Installation and Operation Manual DPC1

Similar documents
Installation and Operation Manual SPC1

icon Series Controls

ICON SERIES IDRIVE. Intelligent Constant Pressure. Water Supply Controller User Manual. idrive

Wise HP33 THREE PHASE HIGH PRECISION AVR SURVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

ICON SERIES ipool. Swimming Pool Pump Controller. User Manual

User Manual. Solar Inverter for Water Pump

Sidewinder Pumps Inc. AC Timer/Controller

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.

User Manual. 2.2KW/7.5KW/11KW Solar Inverter for Water Pump. Version: 1.8

TPE, TPED Series 2000

Chore-Tronics IDM Board Instruction

Pump control box without probe

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

P216. Condenser fan speed controller. Product bulletin. Features

User Manual. 2.2KW LS (Low PV Input Range) Solar Inverter for Water Pump. Version: 1.1

Supplementary operating instructions for your air curtain system Controller TMC 500

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL

Model HM-535 Power Supply Installation and Service Instructions

99 Washington Street Melrose, MA Phone Toll Free Visit us at

MOBILE CONNECTOR - GEN 2 OWNER'S MANUAL

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

Valid for item nos.: (1-zone) (2-zone) (4-zone) (6-zone) HPS-C-Slot Hotrunner controllers Operating manual

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

R-LB R-LX Series Installation, Operation & Maintenance Manual

APPLICATION CONTROL GUIDELINES. IntelliROL Power Supply PN Revision Date: March 15, 2017

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:

INTRINSICALLY SAFE DUPLEXER PROTECTION. ELECTRONICS, INC Vulcan Road Apopka, Florida MOTOR INSTRUCTION MANUAL

LCD LCDS LCDRI CONTROLLER OPERATING MANUAL

SOLARIMMERSION IV Advanced Installation Manual v1.9

BCM2 Series Branch Circuit Monitors Quick Setup Guide

EX-RC1 Remote I/O Adapter

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A

Sidewinder Pumps Inc. AC C1D2 Timer/Controller

ATS CONTROLLER [ ACD-III ], [ ACD-III-C ] User s Manual. O-Sung Electric Machinery Co., Ltd.

EX-RC1 Remote I/O Adapter

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

H704-42(H)(E), H704-42/1(H)(E)

MAKING MODERN LIVING POSSIBLE. Installation Guide. Twin Kit 086L

TVAC25100 TVAC25110 User manual

User manual. TRIOU(Temperature Remote I/O Unit) Before using the product, be sure to read Safety Cautions, and use exactly as described.

Carbon Monoxide Sensor - ModBus

Instructions for use:

Quick Start Installation and User Manual

TO AVOID FIRE, SHOCK, OR DEATH; SHUT OFF POWER SUPPLY AT THE CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING.

I/O module (Expansion module)

Installation, Operation and Maintenance Manual

PRODUCT MANUAL SMOKE-1500 ENGLISH. Version: 1.0

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

Three-Phase Solar Pump Controller 1.5 kw 380V User Manual

RTD-W Installation Instructions

Instructions for use:

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. Phone: (407) Fax: (407) Vulcan Road Apopka, Florida 32703

EATON 5S 850/1200/1600

GRUNDFOS INSTRUCTIONS. Control MPC. Installation and operating instructions

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

Operating Manual LF1-LF4 i

Table of Contents. 3.1 Front/Rear Panel and User Interface Front Panel Rear Panel User Interface...

[ ACD-NA ] User s Manual. O-Sung Electric Machinery Co., Ltd. 136, Hataemal-gil, Wollong-Myeon Paju-si, Gyeonggi-do, Korea

Installation Manual. 1.Included Accessories. System Controller SC-201-6M INT. Requests to Installers *SHA8754 C*

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

EX-RC1 Remote I/O Adapter

Operating instructions. Switching amplifier DN0210 DN / / 2015

INSPECTION CAMERA MODEL NO: CIC2410 OPERATION & SAFETY INSTRUCTIONS PART NO: GC0116

General Warranty. For more details, please refer to the user manual on the supplied CD, it can also be downloaded at

INSTALLATION INSTRUCTIONS MBPEFY Series Mixing Box for Mitsubishi PEFY Series Units. Before Starting Installation Warning. Installation Instructions

