Automation stations compact model

Similar documents
PXR11 PXR12. System controllers DESIGO PX

Automation station, compact series

Automation station, compact series

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

Room unit with PPS2 interface

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

Non-communicating room controllers

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

Automation stations, compact model

Automation stations modular series

Automation stations, compact model

Non-communicating room controllers

Room unit with PPS2 interface

RXL21.1 RXL22.1. Room controllers RXL. Communicating controllers for fan-coil applications FC-10, FC-11, FC12

Extension module for lighting control

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

Room automation station

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

Room unit with PPS2 interface

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

Room unit with PPS2 interface

Digital input modules

Room controller. For chilled ceiling and radiator applications CC-02 with Konnex bus communications (S-mode and LTE mode)

BACnet/IP Web Interface

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Web interface BACnet/IP

Universal Controller

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

EY-EM : Remote I/O module, ecolink

Extension module for BACnet over Ethernet / IP and graphic Web functions

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

Automation stations modular series

Super universal modules

~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Power supply module, bus connection module

Controller module. Brief description. Features. Block structure. Page 1/7. Data Sheet

IQ21x Series Controllers

RMZ792. Bus Operator Unit. Building Technologies HVAC Products. Synco 700

Temperature Controller

MXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems.

Air damper actuators

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Extension module for graphic Web functions for one automation station

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

Extension module for Web functions generic

Rotary version, three-position control

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix

PXM20-E. Operator unit BACnet auf Ethernet/IP DESIGO PX

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

SIMOCODE 3UF Motor Management and Control Devices

Island bus expansion module

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Temperature controller Ducted systems

BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

Immersion Temperature Sensors

Resistance measuring module

Controller module. Brief description. Features. Block structure. Data Sheet Page 1/7

Electrical Actuators

Room automation stations

Functional data Nominal torque min. 180 in lb [20 NM] Communicative control Cloud: (call for clientapi )

Climatix programmable controller

EXOcompact. Third generation freely programmable controllers

TALON Network Manager- 2 & 6 Express

Electrical Actuators

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

is then retained absolutely without interruption.

VAV compact controller KNX / PL-Link

TXM1.8RB. TX-I/O Blinds module

Extension module Integration of existing PTM I/O modules in Desigo Used with PXC50...D, PXC100...D or PXC200...D

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

Functional data Position indication reflective visual indicator (snap on) Communicative control Cloud: (call for clientapi )

I/O module, universal, digital, S0 inputs, modu533

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket

IMIO100 IMIO105. DDC controllers. Summary

EY-IO 534: I/O module, analogue inputs with galvanic isolation, modu534

I/O module, digital and universal inputs, modu530

VAV compact controller GDB181.1E/3 GLB181.1E/3

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

DS BAS /99 UNC 596 BUILDING AUTOMATION SYSTEM UNIVERSAL NETWORK CONTROLLER FEATURES

Heating Controllers. Siemens Building Technologies HVAC Products. Synco 700

POL635.XX/XXX POL636.XX/XXX POL638.XX/XXX POL638.70/XXX

Technical Information Fieldgate SFG500

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

MINI-PS AC/10-15DC/8

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

Climatix TM Climatix Controller. For controlling, switching and monitoring functions

Transcription:

9 PXC36-S DESIO PX Automation stations compact model PXC5 PXC36-S PXC5 Freely programmable compact automation stations for HVAC and building services systems The fixed data point mix ensures optimum efficiency for frequently used applications with standard signals Fixed data point mix for 36 or 5 physical data points per station Direct connection of field devices anagement functions (alarm management, time schedulers, trend functions, remote management, access protection, etc) Stand-alone application or use as interconnected devices/systems Optional devices variants (automation station with modem interfaces, manual switches) Connection of PX0 and PX0 operator units Connection of QAX room units Standard communication BACnet over LO BTL label (BACnet communications passed the BTL test) CA9en_0 009006 Building Technologies Building Automation

