PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

Similar documents
PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

PSR UC/ESAM4/3X1/1X2/B

PSR DC/ESP4/2X1/1X2

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

PSR-PC20. SIL coupling relay. Data sheet. 1 Description

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

PSR-PS21. SIL coupling relay. Data sheet. 1 Description

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

Safety module - PSR-SCP- 24DC/TS/S

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

PHOENIX CONTACT - 05/2007

PLC-R 21HC. PLC INTERFACE With SPDT Relay, High-Current Version. INTERFACE Data Sheet _03_en. Description

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

ETD-BL-1T-OFF-CC- 10S

MINI MCR-SL-UI-2I(-SP)(-NC)

MINI-PS AC/10-15DC/8

PHOENIX CONTACT - 07/2006

PHOENIX CONTACT Features

MINI MCR-SL-PT100-UI(-SP)(-NC)

IB IL 24/48 DOR 2/W-XC-PAC

MINI MCR-SL-CVS NC

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

PI-EX-ME-2NAM/COC-120VAC

PI-EX-ME-2NAM/COC-24VDC

MINI MCR-SL-UI-REL(-SP)

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

PHOENIX CONTACT - 10/2009

QUINT-PS-3x AC/24DC/10

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

MINI MCR-SL-PT100-UI-200

Redundancy Module QUINT-DIODE/40

PHOENIX CONTACT - 01/2007

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

PHOENIX CONTACT - 12/2007

onlinecomponents.com

PLC-RSC- 24UC/21. Extract from the online catalog. Order No.:

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

MACX MCR-EX-SD LP(-SP)

MINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.:

PSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1.

DEK-REL- 5/I/1. Extract from the online catalog. Order No.:

PLC-RSC- 24DC/21 Order No.:

Extract from the online catalog

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

MACX MCR-EX-SL-NAM-R(-SP)

Power Supply, Primary Switch Mode for Universal Use QUINT-PS AC/48DC/5

PLC-RSC- 24DC/21. Extract from the online catalog. Order No.:

TRIO-DIODE/12-24DC/2X10/1X20

MACX MCR-EX-SL-NAM-2RO(-SP)

EMD-SL-LL-230. Electronic monitoring relay for level monitoring of conductive liquids. INTERFACE Data sheet _en_04. 1 Description.

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

PSI-MODEM-SHDSL/SERIAL

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

Operating instructions. Speed monitor D / / 2014

Operating instructions. Switching amplifier DN0210 DN / / 2015

PLC-RSC- 24DC/ Extract from the online catalog. Order No.:

This data sheet is only valid in association with the IL SYS INST UM E user manual.

IB IL 120 DI 1. Function. INTERBUS Inline Terminal With One Digital Input in the 120 V AC Voltage Area. Data Sheet 5764B

PHOENIX CONTACT - 01/2008

Original operating instructions Safety relay with relay outputs G1501S / / 2016

ASI QUINT /2.4 EFD

INTERFACE. User Manual

ITEM ESM-BA301

ELR H3-IES-PT- 24DC/500AC-...

QUINT-BUFFER/24DC/24DC/40

PLC-OSC-120UC/ 24DC/ 2

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Safety relay emergency stop/protective door, 24V-230VDC/AC, 3 enabling paths

STEP-PS/1AC/24DC/1.75

REL-MR- 12DC/ Extract from the online catalog. Order No.: Pluggable miniature relays, with power contact, 2 PDT, input voltage 12 V DC

RAD-DAIO6-IFS. I/O extension module, 1 analog input/output, 2 digital wide-range inputs/outputs. INTERFACE Data sheet.

FL MC 2000E (SM40) LC

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

SUNCLIX Connection technology for photovoltaics

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

DEK-OV- 5DC/ 24DC/ 3. Extract from the online catalog. Order No.:

Extract from the online catalog

Safety relay emergency stop/protective door, 24VDC/AC, 3 enabling paths

SECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i

TT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.:

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

QUINT-PS/ 1AC/24DC/ 5

Contact protection relay

Extract from the online catalog

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

VAL-CP-1S-175. Extract from the online catalog. Order No.:

VAL-CP-3S-350. Extract from the online catalog. Order No.:

Transcription:

Safety Relay as a Contact Extension Block INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- 24DC/URM4/4X1/2X2/B safety relay can be used as a contact extension block in safety circuits according to DIN EN 60204-1/VDE 03-1. The device has an interface for the T-BUS DIN rail connector. This interface can be used for single-channel control and monitoring. Alternatively, the device can also be operated in single-channel mode via a contact on the basic device. Depending on the external wiring, the maximum safety category that can be achieved is safety category 4 according to EN 954-1. The relay has four enable current paths, one signaling current path, and one confirmation path. The contacts drop without delay according to stop category 0 (DIN EN 60204-1/VDE 03-1). The extension unit can be used as a contact multiplier for emergency stop relays and two-hand controls. Observe the safety instructions on page 4. Make sure you always use the latest documentation. It can be downloaded at www.download.phoenixcontact.com. A conversion table is available on the Internet at http://www.download.phoenixcontact.com/general/7000_en_00.pdf. This data sheet is valid for all products listed on the following page: 102856_01_en PHOENIX CONTACT GmbH & Co. KG 32823 Blomberg Germany 1 Phone: +49-52 35-30 0 Fax: +49-52 35-34 00 www.phoenixcontact.com www.phoenixcontact.com/salesnetwork

Ordering Data Safety Relays Description Type Order No. Pcs./Pkt. Safety relay as a contact extension block, with screw connection 2981677 1 Safety relay as a contact extension block, with spring-cage connection 2981680 1 Accessories Description Type Order No. Pcs./Pkt. DIN rail connector, yellow, for PSR applications PSR-TBUS 2890425 50 Dummy plug PSR-TBUS-TP 2981716 50 Documentation Description Type Order No. Pcs./Pkt. Application manual for PSR safety relays UM EN SAFETY RELAY APPLICATION 28887 1 Technical Data Input Data Nominal input voltage U N Permissible range Typical current consumption at U N Typical response time (, ) Typical release time (, ) Surge protection Status indicators (, ) 24 V DC 0.85-1.1 x U N 100 ma 10 ms 10 ms Suppressor diode Green LED Output Data Contact type: Positively driven contact assembly Class A according to EN 50205 Contact material Silver tin oxide (AgSnO 2 ) Maximum switching voltage 250 V AC/DC Minimum switching voltage 15 V AC/DC Limiting continuous current N/O contact N/C contact Maximum inrush current N/O contact N/C contact Minimum switching current Maximum shutdown power 1 Minimum switching power Mechanical service life 4 enable current paths, 1 signaling current path, 1 confirmation path 6 A 3 A 6 A 3 A 25 ma Ohmic load τ = 0 ms 24 V DC 144 W (72 W) 1 48 V DC 288 W (144 W) 1 0 V DC 77 W 220 V DC 88 W 250 V AC 1500 VA (750 VA) 1 0.4 W 10 7 cycles, approximately Inductive load τ = 40 ms 48 W 40 W 35 W 33 W 102856_01_en PHOENIX CONTACT 2

Output Data (Continued) Switching capacity according to DIN EN 60947-5-1/VDE 0660-200 Cycles DC13 AC15 360/h: 24 V: 6 A 230 V: 5 A Short-circuit protection of the output circuits, external Enable current paths Signaling current path 3600/h: 24 V: 3 A 230 V: 3 A NEOZED 10 A gl/gg NEOZED 4 A gl/gg 1 The maximum values given in brackets apply to N/C contacts 61-62. General Data Permissible ambient operating temperature -20 C to +55 C Nominal operating mode 100% operating factor Degree of protection according to VDE 0470-1 Housing IP20 Connection terminal blocks IP20 Installation location IP54, minimum Mounting position Any Air and creepage distances between circuits Basic insulation According to DIN EN 50178:1998-04 1 Impulse voltage withstand level 4 kv 1 Pollution degree 2 Surge voltage category III Dimensions (W x H x D) 22.5 mm x 99 mm x 4.5 mm 22.5 mm x 2 mm x 4.5 mm Conductor cross section 0.2 mm 2... 2.5 mm 2 0.2 mm 2... 1.5 mm 2 Housing material Polyamide PA, not reinforced 1 Safe isolation, reinforced insulation, and 6 kv between the input circuit/n/c contacts and the enable contact current paths. Tests/Approvals BG/GS UL applied for 102856_01_en PHOENIX CONTACT 3