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

User Manual. Item no.: Otto Graf GmbH Carl-Zeiss-Str. 2-6 Tel.: +49(0) Kunststofferzeugnisse D Teningen Fax: +49(0)

MicroTech III Applied Terminal Systems BACnet MS/TP Communication Module

Operating instructions. Speed monitor D / / 2014

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

Autoranging True RMS Multimeter User Manual

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

w w w. p r o l i g h t. c o. u k STAGE PAR 64

KOBOLD PDA Series Digital Pressure Transmitter

CoolPlug CooLinkHub HVAC Bridge. Quick Installation Guide

Quick Start Guide TS A

Procon A1M. INSTALLATION MANUAL Version MITSUBISHI ELECTRIC FOR INSTALLERS

ALPHA Automated Transfer Switch Operating Manual. Rev 1.21 The original of this document is drawn up in English language

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

DPC Warning. ! Do not pull the cable. Water Pump Digital Pressure Controller Installation and Operation Manual.

Industrial motor controller for brushed DC motors 24 VDC

EPS Power Supply

Installation and Operation Manual. ETV Platinum Plus. Electronic Tempering Valve with Safeguard WARNING

MU110-6U. Analog output module 6 channel. User guide

Installation Instructions

SMPT Solar Pump Controller. User Manual

Table of Contents. Automatic Transfer Switch. User Manual ATS-16A/20A/30A/32A

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

Blitzer Strobe. User Manual. Order code: EQLED366

AP Series Variable Frequency Drives Operation & Installation Manual

w w w. p r o l i g h t. c o. u k Quad Par 64 (Order code: LEDJ46 - Black) (Order code: LEDJ47 - Polished) USER MANUAL

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

UNIT CONTROLLER 7 (UC7) Operation & Installation. Hydronic Units

Transient Fault Location for Energized Dedicated Circuit Breakers. TFT100 User Manual. Toll Free:

Transcription:

Installation and Operation Manual DPC1 BIA-DPC1 rev 5 Page 1

TABLE OF CONTENTS Page QUICK GUIDE DRAINAGE PUMPS FLOATS CONNECTED TO PANEL 4-5 QUICK GUIDE DRAINAGE PUMPS FLOATS CONNECTED TO PUMPS 6-7 QUICK GUIDE PRESSURE BOOSTING 8-9 QUICK GUIDE TRANSFER 10-11 QUICK GUIDE HOT WATER CIRCULATION 12-13 1.0 INTRODUCTION 1.1 Applications 15 1.2 Technical parameters and features 15 1.3 Meanings of the icons shown on the LCD 17 2.0 GENERAL 2.1 Electrical connection to the power supply and pump 18 2.2 Connections for pump over temperature protection (where supplied) 19 2.3 Installing float switches and probes 19 3.0 INSTALLATION DRAINAGE 3.1 Function switch setting 20 3.2 Diagrams for drainage by liquid level through float switches or probes 21 4.0 INSTALLATION DRAINAGE WITH AUTOMATIC PUMPS 4.1 Function switch setting 25 4.2 Diagram for drainage by liquid level 26 Cont... BIA-DPC1 rev 5 Page 2

TABLE OF CONTENTS cont. 5.0 INSTALLATION BOOSTING 5.1 Function switch setting 28 5.2 Diagrams for boosting by liquid level through float switches or probes 29 6.0 INSTALLATION TRANSFER 6.1 Function switch setting 33 6.2 Diagrams for transfer by liquid level through float switches or probes 34 7.0 INSTALLATION TRANSFER HOT WATER CIRCULATION 7.1 Function switch setting 37 7.2 Diagrams for transfer by liquid level through float switches or probes 38 8.0 OPERATION 8.1 Parameter calibration and erasing 39 8.2 Switching to AUTO mode 40 8.3 Switching to MANUAL mode 40 8.4 Alarm Test and MUTE 40 8.5 Pump protection 40 8.6 Last five failure record 41 8.7 Pump accumulated running time 41 8.8 Pump disable 42 9.0 COMMUNICATION LINK 42 9.1 Basic Function 42 9.2 Special application 43 9.3 Technical parameters 43 10.0 TROUBLE SHOOTING GUIDE 44 BIA-DPC1 rev 5 Page 3

