHEET. Version August 2014.

TRBOnet Swift Agent A001

DYNAMIC ENGINEERING 150 DuBois St. Suite C Santa Cruz CA Fax Est.

DYNAMIC ENGINEERING 435 Park Dr., Ben Lomond, Calif Fax Est

DYNAMIC ENGINEERING 150 DuBois St. Suite 3, Santa Cruz, Calif Fax Est.

Functional Diagram: Serial Interface: Serial Signals:

EZL-200F Application Notes (003) Serial Interface (RS232/RS422/RS485)

PCI-SIO4B Quad Channel High Performance Serial I/O PCI CARD With up to 256Kbytes of FIFO buffering and Multiple Serial Protocols

Installation of the POTS splitter card requires the following steps: Determining the cables you need. Installing the POTS splitter chassis

Intel NUC Kit DN2820FYKH User Guide. Intel NUC Kit DN2820FYKH User Guide

Transcription:

FMC-IO68 User Manual Document Revision: 1.2 14th October 2015

2015 Copyright Alpha Data Parallel Systems Ltd. All rights reserved. This publication is protected by Copyright Law, with all rights reserved. No part of this publication may be reproduced, in any shape or form, without prior written consent from Alpha Data Parallel Systems Ltd. Head Office Address: 4 West Silvermills Lane, Edinburgh, EH3 5BD, UK Telephone: +44 131 558 2600 Fax: +44 131 558 2700 email: sales@alpha-data.com website: http://www.alpha-data.com US Office 3507 Ringsby Court Suite 105, Denver, CO 80216 (303) 954 8768 (866) 820 9956 toll free sales@alpha-data.com http://www.alpha-data.com All trademarks are the property of their respective owners.

Table Of Contents 1 Introduction... 1 1.1 References & Specifications... 1 2 User Input/Output Signals... 2 2.1 Level Shifting Options... 2 2.2 Ground Connections... 3 2.3 VHDCI SCSI Connector... 3 3 General Purpose IO... 4 3.1 Overview... 4 3.1.1 Direct Connections to the FPGA... 4 3.1.2 Serial Interface... 4 3.1.3 General Purpose IO... 4 3.2 Connectors... 4 3.3 Mating Cables... 4 4 Installation... 5 4.1 Handling instructions... 5 4.2 IO Voltage Selection... 5 5 Order Code... 5 Appendix A VHDCI Pin Assignments... 7 Appendix B Alpha Data GPIO Pin Assignments... 8 List of Tables Table 1 References... 1 Table 2 Order Code... 5 Table 3 VHDCI Pin Assignments... 7 Table 4 GPIO Locations... 8 List of Figures Figure 1 FMC-IO68 Image... 1 Figure 2 FMC-IO68 Block Diagram... 1 Figure 3 FMC-IO68 Top Side Features... 2 Figure 4 VHDCI Cable... 3

Page Intentionally left blank

1 Introduction The FMC-IO68 is a VITA 57.1 compliant single width HPC FMC module, designed for use with Alpha Data's VITA 57.1 compliant carrier cards. It provides the user with 68 IO signals to an industry standard SCSI connector. Figure 1 : FMC-IO68 Image Key Features FMC (VITA 57.1) compliant Conduction and air cooled compatible 68 single ended (34 differential) signals routed to VHDCI 68 position SCSI Operating temperature range from -45 to 85 degrees Celsius Level shifting and resistor fit options for application customization Up to 4x serial channels and 4x 3.3V GPIO on Alpha Data FMC GPIO 68 Pin SCSI 68 GPIO (Differential) LA EEPROM LVL Shift I2C FMC HPC Internal Plugable GPIO 6x U.FL 2x RS232/422 Links 4x 3.3V CMOS 6x Direct to FPGA (3x Differential Pairs) HB 1.1 References & Specifications Figure 2 : FMC-IO68 Block Diagram ANSI/VITA 57.1 FPGA Mezzanine Card (FMC) Standard, February 2010, VITA, ISBN 1-885731-49-3 Table 1 : References Introduction Page 1