Safety Instructions During operation, parts of electrical switching devices carry hazardous voltages. Before working on the device, disconnect the power. Please observe the safety regulations of electrical engineering and industrial safety and liability associations. Disregarding these safety regulations may result in death, serious personal injury or damage to equipment. Startup, assembly, modifications, and upgrades may only be carried out by a skilled electrical engineer. For emergency stop applications, the machine must be prevented from restarting automatically by a higher-level control system. Protective covers must not be removed when operating electrical switching devices. In the event of an error, replace the device immediately. Repairs, especially if the housing must be opened, may only be carried out by the manufacturer or authorized persons. Otherwise the warranty is invalidated. When operating relay modules the operator must meet the requirements for noise emission for electrical and electronic equipment (EN 61000-6-4) on the contact side and, if required, take appropriate measures. 102856_01_en PHOENIX CONTACT 4

54 PSR-...- 24DC/URM4/4X1/2X2/B Structure 4 2 5 6 7 9 4 8 6 7 8 9 4 43 44 Y1 / 23 A1 A2 61 62 24 33 34 0 5 4 3 43 44 Y1 / 23 A1 A2 61 62 24 33 34 A1 A2 61 62 23 24 33 34 0 / Y1 43 44 54 Y1 43 44 54 23 24 54 Order No.: 29 81 68 0 APPROVAL Serial No. 23 33 43 61 24 34 44 54 62 Order No.: 29 81 67 7 APPROVAL Serial No. 23 33 43 61 24 34 44 54 62 1 1 Figure 1 Structure 1 Metal lock for mounting on the DIN rail 2 Plug-in COMBICON screw terminal blocks 3 Plug-in COMBICON spring-cage terminal blocks 4 23-24, 33-34, 43-44, and -54: Enable current paths 5, : 24 V DC input 6 Y1: Connection to the DIN rail connector 7 -: Confirmation contacts 8 A1: Connection to the DIN rail connector 9 A2: Ground connection 10 61-62: Alarm contacts Block Diagram Y1 / A1 A2 23 24 33 34 43 44 54 61 62 Figure 2 Block diagram 102856_01_en PHOENIX CONTACT 5

Function When a 24 V DC voltage is applied at input - (or via the DIN rail connector), both relays are activated. The LED lights up and the contacts for enable current paths 23-24, 33-34, 43-44, and -54 close. Alarm contacts - and 61-62 open. If the voltage is switched off at input -, the enable contacts open and the alarm contacts close. For additional connection examples, see page 7. Connection Notes For PSR applications, only yellow PSR-TBUS connectors (Order No. 2890425) may be used. Connection with another T-BUS is not permitted. Devices may only be mounted on/removed from the T-BUS when the power is switched off. A T-BUS unit can contain a basic device (PSR-...-SDC...) and a maximum of 10 extension units (PSR-UR...). Extension units must be mounted to the right of the basic device. The feedback circuit must be closed at the last extension unit (on the right): jumper at Y1 and or PSR-TBUS-TP dummy plug (Order No. 2981716). The voltage supply can be provided at any PSR device or using a system power supply via the T-BUS. When using T-BUS DIN rail connectors, connect together the required number of T-BUS connectors and push them onto the DIN rail. When attaching the safety relay to the DIN rail, ensure that it is aligned correctly with the T-BUS connector (see Figure 3). ) PSR-TBUS D * + 3 Figure 3 Using the T-BUS DIN rail connector 102856_01_en PHOENIX CONTACT 6

54 54 PSR-...- 24DC/URM4/4X1/2X2/B In order to comply with UL approval, use copper cables that are designed for operating temperatures > 75 C. For reliable and safe-to-touch contacts, strip the cable ends as follows: 7mm 44 8mm 44 / Y1 Y1 43 44 43 44 54 54 23 24 Figure 4 Figure 5 Connection Examples Single-channel connection with confirmation path - integrated in the basic device, suitable for up to safety category 4 Reset S33S3413 23 31 A1 / 23 33 43 61 A1 A1 A1 / 23 33 43 61 A1 A2 A2 A2 PSR-SDC... / / / S33 Y1 Y1 A2 Y1 24 34 44 54 62 Y1 PSR-TBUS-TP 2981716 14 24 32 A2 Y1 24 34 44 54 62 Figure 7 Wiring via T-BUS DIN rail connector 24V DC GND Figure 6 Wiring via connection terminal blocks PHOENIX CONTACT 05/2006 102856_01_en PHOENIX CONTACT 7