Functions Programming language These freely programmable automation stations provide the infrastructure for the provision and processing of system-specific and application-specific functions Apart from the freely programmable control functions these units comprise integrated convenient management functions such as: Alarm management with alarm routing throughout the whole network Three level alarm management (simple, basic and enhanced) with safety control transmission and automatic transmission monitoring Time schedulers Trend functions Remote management functions Access protection for the whole network with individually defined user profiles and categories Automation stations are freely programmable with the D-AP programming language (follows closely CE Standard 3) All function blocks available in libraries are graphically linked with the plant operating programs Communication The devices communicate via an open bus system in accordance with the international standard BACnet protocol Integrated peer-to-peer communication with other automation stations and also with PX0 and PX0 operator units Types Device Type Data point mix UI DI AO DO Automation station for 36 physical data points PXC36-S 6 6 Automation station for 5 physical data points PXC5 6 6 8 Compatibility Operator unit The automation stations are operated with the convenient PX0 and PX0 operator units with control buttons as well as displays in graph form and clear text The PX0 unit can be used either locally of decentralized for all plant connected together in one network, the PX0 only locally Room units A maximum of five room units QAX (not QAX5 ) can be operated via the PPS bus connection Details on the PPS communication are described in the DESIO Technical principles manual (chapter "I/O blocks", section "PPS addressing") Web operation The PX80-W Web controller provides remotely monitoring and operating one or several DESIO PX automation station(s) from a standard Internet browser The PX80-W Web controller is equipped with an additional Ethernet connection /4 Building Technologies PXC36-S, PXC5 Compact automation stations CA9en_0 Building Automation 009006

Technology Inputs Outputs The universal inputs (UI) accept passive and active sensor elements as well as voltfree contacts for signal functions Passive L-i 000, Pt 000, T Active 0 0 V Binary Volt-free (DC V) The purely binary inputs (DI) enable signal and counter functions Binary Volt-free (DC 4 V) Counters Volt-free up to 0 Hz (DC 4 V) only on D D4 On the one hand, universal outputs (AO) can control modulating actuators and, on the other hand, can be programmed via the program structure for binary switching functions Analogue 0 0 V Binary 0 or DC 0 4 V, max ma The relay outputs (DO) are designed for max AC 50 V, A anual switches (PXC36-S) The automation station PXC36-S has four manual switches (S S4) whose function can be adapted to various plant-specific requirements The manual switches S S4 can be operated either in the mode "Direct control" or "Software control" S and S can be optionally used as single-stage or two-stage switches S controls relays 5 and 5; S controls relays 53 and 54: Single stage (DIL 5 / 6 = O) Two-stage (DIL 5 / 6 = OFF) Stage (relays 5 / 53) Direct control O / OFF enabled Stage (relays 5 / 54) Direct control OFF enabled, O disabled Stage (relays 5 / 53) Direct control O / OFF enabled Stage (relays 5 / 54) Direct control O / OFF enabled S3 and S4 are one-stage switches Direct control O / OFF enabled (relays 55 and 56) Switches S4 S3 S S LEDs S Stage S Stage S Stage S Stage S3 Stage S4 Stage RU STATUS SERVICE TX IFO AUTO 0 AUTO 0 AUTO 0 --- AUTO 0 --- max AC 50V, 5A RES, A EPurpose Q Q4 Q Q Q4 Q Q3 Q34 Q3 Q4 Q44 Q4 Q5 Q54 Q5 Q6 Q64 Q6 5 5 53 54 55 56 0045 anual switches from left to right: S: Automatic/Off/Stage and S: Automatic/Off/Stage and S3: Automatic/Off/On S4: Automatic/Off/On anual switch allocation to relays 5 56: S: 5 / 5 (singlestage/two-stage) S: 5 / 5 (singlestage/two-stage) S3: 55 (single stage) S4: 56 (single stage) LED display for relay function The relay function in the switch positions Automatic and anual is indicated for each stage by a green LED Software control enables each LED to be programmed via a fault input (binary input) so that the display color changes to red (independent of the relay switch status) Building Technologies PXC36-S, PXC5 Compact automation stations CA9en_0 Building Automation 009006 3/4

DIL switches DIL switches are mounted at the back of the front cover: 0883 Printed circuit board O 3456 O OFF Front cover ode: Direct control / Software control DIL (S) DIL (S) DIL 3 (S3) DIL 4 (S4) OFF Direct control ) O Software control ) Single stage two-stage (manual switches S and S): OFF O DIL 5 (S) DIL 6 (S) Two-stage Single stage ) Direct control ) Software control Automatic: The relevant relay outputs are controlled via the plant operating program 0: The relevant relay outputs are switched off independent of the plant operating program / : The relevant relay outputs are switched on independent of the plant operating program It is also possible to use the manual switches S S4 as pure software switches Application specific functions can then be programmed In this configuration the relays are not controlled directly by the switches (Direct control is disabled) ote In software control mode the information on the positions of the manual switches S S4 is available on software level (but not the position of the DIL switches 6) In direct control mode the attempt to read will result in an error message (reliability) 4/4 Building Technologies PXC36-S, PXC5 Compact automation stations CA9en_0 Building Automation 009006