J3 J4 VHDCI (J9) FMC (J1) J5 J6 J7 J8 Figure 3 : FMC-IO68 Top Side Features 2 User Input/Output Signals 2.1 Level Shifting Options Level Shifting Options The 68 signals from the FMC connector have three Level shifting options: 1 Direct Connect: This option fits resistor that tie the VHDCI pins directly to the FMC pins. This option supports both differential signaling standards (i.e. LVDS) and single ended (i.e. CMOS) directly to an FPGA. However the maximum supported IO voltage of the FPGA must be considered when using this option. 2 3V3: This option fits auto-direction sensing level shifters that are push-pull and open-drain compatible between the FMC and VHDCI connector. The IO level of the level shifters is 3.3V CMOS compatible. These level shifters do not support differential signaling. The FPGA IO bank can operate down to 1.2V with this option. 3 5V0: This option fits auto-direction sensing level shifters that are push-pull and open-drain compatible between the FMC and VHDCI connector. The IO level of the level shifters is 5.0V CMOS compatible. These level shifters do not support differential signaling. The FPGA IO bank can operate down to 1.2V with this option. Note: When using the level translators, be sure to carefully read the application note describing the operation of the circuit found here: http://www.ti.com/lit/an/scea044/scea044.pdf Note in particular the points about load capacitance and wire length. Note: The level shifters are 8 bits wide and can be fitted in a custom configuration to allow some direct connect and some buffered signals through the same VHDCI connector. Contact sales@alpha-data.com for more details. Page 2 User Input/Output Signals

2.2 Ground Connections Each signal has a resistor site that can be fitted to tie the signal directly to ground. This can be used to enhance signal integrity and provide a ground reference in the cable. Contact sales@alpha-data.com for more details. By default the case of the VHDCI connector is tied to Chassis Ground. The case can be tied to signal ground instead, contact sales@alpha-data.com for more details. 2.3 VHDCI SCSI Connector Receptacle The VHDCI SCSI connector on the FMC-IO68 is a widely used industry standard connector that provides screw lock retention. The part is available from multiple manufactures. Ultra+ VHDCI connector system: Molex part number 71430-0008 Figure 4 : VHDCI Cable User Input/Output Signals Page 3

3 General Purpose IO 3.1 Overview This FMC module provides the user access to a number of general purpose connectors that can be used for many different functions. The GPIO interface can be broken down into three components: 3.1.1 Direct Connections to the FPGA There are three differential pairs accessible through industry standard U.FL connectors. These pairs are ideal for clocking and synchronization. 3.1.2 Serial Interface Serial Transceiver Configurations The FMC hosts a Linear Technology LTC2872 configurable serial transceiver. This transceiver can be configured through strapping resistors to run in the following configurations: 4 channels of RS232 2 channels of RS232 and 1 channel of RS422 2 channels of 422 The default mode of operation is: 2 channels of 422. Please see the LTC2872 datasheet for more details on configurability. All 11 configuration signals are tied to strapping resistors and can be configured to your specific needs by contacting sales@alpha-data.com. 3.1.3 General Purpose IO Four signals from the FPGA are level translated to 3.3V and made available on the GPIO connector. The level translator is capable of driving both open-drain and push-pull signals. 3.2 Connectors Receptacles In order to guarantee the safety of the FPGA and enhance usability, this GPIO interface has been broken into multiple connectors. GPIO Connector: I-PEX part number 20455-020E-12 UFL Connector: Hirose part number U.FL-R-SMT-1(10) 3.3 Mating Cables Receptacles Below is a list of possible mating cables for each associated receptacle. GPIO Connector: Alpha Data adapter pigtail part number AD-FMC-GPIO UFL Connector: Industry standard U.FL cable (multiple vendors) Page 4 General Purpose IO

4 Installation The FMC-IO68 is designed to plug into the FMC front panel connector on a compatible carrier. The retaining screws should be tightened to secure the FMC. Note: This operation should not be performed while the host carrier is powered. 4.1 Handling instructions Observe precautions for preventing damage to components by electrostatic discharge. Personnel handling the board should take SSD precautions and avoid flexing the board. 4.2 IO Voltage Selection The required IO voltage range (VADJ) for the FMC is 1.2V to 3.3V. This is stored in a ROM on the FMC, as per VITA 57.1 for automatic configuration of supplies. The carrier is responsible for detecting and setting the IO voltage accordingly. 5 Order Code Product Code IO Voltage (v) FMC-IO68 (v) Blank = Direct Connect to FPGA /3V3 = 3.3V Bidirectional Buffer /5V0 = 5.0V Bidirectional Buffer Table 2 : Order Code Order Code Page 5