DPC1 QUICK GUIDE DRAINAGE PUMPS FLOATS CONNECTED TO PANEL SET THE DIP SWITCHES ON THE INSIDE OF THE DOOR DO NOT REMOVE BRIDGES BETWEEN TERMINALS 9&11 AND 10&12 BIA-DPC1 rev 5 Page 4

DPC1 QUICK GUIDE DRAINAGE PUMPS FLOATS CONNECTED TO PANEL CALIBRATION TURN MCB ON SWITCH TO MANUAL PRESS MODE AND STORE AT THE SAME TIME FOR 5 SEC CALIBRATE PUMP A PRESS ASTART THEN AFTER PUMP RUNNING FOR 10 SECONDS PRESS STORE CALIBRATE PUMP B PRESS BSTART THEN AFTER PUMP RUNNING FOR 10 SECONDS PRESS STORE SWITCH TO AUTO PRESS MODE BIA-DPC1 rev 5 Page 5

DPC1 QUICK GUIDE DRAINAGE PUMPS FLOATS CONNECTED TO PUMPS SET THE DIP SWITCHES ON THE INSIDE OF THE DOOR INSTALL EXTRA JUMPERS DO NOT REMOVE BRIDGES BETWEEN TERMINALS 9&11 AND 10&12 BIA-DPC1 rev 5 Page 6

DPC1 QUICK GUIDE DRAINAGE PUMPS FLOATS CONNECTED TO PUMPS CALIBRATION TURN MCB ON SWITCH TO MANUAL PRESS MODE AND STORE AT THE SAME TIME FOR 5 SEC CALIBRATE PUMP A PRESS ASTART THEN AFTER PUMP RUNNING FOR 10 SECONDS PRESS STORE CALIBRATE PUMP B PRESS BSTART THEN AFTER PUMP RUNNING FOR 10 SECONDS PRESS STORE SWITCH TO AUTO PRESS MODE BIA-DPC1 rev 5 Page 7

DPC1 QUICK GUIDE PRESSURE BOOSTING SET THE DIP SWITCHES ON THE INSIDE OF THE DOOR DO NOT REMOVE BRIDGES BETWEEN TERMINALS 9&11 AND 10&12 INSTALL EXTRA JUMPER BIA-DPC1 rev 5 Page 8

DPC1 QUICK GUIDE PRESSURE BOOSTING CALIBRATION TURN MCB ON SWITCH TO MANUAL PRESS MODE AND STORE AT THE SAME TIME FOR 5 SEC CALIBRATE PUMP A PRESS ASTART THEN AFTER PUMP RUNNING FOR 10 SECONDS PRESS STORE CALIBRATE PUMP B PRESS BSTART THEN AFTER PUMP RUNNING FOR 10 SECONDS PRESS STORE SWITCH TO AUTO PRESS MODE BIA-DPC1 rev 5 Page 9

DPC1 QUICK GUIDE TRANSFER SET THE DIP SWITCHES ON THE INSIDE OF THE DOOR MOVE JUMPER FROM 3&5 TO 4&6 DO NOT REMOVE BRIDGES BETWEEN TERMINALS 9&11 AND 10&12 BIA-DPC1 rev 5 Page 10

DPC1 QUICK GUIDE TRANSFER CALIBRATION TURN MCB ON SWITCH TO MANUAL PRESS MODE AND STORE AT THE SAME TIME FOR 5 SEC CALIBRATE PUMP A PRESS ASTART THEN AFTER PUMP RUNNING FOR 10 SECONDS PRESS STORE CALIBRATE PUMP B PRESS BSTART THEN AFTER PUMP RUNNING FOR 10 SECONDS PRESS STORE SWITCH TO AUTO PRESS MODE BIA-DPC1 rev 5 Page 11

DPC1 QUICK GUIDE HOT WATER CIRCULATION SET THE DIP SWITCHES ON THE INSIDE OF THE DOOR DO NOT REMOVE BRIDGES BETWEEN TERMINALS 9&11 AND 10&12 BIA-DPC1 rev 5 Page 12

DPC1 QUICK GUIDE HOT WATER CIRCULATION CALIBRATION TURN MCB ON SWITCH TO MANUAL PRESS MODE AND STORE AT THE SAME TIME FOR 5 SEC CALIBRATE PUMP A PRESS ASTART THEN AFTER PUMP RUNNING FOR 10 SECONDS PRESS STORE CALIBRATE PUMP B PRESS BSTART THEN AFTER PUMP RUNNING FOR 10 SECONDS PRESS STORE SWITCH TO AUTO PRESS MODE BIA-DPC1 rev 5 Page 13