Design The compact construction enables the automation stations to be used in highly confined spaces and makes them especially suitable for compact control panels or buildings services systems with integrated control panels 5 0039 b 6 3 4 7 etal housing Front cover (hinged) 3 LED indicators 4 Printed circuit board 5 Plug-in screw terminal block 6 Upper terminals for operating voltage, bus system and input peripherals 7 Lower terminals for output peripherals LED indicators RU STATUS SERVICE TX IFO 0044 LED Color Activity Function RU reen Continuously off Continuously on o supply Supply OK STATUS Red Continuously off Continuously on Quick flashes ormal operation Hardware fault detected during self-test or automation station in "coma" operating state o validly licensed firmware SERVICE Red Continuously off Flashing Flashing acc to wink command pattern * Continuously on LO node is configured LO node is not configured Physical identification of automation station after receiving wink command LO chip defect or service key was pressed again TX Yellow Flashing Data traffic on LO bus IFO Red Freely programmable * Wink command rhythm pattern: s 00408 5 Hz 5 Hz s s s s Disposal The unit contains electric and electronic components and must not be disposed of with domestic waste Lithium battery, printed circuit board and housing must be disposed of separately The local and actual regulations must be observed 5/4 Building Technologies PXC36-S, PXC5 Compact automation stations CA9en_0 Building Automation 009006

ounting instructions The automation stations can be snap-mounted on DI rails or directly screwed to a mounting plate The connections for field devices, power supply and bus wiring are via plug-in screw terminals Commissioning In order to prevent equipment damage and/or personal injuries always follow local safety regulations and the required safety standards Loading plant operating program Setting parameters and configurations Wiring test Download the plant operating program to the automation station with the PX Design tool in the DESIO TOOLSET, direct via the RJ45 connector or the LO bus Convenient tools are available for commissioning Use the PX Design tool in the DESIO TOOLSET for setting the control parameters and the configuration data Data visible in the network can also be changed with a PX0 or PX0 operator unit It is possible to test field devices and the wiring as soon as the power supply is connected, without first downloading the plant operating program The test is carried out with a PX0 operator unit etwork connection 4 3 The network addresses are configured with the DESIO TOOLSET In order to provide a unique identification in the LO network press the service pin on the printed circuit board or send a wink command to the relevant automation station (service LED flashes) PXC36-S, PXC5 PXC5 (from 007) 9z0 3 4 9z Lithium battery AA alkaline battery Service pin Force Firmware Download key Force Firmware Download key: If this key is pressed during a restart (Power fail) the current D-AP program is deleted from the FLASH The automation station waits a short while for the signal to activate the FWLoader and then starts the automation station aintenance Battery life 6/4 Lithium batteries usually have a life span of at least four years The automation station automatically sends a system event in order to indicate a low charge After the "Battery low" event there are several months of remaining life span In the PXC5 from 007, the database information stored in the SDRA memory is battery-backed (Alkaline AA Type) This eliminates the need for time-consuming program and database re-entry in the event of an extended power failure (up to month) After the "Battery low" event there are several days of remaining life span under load Alkaline batteries have a typical life span of 4 years without load Building Technologies PXC36-S, PXC5 Compact automation stations CA9en_0 Building Automation 009006