Page Intentionally left blank Page 6 Order Code

Appendix A: VHDCI Pin Assignments Signal FMC (J1) VHDCI (J9) VHDCI (J9) FMC (J1) Signal LA00_CC_P G6 1 35 G7 LA00_CC_N LA01_CC_P D8 2 36 D9 LA01_CC_N LA02_P H7 3 37 H8 LA02_N LA03_P G9 4 38 G10 LA03_N LA04_P H10 5 39 H11 LA04_N LA05_P D11 6 40 D12 LA05_N LA06_P C10 7 41 C11 LA06_N LA07_P H13 8 42 H14 LA07_N LA08_P G12 9 43 G13 LA08_N LA09_P D14 10 44 D15 LA09_N LA10_P C14 11 45 C15 LA10_N LA11_P H16 12 46 H17 LA11_N LA12_P G15 13 47 G16 LA12_N LA13_P D17 14 48 D18 LA13_N LA14_P C18 15 49 C19 LA14_N LA15_P H19 16 50 H20 LA15_N LA16_P G18 17 51 G19 LA16_N LA17_CC_P D20 18 52 D21 LA17_CC_N LA18_CC_P C22 19 53 C23 LA18_CC_N LA19_P H22 20 54 H23 LA19_N LA20_P G21 21 55 G22 LA20_N LA21_P H25 22 56 H26 LA21_N LA22_P G24 23 57 G25 LA22_N LA23_P D23 24 58 D24 LA23_N LA24_P H28 25 59 H29 LA24_N LA25_P G27 26 60 G28 LA25_N LA26_P D26 27 61 D27 LA26_N LA27_P C26 28 62 C27 LA27_N LA28_P H31 29 63 H32 LA28_N LA29_P G30 30 64 G31 LA29_N LA30_P H34 31 65 H35 LA30_N LA31_P G33 32 66 G34 LA31_N LA32_P H37 33 67 H38 LA32_N LA33_P G36 34 68 G37 LA33_N Table 3 : VHDCI Pin Assignments VHDCI Pin Assignments Page 7

Appendix B: Alpha Data GPIO Pin Assignments FMC-IO68 User Manual FMC Signal FMC (J1) Function (Connector) Function (Connector) FMC (J1) FMC Signal HB00_CC_P K25 UFL_0_P (J3) UFL_0_N (J4) K26 HB00CC N HB01_P J24 UFL_1_P (J5) UFL_1_N (J6) J25 HB01_N HB02_P F22 UFL_2_P (J7) UFL_2_N (J8) F23 HB02_N HB03_P E21 DY1 (Serial TX) RA1 (Serial RX) E22 HB03_N HB04_P F25 DY2 (Serial TX) RA2 (Serial RX) F26 HB04_N HB05_P E24 GPIO_0 GPIO_1 E25 HB05_N HB06_CC_P K28 - - K29 HB06_CC_N HB07_P J27 GPIO_2 GPIO_3 J28 HB07_N Table 4 : GPIO Locations Page 8 Alpha Data GPIO Pin Assignments

Revision History Date Revision Changed By Nature of Change 12 Nov 2013 1.0 K. Roth Initial Release 20 May 2014 1.1 L. Allison Added VHDCI Columns to Appendix Appendix A 14 Oct 2015 1.2 K. Roth Added note in Level Shifting Options pointing to the level translator application note. Alpha Data GPIO Pin Assignments Page 9

Page Intentionally left blank 4.5 Address: 4 West Silvermills Lane, Edinburgh, EH3 5BD, UK Telephone: +44 131 558 2600 Fax: +44 131 558 2700 email: sales@alpha-data.com website: http://www.alpha-data.com Address: 3507 Ringsby Court Suite 105, Denver, CO 80216 Telephone: (303) 954 8768 Fax: (866) 820 9956 toll free email: sales@alpha-data.com website: http://www.alpha-data.com