Conventions used in this manual. In the manual the following symbols will be used: Generic danger. Failure to comply with the safety regulations that follow can irreparably damage the controller or equipment. Electric shock risk. Failure to comply with the safety regulations that follow can cause death or serious injury. WARNINGS Read this manual carefully before any operation. Please keep this manual for future use. WARNING!! 1. Installation must be carried out by a suitably qualified electrician. 2. Before carrying out any installation or maintenance operation, controller must be disconnected from the power supply. 3. Do not open the cover during running the controller. 4. Do not splash water or other liquid over the controller. 5. Do not allow children or infirm persons to operate the control. 6. Qualified electrician is to correctly size and install circuit breakers to protect power supply. CAUTION!! 1. The electrical and hydraulic connections must be carried out by competent, skilled, qualified personnel. 2. Never connect AC power to the output terminals. 3. Ensure the pump and controller characteristics match. 4. Do not install the controller in the following conditions: a. Vibration and mechanical shock. b. Corrosive gasses and liquids. c. Extreme heat and cold, operating range -25 o C - +55 o C. d. Salt mist corrosion. e. Rain and moisture. f. Flammable materials, solvents. BIA-DPC1 rev 5 Page 14

1.0 Introduction Thank you for choosing a Bianco Icon Series Intelligent Pump Controller. The Intelligent Pump Controller model is an easy to use, programmable controlling and protection device for direct start, single phase pumps with output power from 0.37kW 2.2kW. The Controller has many operation modes by adopting different electrical installations. Important features that distinguish the Bianco Icon Series Intelligent Pump Controllers from some other controllers are the push button calibration of overload and ability for dry run protection without float switches or probes. 1.1 Applications The Controller is useful in all cases where there is the need to control and protect single pump installations managing the automatic operation by a variety of switching methods. Typical usage scenarios include: Stormwater Sewage Booster sets Rainwater reuse Irrigation Water supply 1.2 Technical parameters and features Built in function switch for o Drainage by liquid level control through float switches or probes o Boosting water supply by pressure control through pressure switch and tank o Transfer water by liquid level control through float switches and probes Dry run protection without float switches or probes Auto/Manual switch Dynamic LCD displaying pump running state Protect the pump against many faults Push button calibration Pump accumulative running time Last five fault record RS485 communication Starts and stops the pump in accordance with liquid levels and pressure settings BIA-DPC1 rev 5 Page 15

The following chart shows main technical parameters for the Controller DPC1 Main technical characteristic Control characteristic Control method Liquid level control characteristic Pressure control characteristic Main technical data Rated output power Rated input voltage Trip response time of overload Trip response time of open phase Trip response time of short circuit Trip response time of under/over voltage Trip response time of dry run Recovery time of over load Recovery time of under/over voltage Recovery time of dry run Trip voltage of over voltage Trip voltage of under voltage Liquid level transfer distance maximum Protection functions Main installation data Working temperature Working humidity Degree of protection Install position Unit dimensions (L x W x H) RS485 technical data Physical interface Baud rate Protocol type Double liquid level control pressure control Manual/Auto pulse electrode probe and float switch pressure switch and pressure tank 0.37 2.2 kw (0.5 3.0 hp) 240V 5 sec - 5 min < 2 sec < 0.1 sec < 5 sec 6 sec 30 min 5 min 30 min 115% of rated input voltage 80% of rated input voltage 1000m Dry run Over load Transient voltage Under voltage Over voltage Pump stalled Short circuit -25 to +55 deg C 20% to 90% Relative Humidity, non-condensing IP54 Vertical 30.2 x 24.0 x 12.0 cm RS485 Bus Interface: asynchronous semi duplex 1200,2400,4800,9600 bps (default 9600bps) MODBUS protocol (RTU) BIA-DPC1 rev 5 Page 16