When one of the batteries needs to be replaced, the automation station automatically sends a system event an alarm message can also be sent to selected terminals Battery change To change the battery remove the front cover As long as there is an external power supply, the battery may be removed for unlimited time STOP Caution! To prevent hardware damage by electrostatic discharge (ESD), a wrist strap with earth cable must be used during the battery change Technical data eneral device data Operating voltage ± 0 % Protective extra-low voltage PELV HD 384 Frequency 50/60 Hz Power consumption PXC36-S max 0 VA (depending on device type): PXC5 max 6 VA Internal fuse Thermic, automatic reset Operating data PXC36-S PXC5 Processor 68000 PPC (PC 885) emory space FLASH Up to 3 Bytes 6 B RA Up to 5 Bytes 64 B Data backup in case of power failure Applications, parameter (FLASH) > 0 years > 0 years Run-time data (battery) > 0 years > 0 years Run-time data (AA batt, PXC5 from 007) > month typical Real Time Clock (battery) > 0 years > 0 years Accuracy class 0,5 Scan cycle max s Universal inputs X Configurable by software easured value inputs Range 0 0 V Input resistance 00 kω against Sensor inputs Temperature sensors L-i 000, Pt 000, T Scaling range 50 50 C Sensor current (continuous current) Approx 5 ma Resolution 0 K easuring error at 5 C (i 000, PT 000) max 0 K (without cable and sensor) easuring error at 5 C (T) max 0 K (without cable and sensor) Signal inputs Contact voltage DC 0 5 V Contact current 7 ma Contact transfer resistance ax 00 Ω (closed) Contact isolation resistance in 50 kω (open) Binary inputs D * Contact voltage DC 0 5 V Contact current 7 ma Contact transfer resistance ax 00 Ω (closed) Contact isolation resistance in 50 kω (open) Universal outputs Y Configurable by software Proportional outputs Output voltage range 0 0 V Output current ax 4 ma source, max 5 ma sink Binary outputs (for off-board relays) Output voltage range 0/DC 0 4 V Load 000 Ω Building Technologies PXC36-S, PXC5 Compact automation stations CA9en_0 Building Automation 009006 7/4

Relay outputs Q ** Relay type single pole, change-over contact Contact details for AC voltage Voltage range in AC 0 V, max AC 50 V Current, resistive load ax AC 5 A Current, inductive load A Switching current in 0 ma, max 0 A Contact details for DC voltage Voltage range in DC 5 V, max DC 50 V Switching current in 00 ma at DC 5 V Switching load ax 0 W Interface, room units Interface type PPS Supply class 4 PPS baud rate 48 kbit/s LOWORKS bus interface etwork TP/FT-0 Transceiver FTT Baud rate 78 kbit/s Plug-in screw terminal Power supply and signals Stranded of solid conductors, 05 5 mm or x 5 mm LOWORKS bus Stranded or solid conductors, x 0 mm Single cable lengths Universal inputs X ax 00m where A = mm Binary inputs D ax 00 m with diameters 06 mm Universal outputs Y ax 00m where A 5 mm Relay outputs Q Depends on load and local regulations Interface, room unit ax 5 m where A = 0 mm Cable type -core, twisted pair, unscreened Capacitance per unit length ax 56 nf/km LOWORKS bus ax 450 m in free topology ax 900 m in serial topology Cable type -core, twisted pair, unscreened Connecting cable PX0 or PX0 / DESIO TOOLSET ax 3 m Housing protection standard Protection standard to E 6059 IP 0 Protection class Isolation protection class II Ambient conditions Operation Class 3K5 to IEC 7 Temperature 0 50 C Humidity < 85 % rh Transport Class K3 to IEC 7 Temperature 5 65 C Humidity < 95 % rh Industry standards Product safety Automatic electronic controls for household and similar use E 60730- Special requirements for energy controllers E 60730-- Electromagnetic compatibility Interference immunity E 5008- Emitted interference E 5008- eets requirements for CE marking: Electromagnetic compatibility 89/336/EEC Low Voltage Directive 73/3/EEC Dimensions See Dimensions Weight Type without packaging with packaging PXC36-S 480 kg 560 kg PXC5 80 kg 90 kg * The signal inputs D, D, D3, D4 are countable (max 0 Hz) ** The relay outputs are safely isolated from each other, from earth/cover and the remaining electronics () in accordance with SELV and PELV specifications The relay outputs can be used in mixing applications with AC 50 V and SELV/PELV circuits! 8/4 Building Technologies PXC36-S, PXC5 Compact automation stations CA9en_0 Building Automation 009006