1.3 Meanings of the icons shown on the LCD. Icon Meaning / Description pump parameter configuration icon, when this icon appears, pump control box is parameter setting time displaying icon, when this icon appears, it means pump control box is displaying some parameter of time, eg: pump accumulated running time (unit: hour); counting down etc pump fault icon, when this icon appears, it means pump control box is displaying some fault information network connection error icon, when this icon appears, it means there is no network connections or network connection error between pump control box and SC(slave controller) or computer V M S H network normal connection icon, when this icon appears, it means the network connection between pump control box and SC (slave controller) or computer is normal voltage minute second hour % percent A ampere pump running pump stopped low pressure or lack of pressure in the pipeline or pressure tank high pressure or full of pressure in the pipeline or pressure tank pump A pump B (for dual pump controllers) BIA-DPC1 rev 5 Page 17

2.0 GENERAL 2.1 Electrical connection to the power supply and pump Main Circuit Breaker DANGER. Electric shock risk. Before carrying out any installation or maintenance operation, the control panel should be disconnected from the power supply and one should wait at least 2 minutes before opening the control panel. Never connect AC power to output L and N terminals. Ensure the motor, controller and power specifications match. The electrical and hydraulic connections must be carried out by competent, skilled, qualified personnel. Other terminals. Terminals 7 and 8 Terminals 15 and 16 MODBUS communication to Slave Controller or BMS N.O. close on fault Terminals 9 and 11 and 10 and 12 for connection to motor thermal protection (microtherms) where available. If not available leave jumper wires in. BIA-DPC1 rev 5 Page 18

2.2 Connections for pump over temperature protection (where supplied with pump). Jumper Leads Note: to realize the pump motor winding over temperature protection, it requires that there must be over-temperature switches embedded in the pump motor winding (microtherms as fitted to Zenit 3ph pumps 2.2 kw or greater). To utilise the pump s over temperature protection connect the pump s microtherm leads to terminals 9 and 11, 10 and 12 and remove the jumper. Note: if the pump is without over temperature switch, please use jumper to connect terminals 9 and 11, 10 and 12. 2.3 Installing float switches and probes. Float switch installation. Do not encase sensor leads, float switches or signal cables in metal pipes. Use PVC or PE tubing. Liquid probe installation. In event of high risk of electrical storms (lightning) or when liquid medium in sump, well or tank is very dirty, it is recommended to use float switches. BIA-DPC1 rev 5 Page 19

3.0 INSTALLATION DRAINAGE PUMPS FLOATS CONNECTED TO PANEL 3.1 Function switch setting - DRAINAGE Installers can set the function switch to meet different applications. Before setting the function switch, the control panel should be disconnected from the power supply. After completing the setting, apply power to the control panel and observe the application sign displayed on the LCD conforming to the DRAINAGE symbol. MCB DRAINAGE SETTING SWITCHES DOWN DRAINAGE SYMBOL BIA-DPC1 rev 5 Page 20

3.2 Electrical connections for DRAINAGE PUMPS FLOATS CONNECTED TO PANEL 3.2.1 Drainage by liquid level control through float switches or probes Note: for 4 float switch installation connect float switch A (pump off) to terminals 1 and 3, float switch B (1 st pump on) to terminals 1 and 5, float switch C (2 nd pump on) to terminals 2 and 4 and float switch D (alarm) to terminals 2 and 6. BIA-DPC1 rev 5 Page 21

3.2.2 Drainage by liquid level control through float switches or probes (cont) Note: for 4 float switch installation connect float switch A (pump off) to terminals 1 and 3, float switch B (1 st pump on) to terminals 1 and 5, float switch C (2 nd pump on) to terminals 2 and 4 and float switch D (alarm) to terminals 2 and 6. BIA-DPC1 rev 5 Page 22

3.2.3 Drainage by liquid level control through float switches or probes (cont) BIA-DPC1 rev 5 Page 23

Stop condition Liquid level in the sump is reaches probe 2, (float switch A down) the control panel will stop the pump. Start condition Liquid level in the sump reaches probe 3, (float switch A up) the control panel will run a pump. Control panel will alternate the pumps when the liquid level varies between probe 2 and probe 3 (float switch A up and down). 2 nd pump start condition Liquid level in the sump reaches probe 4, (float switch B up) the control panel will run the second pump. Pumps run simultaneously until liquid level reaches probe 2, (float switches A and B down). Alarm condition While pumping, if the liquid level rises in the sump to probe 5, (float switch C up), the control panel will sound the alarm to warn the user to take further action. Meanings of the messages & graphic shown on the LCD screen BIA-DPC1 rev 5 Page 24

4.0 INSTALLATION DRAINAGE PUMPS FLOATS CONNECTED TO PUMPS 4.1 Function switch setting DRAINAGE WITH AUTOMATIC PUMPS Installers can set the function switch to meet different applications. Before setting the function switch, the control panel should be disconnected from the power supply. After completing the setting, apply power to the control panel and observe the application sign displayed on the LCD conforming to the DRAINAGE symbol. MCB DRAINAGE SETTING FOR AUTOMATIC PUMPS DRAINAGE SYMBOL BIA-DPC1 rev 5 Page 25

4.2 Electrical connections DRAINAGE PUMPS FLOATS CONNECTED TO PUMPS 4.2.1 Drainage by liquid level control. Note: for drainage with automatic pumps, floats A & B are not used and terminals 1, 3, 5 and 2,4 are bridged. Note: for 3 wire floats use black and brown wires. Terminate blue wire with closed end connector. Alarm float C connected to terminals 2 and 6. If the system activates the high level alarm connected to the control panel the second pump will start and the alarm will activate until the high level float deactivates. If a pump fail situation is detected then the pump will switch to the second pump. Warning DRY RUN Protection not active in Drainage with Automatic Pump Mode. High Level Alarm Delay High Level Alarm delayed by 15 minutes after activation of High Level Float to allow 2 nd Pump to turn on and assist with pump out. Note, For 30 minutes after High level Alarm activated, both pumps work concurrently. BIA-DPC1 rev 5 Page 26

Stop condition Liquid level in the sump is below automatic pump float switch off position which will stop both pumps. Start condition The control panel alternates power supply between pumps every 240 hours. When liquid level in the sump is above the automatic pump float switch on position, the pump that is being supplied power will run. Alarm condition While pumping, if the liquid level rises in the sump to float switch C up, the control panel will start the second pump and will sound the alarm to warn the user to take further action. Meanings of the messages & graphic shown on the LCD screen BIA-DPC1 rev 5 Page 27

5.0 INSTALLATION - BOOSTING 5.1 Function switch setting - BOOSTING Installers can set the function switch to meet different applications. Before setting the function switch, the control panel should be disconnected from the power supply. After completing the setting, apply power to the control panel and observe the application sign displayed on the LCD conforming to the BOOSTING symbol. MCB BOOSTING SETTING SWITCHES UP BOOSTING SYMBOL BIA-DPC1 rev 5 Page 28

5.2 Electrical connections for BOOSTING applications. 5.2.1 Water supply by pressure control through pressure switch and tank. BIA-DPC1 rev 5 Page 29

5.2.2 Water supply by pressure control through pressure switch and tank (cont) BIA-DPC1 rev 5 Page 30

5.2.3 Water supply by pressure control through pressure switch and tank (cont) BIA-DPC1 rev 5 Page 31

Normal demand Pressure in the pipeline is lower than the setting of pressure switch B, control box will order single pump to run; pressure in the pipeline reaches the setting of pressure switch B, single pump stops running; control box will alternate double pumps running automatically when pressure in the pipeline varies in the range of pressure switch B Extra demand Single pump is running, pressure in the pipeline still decrease to the setting of pressure switch A, control box will order another pump to run simultaneously, till pressure in the pipeline reaches the setting of pressure switch B, double pumps will not stop running; Note: pressure switch should be N/C, close on pressure drop. Note: Pressure switch A = Low Pressure Switch, Pressure switch B = High Pressure Switch Meanings of the messages & graphic shown on the LCD screen BIA-DPC1 rev 5 Page 32

6.0 INSTALLATION - TRANSFER 6.1 Function switch setting - TRANSFER Installers can set the function switch to meet different applications. Before setting the function switch, the control panel should be disconnected from the power supply. After completing the setting, apply power to the control panel and observe the application sign displayed on the LCD conforming to the TRANSFER symbol. MCB TRANSFER SETTING TRANSFER SYMBOL BIA-DPC1 rev 5 Page 33

6.2 Electrical connections for TRANSFER applications. 6.2.1 Water supply by liquid level control through float switches or probes. BIA-DPC1 rev 5 Page 34