Connection terminals PXC36-S TE 0 3 4 HI TOOL CLA CLB LOWORKS CP CP + X 6 X X3 X4 X5 7 X6 X7 X8 X9 8 X0 X X D D 9 D D3 D D4 9A03 QAX 0 Q Q4 Q Q Q4 Q Q3 Q34 Q3 Q4 Q44 Q4 Q5 Q54 Q5 Q6 Q64 Q6 Y Y Y3 Y4 D5 D D6 D7 D D8 D9 D D0 D D D max AC 50 V, 5A RES/ A P/ FLA / LRA Y5 Y6 5 5 53 54 55 56 70 7 7 TE Functional earth /0 Supply voltage HI / TOOL RJ45 socket (for PX0 or PX0 operator unit or DESIO TOOLSET) 3 CLA/CLB LO bus 4 CP+/CP- PPS bus (for QAX room units) 6 8 X X universal inputs 9 D D4 4 binary inputs (counters possible) 0 D5 D 8 binary inputs 5 56 Q Q6 6 relay outputs 70 7 Y Y6 6 universal outputs STOP Caution! Observe the technical data for the relay outputs Local installation regulations must be observed 9/4 Building Technologies PXC36-S, PXC5 Compact automation stations CA9en_0 Building Automation 009006

PXC5 TE 0 3 4 HI TOOL CLA CLB LonWorks CP CP + X 6 X X3 X4 X5 7 X6 X7 X8 X9 8 X0 X X D D 9 D D3 D D4 D5 D 0 D6 D7 D D8 9A04 QAX 3 max AC 50 V, 5A RES/ A P/ FLA / LRA Q Q4 Q Q Q4 Q Q3 Q34 Q3 Q4 Q44 Q4 Q5 Q54 Q5 Q6 Q64 Q6 Q7 Q74 Q7 Q8 Q84 Q8 Q9 Q94 Q9 Q0 Q04 Q0 Q Q4 Q Q Q4 Q Y Y Y3 Y4 Y5 Y6 Y7 Y8 X3 X4 X5 X6 D9 D D0 D D D D3 D D4 D5 D D6 5 5 53 54 55 56 57 58 59 60 6 6 70 7 7 73 TE Functional earth /0 Supply voltage HI / TOOL RJ45 socket (for PX0 or PX0 operator unit or DESIO TOOLSET) 3 CLA/CLB LO bus 4 CP+/CP- PPS bus (for QAX room units) 6 8 X X6 6 universal inputs 9 D D4 4 binary inputs (counters possible) 0//3 D5 D6 binary inputs 5 6 Q Q relay outputs 70 73 Y Y8 8 universal outputs STOP Caution! Observe the technical data for the relay outputs Local installation regulations must be observed Pin layout Pin Code Description Tool socket Standard RJ45 tool socket for LO devices 345678 306Z0 LO, Data A (CLA) LO, Data B (CLB) 3 0, D 4 /Plus 5 Unoccupied 6 Unoccupied 7 CO/TxD 8 CO/RxD 0/4 Building Technologies PXC36-S, PXC5 Compact automation stations CA9en_0 Building Automation 009006

Connection diagrams Peripheral supply from system transformer Active and passive sensors 0 003 A en 00 0 B B Passive sensors eg QA (i000) Active sensors eg QF (humidity) TE 0 X X agnetic valves 0 0033E 00 0 agnetic valves eg 3P +Z eg X46 3 4 3 0 () (L) Y Y TE 0 Y otorized valves 0 00334E 00 0 otorised valves 0 Y TE 0 Y Building Technologies PXC36-S, PXC5 Compact automation stations CA9en_0 Building Automation 009006 /4

Damper actuators 0 00335E 00 0 Damper actuators BB6E TE 0 8 4 5 Y Peripheral supply from separate transformer agnetic valves (example) 0 0034E 00 0 agnetic valves eg 3P +Z eg X46 3 4 0 () (L) Y 3 Y TE 0 X X 0 0 Y AC 30 V L Connecting the room units PPS 4 3 C C+ CP CP+ R 0045 R Automation station ax 5 room units (parallel) CP CP+ 4 3 C C+ CP CP+ R 4 3 C C+ CP CP+ R3 PPS Twisted pair bus cable Reversible polarity Cable length, see "Technical data" /4 otes The room units are connected in parallel (max five devices) To distinguish between them, they can be addressed by use of jumpers (address plug on the printed circuit board) The factory-setting is Address Building Technologies PXC36-S, PXC5 Compact automation stations CA9en_0 Building Automation 009006

Dimensions All dimensions in mm 8 A 8 00336 5 76 5 5 00337 A = PXC36-S: 70 PXC5: 343 Building Technologies PXC36-S, PXC5 Compact automation stations CA9en_0 Building Automation 009006 3/4

4/4 00-006 Siemens Switzerland Ltd Subject to changes Building Technologies PXC36-S, PXC5 Compact automation stations CA9en_0 Building Automation 009006