6.2.2 Water supply by liquid level control through float switches or probes (cont) BIA-DPC1 rev 5 Page 35

Normal demand Liquid level in the water storage tank is lower than Probe 1 # (float switch A: Down level), control box will order single pump to run; Liquid level reaches probe 4 # (float switch A: Up level), single pump stops running; control box will alternate double pumps running automatically when liquid level varies from Probe 1# & Probe 4#, (Float Switch A: Down level Up level Down level) Extra demand when single pump is running, liquid level is still decreasing to Probe 2# (Float Switch B: Down level), control box will order another pump to run simultaneously, until liquid level reaches Probe 4# (Float Switch A & B: Up level), double pumps will not stop running; Meanings of the messages & graphic shown on the LCD screen BIA-DPC1 rev 5 Page 36

7.0 INSTALLATION TRANSFER HOT WATER CIRCULATION 7.1 Function switch setting TRANSFER HOT WATER CIRCULATION Installers can set the function switch to meet different applications. Before setting the function switch, the control panel should be disconnected from the power supply. After completing the setting, apply power to the control panel and observe the application sign displayed on the LCD conforming to the TRANSFER symbol. MCB TRANSFER SETTING FOR HOT WATER CIRCULATION TRANSFER SYMBOL BIA-DPC1 rev 5 Page 37

7.2 Electrical connections for TRANSFER HOT WATER CIRCULATION applications. 7.2.1 Hot Water Circulation with or without thermostat. The control panel alternates power supply between pumps every 240 hours. A thermostat can be wired to terminals 2 and 4 for automatic operation on temperature. BIA-DPC1 rev 5 Page 38

8.0 OPERATION 8.1 Parameter calibration and erasing. To achieve best level of protection of the pump, it is essential that parameter calibration be done immediately after successful pump installation or pump maintenance. Setting the parameter calibration. Pump/s must be able to pump water to enable correct calibration. If pumps are calibrated without water, overload and pump stalled errors may occur later. If calibration is required without water, please contact White International for advice. Press the MODE key to switch to manual state. If the control panel is locked press MODE and STORE keys at the same time to unlock and go into manual mode. Make sure that the pump is not running and LCD screen is displaying: Press the A START key to run pump A, confirm the pump and all pipe network is in normal working state (including voltage, amps etc) with LCD screen displaying: Press the STORE button. The control panel makes a beep and a countdown starts with the LCD displaying: Control now counts down from 5 seconds. The pump stops running and parameter calibration is completed with LCD displaying: Press the B START key to repeat calibration for pump B. BIA-DPC1 rev 5 Page 39

Erasing former parameter. When pump is reinstalled after maintenance or a new pump is installed, user must erase the former calibration and a new calibration must be done. Erasing the parameter calibration. Press the MODE key to switch to manual state. If the control panel is locked press MODE and STORE keys at the same time to unlock and go into manual mode. Make sure the pump is not running and LCD is displaying: Press the A STOP key for 30 seconds; the control panel makes a beep sound, and the control panel recovers the default factory setting and the LCD displays: with Pump No Calibration flashing. Repeat for pump B by using the B STOP key for 30 seconds. 8.2 Switching to AUTO mode. To switch between MANUAL and AUTO mode press MODE. AUTO mode automatically locks control panel. Under auto state the control panel will run or stop the pump according to the signal from the liquid level probe or float switch. Note: under auto state, if the pump is running and user wants to stop the pump, press the MODE key to switch to manual state and the pump stops. Note: under auto state, if the input power is cut off and the recovers, the control panel will enter operating state after 10 seconds countdown Note: no matter if the control panels is under auto or manual state, if the input power is cut of and recovers again, the control panel will resume its operation in the same state as before the power being cut off. 8.3 Switching to MANUAL mode. To switch between AUTO and MANUAL model press MODE and STORE keys at the same time for 5 seconds to unlock and go into MANUAL mode. Press the START key to start the pump and the STOP to stop the pump. 8.4 Alarm Test and Mute. Under MANUAL mode and pump/s not operating press STORE for 3 seconds to test the alarm. At any time press ASTOP to mute the alarm. 8.5 Pump Protection During pump running, if dry run, overload, over voltage, etc failures occur, the control panel will immediately shut down the pump running and automatically execute a check for restarting conditions after a built in time delay has elapsed. The control panel will not recover automatically until all the abnormal situations have been cleared. If pump stalled, open phase or other serious failure has occurred, pump user must immediately check pump and motor. BIA-DPC1 rev 5 Page 40

8.6 Last five failure record The control panel can memorize the last five failures of pump, so it is very convenient for the users to analyse the pump running conditions. Displaying the last five failure record. Press the MODE key to switch to manual state, make sure the pump is not running and the LCD screen is displaying: Hold pressing A STOP key and press MODE key, the control panel makes a beep sound and displays pump A failure record. Press the A STOP key to quit the failure record display; Failure Icon Note: the failure displayed above is PUMP STALLED. Repeat for pump B by using B STOP key. 8.7 Pump accumulative running time The control panel can memorise how many hours of pump running, so it is very convenient for the pump user to analyse the pump running conditions and do maintenance. Displaying the pump accumulative running time. Press the MODE key to switch to manual state, make sure that the pump is not running and the LCD screen is displaying: Hold pressing the STORE key and press the A STOP key. The control panel makes a beep sound and displays the accumulative run time. BIA-DPC1 rev 5 Page 41

The pump has run for 23 hours. Press the A STOP key to quit the accumulative running time display. Repeat for pump B by using B STOP key. 8.8 Pump disable. To disable a pump independently, in AUTO mode press MODE and A STOP or B STOP at the same time for 2 seconds. A PUMP and MANUAL flashing means pump A is disabled. To restore the pump, in AUTO mode press MODE and A START or B START at the same time for 2 seconds. 9.0 Communication link. The control panel has communication interface, that along with the optional Slave Controller, users can realise a long distance monitoring function. This function applies to where the control panel is installed in the basement or pumping room, but users require to monitor and control the pump on the ground or in a control room. BIA-DPC1 rev 5 Page 42

9.1 Basic function. Slave Controller (SC) with communication interface can realize long distance monitoring. In the control room, users can realize all the functions of the master control panel through the SC, except parameter calibration and adjusting. 9.2 Special application. As adopting communication interface, the wire communication distance is less than 1200 metres. For those installation environments which require a longer distance communication, i.e., mine, water tower, across railway road and bridge etc., users can adopt RS485 extender, wireless communication or GSM. Please contact the manufacturer for more information. 9.3 Technical parameters. The following chart shows main technical parameters of communication between the control panel and the slave controller. Main technical data Physical interface RS485 Bus Interface: asynchronous semi duplex Data format 1 start bit, 8 data bit, 1 stop bit, no verify 1 start bit, 8 data bit, 2 stop bit, no verify Default: 1 start bit, 8 data bit, 1 stop bit, no verify Baud rate 1200,2400,4800,9600 bps (default 9600bps) Communication address Setting range of controller address: 1-126 127: broadcast address, host computer broadcasting, slave machine response forbidden Protocol type MODBUS protocol (RTU) Rated input voltage for SC AC 240V/50Hz, single phase Main installation data Wire communication distance 1200 metres max by shield twisted pair cable (STP) for RS485 & CAN 5000 metres max by STP and RS485 extender STP STP-120U one pair 20AWG for RS485 & CAN RS485 extender 5000 metres (9600bps) BIA-DPC1 rev 5 Page 43

10.0 Trouble shooting guide Fault Message Possible Cause Solutions flashing of UNDER V the real running voltage is lower than the report low line voltage to the power calibrated voltage, pump is in under voltage supply company protection state Control will attempt to restart the pump every 5 min until line voltage is restored to normal flashing of OVER V the real running voltage is higher than the report low line voltage to the power flashing of OVER LOAD calibrated voltage, pump is in over voltage protection state the real running ampere is higher than the calibrated running ampere, pump is in over load protection state pump damaged supply company Control will attempt to restart the pump every 5 min until line voltage is restored to normal Control will attempt to restart the pump every 30 min until running ampere is restored to normal inspect pump flashing of parameter calibration not completed refer to parameter calibration setting PUMP NO CALIBRATION flashing of DRY RUN liquid level in the well / sump is below the pump intake, pump stops running Control will attempt to restart the pump every 30 min until liquid level is above the pump intake flashing of pump running amps exceeded cut off power supply and repair or PUMP STALLED normal rum amps by more than 200% replace pump flashing of pump starts more than 5 times per Check pressure tank precharge REPEATED START minute Check pressure tank bladder Check pressure switch settings Check pressure switch for defects no communication link between SC / computer and Control connect the Control to SC / computer to realize long distance monitoring BIA-DPC1 rev 5 Page 44

BIA-DPC1 rev 5 Page 45

BIA-DPC1 rev 5 Page 46